期刊文献+
共找到4,808篇文章
< 1 2 241 >
每页显示 20 50 100
Unveiling sinus venosus atrial septal defect and partial anomalous pulmonary venous return in an elderly patient
1
作者 Cristina M Font Anamarys Blanco Fernandez Dinesh Kadariya 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2024年第4期462-464,共3页
Sinus venosus defect(SVD) accounts for 4%–11% of all atrial septal defects(ASD) and may present with dyspnea, heart failure(HF), palpitations, or angina.^[1] The malformation typically involves an interatrial communi... Sinus venosus defect(SVD) accounts for 4%–11% of all atrial septal defects(ASD) and may present with dyspnea, heart failure(HF), palpitations, or angina.^[1] The malformation typically involves an interatrial communication due to a deficiency in the common wall connecting the right pulmonary veins and the superior vena cava(SVC) and often accompanies anomalous pulmonary venous connection of some or all of the pulmonary veins. 展开更多
关键词 ATRIAL septal VENOUS
下载PDF
Surgical Repair of Ventricular Septal Defect in Neonates: Indications and Outcomes
2
作者 Jae Hong Lee Sungkyu Cho +6 位作者 Jae Gun Kwak Hye Won Kwon Woong-Han Kim Mi Kyoung Song Sang-Yun Lee Gi Beom Kim Eun Jung Bae 《Congenital Heart Disease》 SCIE 2024年第1期69-83,共15页
Background:The optimal surgical timing and clinical outcomes of ventricular septal defect(VSD)closure in neo-nates remain unclear.We aimed to evaluate the clinical outcomes of VSD closure in neonates(age≤30 days).Met... Background:The optimal surgical timing and clinical outcomes of ventricular septal defect(VSD)closure in neo-nates remain unclear.We aimed to evaluate the clinical outcomes of VSD closure in neonates(age≤30 days).Methods:We retrospectively reviewed 50 consecutive neonates who underwent VSD closure for isolated VSDs between August 2003 and June 2021.Indications for the procedure included congestive heart failure/failure to thrive and pulmonary hypertension.Major adverse events(MAEs)were defined as the composite of all-cause mortality,reoperation,persistent atrioventricular block,and significant(≥grade 2)valvular dysfunction.Results:The median age and body weight at operation were 26.0 days(interquartile range[IQR],18.8–28.3)and 3.7 kg(IQR,3.3–4.2),respectively.The median follow-up duration was 110.4 months(IQR,56.8–165.0).Seven patients required preoperative respiratory support,andfive had significant(≥grade 2)preoperative valvular dysfunction.One early mortality occurred due to irreversible cardiogenic shock;no late mortality was observed.One reopera-tion was due to hemodynamically significant residual VSD at 103.8 months postoperatively.The overall survival,freedom from reoperation,and freedom from MAE at 15-years were 98.0%,96.3%,and 94.4%,respectively.Pre-operative mechanical ventilation was associated with a longer duration of postoperative mechanical ventilation(p<0.001)and a longer length of intensive care unit stay(p<0.001).Conclusions:VSD closure with favorable outcomes without morbidities is feasible even in neonates.However,neonates requiring preoperative respiratory support may require careful postoperative management considering the long-term postoperative risks.Overall,surgical VSD closure might be indicated earlier in neonates with respiratory compromise. 展开更多
关键词 Ventricular septal defect NEONATE early surgery neonatal surgery
下载PDF
Impact of Atrial Septal Defect Closure on Mortality in Older Patients
3
作者 Sipawath Khamplod Yodying Kaolawanich +1 位作者 Khemajira Karaketklang Nithima Ratanasit 《Congenital Heart Disease》 SCIE 2024年第1期93-105,共13页
Background:Atrial septal defect(ASD)is a common form of adult congenital heart disease that can lead to long-term adverse outcomes if left untreated.Early closure of ASD has been associated with excellent outcomes and... Background:Atrial septal defect(ASD)is a common form of adult congenital heart disease that can lead to long-term adverse outcomes if left untreated.Early closure of ASD has been associated with excellent outcomes and lower complication rates.However,there is limited evidence regarding the prognosis of ASD closure in older adults.This study aims to evaluate the mortality rates in older ASD patients with and without closure.Methods:A retrospective cohort study was conducted on patients aged 40 years or older with ASD between 2001 and 2017.Patients were followed up to assess all-cause mortality.Univariable and multivariable analyses were performed to identify the predictors of mortality.A p-value of<0.05 was considered statistically significant.Results:The cohort consisted of 450 patients(mean age 56.6±10.4 years,77.3%female),with 66%aged between 40 and 60 years,and 34%over 60 years.Within the cohort,299 underwent ASD closure(201 with transcatheter and 98 with surgical closure).During the median follow-up duration of 7.9 years,51 patients died.The unadjusted cumulative 10-year rate of mortality was 3%in patients with ASD closure,and 28%in patients without ASD closure(log-rank p<0.001).Multivariable analysis revealed that age(hazard ratio[HR]1.04,95%confidence interval[CI]1.006–1.06,p=0.01),NYHA class(HR 2.75,95%CI 1.63–4.62,p<0.001),blood urea nitrogen(BUN)(HR 1.07,95%CI 1.03–1.12,p<0.001),right ventricular systolic pressure(RVSP)(HR 1.07,95%CI 1.003–1.04,p=0.01),and lack of ASD closure(HR 15.12,95%CI 5.63–40.59,p<0.001)were independently associated with mortality.Conclusion:ASD closure demonstrated favorable outcomes in older patients.Age,NYHA class,BUN,RVSP,and lack of ASD closure were identified as independent factors linked to mortality in this population. 展开更多
