期刊文献+
共找到95篇文章
< 1 2 5 >
每页显示 20 50 100
Synthesis and Solid Phase Extraction Performance Study of NNAL-specific Molecularly Imprinted Polymers Using Dummy Templates 被引量:2
1
作者 张志丹 郑赛晶 +3 位作者 杨俊 王维妙 刘百战 朱晓兰 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2013年第3期361-368,I0004,共9页
Dummy molecularly imprinted polymers (DMIPs) for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) were produced using three structural analogues as dummy template molecules. The chosen analogues were 4-(a... Dummy molecularly imprinted polymers (DMIPs) for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) were produced using three structural analogues as dummy template molecules. The chosen analogues were 4-(acetymethylamino)-1-(3-pyridyl)-butanol, 4- (methylamino)-1-(3-pyridyl)-1-butanol, and 1-(3-pyridyl)-1,4,-butanediol. The molecular recognition characteristics of the produced polymers were evaluated by X-ray photoelec- tron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FT-IR). Interactions between NNAL and methacrylic acid should be cooperative hydrogen bonds while the ni- trogen atom of the pyridine ring and the oxygen atom of the nitroso group in NNAL are two of the hydrogen-bond acceptors. It was further demonstrated that DMIP synthesized by 4-(acetymethylamino)-1-(3-pyridyl)-butanol had the best binding performance by XPS and FT-IR. Then dummy molecularly imprinted solid phase extraction (DMISPE) was developed for the determination of the analyte using the hit polymer as the sorbing material. Under optimal conditions, the recovery of NNAL dissolved in standard solution reached 93%. And the investigated polymer exhibited much higher binding of NNAL when nicotine was acted as the competitive molecule. Also the proposed method was applied to the measurement of NNAL spiked in blank urine samples with recoveries ranging from 87.2% to 101.2%. 展开更多
关键词 Molecularly imprinted polymer Dummy template 4-(Methylnitrosamino)-1-(3-pyridyl)-1-butanol solid phase extraction
下载PDF
Development trend and prospect of solid phase extraction technology 被引量:10
2
作者 Chao Zhang Huifang Xing +2 位作者 Liangrong Yang Pengfei Fei Huizhou Liu 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2022年第2期245-255,共11页
Solid phase extraction is widely used in sample pretreatment,concentration and analysis processes due to high selectivity and suitability for low concentration sample system.In this review,we systematically summarized... Solid phase extraction is widely used in sample pretreatment,concentration and analysis processes due to high selectivity and suitability for low concentration sample system.In this review,we systematically summarized and discussed the development trends of solid phase extraction by bibliometrics method.By analyzing papers output scale,the research and development direction of solid phase extraction technology is prospected.We also give an overview on current strategies of novel solid phase extraction from the separation medium and separation technology.The paper aims to describe the global research profile and the development trends of solid phase extraction,to help researchers to accurately grasp the research trend and to provide support for scientific research institutions to formulate scientific policies and strategic plans.Furthermore,the prospect of the development and application of solid phase extraction is also discussed. 展开更多
关键词 solid phase extraction Papers output scale Quality of research Novel technology
下载PDF
Determination of resveratrol in red wine by solid phase extraction-flow injection chemiluminescence method 被引量:7
3
作者 Juan Juan Ren Hai Yan Liu +2 位作者 Yu Hong Hao Pin Gang He Yu Zhi Fang 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第8期985-988,共4页
