Endoscopic-ultrasound-guided biliary drainage with placement of electrocautery-enhanced lumen-apposing metal stent for palliation of malignant biliary obstruction:Updated meta-analysis 被引量:7
1
作者 Zu-Xiang Peng Fang-Fang Chen +5 位作者 Wen Tang Xu Zeng Hong-Juan Du Ru-Xian Pi Hong-Ming Liu Xiao-Xiao Lu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第3期907-920,共14页
BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant bili... BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant biliary obstruction after endoscopic retrograde cholangiopancreatography(ERCP)failure.However,most of the studies that have assessed its efficacy and safety were small and hetero-geneous.Prior meta-analyses of six or fewer studies that were published 2 years ago were therefore underpowered to yield convincing evidence.AIM To update the efficacy and safety of ECE-LAMS for treatment of biliary ob-struction after ERCP failure.METHODS We searched PubMed,EMBASE,and Scopus databases from the inception of the ECE technique to May 13,2022.Primary outcome measure was pooled technical success rate,and secondary outcomes were pooled rates of clinical success,re-intervention,and adverse events.Meta-analysis was performed using a random-effects model following Freeman-Tukey double-arcsine transformation in R soft-ware(version 4.1.3).RESULTS Fourteen eligible studies involving 620 participants were ultimately included.The pooled rate of technical success was 96.7%,and clinical success was 91.0%.Adverse events were reported in 17.5%of patients.Overall reinter-vention rate was 7.3%.Subgroup analyses showed results were generally consistent.CONCLUSION ECE-LAMS has favorable success with acceptable adverse events in relieving biliary obstruction when ERCP is impossible.The consistency of results across most subgroups suggested that this is a generalizable approach. 展开更多
关键词 Biliary obstruction Biliary drainage Electrocautery-enhanced lumen-apposing metal stents Endoscopic ultrasound Endoscopic retrograde cholangiopancreatography failure
下载PDF
Endoscopic ultrasound-guided biliary drainage using electrocauteryenhanced lumen-apposing metal stent for malignant biliary obstruction:A promising procedure
2
作者 Si-Ze Wu 《World Journal of Clinical Cases》 SCIE 2024年第26期5859-5862,共4页
In this editorial,we comment on the article by Peng et al.Palliative drainage for biliary obstruction resulting from unresectable malignant lesions includes internal and external drainage.The procedures of biliary dra... In this editorial,we comment on the article by Peng et al.Palliative drainage for biliary obstruction resulting from unresectable malignant lesions includes internal and external drainage.The procedures of biliary drainage are usually guided by fluoroscopy or transcutaneous ultrasound,endoscopic ultrasound(EUS),or both.Endoscopic retrograde cholangiopancreatography(ERCP)has been primarily recommended for the management of biliary obstruction,while EUS-guided biliary drainage and percutaneous transhepatic biliary drainage(PTBD)are alternative choices for cases where ERCP has failed or is impossible.PTBD is limited by shortcomings of a higher rate of adverse events,more reinterventions,and severe complications.EUS-guided biliary drainage has a lower rate of adverse events than PTBD.EUS-guided biliary drainage with electrocautery-enhanced lumen-apposing metal stent(ECE-LAMS)enables EUS-guided biliaryenteric anastomosis to be performed in a single step and does not require prior bile duct puncture or a guidewire.The present meta-analysis showed that ECELAMS has a high efficacy and safety in relieving biliary obstruction in general,although the results of LAMS depending on the site of biliary obstruction.This study has highlighted the latest advances with a larger sample-based comprehensive analysis. 展开更多
关键词 Malignant biliary obstruction Biliary drainage Percutaneous transhepatic biliary drainage Electrocautery-enhanced lumen-apposing metal stents Transcutaneous ultrasound Endoscopic ultrasound Endoscopic retrograde cholangiopancreatography
下载PDF
Unveiling the potential of electrocautery-enhanced lumen-apposing metal stents in endoscopic ultrasound-guided biliary drainage
3
作者 Meer M Chisthi 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第7期1956-1959,共4页
This editorial delves into Peng et al's article,published in the World Journal of Gastrointestinal Surgery.Peng et al's meta-analysis investigates the effectiveness of electrocautery-enhanced lumen-apposing me... This editorial delves into Peng et al's article,published in the World Journal of Gastrointestinal Surgery.Peng et al's meta-analysis investigates the effectiveness of electrocautery-enhanced lumen-apposing metal stents(ECE-LAMS)in ultrasound-guided biliary drainage for alleviating malignant biliary obstruction.Examining 14 studies encompassing 620 participants,the research underscores a robust technical success rate of 96.7%,highlighting the efficacy of ECE-LAMS,particularly in challenging cases which have failed endoscopic retrograde cholangio pancreatography.A clinical success rate of 91.0% underscores its impact on symptom alleviation,while a reasonably tolerable adverse event rate of 17.5% is observed.However,the 7.3% re-intervention rate stresses the need for post-procedural monitoring.Subgroup analyses validate consistent outcomes,bolstering the applicability of ECE-LAMS.These findings advocate for the adoption of ECELAMS as an appropriate approach for biliary palliation,urging further exploration in real-world clinical contexts.They offer valuable insights for optimizing interventions targeting malignant biliary obstruction management. 展开更多
关键词 Biliary drainage Electrocautery-enhanced lumen-apposing metal stent Endoscopic retrograde cholangiopancreatography Endoscopic ultrasound Malignant biliary obstruction
下载PDF
