General Administration of Quality Supervision,Inspection and Quarantine of P.R.China has approved the following 8 national measuring verification regulations in 2010 and publicize now.
General Administration of Quality Supervision,Inspection and Quarantine of P.R.China has approved the following 11 national measuring verification regulations in 2008 and publicize now.
General Administration of Quality Supervision,Inspection and Quarantine of P.R.China hasapproved the following 24 national measuring verification regulations in 2008 and publicize now.
General Administration of Quality Supervision,Inspection and Quarantine of P.R.China has approved the following 10 national measuring verification regulations in 2008 and publicize now.
The SC200 proton therapy system commissioned by the Hefei CAS Ion Medical and Technical Devices Co.,Ltd.(HFCIM;Hefei,China)and the Joint Institute for Nuclear Research(JINR;Dubna,Russia)has made significant progress.A...The SC200 proton therapy system commissioned by the Hefei CAS Ion Medical and Technical Devices Co.,Ltd.(HFCIM;Hefei,China)and the Joint Institute for Nuclear Research(JINR;Dubna,Russia)has made significant progress.A main radial beam diagnostic system(MRBDS)equipped with a new type of train probe was developed to satisfy the requirements of beam diagnosis.In this paper,the detailed design of the mechanical structure and electronics system of the MRBDS is presented.The electronics system,which includes hardware and software components,was tested and calibrated.The results show that measurement errors can be significantly reduced by the designed calibration procedures.The repeatability of the mechanical structure was also verified,and the experimental results indicate that the unidirectional repeatability of the positioning is better than 0.3 mm.Finally,the MRBDS was used to measure the phase lag of the particles in the beam,and the results showed a high degree of agreement with theoretical calculations,which proved the applicability and high efficiency of the MRBDS.展开更多
Based on measuring the cross-spectrum density of sound pressure between two hydrophones, the facility for underwater sound intensity measurement is investigated and designed. According to the principle of two-hydroph...Based on measuring the cross-spectrum density of sound pressure between two hydrophones, the facility for underwater sound intensity measurement is investigated and designed. According to the principle of two-hydrophone method for intensity measurement, the error analysis is carried out. Given the method of sound intensity measurement calibration for this underwater sound intensity measurement facility, the uncertainty of intensity measurement by this facility is evaluated. It is shown that the analysis and evaluation are agreeable to the experimental results.展开更多
文摘General Administration of Quality Supervision,Inspection and Quarantine of P.R.China has approved the following 8 national measuring verification regulations in 2010 and publicize now.
文摘General Administration of Quality Supervision,Inspection and Quarantine of P.R.China has approved the following 11 national measuring verification regulations in 2008 and publicize now.
文摘General Administration of Quality Supervision,Inspection and Quarantine of P.R.China hasapproved the following 24 national measuring verification regulations in 2008 and publicize now.
文摘General Administration of Quality Supervision,Inspection and Quarantine of P.R.China has approved the following 10 national measuring verification regulations in 2008 and publicize now.
基金This work was supported by the funding of the CN-RU cooperation cyclotron design(No.1604b0602005).
文摘The SC200 proton therapy system commissioned by the Hefei CAS Ion Medical and Technical Devices Co.,Ltd.(HFCIM;Hefei,China)and the Joint Institute for Nuclear Research(JINR;Dubna,Russia)has made significant progress.A main radial beam diagnostic system(MRBDS)equipped with a new type of train probe was developed to satisfy the requirements of beam diagnosis.In this paper,the detailed design of the mechanical structure and electronics system of the MRBDS is presented.The electronics system,which includes hardware and software components,was tested and calibrated.The results show that measurement errors can be significantly reduced by the designed calibration procedures.The repeatability of the mechanical structure was also verified,and the experimental results indicate that the unidirectional repeatability of the positioning is better than 0.3 mm.Finally,the MRBDS was used to measure the phase lag of the particles in the beam,and the results showed a high degree of agreement with theoretical calculations,which proved the applicability and high efficiency of the MRBDS.
文摘Based on measuring the cross-spectrum density of sound pressure between two hydrophones, the facility for underwater sound intensity measurement is investigated and designed. According to the principle of two-hydrophone method for intensity measurement, the error analysis is carried out. Given the method of sound intensity measurement calibration for this underwater sound intensity measurement facility, the uncertainty of intensity measurement by this facility is evaluated. It is shown that the analysis and evaluation are agreeable to the experimental results.