[Objective] This study was conducted to investigate the effects of Penicillium spp. and Trichoderma spp. on the growth of Pleurotus ostreatus (oyster mushroom) and to screen effective disinfectants to control them a...[Objective] This study was conducted to investigate the effects of Penicillium spp. and Trichoderma spp. on the growth of Pleurotus ostreatus (oyster mushroom) and to screen effective disinfectants to control them and other pathogenic microbes. [Method] Six strains or species of Penicilliurn and Trichoderma were inocu- lated into PDA plates growing with P. ostreatus to observe the growth of their mycelia. And the inhibitory effects of hydrogen peroxide, bromogeramine bromide, 84 disinfectant, lysol, potassium permanganate, and 75% medical alcohol on Trichoderma pleuroticola, Trichoderma viride, Trichoderma harzianum, Penicillium citrinum, Penicillium thomii and Penicillium brevicompactum were detected. [Result] Confrontation test revealed that Penicillium spp. and Trichoderma spp. competed for nutrients with P. ostreatus mycelia, antagonized against the growth of P. ostreatus mycelia, invaded and twined around P. ostreatus mycelia, and also produced toxins poisoning P. ostreatus mycelia. The six disinfectants exhibited different inhibitory effects against different species of Penicillium and Trichoderma. Among them the in- hibitory effects of bromogeramine bromide against the six species of Penicillium and Trichoderma were significantly different. However, the inhibitory effects of 3% hydrogen peroxide, 84 disinfectant, 5% lysol, potassium permanganate and 75% medical alcohol were significantly different among Penicillium spp., but did not among Tri- choderma spp. [Conclusion] Bromogeramine bromide can be used to control the bacteria and fungi in mushroom production for it has significant inhibitory effects on the six species of both Penicillium and Trichoderma.展开更多
Six different kinds of non-metallic or organic disinfectants were obtained in this research study including “Neutral Electrolyzed Water”, “M22” organic disinfectant solution, Superoxy Food Wash disinfectant, Hydro...Six different kinds of non-metallic or organic disinfectants were obtained in this research study including “Neutral Electrolyzed Water”, “M22” organic disinfectant solution, Superoxy Food Wash disinfectant, Hydrogen Peroxide, Clorox Germicidal Bleach and Clidox-S. The effectiveness of these disinfectants was studied against various subtypes of avian influenza virus (AIV). The virus-disinfectant mixtures were prepared in serial dilutions of each disinfectant with a constant virus titer and incubated at ambient temperature in different time intervals for virus inactivation. The virus inactivation results were determined by virus recovery in embryonating chicken eggs. Among the six different kinds of nonmetallic disinfectants obtained for this research project, Neutral Electrolyzed Water, “M22” solution, Clorox Germicidal Bleach and Clidox-S were effectively inactivated AIV with appropriate working dilutions and reaction times. Superoxy Food Wash disinfectant and Hydrogen Peroxide were found having limited effect on virus inactivation with extended exposure times of more than 2 hours. These research findings provide scientific data to poultry industry with guidelines to select and use non-metallic organic disinfectants for poultry flock sanitation and disinfection to effectively prevent and control of avian influenza outbreaks.展开更多
Objective: Infection control protocols dictate the disinfection of dentures. There are no products available which are designed for the specific use of disinfecting dentures. The objective of this study was to investi...Objective: Infection control protocols dictate the disinfection of dentures. There are no products available which are designed for the specific use of disinfecting dentures. The objective of this study was to investigate the impact of chemical disinfectants on elastic modulus, flexural strength and color stability of denture base resins. Methods: 256 specimens from four acrylic denture base resins were manufactured. Two cold-curing denture base resins: PalaXpress (Heraeus Kulzer, Hanau, Germany), Futura Gen (Schuetz Dental, Roßbach, Germany) and two heat-curing denture base resins: Paladon 65 (Heraeus Kulzer, Hanau, Germany), FuturAcryl 2000 (Schuetz Dental, Roßbach, Germany) were used. Three chemical disinfecting agents were tested: Impresept, D050 Instru-Gen, Stammopur DR. Specimens were stored in distilled water and in chemical disinfecting agents. They were divided randomly into groups. E-Modulus and flexural strength were measured using the three-point bending test. Color changes (ΔE) were determined spectrophotometrically. Results: The disinfection agents showed no significant influence on the E-modulus compared to distilled water (Acrylic vs. distilled water from (Futura Gen) 2688.80 ± 230.78 vs. 2766.60 ± 91.22 MPa to (PalaXpress) 3004.20 ± 26.40 vs. 2851.00 ± 95.23 MPa). Flexural strength after storage in distilled water and disinfection did not differ significantly (Acrylic vs. distilled water from (Paladon65) 27.28 ± 1.30 vs. 28.42 ± 0.84 N/mm2, (p > 0.05) to (PalaXpress) 30.88 ± 0.25 vs. 29.68 ± 0.79 N/mm2, p < 0.001). Disinfection caused a significant color change with Impresept of Paladon 65 (p ≤ 0.001), FuturaAcryl 2000 with Stammopur DR and D 050 Instru-Gen (p ≤ 0.001). Conclusions: The investigated disinfection agents did not influence elastic modulus and flexural strength of denture base resins negatively. ΔE-values were in a range of 1 to 2. Thus, the detected color changes may be marginal. Clinical relevance: Single use disinfections are feasible for acrylic dentures regarding to elastic modulus and flexural strength.展开更多
The aim of the study was to determine the impact of residues of detergents and disinfectants on the results of most commonly used inhibitor tests for raw milk. Microbiological test (Delvotest SP-NT) and three rapid te...The aim of the study was to determine the impact of residues of detergents and disinfectants on the results of most commonly used inhibitor tests for raw milk. Microbiological test (Delvotest SP-NT) and three rapid tests (Charm 3 MRL BL/TET2, Charm ROSA MRL BL/TET and Penzym) were used in the study. Three concentrations (recommended by the manufacturer, 10 times lower and twice higher) of 36 detergents and disinfectants in raw milk were investigated. All methods did not detect concentrations of detergents and disinfectants of alkaline and acid origin 10 times lower than recommended by the manufacturer. 39% of the investigated substances of alkaline origin were detected by Delvotest SP-NT and Penzym;Charm tests showed non-typical results only. Delvotest SP-NT did not detect substances of acid origin;Penzym detected 50% of these substances, Charm tests showed only non-typical results. Delvotest SP-NT and Penzym appeared to be more sensitive to the substances used for teat hygiene and disinfection. The scope of rapid tests (receptor or enzymatic) does not cover the detection of detergent and disinfectant re- sidues in milk. However, according to the non-typical results of the test, it is possible to suspect the presence of these substances in milk. McNemar’s and Cochran’s Q tests were used for statistical analysis of the data.展开更多
Aim: This study aims to assess the infection risks of flashlight contamination in a stomatology hospital and compare the disinfection effectiveness of alcohol (75%) and disinfecting wipes.Background: The flashlight is...Aim: This study aims to assess the infection risks of flashlight contamination in a stomatology hospital and compare the disinfection effectiveness of alcohol (75%) and disinfecting wipes.Background: The flashlight is a basic non-critical medical device in oral and maxillofacial surgery wards. Wounds are mostly found in oral cavities;therefore, reusable flashlights may be a potential source of nosocomial infections (NIs). However, the microbial flora present in flashlights used in hospitals has not yet been explored. Methods: This study investigated the microbial contamination of 41 flashlights used in a stomatology hospital in Guangzhou in March 2016. Results: Results indicated that 75.6%(31/41) of the flashlights had microbial contamination. Gram-positive bacteria accounted for 72.7%(24/33)of the microbial groups contaminating the flashlights, and Gram-negative bacteria (21.2%, 7/33), and fungi (6.1%, 2/33) constituted the remaining contaminants. The predominantly isolated species was Staphyloccus (66.7%, 22/33), especially Staphylococcus aureus (24.2%, 8/33). Approximately 77.3%(17/22) of the types of bacteria detected in the hands were same as those in the corresponding flashlights. Both the bacterial overstandard and S. aureus detection rates of doctors' flashlights were higher than those of nurses' flashlights (16/17 vs. 14/23, 7/17 vs. 1/23, respectively) (P < 0.05). Moreover, both disinfectants performed excellently, and their eligibility rates were not significantly different (17/17 vs. 14/14) (P>0.05). Conclusion: Flashlights are potential causes of NIs. Disinfecting flashlights could be an effective and practical infection control method.展开更多