关键词 Atrial septal defect congenital heart disease defect closure long-term survival MORTALITY
下载PDF
Reliability of Echocardiographic Pulmonary Vascular Resistance to Screen for the New Definition of Precapillary Pulmonary Hypertension in Uncorrected Secundum Atrial Septal Defect
4
作者 Risalina Myrtha Hasanah Mumpuni +3 位作者 Real Kusumanjaya Marsam Dyah Wulan Anggrahini Anggoro Budi Hartopo Lucia Kris Dinarti 《Congenital Heart Disease》 SCIE 2024年第3期315-324,共10页
Background and Objective:The most feared complication of uncorrected secundum Atrial Septal Defect(ASD)is pulmonary arterial hypertension(PAH).Pulmonary vascular resistance(PVR)is crucial in detecting precapil-lary pu... Background and Objective:The most feared complication of uncorrected secundum Atrial Septal Defect(ASD)is pulmonary arterial hypertension(PAH).Pulmonary vascular resistance(PVR)is crucial in detecting precapil-lary pulmonary hypertension(PH)to guide the need for PAH-specific therapy.There is a change in the cut-off value of PVR according to the recently updated PH guideline.How echocardiographic PVR(PVRecho)correlates to PVR by right heart catheterization(RHC)(PVRcath)according to the new guidelines has not been known.The aim of this study is to determine the reliability of PVRecho in detecting PAH in Uncorrected Ostium Secundum ASD based on the current updated guideline and to help screen the high PVR group.Methods:429 ostium secun-dum ASD in the COngenital HeARt Disease in Adult and Pulmonary Hypertension(COHARD-PH)registry was divided into three groups according to the PVR.PVRecho was calculated using Abbas’Formula and compared the its gold standard,the PVRcath.The correlation between the two methods was analyzed.The Bland-Altman plot was used to analyze the agreement between the two methods.Receiver operating characteristics(ROC)analysis was used to determine the PVRecho cut-off value for high PVR.Results:The majority of the population(63.5%)had high PVR.Female gender dominated the study population(84%).PVR_(echo) was significantly correlated with PVRcath(r=0.6225,p<0.0001).Bland-Altman plot among all groups and in subgroups analysis showed a wide range of agreement.PVRecho underestimated PVRcath 5.124 WU.In subgroup analysis,PVRecho overestimated PVRcath 0.35 WU in those with PVR<2 WU.In the second and third groups,PVR_(echo) underestimated PVRcath 0.52 and 10.77 WU,respectively.Conclusion:PVRecho is reliable in predicting high PVR in uncorrected secun-dum ASD.However,there is a wide range of agreement.PVR_(echo) cut-off value of>1.62 WU showed good dis-criminatory power in determining high PVR. 展开更多
关键词 Pulmonary vascular resistance atrial septal defect ECHOCARDIOGRAPHY
下载PDF
Effects of atrial septal defects on the cardiac conduction system
5
作者 Jin-Hua Kang Hong-Yan Wu Wen-Jie Long 《World Journal of Clinical Cases》 SCIE 2024年第35期6770-6774,共5页
The case report presented in this edition by Mu et al.The report presents a case of atrial septal defect(ASD)associated with electrocardiographic changes,noting that the crochetage sign resolved after Selective His Bu... The case report presented in this edition by Mu et al.The report presents a case of atrial septal defect(ASD)associated with electrocardiographic changes,noting that the crochetage sign resolved after Selective His Bundle Pacing(S-HBP)without requiring surgical closure.The mechanisms behind the appearance and resolution of the crochetage sign remain unclear.The authors observed the dis-appearance of the crochetage sign post-S-HBP,suggesting a possible correlation between these specific R waves and the cardiac conduction system.This editorial aims to explore various types of ASD and their relationship with the cardiac con-duction system,highlighting the diagnostic significance of the crochetage sign in ASD. 展开更多
关键词 Atrial septal defects Cardiac conduction system Crochetage sign ELECTROCARDIOGRAM Selective His bundle pacing
下载PDF
Intelligent diagnosis of atrial septal defect in children using echocardiography with deep learning
6
作者 Yiman LIU Size HOU +7 位作者 Xiaoxiang HAN Tongtong LIANG Menghan HU Xin WANG Wei GU Yuqi ZHANG Qingli LI Jiangang CHEN 《虚拟现实与智能硬件(中英文)》 EI 2024年第3期217-225,共9页
Background Atrial septal defect(ASD)is one of the most common congenital heart diseases.The diagnosis of ASD via transthoracic echocardiography is subjective and time-consuming.Methods The objective of this study was ... Background Atrial septal defect(ASD)is one of the most common congenital heart diseases.The diagnosis of ASD via transthoracic echocardiography is subjective and time-consuming.Methods The objective of this study was to evaluate the feasibility and accuracy of automatic detection of ASD in children based on color Doppler echocardiographic static images using end-to-end convolutional neural networks.The proposed depthwise separable convolution model identifies ASDs with static color Doppler images in a standard view.Among the standard views,we selected two echocardiographic views,i.e.,the subcostal sagittal view of the atrium septum and the low parasternal four-chamber view.The developed ASD detection system was validated using a training set consisting of 396 echocardiographic images corresponding to 198 cases.Additionally,an independent test dataset of 112 images corresponding to 56 cases was used,including 101 cases with ASDs and 153 cases with normal hearts.Results The average area under the receiver operating characteristic curve,recall,precision,specificity,F1-score,and accuracy of the proposed ASD detection model were 91.99,80.00,82.22,87.50,79.57,and 83.04,respectively.Conclusions The proposed model can accurately and automatically identify ASD,providing a strong foundation for the intelligent diagnosis of congenital heart diseases. 展开更多
