BACKGROUND This case of gestational gingival tumor is huge and extremely rare in clinical practice.As the growth location of this gingival tumor is in the upper anterior tooth area,it seriously affects the pregnant wo...BACKGROUND This case of gestational gingival tumor is huge and extremely rare in clinical practice.As the growth location of this gingival tumor is in the upper anterior tooth area,it seriously affects the pregnant woman's speech and food,causing great pain to the patient.The use of Nd:YGA water mist laser to remove the gingival tumor resulted in minimal intraoperative bleeding,minimal adverse reactions,and good postoperative healing,which is worthy of clinical promotion and application.CASE SUMMARY The patient,a pregnant woman,reported a large lump in her mouth on the first day of postpartum treatment.Based on medical history and clinical examination,the diagnosis was diagnosed as gestational gingival tumor.Postoperative pathological biopsy also confirmed this diagnosis.The use of Nd:YAG water mist laser to remove the tumor resulted in minimal intraoperative bleeding,clear surgical field of view,short surgical time,and good postoperative healing.CONCLUSION In comparison to traditional surgery,Nd:YAG water mist laser surgery is minimally invasive,minimizes cell damage,reduces bleeding,ensures a clear field of vision,and virtually eliminates postoperative edema,carbonization,and the risk of cross infection.It has unique advantages in oral soft tissue surgery for pregnant patients.Therefore,the clinical application of Nd:YAG water mist laser for the treatment of gestational gingival tumors is an ideal choice.展开更多
Introduction: Ureteroscopy is a minimally invasive endoscopic surgery which provides access to the ureter, pyelon and calyceal cavities via the urethra and the bladder. Laser ureteroscopy uses the laser as an energy s...Introduction: Ureteroscopy is a minimally invasive endoscopic surgery which provides access to the ureter, pyelon and calyceal cavities via the urethra and the bladder. Laser ureteroscopy uses the laser as an energy source to treat the stone and eliminate it naturally. Minimally invasive endoscopic methods are struggling to become popular in sub-Saharan African countries, especially for the upper urinary tract. The objective of our work was to report the results of our first laser ureteroscopy experience in the department. Materials and Methods: This was a prospective and descriptive study running from December 1, 2023 to February 19, 2024. Included in our study was any case of upper urinary tract stone operated by Laser ureteroscopy. The characteristics of the lithiasis were determined by CT scan. Sterilization of urine was verified by carrying out a cytobacteriological examination of urine. Ureteral lithiasis was approached by semi-rigid ureteroscopy. Renal lithiasis was immediately addressed by flexible ureteroscopy. Ureteroscopy was coupled with a Holmium YAG laser. A double J ureteral catheter was placed after the operation. A 230 µm laser fiber was used in each case with a generator with a power of 35 watts (Storz Calculase III type). An access sheath was used in all cases of flexible ureteroscopy. The parameters studied were: sociodemographic characteristics, lithiasis (site, size, number, density, topography), type of anesthesia, duration of laser use, duration of intervention, postoperative outcomes. Data entry and analysis were carried out using the software (Word 2016 and SPSS). Result: We collected 30 cases of laser ureteroscopy. The average age was 37 years with extremes of 9 and 79 years. The male gender was more represented. The most common age group was 24-39 years old. Renal colic was the most frequent reason for admission, 12 patients (40%). On physical examination, lumbar tenderness was present in 47% (14 patients). ECBU was positive in 4 patients (13%). CT scan was performed in all our patients before the intervention. The average stone size was 12 mm and the largest was 23 mm. The majority of stones, i.e. 59% (18 patients), had a density greater than 1000 HU. The stone was unique in 19 patients (63%). The location of the