期刊文献+
共找到54篇文章
< 1 2 3 >
每页显示 20 50 100
High-resolution x-ray monochromatic imaging for laser plasma diagnostics based on toroidal crystal 被引量:2
1
作者 司昊轩 董佳钦 +3 位作者 方智恒 蒋励 伊圣振 王占山 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第1期181-186,共6页
Monochromatic x-ray imaging is an essential method for plasma diagnostics related to density information.Large-field high-resolution monochromatic imaging of a He-like iron(Fe XXV)Kαcharacteristic line(6.701 keV)for ... Monochromatic x-ray imaging is an essential method for plasma diagnostics related to density information.Large-field high-resolution monochromatic imaging of a He-like iron(Fe XXV)Kαcharacteristic line(6.701 keV)for laser plasma diagnostics was achieved using a developed toroidal crystal x-ray imager.A high-index crystal orientation Ge(531)wafer with a Bragg angle of 75.37°and the toroidal substrate were selected to obtain sufficient diffraction efficiency and compensate for astigmatism under oblique incidence.A precise offline assembly method of the toroidal crystal imager based on energy substitution was proposed,and a spatial resolution of 3-7μm was obtained by toroidal crystal imaging of a 600 line-pairs/inch Au grid within an object field of view larger than 1.0 mm.The toroidal crystal x-ray imager has been successfully tested via side-on backlight imaging experiments of the sinusoidal modulation target and a 1000 line-pairs/inch Au grid with a linewidth of 5μm using an online alignment method based on dual positioning balls to indicate the target and backlighter.This paper describes the optical design,adjustment method,and experimental results of a toroidal crystal system in a laboratory and laser facility. 展开更多
关键词 laser plasma diagnostics toroidal crystal monochromatic x-ray imaging
下载PDF
Enthalpy Probe Technique for Thermal Plasma Diagnostics 被引量:2
2
作者 冯晓珍 《Plasma Science and Technology》 SCIE EI CAS CSCD 2003年第4期1909-1914,共6页
The measuring principle and experimental results of the enthalpy probe technique for thermal plasma diagnostics are presented. Its calibration and errors are discussed. Typical results are presented for the system ope... The measuring principle and experimental results of the enthalpy probe technique for thermal plasma diagnostics are presented. Its calibration and errors are discussed. Typical results are presented for the system operation in an Ar/H2(5 % H2) plasma arc jet under a reactor chamber pressure of 101.3 kPa. The plasma temperature and velocity profiles are measured. The center temperature and velocity are 6600 K and 850 m/s for plasma power 9 kW at axial location of 17 mm. 展开更多
关键词 probe technique thermal plasma diagnostics
下载PDF
Development and Integration of a Data Acquisition System for SST-1 Phase-1 Plasma Diagnostics 被引量:1
3
作者 Amit K SRIVASTAVA Manika SHARMA +3 位作者 Imran MANSURI Atish SHARMA Tushar RAVAL Subrata PRADHAN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第11期1002-1007,共6页
Long pulse (of the order of 1000 s or more) SST-1 tokamak experiments demand a data acquisition system that is capable of acquiring data from various diagnostics channels without losing useful data (and hence physi... Long pulse (of the order of 1000 s or more) SST-1 tokamak experiments demand a data acquisition system that is capable of acquiring data from various diagnostics channels without losing useful data (and hence physics information) while avoiding unnecessary generation of a large volume data. SST-1 Phase-1 tokamak operation has been envisaged with data acquisition of several essential diagnostics channels. These channels demand data acquisition at a sampling rate ranging from 1 kilo samples per second (KSPS) to 1 mega samples per second (MSPS). Considering the technical characteristics and requirements of the diagnostics, a data acquisition system based on PXI and CAMAC has been developed for SST-1 plasma diagnostics. Both these data acquisition systems are scalable. Present data acquisition needs involving slow plasma diagnostics are catered by the PXI based data acquisition system. On the other hand, CAMAC data acquisition hardware meets all requirements of the SST-1 Phase-1 fast plasma diagnostics channels. A graphical user interface for both data acquisition