关键词 Deep learning Atrial septal defect ECHOCARDIOGRAPHY
下载PDF
Isolated Ventricular Septal Defect: Ultrasound, Therapeutic and Evolutionary Aspects of 85 Cases in the Cardiology Department of the Ignace Deen National Hospital in Conakry
7
作者 Mamadou Bassirou Bah Amadou Diouldé Doumbouya +12 位作者 Elhdj Yaya Balde Mamadou Aliou Balde Alpha Kone Ibrahima Sory Sylla Mamadou Dian Bah Aboulaye Bah Mamadou Diallo Thierno Siradjo Balde Abdoulaye Camara Morlaye Soumaoro Ibrahima Sory Barry Souleymane Diakité Mamadou Dadhi Balde 《World Journal of Cardiovascular Diseases》 CAS 2024年第8期465-479,共15页
Introduction: Ventricular septal defect (VSD) is the most common congenital heart disease of all congenital heart defects. The aim of this study was to investigate the echographic, therapeutic and evolutionary aspects... Introduction: Ventricular septal defect (VSD) is the most common congenital heart disease of all congenital heart defects. The aim of this study was to investigate the echographic, therapeutic and evolutionary aspects of ventricular septal defects (VSD) in the general cardiology department of the Hôpital National Ignace Deen. Methods: A retrospective data collection was carried out from January 2018 to December 2023 including 85 cases of isolated IVC was performed. The variables studied were epidemiological, clinical, paraclinical, therapeutic and evolutionary. Results: Of the 320 patients seen during the study period for congenital heart disease, 85 (26.556%) were isolated IVCs. Age at diagnosis ranged from 3 months to 16 years, with an average age of 3.59 years. The most represented ethnic group was the Fulani (50.58%). The 8.24% came from consanguineous marriage versus 22.35%. 91.76% of children had a history of bronchitis. The most common clinical signs found were systolic murmur (90.58%), growth retardation (51.76%). Only 4 cases (4.70%) had a malformation associated with IVC represented by DiGeorges disease (2.35%) and trisomy 21 (2.35%). Nearly half the patients had type IIb VIC (44.71%). The other half were represented by type 1 (18.82%), type IIa (20%), type III (10.59%) and type IV (5.88%). According to site more than two-thirds of VICs (71.64%) were perimembranous in location, followed by infundibular (16.47%) and muscular (11.76%) VICs. In our study 55.29% presented an indication for both surgical intervention and medical treatment, while 16.47% required only medical treatment. In contrast, 28.23% were placed under exclusive surveillance. Of the 47 patients for whom surgery was indicated, 29 (61.17%) underwent surgical repair, while 18 (38.83%) were awaiting confirmation for surgery. Conclusion: VIC is the most common congenital heart disease. An early detection strategy and the establishment of specialized centers could improve the outcome of these children. 展开更多
关键词 Ventricular septal Defect Congenital Heart Disease Ignace Deen
下载PDF
Genetic Analysis of Variants of the MYH6 Gene Promoter in Congenital Atrial Septal Defects 被引量:1
8
作者 Ji-Yang Zuo Huan-Xin Chen +2 位作者 Zhi-Gang Liu Qin Yang Guo-Wei He 《Congenital Heart Disease》 SCIE 2023年第1期7-21,共15页
Background:Atrial septal defect(ASD)is one of the common congenital heart diseases.The MYH6 gene has a critical role in cardiac development but the role of MYH6 promoter variants in patients with ASD has not been expl... Background:Atrial septal defect(ASD)is one of the common congenital heart diseases.The MYH6 gene has a critical role in cardiac development but the role of MYH6 promoter variants in patients with ASD has not been explored.Methods:In 613 subjects including 320 ASD patients,we investigated the MYH6 gene promoter variants and verified the effect on gene expression by using cellular functional experiments and bioinformatics analysis.Results:Eleven variants were identified in the MYH6 gene promoter,of which four variants were found only in ASD patients,and two variants(g.3434G>C and g.4524C>T)were identified for the first time.Cellular functional experiments indicated that all four variants reduced the transcriptional activity of the MYH6 gene promoter(p<0.05).Subsequent analysis through the JASPAR(A database of transcription factor binding profiles)suggests that these variants may alter transcription factor binding sites,which may in turn lead to changes in myocardin subunit expression and ASD formation.Conclusions:Our study for the first time focuses on variants in the promoter region of the MYH6 gene in Chinese patients with ASD and the discovered variants have functional significance.The study provides new insights in the role of the MYH6 gene promoter region to better understand the genetic basis of ASD formation and facilitates clinical diagnosis. 展开更多
