Driving pressure(ΔP)is a core therapeutic component of mechanical ventilation(MV).Varying levels ofΔP have been employed during MV depending on the type of underlying pathology and severity of injury.However,ΔP lev...Driving pressure(ΔP)is a core therapeutic component of mechanical ventilation(MV).Varying levels ofΔP have been employed during MV depending on the type of underlying pathology and severity of injury.However,ΔP levels have also been shown to closely impact hard endpoints such as mortality.Considering this,conducting an in-depth review ofΔP as a unique,outcome-impacting therapeutic modality is extremely important.There is a need to understand the subtleties involved in making sureΔP levels are optimized to enhance outcomes and minimize harm.We performed this narrative review to further explore the various uses ofΔP,the different parameters that can affect its use,and how outcomes vary in different patient populations at different pressure levels.To better utilizeΔP in MV-requiring patients,additional large-scale clinical studies are needed.展开更多
BACKGROUND Neonatal respiratory distress syndrome(NRDS)is one of the most common diseases in neonatal intensive care units,with an incidence rate of about 7%among infants.Additionally,it is a leading cause of neonatal...BACKGROUND Neonatal respiratory distress syndrome(NRDS)is one of the most common diseases in neonatal intensive care units,with an incidence rate of about 7%among infants.Additionally,it is a leading cause of neonatal death in hospitals in China.The main mechanism of the disease is hypoxemia and hypercapnia caused by lack of surfactant AIM To explore the effect of pulmonary surfactant(PS)combined with noninvasive positive pressure ventilation on keratin-14(KRT-14)and endothelin-1(ET-1)levels in peripheral blood and the effectiveness in treating NRDS.METHODS Altogether 137 neonates with respiratory distress syndrome treated in our hospital from April 2019 to July 2021 were included.Of these,64 control cases were treated with noninvasive positive pressure ventilation and 73 observation cases were treated with PS combined with noninvasive positive pressure ventilation.The expression of KRT-14 and ET-1 in the two groups was compared.The deaths,complications,and PaO_(2),PaCO_(2),and PaO_(2)/FiO_(2)blood gas indexes in the two groups were compared.Receiver operating characteristic curve(ROC)analysis was used to determine the diagnostic value of KRT-14 and ET-1 in the treatment of NRDS.RESULTS The observation group had a significantly higher effectiveness rate than the control group.There was no significant difference between the two groups in terms of neonatal mortality and adverse reactions,such as bronchial dysplasia,cyanosis,and shortness of breath.After treatment,the levels of PaO_(2)and PaO_(2)/FiO_(2)in both groups were significantly higher than before treatment,while the level of PaCO_(2)was significantly lower.After treatment,the observation group had significantly higher levels of PaO_(2)and PaO_(2)/FiO_(2)than the control group,while PaCO_(2)was notably lower in the observation group.After treatment,the KRT-14 and ET-1 levels in both groups were significantly decreased compared with the pre-treatment levels.The observation group had a reduction of KRT-14 and ET-1 levels than the control group.ROC curve analysis showed that the area under the curve(AUC)of KRT-14 was 0.791,and the AUC of ET-1 was 0.816.CONCLUSION Combining PS with noninvasive positive pressure ventilation significantly improved the effectiveness of NRDS therapy.KRT-14 and ET-1 levels may have potential as therapeutic and diagnostic indicators.展开更多
Objective:This study aims to evaluate the clinical efficacy of non-invasive positive pressure ventilation(NIPPV)in patients with severe bronchial asthma combined with respiratory failure.Methods:90 patients with sever...Objective:This study aims to evaluate the clinical efficacy of non-invasive positive pressure ventilation(NIPPV)in patients with severe bronchial asthma combined with respiratory failure.Methods:90 patients with severe bronchial asthma combined with respiratory failure between September 2022 and December 2023 were selected for the study and randomly divided into the experimental group(NIPPV-assisted treatment)and the control group.The differences between the two groups were compared in terms of total effective rate of treatment,days of clinical symptom disappearance,days of hospitalization,lung function indexes,incidence of adverse reactions,and quality of life.Results:Patients in the experimental group had a significantly higher total effective rate of treatment(97.78%)than the control group(75.56%).In terms of pulmonary function indexes,patients in the experimental group showed significant improvement after treatment,especially the increase in forced expiratory volume and forced vital capacity,while these improvements were not as obvious in the control group.In addition,the incidence of adverse reactions was significantly lower in the experimental group than in the control group,suggesting that the application of NIPPV is relatively safe.Quality of life assessment also showed that patients in the experimental group had significantly better quality of life than the control group after treatment.Conclusion:This study demonstrated the effectiveness of NIPPV as an adjunctive treatment for severe bronchial asthma combined with respiratory failure.NIPPV can improve lung function,reduce the incidence of adverse effects,increase the overall effectiveness of the treatment,and contribute to the improvement of patients'quality of life.Therefore,NIPPV should be regarded as an effective and safe treatment in clinical management,especially in patients with severe bronchial asthma combined with respiratory failure,where its application has potential clinical significance.展开更多
When better fuel-air mixing in the combustion chamber or a reduction in base drag are required in vehicles,rockets,and aeroplanes,the base pressure control is activated.Controlling the base pressure and drag is necess...When better fuel-air mixing in the combustion chamber or a reduction in base drag are required in vehicles,rockets,and aeroplanes,the base pressure control is activated.Controlling the base pressure and drag is necessary in both scenarios.In this work,semi-circular ribs with varying diameters(2,4,and 6 mm)positioned at six distinct positions(0.5D,1D,1.5D,2D,3D,and 4D)inside a square duct with a side of 15 mm are proposed as an efficient way to apply the passive control technique.In-depth research is done on optimising rib size for various rib sites.According to this study,the base pressure rises as rib height increases.Furthermore,the optimal location for the semi-circular ribs with a diameter of 2 mm is at 0.5D.The 1D location appears to be optimal for the 4 mm size as well.For the 6 mm size,however,the 4D position fills this function.展开更多
Introduction: High blood pressure is defined as blood pressure greater than or equal to 140 mm Hg for systolic and or 90 mm Hg for diastolic. It constitutes a major public health problem, the leading chronic disease i...Introduction: High blood pressure is defined as blood pressure greater than or equal to 140 mm Hg for systolic and or 90 mm Hg for diastolic. It constitutes a major public health problem, the leading chronic disease in the world. The objective was to determine the prevalence, treatment rate and control of hypertension. Methods: This was a cross-sectional and descriptive study which took place over a period of 6 months in a hospital environment and in the general population. Results: Of the 1000 participants, 637 had hypertension, giving a prevalence of 63.70% with a female predominance. Thirty-three percent (33%) were unaware of their high blood pressure. The age group 60 and more was the most represented (44%). A proportion of 33 and 23.20 were overweight and obese participants, respectively. Male subjects were more overweight than female, unlike obesity which was more common among female subjects. Sixty-two percent (62%) of hypertensives were treated, of whom 44% were non-compliant. The excessively high cost and consumption of medications as needed were the main factors in therapeutic non-compliance. Twenty-two percent (22%) of all hypertensive patients and 35% of treated hypertensive patients were controlled. Women were more treated but less observant and less controlled than men. Therapeutic coverage and combination therapy rates were lower in rural areas. Hypertensives who had a high level of education were better treated and controlled than those who had no level. Conclusion: High blood pressure remains a real public health problem in Mali. It is more common in people aged 60 and over and in females. One in three hypertensives were unaware of their hypertension. The majority received antihypertensive treatments, but only a minority of them had their hypertension controlled.展开更多