A sensitive flow injection chemiluminescence method has been developed for the detection of resveratrol in red wine based on the fact that resveratrol can greatly enhance chemiluminescence reaction between KMnO4 and H... A sensitive flow injection chemiluminescence method has been developed for the detection of resveratrol in red wine based on the fact that resveratrol can greatly enhance chemiluminescence reaction between KMnO4 and HCHO in sulfuric acid medium. Analytes were pre-concentrated on solid sorbents (C18 solid-phase extraction cartridges). Under the optimum conditions, the proposed method allows the measurement of resveratrol over the range of 1.32 × 10^-8 to 1.32 × 10^-5 mol/L with a detection limit of 3.30 ×10^-9 mol/L, and the relative standard deviation for 1.32 ×10^-5 mol/L resveratrol (n = 11) is 3.8%. This method has been successfully applied for the determination of the resveratrol in red wine. Furthermore, the possible reaction mechanism was also discussed. 展开更多
关键词 RESVERATROL solid phase extraction How-injection chemiluminescence Potassium permanganate FORMALDEHYDE
下载PDF
Solid Phase Extraction Chemiluminescence Determination of Methamidaphos on Vegetables 被引量:5
4
作者 LI Xiao-zhou GUAN Ting-ting +2 位作者 ZHOU Chi YIN Ji-qiu ZHANG Yi-hua 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2006年第1期21-24,共4页
The determination of the methamidaphos pesticide residue on vegetables with a simple solid phase extract(SPE) flow injection(FI) -chemiluminescence(CL) method is described. The method is based on the enhancing e... The determination of the methamidaphos pesticide residue on vegetables with a simple solid phase extract(SPE) flow injection(FI) -chemiluminescence(CL) method is described. The method is based on the enhancing effect of methamidaphos on the CL reaction of luminol with hydrogen peroxide in an alkaline solution. Under the optimal conditions, the CL intensity is linear to the methamidaphos mass concentration in a range of 0. 2-13μg/mL ( r= 0. 9992). The detection limit(3σ) is 0. 047μg/mL. The relative standard deviations for the analysis of three samples are 1.8%, 2.5% and 3.7% ( n = 5 ), respectively. The recovery is in a range of 90%-109% by the method. In this work, this method was successfully applied to the determination of the methamidaphos residue on some vegetable samples. 展开更多
关键词 CHEMILUMINESCENCE Flow injection solid phase extraction Methamidaphos
下载PDF
Simultaneous Determination of Bisphenols and Alkylphenols in Water by Solid Phase Extraction and Ultra Performance Liquid Chromatography-tandem Mass Spectrometry 被引量:4
5
作者 SHAN Xiao Mei SHEN Deng Hui +2 位作者 WANG Bing Shuang LU Bei Bei HUANG Fa Yuan 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第6期471-474,共4页
To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry ... To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%. 展开更多
关键词 UPLC BPA Simultaneous Determination of Bisphenols and Alkylphenols in Water by solid phase extraction and Ultra Performance Liquid Chromatography-tandem Mass Spectrometry MASS
下载PDF
Rapid analysis of fifteen sulfonamide residues in pork and fish samples by automated on-line solid phase extraction coupled to liquid chromatography–tandem mass spectrometry 被引量:6
6
作者 Junmei Ma Sufang Fan +3 位作者 Lei Sun Liangna He Yan Zhang Qiang Li 《Food Science and Human Wellness》 SCIE 2020年第4期363-369,共7页
The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples... The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish. 展开更多
关键词 Liquid chromatography–tandem mass SPECTROMETRY On-line solid phase extraction SULFONAMIDES Internal standard quantification
下载PDF
Determination of Sulfadimidine in Royal Jelly by C_(18)-functionalized Magnetic Silica Nanoparticles Solid Phase Extraction-High Performance Liquid Chromatography-Tandem Mass Spectrometry
7
作者 李金峰 李颖 +3 位作者 蒋原 薛峰 戴劲 朱海 《Agricultural Science & Technology》 CAS 2012年第11期2278-2280,共3页