BACKGROUND Misuse of disinfectants during the coronavirus disease 2019 pandemic has led to several poisoning incidents.However,there are few clinical case reports on poisoning caused by improper mixing of household di...BACKGROUND Misuse of disinfectants during the coronavirus disease 2019 pandemic has led to several poisoning incidents.However,there are few clinical case reports on poisoning caused by improper mixing of household disinfectants.AIM To summarize the clinical characteristics and treatment effects of chlorine poisoning caused by improper mixing of hypochlorite bleach with acidic cleaning agents.METHODS We retrospectively analyzed baseline and clinical data,clinical symptoms,and treatment methods of seven patients with chlorine poisoning who were admitted to the National Army Poisoning Treatment Center.RESULTS Among the seven patients,the average poisoning time(exposure to admission)was 57 h(4-240 h).All patients were involved in cleaning bathrooms.Chest computed tomography scans revealed bilateral lung effusions or inflammatory changes in five patients.The partial pressure of oxygen decreased in six patients,and respiratory failure occurred in one.Five patients had different degrees of increase in white blood cell count.Humidified oxygen therapy,non-invasive mechanical ventilation,anti-inflammatory corticosteroids,antioxidants,and antibiotics were administered for treatment.The average length of hospital stay was 7 d(4-9 d).All seven patients recovered and were discharged.CONCLUSION Improper mixing of household disinfectants may cause damage to the respiratory system due to chlorine poisoning.Corticosteroids may improve lung exudation in severe cases,and symptomatic supportive treatment should be performed early.展开更多
To investigate the corrosion behaviors and antibacterial effects of sodium hypochlorite(NaClO)and hydrogen peroxide silver ion(HPSI)disinfectants with different concentrations against dental unit waterlines and provid...To investigate the corrosion behaviors and antibacterial effects of sodium hypochlorite(NaClO)and hydrogen peroxide silver ion(HPSI)disinfectants with different concentrations against dental unit waterlines and provide guidance and reference for the use of chemical disinfectants,polyurethane tubes were immersed in ultrapure water(control group),0.1%NaClO,0.5%NaClO,1.0%NaClO,2.5%HPSI,5.0%HPSI,and 10%HPSI solutions for 6,12,and 18 weeks.Contact angles and Fourier transform infrared spectra were detected.Surface morphologies were observed using scanning electron microscopy and antibacterial activity was evaluated using Gram-positive Staphylococcus aureus(S.aureus).The results showed that sodium hypochlorite and hydrogen peroxide silver ion disinfectants presented good antibacterial activity against S.aureus.However,sodium hypochlorite could cause serious damage to the water pipes where corrosion pits and cracks were observed,and increasing the concentration of sodium hypochlorite could accelerate the corrosion process.Hydrogen peroxide silver ion disinfectants had no obvious damage to the water pipes.Therefore,hydrogen peroxide silver ion disinfectants are recommended to use for controlling bacterial infection in dental unit waterlines which can reduce the damage to the water pipes.展开更多
Prevention of African swine fever,a disease caused by African swine fever virus(ASFV),requires maintenance of high biosecurity standards,which principally relies on disinfection.Finding the perfect disinfectant agains...Prevention of African swine fever,a disease caused by African swine fever virus(ASFV),requires maintenance of high biosecurity standards,which principally relies on disinfection.Finding the perfect disinfectant against ASFV is difficult because of the lack of relevant data.Therefore,we aimed to find the most effective disinfectant and to optimise its concentration as well as contact time to confirm the viricidal effect against ASFV in vitro.We evaluated the viricidal activity of three concentrations each of six common disinfectants against ASFV using immersion disinfection assay(IDA)and spray disinfection assay(SDA);the concentrations of these disinfectants at which complete viral inactivation occurred were almost same as the manufacturer-recommended concentrations,but the exposure times for viral inactivation are different.The following disinfectants(assay:concentration,exposure time)showed complete inactivation:iodine and acid mixed solution(IDA/SDA:0.5%,10 min);compound potassium peroxymonosulfate(IDA:0.25%,30 min;SDA:0.25%,60 min);citric acid(IDA:0.25%,60 min;SDA:0.5%,60 min);sodium dichloroisocyanurate(IDA:0.125%,60 min;SDA:0.25%,60 min);and glutaral ang deciquam(IDA/SDA:0.2%,60 min);and deciquam(IDA/SDA:0.5%,60 min).However,in the presence of organic material contamination,disinfectants did not show a marked inactivation effect.Therefore,disinfection procedures should be performed in two steps:thorough mechanical cleaning followed by application of disinfectant.In conclusion,all the tested disinfectants can inactivate ASFV;these can be used as alternative disinfectants to enhance biosecurity.展开更多
The disinfection effect of chlorine dioxide, chlorine and their mixture on heterotrophic bacteria, iron bacteria and sulfate-reducing bacteria in circulating cooling water was studied. The results of the test indicate...The disinfection effect of chlorine dioxide, chlorine and their mixture on heterotrophic bacteria, iron bacteria and sulfate-reducing bacteria in circulating cooling water was studied. The results of the test indicated that high purity chlorine dioxide was the most effective biocide in the 3 disinfectants, and with a dosage of 0.5 mg/L, chlorine dioxide could obtain perfect effect. High purity chloride dioxide could have the excellent effect with the pH value of 6 to 10, and could keep it within 72 h. Chlorine and their mixture couldn’t reach the effect of chlorine dioxide.展开更多
Monkeypox(mpox)outbreak in 2022 has caused more than 91,000 cases,has spread to 115 countries,regions,and territories,and has thus attracted much attention.The stability of poxvirus particles in the environment is rec...Monkeypox(mpox)outbreak in 2022 has caused more than 91,000 cases,has spread to 115 countries,regions,and territories,and has thus attracted much attention.The stability of poxvirus particles in the environment is recognized as an important factor in determining their transmission.However,few studies have investigated the persistence of poxviruses on material surfaces under various environmental conditions,and their sensitivity to biocides.Here,we systematically measured the stability of vaccinia virus(VACV)under different environmental conditions and sensitivity to inactivation methods via plaque assay,quantitative real‐time polymerase chain reaction(qPCR),and Gaussia luciferase(G‐luciferase)reporter system.The results show that VACV is stable on the surface of stainless steel,glass,clothing,plastic,towel,A4 paper,and tissue and persists much longer at 4℃ and?20℃,but is effectively inactivated by ultraviolet(UV)irradiation,heat treatment,and chemical reagents.Our study raises the awareness of long persistence of poxviruses in the environment and provides a simple solution to inactivate poxviruses using common disinfectants,which is expected to help the control and prevention of mpox virus and future poxvirus outbreaks.展开更多