Objective: The association hypertension and diabetes is important. The two pathologies may influence each other. The aim was to study the correlation between glycemic control and blood pressure control and to determin...Objective: The association hypertension and diabetes is important. The two pathologies may influence each other. The aim was to study the correlation between glycemic control and blood pressure control and to determine the factors associated with blood pressure control. Methodology: This was a descriptive cross-sectional study with an analytical focus over 7 months. Patients were recruited as outpatients and all underwent ambulatory blood pressure measure, glycated hemoglobin and creatinine measurements, and assessment of compliance with treatment. Results: During this period 116 patients were collected. The predominance was female 69%. The mean age of the patients was 62 ± 7 years with a peak between 60 and 70 years. The average age of hypertension was 12 years and that of diabetes 6 1/2 years. The most frequently associated cardiovascular risk factor was a sedentary lifestyle (71.5%) after age. 57.8% of patients were not controlled at the office, with a predominance of systolic hypertension (58.2%). 61.6% of patients were controlled by ambulatory blood pressure measure, a rate of 47.8% of white coat hypertension. Glycemic control was observed in 42.2% of cases and 87% of patients had good renal function (glomerular filter rate ≥ 60 ml/mn). Therapeutic compliance was good in 53.4% of cases and dual therapy was the most used therapeutic modality 44.8% (52 patients) followed by triple therapy. The factors associated with poor blood pressure control were glycemic imbalance, non-compliance and monotherapy. Dual therapy had a protective effect. Conclusion: The association of hypertension and type 2 diabetes is frequent. The risk of occurrence increases with age. Ambulatory blood pressure measure is the best method to assess blood pressure control. Optimization of blood pressure control should also include optimization of glycemic control.展开更多
Nuclear power plants exhibit non-linear and time-variable dynamics.Therefore,designing a control system that sets the reactor power and forces it to follow the desired load is complicated.A supercritical water reactor...Nuclear power plants exhibit non-linear and time-variable dynamics.Therefore,designing a control system that sets the reactor power and forces it to follow the desired load is complicated.A supercritical water reactor(SCWR)is a fourth-generation conceptual reactor.In an SCWR,the non-linear dynamics of the reactor require a controller capable of control-ling the nonlinearities.In this study,a pressure-tube-type SCWR was controlled during reactor power maneuvering with a higher order sliding mode,and the reactor outgoing steam temperature and pressure were controlled simultaneously.In an SCWR,the temperature,pressure,and power must be maintained at a setpoint(desired value)during power maneuvering.Reactor point kinetics equations with three groups of delayed neutrons were used in the simulation.Higher-order and classic sliding mode controllers were separately manufactured to control the plant and were compared with the PI controllers speci-fied in previous studies.The controlled parameters were reactor power,steam temperature,and pressure.Notably,for these parameters,the PI controller had certain instabilities in the presence of disturbances.The classic sliding mode controller had a higher accuracy and stability;however its main drawback was the chattering phenomenon.HOSMC was highly accurate and stable and had a small computational cost.In reality,it followed the desired values without oscillations and chattering.展开更多
Objectives: To assess respiratory elastance and resistive properties in patients with autoimmune liver disorders using the passive relaxation expiration technique and compare findings to a group of patients with non-a...Objectives: To assess respiratory elastance and resistive properties in patients with autoimmune liver disorders using the passive relaxation expiration technique and compare findings to a group of patients with non-autoimmune liver disease and control subjects. These findings were then related to control of ventilation and gas exchange. A secondary objective was to assess respiratory muscle strength and gas exchange and their relation to respiratory mechanics. Methods: Measurements included respiratory elastance and resistance using the passive relaxation method. Pulmonary function, gas exchange and control of ventilation were assessed using standard methods. Results: a) Compared to control subjects, Ers in patients with liver disease was on average 50% greater than in controls;b) mean respiratory resistance, expressed as the respiratory constants, K<sub>1</sub> and K<sub>2</sub> in the Rohrer relationship, Pao/V’ = K<sub>1</sub> + K<sub>2</sub>V’, was not different from control resistance;c) mean maximal inspiratory and maximal expiratory pressures averaged 36% and 55% of their respective control values;d) inspiratory occlusion pressure in 0.1 sec (P<sub>0.1</sub>) was increased and negatively associated with FVC;and e) increases in P<sub>0.1</sub>, mean inspiratory flow (Vt/Ti) and presence of respiratory alkalosis confirmed the increase in ventilatory drive. Despite inspiratory muscle weakness in patients, P<sub>0.1</sub>/Pimax averaged 5-fold higher than in control subjects. Conclusions: Despite inspiratory muscle weakness and a V’<sub>E</sub> similar to that in normal subjects, central drive is increased in patients with chronic liver disease. The increase in ventilatory drive is related to smaller lung volumes and weakly associated with increase in respiratory elastance. Findings confirm that P<sub>0.1</sub> is a reliable measure of central drive and is an approach that can be used in the evaluation of control of ventilation in patients with chronic liver disease.展开更多
Based on the principle of transient perturbation analysis,in this paper,a method to objectively determine the weather pattern formed by sea fog is provided.On the basis of the classification results,the circulation si...Based on the principle of transient perturbation analysis,in this paper,a method to objectively determine the weather pattern formed by sea fog is provided.On the basis of the classification results,the circulation situation,divergence and vertical velocity field,and the vertical profile of temperature and humidity are synthesized and analyzed.The basic characteristics of the circulation and physical field of sea fog under low pressure control(L type sea fog)are obtained,and the results are compared with the sea fog under the control of high pressure(H type sea fog):a)L type sea fogs potential height anomaly disturbance is mainly manifested in the low layer,and its average value is-65.66 gpm,gradually weakening upward;b)L type sea fogs inversion structure is weaker than H type sea fogs when it occurs,the fog layer is thicker and the high relative humidity level is high over the fog layer,while the H type sea fogs fog layer has a relatively obvious dry layer;c)L sea fog has three layers of structure at the vertical direction.The first layer 1000-950 hPa is convergence accompanied by weak rise and subsidence,the second layer 950-850 hPa is divergence accompanied by weak subsidence,and the third layer 850 to 500hPa is gradually strengthened.While there are two layer structures of the H type sea fog.1000 hPa is divergence accompanied by weak rising and sinking movement,950-500 hPa is a uniform subsidence movement.d)Probability density statistical analysis further quantified the vertical movement of L and H type sea fog and the distribution of relative humidity in each layer.These conclusions provide an important reference for forecasting the sea fog in the northwest of the Yellow Sea under the condition of low pressure circulation in summer.展开更多
A pressure controlled mechanical ventilator with an automatic secretion clearance function can improve secretion clearance safely and efficiently.Studies on secretion clearance by pressure controlled systems show that...A pressure controlled mechanical ventilator with an automatic secretion clearance function can improve secretion clearance safely and efficiently.Studies on secretion clearance by pressure controlled systems show that these are suited for clinical applications.However,these studies are based on a single lung electric model and neglect the coupling between the two lungs.The research methods applied are too complex for the analysis of a multi-parameter system.In order to understand the functioning of the human respiratory system,this paper develops a dimensionless mathematical model of doublelung mechanical ventilation system with a secretion clearance function.An experiment is designed to verify the mathematical model through comparison of dimensionless experimental data and dimensionless simulation data.Finally,the coupling between the two lungs is studied,and an orthogonal experiment designed to identify the impact of each parameter on the system.展开更多