[Objective] This study aimed to develop a method of C_18-functionalized magnetic silica nanoparticles solid phase extraction-high performance liquid chro- matography-tandem mass spectrometry for the determination of s... [Objective] This study aimed to develop a method of C_18-functionalized magnetic silica nanoparticles solid phase extraction-high performance liquid chro- matography-tandem mass spectrometry for the determination of sulfadimidine in royal jelly. [Method] The royal jelly samples were pretreated by MCX SPE column and C_18-functionalized magnetic silica nanoparticles, and the purified samples were de- tected by HPLC-MS/MS. [Result] The detection method showed a good linear rela- tionship in the range of 5-80 ugkg (r=0.993 1). The recovery ranges were between 93%- 104% with the relative standard deviations (RSD) below 11.3%. [Conclusion] Combined with automation equipment, the method is simple, fast, time-saving, and easy to real- ize the automation of sulfadimidine in the royal jelly samples before determination. 展开更多
关键词 solid phase extraction Magnetic silica nanoparticles Sulfadimidine Highperformance liquid chromatography-tandem mass spectrometry
下载PDF
Preconcentration of copper with multi-walled carbon nanotubes pretreated by potassium permanganate cartridge for solid phase extraction prior to flame atomic absorption spectrometry 被引量:2
8
作者 Jun Ping Xiao Qing Xiang Zhou Hua Hua Bai 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第6期714-717,共4页
A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water s... A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water samples. Important parameters, such as the sample pH, the concentration and volume of eluent, sample flow rate and volume, and interference of coexisting ions, were investigated. The obtained results indicated that proposed method possessed an excellent analytical performance. The linear range, the detection limit, and precison (RSD) were 1–100 ng/mL (R(2) = 0.9993), 0.32 ng/mL and 2.88%, respectively. The results showed that copper could be adsorbed quantitatively on the pretreated MWCNTs with potassium permanganate, and proposed method was very useful in the monitoring of copper in the environment. 展开更多
关键词 Multi-walled carbon nanotubes solid phase extraction (SPE) Flame atomic absorption spectrometry
下载PDF
Comparison of Different Cartridges of Solid Phase Extraction for Determination of Polyphenols in Tobacco by UPLC/MS/MS and Multivariate Analysis 被引量:1
9
作者 ZHANG Xia LIU Wei +6 位作者 XU Yong YANG Liu KONG Wei-song RUI Xiao-dong YANG Shuai CHEN Yong-kuan MIAO Ming-ming 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第4期550-556,共7页
The comparison of solid phase extraction(SPE) for the preconcentration and isolation of polyphenols in tobacco samples was carried out by ultra-high performance liquid chromatography/tandem mass spectrometry (UPLC/... The comparison of solid phase extraction(SPE) for the preconcentration and isolation of polyphenols in tobacco samples was carried out by ultra-high performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) and multivariate analysis.Several adsorbing materials of SPE(C18,NH2,SAX and OASIS) were investigated.It was found that the C18 and OASIS cartridges can not only speed up the purification process,but also simplify the SPE operation.A UPLC/MS/MS was used for the determination of polyphenols in tobacco samples after purification.All analytes were separated and determined in 2min.The limit of detection was 0.05 ng/mL.Cluster analysis(CA) and principal component analysis(PCA) were used for the analysis of 4 varieties(flue-cured tobacco,oriental tobacco,sun-cured tobacco and burley) in order to interpret the effect of planting and machining process on the concentration of polyphenols.The different types of tobacco samples could be easily clustered by CA.PCA on the chemical composition of tobacco resulted in two principal components(PCs) that take 84.2% of the total variance.The PCA and CA indicate that the polyphenols can be used for distinguishing tobacco types. 展开更多
关键词 solid phase extraction POLYPHENOL Ultra-high performance liquid chromatography/tandem mass spectro-metry(UPLC/MS/MS) TOBACCO Cluster analysis Principal component analysis
下载PDF
Solid phase extraction of methomyl and thiodicarb from environmental water with an activated carbon cartridge and their determination by HPLC
