BACKGROUND Traditional esophagogastroduodenoscopy(EGD),an invasive examination method,can cause discomfort and pain in patients.In contrast,magnetically controlled capsule endoscopy(MCE),a noninvasive method,is being ...BACKGROUND Traditional esophagogastroduodenoscopy(EGD),an invasive examination method,can cause discomfort and pain in patients.In contrast,magnetically controlled capsule endoscopy(MCE),a noninvasive method,is being applied for the detection of stomach and small intestinal diseases,but its application in treating esophageal diseases is not widespread.AIM To evaluate the safety and efficacy of detachable string MCE(ds-MCE)for the diagnosis of esophageal diseases.METHODS Fifty patients who had been diagnosed with esophageal diseases were pros-pectively recruited for this clinical study and underwent ds-MCE and conven-tional EGD.The primary endpoints included the sensitivity,specificity,positive predictive value,negative predictive value,and diagnostic accuracy of ds-MCE for patients with esophageal diseases.The secondary endpoints consisted of visualizing the esophageal and dentate lines,as well as the subjects'tolerance of the procedure.RESULTS Using EGD as the gold standard,the sensitivity,specificity,positive predictive value,negative predictive value,and diagnostic accuracy of ds-MCE for esophageal disease detection were 85.71%,86.21%,81.82%,89.29%,and 86%,respectively.ds-MCE was more comfortable and convenient than EGD was,with 80%of patients feeling that ds-MCE examination was very comfortable or comfortable and 50%of patients believing that detachable string v examination was very convenient.CONCLUSION This study revealed that ds-MCE has the same diagnostic effects as traditional EGD for esophageal diseases and is more comfortable and convenient than EGD,providing a novel noninvasive method for treating esophageal diseases.展开更多
Plasma sterilization is a new generation of high-tech sterilization method that is fast,safe,and pollution free.It is widely used in medical,food,and environmental protection fields.Home air sterilization is an emergi...Plasma sterilization is a new generation of high-tech sterilization method that is fast,safe,and pollution free.It is widely used in medical,food,and environmental protection fields.Home air sterilization is an emerging field of plasma application,which puts higher requirements on the miniaturization,operational stability,and operating cost of plasma device.In this study,a novel magnetically driven rotating gliding arc(MDRGA)discharge device was used to sterilize Lactobacillus fermentation.Compared with the traditional gas-driven gliding arc,this device has a simple structure and a more stable gliding arc.Simulation using COMSOL Multiphysics showed that adding permanent magnets can form a stable magnetic field,which is conducive to the formation of gliding arcs.Experiments on the discharge performance,ozone concentration,and sterilization effect were conducted using different power supply parameters.The results revealed that the MDRGA process can be divided into three stages:starting,gliding,and extinguishing.Appropriate voltage was the key factor for stable arc gliding,and both high and low voltages were not conducive to stable arc gliding and ozone production.In this experimental setup,the sterilization effect was the best at 6.6 kV.A high modulation duty ratio was beneficial for achieving stable arc gliding.However,when the duty ratio exceeded a certain value,the improvement in the sterilization effect was slow.Therefore,considering the sterilization effect and energy factors comprehensively,we chose 80%as the optimal modulation duty ratio for this experimental device.展开更多
Objective:Magnetically controlled capsule gastroscopy(MCCG)is an effective method for screening gastric diseases;however,its performance may be affected by gastric cleanliness.We aimed to explore the correlation betwe...Objective:Magnetically controlled capsule gastroscopy(MCCG)is an effective method for screening gastric diseases;however,its performance may be affected by gastric cleanliness.We aimed to explore the correlation between Helicobacter pylori infection and the degree of gastric cleanliness in the MCCG.Methods:This retrospective study enrolled 297 participants from October 2020 to April 2024 at Sir Run Run Shaw Hospital,Zhejiang University School of Medicine.Participant characteristics,MCCG examination results,and(13)C-urea breath test(C13-UBT)results were collected.The gastric cleanliness in MCCG examinations was assessed using a gastric cleanliness score.Binary logistic regression was used to analyze the relationships among participant characteristics,H.pylori infection,and gastric cleanliness.Chi-square tests and Fisher's exact tests were used to analyze the relationships among gastric lesions,H.pylori infection,and gastric cleanliness.Results:Among the participants,24.2%had H.pylori infection,and 17.5%had poor gastric cleanliness.Hypertension(odds ratio[OR]:2.63;95%confidence interval[CI]:1.36e5.09;p?0.004)was associated with a greater likelihood of H.pylori infection.H.pylori infection(OR:3.76;95%CI:1.99e7.09;p<0.001)was an independent risk factor for poor gastric cleanliness in the MCCG.A significant disparity was noted in the prevalence of focal erosions(p<0.001),gastric ulcers(p?0.001),and positive gastric lesions(p?0.027)between the 2 groups with and without H.pylori infection.The proportion of positive gastric lesions was not significantly different between the good gastric cleanliness group and the poor gastric cleanliness group(25.7%vs.21.2%;p?0.490).Conclusion:The findings of this study revealed that H.pylori infection was associated with hypertension.H.pylori infection may lead to poor gastric cleanliness.Institutions are advised to perform C13-UBT before MCCG,and participants should be informed of the risk of poor gastric cleanliness if the results are positive.The decision to perform H.pylori eradication before MCCG should take into account patient willingness and the benefit-to-risk ratio.展开更多
