Intelligent substations adopt various kinds of new technologies, including information sharing technology based on IEC61850, digital sampling technology, synchronization technology, and network transmission technology...Intelligent substations adopt various kinds of new technologies, including information sharing technology based on IEC61850, digital sampling technology, synchronization technology, and network transmission technology. Relay protection equipment faces all the challenges brought by the application of these new technologies. After analyzing the demand for test, the authors propose testing methods and technical requirements targeting the test items in great need, including ICD model file test, digital interface performance test, coordination performance test with merging unit and smart terminal, network pressure test. And the problems occurring during the tests are summarized.展开更多
Accurate conditions monitoring and early wrong action warnings of relay protection in the Smart Substation is the basic guarantee to realize the normal operation of primary and secondary system of the power grid.At pr...Accurate conditions monitoring and early wrong action warnings of relay protection in the Smart Substation is the basic guarantee to realize the normal operation of primary and secondary system of the power grid.At present,the traditional operation and maintenance monitoring methods of relay protections have poor timeliness,while some automatic monitoring methods have insufficient early warning performance,and lack the online action deduction function independent of the actual device.In this paper,a design method of integrated action deduction system including protection logic reasoning and software and hardware operation condition is proposed.The system can receive real-time operation information of protection online,simulate different types of faults,and output the recording information of sub modules belongs to the action deduction system.It can realize the online monitoring of device faults such as deducing the correctness of setting values at a certain time in the future,giving the wrong action warnings and predicting the probability of them as well,which effectively improves the operation and maintenance efficiency of the secondary system in the intelligent substation.展开更多
After conducting in-depth studies on and making improvements to the operational conditions of the current transformer substation, the advanced technology of the XBZ1 intelligent transformer substation and XBJ1 pre-ins...After conducting in-depth studies on and making improvements to the operational conditions of the current transformer substation, the advanced technology of the XBZ1 intelligent transformer substation and XBJ1 pre-installed展开更多
文摘Intelligent substations adopt various kinds of new technologies, including information sharing technology based on IEC61850, digital sampling technology, synchronization technology, and network transmission technology. Relay protection equipment faces all the challenges brought by the application of these new technologies. After analyzing the demand for test, the authors propose testing methods and technical requirements targeting the test items in great need, including ICD model file test, digital interface performance test, coordination performance test with merging unit and smart terminal, network pressure test. And the problems occurring during the tests are summarized.
基金supported by the Science and Technology Program of State Grid Corporation of China(No.kj2020–056).
文摘Accurate conditions monitoring and early wrong action warnings of relay protection in the Smart Substation is the basic guarantee to realize the normal operation of primary and secondary system of the power grid.At present,the traditional operation and maintenance monitoring methods of relay protections have poor timeliness,while some automatic monitoring methods have insufficient early warning performance,and lack the online action deduction function independent of the actual device.In this paper,a design method of integrated action deduction system including protection logic reasoning and software and hardware operation condition is proposed.The system can receive real-time operation information of protection online,simulate different types of faults,and output the recording information of sub modules belongs to the action deduction system.It can realize the online monitoring of device faults such as deducing the correctness of setting values at a certain time in the future,giving the wrong action warnings and predicting the probability of them as well,which effectively improves the operation and maintenance efficiency of the secondary system in the intelligent substation.
文摘After conducting in-depth studies on and making improvements to the operational conditions of the current transformer substation, the advanced technology of the XBZ1 intelligent transformer substation and XBJ1 pre-installed