10
作者 Chen, Yan-Jun Lu, Ying-Hua +1 位作者 Liu, Jun Chen, Ya-Min 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2000年第1期100-104,共5页
A solid phase extraction procedure of methomyl and thiodicarb from environmental water was presented. This method utilizes a 40—60 mesh activated carbon cartridge and high performance liquid chromatography (HPLC). Th... A solid phase extraction procedure of methomyl and thiodicarb from environmental water was presented. This method utilizes a 40—60 mesh activated carbon cartridge and high performance liquid chromatography (HPLC). The 40—60 mesh activated carbon works faster and yield higher adsorption efficiency. Detection limits of methomyl and thiodicarb in environmental water are 0 1 μg/L and 0 2 μg/L, respectively. Average recoveries of fortified methomyl and thiodicarb in water are in the range of 90 7%—98 8% and 88 9%—103 6%, respectively. The relative standard deviations are lower than 7%. This method is simple, rapid, accurate and precise. 展开更多
关键词 HPLC solid phase extraction activated carbon METHOMYL thiodicarb CLC number: X592 Document code: A
下载PDF
Determination of Fe, Cu, and Zn in Water Samples by Microcolumn Packed with Multiwalled Carbon Nanotubes as a Solid Phase Extraction Adsorbent Using ICP-MS
11
作者 A. Ahmad H.M. Al-Swaidan 《Journal of Environmental Science and Engineering》 2011年第4期410-419,共10页
The heavy metals determination in tap water samples using microcolumn packed with multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent before to their determination by inductively coupled plasm... The heavy metals determination in tap water samples using microcolumn packed with multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent before to their determination by inductively coupled plasma mass spectrometry (ICP-MS) has been studied. Standard addition method was applied for the calibration using aqueous solutions. The metals ions absorption were achieved by multiwalled carbon nanotubes (MWNTs) at pH 8.0, and then these retained metals on MWNTs column were eluted by 1.0 mol.L^-1 HNO3. The analytical parameters for the determination ofFe, Cu, and Zn in tap water samples which have been investigated previously were applied. Fifteen tap water samples were collected from different locations of Riyadh metropolitan area and then determined the concentration ofFe, Cu, and Zn by ICP-MS after preconcentration with MWNTs. The concentration range for Fe, Cu, and Zn measured (μg/L) in water samples are 23.37-137.91, 2.12-121.36, and 14.43-202.47 respectively. The level of Fe exceeded the limits set by WHO and SASO for drinking water. 展开更多
关键词 Multiwalled carbon nanotubes (MWNTs) solid phase extraction (SPE) heavy metals nitric acid (HNO3) PTFE micro-column inductively coupled plasma mass spectrometry (ICP-MS).
下载PDF
Determination of volatile organic compounds in river water by solid phase extraction and gas chromatography 被引量:4
12
作者 M.A.Mottaleb M.Z.Abedin M.S.Islam 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2004年第3期497-501,共5页
A simple, rapid, and reproducible method is described employing solid phase extraction(SPE) using dichloromethane followed by gas chromatography(GC) with flame ionization detection(FID) for determination of volatile ... A simple, rapid, and reproducible method is described employing solid phase extraction(SPE) using dichloromethane followed by gas chromatography(GC) with flame ionization detection(FID) for determination of volatile organic compound(VOC) from the Buriganga River water of Bangladesh. The method was applied to detect the benzene, toluene, ethylbenzene, xylene and cumene(BTEXC) in the sample collected from the surface or 15 cm depth of water. Two hundred ml of n hexane pretreated and filtered water samples were applied directly to a C 18 SPE column. BTEXC were extracted with dichloromethane and average concentrations were obtained as 0 104 to 0 372 μg/ml. The highest concentration of benzene was found as 0 372 μg/ml with a relative standard deviation(RSD) of 6 2%, and cumene was not detected. Factors influencing SPE e.g., adsorbent types, sample load volume, eluting solvent, headspace and temperatures, were investigated. A cartridge containing a C 18 adsorbent and using dichloromethane gave better performance for extraction of BTEXC from water. Average recoveries exceeding 90% could be achieved for cumene at 4℃ with a 2 7% RSD. 展开更多