A mathematical model of mechanical ventilator describes its behavior during artificial ventilation. This paper purposes to create and simulate Mathematical Model (MM) of Pressure Controlled Ventilator (PCV) signal. Th...A mathematical model of mechanical ventilator describes its behavior during artificial ventilation. This paper purposes to create and simulate Mathematical Model (MM) of Pressure Controlled Ventilator (PCV) signal. This MM represents the respiratory activities and an important controlled parameter during mechanical ventilation—Positive End Expiration Pressure (PEEP). The MM is expressed and modelled using periodic functions with inequalities to control the beginning of inspiration and expiration durations. The created MM of PCV signal is combined with an existing multi compartmental model of respiratory system that is modified and developed in the internal parameters—compliances (C) to test created MM. The created MM and model of respiratory system are constructed and simulated using Simulink package in MATLAB platform. The obtained simulator of mechnical ventilation system could potentially represent the pressure signal of PVC as a complete respiratory cycle and continuance waveform. This simulator is also able to reflect a respiratory mechanic by changing some input variables such as inspiration pressure (IP), PEEP and C, which are monitored in volume, flow, pressure and PV loop waveforms. The obtained simulator has provided a simple environment for testing and monitoring PCV signal and other parameters (volume, flow and dynamic compliance) during artificial ventilation. Furthermore, the simulator may be used for studying in the laboratory and training ventilator’s operators.展开更多
The present paper describes the theoretical treatment performed for the geometrical optimization of advanced and improved-shape waveforms as airways pressure excitation for controlled breathings in dual-controlled ven...The present paper describes the theoretical treatment performed for the geometrical optimization of advanced and improved-shape waveforms as airways pressure excitation for controlled breathings in dual-controlled ventilation applied to anaesthetized or severe brain injured patients, the respiratory mechanics of which can be assumed linear. Advanced means insensitive to patient breathing activity as well as to ventilator settings while improved-shape intends in comparison to conventional square waveform for a progressive approaching towards physiological transpulmonary pressure and respiratory airflow waveforms. Such functional features along with the best ventilation control for the specific therapeutic requirements of each patient can be achieved through the implementation of both diagnostic and compensation procedures effectively carried out by the Advance Lung Ventilation System (ALVS) already successfully tested for square waveform as airways pressure excitation. Triangular and trapezoidal waveforms have been considered as airways pressure excitation. The results shows that the latter fits completely the requirements for a physiological pattern of endoalveolar pressure and respiratory airflow waveforms, while the former exhibits a lower physiological behaviour but it is anyhow periodically recommended for performing adequately the powerful diagnostic procedure.展开更多
Objective:The purpose of the study was to assess the clinical efficacy and safety of a combined perfusion suction platform with pressure feedback control function and an ureteroscopic suction sheath that can measure t...Objective:The purpose of the study was to assess the clinical efficacy and safety of a combined perfusion suction platform with pressure feedback control function and an ureteroscopic suction sheath that can measure the ureteropelvic pressure in implementing lithotripsies.Methods:Fifty-two patients who underwent lithotripsy under intelligent monitoring of ureteral intraluminal pressure from June 2016 to January 2018 were retrospectively recruited.The inclusion standard was stone diameter>1.5 cm but<2.5 cm.After the 12/14 Fr suction sheath was placed,manometer interface and suction interface of the sheath were connected to the platform via the pressure sensor and suction tube,respectively.The ureteroscope was connected to the platform perfusion pump,and the crushed stones were aspirated out under negative pressure.Results:According to the location of the stone,21(40.4%)cases were classified as upper ureteral stones,19(36.5%)were midureteral stones,and 12(23.1%)were lower ureteral stones.Forty-seven patients underwent successful primary sheath placement and lithotripsy with a mean operative time of 34.5(standard deviation 18.3)min.Retrograde stone migration did not occur.There were eight patients with hematuria postoperatively.Serious complication was 1.9% with one case of ureteral perforation.Stone clearance was 95.7% at Day 1e2 postoperatively,and 100% at Day 30 postoperatively.Conclusion:Ureteroscopic lithotripsy with intelligent pressure control using our device improved the efficiency of the lithotripsy and rate of stone clearance.The safety of the operation can be ensured.It is worth popularization and application in clinical practice.展开更多
In-situ pressure-preserved coring(IPP-Coring)is considered to be the most reliable and efficient method for the identification of the scale of oil and gas resources.During IPP-Coring,because the rotation behavior of t...In-situ pressure-preserved coring(IPP-Coring)is considered to be the most reliable and efficient method for the identification of the scale of oil and gas resources.During IPP-Coring,because the rotation behavior of the pressure controller valve cover in different medium environments is unclear,interference between the valve cover and inner pipe may occur and negatively affect the IPP-Coring success rate.To address this issue,we conducted a series of indoor experiments employing a high-speed camera to gain greater insights into the valve cover rotation behavior in different medium environments,e.g.,air,water,and simulated drilling fluids.The results indicated that the variation in the valve cover rotation angle in the air and fluid environments can be described by a one-phase exponential decay function with a constant time parameter and by biphasic dose response function,respectively.The rotation behavior in the fluid environments exhibited distinct elastic and gravitational acceleration zones.In the fluid environments,the density clearly impacted the valve cover closing time and rotation behavior,whereas the effect of viscosity was very slight.This can be attributed to the negligible influence of the fluid viscosity on the drag coefficient found in this study;meanwhile,the density can increase the buoyancy and the time period during which the valve cover experienced a high drag coefficient.Considering these results,control schemes for the valve cover rotation behavior during IPP-Coring were proposed for different layers and geological conditions in which the different drilling fluids should be used,e.g.,the use of a high-density valve cover in high-pore pressure layers.展开更多
The operating room is a unique environment where surgery exposes patients to non-physiological changes that can compromise lung mechanics.Therefore,raising clinicians’awareness of the potential risk of ventilator-ind...The operating room is a unique environment where surgery exposes patients to non-physiological changes that can compromise lung mechanics.Therefore,raising clinicians’awareness of the potential risk of ventilator-induced lung injury(VILI)is mandatory.Driving pressure is a useful tool for reducing lung complications in patients with acute respiratory distress syndrome and those undergoing elective surgery.Driving pressure has been most extensively studied in the context of single-lung ventilation during thoracic surgery.However,the awareness of association of VILI risk and patient positioning(prone,beach-chair,parkbench)and type of surgery must be raised.展开更多
