期刊文献+
共找到2,035篇文章
< 1 2 102 >
每页显示 20 50 100
Dynamic physical characteristics of DC arc on arcing horn for HVDC grounding electrode line
1
作者 刘益岑 杨晨光 +4 位作者 郭裕钧 张血琴 肖嵩 高国强 吴广宁 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第1期80-87,共8页
The dynamic physical characteristics of a DC arc on an arcing horn for a high voltage direct current(HVDC)grounding electrode line are significantly different from those of the switching device arc,secondary arc,AC fa... The dynamic physical characteristics of a DC arc on an arcing horn for a high voltage direct current(HVDC)grounding electrode line are significantly different from those of the switching device arc,secondary arc,AC fault arc and pantograph-catenary arc.In this work,an experimental platform for the DC arc on the arcing horn was built,and mechanisms of the arc column short circuit and arc root movement were studied.This work further analyzes the characteristics and mechanisms of the arc motion when wind speed and direction,magnetic field and the expansion angle of the electrode are varied.Arc root movement is more likely to occur at the upper electrode.There is a competitive relationship between arc expansion and the transferring effect.The effect of wind on the arc column is greater than the effect on the arc root.The magnetic field has a significant driving effect on both the arc column and the arc root.The research results provide a comprehensive experimental basis for forther probing the method of DC arc suppression,and the improvement of the arcing horn. 展开更多
关键词 grounding electrode line arcing horn DC arc dynamic physical characteristics
下载PDF
Research on Magnetically Coupled Resonant Detection Method for Breakpoint of Four Mesh Grounding Grid
2
作者 Weihua Chen Shuai Wang +1 位作者 Xiaoheng Yan Zhiquan Ye 《CES Transactions on Electrical Machines and Systems》 CSCD 2023年第2期218-228,共11页
Magnetically coupled resonant technology is a novel method for solving the breakpoint locating of power grounding grid.But the method can only detect breakpoints of a single mesh grounding grid at present.In this pape... Magnetically coupled resonant technology is a novel method for solving the breakpoint locating of power grounding grid.But the method can only detect breakpoints of a single mesh grounding grid at present.In this paper,a magnetically coupled resonant detection method for four-hole grounding grid breakpoint is proposed.Firstly,the equivalent circuit model of the four mesh grounding grid with two types of breakpoints,namely edge branch and intermediate branch,is established.The input impedance and phase angle of the system are obtained by analyzing the equivalent capacitance and equivalent resistance in the model.Secondly,the magnetically coupled resonant physical process of grounding grid faults is solved via HFSS software.The magnetic field intensity and phase frequency characteristic curves of four mesh holes with different branches and positions of breakpoints and different corrosion degrees are studied,and an experimental system is built to verify the feasibility.The results show that under the condition of grounding grid buried depth of 0.5 m and input frequency of 1~15MHz,and there is an inverse relationship between equivalent capacitance and distortion frequency,the phase angle is positively correlated with the degree of corrosion of grounding grid,and the error of signal distortion frequency can be positioned at 5%.This paper provides some ideas for the application of magnetic coupling grounding grid detection technology. 展开更多
关键词 grounding grid Magnetically coupled resonant detection Input impedance Phase frequency characteristic curve
下载PDF
Precision grounding augments the therapeutic benefits of simultaneous topical essential oil application
3
作者 Madiha Khalid Jeremy Madvin 《TMR Non-Drug Therapy》 2023年第3期11-15,共5页
Grounding or earthing involves making physical contact with the Earth's surface by walking barefoot on natural surfaces or using grounding devices that simulate direct contact with the Earth.Precision Grounding is... Grounding or earthing involves making physical contact with the Earth's surface by walking barefoot on natural surfaces or using grounding devices that simulate direct contact with the Earth.Precision Grounding is believed to balance the electrical charge in the human body and has potential physical and psychological benefits,including reduced inflammation,improved sleep quality,and decreased anxiety and depression symptoms.Combining earthing therapy with essential oils is gaining popularity as a natural and effective therapeutic technique.Essential oils contain antioxidants and anti-inflammatory chemicals that complement the benefits of earthing therapy.This study aims to highlight a novel method for reducing inflammation by combining essential oils with precision grounding and to emphasize the significance of the duration and intensity of grounding on inflammation and injury.The findings indicate that essential oils combined with precision grounding can reduce pain and alter the levels of neutrophils,lymphocytes,and inflammation-related chemicals in circulation.The review underscores the potential of earthing with essential oils as a simple and widely available clinical intervention with potentially significant therapeutic implications.Precision Grounding therapy is safe and theoretically beneficial for most people,but medical advice should be sought before beginning any new wellness practice. 展开更多
关键词 AROMATHERAPY CAM EARTHING essential oils grounding inflammation PAIN
下载PDF
Triple One Wire System without Grounding
4
作者 Michael Bank Vladimir Tsingaouz 《Engineering(科研)》 2023年第12期867-870,共4页
Today the entire globe is shrouded in an inefficient three-phase system. There is however an efficient single-wire system. To use the single wire method, three phase systems can be converted to triple one wire systems.
