期刊文献+
共找到16篇文章
< 1 >
每页显示 20 50 100
Developing Operational Model for Heat Pumps as Space Heating and Domestic Hot Water Provider
1
作者 Rilwan Olaolu Oliyide Jose B. Hernandez 《Open Journal of Applied Sciences》 2024年第10期2880-2900,共21页
In the United Kingdom, means of meeting domestic heating is being electrified to decarbonise in effort to reduce the greenhouse gases emissions from the burning of natural gas. Therefore, the uptake of heat pumps is o... In the United Kingdom, means of meeting domestic heating is being electrified to decarbonise in effort to reduce the greenhouse gases emissions from the burning of natural gas. Therefore, the uptake of heat pumps is on the increase. The operation and working principle of heat pumps must be well understood in the investigations of their impacts on the grid and the grid assets, especially distribution transformers which could be overloaded due to higher peak load demand. This work develops an operational model of heat pumps as combined space heating and domestic hot water provider implemented in MATLAB. The developed operational model of heat pumps is adaptable and repeatable for different input parameters. The developed model is used to generate daily average demand profiles of heat pumps for a typical winter weekday and a typical summer weekday. The generated demand profiles of heat pumps by the developed model compared well with the demand profiles of heat pumps generated from actual field projects which are usually expensive and time-tasking. 展开更多
关键词 Heat Pumps Greenhouse Gases space heating Domestic Hot Water TRANSFORMER MATLAB
下载PDF
Performance investigation of solar thermal collector with auxiliary heater for space heating 被引量:3
2
作者 Hassan BIGLARIAN Mohammad Mazidi SHARFABADI +1 位作者 Mansour ALIZADEH Hossein GHARAEI 《Journal of Central South University》 SCIE EI CAS CSCD 2021年第11期3466-3476,共11页
In this paper,the performance of a solar thermal system with a focus on space heating was investigated.A 70 m^(2) detached house was considered in the weather conditions of the city of Tehran,Iran.A thermosyphon solar... In this paper,the performance of a solar thermal system with a focus on space heating was investigated.A 70 m^(2) detached house was considered in the weather conditions of the city of Tehran,Iran.A thermosyphon solar water heater with a flat plate collector combined with an auxiliary electrical heater supplies the heating demand of the house.The proposed system was modeled and analyzed using TRNSYS software.In this regard,the TRNBuild module was employed for the building load calculation.The model has been simulated for one year of operation.The effects of the solar collector’s surface area and storage volume were assessed.The results show that for a solar collector with a 15 m^(2) surface area,the solar fraction is 0.29 in January,during which the solar radiation is the lowest.Using solar collectors of10 m^(2) and 5 m^(2) surface areas,the solar fraction falls to 0.23 and 0.14,respectively in January.Besides,two cases of 150 L and 300 L storage tanks are taken into account.Eventually,it is found that using a 15 m^(2) solar collector and a 150 L storage tank can appropriately provide the building’ s heating demand taking the thermal performance and economic aspects into consideration. 展开更多
关键词 space heating solar water heater THERMOSIPHON solar collector TRNSYS software
下载PDF
Operation Performance of Air Source Heat Pump System for Space Heating in Tianjin 被引量:2
3
作者 赵军 陈雁 +1 位作者 曲航 李新国 《Transactions of Tianjin University》 EI CAS 2007年第2期137-141,共5页
An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the ... An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃. 展开更多
关键词 air source heat pump system(ASHPS) space heating defrosting parameter COP
下载PDF
Space heating and hot water demand analysis of dwellings connected to district heating scheme in UK
4
作者 R.Burzynski M.Crane +1 位作者 R.Yao V.M.Becerra 《Journal of Central South University》 SCIE EI CAS 2012年第6期1629-1638,共10页