Role of endoscopic-ultrasound-guided biliary drainage with electrocautery-enhanced lumen-apposing metal stent for palliation of malignant biliary obstruction
4
作者 Smit S Deliwala Emad Qayed 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第7期1981-1985,共5页
In this editorial,we discuss the article by Peng et al in the recent issue of the World Journal of Gastrointestinal Surgery,focusing on the evolving role of endoscopicultrasound-guided biliary drainage(EUS-BD)with ele... In this editorial,we discuss the article by Peng et al in the recent issue of the World Journal of Gastrointestinal Surgery,focusing on the evolving role of endoscopicultrasound-guided biliary drainage(EUS-BD)with electrocautery lumen apposing metal stent(LAMS)for distal malignant biliary obstruction.Therapeutic endoscopy has rapidly advanced in decompression techniques,with growing evidence of its safety and efficacy surpassing percutaneous and surgical approaches.While endoscopic retrograde cholangiopancreatography(ERCP)has been the gold standard for biliary decompression,its failure rate approaches 10.0%,prompting the exploration of alternatives like EUS-BD.This random-effects meta-analysis demonstrated high technical and clinical success of over 90.0% and an adverse event rate of 17.5%,mainly in the form of stent dysfunction.Outcomes based on stent size were not reported but the majority used 6 mm and 8 mm stents.As the body of literature continues to demonstrate the effectiveness of this technique,the challenges of stent dysfunction need to be addressed in future studies.One strategy that has shown promise is placement of double-pigtail stents,only 18% received the prophylactic intervention in this study.We expect this to improve with time as the technique continues to be refined and standardized.The results above establish EUS-BD with LAMS as a reliable alternative after failed ERCP and considering EUS to ERCP upfront in the same session is an effective strategy.Given the promising results,studies must explore the role of EUS-BD as first-line therapy for biliary decompression. 展开更多
关键词 Endoscopic-ultrasound Malignant biliary obstruction Lumen apposing metal stent CHOLEDOCHODUODENOSTOMY Hepaticogastrostomy
下载PDF
Lumen-apposing metal stents for malignant biliary obstruction: Is this the ultimate horizon of our experience? 被引量:7
5
作者 Andrea Anderloni Edoardo Troncone +4 位作者 Alessandro Fugazza Annalisa Cappello Giovanna Del Vecchio Blanco Giovanni Monteleone Alessandro Repici 《World Journal of Gastroenterology》 SCIE CAS 2019年第29期3857-3869,共13页
In the last years, endoscopic ultrasonography (EUS) has evolved from a purely diagnostic technique to a more and more complex interventional procedure, with the possibility to perform several type of therapeutic inter... In the last years, endoscopic ultrasonography (EUS) has evolved from a purely diagnostic technique to a more and more complex interventional procedure, with the possibility to perform several type of therapeutic interventions. Among these, EUS-guided biliary drainage (BD) is gaining popularity as a therapeutic approach after failed endoscopic retrograde cholangiopancreatography in distal malignant biliary obstruction (MBO), due to the avoidance of external drainage, a lower rate of adverse events and re-interventions, and lower costs compared to percutaneous trans-hepatic BD. Initially, devices created for luminal procedures (e.g., luminal biliary stents) have been adapted to the new trans-luminal EUSguided interventions, with predictable shortcomings in technical success, outcome and adverse events. More recently, new metal stents specifically designed for transluminal drainage, namely lumen-apposing metal stents (LAMS), have been made available for EUS-guided procedures. An electrocautery enhanced delivery system (EC-LAMS), which allows direct access of the delivery system to the target lumen, has subsequently simplified the classic multi-step procedure of EUS-guided drainages. EUS-BD using LAMS and ECLAMS has been demonstrated effective and safe, and currently seems one of the most performing techniques for EUS-BD. In this Review, we summarize the evolution of the EUS-BD in distal MBO, focusing on the novelty of LAMS and analyzing the unresolved questions about the possible role of EUS as the first therapeutic option to achieve BD in this setting of patients. 展开更多
关键词 Interventional ENDOSCOPIC ULTRASONOGRAPHY ENDOSCOPIC ultrasonography-guided BILIARY drainage ENDOSCOPIC ultrasonography-guided choledocho-duodenostomy BILIARY metal stent lumen-apposing metal stent
下载PDF
Off label use of lumen-apposing metal stent for persistent gastro-jejunal anastomotic stricture
6
作者 Muhammad Sohail Mansoor Juan Tejada +2 位作者 Nour A Parsa Eric Yoon Sven Hida 《World Journal of Gastrointestinal Endoscopy》 CAS 2018年第6期117-120,共4页
We are reporting a novel "off-label" use of lumen apposing metal stent(LAMS) for management of refractory gastro-jejunal(GJ) anastomotic stricture after Roux-en-y gastric bypass(RYGB). With increasing preval... We are reporting a novel "off-label" use of lumen apposing metal stent(LAMS) for management of refractory gastro-jejunal(GJ) anastomotic stricture after Roux-en-y gastric bypass(RYGB). With increasing prevalence of obesity, bariatric surgery is performed more frequently than ever. RYGB is one of the most commonly performed bariatric procedures. GJ anastomotic stricture is a late complication of this procedure. Our patient, seven years after RYGB developed GJ anastomotic ulcer and subsequently a stricture not amendable to repeated pneumatic dilations. Instead of using the conventional fully covered self-expanding metal stent(fc SEMS) we deployed the relatively new LAMS keeping in mind its novel dumbbell shaped design. Our patient's symptoms were controlled successfully and she remained asymptomatic on follow-up. Despite initial approval for pancreatic pseudocyst drainage, LAMS has been used with increased frequency at various locations within gastrointestinal tract including GJ anastomotic strictures. Future randomized control trials are warranted to compare the efficacy of fcSEMS to LAMS. 展开更多