Objective Current clinical evidence on the effects of home blood pressure telemonitoring(HBPT)on improving blood pressure control comes entirely from developed countries.Thus,we performed this randomized controlled tr...Objective Current clinical evidence on the effects of home blood pressure telemonitoring(HBPT)on improving blood pressure control comes entirely from developed countries.Thus,we performed this randomized controlled trial to evaluate whether HBPT plus support(patient education and clinician remote hypertension management)improves blood pressure control more than usual care(UC)in the Chinese population.Methods This single-center,randomized controlled study was conducted in Beijing,China.Patients aged 30-75 years were eligible for enrolment if they had blood pressure[systolic(SBP)≥140 mmHg and/or diastolic(DBP)≥90 mmHg;or SBP≥130 mmHg and/or DBP≥80 mmHg with diabetes].We recruited 190 patients randomized to either the HBPT or the UC groups for 12 weeks.The primary endpoints were blood pressure reduction and the proportion of patients achieving the target blood pressure.Results Totally,172 patients completed the study,the HBPT plus support group(n=84),and the UC group(n=88).Patients in the plus support group showed a greater reduction in mean ambulatory blood pressure than those in the UC group.The plus support group had a significantly higher proportion of patients who achieved the target blood pressure and maintained a dipper blood pressure pattern at the12th week of follow-up.Additionally,the patients in the plus support group showed lower blood pressure variability and higher drug adherence than those in the UC group.Conclusion HBPT plus additional support results in greater blood pressure reduction,better blood pressure control,a higher proportion of dipper blood pressure patterns,lower blood pressure variability,and higher drug adherence than UC.The development of telemedicine may be the cornerstone of hypertension management in primary care.展开更多
Mechanical ventilation(MV)is an important strategy for improving the survival of patients with respiratory failure.However,MV is associated with aggravation of lung injury,with ventilator-induced lung injury(VILI)beco...Mechanical ventilation(MV)is an important strategy for improving the survival of patients with respiratory failure.However,MV is associated with aggravation of lung injury,with ventilator-induced lung injury(VILI)becoming a major concern.Thus,ventilation protection strategies have been developed to minimize complications from MV,with the goal of relieving excessive breathing workload,improving gas exchange,and minimizing VILI.By opting for lower tidal volumes,clinicians seek to strike a balance between providing adequate ventilation to support gas exchange and preventing overdistension of the alveoli,which can contribute to lung injury.Additionally,other factors play a role in optimizing lung protection during MV,including adequate positive end-expiratory pressure levels,to maintain alveolar recruitment and prevent atelectasis as well as careful consideration of plateau pressures to avoid excessive stress on the lung parenchyma.展开更多
Background: Noninvasive ventilation (NIV) is an important therapeutic modality for the treatment of acute respiratory failure (ARF). In this review, we critically analyze randomized controlled trials on the most used ...Background: Noninvasive ventilation (NIV) is an important therapeutic modality for the treatment of acute respiratory failure (ARF). In this review, we critically analyze randomized controlled trials on the most used NIV interfaces in the treatments of ARF. Methods: The searches were conducted in the Medline, Lilacs, PubMed, Cochrane, and Pedro databases from June to November 2021. The inclusion criteria were Randomized clinical trials (RCTs) published from 2016 to 2021 in Portuguese, Spanish, or English and involving adults (aged ≥ 18 years). The eligibility criteria for article selection were based on the PICO strategy: Population—Adults with ARF;Intervention—NIV Therapy;Comparison—Conventional oxygen therapy, high-flow nasal cannula (HFNC) oxygen therapy, or NIV;Outcome—improvement in ARF. The search for articles and the implementation of the inclusion criteria were independently conducted by two researchers. Results: Seven scientific articles involving 574 adults with ARF due to various causes, such as chest trauma, decompensated heart failure, coronavirus disease 2019 (COVID-19), and postoperative period, among others, were included. The interfaces cited in the studies included an oronasal mask, nasal mask, full-face mask, and helmet. In addition, some favorable outcomes related to NIV were reported in the studies, such as a reduction in the rate of orotracheal intubation and shorter length of stay in the ICU. Conclusions: The most cited interfaces in the treatment of ARF were the oronasal mask and the helmet.展开更多
Objective:To investigate the effects of prone ventilation in patients with severe traumatic brain injury combined with pulmonary infection.Methods:A total of 100 patients with severe traumatic brain injury combined wi...Objective:To investigate the effects of prone ventilation in patients with severe traumatic brain injury combined with pulmonary infection.Methods:A total of 100 patients with severe traumatic brain injury combined with pulmonary infection in the hospital were randomly divided into a prone ventilation group and a conventional ventilation group,with 50 patients in each group.The Glasgow Coma Scale(GCS)score,APACHE II score,sputum culture results,oxygenation indicators,and prognosis were compared between the two groups.Data were processed using SPSS 25.0 statistical software,and t-tests and chi-square tests were used to compare continuous and categorical variables,respectively.Results:The experimental group showed better oxygenation indicators,a lower positive rate of sputum cultures,and reduced intracranial pressure compared to the control group(all P<0.05).Multivariate Cox regression analysis indicated that GCS score,APACHE II score,and prone ventilation were independent risk factors affecting patient prognosis(all P<0.05).Conclusion:Prone ventilation can improve oxygenation,reduce the risk of pulmonary infection,and decrease intracranial pressure in patients with severe traumatic brain injury combined with pulmonary infection,thereby improving patient prognosis.GCS score and APACHE II score can serve as important indicators for prognostic evaluation.展开更多
Controlled,guided munitions can reduce dispersion in the shot,while providing the capability of engaging both stationary and maneuvering targets.The Netherlands Organisation for Applied Scientific Research has develop...Controlled,guided munitions can reduce dispersion in the shot,while providing the capability of engaging both stationary and maneuvering targets.The Netherlands Organisation for Applied Scientific Research has developed a fin-less control technology called Stagnation Pressure Reaction Control(SPRC)that takes stagnation pressure air and directs it sideways to control non-spinning projectiles.In a previous study,this technology was demonstrated at Mach 2 wind-tunnel conditions to achieve up to 1.5°controllable angle of incidence for a non-spinning,aerodynamically unstable projectile-like test object.In an operational scenario,the decelerating projectile will experience a decline in control force while the simultaneous forward shift of the center of pressure increases the need for control force.Furthermore,angles of incidence exceeding 1.5°will be experienced under realistic flight conditions,especially against maneuvering targets.This work addresses these challenges and presents an operational feasibility study for a practical application of SPRC in a non-spinning mid-caliber gun-launched projectile,using experiment data on control latency and force of the earlier study.It illustrates the combined effect of the control-and stability dynamics and underlines the potential of an SPRC projectile as a precisionoperation ammunition.This research revealed that SPRC technology can stabilize and control the hypothesized projectile in a direct fire scenario against stationary and maneuvering targets.展开更多
文摘Driving pressure(ΔP)is a core therapeutic component of mechanical ventilation(MV).Varying levels ofΔP have been employed during MV depending on the type of underlying pathology and severity of injury.However,ΔP levels have also been shown to closely impact hard endpoints such as mortality.Considering this,conducting an in-depth review ofΔP as a unique,outcome-impacting therapeutic modality is extremely important.There is a need to understand the subtleties involved in making sureΔP levels are optimized to enhance outcomes and minimize harm.We performed this narrative review to further explore the various uses ofΔP,the different parameters that can affect its use,and how outcomes vary in different patient populations at different pressure levels.To better utilizeΔP in MV-requiring patients,additional large-scale clinical studies are needed.
