Traditional laparoscopic liver cancer resection faces challenges,such as difficultiesin tumor localization and accurate marking of liver segments,as well as theinability to provide real-time intraoperative navigation....Traditional laparoscopic liver cancer resection faces challenges,such as difficultiesin tumor localization and accurate marking of liver segments,as well as theinability to provide real-time intraoperative navigation.This approach falls shortof meeting the demands for precise and anatomical liver resection.The introductionof fluorescence imaging technology,particularly indocyanine green,hasdemonstrated significant advantages in visualizing bile ducts,tumor localization,segment staining,microscopic lesion display,margin examination,and lymphnode visualization.This technology addresses the inherent limitations oftraditional laparoscopy,which lacks direct tactile feedback,and is increasinglybecoming the standard in laparoscopic procedures.Guided by fluorescenceimaging technology,laparoscopic liver cancer resection is poised to become thepredominant technique for liver tumor removal,enhancing the accuracy,safetyand efficiency of the procedure.展开更多
BACKGROUND Gastric cancer is a common malignant tumor of the digestive system worldwide,and its early diagnosis is crucial to improve the survival rate of patients.Indocyanine green fluorescence imaging(ICG-FI),as a n...BACKGROUND Gastric cancer is a common malignant tumor of the digestive system worldwide,and its early diagnosis is crucial to improve the survival rate of patients.Indocyanine green fluorescence imaging(ICG-FI),as a new imaging technology,has shown potential application prospects in oncology surgery.The meta-analysis to study the application value of ICG-FI in the diagnosis of gastric cancer sentinel lymph node biopsy is helpful to comprehensively evaluate the clinical effect of this technology and provide more reliable guidance for clinical practice.AIM To assess the diagnostic efficacy of optical imaging in conjunction with indocya-nine green(ICG)-guided sentinel lymph node(SLN)biopsy for gastric cancer.METHODS Electronic databases such as PubMed,Embase,Medline,Web of Science,and the Cochrane Library were searched for prospective diagnostic tests of optical imaging combined with ICG-guided SLN biopsy.Stata 12.0 software was used for analysis by combining the"bivariable mixed effect model"with the"midas"command.The true positive value,false positive value,false negative value,true negative value,and other information from the included literature were extracted.A literature quality assessment map was drawn to describe the overall quality of the included literature.A forest plot was used for heterogeneity analysis,and P<0.01 was considered to indicate statistical significance.A funnel plot was used to assess publication bias,and P<0.1 was considered to indicate statistical significance.The summary receiver operating characteristic(SROC)curve was used to calculate the area under the curve(AUC)to determine the diagnostic accuracy.If there was interstudy heterogeneity(I2>50%),meta-regression analysis and subgroup analysis were performed.analysis were performed.RESULTS Optical imaging involves two methods:Near-infrared(NIR)imaging and fluorescence imaging.A combination of optical imaging and ICG-guided SLN biopsy was useful for diagnosis.The positive likelihood ratio was 30.39(95%CI:0.92-1.00),the sensitivity was 0.95(95%CI:0.82-0.99),and the specificity was 1.00(95%CI:0.92-1.00).The negative likelihood ratio was 0.05(95%CI:0.01-0.20),the diagnostic odds ratio was 225.54(95%CI:88.81-572.77),and the SROC AUC was 1.00(95%CI:The crucial values were sensitivity=0.95(95%CI:0.82-0.99)and specificity=1.00(95%CI:0.92-1.00).The Deeks method revealed that the"diagnostic odds ratio"funnel plot of SLN biopsy for gastric cancer was significantly asymmetrical(P=0.01),suggesting significant publication bias.Further meta-subgroup analysis revealed that,compared with fluorescence imaging,NIR imaging had greater sensitivity(0.98 vs 0.73).Compared with optical imaging immediately after ICG injection,optical imaging after 20 minutes obtained greater sensitivity(0.98 vs 0.70).Compared with that of patients with an average SLN detection number<4,the sensitivity of patients with a SLN detection number≥4 was greater(0.96 vs 0.68).Compared with hematoxylin-eosin(HE)staining,immunohistochemical(+HE)staining showed greater sensitivity(0.99 vs 0.84).Compared with subserous injection of ICG,submucosal injection achieved greater sensitivity(0.98 vs 0.40).Compared with 5 g/L ICG,0.5 and 0.05 g/L ICG had greater sensitivity(0.98 vs 0.83),and cT1 stage had greater sensitivity(0.96 vs 0.72)than cT2 to cT3 clinical stage.Compared with that of patients≤26,the sensitivity of patients>26 was greater(0.96 vs 0.65).Compared with the literature published before 2010,the sensitivity of the literature published after 2010 was greater(0.97 vs 0.81),and the differences were statistically significant(all P<0.05).CONCLUSION For the diagnosis of stomach cancer,optical imaging in conjunction with ICG-guided SLN biopsy is a therapeut-ically viable approach,especially for early gastric cancer.The concentration of ICG used in the SLN biopsy of gastric cancer may be too high.Moreover,NIR imaging is better than fluorescence imaging and may obtain higher sensitivity.展开更多
Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical...Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical interventions, its moderate investment and operating costs and its portability. Although the technology is now mature, there is currently the problem of the availability of contrast agents to be injected IV. The aim of this methodology article is to propose an alternative solution to the need for contrast agents for clinical research, particularly in oncology. Methodology: They consist of coupling a fluorescent marker in the form of an NHS derivative, such as IR DYE manufactured in compliance with GMP, with therapeutic monoclonal antibodies having marketing authorization for molecular imaging. For a given antibody, the marking procedure must be the subject of a validation file on the final preparation filtered on a sterilizing membrane at 0.22 μm. Once the procedure has been validated, it would be unnecessary to repeat the tests before each clinical research examination. A check of the marking by thin-layer chromatography (TLC) and place it in a sample bank at +4˚C for 1 month of each injected formulation would be sufficient for additional tests if necessary. Conclusion: Molecular near-infrared fluorescence imaging is experiencing development, the process of which could be accelerated by greater availability of clinical contrast agents. Alternative solutions are therefore necessary to promote clinical research in this area. These methods must be shared to make it easier for researchers.展开更多
The automatic and accurate identification of apoptosis facilitates large-scale cell analysis.Most identification approaches using nucleus fluorescence imaging are based on specific morphological parameters.However,the...The automatic and accurate identification of apoptosis facilitates large-scale cell analysis.Most identification approaches using nucleus fluorescence imaging are based on specific morphological parameters.However,these parameters cannot completely describe nuclear morphology,thus limiting the identification accuracy of models.This paper proposes a new feature extraction method to improve the performance of the model for apoptosis identification.The proposed method uses a histogram of oriented gradient(HOG)of high-frequency wavelet coefficients to extract internal and edge texture information.The HOG vectors are classified using support vector machine.The experimental results demonstrate that the proposed feature extraction method well performs apoptosis identification,attaining 95:7% accuracy with low cost in terms of time.We confirmed that our method has potential applications to cell biology research.展开更多
