Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is...Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is a major problem in this part of the world. This non-union is a major treatment challenge with increased cost of care and morbidity in this part of the world. Humeral shaft non-union can be treated with locked intra-medullary nailing (LIMN) or dynamic compression plating (DCP). Study on comparison of these methods of fixation in this part of the world is scarce in literature search, hence the reason for this study. Objective: The objectives of this study are: (1) to compare early clinical outcome following fixation of humeral shaft fracture nonunion with DCP versus LIMN;(2) to compare the time of radiologic fracture union of DCP with LIMN;(3) to compare complications following fixation of humeral shaft fracture nonunion with DCP versus LIMN. Patients and Methods: This was a randomized control study done for 2 years in which fifty adult patients with humeral shaft non-union were recruited. The patients were grouped into 2 (P = DCP & N = LIMN). Forty five of the patients completed the follow up periods of the study and then analyzed. The P group had ORIF with DCP while the N group had ORIF with LIMN. Both groups had grafting with cancellous bones. Each patient was followed up for a period of 6 months at the time which radiographic union is expected. Any patient without clinical and/or radiographic evidence of union after six months of surgery was diagnosed as having recurrent non-union. The data generated was analyzed using SPSS Version 23. The results were presented in charts and tables. The paired t-test was used while considering p value Result: Forty five patients completed follow up. There was a male preponderance (4:1), right humerus predominated (3:2). Motor vehicular accidents were the commonest cause of the fractures (62%). Most non-union fractures occurred at the level of the middle 3<sup>rd</sup> of the humeral shaft (60%). Failed TBS treatment was the commonest indication for the osteosynthesis (71%). More patients had plating (53%) compared to 47% who had LIMN. Most patients (93.4%) had union between 3 to 6 months irrespective of fixation type with no significant statistical difference between the union rate of DCP and LIMN (p value 0.06) with similar functional outcome and complication rates irrespective of the type of fixation. Conclusion: This study showed that the success rates in term of fracture union, outcome functional grades and complication rates were not directly dependent on the types of the fixation: plating or locked intra-medullary nailing.展开更多
Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability,...Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experiment was performed in torsion, compression, and bending tests with four different screw configurations: (I) one medial-to-lateral and one oblique, (II) two me-dial-to-lateral, (III) one medial-to-lateral and one anterior-to-posterior, and (IV) one medial-to-lateral, one anterior-to-posterior and one oblique in simu-lated distal metaphyseal fracture tibiae. Twenty- four Synthes EXPERT tibial IM nails were used for six specimens of each screw configuration. Parts I and II, tibial IM nails were locked with 5.0 mm in-terlocking screws into simulated distal tibiae (PVC and composite analogue tibia). Part III, the two most stable configurations were tested using five pairs of simulated cadaveric distal tibiae metaphy-seal fractures. Results: Significant differences were attributable to distal screw orientation for intrame- dullary nailing of distal tibia fractures. Configura-tions II and IV were found to be more stable than the other two configurations. No significant differ-ence was detected in construct stability in all modes of testing between Configurations II and IV. Dis-cussion: Configuration I did not provide superior stability for the distal tibia fracture fixation. Con-figurations II and IV provided equivalent stability. When choosing IM fixation for treatment of distal tibia metaphyseal fractures two medial-to-lateral screws provide the necessary stability for satisfac-tory fixation. Clinical Relevance: This study indi-cated an option for operative treatment of distal metaphyseal tibia fracture fixation where preserva-tion of soft tissue and rigid stabilization are needed.展开更多