关键词 Three-Phase One-Wire System ZEROING grounding Nullifier
下载PDF
Single-phase-to-ground fault protection based on zero-sequence current ratio coefficient for low-resistance grounding distribution network 被引量:4
5
作者 Jianrui Li Yongli Li +1 位作者 Yonghuan Wang Jinzhao Song 《Global Energy Interconnection》 EI CAS CSCD 2021年第6期564-575,共12页
Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to thei... Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs. 展开更多
关键词 Low-resistance grounding system High-impedance grounding fault grounding protection Zero-sequence current ratio coefficient
下载PDF
Comparative Analysis of Equal and Unequal Grounding Grid Configurations by Compression Ratio and Least Square Curve Fitting Techniques
6
作者 M.Soni Abraham George 《Energy Engineering》 EI 2023年第3期597-616,共20页
The primary aim of the power system grounding is to safeguard the person and satisfying the performance of the power systemtomaintain reliable operation.With equal conductor spacing grounding grid design,the distribut... The primary aim of the power system grounding is to safeguard the person and satisfying the performance of the power systemtomaintain reliable operation.With equal conductor spacing grounding grid design,the distribution of the current in the grid is not uniform.Hence,unequal grid conductor span in which grid conductors are concentrated more at the periphery is safer to practice than equal spacing.This paper presents the comparative analysis of two novel techniques that create unequal spacing among the grid conductors:the least-square curve fitting technique and the compression ratio techniquewith equal grid configuration for both square and rectangular grids.Particle Swarm Optimization(PSO)is adopted for finding out one optimal feasible solution among many feasible solutions of equal grid configuration for both square and rectangular grids.Comparative analysis is also carried out between square and rectangular grids using the least square curve fitting technique as it results in only one unequal grid configuration.Simulation results are obtained by theMATLAB software developed.Percentage of improvement in ground potential rise,step voltage,touch voltage,and grid resistancewith variation in compression ratios are plotted. 展开更多
关键词 Ground grid design ground potential rise grid resistance compression ratio least square curve fitting touch voltage step voltage PSO
下载PDF
Protection of Zero-Sequence Power Variation in Mountain Wind Farm Collector Lines Based on Multi-Mode Grounding
7
作者 Hongchun Shu Yaqi Deng +3 位作者 Pulin Cao Jun Dong Hongjiang Rao Zhiqian Bo 《Energy Engineering》 EI 2022年第2期523-538,共16页
The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR ground... The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR grounding wind farm.If the fault disappears before LR is put into the system,it is judged as an instantaneous fault;while the fault does not disappear after LR is put into the system,it is judged as a permanent fault;the single-phase grounding fault(SLG)protection criterion based on zerosequence power variation is proposed to identify the instantaneous-permanent fault.Firstly,the distribution characteristic of zero-sequence voltage(ZSV)and zero-sequence current(ZSC)are analyzed after SLGfault occurs in multi-mode grounding.Then,according to the characteristics that zero-sequence power variation of non-fault collector line is small,while the zero-sequence power variation of fault collector line can reflect the active power component of fault resistance,the protection criterion based on zero-sequence power variation is constructed.The theoretical analysis and simulation results show that the protection criterion can distinguish the property of fault only by using the single terminal information,which has high reliability. 展开更多
关键词 Mountain wind farm multi-mode grounding collector line single-phase grounding fault zero-sequence power variation
下载PDF
Computer Analysis of Electromagnetic Transients in Grounding Systems Considering Variation of Soil Parameters with Frequency
8
作者 Marco A.O.Schroeder Marcio M.Afonso +1 位作者 Tarcisio A.S.Oliveira Sandro C.Assis 《Journal of Electromagnetic Analysis and Applications》 2012年第12期475-480,共6页