The miniaturized femtosecond laser in near infrared-Ⅱregion is the core equipment of threephoton microscopy.In this paper,we design a compact and robust illumination source that emits dual-color linearly polarized li...The miniaturized femtosecond laser in near infrared-Ⅱregion is the core equipment of threephoton microscopy.In this paper,we design a compact and robust illumination source that emits dual-color linearly polarized light for three-photon microscopy.Based on an all-polarizationmaintaining passive mode-locked fiber laser,we shift the center wavelength of the pulses to the 1.7m band utilizing cascade Raman effect,thereby generate dual-wavelength pulses.To enhance clarity,the two wavelengths are separated through the graded-index multimode fiber.Then we obtain the dual-pulse sequences with 1639.4 nm and 1683.7 nm wavelengths,920 fs pulse duration,and 23.75 MHz pulse repetition rate.The average power of the signal is 53.64mW,corresponding to a single pulse energy of 2.25 nJ.This illumination source can be further amplified and compressed for three-photon fluorescence imaging,especially dual-color three-photon fluorescence imaging,making it an ideal option for biomedical applications.展开更多
[Objective] This study was to determine the response of Ficus microcarpa L. foliage to polyethylene glycol (PEG) simulated water stress using chlorophyll fluo- rescence imaging technique. [Method] The responses of d...[Objective] This study was to determine the response of Ficus microcarpa L. foliage to polyethylene glycol (PEG) simulated water stress using chlorophyll fluo- rescence imaging technique. [Method] The responses of detached leaves from Ficus microcarpa, Ficus benjamina and Nerium oleander to PEG-6000 simulated water stress were detected, and the chlorophyll fluorescence imaging technique was used to detect and analyze the stress at different spots of a single leaf simultaneously. [Result] The responses of Ficus microcarpa, Ficus benjamina and Nerium oleander to dehydration showed that: ~1~) the maximal photochemical efficiency (Fv/Fm) and non- photo-chemical quenching (NPQ) values were small in the reaction center among different detected spots of leaves, and there were great differences between relative electron transport rate (ETR), photochemical quenching (qP) and quantum efficiency of PSII photochemistry ((φPSII); (2) the differences of these parameters were more ob- vious among different spots of water-stressed leaves; (3) the discrete degrees of the species with strong resitances decreased significantly. [Conclusion] This study lays the foundation for the further research on the response of plants to drought stress using chlorophyll fluorescence imaging technique.展开更多
Indocyanine green(ICG)fluorescence imaging is widely used in abdominal surgery.The implementation of minimally invasive rectal surgery using new methods like robotics or a transanal approach required improvement of op...Indocyanine green(ICG)fluorescence imaging is widely used in abdominal surgery.The implementation of minimally invasive rectal surgery using new methods like robotics or a transanal approach required improvement of optical systems.In that setting,ICG fluorescence optimizes intraoperative vision of anatomical structures by improving blood and lymphatic flow.The purpose of this review was to summarize all potential applications of this upcoming technology in rectal cancer surgery.Each type of use has been separately addressed and the evidence was investigated.During rectal resection,ICG fluorescence angiography is mainly used to evaluate the perfusion of the colonic stump in order to reduce the risk of anastomotic leaks.In addition,ICG fluorescence imaging allows easy visualization of organs such as the ureter or urethra to protect them from injury.This intraoperative technology is a valuable tool for conducting lymph node dissection along the iliac lymphatic chain or to better identifying the rectal dissection planes when a transanal approach is performed.This is an overview of the applications of ICG fluorescence imaging in current surgical practice and a synthesis of the results obtained from the literature.Although further studies are need to investigate the real clinical benefits,these findings may enhance use of ICG fluorescence in current clinical practice and stimulate future research on new applications.展开更多
The aim of this research was to study the influence of chlorsulfuron residue and cadmium on the enzymatic activity and photosynthetic apparatus of maize(Zea mays L.) plants. Chlorsulfuron and cadmium at 0.001 and 5.0 ...The aim of this research was to study the influence of chlorsulfuron residue and cadmium on the enzymatic activity and photosynthetic apparatus of maize(Zea mays L.) plants. Chlorsulfuron and cadmium at 0.001 and 5.0 mg kg–1, respectively, were mixed and applied to soil prior to planting. The levels of chlorsulfuron-and cadmium-induced stress to plants were estimated by growth, chlorophyll content, lipid peroxide content, enzyme activities, and major fluorescence parameters of chlorophyll(revealed by the fluorescence imaging system Fluor Cam). Chlorsulfuron negatively affected the chlorophyll content, photochemical efficiency of photosystem II in the dark-adapted state, the maximum efficiency of photosystem II, photochemical quenching coefficient, and steady-state fluorescence decline ratio in the leaves of maize seedlings. However, cadmium did not produce noticeable changes. Plants that were exposed to both chlorsulfuron and cadmium showed an obvious increase in the steady-state fluorescence decline ratio. These results implied that the seedlings possessed more resistance to cadmium than to chlorsulfuron and their resistance to chlorsulfuron toxicity was enhanced by the presence of cadmium. The results also suggested that chlorophyll fluorescence imaging reveals overall alterations within the leaves but may not reflect small-scale effects on tissues, as numeric values of specific parameters are averages of the data collected from the whole leaf.展开更多
Surgery is still the primary curative treatment for gastric cancer,which includes resection of the tumor with adequate margins and extended lymphadenectomy.In order to improve the operative results and the quality of ...Surgery is still the primary curative treatment for gastric cancer,which includes resection of the tumor with adequate margins and extended lymphadenectomy.In order to improve the operative results and the quality of life of patients,several endeavors have been made toward precision medicine through image-guided surgery,allowing access to real-time intraoperative anatomy and accurate tumor staging.The goal of the surgeon is to achieve a more precise,individualized,and less invasive surgery without compromising oncological efficiency and safety.In this perspective,we have demonstrated the role of indocyanine green(ICG)and near-infrared(NIR)fluorescence imaging method in gastric cancer surgery.This technique may be used to improve localization of the tumor,detection of sentinel lymph nodes(SLN),real-time lymphatic mapping,and blood flow assessment(anastomosis perfusion).展开更多