关键词 solid phase extraction river water environmental analysis VOC recoveries
下载PDF
Sensitive measurement of silver ions in environmental water samples integrating magnetic ion-imprinted solid phase extraction and carbon dot fluorescent sensor
13
作者 Shuangying Li Qingxiang Zhou +2 位作者 Zhi Li Menghua Liu Yanhui Li 《Chinese Chemical Letters》 SCIE CAS CSCD 2024年第5期272-276,共5页
Increasing use of silver in various fields has caused Ag^(+)pollution in water environment,taking great threats to people’s health.As a consequence,establishing rapid and reliable methods for sensitive determination ... Increasing use of silver in various fields has caused Ag^(+)pollution in water environment,taking great threats to people’s health.As a consequence,establishing rapid and reliable methods for sensitive determination of Ag^(+)is of great significance.Fluorescent(FL)sensors based on carbon dots(CDs),an excellent carbonaceous nanomaterial with strong and stable fluorescence,have absorbed extensive attentions in analysis of pollutants due to its advantages of carbon sources being readily available,low cost,easy operation and fast response.Moreover,ion-imprinting is a better way to increase the selectivity of the proposed method.Present work described an effective method for the sensitive measurement of silver ion in water samples in combination with magnetic ion-imprinted solid phase extraction and CDs based fluorescent sensor,which took full advantages of easy separation and high enrichment of magnetic solid phase extraction,high selectivity of ion-imprinting technology,and sensitivity and rapid response of fluorescent sensor from CDs.Sulfur-doped CDs derived from dithizone and magnetic ion-imprinted nanomaterial were prepared,and characterized with Fourier transform infrared spectroscopy and transmission electron microscope,etc.Magnetic Ag^(+)imprinted nanomaterial based solid phase extraction was employed for separating and enriching Ag^(+)from water samples.The significant parameters were optimized in detail.Under the optimal conditions,the proposed method provided good linearity in the range of 0.01-0.4μmol/L and low detection limit of 3 nmol/L.The reliability of the proposed method was validated with real water samples,and the results demonstrated that the proposed method was simple,robust,selective and sensitive detection tool for Ag^(+)in real water samples. 展开更多
关键词 Carbon dots Ag^(+) Magnetic ion-imprinting Magnetic solid phase extraction Fluorescent sensor
原文传递
Development and assessment of an onsite large volume solid phase extraction (LV-SPE) device for the determination of pharmaceuticals and personal care products (PPCPs) in water
14
作者 Xue Cheng Ning Fang +5 位作者 Yuxi Ge Wenchao Li Yamei Hui Zilong Tang Yu Wan Yuancheng Li 《Emerging Contaminants》 CSCD 2024年第1期24-31,共8页
It is essential to determine the occurrence of emerging organic contaminants(EOCs),such as pharmaceuticals and personal care products(PPCPs),in the ambient environment to address growing public concerns.However,such a... It is essential to determine the occurrence of emerging organic contaminants(EOCs),such as pharmaceuticals and personal care products(PPCPs),in the ambient environment to address growing public concerns.However,such analysis is quite challenging due to the low trace level of such contaminants in water,which therefore requires several litres of water samples.In this study,a large volume solid phase extraction(LV-SPE)device was developed and evaluated for its performance in monitoring PPCPs as an example.Relatively good recoveries and reproducibility were obtained under specific operating