期刊文献+
共找到1,707篇文章
< 1 2 86 >
每页显示 20 50 100
Anti-plane pull-out of a rigid line inclusion from an elastic medium
1
作者 Yansong WANG Baolin WANG +1 位作者 Youjiang CUI Kaifa WANG 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2023年第5期809-822,共14页
The transient and static anti-plane problem of a rigid line inclusion pulled out from an elastic medium is studied.The singular integral equation method is used to solve the stress field.Under the static load,the stre... The transient and static anti-plane problem of a rigid line inclusion pulled out from an elastic medium is studied.The singular integral equation method is used to solve the stress field.Under the static load,the stress intensity factor(SIF)at the inclusion tips increases with the medium length.The problem becomes equivalent to an inclusion in a medium with an infinite length when the length of the medium is 3.5times longer than that of the inclusion.However,under the transient load,the maximum value of the SIF occurs when the medium length is about two times the inclusion length.Besides,the relation between the pull-out force and the anti-plane displacement is given.The conclusions are useful in guiding the design of fiber reinforced composite materials. 展开更多
关键词 pull-out rigid line inclusion ANTI-PLANE stress intensity factor(SIF) stress singularity
下载PDF
Laboratory pull-out tests on fully grouted rock bolts and cable bolts:Results and lessons learned 被引量:19
2
作者 Isabelle Thenevin Laura Blanco-Martín +3 位作者 Faouzi Hadj-Hassen Jacques Schleifer Zbigniew Lubosik Aleksander Wrana 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2017年第5期843-855,共13页
Laboratory pull-out tests were conducted on the following rock bolts and cable bolts:steel rebars,smooth steel bars,fiberglass reinforced polymer threaded bolts,flexible cable bolts,IR5/IN special cable bolts and Mini... Laboratory pull-out tests were conducted on the following rock bolts and cable bolts:steel rebars,smooth steel bars,fiberglass reinforced polymer threaded bolts,flexible cable bolts,IR5/IN special cable bolts and Mini-cage cable bolts.The diameter of the tested bolts was between 16 mm and 26 mm.The bolts were grouted in a sandstone sample using resin or cement grouts.The tests were conducted under either constant radial stiffness or constant confining pressure boundary conditions applied on the outer surface of the rock sample.In most tests,the rate of displacement was about 0.02 mm/s.The tests were performed using a pull-out bench that allows testing a wide range of parameters.This paper provides an extensive database of laboratory pull-out test results and confirms the influence of the confining pressure and the embedment length on the pull-out response(rock bolts and cable bolts).It also highlights the sensitivity of the results to the operating conditions and to the behavior of the sample as a whole,which cannot be neglected when the test results are used to assess the bolt-grout or the grouterock interface. 展开更多
关键词 pull-out test Fully grouted bolts Laboratory-scale Confining pressure Embedment length Bolt-grout interface
下载PDF
Tapered Suction Caissons:A Numerical Investigation into Their Pull-out Performance 被引量:5
3
作者 M.Zeinoddini J.Keyvani M.Nabipour 《China Ocean Engineering》 SCIE EI 2009年第4期695-707,共13页