Fluorescence imaging can provide valuable information on the expression,distribution,and activity of drug target proteins.Chemical probes are useful small-molecule tools for fluorescence imaging with high structural f...Fluorescence imaging can provide valuable information on the expression,distribution,and activity of drug target proteins.Chemical probes are useful small-molecule tools for fluorescence imaging with high structural flexibility and biocompatibility.In this review,we briefly introduce two classes of fluorescent probes for the visualization of drug target proteins.Enzymatically activatable probes make use of the specific enzymatic transformations that generally produce a fluorogenic response upon reacting with target enzymes.Alternatively,specific imaging can be conferred with a ligand that drives the probes to target proteins,where the labeling relies on noncovalent binding,covalent inhibition,or traceless labeling by ligand-directed chemistry.展开更多
Near infrared(NIR)fluorescence imaging guided photodynamic therapy(PDT)is a technique which has been developed in many clinical trials due to its advantage of real-time optical monitoring,specific spatiotemporal selec...Near infrared(NIR)fluorescence imaging guided photodynamic therapy(PDT)is a technique which has been developed in many clinical trials due to its advantage of real-time optical monitoring,specific spatiotemporal selectivity,and minimal invasiveness.For this,photosensitizers with NIR fluorescence emission and high^(1)O_(2)generation quantum yield are highly desirable.Herein,we designed and synthesized a"donor-acceptor"(D-A)structured semiconductor polymer(SP),which was then wrapped with an amphiphilic compound(Pluronic■F127)to prepare water-soluble nanoparticles(F-SP NPs).The obtained F-SP NPs exhibit good water solubility,excellent particle size stability,strong absorbance at deep red region,and strong NIR fluorescent emission characteristics.The maximal mass extinction coe±cient and fluorescence quantum yield of these F-SPs were calculated to be 21.7 L/(g·cm)and 6.5%,respectively.Moreover,the^(1)O_(2)quantum yield of 89%for F-SP NPs has been achieved under 635 nm laser irradiation,which is higher than Methylene Blue,Ce6,and PpIX.The outstanding properties of these F-SP NPs originate from their unique D-A molecular characteristic.This work should help guide the design of novel semiconductor polymer for NIR fluorescent imaging guided PDT applications.展开更多
Nitric oxide(NO)is a second messenger playing crucial roles in the signaling of a variety of cellular functions.Due to its pathophysiological significance,various NO modulators have been developed to explore NO pathwa...Nitric oxide(NO)is a second messenger playing crucial roles in the signaling of a variety of cellular functions.Due to its pathophysiological significance,various NO modulators have been developed to explore NO pathways and some have been used as therapies.These modulators are often used directly to observe pharmacological effects in cell lines,but their actual effect on intracellular NO level is seldom analyzed.Herein,facilitated by a selective and sensitive fluorescence probe,we observed that some NO modulators displayed unexpected behaviors with both NO scavenger carboxy-PTIO and endothelial nitric oxide synthase(eNOS)inhibitor N(u)-nitro-L-arginine methyl ester(L-NAME)failing to decrease intracellular free NO level in EA.hy926 cells while NO donor diethylamine-NONOate(DEA$NONOate)and eNOS activator calcimycin(A23187)failing to increase free NO level in human umbilical vein endothelial cell line(HUV-EC-C),although the reagents were confirmed to work normally in the primary human umbilical vein endothelial cells(primary HUVECs)and RAW 264.7 macrophage cells.Further research suggested that these unusual behaviors might be attributed to the cellular microenvironments including both the NO synthase(NOS)level and the endogenous glutathione(GSH)level.Genetically manipulating eNOS level in both cells restores the expected response,while decreasing GSH level restores the ability of DEA$NONOate to increase NO level in HUV-EC-C.These results reveal that the cellular microenvironment has a profound impact on pharmacological effect.Our study suggests GSH as a reservoir for NO in live cells and highlights the value of chemical probes as valuable tools to reveal microenvironmentdependent pharmacological effects.展开更多
Integrin molecules are transmembraneαβheterodimers involved in cell adhesion,trafficking,and signaling.Upon activation,integrins undergo dynamic conformational changes that regulate their affinity to ligands.The phy...Integrin molecules are transmembraneαβheterodimers involved in cell adhesion,trafficking,and signaling.Upon activation,integrins undergo dynamic conformational changes that regulate their affinity to ligands.The physiological functions and activation mechanisms of integrins have been heavily discussed in previous studies and reviews,but the fluorescence imaging techniques-which are powerful tools for biological studies-have not.Here we review the fluorescence labeling methods,imaging techniques,as well as Förster resonance energy transfer assays used to study integrin expression,localization,activation,and functions.展开更多
BACKGROUND Rectal prolapse in young women is rare.Although laparoscopic ventral mesh rectopexy is the standard procedure because of its lower recurrence rate,postoperative infertility is a concern.Perineal rectosigmoi...BACKGROUND Rectal prolapse in young women is rare.Although laparoscopic ventral mesh rectopexy is the standard procedure because of its lower recurrence rate,postoperative infertility is a concern.Perineal rectosigmoidectomy(Altemeier procedure)is useful for these patients.However,the risk of anastomotic leakage should be considered.Recently,the usefulness of fluorescence imaging with indocyanine green(ICG)to prevent anastomotic leakage was reported.We report a case of an adolescent woman with complete rectal prolapse who underwent ICG fluorescence imaging-assisted Altemeier rectosigmoidectomy.CASE SUMMARY A 17-year-old woman who had a mental disorder was admitted to our hospital for treatment for water intoxication.The patient also suffered from rectal prolapse,approximately 3 mo before admission.She was referred to our surgical department because recurrent rectal prolapse could worsen her psychiatric disorder.Approximately 10 cm of complete rectal prolapse was observed.However,the mean maximum anal resting and constriction pressures were within normal limits on anorectal manometry.Because she had the desire to bear children in the future,she underwent Altemeier perineal rectosigmoidectomy to prevent surgery-related infertility.We performed ICG fluorescence imaging at the same time as surgery to reduce the risk of anastomotic leakage.Her postoperative course was uneventful,and the rectal prolapse was completely resolved.She continued to do well 18 mo after surgery,without recurrence of the rectal prolapse.CONCLUSION ICG fluorescence imaging-assisted Altemeier perineal rectosigmoidectomy is useful in preventing postoperative anastomotic leakage in young as well as elderly patients.展开更多
A new laser induced fluorescence imaging system used for detecting and locating the petroleum pollutants is presented. A unique feature of the system was using a combination of a frequency tripled Nd:YAG pulse laser ...A new laser induced fluorescence imaging system used for detecting and locating the petroleum pollutants is presented. A unique feature of the system was using a combination of a frequency tripled Nd:YAG pulse laser and an image intensified CCD camera as imaging detector. The delay time of the system and the exposure time of the CCD are controlled by a delay generator. Petroleum pollutants on various backgrounds had been detected and located by this system. This imaging technique provides a useful noninvasive approach for the detection of petroleum pollutants, which can be used in remote sensing.展开更多