stone was pyelic in 8 patients or 27%. An impact on the upper urinary tract was found in 16 of our patients or 53%. General anesthesia was used in 25 patients (83%). A digital flexible ureteroscopy was used in 24 patients and a semi-rigid ureteroscopy (URS) in 6 patients. Full-course fragmentation was the most used therapeutic method, 9 patients or 32%. The average duration of interventions was 61 minutes. Drainage by double J catheter at the end of the procedure was performed in all our patients. The length of hospitalization was 24 hours. Only one case of failure in the USSR was recorded, and one case of failure was in the semi-rigid URS. Conclusion: Laser ureteroscopy is an effective minimally invasive surgery in the management of lithiasis of the upper urinary tract. It significantly reduces the length of hospitalization. Mastery of this technique and the acquisition of the equipment necessary for its implementation is an undeniable asset in the management of renal and ureteral lithiasis.展开更多
目的:比较使用不同模式Er:YAG激光以及传统车针去龋后牙本质与复合树脂的粘接强度。方法:选用人类离体磨牙模拟龋坏,分别采用Er:YAG激光中短脉冲(medium short pulse,MSP)模式、Er:YAG激光超短脉冲(super short pulse,SSP)模式和传统车...目的:比较使用不同模式Er:YAG激光以及传统车针去龋后牙本质与复合树脂的粘接强度。方法:选用人类离体磨牙模拟龋坏,分别采用Er:YAG激光中短脉冲(medium short pulse,MSP)模式、Er:YAG激光超短脉冲(super short pulse,SSP)模式和传统车针去除模拟的龋坏后,采用自酸蚀粘接剂将牙体标本与复合树脂粘接制成试件。使用万能试验机对试件进行拉伸试验,测得断裂负荷和粘接强度,并采用单因素方差分析和Tukey多重比较进行统计学分析。采用扫描电子显微镜观察3种不同去龋方式处理后的牙本质表面形态,以及涂布自酸蚀粘接剂并固化后试件的横截面形态。结果:使用Er:YAG激光MSP模式处理后牙本质与复合树脂的粘接强度最高,SSP模式处理后次之,传统车针处理后最低,但差异无统计学意义(P>0.05)。扫描电子显微镜图像显示,Er:YAG激光MSP模式处理后的牙本质表面较平坦,牙本质小管内几乎没有残屑;Er:YAG激光SSP模式处理后的牙本质表面呈现鳞片状,牙本质小管内可见少量碎屑;而传统车针处理后牙本质小管大部分处于被表面牙本质部分甚至完全遮盖的状态,牙本质小管内充满残屑。结论:使用Er:YAG激光去龋相比传统车针去龋可以获得较好的牙本质粘接强度,且对牙本质小管的处理深度和洁净度明显优于传统车针去龋,其中MSP模式更佳。展开更多
A laser-diode-pumped Nd: YAG laser Q-switched Passively with a YAG colorcenter chip has been deveolped. The Q-switched pulse output has a duration of 25-70ns,an energy of about 7.9 μJ and a repetition frequency of 1....A laser-diode-pumped Nd: YAG laser Q-switched Passively with a YAG colorcenter chip has been deveolped. The Q-switched pulse output has a duration of 25-70ns,an energy of about 7.9 μJ and a repetition frequency of 1.25-5.0kHz when the laser cavityparameters and pump power are changed. The Q-switched dynamics is analyzed with therate equation theorry. The theoretical and experimental results agree well.展开更多
YAG laser welding with surface activating flux has been investigated, and the influencing factors and mechanism are discussed. The results show that both surface activating flux and surface active element S have fanta...YAG laser welding with surface activating flux has been investigated, and the influencing factors and mechanism are discussed. The results show that both surface activating flux and surface active element S have fantastic effects on the YAG laser weld shape, that is to obviously increase the weld penetration and D/W ratio in various welding conditions. The mechanism is thought to be the change of weld pool surface tension temperature coefficient, thus, the change of fluid flow pattern in weld pool due to the flux.展开更多
This study compared the efficacy of 70- and 120-w 2-μm thulium:YAG VapoEnucleation of the prostate (ThuVEP) for patients with benign prostatic obstruction (BPO). A prospective analysis of 84 patients with sympto...This study compared the efficacy of 70- and 120-w 2-μm thulium:YAG VapoEnucleation of the prostate (ThuVEP) for patients with benign prostatic obstruction (BPO). A prospective analysis of 84 patients with symptomatic BPO and prostatic enlargement (t〉 60 ml) who underwent either 70-w (n=44) or 120-w ThuVEP (n=40) non-randomly was carried out. Patient demographics and perioperative and 12-month follow-up data were analysed. The mean prostate volume was 79.90---27.49 ml in patients who had received 70-w ThuVEP, which was less than in those who had received 120-w ThuVEP (88.53+-25.10; P=0.033). The mean enucleation (resected weight/laser time, 2.16±1.21 g min-1 vs. 1.23±0.60 g min-1; P=-0.013), operation efficiency (resected weight/total operation time, 0.76±0.35 g min-1 vs. 0.42+-0.27 g min-1; P=-0.000) and percentage of