In clinical practice,the important hygienic prevention of bacterial pathogen spread is disinfection of potentially contaminated area.Benzalkonium bromide and chlorhexidine acetate are commonly used disinfectants with ...In clinical practice,the important hygienic prevention of bacterial pathogen spread is disinfection of potentially contaminated area.Benzalkonium bromide and chlorhexidine acetate are commonly used disinfectants with a broad spectrum of antimicrobial effect.It is vital to inhibit the spread of pathogen in hospital.However,a large number of pathogens with the decreased antiseptic susceptibility have been isolated from clinical samples which showed an increased minimal inhibitory concentration(MIC)against those antiseptics.These resistant pathogens are the major causes for nosocomial crossinfections in hospital.The present study demonstrated the utility of Oxford plate assay system in determining the potential disinfectant resistance of bacteria.The microbiological assay is based on the inhibitory effect of tested disinfectants upon the strains of Staphylococcus aureus and Escherichia coli.Statistical analysis of the bioassay results indicated the linear correlation(r=-0.87-0.99,P<0.01)between the diameter of growth inhibition zone and the log dosage of the tested disinfectants.Moreover,comparison of inhibitory efficacy of benzalkonium bromide upon 29 S.aureus strains isolated from clinical samples by both Oxford plate method and broth dilution method showed that the diameter of growth inhibition zone has significantly negative correlation with the minimal inhibitory concentration(MIC)(r=-0.574,P<0.001).These results suggest that the Oxford plate is a simple and time-saving method in detecting potential clinical disinfectant resistance and its usefulness for routine surveillance of pathogenic resistance to disinfectants warrants further investigation.展开更多
Concerns about air quality in dental clinics where aerosol generation during procedures poses significant health risks,have prompted investigations on advanced disinfection technologies.This editorial describes the st...Concerns about air quality in dental clinics where aerosol generation during procedures poses significant health risks,have prompted investigations on advanced disinfection technologies.This editorial describes the strengths and limitations of ventilation and aerosol control measures in dental offices,especially with respect to the use of graphene nanocomposites.The potential of graphene nanocomposites as an innovative solution to aerosol-associated health risks is examined in this review due to the unique properties of graphene(e.g.,high con-ductivity,mechanical strength,and antimicrobial activity).These properties have produced promising results in various fields,but the application of graphene in dentistry remains unexplored.The recent study by Ju et al which was published in World Journal of Clinical Cases evaluated the effectiveness of graphene-based air disinfection systems in dental clinics.The study demonstrated that graphene-based disinfection techniques produced significant reductions in suspended particulate matter and bacterial colony counts,when co-mpared with traditional methods.Despite these positive results,challenges such as material saturation,frequency of filter replacement,and associated costs must be addressed before widespread adoption of graphene-based disinfection techniques in clinical practice.Therefore,there is need for further research on material structure optimization,long-term safety evaluations,and broader clinical applications,in order to maximize their positive impact on public health.展开更多
This manuscript features the promising findings of a study conducted by Ju et al,who used graphene nanocomposites for air disinfection in dental clinics.Their study demonstrated that,compared with conventional filters...This manuscript features the promising findings of a study conducted by Ju et al,who used graphene nanocomposites for air disinfection in dental clinics.Their study demonstrated that,compared with conventional filters,graphene nanocom-posites substantially improved air quality and reduced microbial contamination.This manuscript highlights the innovative application of graphene materials,emphasizing their potential to enhance dental clinic environments by minimizing secondary pollution.On the basis of the unique antimicrobial properties of gra-phene and the original study’s rigorous methodology,we recommend using gra-phene nanocomposites in clinical settings to control airborne infections.展开更多
Tracing the contamination origins in water sources and identifying the impacts of natural and human processes are essential for ecological safety and public health.However,current analysis approaches are not ideal,as ...Tracing the contamination origins in water sources and identifying the impacts of natural and human processes are essential for ecological safety and public health.However,current analysis approaches are not ideal,as they tend to be laborious,time-consuming,or technically difficult.Disinfection byproducts(DBPs)are a family of well-known secondary pollutants formed by the reactions of chemical disinfectants with DBP precursors during water disinfection treatment.Since DBP precursors have various origins(e.g.,natural,domestic,industrial,and agricultural sources),and since the formation of DBPs from different precursors in the presence of specific disinfectants is distinctive,we argue that DBPs and DBP precursors can serve as alternative indicators to assess the contamination in water sources and identify pollution origins.After providing a retrospective of the origins of DBPs and DBP precursors,as well as the specific formation patterns of DBPs from different precursors,this article presents an overview of the impacts of various natural and anthropogenic factors on DBPs and DBP precursors in drinking water sources.In practice,the DBPs(i.e.,their concentration and speciation)originally present in source water and the DBP precursors determined using DBP formation potential tests—in which water samples are dosed with a stoichiometric excess of specific disinfectants in order to maximize DBP formation under certain reaction conditions—can be considered as alternative metrics.When jointly used with other water quality parameters(e.g.,dissolved organic carbon,dissolved organic nitrogen,fluorescence,and molecular weight distribution)and specific contaminants of emerging concern(e.g.,certain pharmaceuticals and personal care products),DBPs and DBP precursors in drinking water sources can provide a more comprehensive picture of water pollution for better managing water resources and ensuring human health.展开更多
BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in ...BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in dental clinics by leveraging its adsorption and antibacterial properties.METHODS Patients who received ultrasonic cleaning at our hospital from April 2023 to April 2024.They were randomly assigned to three groups(n=20 each):Graphene nanocomposite material suction group(Group A),ordinary filter suction group(Group B),and no air suction device group(Group C).The air quality and air colony count in the clinic rooms were assessed before,during,and after the procedure.Additionally,bacterial colony counts were obtained from the air outlets of the suction devices and the filter screens in Groups A and B.RESULTS Before ultrasonic cleaning,no significant differences in air quality PM2.5 and colony counts were observed among the three groups.However,significant differences in air quality PM2.5 and colony counts were noted among the three groups during ultrasonic cleaning and after ultrasonic treatment.Additionally,the number of colonies on the exhaust port of the suction device and the surface of the filter were significantly lower in Group A than in Group B(P=0.000 and P=0.000,respectively).CONCLUSION Graphene nanocomposites can effectively sterilize the air in dental clinics by exerting their antimicrobial effects and may be used to reduce secondary pollution.展开更多
Sodium hypochlorite has significant potential as a sanitation solution in hard-to-reach areas.Few studies have investigated the optimal electrolysis parameters for its production with volumes greater than 1o L.This st...Sodium hypochlorite has significant potential as a sanitation solution in hard-to-reach areas.Few studies have investigated the optimal electrolysis parameters for its production with volumes greater than 1o L.This study evaluated sodium hypochlorite production through electrolysis in a 22-L prototype and identified the optimal operating parameters.Tests were performed using graphite electrodes with areas of 68.4 cm^(2) at the laboratory scale and 1865.0 cm^(2) at the prototype scale.A design for experiments with different operating times,chloride concentrations,and electric current intensities was developed.The optimal operating time,sodium chloride concentration,and current intensity at the laboratory scale were 120 min,150 g of chloride per liter,and 3 A,respectively,leading to the production of 5.02 g/L of the disinfectant with an energy efficiency of 12.21 mg of Cl_(2) per kilojoule.At the prototype scale,the maximum sodium hypochlorite concentration of 3.99 g of chloride per liter was achieved with an operating time of 120 min,a sodium chloride concentration of 100 g of chloride per liter,and a current intensity of 70 A,reaching an energy efficiency of 42.56 mg of Cl_(2) per kilojoule.In addition,this study evaluated the influences of the chloride concentration,current intensity,and operating time on the production of sodium hypochlorite at the two scales,and formulated the equations showing the trends of sodium hypochlorite production and energy efficiency in the electrochemical systems.The 22-L prototype model for production of this oxidizing substance is promising for disinfection of large volumes of water in areas that are difficult to access.展开更多