conditions:a water sample volume of no more than 20 L,a flow rate not exceeding 120 mL/min,and a methanol elution volume of at least 30 mL.In addition,the results from the onsite enrichment approach using LV-SPE were compared with those from the conventional approach using a standard SPE device in the laboratory for real groundwater samples.Among the eight selected PPCPs(nalidixic acid,carbamazepine,bezafibrate,clofibric acid,sulfadiazine,sulfamethoxypyridazine,sulfamethazine and sulfamonomethoxine),LV-SPE approach detected more target compounds.While the detected concentrations were generally comparable,slightly higher concentrations were observed for carbamazepine,clofibric acid,sulfadiazine and sulfamethazine using the LV-SPE method.The developed LV-SPE device provides an alternative approach for trace analysis of PPCPs and may also be applicable for other emerging organic contaminants. 展开更多
关键词 Large-volume solid phase extraction Onsite enrichment PPCPS Emerging organic pollutants
原文传递
Determination of organochlorine pesticides from juice samples using magnetic biochar-based dispersive micro-solid phase extraction in combination with dispersive liquid-liquid microextraction
15
作者 Kero Assefa Ago Shimeles Addisu Kitte Abera Gure 《Emerging Contaminants》 CSCD 2024年第1期126-138,共13页
Analysis of pesticide residue levels in juice beverages is important to ensure safe consumption and avoid global trade concerns associated to pesticide contaminations.A simple,inexpensive and effective method was deve... Analysis of pesticide residue levels in juice beverages is important to ensure safe consumption and avoid global trade concerns associated to pesticide contaminations.A simple,inexpensive and effective method was developed for the determination of organochlorine pesticides(OCPs)in bottled juice drinks using GC-MS.Sample pretreatment was performed using dispersive solid-phase microextraction(D-μ-SPE)for matrix desorption and dispersive liquid-liquid microextraction(DLLME)for analyte enrichment.In this study,an affordable and effective sorbent for the adsorption of OCPs from juice samples was synthesized from avocado seeds mixed with magnetic precursors for D-μSPE.The ground avocado seeds combined with a magnetic precursor nanocomposite were characterized using various instruments including scanning electron microscopy(SEM),X-ray diffraction(XRD),Fourier transform infrared spectroscopy(FTIR),and Brunauer-Emmett-Teller(BET)analysis.The solution obtained from D-μ-SPE desorption was used as a dispersant for the subsequent DLLME,which made the combination of D-μ-SPE with DLLME much easier.The effectiveness of the method was enhanced by optimizing the influential parameters in both D-μ-SPE and DLLME.Then after,the optimal values were determined for the real sample analysis.Accordingly,there was good linear dynamic range with a coefficient of determination(r2)≥0.9989.The limit of detection and quantification were 0.02–0.69 and 0.06–2.10 ng/L respectively.The method showed high enrichment factors ranging from 96 to 313 with recoveries of 87–100%.Intraday and interday precisions were≤4%.Compared with other reported methods,this method is a one-step,simple,cheap,fast,and environmentally friendly alternative and straightforward method for adsorbing organochlorine pesticides from sample solutions.These results demonstrates the high potential of the proposed method for the extraction and cleanup of contaminants in selected juices and other related samples. 展开更多
关键词 Dispersive micro solid phase extraction Dispersive liquid-liquid microextraction Juice samples Magnetic biochar Organochlorine pesticides Gas chromatography-mass spectrometry
原文传递
Development of new solid phase extraction techniques in the last ten years 被引量:4
16
作者 范惠霞 邓志鹏 +1 位作者 仲浩 姚庆强 《Journal of Chinese Pharmaceutical Sciences》 CAS CSCD 2013年第4期293-302,共10页