关键词 Gastro-jejunal anastomotic STRICTURE LUMEN apposing metal stent DYSPHAGIA ROUX-EN-Y gastric BYPASS
下载PDF
Lumen-apposing-metal stent misdeployment in endoscopic ultrasound-guided drainages:A systematic review focusing on issues and rescue management 被引量:1
7
作者 Elia Armellini Flavio Metelli +4 位作者 Andrea Anderloni Anna Cominardi Giovanni Aragona Michele Marini FabioPace 《World Journal of Gastroenterology》 SCIE CAS 2023年第21期3341-3361,共21页
BACKGROUND The introduction of lumen-apposing metal stents(LAMS)for endoscopic ultrasound(EUS)-guided drainages has marked a turning point in the field of interventional ultrasound and it is gathering worldwide diffus... BACKGROUND The introduction of lumen-apposing metal stents(LAMS)for endoscopic ultrasound(EUS)-guided drainages has marked a turning point in the field of interventional ultrasound and it is gathering worldwide diffusion in different clinical settings.Nevertheless,the procedure may conceal unexpected pitfalls.LAMS misdeployment is the most frequent cause of technical failure and it can be considered a procedure-related adverse event when it hampers the conclusion of the planned procedure or results in significant clinical consequences.Stent misdeployment can be managed successfully by endoscopic rescue maneuvers to allow the completion of the procedure.To date,no standardized indication is available to guide an appropriate rescue strategy depending on the type of procedure or of misdeployment.AIM To evaluate the incidence of LAMS misdeployment during EUS-guided choledochoduodenostomy(EUS-CDS),gallbladder drainage(EUS-GBD)and pancreatic fluid collections drainage(EUS-PFC)and to describe the endoscopic rescue strategies adopted under the circumstance.METHODS We conducted a systematic review of the literature on PubMed by searching for studies published up to October 2022.The search was carried out using the exploded medical subject heading terms“lumen apposing metal stent”,“LAMS”,“endoscopic ultrasound”and“choledochoduodenostomy”or“gallbladder”or“pancreatic fluid collections”.We included in the review on-label EUS-guided procedures namely EUS-CDS,EUS-GBD and EUS-PFC.Only those publications reporting EUS-guided LAMS positioning were considered.The studies reporting a technical success rate of 100%and other procedure-related adverse events were considered to calculate the overall rate of LAMS misdeployment,while studies not reporting the causes of technical failure were excluded.Case reports were considered only for the extraction of data regarding the issues of misdeployment and rescue techniques.The following data were collected from each study:Author,year of publication,study design,study population,clinical indication,technical success,reported number of misdeployment,stent type and size,flange misdeployed and type of rescue strategy.RESULTS The overall technical success rate of EUS-CDS,EUS-GBD and EUS-PFC was 93.7%,96.1%,and 98.1%respectively.Significant rates of LAMS misdeployment have been reported for EUS-CDS,EUS-GBD and EUS-PFC drainage,respectively 5.8%,3.4%,and 2.0%.Endoscopic rescue treatment was feasible in 86.8%,80%,and 96.8%of cases.Non endoscopic rescue strategies were required only in 10.3%,16%and 3.2%for EUS-CDS,EUS-GBD,and EUS-PFC.The endoscopic rescue techniques described were over-the-wire deployment of a new stent through the created fistula tract in 44.1%,8%and 64.5%and stent-in-stent in 23.5%,60%,and 12.9%,respectively for EUSCDS,EUS-GBD,and EUS-PFC.Further therapeutic option were endoscopic rendezvous in 11.8%of EUS-CDS and repeated procedure of EUS-guided drainage in 16.1%of EUS-PFC.CONCLUSION LAMS misdeployment is a relatively common adverse event in EUS-guided drainages.There is no consensus on the best rescue approach in these cases and the choice is often made by the endoscopist relying upon the clinical scenario,anatomical characteristics,and local expertise.In this review,we investigated the misdeployment of LAMS for each of the on-label indications focusing on the rescue therapies used,with the aim of providing useful data for endoscopists and to improve patient outcomes. 展开更多
关键词 Lams misdeployment Endoscopic ultrasound-guided drainage Lams maldeployment Biliary drainage Gallbladder drainage Pancreatic fluid collections lumen-apposing metal stents
下载PDF
Defining failure of endoluminal biliary drainage in the era of endoscopic ultrasound and lumen apposing metal stents
8
作者 Faisal S Ali Sushovan Guha 《World Journal of Gastroenterology》 SCIE CAS 2024年第29期3534-3537,共4页
The role of endoscopy in pathologies of the bile duct and gallbladder has seen notable advancements over the past two decades.With advancements in stent technology,such as the development of lumen-apposing metal stent... The role of endoscopy in pathologies of the bile duct and gallbladder has seen notable advancements over the past two decades.With advancements in stent technology,such as the development of lumen-apposing metal stents,and adoption of endoscopic ultrasound and electrosurgical principles in therapeutic endoscopy,what was once considered endoscopic failure has transformed into failure of an approach that could be salvaged by a second-or third-line endoscopic strategy.Incorporation of these advancements in routine patient care will require formal training and multidisciplinary acceptance of established techniques and collaboration for advancement of experimental techniques to generate robust evidence that can be utilized to serve patients to the best of our ability. 展开更多
关键词 Endoscopic ultrasound Guided biliary drainage GALLBLADDER Biliary obstruction lumen-apposing metal stent