BACKGROUND Commonly used cleaning brushes in the reprocessing of flexible endoscopes often cause damage within the working channels.AIM To develop a spray flushing system to achieving effective cleaning of the working...BACKGROUND Commonly used cleaning brushes in the reprocessing of flexible endoscopes often cause damage within the working channels.AIM To develop a spray flushing system to achieving effective cleaning of the working channels while minimizing damage.METHODS This prospective study included 60 used endoscopes and 60 Teflon tubes randomly divided into a control group(n=30)and an experimental group(n=30).The material of Teflon tubes was the same as that of the endoscope working channel.Endoscopes in the control group were manually cleaned using traditional cleaning brushes,while those in the experimental group were cleaned using the newly developed spray flushing system.ATP levels,cleanliness,and microbiological testing of the working channels were measured.Additionally,Teflon tubes in the control group underwent 500 passes with a cleaning brush,while those in the experimental group were subjected to the spray flushing system,and channel damage was evaluated.RESULTS The ATP levels(RLU)in the two groups were 32.5(13-66)and 26(16-40),respectively(P>0.05).Cleanliness scores were 1.5(1-2)and 1(1-2),respectively(P>0.05).Debris was found in 73.3%of the control group,which was significantly higher than 46.7%in the experimental group(P<0.05).Microbiological tests for both groups yielded negative results.Teflon tube damage in the control group was rated at 4(4-5.25),which was significantly higher than in the experimental group 4(3-4)(P<0.01).CONCLUSION The spray flushing system demonstrated superior efficacy in removing debris and resulted in less damage to the endoscope working channels compared with traditional cleaning brushes.展开更多
Objective Chlorination is often used to disinfect recreational water in large amusement parks;however,the health hazards of chlorination disinfection by-products(DBPs)to occupational populations are unknown.This study...Objective Chlorination is often used to disinfect recreational water in large amusement parks;however,the health hazards of chlorination disinfection by-products(DBPs)to occupational populations are unknown.This study aimed to assess the exposure status of chlorinated DBPs in recreational water and the health risks to employees of large amusement parks.Methods Exposure parameters of employees of three large amusement parks in Shanghai were investigated using a questionnaire.Seven typical chlorinated DBPs in recreational water and spray samples were quantified by gas chromatography,and the health risks to amusement park employees exposed to chlorinated DBPs were evaluated according to the WHO's risk assessment framework.Results Trichloroacetic acid,dibromochloromethane,bromodichloromethane,and dichloroacetic acid were detected predominantly in recreational water.The carcinogenic and non-carcinogenic risks of the five DBPs did not exceed the risk thresholds.In addition,the carcinogenic and non-carcinogenic risks of mixed exposure to DBPs were within the acceptable risk limits.Conclusion Typical DBPs were widely detected in recreational water collected from three large amusement parks in Shanghai;however,the health risks of DBPs and their mixtures were within acceptable limits.展开更多
Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization sup...Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization supply center from January 2021 to January 2023.The work situation before January 31,2022,was classified as the control group;a routine quality control management model was implemented,and the work situation after January 31,2022,was classified as the observation group.The quality of medical device management and department satisfaction between the two groups were compared.Results:The timely recovery and supply rate,classification and cleaning pass rate,disinfection pass rate,packaging pass rate,sterilization pass rate,and department satisfaction score in the observation group were all higher than those of the control group(P<0.05).Conclusion:Implementing a refined quality control management model in the sterilization supply center can improve the quality management level of medical devices and department satisfaction and is worthy of promotion.展开更多
Since the catalytic activity of most nanozymes is still far lower than the corresponding natural enzymes,there is urgent need to discover novel highly efficient enzyme-like materials.In this work,Co_(3)V_(2)O_(8)with ...Since the catalytic activity of most nanozymes is still far lower than the corresponding natural enzymes,there is urgent need to discover novel highly efficient enzyme-like materials.In this work,Co_(3)V_(2)O_(8)with hollow hexagonal prismatic pencil structures were prepared as novel artificial enzyme mimics.They were then decorated by photo-depositing Ag nanoparticles(Ag NPs)on the surface to further improve its catalytic activities.The Ag NPs decorated Co_(3)V_(2)O_(8)(ACVPs)showed both excellent oxidase-and peroxidase-like catalytic activities.They can oxidize the colorless 3,3’,5,5’-tetramethylbenzidine rapidly to induce a blue change.The enhanced enzyme mimetic activities can be attributed to the surface plasma resonance(SPR)effect of Ag NPs as well as the synergistic catalytic effect between Ag NPs and Co_(3)V_(2)O_(8),accelerating electron transfer and promoting the catalytic process.ACVPs were applied in constructing a colorimetric sensor,validating the occurrence of the Fenton reaction,and disinfection,presenting favorable catalytic performance.The enzyme-like catalytic mechanism was studied,indicating the chief role of⋅O_(2)-radicals in the catalytic process.This work not only discovers a novel functional material with double enzyme mimetic activity but also provides a new insight into exploiting artificial enzyme mimics with highly efficient catalytic ability.展开更多
文摘[Objective] This study was conducted to investigate the effects of Penicillium spp. and Trichoderma spp. on the growth of Pleurotus ostreatus (oyster mushroom) and to screen effective disinfectants to control them and other pathogenic microbes. [Method] Six strains or species of Penicilliurn and Trichoderma were inocu- lated into PDA plates growing with P. ostreatus to observe the growth of their mycelia. And the inhibitory effects of hydrogen peroxide, bromogeramine bromide, 84 disinfectant, lysol, potassium permanganate, and 75% medical alcohol on Trichoderma pleuroticola, Trichoderma viride, Trichoderma harzianum, Penicillium citrinum, Penicillium thomii and Penicillium brevicompactum were detected. [Result] Confrontation test revealed that Penicillium spp. and Trichoderma spp. competed for nutrients with P. ostreatus mycelia, antagonized against the growth of P. ostreatus mycelia, invaded and twined around P. ostreatus mycelia, and also produced toxins poisoning P. ostreatus mycelia. The six disinfectants exhibited different inhibitory effects against different species of Penicillium and Trichoderma. Among them the in- hibitory effects of bromogeramine bromide against the six species of Penicillium and Trichoderma were significantly different. However, the inhibitory effects of 3% hydrogen peroxide, 84 disinfectant, 5% lysol, potassium permanganate and 75% medical alcohol were significantly different among Penicillium spp., but did not among Tri- choderma spp. [Conclusion] Bromogeramine bromide can be used to control the bacteria and fungi in mushroom production for it has significant inhibitory effects on the six species of both Penicillium and Trichoderma.