This paper gives a summary of the organization and the presentations delivered at the 10th Conference on Magnetically Confined Fusion Theory and Simulation(CMCFTS)held in Zhuhai,China,from 28th to 31st October 2022.Th...This paper gives a summary of the organization and the presentations delivered at the 10th Conference on Magnetically Confined Fusion Theory and Simulation(CMCFTS)held in Zhuhai,China,from 28th to 31st October 2022.The conference focused on the latest progress in the research of the magnetic confined fusion plasma theory and simulations,as well as the largescale numerical simulation techniques developed in recent years.This conference is held both online and offline,with about 110 domestic participants from 18 institutes participating in the live conference,and the statistical data from the live broadcast platform indicated that the online conference attracted over 20000 views per day.A summary of the conference is given,and the history of the CMCFTS is presented.A brief introduction to the poster section is also included in this paper.展开更多
Magnetically coupled rodless cylinders are widely used in the coordinate positioning of mechanical arms,electro-static paintings,and other industrial applications.However,they exhibit strong nonlinear characteristics,...Magnetically coupled rodless cylinders are widely used in the coordinate positioning of mechanical arms,electro-static paintings,and other industrial applications.However,they exhibit strong nonlinear characteristics,which lead to low servo control accuracy.In this study,a mass-flow equation through the valve port was derived to improve the control performance,considering the characteristics of the dynamics and throttle-hole flow.Subsequently,a fric-tion model combining static,viscous,and Coulomb friction with a zero-velocity interval was proposed.In addition,energy and dynamic models were set for the experimental investigation of the magnetically coupled rodless cylin-der.A nonlinear mathematical model for the position of the magnetically coupled rodless cylinder was proposed.An incremental PID controller was designed for the magnetically coupled rodless cylinder to control this system,and the PID parameters were adjusted online using RBF neural network.The response results of the PID parameters based on the RBF neural network were compared with those of the traditional incremental PID control,which proved the superiority of the optimization control algorithm of the incremental PID parameters based on the RBF neural network servo control system.The experimental results of this model were compared with the simulation results.The average error between the established model and the actual system was 0.005175054(m),which was approximately 2.588%of the total travel length,demonstrating the accuracy of the theoretical model.展开更多
Magnetically coupled resonant technology is a novel method for solving the breakpoint locating of power grounding grid.But the method can only detect breakpoints of a single mesh grounding grid at present.In this pape...Magnetically coupled resonant technology is a novel method for solving the breakpoint locating of power grounding grid.But the method can only detect breakpoints of a single mesh grounding grid at present.In this paper,a magnetically coupled resonant detection method for four-hole grounding grid breakpoint is proposed.Firstly,the equivalent circuit model of the four mesh grounding grid with two types of breakpoints,namely edge branch and intermediate branch,is established.The input impedance and phase angle of the system are obtained by analyzing the equivalent capacitance and equivalent resistance in the model.Secondly,the magnetically coupled resonant physical process of grounding grid faults is solved via HFSS software.The magnetic field intensity and phase frequency characteristic curves of four mesh holes with different branches and positions of breakpoints and different corrosion degrees are studied,and an experimental system is built to verify the feasibility.The results show that under the condition of grounding grid buried depth of 0.5 m and input frequency of 1~15MHz,and there is an inverse relationship between equivalent capacitance and distortion frequency,the phase angle is positively correlated with the degree of corrosion of grounding grid,and the error of signal distortion frequency can be positioned at 5%.This paper provides some ideas for the application of magnetic coupling grounding grid detection technology.展开更多
For three-dimensional vector fields,the governing formula of invariant manifolds grown from a hyperbolic cycle is given in cylindrical coordinates.The initial growth directions depend on the Jacobians of Poincaré...For three-dimensional vector fields,the governing formula of invariant manifolds grown from a hyperbolic cycle is given in cylindrical coordinates.The initial growth directions depend on the Jacobians of Poincarémap on that cycle,for which an evolution formula is deduced to reveal the relationship among Jacobians of different Poincarésections.The evolution formula also applies to cycles in arbitrary finite n-dimensional autonomous continuous-time dynamical systems.Non-Möbiusian/Möbiusian saddle cycles and a dummy X-cycle are constructed analytically as demonstration.A real-world numeric example of analyzing a magnetic field timeslice on EAST is presented.展开更多
The demand for electric vehicles has increased over the past few years.Wireless power transfer for electric vehicles provides more flexibility than traditional plug-in charging technology.Charging couplers are critica...The demand for electric vehicles has increased over the past few years.Wireless power transfer for electric vehicles provides more flexibility than traditional plug-in charging technology.Charging couplers are critical components in wireless power transfer systems.The thermal effect produced by the magnetic coupler in work will cause the temperature of the device to rise rapidly,affecting the work efficiency,transfer power,operation reliability,and service life.This paper modeled and analyzed each component's temperature distribution characteristics and thermal behavior.Firstly,the magnetic coupler's mutual inductance and magnetic circuit model are established,and the thermal model of the magnetic coupler analyzes the heat generation process.The thermal models of the coupler under three different magnetic core distributions are established,and the temperature rise of each component is obtained.The temperature rise of different parts of the coupler is verified by the temperature rise test structure of the experiment.展开更多