systems (PXI and CAMAC) has been developed using LabVIEW application development software. The collected data on the local hard disk are directly streaming to the central server through a dedicated network for post-shot data analysis. This paper describes the development and integration of the data acquisition system for SST-1 Phase-1 plasma diagnostics. The integrated testing of the developed data acquisition system has been performed using SST-1 central control and diagnostics signal conditioning units. In the absence of plasma shots, the integrated testing of the data acquisition system for the initial diagnostics of SST-1 Phase-1 operation has been performed with simulated physical signals. The primary engineering objective of this integrated testing is to validate the performance of the developed data acquisition system under simulated conditions close to that of actual tokamak operation. The data acquisition is synchronized with a clock and trigger provided by the central timing system. 展开更多
关键词 SST-1 data acquisition CAMAC PXI plasma diagnostics
下载PDF
The plume diagnostics of 30 cm ion thruster with an advanced plasma diagnostics system 被引量:1
4
作者 Tao CHEN Juntai YANG +1 位作者 Xinwei CHEN Yong ZHAO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第9期38-43,共6页
In order to achieve a better understanding of plume characteristics of LIPS-300 ion thruster,the beam current density,ion energy and electron number density of LIPS-300 ion thruster plume are studied with an Advanced ... In order to achieve a better understanding of plume characteristics of LIPS-300 ion thruster,the beam current density,ion energy and electron number density of LIPS-300 ion thruster plume are studied with an Advanced Plasma Diagnostics System(APDS)which allows for simultaneous in situ measurements of various properties characterizing ion thruster,such as plasma density,plasma potential,plasma temperature and ion beam current densities,ion energy distribution and so on.The results show that the beam current density distribution has a double‘wing'shape.The high energy ions were found in small scan angle,while low energy ions were found in greater scan angle.Electron number density has a similar shape with the beam current density distribution. 展开更多
关键词 electric propulsion ion thruster plasma diagnostics
下载PDF
Progress in Plasma Diagnostics and Physics Experiment 被引量:1
5
《Southwestern Institute of Physics Annual Report》 2006年第1期12-14,共3页
The development of eight new diagnostic systems and the improvement of the laser Thomson scattering system contributed to the experimental campaign on HL-2A in 2006. Besides, the accuracy and flexibility of the molecu... The development of eight new diagnostic systems and the improvement of the laser Thomson scattering system contributed to the experimental campaign on HL-2A in 2006. Besides, the accuracy and flexibility of the molecular beam injection (MBI) system was improved greatly by using the special driver and controller, it is more convenient for studies such as particle transport. In the field of plasma physics experiment, the features of 3-D GAM zonal flows were further studied and some signs of low frequency zonal flows were observed. In the ECRH experiments, the effects of ECRH on sawtooth activities and m/n= 1/1 mode were studied under different plasma discharge conditions. The effect of MBI during ECRH on plasma behavior, such as non-local heat transport, was also studied. 展开更多
关键词 plasma diagnostics MBI ECRH Sawtoothactivities
下载PDF
Online plasma diagnostics of a laser-produced plasma
6
作者 Kai GAO Nasr A M HAFZ +3 位作者 Song LI Mohammad MIRZAIE Guangyu LI Quratul AIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第1期85-89,共5页