文摘BACKGROUND Neonatal respiratory distress syndrome(NRDS)is one of the most common diseases in neonatal intensive care units,with an incidence rate of about 7%among infants.Additionally,it is a leading cause of neonatal death in hospitals in China.The main mechanism of the disease is hypoxemia and hypercapnia caused by lack of surfactant AIM To explore the effect of pulmonary surfactant(PS)combined with noninvasive positive pressure ventilation on keratin-14(KRT-14)and endothelin-1(ET-1)levels in peripheral blood and the effectiveness in treating NRDS.METHODS Altogether 137 neonates with respiratory distress syndrome treated in our hospital from April 2019 to July 2021 were included.Of these,64 control cases were treated with noninvasive positive pressure ventilation and 73 observation cases were treated with PS combined with noninvasive positive pressure ventilation.The expression of KRT-14 and ET-1 in the two groups was compared.The deaths,complications,and PaO_(2),PaCO_(2),and PaO_(2)/FiO_(2)blood gas indexes in the two groups were compared.Receiver operating characteristic curve(ROC)analysis was used to determine the diagnostic value of KRT-14 and ET-1 in the treatment of NRDS.RESULTS The observation group had a significantly higher effectiveness rate than the control group.There was no significant difference between the two groups in terms of neonatal mortality and adverse reactions,such as bronchial dysplasia,cyanosis,and shortness of breath.After treatment,the levels of PaO_(2)and PaO_(2)/FiO_(2)in both groups were significantly higher than before treatment,while the level of PaCO_(2)was significantly lower.After treatment,the observation group had significantly higher levels of PaO_(2)and PaO_(2)/FiO_(2)than the control group,while PaCO_(2)was notably lower in the observation group.After treatment,the KRT-14 and ET-1 levels in both groups were significantly decreased compared with the pre-treatment levels.The observation group had a reduction of KRT-14 and ET-1 levels than the control group.ROC curve analysis showed that the area under the curve(AUC)of KRT-14 was 0.791,and the AUC of ET-1 was 0.816.CONCLUSION Combining PS with noninvasive positive pressure ventilation significantly improved the effectiveness of NRDS therapy.KRT-14 and ET-1 levels may have potential as therapeutic and diagnostic indicators.
文摘Objective:This study aims to evaluate the clinical efficacy of non-invasive positive pressure ventilation(NIPPV)in patients with severe bronchial asthma combined with respiratory failure.Methods:90 patients with severe bronchial asthma combined with respiratory failure between September 2022 and December 2023 were selected for the study and randomly divided into the experimental group(NIPPV-assisted treatment)and the control group.The differences between the two groups were compared in terms of total effective rate of treatment,days of clinical symptom disappearance,days of hospitalization,lung function indexes,incidence of adverse reactions,and quality of life.Results:Patients in the experimental group had a significantly higher total effective rate of treatment(97.78%)than the control group(75.56%).In terms of pulmonary function indexes,patients in the experimental group showed significant improvement after treatment,especially the increase in forced expiratory volume and forced vital capacity,while these improvements were not as obvious in the control group.In addition,the incidence of adverse reactions was significantly lower in the experimental group than in the control group,suggesting that the application of NIPPV is relatively safe.Quality of life assessment also showed that patients in the experimental group had significantly better quality of life than the control group after treatment.Conclusion:This study demonstrated the effectiveness of NIPPV as an adjunctive treatment for severe bronchial asthma combined with respiratory failure.NIPPV can improve lung function,reduce the incidence of adverse effects,increase the overall effectiveness of the treatment,and contribute to the improvement of patients'quality of life.Therefore,NIPPV should be regarded as an effective and safe treatment in clinical management,especially in patients with severe bronchial asthma combined with respiratory failure,where its application has potential clinical significance.
基金supported by the Structures and Materials(S&M)Research Lab of Prince Sultan Universitysupport of Prince Sultan University in paying the article processing charges(APC)for this publication.
文摘When better fuel-air mixing in the combustion chamber or a reduction in base drag are required in vehicles,rockets,and aeroplanes,the base pressure control is activated.Controlling the base pressure and drag is necessary in both scenarios.In this work,semi-circular ribs with varying diameters(2,4,and 6 mm)positioned at six distinct positions(0.5D,1D,1.5D,2D,3D,and 4D)inside a square duct with a side of 15 mm are proposed as an efficient way to apply the passive control technique.In-depth research is done on optimising rib size for various rib sites.According to this study,the base pressure rises as rib height increases.Furthermore,the optimal location for the semi-circular ribs with a diameter of 2 mm is at 0.5D.The 1D location appears to be optimal for the 4 mm size as well.For the 6 mm size,however,the 4D position fills this function.