To determine and calculate the stable fluidization zone in a magnetically fluidized bed, the fluidization characteristics of magnetic particles are investigated. Four kinds of magnetic particles with different average...To determine and calculate the stable fluidization zone in a magnetically fluidized bed, the fluidization characteristics of magnetic particles are investigated. Four kinds of magnetic particles with different average diameters, ranging from 231 to 512 μm, are fluidized in the presence of magnetic fields with specified values of the intensity in the range of zero to 7330 A/m, and the particle fluidization curves are plotted. For marking the stable fluidization zone in the curves, the minimum bubbling velocities of particles are measured by the pressure-drop fluctuation. Based on the fluidization curves, the influences of the average particle diameter and magnetic field intensity on the zone are analyzed and discussed. A correlation to determine the stable fluidization zone is derived from the experimental data, using three dimensionless numbers, i. e., the ratio of magnetic potential to gravity potential, the Reynolds number and the Archimedes number. Compared with available data reported, it is shown that the correlation is more simplified to predict relative parameters for the bed operating in the state of stable fluidization under reasonable conditions.展开更多
The static and dynamic magnetic controlling characteristics of NiMnGa magnetically controlled shape memory alloy (MSMA) were experimentally studied. The results show that the characteristics of induced strain with r...The static and dynamic magnetic controlling characteristics of NiMnGa magnetically controlled shape memory alloy (MSMA) were experimentally studied. The results show that the characteristics of induced strain with respect to the magnetic field are nonlinear with saturation nature, and dependent on the temperature as well as the load applied to the MSMA. The magnetic shape memory effect can be observed only in complete martensite phase at room temperature. The magnetic permeability of MSMA is not constant and reduces with the increment of magnetic field. The relative saturation magnetic permeability of MSMA is about 1.5.展开更多
A magnetically separable photocatalyst TiO2/SiO2/NiFe2O4 (TSN) with a typical ferromagnetic hysteresis was prepared by a liquid catalytic phase transfer method. When the intensity of applied magnetic field weakened ...A magnetically separable photocatalyst TiO2/SiO2/NiFe2O4 (TSN) with a typical ferromagnetic hysteresis was prepared by a liquid catalytic phase transfer method. When the intensity of applied magnetic field weakened to zero, the remnant magnetism of the prepared photocatalyst faded to zero. The photocatalytst can be separated from water when an external magnetic field is added and redispersed into aqueous solution after the external magnetic field is eliminated, that makes the photocatalysts promising for wastewater treatment. Transmission electron microscope (TEM) and X-ray diffractometer (XRD) were used to characterize the structure of the photocatalyst indicating that the magnetic SiOffNiFe204 (SN) particle was compactly enveloped by P-25 titania and Tit2 shell was formed. The magnetic composite showed high photocatalytic activity for the degradation of methyl orange in water. A thin SiO2 layer between NiFe2O4 and TiO2 shell prevented effectively the leakage of charges from TiO2 particles to NiFe2O4, which gave rise to the increase in photocatalytic activity. Moreover, the experiment on recycled use of TSN demonstrated a good repeatability of the photocatalytic activity.展开更多
AIM To design a miniature magnetically anchored and controlled camera system to reduce the number of trocars which are required for laparoscopy.METHODS The system consists of a miniature magnetically anchored camera w...AIM To design a miniature magnetically anchored and controlled camera system to reduce the number of trocars which are required for laparoscopy.METHODS The system consists of a miniature magnetically anchored camera with a 30° downward angle, an external magnetically anchored unit, and a vision output device. The camera weighs 12 g, measures Φ10.5 mm × 55 mm and has two magnets, a vision model, a light source, and a metal hexagonal nut. To test the prototype, the camera was inserted through a 12-mm conventional trocar in an ex vivo real liver laparoscopic training system. A trocar-less laparoscopic cholecystectomy was performed 6 times using a 12-mm and a 5-mm conventional trocar. In addition, the same procedure was performed in four canine models.RESULTS Both procedures were successfully performed using only two conventional laparoscopic trocars. The cholecystectomy was completed without any major complication in 42 min(38-45 min) in vitro and in 50 min(45-53 min) using an animal model. This camera was anchored and controlled by an external unit magnetically anchored on the abdominal wall. The camera could generate excellent image. with no instrument collisions.CONCLUSION The camera system we designed provides excellent optics and can be easily maneuvered. The number of conventional trocars is reduced without adding technical difficulties.展开更多
An X-band magnetically insulated transmission line oscillator (MILO) is designed and investigated numerically and experimentally for the first time. The X-band MILO is optimized in detail with KARAT code. In simulat...An X-band magnetically insulated transmission line oscillator (MILO) is designed and investigated numerically and experimentally for the first time. The X-band MILO is optimized in detail with KARAT code. In simulation, the X-band MILO, driven by a 720 kV, 53 kA electron beam, comes to a nonlinear steady state in 4.0 ns. High-power microwaves (HPM) of TEM mode is generated with an average power of 4.1 GW, a frequency of 9.3 GHz, and power conversion efficiency of 10.870 in durations of 0-40 ns. The device is fabricated according to the simulation results. In experiments, when the voltage is 400 kV and the current is 50 kA, the radiated microwave power reaches about 110 MW and the dominating frequency is 9.7GHz. Because the surfaces of the cathode end and the beam dump are destroyed, the diode voltage cannot increase continuously. However, when the diode voltage is 400 kV, the average power output is obtained to be 700 MW in simulation. The impedance of the device is clearly smaller than the simulation prediction. Moreover, the duration of the microwave pulse is obviously shorter than that of the current pulse. The experimental results are greatly different from the simulation predictions. The preliminary analyses show that the generations of the anode plasma, the cathode flare and the anode flare are the essential cause for the remarkable deviation of the experimental results from the simulation predictions.展开更多