resected tissue (66.93%±22.79% vs. 45.41%±23.33%; P=-0.000) were higher with 120-w treatment compared to 70-w ThuVEP. One patient (1.2% of total patients) (in the 120-w group) required a blood transfusion postoperatively. Sixty-one patients (73%) were available for review at the 12-month follow-up time point. The quality of life (QoL), International Prostate Symptom Score (IPSS), maximum urinary flow rate (Qmax), postvoiding residual urine (PVR) and prostate volume improved significantly after treatment (P≤ 0.035) and were not significantly different between those treated with the different devices (70- and 120-w). The median prostate volume reduction was 81.70% and 82.19% with 70- and 120-w ThuVEP, respectively. The incidence of complications was low and did not differ between groups treated with the different devices. Two patients (2.4%) (one per group) had a bladder neck contracture at the follow-up. ThuVEP is a safe and efficacious procedure for the treatment of symptomatic BPO. The incidence of complications was low with both devices. The 120-w thulium:YAG device enhances the effectiveness of Th,VEP with reeard to the oercentaee of resected tissue and the enucleation/ooeration efficiency.展开更多
AIM:To investigate the effects of a new opening pattern in neodymium:yttrium-aluminum-garnet(Nd:YAG)laser posterior capsulotomy on visual function.METHODS:This technique was conducted along a circular pattern.The ener...AIM:To investigate the effects of a new opening pattern in neodymium:yttrium-aluminum-garnet(Nd:YAG)laser posterior capsulotomy on visual function.METHODS:This technique was conducted along a circular pattern.The energy ranged between 0.8 and1.2 mJ/pulse was consumed and mean total energy levels were 74±21 mJ(mean±standard deviation:SD,from 40 to167)and laser shots aimed at 150μm away behind a datum point and went along an imaginary line which extends 0.5 mm inside from optic margin and into the circular en bloc pattern.Vitreous stands were attached with fragment and then they were cut off by the laser after circular application.The circular fragment was completely separated from vitreous,and then this fragment was quickly sunk in intravitreal space.RESULTS:The follow-up period ranges from at least a week to 40mo,making 15.8mo on average.The procedural outcome showed 96%(74 eyes out of the 77eyes)enhancement in patients’visual acuity.Cystoid macular edema or retinal detachment was not observed in any of the patients during follow-up periods.CONCLUSION:This new technique is expected to improve the weaknesses that the conventional procedures have by adding the process to cut off vitreous stands attached with the fragment by the laser to the circular application.展开更多
文摘BACKGROUND This case of gestational gingival tumor is huge and extremely rare in clinical practice.As the growth location of this gingival tumor is in the upper anterior tooth area,it seriously affects the pregnant woman's speech and food,causing great pain to the patient.The use of Nd:YGA water mist laser to remove the gingival tumor resulted in minimal intraoperative bleeding,minimal adverse reactions,and good postoperative healing,which is worthy of clinical promotion and application.CASE SUMMARY The patient,a pregnant woman,reported a large lump in her mouth on the first day of postpartum treatment.Based on medical history and clinical examination,the diagnosis was diagnosed as gestational gingival tumor.Postoperative pathological biopsy also confirmed this diagnosis.The use of Nd:YAG water mist laser to remove the tumor resulted in minimal intraoperative bleeding,clear surgical field of view,short surgical time,and good postoperative healing.CONCLUSION In comparison to traditional surgery,Nd:YAG water mist laser surgery is minimally invasive,minimizes cell damage,reduces bleeding,ensures a clear field of vision,and virtually eliminates postoperative edema,carbonization,and the risk of cross infection.It has unique advantages in oral soft tissue surgery for pregnant patients.Therefore,the clinical application of Nd:YAG water mist laser for the treatment of gestational gingival tumors is an ideal choice.
