期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Determination of Curie Point Depth and Heat Flow Using Airborne Magnetic Data over the Kom-Ombo and Nuqra Basins, Southern Eastern Desert, Egypt
1
作者 Ahmed Tarshan Asmaa A. Azzazy +1 位作者 Ali M. Mostafa Ahmed A. Elhusseiny 《Geomaterials》 2023年第4期91-108,共18页
The Kom-Ombo and Nuqra basins in southern Egypt have recently been discovered as potential hydrocarbon basins. The lack of information about the geothermal gradient and heat flow in the study area gives importance to ... The Kom-Ombo and Nuqra basins in southern Egypt have recently been discovered as potential hydrocarbon basins. The lack of information about the geothermal gradient and heat flow in the study area gives importance to studying the heat flow and the geothermal gradient. Several studies were carried out to investigate the geothermal analyses of the northwestern desert, as well as the west and east of the Nile River, using density, compressive wave velocity, and bottom hole temperature (BHT) measured from deep oil wells. This research relies on spectral analysis of airborne magnetic survey data in the Kom-Ombo and Nuqra basins in order to estimate the geothermal gradient based on calculating the depth to the bottom of the magnetic source that caused the occurrence of these magnetic deviations. This depth is equal to the CPD, at which the material loses its magnetic polarisation. This method is fast and gives satisfactory results. Usually, it can be applied as a reconnaissance technique for geothermal exploration targets due to the abundance of magnetic data. The depth of the top (Z<sub>t</sub>) and centroid (Z<sub>0</sub>) of the magnetic source bodies was calculated for the 32 windows representing the study area using spectral analysis of airborne magnetic data. The curie-isotherm depth, geothermal gradient, and heat flow maps were constructed for the study area. The results showed that the CPD in the study area ranges from 13 km to 20 km. The heat flow map values range from 69 to 109 mW/m<sup>2</sup>, with an average of about 80 mW/m<sup>2</sup>. The calculated heat flow values in the assigned areas (A, B, C, and D) of the study area are considered to have high heat flow values, reaching 109 mW/m<sup>2</sup>. On the other hand, the heat flow values in the other parts range from 70 to 85 mW/m<sup>2</sup>. Since heat flow plays an essential role in the maturation of organic matter, it is recommended that hydrocarbon accumulations be located in places with high heat flow values, while deep drilling of hydrocarbon wells is recommended in places with low to moderate heat flow values. 展开更多
关键词 Curie Point Heat Flow Airborne Magnetic Data Nuqra Basin kom-ombo Basin Eastern Desert
下载PDF
Detection of the Possible Buried Archeological Targets Using the Geophysical Methods of Ground Penetrating Radar (GPR) and Self Potential (SP), Kom Ombo Temple, Aswan Governorate, Egypt
2
作者 Salem B. A. Yousef Mohamed H. M. Yousef +1 位作者 Hussein F. Abd-Elsalam Mohamed A. M. Shaheen 《Geomaterials》 2020年第4期105-117,共13页
Kom Ombo temple is one of temples which were belted over high plateau close to the River Nile, near to Aswan in Egypt in the Greek-Roman period. The expected archaeological remains in the selected area are the hidden ... Kom Ombo temple is one of temples which were belted over high plateau close to the River Nile, near to Aswan in Egypt in the Greek-Roman period. The expected archaeological remains in the selected area are the hidden tunnels of the mummified crocodiles. The aim of the present work is to detect any of these tunnels by the application of the (GPR) and (SP) methods. The interpretation of the 10 GPR profiles revealed some locations of possible hidden tunnels. These locations show different contrasts and high amplitudes of the reflected signals, compared to the enclosing soil;also the scattering of the signals is higher than the bed layer in these locations, which may reveal the possible buried mummified crocodile tunnels in the study area. The depths of the possible targets range from 2.0 m to 2.5 m. The SP electric map shows that the study area possesses a range of about 135 mV of the potential differences between the measured stations. The positive response of the SP data is mainly concentrated at the central part of the study area. The relatively weak, negative SP anomalies may be related to moisture in the soil. The positive SP anomalies on the SP electric map display possible significant correlation between them and the inferred tunnel locations from the GPR data. The calculated depths from the SP profiles show significant agreement with that estimated from GPR data depths, which indicate that the SP electric method can be used as a successful tool in detecting buried archaeological remains in support of GPR. 展开更多
关键词 Ground Penetrating Radar SELF-POTENTIAL Kom Ombo Temple Aswan EGYPT
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部