文摘Six different kinds of non-metallic or organic disinfectants were obtained in this research study including “Neutral Electrolyzed Water”, “M22” organic disinfectant solution, Superoxy Food Wash disinfectant, Hydrogen Peroxide, Clorox Germicidal Bleach and Clidox-S. The effectiveness of these disinfectants was studied against various subtypes of avian influenza virus (AIV). The virus-disinfectant mixtures were prepared in serial dilutions of each disinfectant with a constant virus titer and incubated at ambient temperature in different time intervals for virus inactivation. The virus inactivation results were determined by virus recovery in embryonating chicken eggs. Among the six different kinds of nonmetallic disinfectants obtained for this research project, Neutral Electrolyzed Water, “M22” solution, Clorox Germicidal Bleach and Clidox-S were effectively inactivated AIV with appropriate working dilutions and reaction times. Superoxy Food Wash disinfectant and Hydrogen Peroxide were found having limited effect on virus inactivation with extended exposure times of more than 2 hours. These research findings provide scientific data to poultry industry with guidelines to select and use non-metallic organic disinfectants for poultry flock sanitation and disinfection to effectively prevent and control of avian influenza outbreaks.
文摘Objective: Infection control protocols dictate the disinfection of dentures. There are no products available which are designed for the specific use of disinfecting dentures. The objective of this study was to investigate the impact of chemical disinfectants on elastic modulus, flexural strength and color stability of denture base resins. Methods: 256 specimens from four acrylic denture base resins were manufactured. Two cold-curing denture base resins: PalaXpress (Heraeus Kulzer, Hanau, Germany), Futura Gen (Schuetz Dental, Roßbach, Germany) and two heat-curing denture base resins: Paladon 65 (Heraeus Kulzer, Hanau, Germany), FuturAcryl 2000 (Schuetz Dental, Roßbach, Germany) were used. Three chemical disinfecting agents were tested: Impresept, D050 Instru-Gen, Stammopur DR. Specimens were stored in distilled water and in chemical disinfecting agents. They were divided randomly into groups. E-Modulus and flexural strength were measured using the three-point bending test. Color changes (ΔE) were determined spectrophotometrically. Results: The disinfection agents showed no significant influence on the E-modulus compared to distilled water (Acrylic vs. distilled water from (Futura Gen) 2688.80 ± 230.78 vs. 2766.60 ± 91.22 MPa to (PalaXpress) 3004.20 ± 26.40 vs. 2851.00 ± 95.23 MPa). Flexural strength after storage in distilled water and disinfection did not differ significantly (Acrylic vs. distilled water from (Paladon65) 27.28 ± 1.30 vs. 28.42 ± 0.84 N/mm2, (p > 0.05) to (PalaXpress) 30.88 ± 0.25 vs. 29.68 ± 0.79 N/mm2, p < 0.001). Disinfection caused a significant color change with Impresept of Paladon 65 (p ≤ 0.001), FuturaAcryl 2000 with Stammopur DR and D 050 Instru-Gen (p ≤ 0.001). Conclusions: The investigated disinfection agents did not influence elastic modulus and flexural strength of denture base resins negatively. ΔE-values were in a range of 1 to 2. Thus, the detected color changes may be marginal. Clinical relevance: Single use disinfections are feasible for acrylic dentures regarding to elastic modulus and flexural strength.
基金supported by the Lithuanian Ministry of Agriculture.
文摘The aim of the study was to determine the impact of residues of detergents and disinfectants on the results of most commonly used inhibitor tests for raw milk. Microbiological test (Delvotest SP-NT) and three rapid tests (Charm 3 MRL BL/TET2, Charm ROSA MRL BL/TET and Penzym) were used in the study. Three concentrations (recommended by the manufacturer, 10 times lower and twice higher) of 36 detergents and disinfectants in raw milk were investigated. All methods did not detect concentrations of detergents and disinfectants of alkaline and acid origin 10 times lower than recommended by the manufacturer. 39% of the investigated substances of alkaline origin were detected by Delvotest SP-NT and Penzym;Charm tests showed non-typical results only. Delvotest SP-NT did not detect substances of acid origin;Penzym detected 50% of these substances, Charm tests showed only non-typical results. Delvotest SP-NT and Penzym appeared to be more sensitive to the substances used for teat hygiene and disinfection. The scope of rapid tests (receptor or enzymatic) does not cover the detection of detergent and disinfectant re- sidues in milk. However, according to the non-typical results of the test, it is possible to suspect the presence of these substances in milk. McNemar’s and Cochran’s Q tests were used for statistical analysis of the data.