To achieve CO2 emissions reductions, the UK Building Regulations require developers of new residential buildings to calculate expected CO2 emissions arising from their energy consumption using a methodology such as St... To achieve CO2 emissions reductions, the UK Building Regulations require developers of new residential buildings to calculate expected CO2 emissions arising from their energy consumption using a methodology such as Standard Assessment Procedure (SAP 2005) or, more recently SAP 2009. SAP encompasses all domestic heat consumption and a limited proportion of the electricity consumption. However, these calculations are rarely verified with real energy consumption and related CO2 emissions. This work presents the results of an analysis based on weekly heat demand data for more than 200 individual fiats. The data were collected from a recently built residential development connected to a district heating network. A method for separating out the domestic hot water (DHW) use and space heating (SH) demand has been developed and these values are compared to the demand calculated using SAP 2005 and SAP 2009 methodologies. The analysis also shows the variation in DHW and SH consumption with size of flats and with tenure (privately owned or social housing). Evaluation of the space heating consumption also includes an estimate of the heating degree day (HDD) base temperature for each block of fiats and compares this to the average base temperature calculated using the SAP 2005 methodology. 展开更多
关键词 domestic hot water space heating energy consumption heat demand
下载PDF
Field survey of indoor thermal comfort in rural housing of northern China in heating season 被引量:3
5
作者 黄莉 朱颖心 +1 位作者 欧阳沁 曹彬 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期169-172,共4页
This paper introduces a field measurement of an indoor thermal environment in rural housing in suburban Beijing from December 2008 to March 2009.The indoor environment parameters such as air temperature,mean radiant t... This paper introduces a field measurement of an indoor thermal environment in rural housing in suburban Beijing from December 2008 to March 2009.The indoor environment parameters such as air temperature,mean radiant temperature(MRT),airflow velocity and relative humidity are measured.A questionnaire survey of the occupants' thermal sensations in these surveyed houses is conducted and their daily activities and clothing conditions are recorded.The results show that the thermal neutral temperature of rural housing is 18.4 ℃,and the lower limit of acceptable temperature range can be extended to 10.9 ℃.The comfortable indoor temperature is affected by the occupants' clothing and lifestyle.Therefore,the indoor temperature standards of space heating for suburban housing cannot be simply duplicated from that for urban housing.Compared with occupants in suburban Beijing,it is found that the occupants in rural Hunan province feel colder at the same operative temperature due to the high relative humidity in Hunan province. 展开更多
关键词 rural housing thermal comfort field survey space heating
下载PDF
Research on Energy-Saving Performance of Intermittent Heating for Rooms in Hot Summer&ColdWinter Zone
6
作者 Guoqing Yu Nan Fang +1 位作者 Dingke Hu Wei Zhao 《Energy Engineering》 EI 2023年第7期1563-1582,共20页
In the hot summer&cold winter zone in China,intermittent heating space for rooms is widely used.However,in comparison with continuous space heating,the energy-saving performance of intermittent space heating has n... In the hot summer&cold winter zone in China,intermittent heating space for rooms is widely used.However,in comparison with continuous space heating,the energy-saving performance of intermittent space heating has not been sufficiently investigated.This paper studied the factors influencing the energy performance of intermittent heating for the representativeoffice inhot summer&coldwinter zone.Basedon theheatbalancemethod,adynamic thermalmodel of the intermittent heating roomwas built and tested by experiments.And then,it analyzed the total space heating load,the amount of energy saving and energy saving ratio of the intermittent heating under different preheating hours,occupation hours,required roomtemperatures,air change rates,overall heat transfer coefficients(U-value)of windows and wall materials.If the adjacent rooms were not heated,for a typical room occupied about 10 h a day,the energy-saving ratio of intermittent heating was about 30%compared with continuous heating.But the preheating power was higher than two times of continuous heating.The results also indicated that the occupation hours had a significant effect on energy saving amount and ratio,it should be noted that the energy saving ratio by intermittent heating was much lower than the unoccupied period ratio.Relative to other factors,the heating temperatures,room air change rates and U-value of windows,and room envelope materials had little effect on energy efficiency.If the adjacent rooms were heated in the same manner as the roomin question,the energy-saving ratio of the total load of intermittent heating was heavily reduced to 8.46%. 展开更多