文摘Introduction: Ureteroscopy is a minimally invasive endoscopic surgery which provides access to the ureter, pyelon and calyceal cavities via the urethra and the bladder. Laser ureteroscopy uses the laser as an energy source to treat the stone and eliminate it naturally. Minimally invasive endoscopic methods are struggling to become popular in sub-Saharan African countries, especially for the upper urinary tract. The objective of our work was to report the results of our first laser ureteroscopy experience in the department. Materials and Methods: This was a prospective and descriptive study running from December 1, 2023 to February 19, 2024. Included in our study was any case of upper urinary tract stone operated by Laser ureteroscopy. The characteristics of the lithiasis were determined by CT scan. Sterilization of urine was verified by carrying out a cytobacteriological examination of urine. Ureteral lithiasis was approached by semi-rigid ureteroscopy. Renal lithiasis was immediately addressed by flexible ureteroscopy. Ureteroscopy was coupled with a Holmium YAG laser. A double J ureteral catheter was placed after the operation. A 230 µm laser fiber was used in each case with a generator with a power of 35 watts (Storz Calculase III type). An access sheath was used in all cases of flexible ureteroscopy. The parameters studied were: sociodemographic characteristics, lithiasis (site, size, number, density, topography), type of anesthesia, duration of laser use, duration of intervention, postoperative outcomes. Data entry and analysis were carried out using the software (Word 2016 and SPSS). Result: We collected 30 cases of laser ureteroscopy. The average age was 37 years with extremes of 9 and 79 years. The male gender was more represented. The most common age group was 24-39 years old. Renal colic was the most frequent reason for admission, 12 patients (40%). On physical examination, lumbar tenderness was present in 47% (14 patients). ECBU was positive in 4 patients (13%). CT scan was performed in all our patients before the intervention. The average stone size was 12 mm and the largest was 23 mm. The majority of stones, i.e. 59% (18 patients), had a density greater than 1000 HU. The stone was unique in 19 patients (63%). The location of the stone was pyelic in 8 patients or 27%. An impact on the upper urinary tract was found in 16 of our patients or 53%. General anesthesia was used in 25 patients (83%). A digital flexible ureteroscopy was used in 24 patients and a semi-rigid ureteroscopy (URS) in 6 patients. Full-course fragmentation was the most used therapeutic method, 9 patients or 32%. The average duration of interventions was 61 minutes. Drainage by double J catheter at the end of the procedure was performed in all our patients. The length of hospitalization was 24 hours. Only one case of failure in the USSR was recorded, and one case of failure was in the semi-rigid URS. Conclusion: Laser ureteroscopy is an effective minimally invasive surgery in the management of lithiasis of the upper urinary tract. It significantly reduces the length of hospitalization. Mastery of this technique and the acquisition of the equipment necessary for its implementation is an undeniable asset in the management of renal and ureteral lithiasis.
文摘目的:比较使用不同模式Er:YAG激光以及传统车针去龋后牙本质与复合树脂的粘接强度。方法:选用人类离体磨牙模拟龋坏,分别采用Er:YAG激光中短脉冲(medium short pulse,MSP)模式、Er:YAG激光超短脉冲(super short pulse,SSP)模式和传统车针去除模拟的龋坏后,采用自酸蚀粘接剂将牙体标本与复合树脂粘接制成试件。使用万能试验机对试件进行拉伸试验,测得断裂负荷和粘接强度,并采用单因素方差分析和Tukey多重比较进行统计学分析。采用扫描电子显微镜观察3种不同去龋方式处理后的牙本质表面形态,以及涂布自酸蚀粘接剂并固化后试件的横截面形态。结果:使用Er:YAG激光MSP模式处理后牙本质与复合树脂的粘接强度最高,SSP模式处理后次之,传统车针处理后最低,但差异无统计学意义(P>0.05)。扫描电子显微镜图像显示,Er:YAG激光MSP模式处理后的牙本质表面较平坦,牙本质小管内几乎没有残屑;Er:YAG激光SSP模式处理后的牙本质表面呈现鳞片状,牙本质小管内可见少量碎屑;而传统车针处理后牙本质小管大部分处于被表面牙本质部分甚至完全遮盖的状态,牙本质小管内充满残屑。结论:使用Er:YAG激光去龋相比传统车针去龋可以获得较好的牙本质粘接强度,且对牙本质小管的处理深度和洁净度明显优于传统车针去龋,其中MSP模式更佳。
文摘A laser-diode-pumped Nd: YAG laser Q-switched Passively with a YAG colorcenter chip has been deveolped. The Q-switched pulse output has a duration of 25-70ns,an energy of about 7.9 μJ and a repetition frequency of 1.25-5.0kHz when the laser cavityparameters and pump power are changed. The Q-switched dynamics is analyzed with therate equation theorry. The theoretical and experimental results agree well.