Suction caissons have been widely used as anchors and foundations for floating and fixed offshore platforms. The pull-out performance of conventional suction caissons (with upright walls) has been investigated by a ... Suction caissons have been widely used as anchors and foundations for floating and fixed offshore platforms. The pull-out performance of conventional suction caissons (with upright walls) has been investigated by a number of researchers. However, no attention has been paid to tapered suction caissons. This paper deals with the performance of tapered suction caissons under vertical pull-out loads. A numerical approach is used for this purpose. The numerical model is first verified against test data available for common upright caissons. The verified model is then used to study the pullout performance of tapered suction caissons. It is noticed that the pull-out capacities exhibited by tapered suction caissons are in general considerably higher than those from their corresponding traditional upright caissons. To obtain an insight into this superior behaviour, effects from certain soil/caisson/drainage parameters on the pull-out capacity of tapered suction caissons are studied. Soil cohesion is noticed to have a linear improving effect on the capacity of both upright and ta- pered suction caissons. The soil internal friction angle is noticed to have an exponential increasing effect on the pull-out capacity. With a constant caisson diameter, an increase in the aspect ratio is seen to particularly influence the pull-out capacity. With a constant caisson length, an increase in the aspect ratio is discovered to result in non-linear decrease in the pull-out capacity. Under undrained conditions, tapered models generally show less sensitivity to above mentioned soil/caisson parameters as compared with those under drained conditions. 展开更多
关键词 suction caisson pull-out capacity numerical study upright caisson tapered caisson offshore structure sand clay drained UNDRAINED
下载PDF
Pull-out tests and slope stability analyses of nailing systems comprising single and multi rebars with grouted cement 被引量:6
4
作者 Sang-Soo Jeon 《Journal of Central South University》 SCIE EI CAS 2012年第1期262-272,共11页
The pull-out capacities for soil nailing systems comprising of one single 29 mm diameter(type A) and four 16 mm diameter(type B) rebars with grouted cement were examined.A field test and numerical analysis for the typ... The pull-out capacities for soil nailing systems comprising of one single 29 mm diameter(type A) and four 16 mm diameter(type B) rebars with grouted cement were examined.A field test and numerical analysis for the type A and type B systems were carried out to investigate the pull-out capacities and the slope stability reinforcement efficiency in soil and rock slopes.The results of the pull-out tests show the mobilized shear force and load transfer characteristics with respect to soil depth.The load-displacement relationship was examined for both type A and type B systems.Slope stability analyses were carried out to study the relationships between soil and nail reinforcement and bending stiffness as well as combined axial tension and shear forces.Factors of safety were calculated in relation to the number of nails and their outside diameters.Both soil and rock slopes were included in this evaluation. 展开更多
关键词 soil nailing bending resistance pull-out test finite difference method
下载PDF
Effects of different pull-out loading rates on mechanical behaviors and acoustic emission responses of fully grouted bolts 被引量:4
5
作者 DU Yun-lou FENG Guo-rui +2 位作者 KANG Hong-pu ZHANG Yu-jiang ZHANG Xi-hong 《Journal of Central South University》 SCIE EI CAS CSCD 2021年第7期2052-2066,共15页