下载PDF
Revolutionizing palliative care:Electrocautery-enhanced lumenapposing metal stents in endoscopic-ultrasound-guided biliary drainage for malignant obstructions
9
作者 Nirmal Kumar Reddy Onteddu Naga Sai Rasagna Mareddy +2 位作者 Sai Swarupa R Vulasala Jayabharath Onteddu Mayur Virarkar 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第7期2358-2361,共4页
Patients with malignant biliary obstruction,following endoscopic retrograde cholangiopancreatography(ERCP)failure could be referred for endoscopicultrasound-guided biliary drainage through electrocautery-enhanced(ECE)... Patients with malignant biliary obstruction,following endoscopic retrograde cholangiopancreatography(ERCP)failure could be referred for endoscopicultrasound-guided biliary drainage through electrocautery-enhanced(ECE)lumen-apposing metal stent(LAMS)placement.However,the efficacy and safety of ECE-LAMS in this scenario have remained debatable due to minimal scientific evidence.The current confirmed 91.0%clinical success,96.7%technical success,7.3%reintervention rate,and 17.5%adverse events,following the treatment of malignant biliary obstruction with ECE-LAMS delivery.Finally,ECE-LAMS proved to be a generalizable strategy for managing biliary obstruction for patients who were excluded from ERCP. 展开更多
关键词 Endoscopic retrograde cholangiopancreatography Electrocautery-enhancedlumen-apposing metal stent Biliary drainage Biliary stent Endoscopic ultrasound
下载PDF
Safety and efficacy of Kaffes intraductal self-expanding metal stents in the management of post-liver transplant anastomotic strictures
10
作者 Chee Lim Jonathan Ng +4 位作者 Babak Sarraf Rhys Vaughan Marios Efthymiou Leonardo Zorron Cheng Tao Pu Sujievvan Chandran 《World Journal of Transplantation》 2024年第2期88-98,共11页
BACKGROUND Endoscopic management is the first-line therapy for post-liver-transplant anas-tomotic strictures.Although the optimal duration of treatment with plastic stents has been reported to be 8-12 months,data on s... BACKGROUND Endoscopic management is the first-line therapy for post-liver-transplant anas-tomotic strictures.Although the optimal duration of treatment with plastic stents has been reported to be 8-12 months,data on safety and duration for metal stents in this setting is scarce.Due to limited access to endoscopic retrograde cholan-giopancreatography(ERCP)during the coronavirus disease 2019 pandemic in our centre,there was a change in practice towards increased usage and length-of-stay of the Kaffes biliary intraductal self-expanding stent in patients with suitable anatomy.This was mainly due to the theoretical benefit of Kaffes stents allowing for longer indwelling periods compared to the traditional plastic stents.METHODS Adult liver transplant recipients aged 18 years and above who underwent ERCP were retrospectively identified during a 10-year period through a database query.Unplanned admissions post-Kaffes stent insertion were identified manually through electronic and scanned medical records.The main outcome was the incidence of complications when stents were left indwelling for 3 months vs 6 months.Stent efficacy was calculated via rates of stricture recurrence between patients that had stenting courses for≤120 d or>120 d.RESULTS During the study period,a total of 66 ERCPs with Kaffes insertion were performed in 54 patients throughout their stenting course.In 33 ERCPs,the stent was removed or exchanged on a 3-month interval.No pancreatitis,perfor-ations or deaths occurred.Minor post-ERCP complications were similar between the 3-month(abdominal pain and intraductal migration)and 6-month(abdominal pain,septic shower and embedded stent)groups-6.1%vs 9.1%respectively,P=0.40.All strictures resolved at the end of the stenting course,but the stenting course was variable from 3 to 22 months.The recurrence rate for stenting courses lasting for up to 120 d was 71.4%and 21.4%for stenting courses of 121 d or over(P=0.03).There were 28 patients that were treated with a single ERCP with Kaffes,21 with removal after 120 d and 7 within 120 d.There was a significant improvement in stricture recurrence when the Kaffes was removed after 120 d when a single ERCP was used for the entire stenting course(71.0%vs 10.0%,P=0.01).CONCLUSION Utilising a single Kaffes intraductal fully-covered metal stent for at least 4 months is safe and efficacious for the management of post-transplant anastomotic strictures. 展开更多
关键词 Liver transplantation CHOLANGIOPANCREATOGRAPHY Endoscopic retrograde CONSTRICTION PATHOLOGIC Self expandable metallic stents Bile duct diseases CHOLESTASIS
下载PDF
Short benign ileocolonic anastomotic strictures-management with bi-flanged metal stents:Six case reports and review of literature
11
作者 Panagiotis Kasapidis Georgios Mavrogenis +1 位作者 Dimitrios Mandrekas Fateh Bazerbachi 《World Journal of Clinical Cases》 SCIE 2022年第28期10162-10171,共10页
BACKGROUND The endoscopic management of benign short post-anastomotic ileocolonic stricture(PAICS) that is refractory to primary and secondary treatment modalities remains challenging.The lumen-apposing metal stent(LA... BACKGROUND The endoscopic management of benign short post-anastomotic ileocolonic stricture(PAICS) that is refractory to primary and secondary treatment modalities remains challenging.The lumen-apposing metal stent(LAMS) is a novel device recently developed for therapeutic gastrointestinal endoscopy.LAMSs have demonstrated significantly better results with regard to stent migration than fully covered self-expandable metal stents(FCSEMSs).CASE SUMMARY This article presents six cases of symptomatic PAICS successfully treated with a LAMS and a review of the relevant literature.We report a life-saving technique not previously documented and the use of technology to improve patient outcomes.The six patients(median