关键词 Intermittent heating space heat load continuous heating hot summer&cold winter zone energy saving ratio
下载PDF
Optimization of Serial Combined System of Ground-Coupled Heat Pump and Solar Collector 被引量:1
7
作者 赵军 陈雁 +1 位作者 卢素珍 崔俊奎 《Transactions of Tianjin University》 EI CAS 2009年第1期37-42,共6页
A mathematical optimization model was set up for a ground-solar combined system based on in-situ experimental results, in which the solar collector was combined serially with a ground-coupled heat pump (GCHP). The uni... A mathematical optimization model was set up for a ground-solar combined system based on in-situ experimental results, in which the solar collector was combined serially with a ground-coupled heat pump (GCHP). The universal optimal equations were solved by the constrained variable metric method considering both the per-formance and economics. Then the model was applied to a specific case concerning an actual solar assisted GCHP system for space heating. The results indicated a system coefficient of performance (COP) of 3.9 for the optimal method under the serial heating mode, and 3.2 for the conventional one. In addition, the optimum solution also showed advantages in energy and cost saving, leading to a 16.7% improvement in the heat pump performance at 17.2% less energy consumption and 11.8% lower annual cost, respectively. 展开更多
关键词 ground-solar combined system OPTIMIZATION space heating ground-coupled heat pump
下载PDF
Application of Geothermal Energy to New Countryside Construction——A Case Study of Xiong County, Hebei Province
8
作者 WANG Shu-fang 《Meteorological and Environmental Research》 CAS 2012年第11期61-64,共4页
Hujiatai Village, Xiong County, Hebei Province was nominated as the experimental unit of new countryside construction by Hebei Province in 2008. In order to make Hujiatai Village become a new countryside model with fr... Hujiatai Village, Xiong County, Hebei Province was nominated as the experimental unit of new countryside construction by Hebei Province in 2008. In order to make Hujiatai Village become a new countryside model with friendly ecological and environmental conditions, local energy resources should be considered. In this study, a mode of 'geothermal energy extraction-heat exchange-space heating-reinjection' was adopted to supply heat to resident houses in Hujiatai Village cooperating with a geothermal development entity based on the abundant geothermal resources, thereby constructing a clean, economic and autarkic new countryside energy system, which avoids utilization of fossil-energy, reduces emission of greenhouse gases and generation of solid coal cinder, protecting air and land environment, improving life quality of the people and building a typical model for Hebei Province and even for the whole country. 展开更多
关键词 Geothermal energy Geothermal space heating Saving energy and reducing greenhouse gases emissions New countryside construction China
下载PDF
Comparison of space cooling/heating load under non-uniform indoor environment with convective heat gain/loss from envelope 被引量:2
9
作者 Shuai Yan Xianting Li 《Building Simulation》 SCIE EI CSCD 2021年第3期565-578,共14页
The indoor parameters are generally non-uniform distributed.Consequently,it is important to study the space cooling/heating load oriented to local requirements.Though the influence of indoor set point,heat sources,and... The indoor parameters are generally non-uniform distributed.Consequently,it is important to study the space cooling/heating load oriented to local requirements.Though the influence of indoor set point,heat sources,and ambient temperature of convective thermal boundary on cooling/heating load has been investigated in the uniform environment in previous research,the influence of these factors,particularly the convective heat gain/loss through a building envelope,on cooling/heating load of non-uniform environment has not yet been investigated.Therefore,based on the explicit expression of indoor temperature under the convective boundary condition,the expression of space cooling/heating load with convective heat transfer from the building envelope is derived and compared through case studies.The results can be summarized as follows.