Due to the influence of mining disturbance stress,it is of great significance to better understand the bearing characteristics of fully grouted bolts under different pull-out loading rates.For this purpose,a series of... Due to the influence of mining disturbance stress,it is of great significance to better understand the bearing characteristics of fully grouted bolts under different pull-out loading rates.For this purpose,a series of laboratory pull-out tests were conducted to comprehensively investigate the effects of different pull-out loading rates on the mechanical performance and failure characteristics of fully grouted bolts.The results show that the mechanical performance of the anchored specimen presents obvious loading rate dependence and shear enhancement characteristics.With the increase of the pull-out loading rates,the maximum pull-out load increases,the displacement and time corresponding to the maximum pull-out load decrease.The accumulated acoustic emission(AE)counts,AE energy and AE events all decrease with the increase of the pull-out loading rates.The AE peak frequency has obvious divisional distribution characteristics and the amplitude is mainly distributed between 50-80 dB.With the increase of the pull-out loading rates,the local strain of the anchoring interface increases and the failure of the anchoring interface transfers to the interior of the resin grout.The accumulated AE counts are used to evaluate the damage parameter of the anchoring interface during the whole pull-out process.The analytical results are in good agreement with the experimental results.The research results may provide guidance for the support design and performance monitoring of fully grouted bolts. 展开更多
关键词 fully grouted bolts pull-out test loading rate mechanical behavior AE response failure characteristic
下载PDF
DYNAMIC CRACK MODELS ON PROBLEM OF BRIDGING FIBER PULL-OUT OF COMPOSITE MATERIALS 被引量:1
6
作者 吕念春 程云虹 +2 位作者 胥红敏 程靳 唐立强 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2004年第10期1194-1202,共9页
An elastic analysis of an internal central crack with bridging fibers parallel to the free surface in an infinite orthotropic anisotropic elastic plane was performed. A dynamic model of bridging fiber pull-out of comp... An elastic analysis of an internal central crack with bridging fibers parallel to the free surface in an infinite orthotropic anisotropic elastic plane was performed. A dynamic model of bridging fiber pull-out of composite materials was presented. Resultingly the fiber failure is governed by maximum tensile stress, the fiber breaks and hence the crack extension should occur in self-similar fashion. By the methods of complex functions, the problem studied can be transformed into the dynamic model to the Reimann-Hilbert mixed boundary value problem, and a straightforward and easy analytical solution is presented. Analytical study on the crack propagation subjected to a ladder load and an instantaneous pulse loading is obtained respectively for orthotropic anisotropic body. By utilizing the solution, the concrete solutions of this model are attained by ways of superposition. 展开更多
关键词 bridging fiber pull-out CRACK dynamic model analytical solution
下载PDF
Experimental Study on Pull-out Behavior of Different Geotextiles 被引量:1
7
作者 周蓉 丁辛 《Journal of Donghua University(English Edition)》 EI CAS 2007年第4期497-499,共3页
The pullout testing of geosynthetics is essential for studying interface interaction in the soil-reinforcement system. In this paper, a new method for testing interface properties of geotextiles is proposed. The inter... The pullout testing of geosynthetics is essential for studying interface interaction in the soil-reinforcement system. In this paper, a new method for testing interface properties of geotextiles is proposed. The interface frictional characters of two kinds of geotextiles (woven and needle-punched nonwoven) are investigated through pullout test. Nonwoven specimen has more wide variety of displacement along length than that of woven under the same pressure because of their different extensibility. The greater the elongation and deformation of specimens, the more evident the variations of displacement along reinforcement from front to pullout end. The greater the normal pressure, the smaller the displacement of every position along length with the same pullout load. The study focuses on the effects of the tensile modulus and the difference of pullout response between woven and nonwoven geotextiles. 展开更多