A magnetically stabilized fluidized bed (MSB) is a highly efficient filter that takes the advantage of both fluidized beds and fixed beds. This paper presents the research to collect aerosol in airflow with a MSB. The...A magnetically stabilized fluidized bed (MSB) is a highly efficient filter that takes the advantage of both fluidized beds and fixed beds. This paper presents the research to collect aerosol in airflow with a MSB. The filtering model of MSB is established with its parameters including magnetic Geld intensity, gas superficial velocity, average grain-size, and bed height on the collection efficiency of MSB. The model is verified by experiments.展开更多
FeSiAl magnetically soft alloy hollow microspheres(MSAHMs) were prepared by self-reactive quenching technology based on Fe + Si + AI + KNO_3 reactive systems, in order to obtain absorbents with light weight, low frequ...FeSiAl magnetically soft alloy hollow microspheres(MSAHMs) were prepared by self-reactive quenching technology based on Fe + Si + AI + KNO_3 reactive systems, in order to obtain absorbents with light weight, low frequency and high efficiency. Firstly, twice-balling adhesive precursor method was used to obtain FeSiAl magnetically soft alloy agglomerate powders. Then agglomerate powders with the mesh number of 150-240, 240-325 and 325-400 were sprayed through the flame field into the quenching water. At last, FeSiAl MSAHMs with coarse(average at 86.97 μm), medium(average at 52.16 μm) and fine particles(average at 31.80 μm) were got. Effect of particle size on the phases and microwave absorption properties in low frequency band was studied by XRD and vector network analyzer. The results show that,Fe_3 Si_(0.7)Al_(0.3) and Fe_3 Si_(0.5)Al_(0.5) appear in the phase components of FeSiAl MSAHMs,which is important to improve the microwave absorption properties in low frequency. In addition, the real part(ε′) and imaginary part(ε″) of complex permittivity, the real part(μ′) and imaginary part(μ″) of complex permeability of FeSiAl MSAHMs all present the trend of fine particles > medium particles > coarse particles. The microwave absorption properties in low frequency are improved with the increasing of particle size, and the absorption peak moves to lower frequency range. The properties of fine particles are the best. Their matching thickness of samples is at 5 mm, and the minimum reflectivity is-43 dB at this thickness. The absorption frequency band lower than-10 dB is 4.6-7.6 GHz with a bandwidth of 3 GHz.展开更多
An arc channel tends to shrink due to its conductivity increasing with the increase of temperature. In this study, to generate large area arc plasma, we construct a magnetically rotating arc plasma generator, which ma...An arc channel tends to shrink due to its conductivity increasing with the increase of temperature. In this study, to generate large area arc plasma, we construct a magnetically rotating arc plasma generator, which mainly consists of a lanthanide tungsten cathode (13 mm in diameter), a concentric cylindrical graphite anode chamber (60 nun in diameter) and a solenoid coil for producing an axial magnet field. By controlling the cold gas flow, the magnetically rotating arc evolves from constricted mode to diffuse mode, which almost fills the whole arc chamber cross section. Results show that the diffuse arc plasma has better uniformity and stability. The formation mechanism of large area arc plasma is discussed in this paper.展开更多
A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/...A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/cm. In the paper, the current loss of an MITL made of stainless steel, which is usually used in large pulse power generators, is experimentally studied, and possible mechanisms to explain the current loss of the MITL are analyzed and discussed. From the experimental results, the relationship between loss current density and input current density follows approximately a power law. The loss is also related to the configuration of the MITL.展开更多
Magnetically dispersed arc plasma exhibits typically dispersed uniform arc column as well as diffusive cathode root and diffusive anode root. In this paper magnetically dispersed arc plasma coupled with solid cathod...Magnetically dispersed arc plasma exhibits typically dispersed uniform arc column as well as diffusive cathode root and diffusive anode root. In this paper magnetically dispersed arc plasma coupled with solid cathode is numerically simulated by the simplified cathode sheath model of LOWKE . The numerical simulation results in argon show that the maximum value of arc root current density on the cathode surface is 3.5×10^7 A/m^2), and the maximum value of energy flux on the cathode surface is 3× 10^7 J/m^2, both values are less than the average values of a contracted arc, respectively.展开更多
Axial liquid dispersion was experimentally studied in liquid-solid and gas-liquid-solid magnetically stabilized beds using the ferromagnetic catalyst of SRNA-4 as the solid phase. The effects of operating factors and ...Axial liquid dispersion was experimentally studied in liquid-solid and gas-liquid-solid magnetically stabilized beds using the ferromagnetic catalyst of SRNA-4 as the solid phase. The effects of operating factors and fluid characters, such as superficial liquid velocity, superficial gas velocity, magnetic field intensity, liquid viscosity and surface tension, on axial dispersion coefficients of liquid were investigated. The dispersion coefficients increased with the increase of superficial liquid velocity and superficial gas velocity, and decreased with the increase of liquid viscosity, liquid surface tension and magnetic field intensity. A correlation equation of Peclet number was obtained for both liquid-solid and gas-liquid-solid magnetically stabilized bed.展开更多
Magnetically modified palygorskite composites were synthesized with γ-Fe2O3 dispersing on the external surface of clay mineral. The magnetic clay was characterized with Fourier transform infrared, X-ray diffrac- tion...Magnetically modified palygorskite composites were synthesized with γ-Fe2O3 dispersing on the external surface of clay mineral. The magnetic clay was characterized with Fourier transform infrared, X-ray diffrac- tion, transmission electron microscopy, and vibrating sample magnetometer. Candida sp. 99-125 lipase was immobilized on magnetic palygorskite composites by physical adsorption with enzyme loading of 41.5 mg· g^-1 support and enzyme activity of 2631.6 U· (g support)^-1. The immobilized lipase exhibit better thermal and broader pH stability and excellent reusabilitV compared with free lipase.展开更多
基金the Science and Technology Commission of Shanghai,No.18DZ1930309.