基金This research was supported by the Extracurricular Scientific Research Program for Students of Sun Yat-Sen University
文摘Aim: This study aims to assess the infection risks of flashlight contamination in a stomatology hospital and compare the disinfection effectiveness of alcohol (75%) and disinfecting wipes.Background: The flashlight is a basic non-critical medical device in oral and maxillofacial surgery wards. Wounds are mostly found in oral cavities;therefore, reusable flashlights may be a potential source of nosocomial infections (NIs). However, the microbial flora present in flashlights used in hospitals has not yet been explored. Methods: This study investigated the microbial contamination of 41 flashlights used in a stomatology hospital in Guangzhou in March 2016. Results: Results indicated that 75.6%(31/41) of the flashlights had microbial contamination. Gram-positive bacteria accounted for 72.7%(24/33)of the microbial groups contaminating the flashlights, and Gram-negative bacteria (21.2%, 7/33), and fungi (6.1%, 2/33) constituted the remaining contaminants. The predominantly isolated species was Staphyloccus (66.7%, 22/33), especially Staphylococcus aureus (24.2%, 8/33). Approximately 77.3%(17/22) of the types of bacteria detected in the hands were same as those in the corresponding flashlights. Both the bacterial overstandard and S. aureus detection rates of doctors' flashlights were higher than those of nurses' flashlights (16/17 vs. 14/23, 7/17 vs. 1/23, respectively) (P < 0.05). Moreover, both disinfectants performed excellently, and their eligibility rates were not significantly different (17/17 vs. 14/14) (P>0.05). Conclusion: Flashlights are potential causes of NIs. Disinfecting flashlights could be an effective and practical infection control method.
基金Supported by the National Natural Science Foundation of China,No.81873116。
文摘BACKGROUND Misuse of disinfectants during the coronavirus disease 2019 pandemic has led to several poisoning incidents.However,there are few clinical case reports on poisoning caused by improper mixing of household disinfectants.AIM To summarize the clinical characteristics and treatment effects of chlorine poisoning caused by improper mixing of hypochlorite bleach with acidic cleaning agents.METHODS We retrospectively analyzed baseline and clinical data,clinical symptoms,and treatment methods of seven patients with chlorine poisoning who were admitted to the National Army Poisoning Treatment Center.RESULTS Among the seven patients,the average poisoning time(exposure to admission)was 57 h(4-240 h).All patients were involved in cleaning bathrooms.Chest computed tomography scans revealed bilateral lung effusions or inflammatory changes in five patients.The partial pressure of oxygen decreased in six patients,and respiratory failure occurred in one.Five patients had different degrees of increase in white blood cell count.Humidified oxygen therapy,non-invasive mechanical ventilation,anti-inflammatory corticosteroids,antioxidants,and antibiotics were administered for treatment.The average length of hospital stay was 7 d(4-9 d).All seven patients recovered and were discharged.CONCLUSION Improper mixing of household disinfectants may cause damage to the respiratory system due to chlorine poisoning.Corticosteroids may improve lung exudation in severe cases,and symptomatic supportive treatment should be performed early.
基金Funded by the Xuhui District Medical Research Project(No.SHXH201913)the Clinical Research on Health Industry of Shanghai Municipal Health Commission(No.202040085)+1 种基金the Shanghai Medical Key Specialty(No.ZK2019B12)the National Natural Science Foundation of China(No.32000945)。
文摘To investigate the corrosion behaviors and antibacterial effects of sodium hypochlorite(NaClO)and hydrogen peroxide silver ion(HPSI)disinfectants with different concentrations against dental unit waterlines and provide guidance and reference for the use of chemical disinfectants,polyurethane tubes were immersed in ultrapure water(control group),0.1%NaClO,0.5%NaClO,1.0%NaClO,2.5%HPSI,5.0%HPSI,and 10%HPSI solutions for 6,12,and 18 weeks.Contact angles and Fourier transform infrared spectra were detected.Surface morphologies were observed using scanning electron microscopy and antibacterial activity was evaluated using Gram-positive Staphylococcus aureus(S.aureus).The results showed that sodium hypochlorite and hydrogen peroxide silver ion disinfectants presented good antibacterial activity against S.aureus.However,sodium hypochlorite could cause serious damage to the water pipes where corrosion pits and cracks were observed,and increasing the concentration of sodium hypochlorite could accelerate the corrosion process.Hydrogen peroxide silver ion disinfectants had no obvious damage to the water pipes.Therefore,hydrogen peroxide silver ion disinfectants are recommended to use for controlling bacterial infection in dental unit waterlines which can reduce the damage to the water pipes.
基金supported by the National Key R&D Program of China(2018YFC1200600)the grant from the State Key Laboratory of Veterinary Biotechnology Program(SKLVBP201801)the National Science and Technology Major Project of China(2018ZX10734401-018-002)。
文摘Prevention of African swine fever,a disease caused by African swine fever virus(ASFV),requires maintenance of high biosecurity standards,which principally relies on disinfection.Finding the perfect disinfectant against ASFV is difficult because of the lack of relevant data.Therefore,we aimed to find the most effective disinfectant and to optimise its concentration as well as contact time to confirm the viricidal effect against ASFV in vitro.We evaluated the viricidal activity of three concentrations each of six common disinfectants against ASFV using immersion disinfection assay(IDA)and spray disinfection assay(SDA);the concentrations of these disinfectants at which complete viral inactivation occurred were almost same as the manufacturer-recommended concentrations,but the exposure times for viral inactivation are different.The following disinfectants(assay:concentration,exposure time)showed complete inactivation:iodine and acid mixed solution(IDA/SDA:0.5%,10 min);compound potassium peroxymonosulfate(IDA:0.25%,30 min;SDA:0.25%,60 min);citric acid(IDA:0.25%,60 min;SDA:0.5%,60 min);sodium dichloroisocyanurate(IDA:0.125%,60 min;SDA:0.25%,60 min);and glutaral ang deciquam(IDA/SDA:0.2%,60 min);and deciquam(IDA/SDA:0.5%,60 min).However,in the presence of organic material contamination,disinfectants did not show a marked inactivation effect.Therefore,disinfection procedures should be performed in two steps:thorough mechanical cleaning followed by application of disinfectant.In conclusion,all the tested disinfectants can inactivate ASFV;these can be used as alternative disinfectants to enhance biosecurity.
基金Sponsored by the Foundation of the Key Science and Technology Projections of Harbin (Grant No. 2003AA4CS183).
文摘The disinfection effect of chlorine dioxide, chlorine and their mixture on heterotrophic bacteria, iron bacteria and sulfate-reducing bacteria in circulating cooling water was studied. The results of the test indicated that high purity chlorine dioxide was the most effective biocide in the 3 disinfectants, and with a dosage of 0.5 mg/L, chlorine dioxide could obtain perfect effect. High purity chloride dioxide could have the excellent effect with the pH value of 6 to 10, and could keep it within 72 h. Chlorine and their mixture couldn’t reach the effect of chlorine dioxide.
基金supported by funds from the National Key R&D Program of China (2022YFE0203100)the CAMS Innovation Fund for Medical Sciences (CIFMS 2021-I2M-1-038 and CIFMS 2022-I2M-1-021)the National Natural Science Foundation of China (82271802,82241075,and 82072288).