关键词 GEOTEXTILE pull-out COMPARE normal pressure tensile modulus
下载PDF
Mechanical Characterisation of Interface for Steel/Polymer Composite Using Pull-out Test: Shear-Lag and Frictional Analysis
8
作者 Mohamed KHARRAT Maher DAMMAK Amine CHARFI 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2006年第4期552-558,共7页
Fibre-matrix interface is known to have contribution to the mechanical performance of fibre-reinforced composite by its potential for load transfer between the fibre and the matrix. Such load transfer is of great impo... Fibre-matrix interface is known to have contribution to the mechanical performance of fibre-reinforced composite by its potential for load transfer between the fibre and the matrix. Such load transfer is of great importance in dentistry when a post is used for fixing a ceramic crown on the tooth. In this study, a pull-out test was carried out to analyse the interfacial properties of a steel fibre embedded in a polyester and epoxy matrices. It was found that the fibre-matrix interface is debonded on the whole embedded length when the fibre stress reached the debonding stress. Then, the fibre stress fell down to the initial extraction stress required to pulling out the debonded fibre from the matrix. Both debonding stress and initial extraction stress initiated a linear increase with the implantation length after the debonding stress reached horizontal asymptotes. To analyse the fibre-matrix load transfer before debonding, an analytical shear-lag model was adopted to in this test conditions. Fitting the experimental results with the analytical model provided the interfacial shear strength. By considering the Coulomb friction at the fibre-matrix interface during the fibre extraction process, an analytical model which considers Poisson's effects on both fibre and matrix, was developed. In this model, knowledge of the initial extraction stress of the fibre provides the residual normal stress at the fibre-matrix interface. 展开更多
关键词 FIBRE Matrix INTERFACE pull-out Shear-lag DEBONDING FRICTION
下载PDF
Properties of frictional bridging in fiber pull-out for fiber-reinforced composites
9
作者 刘鹏飞 陶伟明 郭乙木 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第B08期8-16,共9页
Stress equilibrium equations, boundary- and continuity-conditions were used to establish a theoretical model of progressive debonding with friction at the debonded interface. On a basis of the minimum complementary en... Stress equilibrium equations, boundary- and continuity-conditions were used to establish a theoretical model of progressive debonding with friction at the debonded interface. On a basis of the minimum complementary energy principle, an expression for the energy release rate G was derived to explore the interfacial fracture properties. An interfacial debonding crite- rion G≥Γi was introduced to determine the critical debond length and the bridging law. Numerical calculation results for fi- ber-reinforced composite SCS-6/Ti-6Al-4V were compared with those obtained by using the shear-lag models. 展开更多
关键词 Fiber pull-out Energy release rate Bridging law Fiber-reinforced composites
下载PDF
Pull-out Behaviour of Axially Loaded Screwed-in Threaded Rods Embedded in CLT Elements: Experimental Study
10