In this study,we report a laser interferometry experiment for the online-diagnosing of a laserproduced plasma.The laser pulses generating the plasma are ultra-fast(30 femtoseconds),ultraintense(tens of Terawatt) a... In this study,we report a laser interferometry experiment for the online-diagnosing of a laserproduced plasma.The laser pulses generating the plasma are ultra-fast(30 femtoseconds),ultraintense(tens of Terawatt) and are focused on a helium gas jet to generate relativistic electron beams via the laser wakefield acceleration(LWFA) mechanism.A probe laser beam(λ=800 nm) which is split-off the main beam is used to cross the plasma at the time of arrival of the main pulse,allowing online plasma density diagnostics.The interferometer setup is based on the No Marski method in which we used a Fresnel bi-prism where the probe beam interferes with itself after crossing the plasma medium.A high-dynamic range CCD camera is used to record the interference patterns.Based upon the Abel inversion technique,we obtained a 3D density distribution of the plasma density. 展开更多
关键词 plasma diagnostics probe beam INTERFEROMETRY abel inversion
下载PDF
High-efficiency,high-resolution multiple monochromatic imaging based on a multilayer mirror array for laser–plasma diagnostics of X-ray continuum emission
7
作者 Tongzhou Li Huiyao Du +6 位作者 Zhong Zhang Zhe Zhang Qiushi Huang Shengzhen Yi Zhanshan Wang Wei Wang Jinren Sun 《High Power Laser Science and Engineering》 SCIE CAS 2024年第4期90-96,共7页
The measurement of X-ray continuous emission from laser-driven plasma was achieved through multiple monochromatic imaging utilizing a multilayer mirror array.This methodology was exemplified by the development of an e... The measurement of X-ray continuous emission from laser-driven plasma was achieved through multiple monochromatic imaging utilizing a multilayer mirror array.This methodology was exemplified by the development of an eight-channel X-ray imaging system,capable of operating in the energy range of several ke V with a spatial resolution of approximately3 μm.By integrating this system with a streak camera,the temperature and trajectory of imploding capsules were successfully measured at the kJ-class Shenguang III prototype laser facility.This approach provides a synchronous diagnostic method for the spatial,temporal and spectral analysis of laser-driven plasma,characterized by its high efficiency and resolution. 展开更多
关键词 high resolution multilayer mirror array multiple monochromatic imaging plasma diagnostics X-ray continuum emission
原文传递
Diagnostics of laser-induced plasma on carbon-based polymer material using atomic and molecular emission spectra
8
作者 Jelena PETROVIC Dragan RANKOVIC +5 位作者 Miroslav KUZMANOVIC Jelena SAVOVIC Vasili KIRIS Alena NEVAR Mikhail NEDELKO Nikolai TARASENKO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第4期175-183,共9页
Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based... Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based polymer that is,among other things,interesting as a substrate for laser-induced breakdown spectroscopy analysis of liquid samples.This study aimed to determine the optimal experimental conditions for obtaining neutral and ionized C spectral lines and C2 and CN molecular band emission suitable for spectrochemical purposes.Evaluation of plasma parameters was done using several spectroscopic techniques.Stark profiles of appropriate C ionic lines were used to determine electron number density.The ratio of the integral intensity of ionic-to-atomic C spectral lines was used to determine the ionization temperature.A spectral emission of C2 Swan and CN violet bands system was used to determine the temperature of the colder,peripheral parts of plasma.We critically analyzed the use of molecular emission bands as a tool for plasma diagnostics and suggested methods for possible improvements. 展开更多
关键词 spectroscopy of laser-induced plasma laser-induced breakdown spectroscopy transversely excited atmospheric CO_(2)laser plasma diagnostics atomic and molecular emission spectra TEFLON
下载PDF
High resolution X-ray spherically bent crystal spectrometer for laser-produced plasma diagnostics 被引量:6
9
作者 肖沙里 王洪建 +2 位作者 施军 唐昶环 刘慎业 《Chinese Optics Letters》 SCIE EI CAS CSCD 2009年第1期92-94,共3页