(1)The convective heat transferred through the building envelope is significantly related to the airflow patterns:the heating load in the case with ceiling supply air,where the supply air has a smaller contribution to the local zone,is 24%higher than that in the case with bottom supply air.(2)The degree of influence from each thermal boundary to the local zone of space cooling cases is close to that of a uniform environment,while the influence of each factor,particularly that of supply air,is non-uniformly distributed in space heating.(3)It is possible to enhance the influence of supply air and heat source with a reasonable airflow pattern to reduce the space heating load.In general,the findings of this study can be used to guide the energy savings of rooms with non-uniform environments for space cooling/heating. 展开更多
关键词 cooling/heating load non-uniform environment space cooling/heating temperature distribution building envelope
原文传递
Design and Implementation of Verification Code Identification Based on Anisotropic Heat Kernel 被引量:2
10
作者 LIU Lizhao LIU Jian +3 位作者 DAI Yaomei XU Huarong YIN Huayi ZHU Shunzhi 《China Communications》 SCIE CSCD 2016年第1期100-112,共13页
Many websites use verification codes to prevent users from using the machine automatically to register,login,malicious vote or irrigate but it brought great burden to the enterprises involved in internet marketing as ... Many websites use verification codes to prevent users from using the machine automatically to register,login,malicious vote or irrigate but it brought great burden to the enterprises involved in internet marketing as entering the verification code manually.Improving the verification code security system needs the identification method as the corresponding testing system.We propose an anisotropic heat kernel equation group which can generate a heat source scale space during the kernel evolution based on infinite heat source axiom,design a multi-step anisotropic verification code identification algorithm which includes core procedure of building anisotropic heat kernel,settingwave energy information parameters,combing outverification codccharacters and corresponding peripheral procedure of gray scaling,binarizing,denoising,normalizing,segmenting and identifying,give out the detail criterion and parameter set.Actual test show the anisotropic heat kernel identification algorithm can be used on many kinds of verification code including text characters,mathematical,Chinese,voice,3D,programming,video,advertising,it has a higher rate of 25%and 50%than neural network and context matching algorithm separately for Yahoo site,49%and 60%for Captcha site,20%and 52%for Baidu site,60%and 65%for 3DTakers site,40%,and 51%.for MDP site. 展开更多
关键词 verification code image recognition data mining scale space anisotropic heat kernel
下载PDF
Green heating:Theory and practice 被引量:1
11
作者 YANG YongPing LI PeiFeng +3 位作者 GE ZhiHua TIAN Jia WANG NingLing SONG ZhiPing 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2015年第12期2003-2015,共13页
Energy conservation in heating systems has great influence on overall sustainable development strategy. Heating technology, especially combined heat and power(CHP, cogeneration), has been attracting increased interest... Energy conservation in heating systems has great influence on overall sustainable development strategy. Heating technology, especially combined heat and power(CHP, cogeneration), has been attracting increased interest and rapidly developing in recent years. However, the theoretical potential of heating from the perspective of thermodynamics has not been clearly illustrated. This paper presents a theoretical analysis of heating systems based on the 1st and 2nd laws of thermodynamics using the specific fuel consumption(SFC) analysis method, clarifies the theoretical potential limitation of heating systems and illustrates the process of reversible heating on the basis of the total energy system. A novel concept(green heating, GH) and a new indicator(green-heating index, GH Index) are scientifically defined to characterise different options for heating and to quantitatively evaluate their fuel consumption levels. Thereafter, the fuel consumptions of four typical space heating modes are compared and discussed to present the application of GH theory and validate the power of the proposed concept and index. Furthermore, two different CHP technologies are analyzed with an instantiation case, and a novel CHP system is recommended, which may scientifically support the development of heating technology and further improve the processes of energy-saving and CO2 reduction. 展开更多