Solid phase extraction (SPE) is a widely used sample pretreatment method for separation, purification and enrichment, which has been established due to its significant advantages of time-saving, low consumption of s... Solid phase extraction (SPE) is a widely used sample pretreatment method for separation, purification and enrichment, which has been established due to its significant advantages of time-saving, low consumption of solvent, high enrichment factor, high accuracy, etc. In recent years, a variety of new SPE methods such as molecularly imprinted solid phase extraction (MISPE), magnetic solid phase extraction (MSPE), solid phase micro-extraction (SPME), etc., which are superior to the conventional SPE, have been developed and been widely applied to food, drugs, and environmental monitoring. In this paper, the basic principles and methods of SPE and its new applications in different areas are reviewed. 展开更多
关键词 solid phase extraction Molecularly imprinted solid phase extraction Magnetic solid phase extraction solid phase micro-extraction
原文传递
Determination of Eleutheroside B and E in Acanthopanax Preparations by High-P erformance Liquid Chromatography with Solid-Phase Extraction 被引量:6
17
作者 胡芳弟 封士兰 +2 位作者 赵健雄 陈立仁 徐静汶 《Journal of Chinese Pharmaceutical Sciences》 CAS 2005年第1期51-55,共5页
Aim An HPLC method for analyzing eleutheroside B (ELU B) and eleutheroside E(ELU E) , two of the main active substances of Acanthopanax preparations were studied. Methods Thesamples were analyzed on a kromasil ODS col... Aim An HPLC method for analyzing eleutheroside B (ELU B) and eleutheroside E(ELU E) , two of the main active substances of Acanthopanax preparations were studied. Methods Thesamples were analyzed on a kromasil ODS column with water-acetonitrile as a gradient mobile phase.The flow rate was 0.8 mL·min^(-1) and detecting wavelengths were 206 nm for ELU B, 220 nm for ELUE, solid phase extraction (SPE) and internal standard-salicin were selected. Results The recoveriesof Acanthopanax tablets and injection were 90.4% - 96.8% and 96.4% - 99.8% for ELU B, 87.7% -93.3%and 95.7% - 98.5% for ELU E, respectively. The linear ranges were 4.45 - 22.25 μg· mL^(-1) (r =0.999 8) and 5.11 - 25.55 μg·mL^(-1) ( r = 0.999 7) respectively. Conclusion This method can savethe time for cleaning the chromatographic system and improve sensitivity for Acanthopanaxpreparations , thus providing a way to evaluate the quality of Acanthopanax preparations. 展开更多
关键词 eleutherosides acanthopanax preparations HPLC solid phase extraction
下载PDF
Detection of geosmin and 2-methylisoborneol by liquid-liquid extraction-gas chromatograph mass spectrum (LLE-GCMS) and solid phase extraction-gas chromatograph mass spectrum (SPE-GCMS) 被引量:7
18
作者 MA Xiaoyan GAO Naiyun +3 位作者 CHEN Beibei LI Qingsong ZHANG Qiaoli GU Guofen 《Frontiers of Environmental Science & Engineering》 SCIE EI CSCD 2007年第3期286-291,共6页
Two sample preparation methods were introduced and compared in this paper to establish a simple,quick and exact analysis of geosmin and 2-methylisoborneol.LC-18 column was employed in solid phase extraction(SPE),1.0 m... Two sample preparation methods were introduced and compared in this paper to establish a simple,quick and exact analysis of geosmin and 2-methylisoborneol.LC-18 column was employed in solid phase extraction(SPE),1.0 mL of hexane was adopted in liquid-liquid extraction(LLE),and the extracts were analyzed by gas chromatograph mass spectrum(GCMS)in selected ion mode.Mean recoveries of SPE were low for 2-methylisoborneol(2-MIB)and geosmin(GSM)with values below 50%.For LLE,the recoveries were satisfyingly above 50%for 2-MIB and 80%for GSM.Detection limits of the LLE method were as low as 1.0 ng/L for GSM and 5.0 ng/L for 2-MIB.A year-long investigation on odor chemicals of drinking water in Shanghai demonstrated that in the summer,there was a serious odor problem induced by a high concentration of 2-MIB.The highest concentration of 152.82 ng/L appeared in July in raw water,while GSM flocculation was minimal with concentrations below odor threshold. 展开更多
关键词 geosmin(GSM) 2-methylisoborneol(2-MIB) liquid-liquid extraction(LLE) solid phase extraction(SPE) drinking water water source
