The article introduces a finite element procedure using the bilinear quadrilateral element or four-node rectangular element(namely Q4 element) based on a refined first-order shear deformation theory(rFSDT) and Monte C...The article introduces a finite element procedure using the bilinear quadrilateral element or four-node rectangular element(namely Q4 element) based on a refined first-order shear deformation theory(rFSDT) and Monte Carlo simulation(MCS), so-called refined stochastic finite element method to investigate the random vibration of functionally graded material(FGM) plates subjected to the moving load.The advantage of the proposed method is to use r-FSDT to improve the accuracy of classical FSDT, satisfy the stress-free condition at the plate boundaries, and combine with MCS to analyze the vibration of the FGM plate when the parameter inputs are random quantities following a normal distribution. The obtained results show that the distribution characteristics of the vibration response of the FGM plate depend on the standard deviation of the input parameters and the velocity of the moving load.Furthermore, the numerical results in this study are expected to contribute to improving the understanding of FGM plates subjected to moving loads with uncertain input parameters.展开更多
In this study,a coupling model of fluid-conveying pipes made of functionally graded materials(FGMs)with NiTiNOL-steel(NiTi-ST)for vibration absorption is investigated.The vibration responses of the FGM fluid-conveying...In this study,a coupling model of fluid-conveying pipes made of functionally graded materials(FGMs)with NiTiNOL-steel(NiTi-ST)for vibration absorption is investigated.The vibration responses of the FGM fluid-conveying pipe with NiTi-ST are studied by the Galerkin truncation method(GTM)and harmonic balance method(HBM).The harmonic balance solutions and the numerical results are consistent.Also,the linearized stability of the structure is determined.The effects of the structure parameters on the absorption performance are also studied.The results show that the NiTi-ST is an effective means of vibration absorption.Furthermore,in studying the effect of the NiTi-ST,a closed detached response(CDR)is first observed.It is noteworthy that the CDR may dramatically change the vibration amplitude and that the parameters of the NiTi-ST may determine the emergence or disappearance of the CDR.This vibration absorption device can be extended to offer more general vibration control in engineering applications.展开更多
FGM渗漏水检测技术具有检测迅速、检测精度高,且不损害建(构)筑物的特点。从F G M技术检测渗漏水的工作原理展开阐述,并以南京某项目工程为例,从现场传感器布设、数据检测、以及采取针对性修补措施等方面介绍了如何运用FGM技术检测地下...FGM渗漏水检测技术具有检测迅速、检测精度高,且不损害建(构)筑物的特点。从F G M技术检测渗漏水的工作原理展开阐述,并以南京某项目工程为例,从现场传感器布设、数据检测、以及采取针对性修补措施等方面介绍了如何运用FGM技术检测地下连续墙渗漏水。实际结果表明,运用该检测技术可以在一定范围内精确查找到渗漏水出现的位置,提前预测并防治,以提高基坑施工的安全性。展开更多
文摘The article introduces a finite element procedure using the bilinear quadrilateral element or four-node rectangular element(namely Q4 element) based on a refined first-order shear deformation theory(rFSDT) and Monte Carlo simulation(MCS), so-called refined stochastic finite element method to investigate the random vibration of functionally graded material(FGM) plates subjected to the moving load.The advantage of the proposed method is to use r-FSDT to improve the accuracy of classical FSDT, satisfy the stress-free condition at the plate boundaries, and combine with MCS to analyze the vibration of the FGM plate when the parameter inputs are random quantities following a normal distribution. The obtained results show that the distribution characteristics of the vibration response of the FGM plate depend on the standard deviation of the input parameters and the velocity of the moving load.Furthermore, the numerical results in this study are expected to contribute to improving the understanding of FGM plates subjected to moving loads with uncertain input parameters.
基金Project supported by the National Natural Science Foundation of China(Nos.12272240 and12022213)。
文摘In this study,a coupling model of fluid-conveying pipes made of functionally graded materials(FGMs)with NiTiNOL-steel(NiTi-ST)for vibration absorption is investigated.The vibration responses of the FGM fluid-conveying pipe with NiTi-ST are studied by the Galerkin truncation method(GTM)and harmonic balance method(HBM).The harmonic balance solutions and the numerical results are consistent.Also,the linearized stability of the structure is determined.The effects of the structure parameters on the absorption performance are also studied.The results show that the NiTi-ST is an effective means of vibration absorption.Furthermore,in studying the effect of the NiTi-ST,a closed detached response(CDR)is first observed.It is noteworthy that the CDR may dramatically change the vibration amplitude and that the parameters of the NiTi-ST may determine the emergence or disappearance of the CDR.This vibration absorption device can be extended to offer more general vibration control in engineering applications.
文摘FGM渗漏水检测技术具有检测迅速、检测精度高,且不损害建(构)筑物的特点。从F G M技术检测渗漏水的工作原理展开阐述,并以南京某项目工程为例,从现场传感器布设、数据检测、以及采取针对性修补措施等方面介绍了如何运用FGM技术检测地下连续墙渗漏水。实际结果表明,运用该检测技术可以在一定范围内精确查找到渗漏水出现的位置,提前预测并防治,以提高基坑施工的安全性。