作者 Huifeng Yang Junfeng Ji +3 位作者 Haotian Tao Benkai Shi Junbin Hu Bo Wen 《Journal of Renewable Materials》 SCIE EI 2022年第1期105-117,共13页
Experimental investigation on the pull-out behaviour,including the withdrawal capacity,slip stiffness and inter-facial shear stress,of axially loaded screwed-in threaded rod embedded in cross laminated timber(CLT)was ... Experimental investigation on the pull-out behaviour,including the withdrawal capacity,slip stiffness and inter-facial shear stress,of axially loaded screwed-in threaded rod embedded in cross laminated timber(CLT)was con-ducted.Specimens with varying embedment length and different number of threaded rods were tested in this study.To prevent premature splitting failure of timber,some specimens were reinforced in the direction perpen-dicular to the timber grain with self-tapping screws.Test results showed that the screwed-in threaded rod con-nections exhibited good pull-out behaviour with high withdrawal capacity and slip stiffness.Within a certain range,the withdrawal capacity increases considerably with the increase of embedment length,while the average interfacial shear stress shows the opposite tendency.The self-tapping screws played an important role on reducing the splitting of the timber and improving the withdrawal capacity and slip stiffness of the screwed-in threaded rod.Additionally,for the specimens with self-tapping screw reinforcements,the improvement of withdrawal capacity and stiffness when increasing the number of threaded rods are much more obvious than that of the speci-mens without the self-tapping screws,due to the change of failure modes. 展开更多
关键词 Threaded rods screwed-in pull-out behaviour timber structure experimental study
下载PDF
Study on Single-fiber Pull-out Method for Evaluating Interfacial Strength in CFRP
11
作者 Yudong, H. Zhiqian, Zh. +1 位作者 Lixun, L. Qiwei, L. 《High Technology Letters》 EI CAS 1995年第1期105-108,共4页
Single-fiber pull-out testing (SFPOT) methods are frequently used to evaluate the interfacial adhesion between fiber and matrix in composite materials. To make such pull-out measurements, however, the length of embedd... Single-fiber pull-out testing (SFPOT) methods are frequently used to evaluate the interfacial adhesion between fiber and matrix in composite materials. To make such pull-out measurements, however, the length of embedded fiber must be small enough so that the fiber does not break before it is pulled freely. This is difficult to achieve by conventional methods with fibers of small diameter, such as the carbon fibers. In this paper, a fiber pull-out experiment is described. Specialized apparatus in our laboratory, as well as this technique for sample preparation are discussed in detail. The interfacial shear strength of carbon fiber/resin matrix composites is analyzed quantitatively by using the finite-element method. The SFPOT system has been proved to be an available means for the study of interfacial properties for carbon fiber/resin matrix composites. 展开更多
关键词 Carbon fiber Composite materials Interfacial shear strength Single-fiber pull-out
下载PDF
Investigating Earth Reaction to Pull-Out Process of Frictional Rock Bolts Using Distinct Element Method
12
作者 Mohammad Sadegh Ayyoobi Arash Refahi 《Open Journal of Geology》 2020年第8期851-862,共12页