关键词 Atrial septal defect MYH6 GENETIC VARIANTS congenital heart disease
下载PDF
Transcatheter Ventricular Septal Defect Closure with Nit-Occlud LêVSD Device—Five Years’Experience and Literature Review
9
作者 Ivana B.Cerović Vladislav A.Vukomanović +6 位作者 Jovan Lj.Košutić Mila S.Stajević Sanja S.Ninić Saša S.Popović Ivan D.Dizdarević Staša D.Krasić Sergej M.Prijić 《Congenital Heart Disease》 SCIE 2023年第3期361-371,共11页
Introduction:Transcatheter closure is an alternative to ventricular septal defect(VSD)occlusion surgery.Nit-Occlud LêVSD coil is a new device yet to be evaluated.The study aimed to evaluate immediate and midterm ... Introduction:Transcatheter closure is an alternative to ventricular septal defect(VSD)occlusion surgery.Nit-Occlud LêVSD coil is a new device yet to be evaluated.The study aimed to evaluate immediate and midterm results after transcatheter closure with the Nit-Occlud LêVSD device.Methods:The retrospective analysis included 30 patients with VSD referred for closure during the period from October 2015 to December 2020.Results:At the time of intervention,the patients’mean age and body weights were 7.5±5.6 years and 29.3±19.1 kg.The majority of the defects had perimembranous location(24/30),four defects had muscular and two outlet subaortic position.The mean effective right-side diameter of the VSDs was 3.6±1.3 mm.Single ventricular fibrillation,device embolization,and hemolysis developed in different patients and were successfully treated.None of the patients had a complete atrioventricular block.The coil was successfully placed in 25/30(83.3%)patients.The majority of the devices were 10 mm×6 mm(11/25)and 12 mm×8 mm(8/25)in size.Two patients required the implantation of a second device.The follow-up period was 2.1±1.4 years.Complete VSD closure was achieved in 48%of cases immediately after the intervention,74%during 2.1±1.6 months after the procedure,and 81%over follow-up.The remaining patients had a trivial residual defect.During the follow-up,approximately one-third of patients developed trivial aortic and mitral valve regurgitation,and half of the patients acquired trace/mild tricuspid regurgitation.Standardized(z-score)left ventricular end-diastolic diameter(0.15±0.37 vs.0.92±0.82,p=0.005)and left atrium dimension(0.47±0.58 vs.1.89±1.11,p=0.005),as well as the left atrium to aortic root ratio(1.2±0.1 vs.1.4±0.2,p=0.005)showed a significant decrease over follow-up related to the period before intervention.Conclusion:Intervention with Nit-OccludLêVSD coil showed appropriate results regarding VSD closure rate,complications,and chamber remodeling.The introduction of this device into clinical practice is a significant step forward in transcatheter perimembranous VSD occlusion. 展开更多
关键词 Ventricular septal defect TRANSCATHETER DEVICE children
下载PDF
Mortality Rates of Ventricular Septal Defect for Children in Kazakhstan: Spatio-Temporal Epidemiological Appraisal
10
作者 Akkerbez Adilbekova Shukhrat Marassulov +2 位作者 Bakhytzhan Nurkeev Saken Kozhakhmetov Aikorkem Badambekova 《Congenital Heart Disease》 SCIE 2023年第4期447-459,共13页
Objective: The aim is to study the trends in ventricular septal defect (VSD) mortality in children in Kazakhstan.Methods: The retrospective study was done for the period 2011–2020. Descriptive and analytical methods ... Objective: The aim is to study the trends in ventricular septal defect (VSD) mortality in children in Kazakhstan.Methods: The retrospective study was done for the period 2011–2020. Descriptive and analytical methods of epidemiologywere applied. The universally acknowledged methodology used in sanitary statistics is used to calculatethe extensive, crude, and age-specific mortality rates. Results: Kazakhstan is thought to be seeing an increase inmortality from VSDs in children. As a result, this study for the years 2011 to 2020 was conducted to retrospectivelyassess data from the central registration of the Bureau of National Statistics that was available throughoutthe nation. Age-standardized mortality data were obtained and compared between age categories. It was shownthat 507 children died from this condition throughout the time period under study. The average annual standardizedmortality rate was 1.88 per 100,000 population and tended to decrease over time. The peak of mortality wasnoted at the age of up to 1 year, namely the neonatal period. Cartogram mortality rates were calculated usingstandardized indicators. Additionally, age-sex variations were taken into account when performing all calculations.Conclusion: In recent years, the death rate from VSD has declined from 1.5 to 0.6 per 100,000 people, withthe trend remaining constant (T = 1.4%, R^(2) = 0.5825). The analysis of mortality trends related to VSD is crucial inboth theoretical and practical aspects, as it enables early detection and treatment of VSDs. The findings of thisstudy will be valuable to public health authorities in developing a strategy to treat VSDs effectively. 展开更多
关键词 Ventricular septal defect children mortality geographical variation kazakhstan
下载PDF
Ventricular Septal Crypts:Remnants of Spontaneous Interventricular Defect Closure?