文摘YAG laser welding with surface activating flux has been investigated, and the influencing factors and mechanism are discussed. The results show that both surface activating flux and surface active element S have fantastic effects on the YAG laser weld shape, that is to obviously increase the weld penetration and D/W ratio in various welding conditions. The mechanism is thought to be the change of weld pool surface tension temperature coefficient, thus, the change of fluid flow pattern in weld pool due to the flux.
文摘This study compared the efficacy of 70- and 120-w 2-μm thulium:YAG VapoEnucleation of the prostate (ThuVEP) for patients with benign prostatic obstruction (BPO). A prospective analysis of 84 patients with symptomatic BPO and prostatic enlargement (t〉 60 ml) who underwent either 70-w (n=44) or 120-w ThuVEP (n=40) non-randomly was carried out. Patient demographics and perioperative and 12-month follow-up data were analysed. The mean prostate volume was 79.90---27.49 ml in patients who had received 70-w ThuVEP, which was less than in those who had received 120-w ThuVEP (88.53+-25.10; P=0.033). The mean enucleation (resected weight/laser time, 2.16±1.21 g min-1 vs. 1.23±0.60 g min-1; P=-0.013), operation efficiency (resected weight/total operation time, 0.76±0.35 g min-1 vs. 0.42+-0.27 g min-1; P=-0.000) and percentage of resected tissue (66.93%±22.79% vs. 45.41%±23.33%; P=-0.000) were higher with 120-w treatment compared to 70-w ThuVEP. One patient (1.2% of total patients) (in the 120-w group) required a blood transfusion postoperatively. Sixty-one patients (73%) were available for review at the 12-month follow-up time point. The quality of life (QoL), International Prostate Symptom Score (IPSS), maximum urinary flow rate (Qmax), postvoiding residual urine (PVR) and prostate volume improved significantly after treatment (P≤ 0.035) and were not significantly different between those treated with the different devices (70- and 120-w). The median prostate volume reduction was 81.70% and 82.19% with 70- and 120-w ThuVEP, respectively. The incidence of complications was low and did not differ between groups treated with the different devices. Two patients (2.4%) (one per group) had a bladder neck contracture at the follow-up. ThuVEP is a safe and efficacious procedure for the treatment of symptomatic BPO. The incidence of complications was low with both devices. The 120-w thulium:YAG device enhances the effectiveness of Th,VEP with reeard to the oercentaee of resected tissue and the enucleation/ooeration efficiency.
文摘AIM:To investigate the effects of a new opening pattern in neodymium:yttrium-aluminum-garnet(Nd:YAG)laser posterior capsulotomy on visual function.METHODS:This technique was conducted along a circular pattern.The energy ranged between 0.8 and1.2 mJ/pulse was consumed and mean total energy levels were 74±21 mJ(mean±standard deviation:SD,from 40 to167)and laser shots aimed at 150μm away behind a datum point and went along an imaginary line which extends 0.5 mm inside from optic margin and into the circular en bloc pattern.Vitreous stands were attached with fragment and then they were cut off by the laser after circular application.The circular fragment was completely separated from vitreous,and then this fragment was quickly sunk in intravitreal space.RESULTS:The follow-up period ranges from at least a week to 40mo,making 15.8mo on average.The procedural outcome showed 96%(74 eyes out of the 77eyes)enhancement in patients’visual acuity.Cystoid macular edema or retinal detachment was not observed in any of the patients during follow-up periods.CONCLUSION:This new technique is expected to improve the weaknesses that the conventional procedures have by adding the process to cut off vitreous stands attached with the fragment by the laser to the circular application.