A new high spectral resolution crystal spectrometer is designed to measure very low emissive X-ray spectra of laser-produced plasma in 0.5-0.9 nm range. A large open aperture (30 ×20 (mm)) mica (002) spheri... A new high spectral resolution crystal spectrometer is designed to measure very low emissive X-ray spectra of laser-produced plasma in 0.5-0.9 nm range. A large open aperture (30 ×20 (mm)) mica (002) spherically bent crystal with curvature radius R = 380 mm is used as dispersive and focusing element. The imaging plate is employed to obtain high spectral resolution with effective area of 30 × 80 (mm). The long designed path of the X-ray spectrometer beam is 980 mm from the source to the detector via the crystal. Experiment is carried out at a 20-J laser facility. X-ray spectra in an absolute intensity scale is obtained from Al laserproduced plasmas created by laser energy of 6.78 J. Samples of spectra obtained with spectral resolution of up to E/△E - 1500 are presented. The results clearly show that the device is good to diagnose laser high-density plasmas. 展开更多
关键词 Laser produced plasmas Lasers MICA plasma diagnostics plasmaS Silicate minerals Spectral resolution SPECTROMETERS SPECTROMETRY X ray analysis X ray spectrographs X ray spectrometers
原文传递
A four-channel multilayer KB microscope for high-resolution 8-keV X-ray imaging in laser-plasma diagnostics 被引量:3
10
作者 伊圣振 穆宝忠 +4 位作者 王新 朱京涛 蒋励 王占山 贺鹏飞 《Chinese Optics Letters》 SCIE EI CAS CSCD 2014年第1期79-82,共4页
A four-channel multilayer Kirkpatrick-Baez (KB) microscope is developed for the 8-keV X-ray imaging of experiments on laser inertial confinement fusion (ICF). A periodic multilayer that works at 8 keV and with a g... A four-channel multilayer Kirkpatrick-Baez (KB) microscope is developed for the 8-keV X-ray imaging of experiments on laser inertial confinement fusion (ICF). A periodic multilayer that works at 8 keV and with a grazing incidence angle of 1.0~ is coated on reflective surfaces to achieve a spatial resolution higher than 5μm and an effective solid angle higher than 10-7 sr. A precise assembly is realized by a conical reference cone to couple with an X-ray framing camera. This study provides detailed information on an optical and multilayer design, assembly method, and experimental results with a Cu X-ray tube. The instrument provides a high-resolution and high-throughput X-ray image for backlit or self-emission imaging of laser plasma at Cu Kα line radiation in Shenguang series laser facilities. 展开更多
关键词 Inertial confinement fusion Laser produced plasmas plasma diagnostics plasma interactions X ray analysis
原文传递
Time-resolved multispectral X-ray imaging with multi-channel Kirkpatrick-Baez microscope for plasma diagnostics at Shenguang-II laser facility 被引量:2
11
作者 伊圣振 穆宝忠 +7 位作者 朱京涛 王新 李文斌 王占山 贺鹏飞 王伟 方智恒 傅思祖 《Chinese Optics Letters》 SCIE EI CAS CSCD 2014年第8期99-102,共4页
A time-resolved multispectral X-ray imaging approach with new version of multi-channel Kirkpatrick- Baez (KB) microscope is developed for laser plasma diagnostics at the kilo joule-class Shenguang-II laser facility ... A time-resolved multispectral X-ray imaging approach with new version of multi-channel Kirkpatrick- Baez (KB) microscope is developed for laser plasma diagnostics at the kilo joule-class Shenguang-II laser facility (SG-II). The microscope uses a total external reflection mirror in the sagittal direction and an array of multilayer mirrors in the tangential direction to obtain multiple individual high-resolution, high- throughput, and quasi-monochromatic X-ray images. The time evolution of the imploded target in multiple X-ray energy bands can be acquired when coupled with an X-ray streak camera. The experimental result of the time-resolved 2.5 and 3.0 keV dual-spectral self-emission imaging of the undoped CH shell target on SG-II is given. 展开更多
关键词 Computerized tomography Laser produced plasmas MICROSCOPES Mirrors plasma diagnostics plasma interactions X ray analysis
原文传递
Simulating Microwave Radiation of Pyramidal Horn Antenna for Plasma Diagnostics
12
作者 J.S.Shang 《Communications in Computational Physics》 SCIE 2006年第4期677-700,共24页