11
作者 Alberto Cresti Stefania Sparla +2 位作者 Stefania Stefanelli Andrea Picchi Ugo Limbruno 《Congenital Heart Disease》 SCIE 2023年第1期1-6,共6页
Background:Ventricular crypts are quite a common finding during cardiac imaging,but their etiology is unclear.A possible final result of a spontaneous ventricular septal defect closure has been supposed but never inve... Background:Ventricular crypts are quite a common finding during cardiac imaging,but their etiology is unclear.A possible final result of a spontaneous ventricular septal defect closure has been supposed but never investigated in earlier studies.Method:From January 1997 to December 2020,all newborns diagnosed to have a ventricular septal defect were prospectively entered in our database and those with an isolated defect were included in the study.Ventricular septal defects were classified into four types:perimembranous,trabecular muscular,inlet and outlet.A long-term follow up was performed in order to visualize the possible residual formation of a septal myocardial crypt.Results:A total of 376 isolated ventricular septal defects(314 muscular and 54 perimembranous,4 inlet,4 outlet)were detected.Follow up ranged from 1 to 23 years and showed that,among muscular type,a spontaneous closure occurred in 284(91%),26 did not close(8,28%),2 required surgical intervention(0,63%),3 were lost at follow up(0,95%).During this period,after spontaneous defect closure closure,20 crypts were found(6,4%).Conclusion:This study shows that a muscular ventricular septal defect may evolve in the 6.4%of cases in a residual septal crypt.Although septal crypts occur more frequently in patients affected by hypertrophic and hypertensive cardiomyopathy,they may also represent the evolution of a spontaneous closure of a muscular interventricular defect. 展开更多
关键词 Ventricular crypts ventricular septal defect cardiac imaging
下载PDF
“Treat-Repair-Treat”:Management of Left Main Coronary Compression by a Pulmonary Artery Aneurysm in a Patient with Atrial Septal Defect and Significant Pulmonary Hypertension
12
作者 Andrei George Iosifescu Roxana Enache +2 位作者 Ioana Marinică Corina Radu Vlad Anton Iliescu 《Congenital Heart Disease》 SCIE 2023年第1期67-72,共6页
Left main coronary compression syndrome(LMCS)may complicate pulmonary artery aneurysms(PAA),usually developed in the context of pulmonary arterial hypertension(PAH).We report the case of a 51-year-old female patient w... Left main coronary compression syndrome(LMCS)may complicate pulmonary artery aneurysms(PAA),usually developed in the context of pulmonary arterial hypertension(PAH).We report the case of a 51-year-old female patient with an atrial septal defect(unsuitable for device closure)complicated by a PAA generating a 90%left main stenosis.The significant PAH held us back from immediate surgery.After specific dual PAH-targeted therapy(sildenafil and bosentan),the atrial septal defect could be closed with a unidirectional valved patch;the PAAinduced LMCS was treated by reductive arterioplasty.The postoperative course was uneventful.Follow-up showed clinical improvement,but PAH treatment was still needed.After three months,coronary angiography showed only an insignificant residual left main stenosis,proving that reductive pulmonary arterioplasty was effective in treating LMCS.Any PAA requires further evaluation for LMCS,a dangerous but treatable complication.The“treat-repair-treat”strategy and shunt-closure with a unidirectional valved patch can both improve surgical prospects of LMCS with shunt-related PAH. 展开更多
关键词 Atrial septal defect pulmonary arterial hypertension pulmonary artery aneurysm left main coronary compression syndrome surgery unidirectional valved patch
下载PDF
The Effect of Atrial Septal Defect Closure on Cardiac Volumetric Changes in Adults, Transcatheter Versus Surgical Closure, a Pilot Cardiac Magnetic Resonance Study
13
作者 Amr Mansour Noha M.Gamal +3 位作者 Alaa M.Nady Amr Ibraheem Dalia M.Salah Khaled M.El-Maghraby 《Congenital Heart Disease》 SCIE 2023年第6期679-691,共13页
Background:Closure of an atrial septal defect(ASD)reduces right-side heart volumes by abolishing shunting with simultaneous improvement of the left ventricle(LV)filling and functions due to ventricular interdependence,... Background:Closure of an atrial septal defect(ASD)reduces right-side heart volumes by abolishing shunting with simultaneous improvement of the left ventricle(LV)filling and functions due to ventricular interdependence,thereby improving symptoms.Furthermore,studies conducted on atrial volume changes after ASD closure are limited.Cardiac magnetic resonance(CMR)is considered as the gold standard method for measuring cardiac volume and mass.Objective:We aimed to study the effect of transcatheter and surgical closure of secundum ASD on cardiac volumes and systolic functions as well as the fate of tricuspid regurgitation(TR),using CMR analysis.Methods:We prospectively enrolled 30 adult patients with isolated secundum ASD who were referred to ASD closure.CMR evaluation of cardiac chambers indexed volumes,systolic function,myocardial mass index,and tricuspid regurgitant fraction were done at before and 6 months after closure.Results:RV volumes decreased in both groups when compared to baseline(p-value 0.001),the device group had more reduction in volumes and more improvement in RV function after closure(p-value 0.001)when compared to the surgical arm.The changes in the RV mass index were insignificant between both groups(p-value 0.31).Functional TR improved to the same extent in both groups.Left ventricular end diastolic volume index(LVEDVI)and LV mass index increased sig-nificantly in both groups when compared to baseline in both groups but with no difference between groups p-value 0.01),left ventricular end systolic volume index(LVESVI)changes were insignificant.LV systolic function improved in patients who underwent device closure only(63.53±3.85 vs.67.13±4.34,p-value 0.01).There was a significant reduction in right atrial(RA)volumes and an insignificant decrease in left atrial(LA)volumes,with no difference between groups.Conclusion:Transcatheter and surgical secundum ASD closure resulted in volumetric changes in some cardiac chambers with better improvement in bi-ventricular systolic function in the transcatheter arm and no difference in the TR reduction between the two groups at 6 months follow-up by CMR. 展开更多