关键词 green heating combined heat and power space heating specific fuel consumption EXERGY THERMODYNAMICS
原文传递
A Dual-driven Intelligent Combination Control of Heat Pipe Space Cooling System 被引量:4
12
作者 LI Yunze LI Mingmin LEE Kok Meng 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2012年第4期566-574,共9页
Effective thermal control systems are essential for reliable operation of spacecraft.A dual-driven intelligent combination control strategy is proposed to improve the temperate control and heat flux tracking effects.B... Effective thermal control systems are essential for reliable operation of spacecraft.A dual-driven intelligent combination control strategy is proposed to improve the temperate control and heat flux tracking effects.Both temperature regulation and heat flux tracking errors are employed to generate the final control action;their contributions are adaptively adjusted by a fuzzy fusing policy of control actions.To evaluate the control effects,describe a four-nodal mathematical model for analyzing the dynamic characteristics of the controlled heat pipe space cooling system(HP-SCS) consisting of an aluminum-ammonia heat pipe and a variable-emittance micro-electromechanical-system(MEMS) radiator.This dynamical model calculates the mass flow-rate and condensing pressure of the heat pipe working fluid directly from the systemic nodal temperatures,therefore,it is more suitable for control engineering applications.The closed-loop transient performances of four different control schemes have been numerically investigated.The results conclude that the proposed intelligent combination control scheme not only improves the thermal control effects but also benefits the safe operation of HP-SCS. 展开更多
关键词 heat pipe space cooling system dynamic modeling intelligent combination control micro-electromechanical-system
原文传递
Experimental and Numerical Analysis of a PCM-Integrated Roof for Higher Thermal Performance of Buildings
13
作者 SIMON François RUIZ-VALERO Letzai +1 位作者 GIRARD Aymeric GALLEGUILLOS Hector 《Journal of Thermal Science》 SCIE EI CAS CSCD 2024年第2期522-536,共15页
Phase change materials(PCMs) designate materials able to store latent heat.PCMs change state from solid to liquid over a defined temperature range.This process is reversible and can be used for thermo-technical purpos... Phase change materials(PCMs) designate materials able to store latent heat.PCMs change state from solid to liquid over a defined temperature range.This process is reversible and can be used for thermo-technical purposes.The present paper aims to study the thermal performance of an inorganic eutectic PCM integrated into the rooftop slab of a test room and analyze its potential for building thermal management.The experiment is conducted in two test rooms in Antofagasta(Chile) during summer,fall,and winter.The PCM is integrated into the rooftop of the first test room,while the roof panel of the second room is a sealed air cavity.The work introduces a numerical model,which is built using the finite difference method and used to simulate the rooms' thermal behavior.Several thermal simulations of the PCM room are performed for other Chilean locations to evaluate and compare the capability of the PCM panel to store latent heat thermal energy in different climates.Results show that the indoor temperature of the PCM room in Antofagasta varies only 21.1℃±10.6℃,while the one of the air-panel room varies 28.3℃±18.5℃.Under the experiment's conditions,the PCM room's indoor temperature observes smoother diurnal fluctuations,with lower maximum and higher minimum indoor temperatures than that of the air-panel room.Thermal simulations in other cities show that the PCM panel has a better thermal performance during winter,as it helps to maintain or increase the room temperature by some degrees to reach comfort temperatures.This demonstrates that the implementation of such PCM in the building envelope can effectively reduce space heating and cooling needs,and improve indoor thermal comfort in different climates of Chile. 展开更多
