Effects of working parameters on performance characteristics of hydrostatic turntable are researched by applying the fluid-structure-thermal coupled model.Fluid-structure interaction(FSI)technique and computational fl...Effects of working parameters on performance characteristics of hydrostatic turntable are researched by applying the fluid-structure-thermal coupled model.Fluid-structure interaction(FSI)technique and computational fluid dynamics(CFD)method are both employed by this new model,and thermal effects are also considered.Hydrostatic turntable systems with a series of oil supply pressures,various oil recess depth and several surface roughness parameters are studied.Performance parameters,such as turntable displacement,system flow rate,temperature rise of lubrication,stiffness and damping coefficients,are derived from different working parameters(rotational speed of turntable and exerted external load)of the hydrostatic turntable.Numerical results obtained from this FSI-thermal model are presented and discussed,and theoretical predictions are in good agreement with the experimental data.Therefore,this developed model is a very useful tool for studying hydrostatic turntables.The calculation results show that in order to obtain better performance,a rational selection of the design parameters is essential.展开更多
In this paper,authors have discussed predominately unidirectional Fluid Structure Interaction,i. e. a given field in which a high speed/pressure and high temperature thermal flow affect the interface between pipelines...In this paper,authors have discussed predominately unidirectional Fluid Structure Interaction,i. e. a given field in which a high speed/pressure and high temperature thermal flow affect the interface between pipelines joints. Surface forces at the fluid-structure interface allow designers to investigate the effects of fluid flow on the structural deformation and stresses. Possible failure modes have been compared with different loads from steady thermal flow analysis results. CFD code SC/Tetra and FEA code ANSYS are used in this study. These studies can be used in protecting certain fatigue failures for pipeline joints under critical cyclic load conditions from both thermal expansion and hydraulic pressure in municipal and environmental engineering applications as well as oil and gas fields.展开更多
This paper presents a monolithic approach to the thermal fluidstructure interaction (FSI) with nonconforming interfaces. The thermal viscous flow is governed by the Boussinesq approximation and the incompressible Na...This paper presents a monolithic approach to the thermal fluidstructure interaction (FSI) with nonconforming interfaces. The thermal viscous flow is governed by the Boussinesq approximation and the incompressible NavierStokes equations. The motion of the fluid domain is accounted for by an arbitrary LagrangianEulerian (ALE) strategy. A pseudosolid formulation is used to manage the deformation of the fluid do main. The structure is described by the geometrically nonlinear thermoelastic dynamics. An efficient data transfer strategy based on the Gauss points is proposed to guarantee the equilibrium of the stresses and heat along the interface. The resulting strongly coupled set of nonlinear equations for the fluid, solution procedure. A numerical example efficiency of the methodology. structure, and heat is solved by a monolithic is presented to demonstrate the robustness and展开更多
基金Projects (51175518,51705147) supported by the National Natural Science Foundation of China
文摘Effects of working parameters on performance characteristics of hydrostatic turntable are researched by applying the fluid-structure-thermal coupled model.Fluid-structure interaction(FSI)technique and computational fluid dynamics(CFD)method are both employed by this new model,and thermal effects are also considered.Hydrostatic turntable systems with a series of oil supply pressures,various oil recess depth and several surface roughness parameters are studied.Performance parameters,such as turntable displacement,system flow rate,temperature rise of lubrication,stiffness and damping coefficients,are derived from different working parameters(rotational speed of turntable and exerted external load)of the hydrostatic turntable.Numerical results obtained from this FSI-thermal model are presented and discussed,and theoretical predictions are in good agreement with the experimental data.Therefore,this developed model is a very useful tool for studying hydrostatic turntables.The calculation results show that in order to obtain better performance,a rational selection of the design parameters is essential.
文摘In this paper,authors have discussed predominately unidirectional Fluid Structure Interaction,i. e. a given field in which a high speed/pressure and high temperature thermal flow affect the interface between pipelines joints. Surface forces at the fluid-structure interface allow designers to investigate the effects of fluid flow on the structural deformation and stresses. Possible failure modes have been compared with different loads from steady thermal flow analysis results. CFD code SC/Tetra and FEA code ANSYS are used in this study. These studies can be used in protecting certain fatigue failures for pipeline joints under critical cyclic load conditions from both thermal expansion and hydraulic pressure in municipal and environmental engineering applications as well as oil and gas fields.
文摘This paper presents a monolithic approach to the thermal fluidstructure interaction (FSI) with nonconforming interfaces. The thermal viscous flow is governed by the Boussinesq approximation and the incompressible NavierStokes equations. The motion of the fluid domain is accounted for by an arbitrary LagrangianEulerian (ALE) strategy. A pseudosolid formulation is used to manage the deformation of the fluid do main. The structure is described by the geometrically nonlinear thermoelastic dynamics. An efficient data transfer strategy based on the Gauss points is proposed to guarantee the equilibrium of the stresses and heat along the interface. The resulting strongly coupled set of nonlinear equations for the fluid, solution procedure. A numerical example efficiency of the methodology. structure, and heat is solved by a monolithic is presented to demonstrate the robustness and