Computational simulation of the radiating structure of a microwave from a pyramidal horn has been successfully accomplished.This simulation capability is de-veloped for plasma diagnostics based on a combination of thr... Computational simulation of the radiating structure of a microwave from a pyramidal horn has been successfully accomplished.This simulation capability is de-veloped for plasma diagnostics based on a combination of three-dimensional Maxwell equations in the time domain and the generalized Ohm’s law.The transverse electrical electromagnetic wave of the TE1,0 mode propagating through a plasma medium and transmitting from antenna is simulated by solving these governing equations.Numerical results were obtained for a range of plasma transport properties including electrical con-ductivity,permittivity,and plasma frequency.As a guided microwave passing through plasma of finite thickness,the reflections at the media interfaces exhibit substantial distortion of the electromagnetic field within the thin sheet.In radiating simulation,the edge diffraction at the antenna aperture is consistently captured by numerical so-lutions and reveals significant perturbation to the emitting microwave.The numerical solution reaffirms the observation that the depth of the plasma is a critical parameter for diagnostics measurement. 展开更多
关键词 plasma diagnostics microwave simulation ANTENNA
原文传递
Diagnostics of Argon Inductively Coupled Plasma and Dielectric Barrier Discharge Plasma by Optical Emission Spectroscopy
13
作者 张家良 俞世吉 +1 位作者 马滕才 邓新绿 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第4期883-890,共8页
An experimental setup was built up to carry out radio frequency (RF) inductively coupled plasma (ICP) and dielectric barrier discharge (DBD), and to depict the optical emission spectra (OES) of the discharges. OES fro... An experimental setup was built up to carry out radio frequency (RF) inductively coupled plasma (ICP) and dielectric barrier discharge (DBD), and to depict the optical emission spectra (OES) of the discharges. OES from argon ICP and DBD plasmas in visible and near ultraviolet region were measured. For argon ICP, the higher RF power input (higher than 500 W for our machine), the higher degree of argon plasma ionization. But that doesn't mean a higher mean electron energy. With the increase in the power input, the mean electron energy increases slightly, whereas the density of electron increases apparently On the contrary, argon DBD discharge behaves in the manner of a pulsed DC discharge on optical emission spectroscopy and V-I characteristics. DBD current is composed of a series of pulses equally spaced in temporal domain. The Kinetics of DBD emission strength is mainly governed by the frequency of the current pulse. 展开更多
关键词 In ICP diagnostics of Argon Inductively Coupled plasma and Dielectric Barrier Discharge plasma by Optical Emission Spectroscopy
下载PDF
Ultrafast pulse-dilation framing camera and its application for time-resolved X-ray diagnostic
14
作者 Hou-Zhi Cai Qiu-Yan Luo +10 位作者 Kai-Xuan Lin Xuan Deng Jun-Kai Liu Kai-Zhi Yang Dong Wang Jia-Jie Chen Jia-Heng Wang Jing-Hua Long Li-Hong Niu Yun-Fei Lei Jin-Yuan Liu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期101-114,共14页
An ultrafast framing camera with a pulse-dilation device,a microchannel plate(MCP)imager,and an electronic imaging system were reported.The camera achieved a temporal resolution of 10 ps by using a pulse-dilation devi... An ultrafast framing camera with a pulse-dilation device,a microchannel plate(MCP)imager,and an electronic imaging system were reported.The camera achieved a temporal resolution of 10 ps by using a pulse-dilation device and gated MCP imager,and a spatial resolution of 100μm by using an electronic imaging system comprising combined magnetic lenses.The spatial resolution characteristics of the camera were studied both theoretically and experimentally.The results showed that the camera with combined magnetic lenses reduced the field curvature and acquired a larger working area.A working area with a diameter of 53 mm was created by applying four magnetic lenses to the camera.Furthermore,the camera was used to detect the X-rays produced by the laser-targeting device.The diagnostic results indicated that the width of the X-ray pulse was approximately 18 ps. 展开更多
关键词 Inertial confinement fusion plasma diagnostics Framing camera Combined lenses Pulse-dilation
下载PDF
Optimized online filter stack spectrometer for ultrashort X-ray pulses
15
作者 Jia-Xing Wen Ge Ma +17 位作者 Ming-Hai Yu Yu-Chi Wu Yong-Hong Yan Shao-Yi Wang Huai-Zhong Gao Lu-Shan Wang Yu-Gang Zhou Qiang Li Yue Yang Fang Tan Xiao-Hui Zhang Jie Zhang Wen-Bo Mo Jing-Qin Su Wei-Min Zhou Yu-Qiu Gu Ming Zeng Zong-Qing Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第5期85-98,共14页
Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for c... Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for characterizing electron dynamics and applications.In this study,scintillators and silicon PIN(P-type–intrinsic-N-type semiconductor)diodes were used to construct a wideband online filter stack spectrometer.The X-ray sensor and filter arrangement was optimized using a genetic algorithm to minimize the condition number of the response matrix.Consequently,the unfolding error was significantly reduced based on numerical experiments.The detector responses were quantitatively calibrated by irradiating the scintillator and PIN diode with various nuclides and comparing the measuredγ-ray peaks.A prototype 15-channel spectrometer was developed by integrating an X-ray detector with front-and back-end electronics.The prototype spectrometer could record X-ray pulse signals at a repetition rate of 1 kHz.Furthermore,an optimized spectrometer was employed to record the real-time spectra of laser-driven bremsstrahlung sources.This optimized spectrometer offers a compact solution for spectrum diagnostics of ultrashort X-ray pulses,exhibiting improved accuracy in terms of spectrum measurements and repetition rates,and could be widely used in next-generation high-repetition-rate high-power laser facilities. 展开更多
关键词 Filter stack spectrometer Laser plasma diagnostics X-ray diagnostics Scintillator PIN diode
下载PDF
Polarimeter–interferometer diagnostic using terahertz solid-state sources for fluctuation measurements on Keda Torus e Xperiment(KTX)
16
作者 汪兴康 毛文哲 +17 位作者 谢锦林 兰涛 李弘 刘阿娣 周楚 温晓辉 卫子安 吴捷 陈晨 刘东宽 饶贤昊 蔡虎 邬佳仁 邓鹏 刘海庆 丁卫星 庄革 刘万东 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期61-65,共5页
A multi-channel polarimeter-interferometer has been developed on the Keda Torus eXperiment(KTX)for the study of equilibrium dynamics and internal magnetic fluctuations.A three-wave technique based on terahertz solid-s... A multi-channel polarimeter-interferometer has been developed on the Keda Torus eXperiment(KTX)for the study of equilibrium dynamics and internal magnetic fluctuations.A three-wave technique based on terahertz solid-state sources(-650 GHz)is applied for simultaneous measurements of electron density and Faraday rotation angle.The output power of the microwave source is 2 mW.Faraday rotation effect using a rotating wave plate is tested with phase noise less than 0.8°,and the density phase noise is less than 0.9°.Measurement of Faraday rotation angle and density for discharges on KTX have demonstrated high sensitivity to internal MHD activities. 展开更多
关键词 plasma diagnostics INTERFEROMETRY TERAHERTZ POLARIMETER
下载PDF
First results of CO_(2) dispersion interferometer on EAST tokamak
17
作者 刘郁阳 李维明 +7 位作者 姚远 张耀 张家敏 连辉 洪博 王守信 揭银先 刘海庆 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期76-82,共7页
A dispersion interferometer(DI)has been installed and operates on the Experimental Advanced Superconducting Tokamak(EAST).This DI system utilizes a continuous-wave 9.3μm CO_(2)laser source to measure line-averaged el... A dispersion interferometer(DI)has been installed and operates on the Experimental Advanced Superconducting Tokamak(EAST).This DI system utilizes a continuous-wave 9.3μm CO_(2)laser source to measure line-averaged electron densities accurately.In contrast to conventional interferometers,the DI does not require substantial vibration isolations or compensating systems to reduce the impact of vibrations in the optical path.It also employs a ratio of modulation amplitudes,ensuring it remains immune to the variations in detected intensities.Without a variation compensation system,the DI system on EAST reaches a density resolution of less than1.8×10^(-2)πrad and a temporal resolution of 20μs.The measurements made by the POlarimeterINTerferometer(POINT)system and the far-infrared hydrogen cyanide(HCN)interferometer are remarkably consistent with the DI’s results.The possibility of fringe jumps and the impact of refraction in high-density discharge can be significantly decreased using a shorter wavelength laser source.A rapid density change of 3×10^(19)m^(-3)during 0.15 s has been measured accurately in shot No.114755 of EAST.Additionally,the DI system demonstrates dependability and stability under 305 s long-pulse discharges in shot No.122054. 展开更多