BACKGROUND Splenic artery aneurysm(SAA)is a rare vascular lesion conventionally treated by resection or interventional therapy.The surgical procedure usually involves splenectomy,and interventional therapy may cause p...BACKGROUND Splenic artery aneurysm(SAA)is a rare vascular lesion conventionally treated by resection or interventional therapy.The surgical procedure usually involves splenectomy,and interventional therapy may cause post-embolization syndromes.Preservation of the spleen and its function is rarely reported during the management of SAA.CASE SUMMARY We report a patient with an asymptomatic SAA(3.5 cm in diameter),which was en-bloc resected laparoscopically using indocyanine green(ICG)fluorescence imaging to preserve the spleen and its function.CONCLUSION ICG fluorescence imaging for spleen preservation in laparoscopic SAA resection is safe and may be beneficial in avoiding splenectomy and maintaining splenic function.展开更多
Carbon monoxide(CO)is a vital intracellular gas messenger known for its cytoprotective and homeostatic properties.It plays a pivotal role in a myriad of biological processes.Therefore,the precise detection of CO is of...Carbon monoxide(CO)is a vital intracellular gas messenger known for its cytoprotective and homeostatic properties.It plays a pivotal role in a myriad of biological processes.Therefore,the precise detection of CO is of paramount importance in unraveling the intricacies of pathological mechanisms and advancing the development of disease diagnosis.We herein introduce NFCOP,a state-of-the-art near-infrared(NIR)turn-on fluorescence(FL)probe that has been meticulously designed for highly sensitive,swift and selective imaging of CO.The NFCOP response occurred rapidly with CO,within just 10 s,and the calculated detection limit for CO was determined to be 0.32μmol/L.Further investigations conducted at the cellular level and in vivo demonstrated that NFCOP possesses high sensitivity and selectivity for imaging CO.展开更多
Fluorescence imaging can be employed in fields of medical treatment,astronomical exploration,and national defense security.Traditional fluorescence imaging often takes the single-photon techniques,which is vulnerable ...Fluorescence imaging can be employed in fields of medical treatment,astronomical exploration,and national defense security.Traditional fluorescence imaging often takes the single-photon techniques,which is vulnerable to background interference and photobleaching.Remedially,two-photon fluorescence imaging can achieve much higher-resolution fluorescence imaging for reducing scattering and deeper depth.Hence,by assembling the tetraphenylethylene backbones with nontoxic and non-noble K^(+)ions,compound 1([(Hdma)K(H_(2)ettc)]_(n),H_(4)ettc=4',4''',4''''',4'''''''-(ethene-1,1,2,2-tetrayl)tetrakis(([1,1'-biphenyl]-4-carboxylic acid)))with the crystallization-induced emissions exhibited charming fluorescence imaging under two-photon excitation microscopy(TPEM).Besides,luminescent powders based on compound 1 can achieve high-resolution fingerprint recognition,providing secure access control and identification for a novel authentication method.Compared with the commercial fluorescent dyes coumarin-6,the as-synthesized compound 1 showed great solvent stability,indicating its durability against harsh environment.Moreover,compound 1 shows mechanoluminescent properties for the perturbation of weak supramolecular interactions within ordered arrangements of the H_(2)ettc^(2−)ligands.This novel compound has provided an important insight to the development of twophoton fluorescence imaging and advanced external-stimuli responsive materials.展开更多
Semiconducting polymer nanoparticles(SPNs)have shown great promise in second near-infrared window(NIR-II)phototheranostics.However,the issue of long metabolic time significantly restricts the clinical application of S...Semiconducting polymer nanoparticles(SPNs)have shown great promise in second near-infrared window(NIR-II)phototheranostics.However,the issue of long metabolic time significantly restricts the clinical application of SPNs.In this study,we rationally designed a biodegradable SPN(BSPN50)for NIR-II fluorescence imaging-guided photodynamic therapy(PDT).BSPN50 is prepared by encapsulating a biodegradable SP(BSP50)with an amphiphilic copolymer F-127.BSP50 is composed of NIR-II fluorescent diketopyrrolopyrrole(DPP)segment and degradable poly(phenylenevinylene)(PPV)segment with the ratio of 50/50.BSPN50 has both satisfactory degradability under myeloperoxidase(MPO)/hydrogen peroxide(H_(2)O_(2))and NIR-II fluorescence emission upon 808 nm laser excitation.Furthermore,BSPN50 shows good photodynamic efficacy under 808 nm laser irradiation.BSPN50 shows a faster degradation rate than BSPN100 which has no PPV segment both in vitro and in vivo.In addition,BSPN50 can effectively diagnose tumor via NIR-II fluorescence imaging and inhibit the tumor growth by PDT.Thus,our study provides a rational approach to construct biodegradable nanoplatforms for efficient tumor NIR-II phototheranostics.展开更多
Laparoscopic anatomical hepatectomy(LAH)for patients with hepatocellular carcinoma(HCC)has been advocated by many surgeons in the hope of producing better oncological outcomes.Two recent techniques,3D laparoscopic sys...Laparoscopic anatomical hepatectomy(LAH)for patients with hepatocellular carcinoma(HCC)has been advocated by many surgeons in the hope of producing better oncological outcomes.Two recent techniques,3D laparoscopic system and 2D real-time indocyanine green fluorescence imaging(r-ICG)guidance,are benefit for improving the operative precision of LAH in different aspects.However,these two techniques cannot be applied concomitantly because of the technical limitation.Although a new modern laparoscopic system with both 3D and indocyanine green(ICG)imaging mode has been designed,it has not been listed in many countries including China.Thus,we design a new procedure to perform the 3D LAH with 2D r-ICG guidance for HCCs with conventional laparoscopic systems.In this procedure,both 3D and 2D laparoscopic systems were used.A total of 11 patients with HCC received 3D laparoscopic right posterior sectionectomy(LRPS)with 2D r-ICG guidance.The right posterior Glissonian pedicle was clamped under the 3D vision.Then ICG solution was then intravenously administrated.The liver parenchyma was transected under the 3D vision and guided by 2D ICG vision simultaneously.There was no severe complications(Clavien-Dindo≥III)and operation related death.The 90-day mortality was also nil.By using this procedure,the advantages of two techniques,3D laparoscopic system and 2D r-ICG guidance,were combined so that LAH could be performed with more precision.However,it should be validated in more studies.展开更多
文摘Traditional laparoscopic liver cancer resection faces challenges,such as difficultiesin tumor localization and accurate marking of liver segments,as well as theinability to provide real-time intraoperative navigation.This approach falls shortof meeting the demands for precise and anatomical liver resection.The introductionof fluorescence imaging technology,particularly indocyanine green,hasdemonstrated significant advantages in visualizing bile ducts,tumor localization,segment staining,microscopic lesion display,margin examination,and lymphnode visualization.This technology addresses the inherent limitations oftraditional laparoscopy,which lacks direct tactile feedback,and is increasinglybecoming the standard in laparoscopic procedures.Guided by fluorescenceimaging technology,laparoscopic liver cancer resection is poised to become thepredominant technique for liver tumor removal,enhancing the accuracy,safetyand efficiency of the procedure.