关键词 Atrial septal defect closure cardiac volumetric changes functional tricuspid regurgitation cardiac CMR
下载PDF
Outcomes of Transcatheter Closure in Outlet-Type Ventricular Septal Defect after 1 Year
14
作者 Supaporn Roymanee Nantawan Su-angka +4 位作者 Worakan Promphan Kanjarut Wongwaitaweewong Jirayut Jarutach Rujira Buntharikpornpun Pimpak Prachasilchai 《Congenital Heart Disease》 SCIE 2023年第2期169-182,共14页
Background:Ventricular septal defect(VSD)is the most common congenital heart disease.Transcatheter VSD closure is an effective treatment for patients with muscular and perimembranous VSD.However,there is a limit data ... Background:Ventricular septal defect(VSD)is the most common congenital heart disease.Transcatheter VSD closure is an effective treatment for patients with muscular and perimembranous VSD.However,there is a limit data for outlet VSD,especially impact to the aortic valve leaflet after transcatheter closure.This study aims to assess the outcomes of transcatheter closure of the outlet-type ventricular septal defect(OVSD)after 1 postoperative year.Methods:A retrospective study was performed including 50 patients who underwent transcatheter(n=25)and surgical(n=25)OVSD closure during the exact time frame at two medical centres.Results:The median age and body weight of patients in the transcatheter group were significantly higher than those of patients in the surgical group(7.0 vs.2.8 years;27.0 vs.11.4 kg;p<0.01).The defect size in the surgical group was significantly larger than that in the transcatheter group(5.0 vs.3.0 mm;p<0.01).All OVSD patients have successful transcatheter closure(100%)as effective as surgical closure.Less than small residual shunt was present 20%and 8%immediately after the procedure in the transcatheter and surgical groups(p=0.50),which decreased to 12%and 4%at the 1-year follow-up(p=0.61),respectively.No incidence of complete atrioventricular block and other complications was observed in both groups,and no significant differences were noted in the new onset or worsening of the aortic regurgitation in both groups(p=1.0).Conclusions:Transcatheter treatment could be effectively and safely achieved for OVSD closure at 1-year follow-up. 展开更多
关键词 Outlet ventricular septal defect aortic valve prolapse aortic regurgitation transcatheter closure OUTCOME INTERVENTION
下载PDF
Effects of General Anesthesia on the Results of Cardiac Catheterization in Pediatric Patients with Ventricular Septal Defect
15
作者 Kiyotaka Go Taichi Kato +5 位作者 Machiko Kito Yoshihito Morimoto Satoru Kawai Hidenori Yamamoto Yoshie Fukasawa Kazushi Yasuda 《Congenital Heart Disease》 SCIE 2023年第2期235-243,共9页
Background:There is no gold standard sedation method for pediatric cardiac catheterization.In congenital heart diseases with intracardiac shunts,hemodynamic parameters are prone to change depending on the ventilation ... Background:There is no gold standard sedation method for pediatric cardiac catheterization.In congenital heart diseases with intracardiac shunts,hemodynamic parameters are prone to change depending on the ventilation conditions and anesthetics,although few studies have examined these effects.The purpose of this study was to investigate the effects of two different sedation methods on the hemodynamic parameters.Methods:This study retrospectively evaluated consecutive patients with ventricular septal defect(VSD)below 1 year of age who underwent cardiac catheterization at Aichi Children’s Health and Medical Center,who were divided into age-and VSD diameter-matched general anesthesia(GA)and monitored anesthesia care(MAC)under the natural airway groups(n=40 each),for comparison of hemodynamic parameters.Results:In the GA group,arterial blood pH and arterial partial pressure of oxygen were significantly higher(p<0.01),whereas arterial partial pressure of carbon dioxide was significantly lower than in the MAC group(p<0.01).Mean pulmonary artery pressure(p<0.05)and systemic blood pressure(p<0.01)were lower in the GA group.Pulmonary vascular resistance index(p<0.01)and systemic vascular resistance index(p<0.01)were also significantly lower in the GA group than the MAC group.There were no significant differences in pulmonary blood flow index,systemic blood flow index,and pulmonary/systemic blood flow ratio between the two groups.Conclusions:Cardiac catheterization under GA in VSD patients results in different hemodynamic parameters compared to that under MAC.In particular,when using pulmonary artery pressure and pulmonary vascular resistance measured under GA for judgment regarding the surgical indications or perioperative management,consideration should be given to the fact that these parameters might be lower compared to those measured under MAC. 展开更多
关键词 Ventricular septal defect cardiac catheterization general anesthesia monitored anesthesia care
下载PDF