文摘Monkeypox(mpox)outbreak in 2022 has caused more than 91,000 cases,has spread to 115 countries,regions,and territories,and has thus attracted much attention.The stability of poxvirus particles in the environment is recognized as an important factor in determining their transmission.However,few studies have investigated the persistence of poxviruses on material surfaces under various environmental conditions,and their sensitivity to biocides.Here,we systematically measured the stability of vaccinia virus(VACV)under different environmental conditions and sensitivity to inactivation methods via plaque assay,quantitative real‐time polymerase chain reaction(qPCR),and Gaussia luciferase(G‐luciferase)reporter system.The results show that VACV is stable on the surface of stainless steel,glass,clothing,plastic,towel,A4 paper,and tissue and persists much longer at 4℃ and?20℃,but is effectively inactivated by ultraviolet(UV)irradiation,heat treatment,and chemical reagents.Our study raises the awareness of long persistence of poxviruses in the environment and provides a simple solution to inactivate poxviruses using common disinfectants,which is expected to help the control and prevention of mpox virus and future poxvirus outbreaks.
文摘In clinical practice,the important hygienic prevention of bacterial pathogen spread is disinfection of potentially contaminated area.Benzalkonium bromide and chlorhexidine acetate are commonly used disinfectants with a broad spectrum of antimicrobial effect.It is vital to inhibit the spread of pathogen in hospital.However,a large number of pathogens with the decreased antiseptic susceptibility have been isolated from clinical samples which showed an increased minimal inhibitory concentration(MIC)against those antiseptics.These resistant pathogens are the major causes for nosocomial crossinfections in hospital.The present study demonstrated the utility of Oxford plate assay system in determining the potential disinfectant resistance of bacteria.The microbiological assay is based on the inhibitory effect of tested disinfectants upon the strains of Staphylococcus aureus and Escherichia coli.Statistical analysis of the bioassay results indicated the linear correlation(r=-0.87-0.99,P<0.01)between the diameter of growth inhibition zone and the log dosage of the tested disinfectants.Moreover,comparison of inhibitory efficacy of benzalkonium bromide upon 29 S.aureus strains isolated from clinical samples by both Oxford plate method and broth dilution method showed that the diameter of growth inhibition zone has significantly negative correlation with the minimal inhibitory concentration(MIC)(r=-0.574,P<0.001).These results suggest that the Oxford plate is a simple and time-saving method in detecting potential clinical disinfectant resistance and its usefulness for routine surveillance of pathogenic resistance to disinfectants warrants further investigation.
文摘Concerns about air quality in dental clinics where aerosol generation during procedures poses significant health risks,have prompted investigations on advanced disinfection technologies.This editorial describes the strengths and limitations of ventilation and aerosol control measures in dental offices,especially with respect to the use of graphene nanocomposites.The potential of graphene nanocomposites as an innovative solution to aerosol-associated health risks is examined in this review due to the unique properties of graphene(e.g.,high con-ductivity,mechanical strength,and antimicrobial activity).These properties have produced promising results in various fields,but the application of graphene in dentistry remains unexplored.The recent study by Ju et al which was published in World Journal of Clinical Cases evaluated the effectiveness of graphene-based air disinfection systems in dental clinics.The study demonstrated that graphene-based disinfection techniques produced significant reductions in suspended particulate matter and bacterial colony counts,when co-mpared with traditional methods.Despite these positive results,challenges such as material saturation,frequency of filter replacement,and associated costs must be addressed before widespread adoption of graphene-based disinfection techniques in clinical practice.Therefore,there is need for further research on material structure optimization,long-term safety evaluations,and broader clinical applications,in order to maximize their positive impact on public health.
文摘This manuscript features the promising findings of a study conducted by Ju et al,who used graphene nanocomposites for air disinfection in dental clinics.Their study demonstrated that,compared with conventional filters,graphene nanocom-posites substantially improved air quality and reduced microbial contamination.This manuscript highlights the innovative application of graphene materials,emphasizing their potential to enhance dental clinic environments by minimizing secondary pollution.On the basis of the unique antimicrobial properties of gra-phene and the original study’s rigorous methodology,we recommend using gra-phene nanocomposites in clinical settings to control airborne infections.
基金supported by the National Natural Science Foundation of China(52325001,52170009,and 52091542)the National Key Research and Development Program of China(2021YFC3200700)+3 种基金the Program of Shanghai Academic Research Leader,China(21XD1424000)the International Cooperation Project of Shanghai Science and Technology Commission(20230714100)the Key-Area Research and Development Program of Guangdong Province(2020B1111350001)Tongji University Youth 100 Program.
文摘Tracing the contamination origins in water sources and identifying the impacts of natural and human processes are essential for ecological safety and public health.However,current analysis approaches are not ideal,as they tend to be laborious,time-consuming,or technically difficult.Disinfection byproducts(DBPs)are a family of well-known secondary pollutants formed by the reactions of chemical disinfectants with DBP precursors during water disinfection treatment.Since DBP precursors have various origins(e.g.,natural,domestic,industrial,and agricultural sources),and since the formation of DBPs from different precursors in the presence of specific disinfectants is distinctive,we argue that DBPs and DBP precursors can serve as alternative indicators to assess the contamination in water sources and identify pollution origins.After providing a retrospective of the origins of DBPs and DBP precursors,as well as the specific formation patterns of DBPs from different precursors,this article presents an overview of the impacts of various natural and anthropogenic factors on DBPs and DBP precursors in drinking water sources.In practice,the DBPs(i.e.,their concentration and speciation)originally present in source water and the DBP precursors determined using DBP formation potential tests—in which water samples are dosed with a stoichiometric excess of specific disinfectants in order to maximize DBP formation under certain reaction conditions—can be considered as alternative metrics.When jointly used with other water quality parameters(e.g.,dissolved organic carbon,dissolved organic nitrogen,fluorescence,and molecular weight distribution)and specific contaminants of emerging concern(e.g.,certain pharmaceuticals and personal care products),DBPs and DBP precursors in drinking water sources can provide a more comprehensive picture of water pollution for better managing water resources and ensuring human health.
基金The Natural Science Research Project of Minhang District,No.2021MHZ070.
文摘BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in dental clinics by leveraging its adsorption and antibacterial properties.METHODS Patients who received ultrasonic cleaning at our hospital from April 2023 to April 2024.They were randomly assigned to three groups(n=20 each):Graphene nanocomposite material suction group(Group A),ordinary filter suction group(Group B),and no air suction device group(Group C).The air quality and air colony count in the clinic rooms were assessed before,during,and after the procedure.Additionally,bacterial colony counts were obtained from the air outlets of the suction devices and the filter screens in Groups A and B.RESULTS Before ultrasonic cleaning,no significant differences in air quality PM2.5 and colony counts were observed among the three groups.However,significant differences in air quality PM2.5 and colony counts were noted among the three groups during ultrasonic cleaning and after ultrasonic treatment.Additionally,the number of colonies on the exhaust port of the suction device and the surface of the filter were significantly lower in Group A than in Group B(P=0.000 and P=0.000,respectively).CONCLUSION Graphene nanocomposites can effectively sterilize the air in dental clinics by exerting their antimicrobial effects and may be used to reduce secondary pollution.