原文传递
Determination of 4-tert-octylphenol in surface water samples of Jinan in China by solid phase extraction coupled with GC-MS 被引量:4
19
作者 Xueyu Yang Mingren Liu +2 位作者 Zhongpeng Wang Qian Li Zhaoliang Zhang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2013年第8期1712-1717,共6页
Octylphenols, considered as xenoestrogens, mainly exist as 4-tert-octylphenol (OP) in aquatic environments. The high stability and accumulation of OP in aquatic systems have caused endocrine disruption. The OP in su... Octylphenols, considered as xenoestrogens, mainly exist as 4-tert-octylphenol (OP) in aquatic environments. The high stability and accumulation of OP in aquatic systems have caused endocrine disruption. The OP in surface water in Jinan, China was analyzed by gas chromatography-mass spectrometry (GC-MS) coupled with solid phase extraction (SPE). Water samples were extracted by SPE on a cartridge system containing C-18 as sorbent. To increase sensitivity and selectivity, OP was derivatized to 4-tert-octyl-phenoxy silane. With the use of phenanthrene-d10 as internal standard, the detection limit based on signal-to-noise ratio (S/N = 3) was 0.06 ng/mL. The average recovery was from 84.67% to 109.7%. The precision of the method given as the relative standard deviations (RSD) was within the range 6.24%-12.96%. In the target water samples, the concentrations of OP were as follows: 15.88-71.24 ng/L for Jinxiuchuan Reservoir, 3.850-26.68 ng/L for the city moat, 6.930-41.56 ng/L for Daming Lake, 66.03-474.2 ng/L for Xiaoqing River, 14.66-17.72 ng/L for the Yellow River, and 10.60-26.43 ng/L for Queshan Reservoir. The Xiaoqing River was seriously polluted due to the discharge of wastewater from Jinan. Jinxiuchuan Reservoir had a higher concentration of OP compared with the Yellow River and Queshan Reservoir, which is ascribed to the surrounding human activities. These data are reported for the first time, providing strong support for the control of OP pollution in Jinan. 展开更多
关键词 GC-MS OCTYLPHENOL Jinan solid phase extraction DERIVATIZATION internal standard
原文传递
A novel surface molecularly imprinted polymer as the solid-phase extraction adsorbent for the selective determination of ampicillin sodium in milk and blood samples 被引量:6
20
作者 Ningli Wu Zhimin Luo +7 位作者 Yanhui Ge Pengqi Guo Kangli Du Weili Tang Wei Du Aiguo Zeng Chun Chang Qiang Fu 《Journal of Pharmaceutical Analysis》 SCIE CAS 2016年第3期157-164,共8页
Surface molecularly imprinted polymers (SMIPs) for selective adsorption of ampicillin sodium were synthesized using surface molecular imprinting technique with silica gel as a support. The physical and morphological... Surface molecularly imprinted polymers (SMIPs) for selective adsorption of ampicillin sodium were synthesized using surface molecular imprinting technique with silica gel as a support. The physical and morphological characteristics of the polymers were investigated by scanning electron microscope (SEM), Fourier transform infrared spectroscopy (FT-IR), thermogravimetric analysis (TGA), elemental analysis and nitrogen adsorption-desorption test. The obtained results showed that the SMIPs displayed great adsorption capacity (13.5 lag/mg), high recognition ability (the imprinted factor is 3.2) and good binding kinetics for ampicillin sodium. Finally, as solid phase extraction adsorbents, the SMIPs coupled with HPLC method were validated and applied for the enrichment, purification and determination of anapicillin sodium in real milk and blood samples. The averages of spiked accuracy ranged from 92.1% to 107.6%. The relative standard deviations of intra- and inter-day precisions were less than 4.6%. This study provides a new and promising method for enriching, extracting and determining ampicillin sodium in complex biological samples. 展开更多
关键词 Ampicillin sodium Surface molecularly imprinted polymers solid phase extraction High performance liquid chromatography
下载PDF
上一页 1 2 5 下一页 到第
使用帮助 返回顶部