age,75 years) suffered from vomiting,constipation and recurrent abdominal pain,with symptoms starting 23-25 wk post-surgery.The median stricture length was 1.83 cm.All six patients underwent successful and uneventful bi-flanged metal stent(BFMS)-LAMS placement for benign PAICS.All patients remained asymptomatic during the three months of stent indwelling and up to a median of 7 mo after stent removal.According to the literature,the application of LAMS for PAICS is associated with a < 10% risk of migration and a < 5% risk of bleeding.Conversely,FCSEMS has a high migration rate(15%-50%).CONCLUSION The evolving role of interventional endoscopy and the availability of LAMSs provide patients with minimally invasive treatment options,allowing them to avoid more invasive surgical interventions.The BFMS(NAGI stent) is longer and larger than the prototype AXIOS-LAMS,which should be considered in the management of short ileocolonic post-anastomotic strictures longer than 10 mm and shorter than 30 mm. 展开更多
关键词 Bi-flanged metal stent lumen-apposing metal stent Anastomotic ileocolonic stricture Selfexpanding metal stent Endoscopic innovation Case report
下载PDF
Self-expandable metallic stent placement plus laparoscopy for acute malignant colorectal obstruction 被引量:12
12
作者 Jia-Min Zhou Li-Qing Yao +7 位作者 Jian-Min Xu Mei-Dong Xu Ping-Hong Zhou Wei-Feng Chen Qiang Shi Zhong Ren Tao Chen Yun-Shi Zhong 《World Journal of Gastroenterology》 SCIE CAS 2013年第33期5513-5519,共7页
AIM:To investigate the clinical advantages of the stent-laparoscopy approach to treat colorectal cancer(CRC)patients with acute colorectal obstruction(ACO).METHODS:From April 2008 to April 2012,surgeryrelated paramete... AIM:To investigate the clinical advantages of the stent-laparoscopy approach to treat colorectal cancer(CRC)patients with acute colorectal obstruction(ACO).METHODS:From April 2008 to April 2012,surgeryrelated parameters,complications,overall survival(OS),and disease-free survival(DFS)of 74 consecutive patients with left-sided CRC presented with ACO who underwent self-expandable metallic stent(SEMS)placement followed by one-stage open(n=58)or laparoscopic resection(n=16)were evaluated retrospectively.The stent-laparoscopy group was also compared with a control group of 96 CRC patients who underwent regular laparoscopy without ACO between January 2010 and December 2011 to explore whether SEMS placement influenced the laparoscopic procedure or reduced long-term survival by influencing CRC oncological characteristics.RESULTS:The characteristics of patients among these groups were comparable.The rate of conversion to open surgery was 12.5%in the stent-laparoscopy group.Bowel function recovery and postoperative hospital stay were significantly shorter(3.3±0.9 d vs 4.2±1.5 d and 6.7±1.1 d vs 9.5±6.7 d,P=0.016 and P=0.005),and surgical time was significantly longer(152.1±44.4 min vs 127.4±38.4 min,P=0.045)in the stent-laparoscopy group than in the stent-open group.Surgery-related complications and the rate of admission to the intensive care unit were lower in the stent-laparoscopy group.There were no significant differences in the interval between stenting and surgery,intraoperative blood loss,OS,and DFS between the two stent groups.Compared with those in the stentlaparoscopy group,all surgery-related parameters,complications,OS,and DFS in the control group were comparable.CONCLUSION:The stent-laparoscopy approach is a feasible,rapid,and minimally invasive option for patients with ACO caused by left-sided CRC and can achieve a favorable long-term prognosis. 展开更多
关键词 Self-expandable metallic stent COLORECTAL cancer Endoscopy LAPAROSCOPY Efficiency Safety
下载PDF
Drug-eluting fully covered self-expanding metal stent for dissolution of bile duct stones in vitro 被引量:9
13
作者 Chao Huang Xiao-Bo Cai +3 位作者 Li-Li Guo Xiao-Sheng Qi Qiang Gao Xin-Jian Wan 《World Journal of Gastroenterology》 SCIE CAS 2019年第26期3370-3379,共10页
BACKGROUND The treatment of difficult common bile duct stones(CBDS)remains a big challenge around the world.Biliary stenting is a widely accepted rescue method in patients with failed stone extraction under endoscopic... BACKGROUND The treatment of difficult common bile duct stones(CBDS)remains a big challenge around the world.Biliary stenting is a widely accepted rescue method in patients with failed stone extraction under endoscopic retrograde cholangiopancreatography.Fully covered self-expanding metal stent(FCSEMS)has gained increasing attention in the management of difficult CBDS.AIM To manufacture a drug-eluting FCSEMS,which can achieve controlled release of stone-dissolving agents and speed up the dissolution of CBDS.METHODS Customized covered nitinol stents were adopted.Sodium cholate(SC)and disodium ethylene diamine tetraacetic acid(EDTA disodium,EDTA for short)were used as stone-dissolving agents.Three different types of drug-eluting stents were manufactured by dip coating(Stent I),coaxial electrospinning(Stent II),and dip coating combined with electrospinning(Stent III),respectively.The drugrelease behavior and stone-dissolving efficacy of these stents were evaluated in vitro to sort out the best manufacturing method.And the selected stonedissolving stents were further put into porcine CBD to evaluate their biosecurity.RESULTS Stent I and Stent II had obvious burst release of drugs in the first 5 d while Stent III presented controlled and sustainable drug release for 30 d.In still buffer,the final stone mass-loss rate of each group was 5.19%±0.69%for naked FCSEMS,20.37%±2.13%for Stent I,24.57%±1.45%for Stent II,and 33.72%±0.67%for Stent III.In flowing bile,the final stone mass-loss rate of each group was 5.87%±0.25%for naked FCSEMS,6.36%±0.48%for Stent I,6.38%±0.37%for Stent II,and 8.15%±0.27%for Stent III.Stent III caused the most stone mass-loss no matter in still buffer or in flowing bile,which was significantly higher than those of other groups(P<0.05).In vivo,Stent III made no difference from naked FCSEMS in serological analysis(P>0.05)and histopathological examination(P>0.05).CONCLUSION The novel SC and EDTA-eluting FCSEMS is efficient in diminishing CBDS in vitro.When conventional endoscopic techniques fail to remove difficult CBDS,SC and EDTA-eluting FCSEMS implantation may be considered a promising alternative. 展开更多