文摘BACKGROUND Gastric cancer is a common malignant tumor of the digestive system worldwide,and its early diagnosis is crucial to improve the survival rate of patients.Indocyanine green fluorescence imaging(ICG-FI),as a new imaging technology,has shown potential application prospects in oncology surgery.The meta-analysis to study the application value of ICG-FI in the diagnosis of gastric cancer sentinel lymph node biopsy is helpful to comprehensively evaluate the clinical effect of this technology and provide more reliable guidance for clinical practice.AIM To assess the diagnostic efficacy of optical imaging in conjunction with indocya-nine green(ICG)-guided sentinel lymph node(SLN)biopsy for gastric cancer.METHODS Electronic databases such as PubMed,Embase,Medline,Web of Science,and the Cochrane Library were searched for prospective diagnostic tests of optical imaging combined with ICG-guided SLN biopsy.Stata 12.0 software was used for analysis by combining the"bivariable mixed effect model"with the"midas"command.The true positive value,false positive value,false negative value,true negative value,and other information from the included literature were extracted.A literature quality assessment map was drawn to describe the overall quality of the included literature.A forest plot was used for heterogeneity analysis,and P<0.01 was considered to indicate statistical significance.A funnel plot was used to assess publication bias,and P<0.1 was considered to indicate statistical significance.The summary receiver operating characteristic(SROC)curve was used to calculate the area under the curve(AUC)to determine the diagnostic accuracy.If there was interstudy heterogeneity(I2>50%),meta-regression analysis and subgroup analysis were performed.analysis were performed.RESULTS Optical imaging involves two methods:Near-infrared(NIR)imaging and fluorescence imaging.A combination of optical imaging and ICG-guided SLN biopsy was useful for diagnosis.The positive likelihood ratio was 30.39(95%CI:0.92-1.00),the sensitivity was 0.95(95%CI:0.82-0.99),and the specificity was 1.00(95%CI:0.92-1.00).The negative likelihood ratio was 0.05(95%CI:0.01-0.20),the diagnostic odds ratio was 225.54(95%CI:88.81-572.77),and the SROC AUC was 1.00(95%CI:The crucial values were sensitivity=0.95(95%CI:0.82-0.99)and specificity=1.00(95%CI:0.92-1.00).The Deeks method revealed that the"diagnostic odds ratio"funnel plot of SLN biopsy for gastric cancer was significantly asymmetrical(P=0.01),suggesting significant publication bias.Further meta-subgroup analysis revealed that,compared with fluorescence imaging,NIR imaging had greater sensitivity(0.98 vs 0.73).Compared with optical imaging immediately after ICG injection,optical imaging after 20 minutes obtained greater sensitivity(0.98 vs 0.70).Compared with that of patients with an average SLN detection number<4,the sensitivity of patients with a SLN detection number≥4 was greater(0.96 vs 0.68).Compared with hematoxylin-eosin(HE)staining,immunohistochemical(+HE)staining showed greater sensitivity(0.99 vs 0.84).Compared with subserous injection of ICG,submucosal injection achieved greater sensitivity(0.98 vs 0.40).Compared with 5 g/L ICG,0.5 and 0.05 g/L ICG had greater sensitivity(0.98 vs 0.83),and cT1 stage had greater sensitivity(0.96 vs 0.72)than cT2 to cT3 clinical stage.Compared with that of patients≤26,the sensitivity of patients>26 was greater(0.96 vs 0.65).Compared with the literature published before 2010,the sensitivity of the literature published after 2010 was greater(0.97 vs 0.81),and the differences were statistically significant(all P<0.05).CONCLUSION For the diagnosis of stomach cancer,optical imaging in conjunction with ICG-guided SLN biopsy is a therapeut-ically viable approach,especially for early gastric cancer.The concentration of ICG used in the SLN biopsy of gastric cancer may be too high.Moreover,NIR imaging is better than fluorescence imaging and may obtain higher sensitivity.
文摘Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical interventions, its moderate investment and operating costs and its portability. Although the technology is now mature, there is currently the problem of the availability of contrast agents to be injected IV. The aim of this methodology article is to propose an alternative solution to the need for contrast agents for clinical research, particularly in oncology. Methodology: They consist of coupling a fluorescent marker in the form of an NHS derivative, such as IR DYE manufactured in compliance with GMP, with therapeutic monoclonal antibodies having marketing authorization for molecular imaging. For a given antibody, the marking procedure must be the subject of a validation file on the final preparation filtered on a sterilizing membrane at 0.22 μm. Once the procedure has been validated, it would be unnecessary to repeat the tests before each clinical research examination. A check of the marking by thin-layer chromatography (TLC) and place it in a sample bank at +4˚C for 1 month of each injected formulation would be sufficient for additional tests if necessary. Conclusion: Molecular near-infrared fluorescence imaging is experiencing development, the process of which could be accelerated by greater availability of clinical contrast agents. Alternative solutions are therefore necessary to promote clinical research in this area. These methods must be shared to make it easier for researchers.
基金This work is supported by the Key Project of the National Natural Science Foundation of China(Grant Number 62135003)the Science and Technology Program of Guangzhou(Grant No.202201010704)Special Carrier Program of Qingyuan Hitech Industrial Development Zone.
文摘The automatic and accurate identification of apoptosis facilitates large-scale cell analysis.Most identification approaches using nucleus fluorescence imaging are based on specific morphological parameters.However,these parameters cannot completely describe nuclear morphology,thus limiting the identification accuracy of models.This paper proposes a new feature extraction method to improve the performance of the model for apoptosis identification.The proposed method uses a histogram of oriented gradient(HOG)of high-frequency wavelet coefficients to extract internal and edge texture information.The HOG vectors are classified using support vector machine.The experimental results demonstrate that the proposed feature extraction method well performs apoptosis identification,attaining 95:7% accuracy with low cost in terms of time.We confirmed that our method has potential applications to cell biology research.