This paper presents a mathematical model to calculate transients in grounding systems. The derived equations arise from direct application of basic electromagnetic equations in frequency domain, whose solution is obta... This paper presents a mathematical model to calculate transients in grounding systems. The derived equations arise from direct application of basic electromagnetic equations in frequency domain, whose solution is obtained by the application of the Moment Methods. A formulation based on experimental measurements is applied to quantify the soil parameters for each frequency. The unified approach is applied in the calculation of the grounding impedance of horizontal electrodes. Results show that the inclusion of frequency dependence of the soil parameters leads to a reduction of the values of grounding impedance, in comparison with results for soils with parameters independent of frequency. 展开更多
关键词 grounding Electrodes grounding Impedance Transient Response Frequency Response Electromagnetic Modeling
下载PDF
An Improved Algorithm of Grounding Grids Corrosion Diagnosis Based on Total Least Square Method 被引量:3
9
作者 ZHANG Ying-jiao NIU Tao WANG Sen 《高压电器》 CAS CSCD 北大核心 2011年第5期22-29,共8页
A new model considering corrosion property for grounding grids diagnosis is proposed,which provides reference solutions of ambiguous branches.The constraint total least square method based on singular value decomposit... A new model considering corrosion property for grounding grids diagnosis is proposed,which provides reference solutions of ambiguous branches.The constraint total least square method based on singular value decomposition is adopted to improve the effectiveness of grounding grids' diagnosis algorithm.The improvement can weaken the influence of the model's error,which results from the differences between design paper and actual grid.Its influence on touch and step voltages caused by the interior resistance of conductors is taken into account.Simulation results show the validity of this approach. 展开更多
关键词 corrosion property grounding grids corrosion diagnosis AMBIGUOUS total least square touch and step voltages
下载PDF
Determination of grounding line on the Amery Ice Shelf using Sentinel-1 radar interferometry data 被引量:2
10
作者 LEI Haobo ZHOU Chunxia CHEN Yiming 《Advances in Polar Science》 2017年第3期204-213,共10页
Delineation of the grounding line(GL) is necessary for calculating the mass balance of Antarctica, but GL measurements for most of the continent remain at a relatively coarse level. We used Sentinel-1 constellation da... Delineation of the grounding line(GL) is necessary for calculating the mass balance of Antarctica, but GL measurements for most of the continent remain at a relatively coarse level. We used Sentinel-1 constellation data to map the GL of the Amery Ice Shelf(AIS) using double-differential synthetic aperture radar interferometry. The ice thickness anomaly deduced from hydrostatic equilibrium and existing Antarctic GL products is compared with our result. With this new and very accurate GL, we detected new ice rises in the north of the AIS. Our new measurement shows no major change of the AIS GL, particularly in the southernmost part. 展开更多
关键词 grounding line DDInSAR hydrostatic equilibrium Amery Ice Shelf
下载PDF
Study on Decision Method of Neutral Point Grounding Mode for Medium-Voltage Distribution Network 被引量:2
11
作者 Hengyong Liu Xiaofu Xiong +3 位作者 Jinxin Ouyang Xiufen Gong Yinghua Xie Jing Li 《Journal of Power and Energy Engineering》 2014年第4期656-664,共9页
The neutral grounding mode of medium-voltage distribution network decides the reliability, overvoltage, relay protection and electrical safety. Therefore, a comprehensive consideration of the reliability, safety and e... The neutral grounding mode of medium-voltage distribution network decides the reliability, overvoltage, relay protection and electrical safety. Therefore, a comprehensive consideration of the reliability, safety and economy is particularly important for the decision of neutral grounding mode. This paper proposes a new decision method of neutral point grounding mode for mediumvoltage distribution network. The objective function is constructed for the decision according the life cycle cost. The reliability of the neutral point grounding mode is taken into account through treating the outage cost as an operating cost. The safety condition of the neutral point grounding mode is preserved as the constraint condition of decision models, so the decision method can generate the most economical and reliable scheme of neutral point grounding mode within a safe limit. The example is used to verify the feasibility and effectiveness of the decision method. 展开更多
关键词 Distribution Network NEUTRAL grounding MODE RELIABILITY DECISION Method Objective FUNCTION
下载PDF
Fault Line Selection Method Considering Grounding Fault Angle for Distribution Network 被引量:1