关键词 Common BILE duct stone DRUG-ELUTING stent Fully COVERED self-expanding metal stent Electrospinning NANOFIBER film
下载PDF
Temporary self-expanding metallic stents for achalasia: A prospective study with a long-term follow-up 被引量:10
14
作者 Ying-Sheng Cheng Fang Ma +5 位作者 Ying-Sheng Cheng Yong-Dong Li Jun-Gong Zhao Chun-Gen Wu Ni-Wei Chen Wei-Xiong Chen 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第40期5111-5117,共7页
AIM: To compare the efficacy of self-expanding metallic stents (SEMSs) for the long-term clinical treatment of achalasia. METHODS: Ninety achalasic patients were treated with a temporary SEMS with a diameter of 20 mm ... AIM: To compare the efficacy of self-expanding metallic stents (SEMSs) for the long-term clinical treatment of achalasia. METHODS: Ninety achalasic patients were treated with a temporary SEMS with a diameter of 20 mm (n = 30, group A), 25 mm (n = 30, group B) or 30 mm (n = 30, group C). Data on clinical symptoms, complications and treatment outcomes were collected, and follow-up was made at 6 mo and at 1, 3-5, 5-8, 8-10 and > 10 years, postoperatively.RESULTS: Stent placement was successful in all patients. Although chest pain occurrence was high, stent migration was less in group C than in groups A and B. The clinical remission rate at 5-8, 8-10 and > 10 years in group C was higher than that in the other two groups. The treatment failure rate was lower in group C (13%) than in groups A (53%) and B (27%). SEMSs in group C resulted in reduced dysphagia scores and lowered esophageal sphincter pressures, as well as normal levels of barium height and width during all the follow-up time periods. Conversely, these parameters increased over time in groups A and B. The primary patency in group C was longer than in groups A and B. CONCLUSION: A temporary SEMS with a diameter of 30 mm is associated with a superior long-term clinical efficacy in the treatment of achalasia compared with a SEMS with a diameter of 20 mm or 25 mm. 展开更多
关键词 ACHALASIA DYSPHAGIA Self-expanding metallic stents COMPARISON
下载PDF
Endoscopic transluminal pancreatic necrosectomy using a self-expanding metal stent and high-flow water-jet system 被引量:10
15
作者 István Hritz Roland Fejes +5 位作者 András Székely Iván Székely László Horváth gnes Sárkány ron Altorjay László Madácsy 《World Journal of Gastroenterology》 SCIE CAS 2013年第23期3685-3692,共8页
Walled-off pancreatic necrosis and a pancreatic abscess are the most severe complications of acute pancreatitis. Surgery in such critically ill patients is often associated with significant morbidity and mortality wit... Walled-off pancreatic necrosis and a pancreatic abscess are the most severe complications of acute pancreatitis. Surgery in such critically ill patients is often associated with significant morbidity and mortality within the first few weeks after the onset of symptoms. Minimal invasive approaches with high success and low mortality rates are therefore of considerable interest. Endoscopic therapy has the potential to offer safe and effective alternative treatment. We report here on 3 consecutive patients with infected walled-off pancreatic necrosis and 1 patient with a pancreatic abscess who underwent direct endoscopic necrosectomy 19-21 d after the onset of acute pancreatitis. The infected pancreatic necrosis or abscess was punctured transluminally with a cystostome and, after balloon dilatation, a non-covered self-expanding biliary metal stent was placed into the necrotic cavity. Following stent deployment, a nasobiliary pigtail catheter was placed into the cavity to ensure continuous irrigation. After 5-7 d, the metal stent was removed endoscopically and the necrotic cavity was entered with a therapeutic gastroscope. Endoscopic debridement was performed via the simultaneous application of a high-flow water-jet system; using a flush knife, a Dormia basket, and hot biopsy forceps. The transluminal endotherapy was repeated 2-5 times daily during the next 10 d. Supportive care included parenteral antibiotics and jejunal feeding. All patients improved dramatically and with resolution of their septic conditions; 3 patients were completely cured without any further complications or the need for surgery. One patient died from a complication of prolonged ventilation severe bilateral pneumonia, not related to the endoscopic procedure. No procedure related complications were observed. Transluminal endoscopic necrosectomy with temporary application of a self-expanding metal stent and a high-flow water-jet system shows promise for enhancing the potential of this endoscopic approach in patients with walled-off pancreatic necrosis and/or a pancreatic abscess. 展开更多
关键词 Acute NECROTIZING pancreatitis Walled off PANCREATIC necrosis ENDOSCOPIC NECROSECTOMY Selfexpanding metal stent Water-jet SYSTEM
下载PDF
Randomized trial in malignant biliary obstruction:Plastic vs partially covered metal stents 被引量:7
16
作者 Peter L Moses Khalid M AlNaamani +6 位作者 Alan N Barkun Stuart R Gordon Roger D Mitty M Stanley Branch Thomas E Kowalski Myriam Martel Viviane Adam 《World Journal of Gastroenterology》 SCIE CAS 2013年第46期8638-8646,共9页