基金supported by the Fundamental Re-search Funds for the Central Universities(HYGJXM202309).
文摘The miniaturized femtosecond laser in near infrared-Ⅱregion is the core equipment of threephoton microscopy.In this paper,we design a compact and robust illumination source that emits dual-color linearly polarized light for three-photon microscopy.Based on an all-polarizationmaintaining passive mode-locked fiber laser,we shift the center wavelength of the pulses to the 1.7m band utilizing cascade Raman effect,thereby generate dual-wavelength pulses.To enhance clarity,the two wavelengths are separated through the graded-index multimode fiber.Then we obtain the dual-pulse sequences with 1639.4 nm and 1683.7 nm wavelengths,920 fs pulse duration,and 23.75 MHz pulse repetition rate.The average power of the signal is 53.64mW,corresponding to a single pulse energy of 2.25 nJ.This illumination source can be further amplified and compressed for three-photon fluorescence imaging,especially dual-color three-photon fluorescence imaging,making it an ideal option for biomedical applications.
基金Supported by the Major Program for the West Action Projects of the Knowledge Innovation Program of the Chinese Academy of Sciences(KZCX2-XB2-08)the Science-Technology Foundation of Zealquest(ZQFD200705)~~
文摘[Objective] This study was to determine the response of Ficus microcarpa L. foliage to polyethylene glycol (PEG) simulated water stress using chlorophyll fluo- rescence imaging technique. [Method] The responses of detached leaves from Ficus microcarpa, Ficus benjamina and Nerium oleander to PEG-6000 simulated water stress were detected, and the chlorophyll fluorescence imaging technique was used to detect and analyze the stress at different spots of a single leaf simultaneously. [Result] The responses of Ficus microcarpa, Ficus benjamina and Nerium oleander to dehydration showed that: ~1~) the maximal photochemical efficiency (Fv/Fm) and non- photo-chemical quenching (NPQ) values were small in the reaction center among different detected spots of leaves, and there were great differences between relative electron transport rate (ETR), photochemical quenching (qP) and quantum efficiency of PSII photochemistry ((φPSII); (2) the differences of these parameters were more ob- vious among different spots of water-stressed leaves; (3) the discrete degrees of the species with strong resitances decreased significantly. [Conclusion] This study lays the foundation for the further research on the response of plants to drought stress using chlorophyll fluorescence imaging technique.
文摘Indocyanine green(ICG)fluorescence imaging is widely used in abdominal surgery.The implementation of minimally invasive rectal surgery using new methods like robotics or a transanal approach required improvement of optical systems.In that setting,ICG fluorescence optimizes intraoperative vision of anatomical structures by improving blood and lymphatic flow.The purpose of this review was to summarize all potential applications of this upcoming technology in rectal cancer surgery.Each type of use has been separately addressed and the evidence was investigated.During rectal resection,ICG fluorescence angiography is mainly used to evaluate the perfusion of the colonic stump in order to reduce the risk of anastomotic leaks.In addition,ICG fluorescence imaging allows easy visualization of organs such as the ureter or urethra to protect them from injury.This intraoperative technology is a valuable tool for conducting lymph node dissection along the iliac lymphatic chain or to better identifying the rectal dissection planes when a transanal approach is performed.This is an overview of the applications of ICG fluorescence imaging in current surgical practice and a synthesis of the results obtained from the literature.Although further studies are need to investigate the real clinical benefits,these findings may enhance use of ICG fluorescence in current clinical practice and stimulate future research on new applications.
基金supported by grants from the National Natural Science Foundation of China(30740037)the Special Fund for Agro-scientific Research in the Public Interest,China(201103024)the Foundation for Graduate Innovation,Shanxi University,China(011452901009)
文摘The aim of this research was to study the influence of chlorsulfuron residue and cadmium on the enzymatic activity and photosynthetic apparatus of maize(Zea mays L.) plants. Chlorsulfuron and cadmium at 0.001 and 5.0 mg kg–1, respectively, were mixed and applied to soil prior to planting. The levels of chlorsulfuron-and cadmium-induced stress to plants were estimated by growth, chlorophyll content, lipid peroxide content, enzyme activities, and major fluorescence parameters of chlorophyll(revealed by the fluorescence imaging system Fluor Cam). Chlorsulfuron negatively affected the chlorophyll content, photochemical efficiency of photosystem II in the dark-adapted state, the maximum efficiency of photosystem II, photochemical quenching coefficient, and steady-state fluorescence decline ratio in the leaves of maize seedlings. However, cadmium did not produce noticeable changes. Plants that were exposed to both chlorsulfuron and cadmium showed an obvious increase in the steady-state fluorescence decline ratio. These results implied that the seedlings possessed more resistance to cadmium than to chlorsulfuron and their resistance to chlorsulfuron toxicity was enhanced by the presence of cadmium. The results also suggested that chlorophyll fluorescence imaging reveals overall alterations within the leaves but may not reflect small-scale effects on tissues, as numeric values of specific parameters are averages of the data collected from the whole leaf.
文摘Surgery is still the primary curative treatment for gastric cancer,which includes resection of the tumor with adequate margins and extended lymphadenectomy.In order to improve the operative results and the quality of life of patients,several endeavors have been made toward precision medicine through image-guided surgery,allowing access to real-time intraoperative anatomy and accurate tumor staging.The goal of the surgeon is to achieve a more precise,individualized,and less invasive surgery without compromising oncological efficiency and safety.In this perspective,we have demonstrated the role of indocyanine green(ICG)and near-infrared(NIR)fluorescence imaging method in gastric cancer surgery.This technique may be used to improve localization of the tumor,detection of sentinel lymph nodes(SLN),real-time lymphatic mapping,and blood flow assessment(anastomosis perfusion).
基金This work was funded by Japan Science and Technology Agency(JST)ERATO Grant JPMJER1802 and a Grant-in-Aid for Scientific Research on Innovative Areas“Chemistry for Multimolecular Crowding Biosystems”(17H06348).
文摘Fluorescence imaging can provide valuable information on the expression,distribution,and activity of drug target proteins.Chemical probes are useful small-molecule tools for fluorescence imaging with high structural flexibility and biocompatibility.In this review,we briefly introduce two classes of fluorescent probes for the visualization of drug target proteins.Enzymatically activatable probes make use of the specific enzymatic transformations that generally produce a fluorogenic response upon reacting with target enzymes.Alternatively,specific imaging can be conferred with a ligand that drives the probes to target proteins,where the labeling relies on noncovalent binding,covalent inhibition,or traceless labeling by ligand-directed chemistry.