12
作者 Li Si-bo Zhao Yu-lin +1 位作者 Li Ji-chang Sui Tao 《Journal of Northeast Agricultural University(English Edition)》 CAS 2015年第1期58-65,共8页
In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line select... In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible. 展开更多
关键词 distribution network single-phase grounding fault fault line selection fault angle wavelet transformation
下载PDF
The Research on Grounding Protection for 110kV Resistance Grounding Distribution System 被引量:1
13
作者 Shan Sun Guo Zeng +2 位作者 Xiaozang He Yanping Lv Xinyi Li 《Energy and Power Engineering》 2013年第4期877-880,共4页
Using the neutral grounding method by the resistance in 110?kV system, it can limit the voltage sag and short circuit current when one-phase grounding fault occurred, but it will change the sequence of the network str... Using the neutral grounding method by the resistance in 110?kV system, it can limit the voltage sag and short circuit current when one-phase grounding fault occurred, but it will change the sequence of the network structure and parameters. This paper analyzes the size and distribution of zero sequence voltage and current when one-phase grounding fault occurred in the 110 kV resistance grounding system, and puts forward the grounding protection configuration setting principle of this system combining the power supplying characteristics of 110?kV distribution network. In a reforming substation as an example, the grounding protection of 110 kV lines and transformer have been set and calculated. 展开更多
关键词 NEUTRAL grounding System by Resistance One-phase grounding Fault ZERO SEQUENCE Voltage ZERO SEQUENCE Current PROTECTION Setting
下载PDF
An Investigation into Substation Grounding and Its Implementation on Gaza Substation 被引量:1
14
作者 Ahmed Hammuda Hassan Nouri Mohammed Saleh Al-Ayoubi 《Energy and Power Engineering》 2011年第5期593-599,共7页
An investigation into the optimal design of a substation grounding system for the transmission substation in Gaza City, Palestine has been carried out. A research into the most influential parameters on the effectiven... An investigation into the optimal design of a substation grounding system for the transmission substation in Gaza City, Palestine has been carried out. A research into the most influential parameters on the effectiveness of the substation grid system has been performed and its results have been incorporated into the Gaza case study. Through modelling and simulating the power station in Gaza while considering some field data, an optimal substation grounding grid has been designed and has shown complete conformance to safety. It is thus considered that such a design will protect personnel in any area of the substation in addition to the installed machinery if the largest possible fault current was to traverse the earth. 展开更多
关键词 GAZA grounding Grid Ground Resistance SUBSTATION STEP VOLTAGE TOUCH VOLTAGE
下载PDF
Application of Atomic Sparse Decomposition to Feature Extraction of the Fault Signal in Small Current Grounding System 被引量:1
15
作者 Nanhua Yu Rui Li +1 位作者 Jun Yang Bei Dong 《Energy and Power Engineering》 2013年第4期603-607,共5页
Applying the atomic sparse decomposition in the distribution network with harmonics and small current grounding to decompose the transient zero sequence current that appears after the single phase to ground fault occu... Applying the atomic sparse decomposition in the distribution network with harmonics and small current grounding to decompose the transient zero sequence current that appears after the single phase to ground fault occurred. Based on dictionary of Gabor atoms and matching pursuit algorithm, the method extracts the atomic components iteratively from the feature signals and translated them to damped sinusoidal components. Then we can obtain the parametrical and analytical representation of atomic components. The termination condition of decomposing iteration is determined by the threshold of the initial residual energy with the purpose of extract the features more effectively. Accordingly, the proposed method can extract the starting and ending moment of disturbances precisely as well as their magnitudes, frequencies and other features. The numerical examples demonstrate its effectiveness. 展开更多
关键词 Small Current grounding System Fault Line Selection ATOMIC SPARSE Decomposition Matching PURSUIT DAMPED SINUSOIDS
下载PDF
The Research on Neutral Grounding Scheme of Fengxian 35kV and 10 kV Power Grid 被引量:1
16
作者 Siming Hua Hua Zhang +2 位作者 Feng Qian Chunjie Chen Meixia Zhang 《Energy and Power Engineering》 2013年第4期897-901,共5页