The distal interlocking is regarded as an inherent part of the antegrade humeral nailing technique. Traditionally the distal locking of intramedullary humeral nails is achieved using a freehand technique. The humerus ...The distal interlocking is regarded as an inherent part of the antegrade humeral nailing technique. Traditionally the distal locking of intramedullary humeral nails is achieved using a freehand technique. The humerus nailing locking options in the conventional nailing systems are placed in the anterior-posterior and lateral-medial directions. It exposes both the patient and surgeon to radiation, is time consuming, and has a potential risk of damaging neurovascular structures, especially the radial and lateral cutaneous nerve when the anterior-posterior and lateral-medial locking constructs are used. We aim to present a technical tip to ease the distal locking procedure and avoid the possible neurovascular complications with the existing nailing systems.展开更多
In proximal humeral fracture except AO classification 11A1, fixations with a locking plate and nails are recommended. We performed mechanical tests to investigate whether retrograde intramedullary nailing has fixation...In proximal humeral fracture except AO classification 11A1, fixations with a locking plate and nails are recommended. We performed mechanical tests to investigate whether retrograde intramedullary nailing has fixation stability comparable to those of anterograde intramedullary nailing and locking plate which achieve clinically favorable outcomes. In retrograde intramedullary nailing, a nail entry point is made in the diaphysis, for which reduction of stiffness of the humerus is of concern. Thus, we investigated the influence of a nail entry point made in the diaphysis on humeral strength. Retrograde intramedullary nailing had fixation stability against bending and a force loaded in the rotation direction comparable to those of anterograde intramedullary nail and locking plate. Displacement by the main external force loaded on the humerus, compressive load, was less than half in the bone fixed by retrograde intramedullary nailing compared with that in the bone fixed with a locking plate, showing favorable fixation stability. It was clarified that stiffness of the humerus against rotation and a load in the compression direction is not reduced by a nail entry point made by retrograde intramedullary nailing.展开更多
Objectives: In this study we aimed to present our treatment results of intramedullary nailing of femoral shaft fractures with compressive nailing using proximal static hole and only distal dynamic hole with one screw....Objectives: In this study we aimed to present our treatment results of intramedullary nailing of femoral shaft fractures with compressive nailing using proximal static hole and only distal dynamic hole with one screw. Methods: Forty-three patients who had a fracture of the femoral shaft were managed between 2005 and 2008 with intramedullary nailing and the use of only one screw for distal interlocking. Prospectively we evaluated the union time, possible reoperation, fixation and fracture alignment, range of knee motion and complications. Results: Union occurred within a mean duration of 18.7 weeks. No failures of the fixation and fracture alignment and no more than 1 cm shortness were detected. The knee range of motion was all more than 90 degree. Only one deep venous thrombosis was detected as complication. Conclusions: Compressive nailing using proximal hole and only distal dynamic hole with one screw is a convenient technique for femur fractures.展开更多
目的:探讨锁定钢板内固定治疗股骨近端外侧壁骨折块后的效果。方法:2021年1月至2022年6月收治31例合并外侧壁骨折的股骨转子间骨折患者,其中15例单纯采用股骨近端防旋髓内钉(proximal femoral nail antirotation,PFNA)固定,男3例,女12例...目的:探讨锁定钢板内固定治疗股骨近端外侧壁骨折块后的效果。方法:2021年1月至2022年6月收治31例合并外侧壁骨折的股骨转子间骨折患者,其中15例单纯采用股骨近端防旋髓内钉(proximal femoral nail antirotation,PFNA)固定,男3例,女12例;年龄(75.87±7.46)岁;另16例采用PFNA内固定后再应用预弯好的3.5 mm螺孔锁定钢板内固定外侧壁骨折,男4例,女12例;年龄(76.15±9.47)岁。术后随访观察记录比较两组手术指标、尖顶距(tip-apical distance,TAD)、术后负重站立时间、骨折复位情况。术后6个月根据Harris髋关节评分评价术后髋关节功能。结果:两组患者均获得随访,时间7~17(12±5)个月。两组术后即刻颈干角为111°~132°(119.3±8.3)°。骨折复位效果:PFNA组,优11例,可2例,差1例;PFNA+锁定钢板组,优12例,可3例,差1例。PFNA组1例发生螺旋刀片经股骨头切出。两组手术时间、术中出血量及手术切口长度比较,差异有统计学意义(P<0.05);两组TAD及术后负重站立时间比较,差异无统计学意义(P>0.05)。两组术后6个月Harris各项评分和总分比较,差异有统计学意义(P<0.05)。结论:应用PFNA辅助锁定钢板内固定合并外侧壁骨折的股骨转子间骨折疗效确切,可较好恢复外侧壁完整性,提高PFNA内固定的稳定性,术后并发症少。展开更多
目的比较股骨远端90°锁定钢板与弹性髓内钉治疗学龄期儿童股骨下段不稳定型骨折的疗效。方法采用随机数字表法将75例学龄期股骨下段不稳定型骨折患儿分成观察组(采用股骨远端90°锁定钢板治疗,38例)与对照组(采用闭合或切开复...目的比较股骨远端90°锁定钢板与弹性髓内钉治疗学龄期儿童股骨下段不稳定型骨折的疗效。方法采用随机数字表法将75例学龄期股骨下段不稳定型骨折患儿分成观察组(采用股骨远端90°锁定钢板治疗,38例)与对照组(采用闭合或切开复位弹性髓内钉治疗,37例)。记录手术情况、骨折复位及愈合情况、术后再移位发生率。采用HSS评分评价膝关节功能。结果患儿均获得随访,时间6~24个月。术中出血量、术中透视次数观察组均少于对照组(P<0.05)。术后3 d X线片显示两组骨折均复位良好。两组骨折愈合时间2.5~5个月。末次随访时,HSS评分优良率观察组高于对照组(P<0.05)。术后再移位发生率观察组低于对照组(P<0.05)。结论与弹性髓内钉相比,股骨远端90°锁定钢板治疗学龄期儿童股骨下段不稳定型骨折,术中出血量、透视次数更少,术后骨折再移位率更低,疗效更好。展开更多