基金This work was supported by National Natural Science Foundation of China(Nos.61805287 and 62175262)The Open Fund of the State Key Laboratory of Luminescent Materials and Devices(South China University of Technology,No.2021-skllmd-10)+1 种基金The Open Sharing Fund for Large-scale Instruments and Equipment of Central South University(CSUZC202218),Fundamental Research Funds for the Central South Universities(Nos.2020CX021,2020zzts387,and 2020zzts404)Key R&D plan of Hunan Province(No.2022SK2101).
文摘Near infrared(NIR)fluorescence imaging guided photodynamic therapy(PDT)is a technique which has been developed in many clinical trials due to its advantage of real-time optical monitoring,specific spatiotemporal selectivity,and minimal invasiveness.For this,photosensitizers with NIR fluorescence emission and high^(1)O_(2)generation quantum yield are highly desirable.Herein,we designed and synthesized a"donor-acceptor"(D-A)structured semiconductor polymer(SP),which was then wrapped with an amphiphilic compound(Pluronic■F127)to prepare water-soluble nanoparticles(F-SP NPs).The obtained F-SP NPs exhibit good water solubility,excellent particle size stability,strong absorbance at deep red region,and strong NIR fluorescent emission characteristics.The maximal mass extinction coe±cient and fluorescence quantum yield of these F-SPs were calculated to be 21.7 L/(g·cm)and 6.5%,respectively.Moreover,the^(1)O_(2)quantum yield of 89%for F-SP NPs has been achieved under 635 nm laser irradiation,which is higher than Methylene Blue,Ce6,and PpIX.The outstanding properties of these F-SP NPs originate from their unique D-A molecular characteristic.This work should help guide the design of novel semiconductor polymer for NIR fluorescent imaging guided PDT applications.
基金We greatly appreciate the financial support from the National Natural Science Foundations of China(21778048,81673489,31871414,U1703235)the National Key R&D Program of China(2019ZX09201001-003-010)+1 种基金the Natural Science Foundation of Zhejiang Province,China(LR18H300001)Shanghai Science and Technology Development Funds(19YF1457500).
文摘Nitric oxide(NO)is a second messenger playing crucial roles in the signaling of a variety of cellular functions.Due to its pathophysiological significance,various NO modulators have been developed to explore NO pathways and some have been used as therapies.These modulators are often used directly to observe pharmacological effects in cell lines,but their actual effect on intracellular NO level is seldom analyzed.Herein,facilitated by a selective and sensitive fluorescence probe,we observed that some NO modulators displayed unexpected behaviors with both NO scavenger carboxy-PTIO and endothelial nitric oxide synthase(eNOS)inhibitor N(u)-nitro-L-arginine methyl ester(L-NAME)failing to decrease intracellular free NO level in EA.hy926 cells while NO donor diethylamine-NONOate(DEA$NONOate)and eNOS activator calcimycin(A23187)failing to increase free NO level in human umbilical vein endothelial cell line(HUV-EC-C),although the reagents were confirmed to work normally in the primary human umbilical vein endothelial cells(primary HUVECs)and RAW 264.7 macrophage cells.Further research suggested that these unusual behaviors might be attributed to the cellular microenvironments including both the NO synthase(NOS)level and the endogenous glutathione(GSH)level.Genetically manipulating eNOS level in both cells restores the expected response,while decreasing GSH level restores the ability of DEA$NONOate to increase NO level in HUV-EC-C.These results reveal that the cellular microenvironment has a profound impact on pharmacological effect.Our study suggests GSH as a reservoir for NO in live cells and highlights the value of chemical probes as valuable tools to reveal microenvironmentdependent pharmacological effects.
基金This work was supported by funding from the National Institutes of Health,USA(NIH,R01HL145454)a startup fund from UConn Health.
文摘Integrin molecules are transmembraneαβheterodimers involved in cell adhesion,trafficking,and signaling.Upon activation,integrins undergo dynamic conformational changes that regulate their affinity to ligands.The physiological functions and activation mechanisms of integrins have been heavily discussed in previous studies and reviews,but the fluorescence imaging techniques-which are powerful tools for biological studies-have not.Here we review the fluorescence labeling methods,imaging techniques,as well as Förster resonance energy transfer assays used to study integrin expression,localization,activation,and functions.
文摘BACKGROUND Rectal prolapse in young women is rare.Although laparoscopic ventral mesh rectopexy is the standard procedure because of its lower recurrence rate,postoperative infertility is a concern.Perineal rectosigmoidectomy(Altemeier procedure)is useful for these patients.However,the risk of anastomotic leakage should be considered.Recently,the usefulness of fluorescence imaging with indocyanine green(ICG)to prevent anastomotic leakage was reported.We report a case of an adolescent woman with complete rectal prolapse who underwent ICG fluorescence imaging-assisted Altemeier rectosigmoidectomy.CASE SUMMARY A 17-year-old woman who had a mental disorder was admitted to our hospital for treatment for water intoxication.The patient also suffered from rectal prolapse,approximately 3 mo before admission.She was referred to our surgical department because recurrent rectal prolapse could worsen her psychiatric disorder.Approximately 10 cm of complete rectal prolapse was observed.However,the mean maximum anal resting and constriction pressures were within normal limits on anorectal manometry.Because she had the desire to bear children in the future,she underwent Altemeier perineal rectosigmoidectomy to prevent surgery-related infertility.We performed ICG fluorescence imaging at the same time as surgery to reduce the risk of anastomotic leakage.Her postoperative course was uneventful,and the rectal prolapse was completely resolved.She continued to do well 18 mo after surgery,without recurrence of the rectal prolapse.CONCLUSION ICG fluorescence imaging-assisted Altemeier perineal rectosigmoidectomy is useful in preventing postoperative anastomotic leakage in young as well as elderly patients.
文摘A new laser induced fluorescence imaging system used for detecting and locating the petroleum pollutants is presented. A unique feature of the system was using a combination of a frequency tripled Nd:YAG pulse laser and an image intensified CCD camera as imaging detector. The delay time of the system and the exposure time of the CCD are controlled by a delay generator. Petroleum pollutants on various backgrounds had been detected and located by this system. This imaging technique provides a useful noninvasive approach for the detection of petroleum pollutants, which can be used in remote sensing.