Combined with actual situation of Fengxian power Supply Company, the neutral grounding modes of Fengxian 35 kV and 10 kV power grid are studied in the paper. The different frequencies injected method is used to measur... Combined with actual situation of Fengxian power Supply Company, the neutral grounding modes of Fengxian 35 kV and 10 kV power grid are studied in the paper. The different frequencies injected method is used to measure the capacitive current of Fengxian 28 substations, and the neutral grounding modes of the 28 substations are determined based on the measured values of capacitive current. 展开更多
关键词 NEUTRAL grounding Mode Different Frequency Injected Method Capacitive Current ARC SUPPRESSION COIL Low Resistance
下载PDF
Study on Earth Surface Potential and DC Current Distribution around DC Grounding Electrode 被引量:1
17
作者 Zhi-chao Ren Chun-yan Ye Hai-yan Wang 《Energy and Power Engineering》 2013年第4期792-796,共5页
DC magnetic biasing problem,caused by the DC grounding electrode, threatened the safe operation of AC power grid. In this paper, the characteristics of the soil stratification near DC grounding electrode was researche... DC magnetic biasing problem,caused by the DC grounding electrode, threatened the safe operation of AC power grid. In this paper, the characteristics of the soil stratification near DC grounding electrode was researched. The AC-DC interconnected large-scale system model under the monopole operation mode was established. The earth surface potential and DC current distribution in various stations under the different surface thickness was calculated. Some useful conclusions are drawn from the analyzed results. 展开更多
关键词 DC grounding ELECTRODE Magnetic BIASING Soil STRATIFICATION Earth Surface Potential DC Current DISTRIBUTION
下载PDF
Residual current compensation for single-phase grounding fault in coal mine power network 被引量:3
18
作者 Jia Chenxi Wang Chonglin Du Guifu 《International Journal of Mining Science and Technology》 SCIE EI 2014年第2期213-218,共6页
The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding curren... The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced. 展开更多
关键词 Full compensation arc suppression co Residual current compensation grounding current detection Zero sequence voltage detection
下载PDF
Small-current grounding fault location method based on transient main resonance frequency analysis 被引量:2
19
作者 Yongjie Zhang Xiaojun Wang +2 位作者 Junjuan Li Yin Xu Guohong Wu 《Global Energy Interconnection》 2020年第4期324-334,共11页
The small-current grounding fault in distribution network is hard to be located because of its weak fault features.To accurately locate the faults,the transient process is analyzed in this paper.Through the study we t... The small-current grounding fault in distribution network is hard to be located because of its weak fault features.To accurately locate the faults,the transient process is analyzed in this paper.Through the study we take that the main resonant frequency and its corresponding component is related to the fault distance.Based on this,a fault location method based on double-end wavelet energy ratio at the scale corresponding to the main resonant frequency is proposed.And back propagation neural network(BPNN)is selected to fit the non-linear relationship between the wavelet energy ratio and fault distance.The performance of this proposed method has been verified in different scenarios of a simulation model in PSCAD/EMTDC. 展开更多
关键词 Small-current grounding fault location Main resonant frequency Double-end wavelet energy ratio Backpropagation neural network(BPNN)
下载PDF
The Love Metaphor of Plant in Chinese and Its Cognitive Grounding 被引量:1
20
作者 韩涛 彭语心 《海外英语》 2021年第22期113-114,共2页
Based on the corpus,the metaphorical structure of Love Are Plants in Chinese includes six stages:(1)sowing/rooting/ger-minating,(2)growing,(3)flowering,(4)flower fading,(5)fruiting,and(6)withering.The stages of plant ... Based on the corpus,the metaphorical structure of Love Are Plants in Chinese includes six stages:(1)sowing/rooting/ger-minating,(2)growing,(3)flowering,(4)flower fading,(5)fruiting,and(6)withering.The stages of plant growth and the developmentstages of love basically show a one-to-one correspondence,and its cognitive grounding is the psychological similarity between thesource domain PLANTS and the target domain LOVE,which is not an objective existence,but a subjective judgment of the addresser. 展开更多
关键词 cognitive metaphor LOVE PLANTS grounding
下载PDF
上一页 1 2 102 下一页 到第
使用帮助 返回顶部