Effectiveness and Safety of Transcatheter Closure of Various Ventricular Septal Defects Using Second-Generation Amplatzer Duct Occluders
16
作者 Jianming Wang Qiguang Wang +3 位作者 Xiaotang Sheng Jingsong Geng Jiawang Xiao Xianyang Zhu 《Congenital Heart Disease》 SCIE 2023年第2期183-195,共13页
Objective:This study was designed to determine the long-term safety and efficacy of using the Amplatzer Duct Occluder II(ADO II)for the closure of various ventricular septal defects(VSDs).Methods:From January 2011 to ... Objective:This study was designed to determine the long-term safety and efficacy of using the Amplatzer Duct Occluder II(ADO II)for the closure of various ventricular septal defects(VSDs).Methods:From January 2011 to December 2019,selected VSD patients were treated through transcatheter intervention using ADO II occluders.The closure results and complications from 188 patients,involving 167 perimembranous ventricular septal defects(pmVSDs),9 intracristal VSDs,11 post surgery residual shunts and 1 post closure residual shunt with the mean outlet diameter3.1±0.8 mm under angiography,were enrolled in this study.Results:The success rate was 98.9%for all procedures.During the median 77-month follow-up period,no cases of complete atrioventricular block(cAVB),infective endocarditis or death occurred.One major adverse event(0.5%)was recorded:cerebrovascular accident occurred 1 day after the procedure in one patient who was transferred to the neurology department.The residual shunt rate was 44.6%,which was the most common minor adverse event.The cardiac conduction block rate was 4.3%.Specifically,one pmVSD patient developed intermittent LBBB during the 28-month follow-up.There were 3 patients(1.6%)with new-onset mild tricuspid insufficiency,and the insufficiency degree was stable during follow-up.There was no new-onset aortic insufficiency that occurred.Conclusions:Transcatheter closure of pmVSDs,some intracristal VSDs,some postsurgery or postclosure residual shunts using ADO II occluders were both safe and effective and yielded excellent long-term results in selected patients. 展开更多
关键词 Ventricular septal defects Amplatzer Duct Occluder II long-term follow-up transcatheter closure
下载PDF
A Sandwich Technique Employing Right Ventricular Incision to Repair Posterior Ventricular Septal Rupture with Right Ventricular Wall Dissection: A Case Report
17
作者 Daichi Sakurahara Koji Furukawa +4 位作者 Hirohito Ishii Shuhei Sakaguchi Katsuya Kawagoe Tomoaki Taniguchi Risa Meiri 《World Journal of Cardiovascular Surgery》 2023年第10期145-153,共9页
Background: Ventricular septal rupture (VSR) leading to right ventricular (RV) wall dissection is an extremely rare and life-threatening complication of inferior myocardial infarction (MI) with posterior VSR. Its rare... Background: Ventricular septal rupture (VSR) leading to right ventricular (RV) wall dissection is an extremely rare and life-threatening complication of inferior myocardial infarction (MI) with posterior VSR. Its rare incidence and complex pathology make it difficult to select the appropriate surgical procedures to prevent fatalities. Case Presentation: A 68-year-old woman was transferred to our hospital because of a post-infarction VSR 12 days after symptom onset. Short-axis image obtained using transthoracic echocardiography demonstrated a large posterior VSR. Moreover, the VSR was continuous, with a large echo-free space in the posterior wall of the right ventricle. Color echocardiography showed blood flowing into the echo-free space through the septal defect and blood flowing out into the RV lumen. Coronary angiography revealed complete occlusion of the second segment of the right coronary artery. Thus, dissection of the posterior wall of the right ventricle that continued into the RV lumen was considered to have been caused by the posterior VSR caused by an inferior MI. The patient underwent urgent surgery to repair the VSR using the sandwich double-patch technique by making a posterior RV incision that was repaired using a third patch. No additional procedure was required to block the flow from the cavity of the RV wall dissection into the RV lumen. Postoperative echocardiography and contrast-enhanced computed tomography demonstrated that the VSR was closed securely and the RV wall dissection was almost completely thrombosed. Conclusion: In this case, a patient with a posterior VSR and RV wall dissection was successfully treated using the sandwich double-patch technique with a posterior RV incision. No additional procedure may be needed for RV wall dissection when a secure VSR repair is complete;however, close follow-up is essential to improve the long-term prognosis. 展开更多
关键词 Ventricular septal Rupture Right Ventricular Wall Dissection Surgery Sandwich Technique Right Ventricular Incision
下载PDF
The Role of Transesophageal Echocardiography for Transcatheter Closure of Atrial Septal Defects with the Amplatzer Septal Occluder 被引量:1
18
作者 许迪 孔祥清 +3 位作者 杨荣 盛燕辉 曹克将 陆凤翔 《Journal of Nanjing Medical University》 2003年第3期110-115,共6页