基金Zhejiang Medical and Health Science and Technology Plan,No. 2022RC096Basic Public Welfare Research Project of Zhejiang Province of China,No. LGF20H030011
文摘BACKGROUND Splenic artery aneurysm(SAA)is a rare vascular lesion conventionally treated by resection or interventional therapy.The surgical procedure usually involves splenectomy,and interventional therapy may cause post-embolization syndromes.Preservation of the spleen and its function is rarely reported during the management of SAA.CASE SUMMARY We report a patient with an asymptomatic SAA(3.5 cm in diameter),which was en-bloc resected laparoscopically using indocyanine green(ICG)fluorescence imaging to preserve the spleen and its function.CONCLUSION ICG fluorescence imaging for spleen preservation in laparoscopic SAA resection is safe and may be beneficial in avoiding splenectomy and maintaining splenic function.
基金supported by the National Key R&D Programs(No.2021YFA0910001)the Shenzhen Science and Technology Program(Nos.JCYJ20210324115804013,JCYJ2022081810160716,JCYJ20220531093604009)+2 种基金the Specific Research Assistant Funding Program of Chinese Academy of Sciences(No.E35902)the National Natural Science Foundation of China(Nos.22005343,32000982)the Guangdong Provincial Key Area R&D Program(No.2020B1111540001).
文摘Carbon monoxide(CO)is a vital intracellular gas messenger known for its cytoprotective and homeostatic properties.It plays a pivotal role in a myriad of biological processes.Therefore,the precise detection of CO is of paramount importance in unraveling the intricacies of pathological mechanisms and advancing the development of disease diagnosis.We herein introduce NFCOP,a state-of-the-art near-infrared(NIR)turn-on fluorescence(FL)probe that has been meticulously designed for highly sensitive,swift and selective imaging of CO.The NFCOP response occurred rapidly with CO,within just 10 s,and the calculated detection limit for CO was determined to be 0.32μmol/L.Further investigations conducted at the cellular level and in vivo demonstrated that NFCOP possesses high sensitivity and selectivity for imaging CO.
基金supported by the National Natural Science Foundation of China(Nos.22205237,22271283,21971240,and 21827813)the National Key Research and Development Program of China(No.2017YFA0206802)the Scientific Instrument Developing Project of the Chinese Academy of Sciences(No.YJKYYQ20210039).
文摘Fluorescence imaging can be employed in fields of medical treatment,astronomical exploration,and national defense security.Traditional fluorescence imaging often takes the single-photon techniques,which is vulnerable to background interference and photobleaching.Remedially,two-photon fluorescence imaging can achieve much higher-resolution fluorescence imaging for reducing scattering and deeper depth.Hence,by assembling the tetraphenylethylene backbones with nontoxic and non-noble K^(+)ions,compound 1([(Hdma)K(H_(2)ettc)]_(n),H_(4)ettc=4',4''',4''''',4'''''''-(ethene-1,1,2,2-tetrayl)tetrakis(([1,1'-biphenyl]-4-carboxylic acid)))with the crystallization-induced emissions exhibited charming fluorescence imaging under two-photon excitation microscopy(TPEM).Besides,luminescent powders based on compound 1 can achieve high-resolution fingerprint recognition,providing secure access control and identification for a novel authentication method.Compared with the commercial fluorescent dyes coumarin-6,the as-synthesized compound 1 showed great solvent stability,indicating its durability against harsh environment.Moreover,compound 1 shows mechanoluminescent properties for the perturbation of weak supramolecular interactions within ordered arrangements of the H_(2)ettc^(2−)ligands.This novel compound has provided an important insight to the development of twophoton fluorescence imaging and advanced external-stimuli responsive materials.
基金the National Natural Science Foundation of China(Nos.22174070 and 22205115)Natural Science Foundation of Jiangsu Province(No.BK20230060)+4 种基金Natural Science Foundation of Jiangsu University(No.21KJB150022)the Research startup fund of NJUPT(No.NY220149)Natural Science Foundation of NJUPT(No.NY221088)the Project of State Key Laboratory of Organic Electronics and Information Displays,Nanjing University of Posts and Telecommunications(Nos.GZR2022010012 and GZR2023010022)the Synergetic Innovation Center for Organic Electronics and Information Displays for the financial support.
文摘Semiconducting polymer nanoparticles(SPNs)have shown great promise in second near-infrared window(NIR-II)phototheranostics.However,the issue of long metabolic time significantly restricts the clinical application of SPNs.In this study,we rationally designed a biodegradable SPN(BSPN50)for NIR-II fluorescence imaging-guided photodynamic therapy(PDT).BSPN50 is prepared by encapsulating a biodegradable SP(BSP50)with an amphiphilic copolymer F-127.BSP50 is composed of NIR-II fluorescent diketopyrrolopyrrole(DPP)segment and degradable poly(phenylenevinylene)(PPV)segment with the ratio of 50/50.BSPN50 has both satisfactory degradability under myeloperoxidase(MPO)/hydrogen peroxide(H_(2)O_(2))and NIR-II fluorescence emission upon 808 nm laser excitation.Furthermore,BSPN50 shows good photodynamic efficacy under 808 nm laser irradiation.BSPN50 shows a faster degradation rate than BSPN100 which has no PPV segment both in vitro and in vivo.In addition,BSPN50 can effectively diagnose tumor via NIR-II fluorescence imaging and inhibit the tumor growth by PDT.Thus,our study provides a rational approach to construct biodegradable nanoplatforms for efficient tumor NIR-II phototheranostics.
文摘Laparoscopic anatomical hepatectomy(LAH)for patients with hepatocellular carcinoma(HCC)has been advocated by many surgeons in the hope of producing better oncological outcomes.Two recent techniques,3D laparoscopic system and 2D real-time indocyanine green fluorescence imaging(r-ICG)guidance,are benefit for improving the operative precision of LAH in different aspects.However,these two techniques cannot be applied concomitantly because of the technical limitation.Although a new modern laparoscopic system with both 3D and indocyanine green(ICG)imaging mode has been designed,it has not been listed in many countries including China.Thus,we design a new procedure to perform the 3D LAH with 2D r-ICG guidance for HCCs with conventional laparoscopic systems.In this procedure,both 3D and 2D laparoscopic systems were used.A total of 11 patients with HCC received 3D laparoscopic right posterior sectionectomy(LRPS)with 2D r-ICG guidance.The right posterior Glissonian pedicle was clamped under the 3D vision.Then ICG solution was then intravenously administrated.The liver parenchyma was transected under the 3D vision and guided by 2D ICG vision simultaneously.There was no severe complications(Clavien-Dindo≥III)and operation related death.The 90-day mortality was also nil.By using this procedure,the advantages of two techniques,3D laparoscopic system and 2D r-ICG guidance,were combined so that LAH could be performed with more precision.However,it should be validated in more studies.