Purpose:Long proximal femoral nail anti-rotation (PFNA-II) is a preferred implant in recent years for fixation of pertrochanteric fractures,especially in osteoporotic patients.The purpose of this study is to prospecti...Purpose:Long proximal femoral nail anti-rotation (PFNA-II) is a preferred implant in recent years for fixation of pertrochanteric fractures,especially in osteoporotic patients.The purpose of this study is to prospectively investigate the effect of distal locking in long PFNA-II fixation of stable intertrochanteric fractures.Methods:A total of 58 patients with isolated stable intertrochanteric fractures and treated in our hospital during the study period of 2017–2019 by distal locked or unlocked long PFNA-II fixation were included in this study.Patients who had multiple injuries or open fractures were excluded.There were 40 female and 18 male patients,with 33 affecting the left side and 25 the right side.Of them,31 belonged to the distal locked group (group A) and 27 to the unlocked group (group B).Surgical procedures and implants used in both groups were similar except for the distal locking of the nails.General data (age,gender,fracture side,etc.) showed no significant difference between two groups (allp > 0.05).The intraoperative parameters like operative time,radiation exposure and follow-up parameters like functional and radiological outcomes were recorded and compared.Statistical tests like the independent samplest-test Fischer’’s exact and Chi-square test were used to analyze association.Results:The distribution of the fractures according to AO/OTA classification and 31A1.2 type of intertrochanteric fractures were most common in our study.All the included fractures united and the average functional outcome in both groups were good and comparable at the end of one year.The operative time (mL,107.1 ± 12.6vs.77.0 ± 12.0,p < 0.001) and radiation exposure (s,78.6 ± 11.0vs.40.3 ± 9.3,p < 0.001) were significantly less among the patients in group B.Fracture consolidation,three months after the operative procedures,was seen in a significantly greater proportion of patients in group B (92.6%vs.67.7%,p = 0.025).Hardware irritation because of distal locking bolt was exclusively seen in group A,however this was not statistically significant (p = 0.241).Conclusion:We conclude that,in fixation of stable intertrochanteric fractures by long PFNA-II nail,distal locking not only increases the operative time and radiation exposure but also delays the fracture consolidation and increases the chances of hardware irritation,and hence is not required.展开更多
文摘Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is a major problem in this part of the world. This non-union is a major treatment challenge with increased cost of care and morbidity in this part of the world. Humeral shaft non-union can be treated with locked intra-medullary nailing (LIMN) or dynamic compression plating (DCP). Study on comparison of these methods of fixation in this part of the world is scarce in literature search, hence the reason for this study. Objective: The objectives of this study are: (1) to compare early clinical outcome following fixation of humeral shaft fracture nonunion with DCP versus LIMN;(2) to compare the time of radiologic fracture union of DCP with LIMN;(3) to compare complications following fixation of humeral shaft fracture nonunion with DCP versus LIMN. Patients and Methods: This was a randomized control study done for 2 years in which fifty adult patients with humeral shaft non-union were recruited. The patients were grouped into 2 (P = DCP & N = LIMN). Forty five of the patients completed the follow up periods of the study and then analyzed. The P group had ORIF with DCP while the N group had ORIF with LIMN. Both groups had grafting with cancellous bones. Each patient was followed up for a period of 6 months at the time which radiographic union is expected. Any patient without clinical and/or radiographic evidence of union after six months of surgery was diagnosed as having recurrent non-union. The data generated was analyzed using SPSS Version 23. The results were presented in charts and tables. The paired t-test was used while considering p value Result: Forty five patients completed follow up. There was a male preponderance (4:1), right humerus predominated (3:2). Motor vehicular accidents were the commonest cause of the fractures (62%). Most non-union fractures occurred at the level of the middle 3<sup>rd</sup> of the humeral shaft (60%). Failed TBS treatment was the commonest indication for the osteosynthesis (71%). More patients had plating (53%) compared to 47% who had LIMN. Most patients (93.4%) had union between 3 to 6 months irrespective of fixation type with no significant statistical difference between the union rate of DCP and LIMN (p value 0.06) with similar functional outcome and complication rates irrespective of the type of fixation. Conclusion: This study showed that the success rates in term of fracture union, outcome functional grades and complication rates were not directly dependent on the types of the fixation: plating or locked intra-medullary nailing.
文摘Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experiment was performed in torsion, compression, and bending tests with four different screw configurations: (I) one medial-to-lateral and one oblique, (II) two me-dial-to-lateral, (III) one medial-to-lateral and one anterior-to-posterior, and (IV) one medial-to-lateral, one anterior-to-posterior and one oblique in simu-lated distal metaphyseal fracture tibiae. Twenty- four Synthes EXPERT tibial IM nails were used for six specimens of each screw configuration. Parts I and II, tibial IM nails were locked with 5.0 mm in-terlocking screws into simulated distal tibiae (PVC and composite analogue tibia). Part III, the two most stable configurations were tested using five pairs of simulated cadaveric distal tibiae metaphy-seal fractures. Results: Significant differences were attributable to distal screw orientation for intrame- dullary nailing of distal tibia fractures. Configura-tions II and IV were found to be more stable than the other two configurations. No significant differ-ence was detected in construct stability in all modes of testing between Configurations II and IV. Dis-cussion: Configuration I did not provide superior stability for the distal tibia fracture fixation. Con-figurations II and IV provided equivalent stability. When choosing IM fixation for treatment of distal tibia metaphyseal fractures two medial-to-lateral screws provide the necessary stability for satisfac-tory fixation. Clinical Relevance: This study indi-cated an option for operative treatment of distal metaphyseal tibia fracture fixation where preserva-tion of soft tissue and rigid stabilization are needed.
文摘The distal interlocking is regarded as an inherent part of the antegrade humeral nailing technique. Traditionally the distal locking of intramedullary humeral nails is achieved using a freehand technique. The humerus nailing locking options in the conventional nailing systems are placed in the anterior-posterior and lateral-medial directions. It exposes both the patient and surgeon to radiation, is time consuming, and has a potential risk of damaging neurovascular structures, especially the radial and lateral cutaneous nerve when the anterior-posterior and lateral-medial locking constructs are used. We aim to present a technical tip to ease the distal locking procedure and avoid the possible neurovascular complications with the existing nailing systems.
文摘In proximal humeral fracture except AO classification 11A1, fixations with a locking plate and nails are recommended. We performed mechanical tests to investigate whether retrograde intramedullary nailing has fixation stability comparable to those of anterograde intramedullary nailing and locking plate which achieve clinically favorable outcomes. In retrograde intramedullary nailing, a nail entry point is made in the diaphysis, for which reduction of stiffness of the humerus is of concern. Thus, we investigated the influence of a nail entry point made in the diaphysis on humeral strength. Retrograde intramedullary nailing had fixation stability against bending and a force loaded in the rotation direction comparable to those of anterograde intramedullary nail and locking plate. Displacement by the main external force loaded on the humerus, compressive load, was less than half in the bone fixed by retrograde intramedullary nailing compared with that in the bone fixed with a locking plate, showing favorable fixation stability. It was clarified that stiffness of the humerus against rotation and a load in the compression direction is not reduced by a nail entry point made by retrograde intramedullary nailing.