文摘BACKGROUND Traditional esophagogastroduodenoscopy(EGD),an invasive examination method,can cause discomfort and pain in patients.In contrast,magnetically controlled capsule endoscopy(MCE),a noninvasive method,is being applied for the detection of stomach and small intestinal diseases,but its application in treating esophageal diseases is not widespread.AIM To evaluate the safety and efficacy of detachable string MCE(ds-MCE)for the diagnosis of esophageal diseases.METHODS Fifty patients who had been diagnosed with esophageal diseases were pros-pectively recruited for this clinical study and underwent ds-MCE and conven-tional EGD.The primary endpoints included the sensitivity,specificity,positive predictive value,negative predictive value,and diagnostic accuracy of ds-MCE for patients with esophageal diseases.The secondary endpoints consisted of visualizing the esophageal and dentate lines,as well as the subjects'tolerance of the procedure.RESULTS Using EGD as the gold standard,the sensitivity,specificity,positive predictive value,negative predictive value,and diagnostic accuracy of ds-MCE for esophageal disease detection were 85.71%,86.21%,81.82%,89.29%,and 86%,respectively.ds-MCE was more comfortable and convenient than EGD was,with 80%of patients feeling that ds-MCE examination was very comfortable or comfortable and 50%of patients believing that detachable string v examination was very convenient.CONCLUSION This study revealed that ds-MCE has the same diagnostic effects as traditional EGD for esophageal diseases and is more comfortable and convenient than EGD,providing a novel noninvasive method for treating esophageal diseases.
基金supported by National Natural Science Foundation of China(Nos.52077129 and 52277150)the Natural Science Foundation of Shandong Province(No.ZR2022ME037).
文摘Plasma sterilization is a new generation of high-tech sterilization method that is fast,safe,and pollution free.It is widely used in medical,food,and environmental protection fields.Home air sterilization is an emerging field of plasma application,which puts higher requirements on the miniaturization,operational stability,and operating cost of plasma device.In this study,a novel magnetically driven rotating gliding arc(MDRGA)discharge device was used to sterilize Lactobacillus fermentation.Compared with the traditional gas-driven gliding arc,this device has a simple structure and a more stable gliding arc.Simulation using COMSOL Multiphysics showed that adding permanent magnets can form a stable magnetic field,which is conducive to the formation of gliding arcs.Experiments on the discharge performance,ozone concentration,and sterilization effect were conducted using different power supply parameters.The results revealed that the MDRGA process can be divided into three stages:starting,gliding,and extinguishing.Appropriate voltage was the key factor for stable arc gliding,and both high and low voltages were not conducive to stable arc gliding and ozone production.In this experimental setup,the sterilization effect was the best at 6.6 kV.A high modulation duty ratio was beneficial for achieving stable arc gliding.However,when the duty ratio exceeded a certain value,the improvement in the sterilization effect was slow.Therefore,considering the sterilization effect and energy factors comprehensively,we chose 80%as the optimal modulation duty ratio for this experimental device.
基金supported by the General Research Project of the Department of Education of Zhejiang Province,China(No.Y202351338)the Soft Science Project of the Department of Science and Technology of Zhejiang Province,China(No.2024C35054).
文摘Objective:Magnetically controlled capsule gastroscopy(MCCG)is an effective method for screening gastric diseases;however,its performance may be affected by gastric cleanliness.We aimed to explore the correlation between Helicobacter pylori infection and the degree of gastric cleanliness in the MCCG.Methods:This retrospective study enrolled 297 participants from October 2020 to April 2024 at Sir Run Run Shaw Hospital,Zhejiang University School of Medicine.Participant characteristics,MCCG examination results,and(13)C-urea breath test(C13-UBT)results were collected.The gastric cleanliness in MCCG examinations was assessed using a gastric cleanliness score.Binary logistic regression was used to analyze the relationships among participant characteristics,H.pylori infection,and gastric cleanliness.Chi-square tests and Fisher's exact tests were used to analyze the relationships among gastric lesions,H.pylori infection,and gastric cleanliness.Results:Among the participants,24.2%had H.pylori infection,and 17.5%had poor gastric cleanliness.Hypertension(odds ratio[OR]:2.63;95%confidence interval[CI]:1.36e5.09;p?0.004)was associated with a greater likelihood of H.pylori infection.H.pylori infection(OR:3.76;95%CI:1.99e7.09;p<0.001)was an independent risk factor for poor gastric cleanliness in the MCCG.A significant disparity was noted in the prevalence of focal erosions(p<0.001),gastric ulcers(p?0.001),and positive gastric lesions(p?0.027)between the 2 groups with and without H.pylori infection.The proportion of positive gastric lesions was not significantly different between the good gastric cleanliness group and the poor gastric cleanliness group(25.7%vs.21.2%;p?0.490).Conclusion:The findings of this study revealed that H.pylori infection was associated with hypertension.H.pylori infection may lead to poor gastric cleanliness.Institutions are advised to perform C13-UBT before MCCG,and participants should be informed of the risk of poor gastric cleanliness if the results are positive.The decision to perform H.pylori eradication before MCCG should take into account patient willingness and the benefit-to-risk ratio.