文摘Introduction: High blood pressure is defined as blood pressure greater than or equal to 140 mm Hg for systolic and or 90 mm Hg for diastolic. It constitutes a major public health problem, the leading chronic disease in the world. The objective was to determine the prevalence, treatment rate and control of hypertension. Methods: This was a cross-sectional and descriptive study which took place over a period of 6 months in a hospital environment and in the general population. Results: Of the 1000 participants, 637 had hypertension, giving a prevalence of 63.70% with a female predominance. Thirty-three percent (33%) were unaware of their high blood pressure. The age group 60 and more was the most represented (44%). A proportion of 33 and 23.20 were overweight and obese participants, respectively. Male subjects were more overweight than female, unlike obesity which was more common among female subjects. Sixty-two percent (62%) of hypertensives were treated, of whom 44% were non-compliant. The excessively high cost and consumption of medications as needed were the main factors in therapeutic non-compliance. Twenty-two percent (22%) of all hypertensive patients and 35% of treated hypertensive patients were controlled. Women were more treated but less observant and less controlled than men. Therapeutic coverage and combination therapy rates were lower in rural areas. Hypertensives who had a high level of education were better treated and controlled than those who had no level. Conclusion: High blood pressure remains a real public health problem in Mali. It is more common in people aged 60 and over and in females. One in three hypertensives were unaware of their hypertension. The majority received antihypertensive treatments, but only a minority of them had their hypertension controlled.
文摘Objective: The association hypertension and diabetes is important. The two pathologies may influence each other. The aim was to study the correlation between glycemic control and blood pressure control and to determine the factors associated with blood pressure control. Methodology: This was a descriptive cross-sectional study with an analytical focus over 7 months. Patients were recruited as outpatients and all underwent ambulatory blood pressure measure, glycated hemoglobin and creatinine measurements, and assessment of compliance with treatment. Results: During this period 116 patients were collected. The predominance was female 69%. The mean age of the patients was 62 ± 7 years with a peak between 60 and 70 years. The average age of hypertension was 12 years and that of diabetes 6 1/2 years. The most frequently associated cardiovascular risk factor was a sedentary lifestyle (71.5%) after age. 57.8% of patients were not controlled at the office, with a predominance of systolic hypertension (58.2%). 61.6% of patients were controlled by ambulatory blood pressure measure, a rate of 47.8% of white coat hypertension. Glycemic control was observed in 42.2% of cases and 87% of patients had good renal function (glomerular filter rate ≥ 60 ml/mn). Therapeutic compliance was good in 53.4% of cases and dual therapy was the most used therapeutic modality 44.8% (52 patients) followed by triple therapy. The factors associated with poor blood pressure control were glycemic imbalance, non-compliance and monotherapy. Dual therapy had a protective effect. Conclusion: The association of hypertension and type 2 diabetes is frequent. The risk of occurrence increases with age. Ambulatory blood pressure measure is the best method to assess blood pressure control. Optimization of blood pressure control should also include optimization of glycemic control.
文摘Nuclear power plants exhibit non-linear and time-variable dynamics.Therefore,designing a control system that sets the reactor power and forces it to follow the desired load is complicated.A supercritical water reactor(SCWR)is a fourth-generation conceptual reactor.In an SCWR,the non-linear dynamics of the reactor require a controller capable of control-ling the nonlinearities.In this study,a pressure-tube-type SCWR was controlled during reactor power maneuvering with a higher order sliding mode,and the reactor outgoing steam temperature and pressure were controlled simultaneously.In an SCWR,the temperature,pressure,and power must be maintained at a setpoint(desired value)during power maneuvering.Reactor point kinetics equations with three groups of delayed neutrons were used in the simulation.Higher-order and classic sliding mode controllers were separately manufactured to control the plant and were compared with the PI controllers speci-fied in previous studies.The controlled parameters were reactor power,steam temperature,and pressure.Notably,for these parameters,the PI controller had certain instabilities in the presence of disturbances.The classic sliding mode controller had a higher accuracy and stability;however its main drawback was the chattering phenomenon.HOSMC was highly accurate and stable and had a small computational cost.In reality,it followed the desired values without oscillations and chattering.
文摘Objectives: To assess respiratory elastance and resistive properties in patients with autoimmune liver disorders using the passive relaxation expiration technique and compare findings to a group of patients with non-autoimmune liver disease and control subjects. These findings were then related to control of ventilation and gas exchange. A secondary objective was to assess respiratory muscle strength and gas exchange and their relation to respiratory mechanics. Methods: Measurements included respiratory elastance and resistance using the passive relaxation method. Pulmonary function, gas exchange and control of ventilation were assessed using standard methods. Results: a) Compared to control subjects, Ers in patients with liver disease was on average 50% greater than in controls;b) mean respiratory resistance, expressed as the respiratory constants, K<sub>1</sub> and K<sub>2</sub> in the Rohrer relationship, Pao/V’ = K<sub>1</sub> + K<sub>2</sub>V’, was not different from control resistance;c) mean maximal inspiratory and maximal expiratory pressures averaged 36% and 55% of their respective control values;d) inspiratory occlusion pressure in 0.1 sec (P<sub>0.1</sub>) was increased and negatively associated with FVC;and e) increases in P<sub>0.1</sub>, mean inspiratory flow (Vt/Ti) and presence of respiratory alkalosis confirmed the increase in ventilatory drive. Despite inspiratory muscle weakness in patients, P<sub>0.1</sub>/Pimax averaged 5-fold higher than in control subjects. Conclusions: Despite inspiratory muscle weakness and a V’<sub>E</sub> similar to that in normal subjects, central drive is increased in patients with chronic liver disease. The increase in ventilatory drive is related to smaller lung volumes and weakly associated with increase in respiratory elastance. Findings confirm that P<sub>0.1</sub> is a reliable measure of central drive and is an approach that can be used in the evaluation of control of ventilation in patients with chronic liver disease.
基金supported by National Natural Science Foundation of China(No.41576108 and No.41605006)Natural Science Foundation project of Shandong Province(No.ZR2016DB26).
文摘Based on the principle of transient perturbation analysis,in this paper,a method to objectively determine the weather pattern formed by sea fog is provided.On the basis of the classification results,the circulation situation,divergence and vertical velocity field,and the vertical profile of temperature and humidity are synthesized and analyzed.The basic characteristics of the circulation and physical field of sea fog under low pressure control(L type sea fog)are obtained,and the results are compared with the sea fog under the control of high pressure(H type sea fog):a)L type sea fogs potential height anomaly disturbance is mainly manifested in the low layer,and its average value is-65.66 gpm,gradually weakening upward;b)L type sea fogs inversion structure is weaker than H type sea fogs when it occurs,the fog layer is thicker and the high relative humidity level is high over the fog layer,while the H type sea fogs fog layer has a relatively obvious dry layer;c)L sea fog has three layers of structure at the vertical direction.The first layer 1000-950 hPa is convergence accompanied by weak rise and subsidence,the second layer 950-850 hPa is divergence accompanied by weak subsidence,and the third layer 850 to 500hPa is gradually strengthened.While there are two layer structures of the H type sea fog.1000 hPa is divergence accompanied by weak rising and sinking movement,950-500 hPa is a uniform subsidence movement.d)Probability density statistical analysis further quantified the vertical movement of L and H type sea fog and the distribution of relative humidity in each layer.These conclusions provide an important reference for forecasting the sea fog in the northwest of the Yellow Sea under the condition of low pressure circulation in summer.