AIM:To compare efficacy and complications of par-tially covered self-expandable metal stent(pcSEMS)to plastic stent(PS)in patients treated for malignant,infrahilar biliary obstruction.METHODS:Multicenter prospective r... AIM:To compare efficacy and complications of par-tially covered self-expandable metal stent(pcSEMS)to plastic stent(PS)in patients treated for malignant,infrahilar biliary obstruction.METHODS:Multicenter prospective randomized clinical trial with treatment allocation to a pcWallstent(SEMS)or a 10 French PS.Palliative patients aged≥18,for infrahilar malignant biliary obstruction and a Karnofsky performance scale index>60%from 6 participating North American university centers.Primary endpoint was time to stent failure,with secondary outcomes of death,adverse events,Karnofsky performance score and short-form-36 scale administered on a three-monthly basis for up to 2 years.Survival analyses were performed for stent failure and death,with Cox proportional hazards regression models to determine significant predictive characteristics.RESULTS:Eighty-five patients were accrued over 37mo,42 were randomized to the SEMS group and 83patients were available for analyses.Time to stent failure was 385.3±52.5 d in the SEMS and 153.3±19.8 d in the PS group,P=0.006.Time to death did not differ between groups(192.3±23.4 d for SEMS vs211.5±28.0 d for PS,P=0.70).The only significant predictor was treatment allocation,relating to the time to stent failure(P=0.01).Amongst other measured outcomes,only cholangitis differed,being more common in the PS group(4.9%vs 24.5%,P=0.029).The small number of patients in follow-up limits longitudinal assessments of performance and quality of life.From an initially planned 120 patients,only 85 patients were recruited.CONCLUSION:Partially covered SEMS result in a longer duration till stent failure without increased complication rates,yet without accompanying measurable benefits in survival,performance,or quality of life. 展开更多
关键词 Randomized BILIARY OBSTRUCTION stent PLASTIC metal PALLIATIVE Common BILE duct
下载PDF
Self-expanding metallic stents drainage for acute proximal colon obstruction 被引量:30
17
作者 Li-Qin Yao Yun-Shi Zhong Mei-Dong Xu Jian-Min Xu Ping-Hong Zhou Xian-Li Cai 《World Journal of Gastroenterology》 SCIE CAS CSCD 2011年第28期3342-3346,共5页
AIM: To clarify the usefulness of the self-expanding metallic stents (SEMS) in the management of acute proximal colon obstruction due to colon carcinoma before curative surgery.METHODS: Eighty-one colon (proximal to s... AIM: To clarify the usefulness of the self-expanding metallic stents (SEMS) in the management of acute proximal colon obstruction due to colon carcinoma before curative surgery.METHODS: Eighty-one colon (proximal to spleen flex) carcinoma patients (47 males and 34 females,aged 18-94 years,mean = 66.2 years) treated between September 2004 and June 2010 for acute colon obstruction were enrolled to this study,and their clinical and radiological features were reviewed.After a cleaning enema was administered,urgent colonoscopy was performed.Subsequently,endoscopic decompression using SEMS placement was attempted.RESULTS: Endoscopic decompression using SEMS placement was technically successful in 78 (96.3%) of 81 patients.Three patients’ symptoms could not be relieved after SEMS placement and emergent operation was performed 1 d later.The site of obstruction was transverse colon in 18 patients,the hepatic flex in 42,and the ascending colon in 21.Following adequate cleansing of the colon,patients’ abdominal girth was decreased from 88 ± 3 cm before drainage to 72 ± 6 cm 7 d later,and one-stage surgery after 8 ± 1 d (range,7-10 d) was performed.No anastomotic leakage or postoperative stenosis occurred after operation.CONCLUSION: SEMS placement is effective and safe in the management of acute proximal colon obstruction due to colon carcinoma,and is considered as a bridged method before curative surgery. 展开更多
关键词 ENDOSCOPE Proximal colon cancer OBSTRUCTION Self-expanding metallic stents Drainage
下载PDF
Evaluation of fully covered self-expanding metal stents in benign biliary strictures and bile leaks 被引量:9
18
作者 David Lalezari Inder Singh +1 位作者 Sofiya Reicher Viktor Ernst Eysselein 《World Journal of Gastrointestinal Endoscopy》 CAS 2013年第7期332-339,共8页
AIM: To investigate the use of fully covered metal stents in benign biliary strictures (BBS) and bile leaks. METHODS: We studied 17 patients, at Harbor-UCLA Medical center (Los Angeles), with BBS (n=12) and bile leaks... AIM: To investigate the use of fully covered metal stents in benign biliary strictures (BBS) and bile leaks. METHODS: We studied 17 patients, at Harbor-UCLA Medical center (Los Angeles), with BBS (n=12) and bile leaks (n=5) from July 2007 to February 2012 that had received placement of fully covered self-expanding metal stents (FCSEMs). Fourteen patients had endoscopic placement of VIABIL (Conmed, Utica, New York, United States) stents and three had Wallflex (Boston Scientific, Mass) stents. FCSEMS were 8 mm or 10 mm in diameter and 4 cm to 10 cm in length. Patients were followed at regular intervals to evaluate for symptoms and liver function tests. FCSEMS were removed after 4 or more weeks. Resolution of BBS and leak was documented cholangiographically following stent removal. Stent patency can be defined as adequate bile and contrast flow from the stent and into the ampulla during endoscopic retrograde cholangiopancreatography (ERCP) without clinical signs and/or symptoms of biliary obstruction. Criterion for bile leak resolution at ERCP is defined as absence of contrast extravasation from the common bile duct, cystic duct remanent, or gall blad-der fossa. Rate of complications such as migration, and instent occlusion were recorded. Failure of endoscopic therapy was defined as persistent biliary stenosis or continuous biliary leakage after 12 mo of stent placement. RESULTS: All 17 patients underwent successful FC- SEMS placement and removal. Etiologies of BBS included: cholecystectomies (n=8), cholelithiasis (n=2), hepatic artery compression (n=1), pancreatitis (n=2), and Whipple procedure (n=1). All bile leaks occurred following cholecystectomy. The anatomic location of BBS varied: distal common bile duct (n=7), common hepatic duct (n=1), hepaticojejunal anastomosis (n=2), right intrahepatic duct (n=1), and choledochoduo-denal anastomatic junction (n=1). All bile leaks were found to be at the cystic duct. Twelve of 17 patients had failed prior stent placement or exchange. Resolution of the biliary strictures and bile leaks was achieved in 16 of 17 patients (94%). The overall median stent time was 63 d (range 27-251 d). The median stent time for the BBS group and bile leak group was 62 ± 58 d (range 27-199 d) and 92 ± 81 d (range 48-251 d), respectively. All 17 patients underwent successful FCSEMS removal. Long term follow-up was obtained for a median of 575 d (range 28-1435 d). Complications occurred in 5 of 17 patients (29%) and included: migration (n=2), stent clogging (n=1), cholangitis (n=1), and sepsis with hepatic abscess (n=1). CONCLUSION: Placement of fully covered self-expanding metal stents may be used in the management of benign biliary strictures and bile leaks with a low rate of complications. 展开更多
关键词 BILE LEAKS Benign BILIARY STRICTURE Fully COVERED metal stentS BILIARY disease
下载PDF
A temporary self-expanding metallic stent for malignant colorectal obstruction 被引量:5
19
作者 Xiao-Li Ding Yong-Dong Li +2 位作者 Rui-Min Yang Fen-Bao Li Ming-Qiu Zhang 《World Journal of Gastroenterology》 SCIE CAS 2013年第7期1119-1123,共5页
AIM:To investigate the clinical safety and efficacy of a temporary self-expanding metallic stent(SEMS) for malignant colorectal obstruction.METHODS:From September 2007 to June 2012,33 patients with malignant colorecta... AIM:To investigate the clinical safety and efficacy of a temporary self-expanding metallic stent(SEMS) for malignant colorectal obstruction.METHODS:From September 2007 to June 2012,33 patients with malignant colorectal obstruction were treated with a temporary SEMS.The stent had a tubular configuration with a retrieval lasso attached inside the proximal end of the stent to facilitate its removal.The SEMS was removed one week after placement.Clinical examination,abdominal X-ray and a contrast study were prospectively performed and both initial and follow-up data before and at 1 d,1 wk,and 1 mo,3 mo,6 mo and 12 mo after stent placement were obtained.Data collected on the technical and clinical success of the procedures,complications,need for reinsertion and survival were analyzed.RESULTS:Stent placement and removal were technically successful in all patients with no procedurerelated complications.Post-procedural complications included stent migration(n = 2) and anal pain(n = 2).Clinical success was achieved in 31(93.9%) of 33 patients with resolution of bowel obstruction within 3 d of stent removal.Eleven of the 33 patients died 73.81 ± 23.66 d(range 42-121 d) after removal of the stent without colonic re-obstruction.Clinical success was achieved in another 8 patients without symptoms of obstruction during the follow-up period.Reinsertion of the stent was performed in the remaining 12 patients with re-obstruction after 84.33 ± 51.80 d of follow-up.The mean and median periods of relief of obstructive symptoms were 97.25 ± 9.56 d and 105 ± 17.43 d,respectively,using Kaplan-Meier analysis.CONCLUSION:Temporary SEMS is a safe and effective approach in patients with malignant colorectal obstruction due to low complication rates and good medium-term outcomes. 展开更多
关键词 Self-expanding metallic stentS COLORECTUM MALIGNANT OBSTRUCTION Complications
下载PDF
Bilateral vs unilateral placement of metal stents for inoperable highgrade hilar biliary strictures: A systemic review and meta-analysis 被引量:6
20
作者 Munish Ashat Sumant Arora +3 位作者 Jagpal S Klair Christopher A Childs Arvind R Murali Frederick C Johlin 《World Journal of Gastroenterology》 SCIE CAS 2019年第34期5210-5219,共10页
BACKGROUND Bilateral vs unilateral biliary stenting is used for palliation in malignant biliary obstruction.No clear data is available to compare the efficacy and safety of bilateral biliary stenting over unilateral s... BACKGROUND Bilateral vs unilateral biliary stenting is used for palliation in malignant biliary obstruction.No clear data is available to compare the efficacy and safety of bilateral biliary stenting over unilateral stenting.AIM To assess the efficacy and safety of bilateral vs unilateral biliary drainage in inoperable malignant hilar obstruction.METHODS PubMed,Embase,Scopus,and Cochrane databases,as well as secondary sources(bibliographic review of selected articles and major GI proceedings),were searched through January 2019.The primary outcome was the re-intervention rate.Secondary outcomes were a technical success,early and late complications,and stent malfunction rate.Pooled odds ratio(OR)and 95%confidence interval(CI)were calculated for each outcome.RESULTS A total of 9 studies were included(2 prospective Randomized Controlled Study,5 retrospective studies,and 2 abstracts),involving 782 patients with malignant hilar obstruction.Bilateral stenting had significantly lower re-intervention rate compared with unilateral drainage(OR=0.59,95%CI:0.40-0.87,P=0.009).There was no difference in the technical success rate(OR=0.7,CI:0.42-1.17,P=0.17),early complication rate(OR=1.56,CI:0.31-7.75,P=0.59),late complication rate(OR=0.91,CI:0.58-1.41,P=0.56)and stent malfunction(OR=0.69,CI:0.42-1.12,P=0.14)between bilateral and unilateral stenting for malignant hilar biliary strictures.CONCLUSION Bilateral biliary drainage had a lower re-intervention rate as compared to unilateral drainage for high grade inoperable malignant biliary strictures,with no significant difference in technical success,and early or late complication rates. 展开更多
关键词 metal stent HILAR BILIARY STRICTURE Re-intervention RATE Technical success RATE