The reaction of earth to pull-out process of frictional rock bolts was here modeled by the distinct element method (DEM). Ten frictional bolts were prepared;the expanding shells of five bolts included convex edges and... The reaction of earth to pull-out process of frictional rock bolts was here modeled by the distinct element method (DEM). Ten frictional bolts were prepared;the expanding shells of five bolts included convex edges and the others had the shells with concave bits. The strength of bolts was measured by applying a standard pull-out test;the results confirmed that the strength of shells with convex edges was remarkably more than the strength of other shells. Furthermore, a two-dimensional DEM model of the test was developed by a particle flow code;the obtained results showed that the reaction of rock particles to the contacts occurring between the convex edges and earth was considerably more than those of the concave bits. In the other words, the convex edges transferred the pull-out force into a large area of the surrounded rock, causing these bolts to have the highest resistance against earth movements. 展开更多
关键词 Frictional Rock Bolt pull-out Test Distinct Element Method Particle Flow Code
下载PDF
Prediction of a maximum pull-out load of anchor bolts using an optimal combination model
13
作者 Ma Wenjie Wang Binglong +1 位作者 Wang Xu Wang Bolin 《Journal of Southeast University(English Edition)》 EI CAS 2021年第2期199-208,共10页
The mixed model of improved exponential and power function and unequal interval gray GM(1,1)model have poor accuracy in predicting the maximum pull-out load of anchor bolts.An optimal combination model was derived usi... The mixed model of improved exponential and power function and unequal interval gray GM(1,1)model have poor accuracy in predicting the maximum pull-out load of anchor bolts.An optimal combination model was derived using the optimally weighted combination theory and the minimum sum of logarithmic squared errors as the objective function.Two typical anchor bolt pull-out engineering cases were selected to compare the performance of the proposed model with those of existing ones.Results showed that the optimal combination model was suitable not only for the slow P-s curve but also for the steep P-s curve.Its accuracy and stable reliability,as well as its prediction capability classification,were better than those of the other prediction models.Therefore,the optimal combination model is an effective processing method for predicting the maximum pull-out load of anchor bolts according to measured data. 展开更多
关键词 anchor bolt maximum pull-out load mixed model of improved exponential and power function(MIEPF)model unequal interval gray GM(1 1)model optimal combination model
下载PDF
Nature of the Pull-out System of Carbon Nanorope/Polyethylene Composite and Twisting Effect on Interfacial Behavior
14
作者 尚军军 杨庆生 LU Yubin 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2017年第3期713-719,共7页
The nature of the pull-out system of carbon nanorope/polyethylene(CNRP/PE) composite is studied by using molecular dynamics approach. The deformation of the CNRP/PE composites in pull-out process is exhibited. The i... The nature of the pull-out system of carbon nanorope/polyethylene(CNRP/PE) composite is studied by using molecular dynamics approach. The deformation of the CNRP/PE composites in pull-out process is exhibited. The influence of twisting deformation on the interfacial interaction of the composites is investigated. The results show that the energy of the pull-out system is conserved; and the interfacial bonding is weak resulting in a sliding failure of the CNRP inside PE matrix. 展开更多
关键词 carbon nanorope nano-composite pull-out system fracture mechanism
下载PDF
Analysis of Pull-Out Behaviour of Straight and Hooked End Steel Fibres
15
作者 Sadoon Abdallah David W. A. Rees 《Engineering(科研)》 2019年第6期332-341,共10页