基金supported by the National Magnetic Confinement Fusion Energy Research and Development Program of China(No.2019YFE03090100)。
文摘This paper gives a summary of the organization and the presentations delivered at the 10th Conference on Magnetically Confined Fusion Theory and Simulation(CMCFTS)held in Zhuhai,China,from 28th to 31st October 2022.The conference focused on the latest progress in the research of the magnetic confined fusion plasma theory and simulations,as well as the largescale numerical simulation techniques developed in recent years.This conference is held both online and offline,with about 110 domestic participants from 18 institutes participating in the live conference,and the statistical data from the live broadcast platform indicated that the online conference attracted over 20000 views per day.A summary of the conference is given,and the history of the CMCFTS is presented.A brief introduction to the poster section is also included in this paper.
基金Supported by Outstanding Young Scientists in Beijing of China(Grant No.BJJWZYJH01201910006021)Open Foundation of the State Key Laboratory of Fluid Power and Mechatronic Systems of China(Grant No.GZKF-202016)+2 种基金Henan Provincial Science and Technology Key Project of China(Grant Nos.202102210081,212102210050)Sub Project of Strengthening Key Basic Research Projects in the Basic Plan of the Science and Technology Commission of the Central Military Commission of China(Grant No.2019-JCJQ-ZD-120-13)Henan Provincial Fundamental Research Funds for the Universities of China(Grant No.NSFRF200403).
文摘Magnetically coupled rodless cylinders are widely used in the coordinate positioning of mechanical arms,electro-static paintings,and other industrial applications.However,they exhibit strong nonlinear characteristics,which lead to low servo control accuracy.In this study,a mass-flow equation through the valve port was derived to improve the control performance,considering the characteristics of the dynamics and throttle-hole flow.Subsequently,a fric-tion model combining static,viscous,and Coulomb friction with a zero-velocity interval was proposed.In addition,energy and dynamic models were set for the experimental investigation of the magnetically coupled rodless cylin-der.A nonlinear mathematical model for the position of the magnetically coupled rodless cylinder was proposed.An incremental PID controller was designed for the magnetically coupled rodless cylinder to control this system,and the PID parameters were adjusted online using RBF neural network.The response results of the PID parameters based on the RBF neural network were compared with those of the traditional incremental PID control,which proved the superiority of the optimization control algorithm of the incremental PID parameters based on the RBF neural network servo control system.The experimental results of this model were compared with the simulation results.The average error between the established model and the actual system was 0.005175054(m),which was approximately 2.588%of the total travel length,demonstrating the accuracy of the theoretical model.
基金supported by the Science and Technology Research Innovation Team Project LT2019007 of the Department of Education of Liaoning Provincethe Discipline Innovation Team Project LNTU20TD-02,29 of Liaoning Technical University。
文摘Magnetically coupled resonant technology is a novel method for solving the breakpoint locating of power grounding grid.But the method can only detect breakpoints of a single mesh grounding grid at present.In this paper,a magnetically coupled resonant detection method for four-hole grounding grid breakpoint is proposed.Firstly,the equivalent circuit model of the four mesh grounding grid with two types of breakpoints,namely edge branch and intermediate branch,is established.The input impedance and phase angle of the system are obtained by analyzing the equivalent capacitance and equivalent resistance in the model.Secondly,the magnetically coupled resonant physical process of grounding grid faults is solved via HFSS software.The magnetic field intensity and phase frequency characteristic curves of four mesh holes with different branches and positions of breakpoints and different corrosion degrees are studied,and an experimental system is built to verify the feasibility.The results show that under the condition of grounding grid buried depth of 0.5 m and input frequency of 1~15MHz,and there is an inverse relationship between equivalent capacitance and distortion frequency,the phase angle is positively correlated with the degree of corrosion of grounding grid,and the error of signal distortion frequency can be positioned at 5%.This paper provides some ideas for the application of magnetic coupling grounding grid detection technology.
基金supported by National Magnetic Confined Fusion Energy R&D Program of China(No.2022YFE03030001)National Natural Science Foundation of China(Nos.12275310 and 12175277)+1 种基金the Science Foundation of Institute of Plasma Physics,Chinese Academy of Sciences(No.DSJJ-2021-01)the Collaborative Innovation Program of Hefei Science Center,CAS(No.2021HSCCIP019).
文摘For three-dimensional vector fields,the governing formula of invariant manifolds grown from a hyperbolic cycle is given in cylindrical coordinates.The initial growth directions depend on the Jacobians of Poincarémap on that cycle,for which an evolution formula is deduced to reveal the relationship among Jacobians of different Poincarésections.The evolution formula also applies to cycles in arbitrary finite n-dimensional autonomous continuous-time dynamical systems.Non-Möbiusian/Möbiusian saddle cycles and a dummy X-cycle are constructed analytically as demonstration.A real-world numeric example of analyzing a magnetic field timeslice on EAST is presented.
文摘The demand for electric vehicles has increased over the past few years.Wireless power transfer for electric vehicles provides more flexibility than traditional plug-in charging technology.Charging couplers are critical components in wireless power transfer systems.The thermal effect produced by the magnetic coupler in work will cause the temperature of the device to rise rapidly,affecting the work efficiency,transfer power,operation reliability,and service life.This paper modeled and analyzed each component's temperature distribution characteristics and thermal behavior.Firstly,the magnetic coupler's mutual inductance and magnetic circuit model are established,and the thermal model of the magnetic coupler analyzes the heat generation process.The thermal models of the coupler under three different magnetic core distributions are established,and the temperature rise of each component is obtained.The temperature rise of different parts of the coupler is verified by the temperature rise test structure of the experiment.