文摘Objectives: In this study we aimed to present our treatment results of intramedullary nailing of femoral shaft fractures with compressive nailing using proximal static hole and only distal dynamic hole with one screw. Methods: Forty-three patients who had a fracture of the femoral shaft were managed between 2005 and 2008 with intramedullary nailing and the use of only one screw for distal interlocking. Prospectively we evaluated the union time, possible reoperation, fixation and fracture alignment, range of knee motion and complications. Results: Union occurred within a mean duration of 18.7 weeks. No failures of the fixation and fracture alignment and no more than 1 cm shortness were detected. The knee range of motion was all more than 90 degree. Only one deep venous thrombosis was detected as complication. Conclusions: Compressive nailing using proximal hole and only distal dynamic hole with one screw is a convenient technique for femur fractures.
文摘目的比较股骨远端90°锁定钢板与弹性髓内钉治疗学龄期儿童股骨下段不稳定型骨折的疗效。方法采用随机数字表法将75例学龄期股骨下段不稳定型骨折患儿分成观察组(采用股骨远端90°锁定钢板治疗,38例)与对照组(采用闭合或切开复位弹性髓内钉治疗,37例)。记录手术情况、骨折复位及愈合情况、术后再移位发生率。采用HSS评分评价膝关节功能。结果患儿均获得随访,时间6~24个月。术中出血量、术中透视次数观察组均少于对照组(P<0.05)。术后3 d X线片显示两组骨折均复位良好。两组骨折愈合时间2.5~5个月。末次随访时,HSS评分优良率观察组高于对照组(P<0.05)。术后再移位发生率观察组低于对照组(P<0.05)。结论与弹性髓内钉相比,股骨远端90°锁定钢板治疗学龄期儿童股骨下段不稳定型骨折,术中出血量、透视次数更少,术后骨折再移位率更低,疗效更好。
文摘Purpose:Long proximal femoral nail anti-rotation (PFNA-II) is a preferred implant in recent years for fixation of pertrochanteric fractures,especially in osteoporotic patients.The purpose of this study is to prospectively investigate the effect of distal locking in long PFNA-II fixation of stable intertrochanteric fractures.Methods:A total of 58 patients with isolated stable intertrochanteric fractures and treated in our hospital during the study period of 2017–2019 by distal locked or unlocked long PFNA-II fixation were included in this study.Patients who had multiple injuries or open fractures were excluded.There were 40 female and 18 male patients,with 33 affecting the left side and 25 the right side.Of them,31 belonged to the distal locked group (group A) and 27 to the unlocked group (group B).Surgical procedures and implants used in both groups were similar except for the distal locking of the nails.General data (age,gender,fracture side,etc.) showed no significant difference between two groups (allp > 0.05).The intraoperative parameters like operative time,radiation exposure and follow-up parameters like functional and radiological outcomes were recorded and compared.Statistical tests like the independent samplest-test Fischer’’s exact and Chi-square test were used to analyze association.Results:The distribution of the fractures according to AO/OTA classification and 31A1.2 type of intertrochanteric fractures were most common in our study.All the included fractures united and the average functional outcome in both groups were good and comparable at the end of one year.The operative time (mL,107.1 ± 12.6vs.77.0 ± 12.0,p < 0.001) and radiation exposure (s,78.6 ± 11.0vs.40.3 ± 9.3,p < 0.001) were significantly less among the patients in group B.Fracture consolidation,three months after the operative procedures,was seen in a significantly greater proportion of patients in group B (92.6%vs.67.7%,p = 0.025).Hardware irritation because of distal locking bolt was exclusively seen in group A,however this was not statistically significant (p = 0.241).Conclusion:We conclude that,in fixation of stable intertrochanteric fractures by long PFNA-II nail,distal locking not only increases the operative time and radiation exposure but also delays the fracture consolidation and increases the chances of hardware irritation,and hence is not required.