关键词 phase change material thermal energy storage BUILDING space heating and cooling energy efficiency designbuilder
原文传递
Operational performance of a novel heat pump coupled with mini-channel PV/T and thermal panel in low solar radiation 被引量:4
14
作者 Jinzhi Zhou Xudong Zhao +3 位作者 Yanping Yuan Jing Li Min Yu Yi Fan 《Energy and Built Environment》 2020年第1期50-59,共10页
Here we describe a heat pump system coupled with novel PV/T and thermal panels for space heating in low solar radiation conditions.Existing solar indirect-expansion systems connect the solar panels and evaporator of t... Here we describe a heat pump system coupled with novel PV/T and thermal panels for space heating in low solar radiation conditions.Existing solar indirect-expansion systems connect the solar panels and evaporator of the heat pump in parallel with the heat storage tank.For our system these three components are instead connected in series,which can stabilize the temperature at the inlet of the evaporator and decrease the inlet temperature of the solar panels,leading to improved energy efficiency and the production of much more thermal energy.The experimental results of this system show that the average electrical,thermal and overall efficiency of the PV/T panels are 15.9%,33.4%and 49.3%,respectively.The average thermal efficiency of the thermal panels is 60.4%,the COP of heat pump is 4.7 and the room temperature is constantly over 18°C.Based on the experimental results,some improvements are analyzed.We conclude that this operating model can meet the requirement of space heating in low solar radiation environments. 展开更多
关键词 PV/T Thermal panel Heat pump Low solar radiation space heating
原文传递
Thermal Stability and Thermal Aging of Poly(vinyl chloride)/MgAl Layered Double Hydroxides Composites 被引量:6
15
作者 Hong-mei Zhang 张书华 +5 位作者 Polite Stewart Chen-hui Zhu Wei-jun Liu Alexander Hexemer Eric Schaible 王成 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2016年第5期542-551,共10页
MgAl-LDH(layered double hydroxides) were prepared with CO(NH2)2, NH4 Cl and NH3·H2O by the coprecipitation method, respectively. Corresponding composite membranes were prepared by the coating method. LDHs wer... MgAl-LDH(layered double hydroxides) were prepared with CO(NH2)2, NH4 Cl and NH3·H2O by the coprecipitation method, respectively. Corresponding composite membranes were prepared by the coating method. LDHs were characterized by WAXS, CO2-TPD and SEM. The morphology of the PVC/LDHs composite membranes were characterized by means of SEM. The thermal stability of the membranes was analyzed by air aging box and TGA-FTIR. The SEM results show that nano-particles can be compatible with poly(vinyl chloride)(PVC) matrix homogeneously by the stirring-ultrasound blend method with two steps. Furthermore, the air aging box results proved that MgAl-CO(NH2)2-LDH has the best effect on thermal stability of PVC. TGA-FTIR results show that MgAl-CO(NH2)2-LDH could adsorb more HCl that resulted from the degradation of PVC and improve the pyrolysis temperature of the first degradation stage by 15 K compared with PVC. 展开更多
关键词 vinyl layered compatible pyrolysis heating steps spacing interlayer dispersed blend
原文传递
Behavior of microbubbles on spatially controlled golden nanoparticles 被引量:1
16
作者 刘秀梅 焦明礼 《Chinese Optics Letters》 SCIE EI CAS CSCD 2016年第8期58-62,共5页
Incipient plasmonic bubble formation is observed around gold nanopillars with different inter-nanopillar separations. The experimental measurements and theoretical analysis show that the nanobubble formation is due to... Incipient plasmonic bubble formation is observed around gold nanopillars with different inter-nanopillar separations. The experimental measurements and theoretical analysis show that the nanobubble formation is due to the enhanced plasmonic resonance rather than from the laser heating. Inter-nanopillar distribution may lead to threshold fluence variations. The lifetime of plasmonic bubbles can reach several minutes. Furthermore, both the radius and the growth rate of the plasmonic nanobubble increase as the inter-nanopillar distribution decreases.Smaller-spacing distributed arrays produced larger bubbles. The maximum growth rate of the bubbles can be reached at about 883.5 × 10^-6m∕s on 1 μm nanopillars, but it is only 56.9 × 10^-6m∕s on 4 μm nanopillars. 展开更多
关键词 spatially golden bubble minutes spacing lifetime heating illumination radius camera
原文传递
上一页 1 下一页 到第