基金The National Natural Science Foundation of China(No50576013)
文摘To determine and calculate the stable fluidization zone in a magnetically fluidized bed, the fluidization characteristics of magnetic particles are investigated. Four kinds of magnetic particles with different average diameters, ranging from 231 to 512 μm, are fluidized in the presence of magnetic fields with specified values of the intensity in the range of zero to 7330 A/m, and the particle fluidization curves are plotted. For marking the stable fluidization zone in the curves, the minimum bubbling velocities of particles are measured by the pressure-drop fluctuation. Based on the fluidization curves, the influences of the average particle diameter and magnetic field intensity on the zone are analyzed and discussed. A correlation to determine the stable fluidization zone is derived from the experimental data, using three dimensionless numbers, i. e., the ratio of magnetic potential to gravity potential, the Reynolds number and the Archimedes number. Compared with available data reported, it is shown that the correlation is more simplified to predict relative parameters for the bed operating in the state of stable fluidization under reasonable conditions.
基金This work was supported by the National Natural Science Foundation of China under grant No.50177019by the Education Department of China under grant No.20040142004.
文摘The static and dynamic magnetic controlling characteristics of NiMnGa magnetically controlled shape memory alloy (MSMA) were experimentally studied. The results show that the characteristics of induced strain with respect to the magnetic field are nonlinear with saturation nature, and dependent on the temperature as well as the load applied to the MSMA. The magnetic shape memory effect can be observed only in complete martensite phase at room temperature. The magnetic permeability of MSMA is not constant and reduces with the increment of magnetic field. The relative saturation magnetic permeability of MSMA is about 1.5.
基金Supported by Shanghai Nano Technology Special Program (No.0452nm017).
文摘A magnetically separable photocatalyst TiO2/SiO2/NiFe2O4 (TSN) with a typical ferromagnetic hysteresis was prepared by a liquid catalytic phase transfer method. When the intensity of applied magnetic field weakened to zero, the remnant magnetism of the prepared photocatalyst faded to zero. The photocatalytst can be separated from water when an external magnetic field is added and redispersed into aqueous solution after the external magnetic field is eliminated, that makes the photocatalysts promising for wastewater treatment. Transmission electron microscope (TEM) and X-ray diffractometer (XRD) were used to characterize the structure of the photocatalyst indicating that the magnetic SiOffNiFe204 (SN) particle was compactly enveloped by P-25 titania and Tit2 shell was formed. The magnetic composite showed high photocatalytic activity for the degradation of methyl orange in water. A thin SiO2 layer between NiFe2O4 and TiO2 shell prevented effectively the leakage of charges from TiO2 particles to NiFe2O4, which gave rise to the increase in photocatalytic activity. Moreover, the experiment on recycled use of TSN demonstrated a good repeatability of the photocatalytic activity.
基金Supported by National Natural Science Foundation of China(Major Instrumental Program)No.81127005the Science and Technology Innovation Project of Shaanxi Province,China,No.S2016TNGY0119
文摘AIM To design a miniature magnetically anchored and controlled camera system to reduce the number of trocars which are required for laparoscopy.METHODS The system consists of a miniature magnetically anchored camera with a 30° downward angle, an external magnetically anchored unit, and a vision output device. The camera weighs 12 g, measures Φ10.5 mm × 55 mm and has two magnets, a vision model, a light source, and a metal hexagonal nut. To test the prototype, the camera was inserted through a 12-mm conventional trocar in an ex vivo real liver laparoscopic training system. A trocar-less laparoscopic cholecystectomy was performed 6 times using a 12-mm and a 5-mm conventional trocar. In addition, the same procedure was performed in four canine models.RESULTS Both procedures were successfully performed using only two conventional laparoscopic trocars. The cholecystectomy was completed without any major complication in 42 min(38-45 min) in vitro and in 50 min(45-53 min) using an animal model. This camera was anchored and controlled by an external unit magnetically anchored on the abdominal wall. The camera could generate excellent image. with no instrument collisions.CONCLUSION The camera system we designed provides excellent optics and can be easily maneuvered. The number of conventional trocars is reduced without adding technical difficulties.
基金supported by the Chinese National Natural Science Foundation (Grant No 10675168)Innovation Fund of Graduate School of the National University of Defense Technology of China
文摘An X-band magnetically insulated transmission line oscillator (MILO) is designed and investigated numerically and experimentally for the first time. The X-band MILO is optimized in detail with KARAT code. In simulation, the X-band MILO, driven by a 720 kV, 53 kA electron beam, comes to a nonlinear steady state in 4.0 ns. High-power microwaves (HPM) of TEM mode is generated with an average power of 4.1 GW, a frequency of 9.3 GHz, and power conversion efficiency of 10.870 in durations of 0-40 ns. The device is fabricated according to the simulation results. In experiments, when the voltage is 400 kV and the current is 50 kA, the radiated microwave power reaches about 110 MW and the dominating frequency is 9.7GHz. Because the surfaces of the cathode end and the beam dump are destroyed, the diode voltage cannot increase continuously. However, when the diode voltage is 400 kV, the average power output is obtained to be 700 MW in simulation. The impedance of the device is clearly smaller than the simulation prediction. Moreover, the duration of the microwave pulse is obviously shorter than that of the current pulse. The experimental results are greatly different from the simulation predictions. The preliminary analyses show that the generations of the anode plasma, the cathode flare and the anode flare are the essential cause for the remarkable deviation of the experimental results from the simulation predictions.