基金supported by the America University,the Swiss Agency for Development and Cooperation,and the Central Technical Institute.
文摘Sodium hypochlorite has significant potential as a sanitation solution in hard-to-reach areas.Few studies have investigated the optimal electrolysis parameters for its production with volumes greater than 1o L.This study evaluated sodium hypochlorite production through electrolysis in a 22-L prototype and identified the optimal operating parameters.Tests were performed using graphite electrodes with areas of 68.4 cm^(2) at the laboratory scale and 1865.0 cm^(2) at the prototype scale.A design for experiments with different operating times,chloride concentrations,and electric current intensities was developed.The optimal operating time,sodium chloride concentration,and current intensity at the laboratory scale were 120 min,150 g of chloride per liter,and 3 A,respectively,leading to the production of 5.02 g/L of the disinfectant with an energy efficiency of 12.21 mg of Cl_(2) per kilojoule.At the prototype scale,the maximum sodium hypochlorite concentration of 3.99 g of chloride per liter was achieved with an operating time of 120 min,a sodium chloride concentration of 100 g of chloride per liter,and a current intensity of 70 A,reaching an energy efficiency of 42.56 mg of Cl_(2) per kilojoule.In addition,this study evaluated the influences of the chloride concentration,current intensity,and operating time on the production of sodium hypochlorite at the two scales,and formulated the equations showing the trends of sodium hypochlorite production and energy efficiency in the electrochemical systems.The 22-L prototype model for production of this oxidizing substance is promising for disinfection of large volumes of water in areas that are difficult to access.
基金West China Nursing Discipline Development Special Fund Project,No.HXHL21029。
文摘BACKGROUND Commonly used cleaning brushes in the reprocessing of flexible endoscopes often cause damage within the working channels.AIM To develop a spray flushing system to achieving effective cleaning of the working channels while minimizing damage.METHODS This prospective study included 60 used endoscopes and 60 Teflon tubes randomly divided into a control group(n=30)and an experimental group(n=30).The material of Teflon tubes was the same as that of the endoscope working channel.Endoscopes in the control group were manually cleaned using traditional cleaning brushes,while those in the experimental group were cleaned using the newly developed spray flushing system.ATP levels,cleanliness,and microbiological testing of the working channels were measured.Additionally,Teflon tubes in the control group underwent 500 passes with a cleaning brush,while those in the experimental group were subjected to the spray flushing system,and channel damage was evaluated.RESULTS The ATP levels(RLU)in the two groups were 32.5(13-66)and 26(16-40),respectively(P>0.05).Cleanliness scores were 1.5(1-2)and 1(1-2),respectively(P>0.05).Debris was found in 73.3%of the control group,which was significantly higher than 46.7%in the experimental group(P<0.05).Microbiological tests for both groups yielded negative results.Teflon tube damage in the control group was rated at 4(4-5.25),which was significantly higher than in the experimental group 4(3-4)(P<0.01).CONCLUSION The spray flushing system demonstrated superior efficacy in removing debris and resulted in less damage to the endoscope working channels compared with traditional cleaning brushes.
基金funded by the Foundation of State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants(Grant No.SEPKL-EHIAEC-202210)the Foundation of Shanghai Municipal Health Commission(Grant No.202240327)the Key Discipline Project of the Three-year Action Plan for Strengthening Public Health System Construction in Shanghai(2023-2025)(Grant No.GWVI-11.1-38)。
文摘Objective Chlorination is often used to disinfect recreational water in large amusement parks;however,the health hazards of chlorination disinfection by-products(DBPs)to occupational populations are unknown.This study aimed to assess the exposure status of chlorinated DBPs in recreational water and the health risks to employees of large amusement parks.Methods Exposure parameters of employees of three large amusement parks in Shanghai were investigated using a questionnaire.Seven typical chlorinated DBPs in recreational water and spray samples were quantified by gas chromatography,and the health risks to amusement park employees exposed to chlorinated DBPs were evaluated according to the WHO's risk assessment framework.Results Trichloroacetic acid,dibromochloromethane,bromodichloromethane,and dichloroacetic acid were detected predominantly in recreational water.The carcinogenic and non-carcinogenic risks of the five DBPs did not exceed the risk thresholds.In addition,the carcinogenic and non-carcinogenic risks of mixed exposure to DBPs were within the acceptable risk limits.Conclusion Typical DBPs were widely detected in recreational water collected from three large amusement parks in Shanghai;however,the health risks of DBPs and their mixtures were within acceptable limits.
文摘Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization supply center from January 2021 to January 2023.The work situation before January 31,2022,was classified as the control group;a routine quality control management model was implemented,and the work situation after January 31,2022,was classified as the observation group.The quality of medical device management and department satisfaction between the two groups were compared.Results:The timely recovery and supply rate,classification and cleaning pass rate,disinfection pass rate,packaging pass rate,sterilization pass rate,and department satisfaction score in the observation group were all higher than those of the control group(P<0.05).Conclusion:Implementing a refined quality control management model in the sterilization supply center can improve the quality management level of medical devices and department satisfaction and is worthy of promotion.
基金supported by National Natural Science Foundation of China(52208272,41706080 and 51702328)the Basic Scientific Fund for National Public Research Institutes of China(2020S02 and 2019Y03)+3 种基金the Basic Frontier Science Research Program of Chinese Academy of Sciences(ZDBS-LY-DQC025)the Young Elite Scientists Sponsorship Program by CAST(No.YESS20210201)the Strategic Leading Science&Technology Program of the Chinese Academy of Sciences(XDA13040403)the Key Research and Development Program of Shandong Province(Major Scientific and Technological Innovation Project)(2019JZZY020711).
文摘Since the catalytic activity of most nanozymes is still far lower than the corresponding natural enzymes,there is urgent need to discover novel highly efficient enzyme-like materials.In this work,Co_(3)V_(2)O_(8)with hollow hexagonal prismatic pencil structures were prepared as novel artificial enzyme mimics.They were then decorated by photo-depositing Ag nanoparticles(Ag NPs)on the surface to further improve its catalytic activities.The Ag NPs decorated Co_(3)V_(2)O_(8)(ACVPs)showed both excellent oxidase-and peroxidase-like catalytic activities.They can oxidize the colorless 3,3’,5,5’-tetramethylbenzidine rapidly to induce a blue change.The enhanced enzyme mimetic activities can be attributed to the surface plasma resonance(SPR)effect of Ag NPs as well as the synergistic catalytic effect between Ag NPs and Co_(3)V_(2)O_(8),accelerating electron transfer and promoting the catalytic process.ACVPs were applied in constructing a colorimetric sensor,validating the occurrence of the Fenton reaction,and disinfection,presenting favorable catalytic performance.The enzyme-like catalytic mechanism was studied,indicating the chief role of⋅O_(2)-radicals in the catalytic process.This work not only discovers a novel functional material with double enzyme mimetic activity but also provides a new insight into exploiting artificial enzyme mimics with highly efficient catalytic ability.