关键词 dispersion interferometer(DI) electron density plasma diagnostics Experimental Advanced Superconducting Tokamak(EAST)
下载PDF
Diagnosis of Unmagnetized Plasma Electron Number Density and Electron-neutral Collision Frequency by Using Microwave 被引量:5
18
作者 袁忠才 时家明 许波 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第6期3137-3138,共2页
The plasma diagnostic method using the transmission attenuation of microwaves at double frequencies (PDMUTAMDF) indicates that the frequency and the electron-neutral collision frequency of the plasma can be deduced ... The plasma diagnostic method using the transmission attenuation of microwaves at double frequencies (PDMUTAMDF) indicates that the frequency and the electron-neutral collision frequency of the plasma can be deduced by utilizing the transmission attenuation of microwaves at two neighboring frequencies in a non-magnetized plasma. Then the electron density can be obtained from the plasma frequency. The PDMUTAMDF is a simple method to diagnose the plasma indirectly. In this paper, the interaction of electromagnetic waves and the plasma is analyzed. Then, based on the attenuation and the phase shift of a microwave in the plasma, the principle of the PDMUTAMDF is presented. With the diagnostic method, the spatially mean electron density and electron collision frequency of the plasma can be obtained. This method is suitable for the elementary diagnosis of the atmospheric-pressure plasma. 展开更多
关键词 plasma diagnostics microwaves ATTENUATION
下载PDF
A comparison among optical emission spectroscopic methods of determining electron temperature in low pressure argon plasmas 被引量:3
19
作者 牛田野 曹金祥 +4 位作者 刘磊 刘金英 王艳 王亮 吕铀 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第9期2757-2763,共7页
In this article, four kinds of optical emission spectroscopic methods of determining electron temperature are used to investigate the relationship between electron temperature and pressure in the cylindrical plasmas o... In this article, four kinds of optical emission spectroscopic methods of determining electron temperature are used to investigate the relationship between electron temperature and pressure in the cylindrical plasmas of dc glow discharges at low pressures in laboratory by measuring the relative intensities of ArI lines at various pressures. These methods are developed respectively on the basis of the Fermi-Dirac model, corona model, and two kinds of electron collision cross section models according to the kinetic analysis. Their theoretical bases and the conditions to which they are applicable are reviewed, and their calculation results and fitting errors are compared with each other. The investigation has indicated that the electron temperatures obtained by the four methods become consistent with each other when the pressure increases in the low pressure argon plasmas. 展开更多
关键词 plasma diagnostics gas discharge optic emission spectroscopy electron temperature
下载PDF
Investigation of Atmospheric Pressure Plasma Discharge and Its Application to Surface Modification of Blood-Filtering Material 被引量:2
20
作者 唐晓亮 冯贤平 +2 位作者 邱高 闫永辉 施芸城 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第5期2463-2466,共4页
Melt-blown polybutylene terephthalate (PBT) nonwoven materials treated by usingplasma is regarded as one of the excellent materials to filter white blood cells (WBC) from blood.In this paper, dielectric barrier discha... Melt-blown polybutylene terephthalate (PBT) nonwoven materials treated by usingplasma is regarded as one of the excellent materials to filter white blood cells (WBC) from blood.In this paper, dielectric barrier discharge (DBD) plasma source at an improved quasi-stable at-mospheric pressure is achieved when discharge voltage, discharge current, and gap between theelectrodes are carefully controlled. This plasma source has been used to modify the surface ofPBT melt-blown nonwoven materials. Experimental results indicate that both the wettablity andpermeation of treated PBT melt-blown nonwoven materials are greatly improved. 展开更多
关键词 dielectric barrier discharge plasma diagnostics PBT melt-blown nonwoven material
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部