文摘A magnetically stabilized fluidized bed (MSB) is a highly efficient filter that takes the advantage of both fluidized beds and fixed beds. This paper presents the research to collect aerosol in airflow with a MSB. The filtering model of MSB is established with its parameters including magnetic Geld intensity, gas superficial velocity, average grain-size, and bed height on the collection efficiency of MSB. The model is verified by experiments.
基金financial support of National Natural Science Fund of China(No. 51172282)Hebei Natural Science Fund of China (No. E2015506011)
文摘FeSiAl magnetically soft alloy hollow microspheres(MSAHMs) were prepared by self-reactive quenching technology based on Fe + Si + AI + KNO_3 reactive systems, in order to obtain absorbents with light weight, low frequency and high efficiency. Firstly, twice-balling adhesive precursor method was used to obtain FeSiAl magnetically soft alloy agglomerate powders. Then agglomerate powders with the mesh number of 150-240, 240-325 and 325-400 were sprayed through the flame field into the quenching water. At last, FeSiAl MSAHMs with coarse(average at 86.97 μm), medium(average at 52.16 μm) and fine particles(average at 31.80 μm) were got. Effect of particle size on the phases and microwave absorption properties in low frequency band was studied by XRD and vector network analyzer. The results show that,Fe_3 Si_(0.7)Al_(0.3) and Fe_3 Si_(0.5)Al_(0.5) appear in the phase components of FeSiAl MSAHMs,which is important to improve the microwave absorption properties in low frequency. In addition, the real part(ε′) and imaginary part(ε″) of complex permittivity, the real part(μ′) and imaginary part(μ″) of complex permeability of FeSiAl MSAHMs all present the trend of fine particles > medium particles > coarse particles. The microwave absorption properties in low frequency are improved with the increasing of particle size, and the absorption peak moves to lower frequency range. The properties of fine particles are the best. Their matching thickness of samples is at 5 mm, and the minimum reflectivity is-43 dB at this thickness. The absorption frequency band lower than-10 dB is 4.6-7.6 GHz with a bandwidth of 3 GHz.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11035005,11475174,and 50876101)the Science Instrument Foundation of the Chinese Academy of Sciences(Grant No.Y201162)
文摘An arc channel tends to shrink due to its conductivity increasing with the increase of temperature. In this study, to generate large area arc plasma, we construct a magnetically rotating arc plasma generator, which mainly consists of a lanthanide tungsten cathode (13 mm in diameter), a concentric cylindrical graphite anode chamber (60 nun in diameter) and a solenoid coil for producing an axial magnet field. By controlling the cold gas flow, the magnetically rotating arc evolves from constricted mode to diffuse mode, which almost fills the whole arc chamber cross section. Results show that the diffuse arc plasma has better uniformity and stability. The formation mechanism of large area arc plasma is discussed in this paper.
基金supported by National Natural Science Foundation of China(No.10905047)
文摘A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/cm. In the paper, the current loss of an MITL made of stainless steel, which is usually used in large pulse power generators, is experimentally studied, and possible mechanisms to explain the current loss of the MITL are analyzed and discussed. From the experimental results, the relationship between loss current density and input current density follows approximately a power law. The loss is also related to the configuration of the MITL.
基金supported by National Natural Science Foundation of China (Nos.50876101,11035005)
文摘Magnetically dispersed arc plasma exhibits typically dispersed uniform arc column as well as diffusive cathode root and diffusive anode root. In this paper magnetically dispersed arc plasma coupled with solid cathode is numerically simulated by the simplified cathode sheath model of LOWKE . The numerical simulation results in argon show that the maximum value of arc root current density on the cathode surface is 3.5×10^7 A/m^2), and the maximum value of energy flux on the cathode surface is 3× 10^7 J/m^2, both values are less than the average values of a contracted arc, respectively.
基金Supported by the National Natural Science Foundation of China (No.20206023) and SIN0PEC (No.X504029).
文摘Axial liquid dispersion was experimentally studied in liquid-solid and gas-liquid-solid magnetically stabilized beds using the ferromagnetic catalyst of SRNA-4 as the solid phase. The effects of operating factors and fluid characters, such as superficial liquid velocity, superficial gas velocity, magnetic field intensity, liquid viscosity and surface tension, on axial dispersion coefficients of liquid were investigated. The dispersion coefficients increased with the increase of superficial liquid velocity and superficial gas velocity, and decreased with the increase of liquid viscosity, liquid surface tension and magnetic field intensity. A correlation equation of Peclet number was obtained for both liquid-solid and gas-liquid-solid magnetically stabilized bed.
基金the National Basic Research Program of China(2009CB724700)the Foundation of Jiangsu Province of China for College Postgraduate Students in Innovation Engineering(CXZZ12_0440)
文摘Magnetically modified palygorskite composites were synthesized with γ-Fe2O3 dispersing on the external surface of clay mineral. The magnetic clay was characterized with Fourier transform infrared, X-ray diffrac- tion, transmission electron microscopy, and vibrating sample magnetometer. Candida sp. 99-125 lipase was immobilized on magnetic palygorskite composites by physical adsorption with enzyme loading of 41.5 mg· g^-1 support and enzyme activity of 2631.6 U· (g support)^-1. The immobilized lipase exhibit better thermal and broader pH stability and excellent reusabilitV compared with free lipase.