The effective utilisation of steel fibre reinforced concrete (SFRC) requires in-depth and detailed understanding of bonding mechanisms governing the tensile behaviour. In response to this demand, this study presents a... The effective utilisation of steel fibre reinforced concrete (SFRC) requires in-depth and detailed understanding of bonding mechanisms governing the tensile behaviour. In response to this demand, this study presents an empirical description of the axial force required to pull out a hooked end steel fibre from a cementitious matrix. It is based upon consistent experimental tests that show the force versus displacement plot is formed from a sequence of events in which partial and full debonding at the interface is followed by bending of the hook knee to raise the force to its maximum. A loss of peak force occurs with the reversed plasticity involved in a full straightening of the fibre that precedes the rapid sliding to its full removal under a falling force. The stages are assembled in the said order with a piecewise connection between linear segments and a curve of exponential decay. A power law can be introduced to describe the knee bending stage if preferred. The normalised co-ordinates were adopted for the simple mathematical discontinuous function of the full pull-out process. Normalising force and displacement for hooked fibre is based upon the maximum values found for straight fibre pull out. This would apply to an overall embedded length of unity and a unit peak force for a full debonding of straight fibre in similar materials. For hooked fibre the normalised co-ordinates given refer to the initiation and duration of each event to be tabulated at fractions of the embedded length with multiples of that force. Such predictions are seen to be in good agreement with average pull-out response curves. 展开更多
关键词 pull-out Behaviour Plastic HINGE Mechanical ANCHORAGE Hooked END FIBRE Analytical FORMULATION
下载PDF
移植肌腱与半月板后根吻合联合Pull-out法重建半月板后根
16
作者 刘守东 谢洪彬 +3 位作者 单森 刘南伯 王勃 刘慧莉 《实用骨科杂志》 2022年第9期842-847,共6页
目的探讨移植肌腱与半月板后根吻合联合Pull-out法(肌腱与缝线经胫骨骨道拉出)固定重建半月板后根的临床效果。方法回顾分析2016年1月至2020年12月期间应用移植肌腱与半月板后根吻合联合Pull-out法重建半月板后根(肌腱移植组)27例与单纯... 目的探讨移植肌腱与半月板后根吻合联合Pull-out法(肌腱与缝线经胫骨骨道拉出)固定重建半月板后根的临床效果。方法回顾分析2016年1月至2020年12月期间应用移植肌腱与半月板后根吻合联合Pull-out法重建半月板后根(肌腱移植组)27例与单纯Pull-out法(单纯组)23例,共50例,其中男29例,女21例;年龄23~67岁,平均(51.4±14.5)岁。比较两组术前与术后Lysholm评分、国际膝关节文献委员会(international knee documentation committee,IKDC)、MRI及X线影像表现。结果术后随访12~17个月,平均(14.88±1.69)个月。肌腱移植组与单纯组Lysholm评分、IKDC评分MRI半月板内侧移位距离、膝关节X线内侧间隙、MRI半月板后根影像结果比较,差异有统计学意义(P<0.05)。结论通过移植肌腱与半月板后根吻合联合Pull-out法能为半月板提供双重牵引复位张力,半月板复位缝合重建良好;经胫骨骨道固定符合生理解剖及生物力学要求,移植肌腱与半月板后根腱性愈合能力更强,骨道内腱骨愈合生物力学强度更高,可有效维持半月板环形张力维持膝关节稳定性,恢复正常膝关节功能,降低膝关节退变发生率,是一种可靠的治疗方式。 展开更多
关键词 半月板后根 移植肌腱 pull-out 胫骨骨道 重建
下载PDF
Comparison of the Pull-out Strength Between a Novel Micro-dynamic Pedicle Screw and a Traditional Pedicle Screw by Using Pull Out Test and Micro-CT
17
作者 Lei Qian Weidong Cheng Jun Ouyang 《医用生物力学》 EI CAS CSCD 北大核心 2019年第A01期56-56,共1页
Objective To investigate the effectiveness of the micro-dynamic pedicle screw for the prevention of loosening between the screw and bone surface in lumbar spinal fusion.For this evaluation,the peek pull-out force(PPF)... Objective To investigate the effectiveness of the micro-dynamic pedicle screw for the prevention of loosening between the screw and bone surface in lumbar spinal fusion.For this evaluation,the peek pull-out force(PPF)after fatigue resistance testing at different cycles and semidiameter of screw insertion area of micro-CT image was compared between the micro-dynamic and traditional pedicle screws.Methods Forty lumbar vertebrae received a traditional pedicle screw on one side and a micro-dynamic pedicle screw on the other side as follows:15 vertebrae underwent instant pull-out testing(group A,traditional vs.group B,micro-dynamic);15 vertebrae underwent pull-out test after 5000-cyclic fatigue loading(group C,traditional