Objective: To evaluate of the role of transesophageal echocardiography (TEE)in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. Methods:Sixty- two patients (10 to 55 years of age... Objective: To evaluate of the role of transesophageal echocardiography (TEE)in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. Methods:Sixty- two patients (10 to 55 years of age) were selected for percutaneous closure of ASD bytrans-esophageal echocardiography, which was also used to monitor the procedure, to select theappropriate size of the Amplatzer device, to verify its position, and to access the immediateresults of the procedure. During the follow-up, transthoracic echocardiography (TTE) or TEE was usedto evaluate the presence and magnitude of residual shunt (RS), device position, and right cardiacchamber diameters. Results: The mean ASD diameter by TTE ([19. 1 +- 5. 8] mm) was significantlysmaller (P< 0. 001) than the stretched diameter of the ASD (25. 1 +- 6. 4) mm. There are nosignificant differences between the TEE -measured value (23. 5+_6. 2) mm and the stretched diameterof the ASD (P > 0. 05). Due to proper patient selection all procedures were successful. There wasimmediate and complete closure in 61/62 patients, only one patients had trivial residual shunt.Follow- up was performed using TTE or TEE right after operation, 1 d, 1 month, 3 months, 6 monthsand yearly thereafter. Ail, patients remain asymptomatic without any clinical or technical problems.Conclusion: With the aid of TEE, percutaneous closure of ASD can be performed successfully, safely,and effectively. 展开更多
关键词 transesophageal echocardiography atrial septal defects amplatzer septaloccluder
下载PDF
Completed atrioventricular block induced by atrial septal defect occluder unfolding:A case report 被引量:1
19
作者 Chuan He Yang Zhou +2 位作者 Si-Si Tang Li-Hong Luo Kun Feng 《World Journal of Clinical Cases》 SCIE 2020年第22期5715-5721,共7页
BACKGROUND An atrial septal defect is a common condition and accounts for 25%of adult congenital heart diseases.Transcatheter occlusion is a widely used technique for the treatment of secondary aperture-type atrial se... BACKGROUND An atrial septal defect is a common condition and accounts for 25%of adult congenital heart diseases.Transcatheter occlusion is a widely used technique for the treatment of secondary aperture-type atrial septal defects(ASDs).CASE SUMMARY A 30-year-old female patient was diagnosed with ASD by transthoracic echocardiography(TTE)1 year ago.The electrocardiogram showed a heart rate of 88 beats per minute,normal sinus rhythm,and no change in the ST-T wave.After admission,TTE showed an atrial septal defect with a left-to-right shunt,aortic root short-axis section with an ASD diameter of 8 mm,a parasternal four-chamber section with an ASD diameter of 9 mm,and subxiphoid biatrial section with a diameter of 13 mm.Percutaneous occlusion was proposed.The intraoperative TTE scan showed that the atrial septal defect was oval in shape,was located near the root of the aorta,and had a maximum diameter of 13 mm.A 10-F sheath was placed in the right femoral vein,and a 0.035°hard guidewire was used to establish the transport track between the left pulmonary vein and the inferior vena cava.A shape-memory alloy atrial septal occluder with a waist diameter of 20 mm was placed successfully and located correctly.TTE showed that the double disk unfolded well and that the clamping of the atrial septum was smooth.Immediately after the disc was revealed,electrocardiograph monitoring showed that the ST interval of the inferior leads was prolonged,the P waves and QRS waves were separated,a junctional escape rhythm maintained the heart rate,and the blood pressure began to decrease.After removing the occluder,the elevation in the ST segment returned to normal immediately,and the sinus rhythm returned to average approximately 10 min later.After consulting the patient’s family,we finally decided to withdraw from the operation.CONCLUSION Compression of the small coronary artery,which provides an alternative blood supply to the atrioventricular nodule during the operation,leads to the emergence of a complete atrioventricular block. 展开更多
关键词 Completed atrioventricular block Atrial septal defect occluder Atrial septal defect Transthoracic echocardiography Case report
下载PDF
Transcatheter to Close the Patent Duetus Arteriosus and Atrial Septal Defects in Children
20
作者 赵乃琤 王大为 +3 位作者 王凤鸣 龚小平 秦玉明 胡宝珍 《Journal of Nanjing Medical University》 2003年第6期309-312,共4页
Objective: To evaluate the therapeutic effect, safety and complications oftranscathetering Amplatzer device in the closure of patent ductus arteriosus (PDA) and atrial septaldefects (ASD) in children. Methods: Patient... Objective: To evaluate the therapeutic effect, safety and complications oftranscathetering Amplatzer device in the closure of patent ductus arteriosus (PDA) and atrial septaldefects (ASD) in children. Methods: Patients with PDA (n = 25) and ASD ( n = 16), confirmed byechocardiography, were treated by transcatheterization. Amplatzer occluder device was placed by thetranscatheterization with the image support of X-ray and transthoracic echocardiography ( TTE) . TheTTE, ECG and X-ray examination were engaged to evaluate the therapeutic results on the time pointsof 24 h , 1, 3 , 6, 12 months after the operation, and all these cases were engaged to the follow-upexamination. Results: The cardioangiographic diameter was 13.0-28.0 mm ([19.3+-4.9] mm) in ASD and2.0-7.7 mm ([3.9+-1.5] mm) in PDA . The diameter of the Amplatzer occluder selected were 13.0-30.0mm ( [20.6+-5.1] mm) in ASD and 4.0-12.0 mm ([6.6+-1.9] mm) in PDA , respectively. All the Amplatzeroccluders were placed successfully. There were no complications during and after the operation.Very small residual shunt was still found soon after the operation in 10 cases , and there were noresidual or recanalization after three months of the operation. The pulmonary artery pressure andheart size were significantly decreased in follow-up examination . Conclusion: Transcatheteringclosure with Amplatzer device is an effective, simple and safe technique in the treatment of ASD andPDA in children. 展开更多
关键词 patent ductus arteriosus atrial septal defects TRANSCATHETER amplatzerdevice
下载PDF
上一页 1 2 241 下一页 到第
使用帮助 返回顶部