文摘A pressure controlled mechanical ventilator with an automatic secretion clearance function can improve secretion clearance safely and efficiently.Studies on secretion clearance by pressure controlled systems show that these are suited for clinical applications.However,these studies are based on a single lung electric model and neglect the coupling between the two lungs.The research methods applied are too complex for the analysis of a multi-parameter system.In order to understand the functioning of the human respiratory system,this paper develops a dimensionless mathematical model of doublelung mechanical ventilation system with a secretion clearance function.An experiment is designed to verify the mathematical model through comparison of dimensionless experimental data and dimensionless simulation data.Finally,the coupling between the two lungs is studied,and an orthogonal experiment designed to identify the impact of each parameter on the system.
文摘A mathematical model of mechanical ventilator describes its behavior during artificial ventilation. This paper purposes to create and simulate Mathematical Model (MM) of Pressure Controlled Ventilator (PCV) signal. This MM represents the respiratory activities and an important controlled parameter during mechanical ventilation—Positive End Expiration Pressure (PEEP). The MM is expressed and modelled using periodic functions with inequalities to control the beginning of inspiration and expiration durations. The created MM of PCV signal is combined with an existing multi compartmental model of respiratory system that is modified and developed in the internal parameters—compliances (C) to test created MM. The created MM and model of respiratory system are constructed and simulated using Simulink package in MATLAB platform. The obtained simulator of mechnical ventilation system could potentially represent the pressure signal of PVC as a complete respiratory cycle and continuance waveform. This simulator is also able to reflect a respiratory mechanic by changing some input variables such as inspiration pressure (IP), PEEP and C, which are monitored in volume, flow, pressure and PV loop waveforms. The obtained simulator has provided a simple environment for testing and monitoring PCV signal and other parameters (volume, flow and dynamic compliance) during artificial ventilation. Furthermore, the simulator may be used for studying in the laboratory and training ventilator’s operators.
文摘The present paper describes the theoretical treatment performed for the geometrical optimization of advanced and improved-shape waveforms as airways pressure excitation for controlled breathings in dual-controlled ventilation applied to anaesthetized or severe brain injured patients, the respiratory mechanics of which can be assumed linear. Advanced means insensitive to patient breathing activity as well as to ventilator settings while improved-shape intends in comparison to conventional square waveform for a progressive approaching towards physiological transpulmonary pressure and respiratory airflow waveforms. Such functional features along with the best ventilation control for the specific therapeutic requirements of each patient can be achieved through the implementation of both diagnostic and compensation procedures effectively carried out by the Advance Lung Ventilation System (ALVS) already successfully tested for square waveform as airways pressure excitation. Triangular and trapezoidal waveforms have been considered as airways pressure excitation. The results shows that the latter fits completely the requirements for a physiological pattern of endoalveolar pressure and respiratory airflow waveforms, while the former exhibits a lower physiological behaviour but it is anyhow periodically recommended for performing adequately the powerful diagnostic procedure.
基金This study was funded by Major Science and Technology Projects of Jiangxi Provincial Science and Technology Department(20152ACG70009).
文摘Objective:The purpose of the study was to assess the clinical efficacy and safety of a combined perfusion suction platform with pressure feedback control function and an ureteroscopic suction sheath that can measure the ureteropelvic pressure in implementing lithotripsies.Methods:Fifty-two patients who underwent lithotripsy under intelligent monitoring of ureteral intraluminal pressure from June 2016 to January 2018 were retrospectively recruited.The inclusion standard was stone diameter>1.5 cm but<2.5 cm.After the 12/14 Fr suction sheath was placed,manometer interface and suction interface of the sheath were connected to the platform via the pressure sensor and suction tube,respectively.The ureteroscope was connected to the platform perfusion pump,and the crushed stones were aspirated out under negative pressure.Results:According to the location of the stone,21(40.4%)cases were classified as upper ureteral stones,19(36.5%)were midureteral stones,and 12(23.1%)were lower ureteral stones.Forty-seven patients underwent successful primary sheath placement and lithotripsy with a mean operative time of 34.5(standard deviation 18.3)min.Retrograde stone migration did not occur.There were eight patients with hematuria postoperatively.Serious complication was 1.9% with one case of ureteral perforation.Stone clearance was 95.7% at Day 1e2 postoperatively,and 100% at Day 30 postoperatively.Conclusion:Ureteroscopic lithotripsy with intelligent pressure control using our device improved the efficiency of the lithotripsy and rate of stone clearance.The safety of the operation can be ensured.It is worth popularization and application in clinical practice.
基金The authors are grateful for the financial support from the National Natural Science Foundation of China(No.51827901&No.52274133)the Program for Guangdong Introducing Innovative and Enterpreneurial Teams(No.2019ZT08G315)the Shenzhen National Science Fund for Distinguished Young Scholars(RCJC20210706091948015).
文摘In-situ pressure-preserved coring(IPP-Coring)is considered to be the most reliable and efficient method for the identification of the scale of oil and gas resources.During IPP-Coring,because the rotation behavior of the pressure controller valve cover in different medium environments is unclear,interference between the valve cover and inner pipe may occur and negatively affect the IPP-Coring success rate.To address this issue,we conducted a series of indoor experiments employing a high-speed camera to gain greater insights into the valve cover rotation behavior in different medium environments,e.g.,air,water,and simulated drilling fluids.The results indicated that the variation in the valve cover rotation angle in the air and fluid environments can be described by a one-phase exponential decay function with a constant time parameter and by biphasic dose response function,respectively.The rotation behavior in the fluid environments exhibited distinct elastic and gravitational acceleration zones.In the fluid environments,the density clearly impacted the valve cover closing time and rotation behavior,whereas the effect of viscosity was very slight.This can be attributed to the negligible influence of the fluid viscosity on the drag coefficient found in this study;meanwhile,the density can increase the buoyancy and the time period during which the valve cover experienced a high drag coefficient.Considering these results,control schemes for the valve cover rotation behavior during IPP-Coring were proposed for different layers and geological conditions in which the different drilling fluids should be used,e.g.,the use of a high-density valve cover in high-pore pressure layers.