vs.group D,micro-dynamic);and 10 vertebrae underwent pull-out test after 10000-cyclic fatigue loading(group E,traditional vs.group F,micro-dynamic).All vertebrae that after fatigue loading were scanned by using micro-ct to check the semidiameter of screw insertion area.The PPF,normalized PPF(PPFn),bone mineral density(BMD)and diameter of screw insertion area were compared between all groups.Results The BMD showed a weak significant correlation with PPF(r=0.252,P=0.024).The PPF in groups A and B(P=0.485),and groups C and D(P=0.184)did not show significant difference.However,the PPF in group F was significantly greater than that measured in group E(P=0.005).The PPFn of groups A,C,and E significantly decreased as the number of cycles increased(P=0.015).Meanwhile,the PPFn of groups B,D,and F remained consistent regardless of the number of cycles(P=0.367). The semidiameter of traditional pedicle screw insertion area was significantly larger than that of micro-dynamic pedicle screw insertion area(P<0.001).Conclusions This study compared the performance of a micro-dynamic pedicle screw versus that of a traditional pedicle screw using pull-out testing and micro-CT.The results showed that the micro-dynamic pedicle screw provides similar resistance in lowcycle fatigue testing and favorable resistance in high-cycle fatigue testing versus the traditional pedicle screw.The micro-dynamic pedicle screw provides stronger fixation stability versus the traditional pedicle screw,especially in high-cyclic fatigue loading condition versus the traditional pedicle screws. 展开更多
关键词 micro-dynamic pedicle screw PULL OUT STRENGTH MICRO CT
下载PDF
循环张拉作用下新型多节泡土钉抗拔性能现场试验研究 被引量:1
18
作者 叶新宇 时一帆 +3 位作者 李煜 张升 田奔 刘蔚 《铁道科学与工程学报》 EI CAS CSCD 北大核心 2024年第3期1037-1046,共10页
新型多节泡土钉具有拉拔硬化特征,相比传统土钉,其在土质边坡中抗拔性能更优。为了探究实际工况条件下新型多节泡土钉的边坡加固性能,并与传统土钉进行比较,开展7组新型多节泡土钉及传统土钉现场循环张拉试验,研究注浆工艺、节泡间距及... 新型多节泡土钉具有拉拔硬化特征,相比传统土钉,其在土质边坡中抗拔性能更优。为了探究实际工况条件下新型多节泡土钉的边坡加固性能,并与传统土钉进行比较,开展7组新型多节泡土钉及传统土钉现场循环张拉试验,研究注浆工艺、节泡间距及埋深对土钉抗拔力及其发挥速率的影响规律,进而探明了每一循环下土钉弹、塑性拉拔位移占比,并分析其内在机理。试验结果表明:循环张拉作用下,注浆工艺对土钉的抗拔力影响显著,采用改进式压密注浆工艺和直接压密注浆工艺的土钉抗拔力远远超出传统注浆工艺,且初期的拉拔硬化现象更明显。采用改进式压密注浆工艺的土钉抗拔力发挥速率最快,直接压密注浆工艺次之,传统注浆工艺最小。从总体趋势上看,新型多节泡土钉抗拔力发挥速率在降低,传统土钉抗拔力发挥速率在升高。采用改进式压密注浆工艺虽然不能提升土钉弹性拉拔位移的占比,却能显著提高极限抗拔力;节泡间距对多节泡土钉抗拔力和抗拔力发挥速率影响较小,主要受到土钉周围土体强度的影响;埋深影响多节泡土钉的极限抗拔力,埋深越大,极限抗拔力和初始抗拔力发挥速率越大,同时抗拔力发挥速率随拉拔位移递减的趋势也更加明显。研究成果对提高新型多节泡土钉加固性能和优化工程应用提供指导。 展开更多
关键词 土钉 拉拔硬化 循环张拉 多节泡 现场试验
下载PDF
BFRP筋回收轮胎钢纤维混凝土黏结性能分析 被引量:1
19
作者 范小春 黄祎晨 +1 位作者 张澳 徐伟 《东南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2024年第2期389-397,共9页
对玄武岩纤维增强复合材料(BFRP)筋在回收轮胎钢纤维(RTSF)混凝土中的黏结性能进行了试验和分析研究.对不同RTSF体积掺量、BFRP筋直径和嵌入长度的试件进行了拉拔试验,研究其对黏结破坏模式、黏结滑移响应和黏结强度的影响,并提出了BFRP... 对玄武岩纤维增强复合材料(BFRP)筋在回收轮胎钢纤维(RTSF)混凝土中的黏结性能进行了试验和分析研究.对不同RTSF体积掺量、BFRP筋直径和嵌入长度的试件进行了拉拔试验,研究其对黏结破坏模式、黏结滑移响应和黏结强度的影响,并提出了BFRP筋RTSF混凝土的黏结滑移理论模型.结果表明:BFRP筋RTSF混凝土黏结破坏类型包括拔出破坏、劈裂破坏以及拔出且劈裂破坏;BFRP筋直径对黏结破坏模式无显著影响,而RTSF体积掺量、BFRP筋直径和嵌入长度均对黏结强度有较大影响,且RTSF体积掺量与极限黏结强度呈正相关,BFRP筋直径和嵌入长度对其影响与之相反;当RTSF体积掺量从0增大至1.5%时,其极限黏结强度最大可提高约23.87%.与已有模型相比,所提出的黏结滑移理论模型对BFRP筋RTSF混凝土的黏结滑移曲线具有更高的拟合精度. 展开更多
关键词 BFRP筋 回收轮胎钢纤维(RTSF)混凝土 拉拔试验 黏结应力-滑移曲线
下载PDF
玄武岩微筋对磷酸镁修补砂浆弯曲性能的增强增韧效应研究
20
作者 李伟 谢剑 佟成龙 《材料导报》 EI CAS CSCD 北大核心 2024年第17期32-40,共9页
为了探究玄武岩微筋(Basalt minibar)对磷酸镁修补砂浆(MPCRM)的增强增韧改性效果,通过四点弯曲试验分析纤维类型、纤维掺量、基体水胶比及养护条件对MPCRM弯拉强度和弯曲韧性的影响规律。试验结果表明:玄武岩微筋对MPCRM的弯曲增强增... 为了探究玄武岩微筋(Basalt minibar)对磷酸镁修补砂浆(MPCRM)的增强增韧改性效果,通过四点弯曲试验分析纤维类型、纤维掺量、基体水胶比及养护条件对MPCRM弯拉强度和弯曲韧性的影响规律。试验结果表明:玄武岩微筋对MPCRM的弯曲增强增韧性能优越,且其增韧效果优于玄武岩单丝纤维;当玄武岩微筋掺量不低于1.0%(体积分数)时,MPCRM弯拉强度和弯曲韧性均随着玄武岩微筋掺量增加而提高;随着水胶比提高,玄武岩微筋增强MPCRM的弯曲韧性降低,弯拉强度先增加后减小,水胶比为0.18和体积掺量为1.5%的玄武岩微筋增强MPCRM的弯拉强度最大;掺入玄武岩微筋能够部分弥补低温养护MPCRM的受冻损伤。 展开更多
关键词 磷酸镁修补砂浆(MPCRM) 玄武岩微筋 拔出功 弯曲韧性 低温养护
下载PDF
上一页 1 2 86 下一页 到第
使用帮助 返回顶部