文摘The operating room is a unique environment where surgery exposes patients to non-physiological changes that can compromise lung mechanics.Therefore,raising clinicians’awareness of the potential risk of ventilator-induced lung injury(VILI)is mandatory.Driving pressure is a useful tool for reducing lung complications in patients with acute respiratory distress syndrome and those undergoing elective surgery.Driving pressure has been most extensively studied in the context of single-lung ventilation during thoracic surgery.However,the awareness of association of VILI risk and patient positioning(prone,beach-chair,parkbench)and type of surgery must be raised.
基金The Project of the National Ministry of Industry and Information Technology[2020-0103-3-1-1]The Project of Beijing Science and technology“capital characteristics”[Z181100001718007]。
文摘Objective Current clinical evidence on the effects of home blood pressure telemonitoring(HBPT)on improving blood pressure control comes entirely from developed countries.Thus,we performed this randomized controlled trial to evaluate whether HBPT plus support(patient education and clinician remote hypertension management)improves blood pressure control more than usual care(UC)in the Chinese population.Methods This single-center,randomized controlled study was conducted in Beijing,China.Patients aged 30-75 years were eligible for enrolment if they had blood pressure[systolic(SBP)≥140 mmHg and/or diastolic(DBP)≥90 mmHg;or SBP≥130 mmHg and/or DBP≥80 mmHg with diabetes].We recruited 190 patients randomized to either the HBPT or the UC groups for 12 weeks.The primary endpoints were blood pressure reduction and the proportion of patients achieving the target blood pressure.Results Totally,172 patients completed the study,the HBPT plus support group(n=84),and the UC group(n=88).Patients in the plus support group showed a greater reduction in mean ambulatory blood pressure than those in the UC group.The plus support group had a significantly higher proportion of patients who achieved the target blood pressure and maintained a dipper blood pressure pattern at the12th week of follow-up.Additionally,the patients in the plus support group showed lower blood pressure variability and higher drug adherence than those in the UC group.Conclusion HBPT plus additional support results in greater blood pressure reduction,better blood pressure control,a higher proportion of dipper blood pressure patterns,lower blood pressure variability,and higher drug adherence than UC.The development of telemedicine may be the cornerstone of hypertension management in primary care.
文摘Mechanical ventilation(MV)is an important strategy for improving the survival of patients with respiratory failure.However,MV is associated with aggravation of lung injury,with ventilator-induced lung injury(VILI)becoming a major concern.Thus,ventilation protection strategies have been developed to minimize complications from MV,with the goal of relieving excessive breathing workload,improving gas exchange,and minimizing VILI.By opting for lower tidal volumes,clinicians seek to strike a balance between providing adequate ventilation to support gas exchange and preventing overdistension of the alveoli,which can contribute to lung injury.Additionally,other factors play a role in optimizing lung protection during MV,including adequate positive end-expiratory pressure levels,to maintain alveolar recruitment and prevent atelectasis as well as careful consideration of plateau pressures to avoid excessive stress on the lung parenchyma.
文摘Background: Noninvasive ventilation (NIV) is an important therapeutic modality for the treatment of acute respiratory failure (ARF). In this review, we critically analyze randomized controlled trials on the most used NIV interfaces in the treatments of ARF. Methods: The searches were conducted in the Medline, Lilacs, PubMed, Cochrane, and Pedro databases from June to November 2021. The inclusion criteria were Randomized clinical trials (RCTs) published from 2016 to 2021 in Portuguese, Spanish, or English and involving adults (aged ≥ 18 years). The eligibility criteria for article selection were based on the PICO strategy: Population—Adults with ARF;Intervention—NIV Therapy;Comparison—Conventional oxygen therapy, high-flow nasal cannula (HFNC) oxygen therapy, or NIV;Outcome—improvement in ARF. The search for articles and the implementation of the inclusion criteria were independently conducted by two researchers. Results: Seven scientific articles involving 574 adults with ARF due to various causes, such as chest trauma, decompensated heart failure, coronavirus disease 2019 (COVID-19), and postoperative period, among others, were included. The interfaces cited in the studies included an oronasal mask, nasal mask, full-face mask, and helmet. In addition, some favorable outcomes related to NIV were reported in the studies, such as a reduction in the rate of orotracheal intubation and shorter length of stay in the ICU. Conclusions: The most cited interfaces in the treatment of ARF were the oronasal mask and the helmet.
基金Research Project of the 900th Hospital of Joint Logistics Support Force(Project No.2020L30)。
文摘Objective:To investigate the effects of prone ventilation in patients with severe traumatic brain injury combined with pulmonary infection.Methods:A total of 100 patients with severe traumatic brain injury combined with pulmonary infection in the hospital were randomly divided into a prone ventilation group and a conventional ventilation group,with 50 patients in each group.The Glasgow Coma Scale(GCS)score,APACHE II score,sputum culture results,oxygenation indicators,and prognosis were compared between the two groups.Data were processed using SPSS 25.0 statistical software,and t-tests and chi-square tests were used to compare continuous and categorical variables,respectively.Results:The experimental group showed better oxygenation indicators,a lower positive rate of sputum cultures,and reduced intracranial pressure compared to the control group(all P<0.05).Multivariate Cox regression analysis indicated that GCS score,APACHE II score,and prone ventilation were independent risk factors affecting patient prognosis(all P<0.05).Conclusion:Prone ventilation can improve oxygenation,reduce the risk of pulmonary infection,and decrease intracranial pressure in patients with severe traumatic brain injury combined with pulmonary infection,thereby improving patient prognosis.GCS score and APACHE II score can serve as important indicators for prognostic evaluation.
文摘Controlled,guided munitions can reduce dispersion in the shot,while providing the capability of engaging both stationary and maneuvering targets.The Netherlands Organisation for Applied Scientific Research has developed a fin-less control technology called Stagnation Pressure Reaction Control(SPRC)that takes stagnation pressure air and directs it sideways to control non-spinning projectiles.In a previous study,this technology was demonstrated at Mach 2 wind-tunnel conditions to achieve up to 1.5°controllable angle of incidence for a non-spinning,aerodynamically unstable projectile-like test object.In an operational scenario,the decelerating projectile will experience a decline in control force while the simultaneous forward shift of the center of pressure increases the need for control force.Furthermore,angles of incidence exceeding 1.5°will be experienced under realistic flight conditions,especially against maneuvering targets.This work addresses these challenges and presents an operational feasibility study for a practical application of SPRC in a non-spinning mid-caliber gun-launched projectile,using experiment data on control latency and force of the earlier study.It illustrates the combined effect of the control-and stability dynamics and underlines the potential of an SPRC projectile as a precisionoperation ammunition.This research revealed that SPRC technology can stabilize and control the hypothesized projectile in a direct fire scenario against stationary and maneuvering targets.