期刊文献+
共找到235篇文章
< 1 2 12 >
每页显示 20 50 100
A modified OMP method for multi-orbit three dimensional ISAR imaging of the space target
1
作者 JIANG Libing ZHENG Shuyu +2 位作者 YANG Qingwei YANG Peng WANG Zhuang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2023年第4期879-893,共15页
The conventional two dimensional(2D)inverse synthetic aperture radar(ISAR)imaging fails to provide the targets'three dimensional(3D)information.In this paper,a 3D ISAR imaging method for the space target is propos... The conventional two dimensional(2D)inverse synthetic aperture radar(ISAR)imaging fails to provide the targets'three dimensional(3D)information.In this paper,a 3D ISAR imaging method for the space target is proposed based on mutliorbit observation data and an improved orthogonal matching pursuit(OMP)algorithm.Firstly,the 3D scattered field data is converted into a set of 2D matrix by stacking slices of the 3D data along the elevation direction dimension.Then,an improved OMP algorithm is applied to recover the space target's amplitude information via the 2D matrix data.Finally,scattering centers can be reconstructed with specific three dimensional locations.Numerical simulations are provided to demonstrate the effectiveness and superiority of the proposed 3D imaging method. 展开更多
关键词 three dimensional inverse synthetic aperture radar(3D ISAR)imaging space target improved orthogonal matching pursuit(OMP)algorithm scattering centers
下载PDF
Review of Electronic Speckle Pattern Interferometry(ESPI) for Three Dimensional Displacement Measurement 被引量:22
2
作者 YANG Lianxiang XIE Xin +2 位作者 ZHU Lianqing WU Sijin WANG Yonghong 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第1期1-13,共13页
Three dimensional(3D) displacements, which can be translated further into 3D strain, are key parameters tor design, manufacturing and quality control. Using different optical setups, phase-shift methods, and algorit... Three dimensional(3D) displacements, which can be translated further into 3D strain, are key parameters tor design, manufacturing and quality control. Using different optical setups, phase-shift methods, and algorithms, several different 3D electronic speckle pattern interferometry(ESPl) systems for displacement and strain measurements have been achieved and commercialized. This paper provides a review of the recent developments in ESPI systems for 3D displacement and strain measurement. After an overview of the fundamentals of ESP! theory, temporal phase-shift, and spatial phase-shift techniques, 3D deformation measurements by the temporal phase-shift ESPI system, which is suited well for static measurement, and by the spatial phase-shift ESPI system, which is particularly useful for dynamic measurement, are discussed. For each method, the basic theory, a brief derivation and different optical layouts are presented. The state of art application, potential and limitation of the ESPI systems are shown and demonstrated. 展开更多
关键词 electronic speckle pattern interferometry(ESPI) three dimensional displacement and strain measurement static loading dynamic loading phase-shift technology
下载PDF
Three dimensional tectonic stress field in North China 被引量:6
3
作者 陈连旺 陆远忠 +2 位作者 张杰 许桂林 郭若眉 《Acta Seismologica Sinica(English Edition)》 CSCD 1999年第2期155-164,共10页
According to the latest data of geological structure, geophysics, in-situ stress measurement and focal mechanism,3-D tectonic stress field model in North China is built and 3-D tectonic stress field pattern of North C... According to the latest data of geological structure, geophysics, in-situ stress measurement and focal mechanism,3-D tectonic stress field model in North China is built and 3-D tectonic stress field pattern of North China aresimulated by finite element method. Then the overall characteristics and regional specific feature of North Chinaare studied. Finally, the influences of the valid dynamic boundary conditions of North China Block, active faultsand the inhomogeneity of crustal medium on tectonic stress field of North China are investigated. 展开更多
关键词 North China tectonic stress field three dimensional pattern numerical simulation by finite element method
下载PDF
Clinical significance of three dimensional finite element analysis on humerus fracture 被引量:15
4
作者 苏佳灿 张春才 +8 位作者 许硕贵 任可 王家林 薛召军 吴建国 丁祖泉 高堂成 万岷 付青格 《Journal of Medical Colleges of PLA(China)》 CAS 2002年第3期214-217,共4页
Objective: To treat humerus fracture with three dimensional pattern and finite element analysis, providing mechanical basis for treating humerus fracture. Methods: Humerus pattern was established based on the CT image... Objective: To treat humerus fracture with three dimensional pattern and finite element analysis, providing mechanical basis for treating humerus fracture. Methods: Humerus pattern was established based on the CT images, and calculation was done by ANSYS5. 6 software. Three dimensional ten-node tetrahedron unit was selected and were divided into 2 729 nodes, 49 041 units. Distribution and amount of axial compression of humerus were analyzed when clip angle was 30°, 45°, 90° between fracture face and axial line with fixed X, Y, Z directions. Results: The distribution of stress was greatly different between fracture face and non fracture face. Stress in fracture part was fairly concentrated with incomplete symmetric distribution around the center of fracture face; Greater stress distributed in the regions 10 mm from fracture face, which was 2-3 times that of other stress regions. Conclusion: Required load must be estimated under various conditions as to select the suitable internal fixation implants during the treatment of humerus fracture, which can provide helpful stress environment for fracture healing. 展开更多
关键词 humerus fracture t three dimensional finite element analysis
下载PDF
Modeling and validating three dimensional human normal cervix and cervical cancer tissues in vitro 被引量:1
5
作者 Anna Karolina Zuk Xuesong Wen +2 位作者 Stephen Dilworth Dong Li Lucy Ghali 《The Journal of Biomedical Research》 CAS CSCD 2017年第3期240-247,共8页
The use of three dimensional in vitro systems in cancer research is a promising path for developing effective anticancer therapies.The aim of this study was to engineer a functional 3-D in vitro model of normal and ca... The use of three dimensional in vitro systems in cancer research is a promising path for developing effective anticancer therapies.The aim of this study was to engineer a functional 3-D in vitro model of normal and cancerous cervical tissue.Normal epithelial and immortalized cervical epithelial carcinoma cell lines were used to construct 3-D artificial normal cervical and cervical cancerous tissues.De-epidermised dermis(DED) was used as a scaffold for both models.Morphological analyses were conducted by using hematoxylin and eosin staining and characteristics of the models were studied by analyzing the expression of different structural cytokeratins and differential protein marker MAX dimerisation protein 1(Mad1) using immunohistochemical technique.Haematoxylin and eosin staining results showed that normal cervical tissue had multi epithelial layers while cancerous cervical tissue showed dysplastic changes.Immunohistochemistry staining revealed that for normal cervix model cytokeratin 10 was expressed in the upper stratified layer of the epithelium while cytokeratin 5 was expressed mainly in the middle and basal layer.Cytokeratin 19 was weakly expressed in a few basal cells.Cervical cancer model showed cytokeratin 19 expression in different epithelial layers and weak or no expression for cytokeratin 5 and cytokeratin 10.Madl expression was detected in some suprabasal cells.The 3-D in vitro models showed stratified epithelial layers and expressed the same types and patterns of differentiation marker proteins as seen in corresponding in vivo tissue in either normal cervical or cervical cancerous tissue.These findings imply that they can serve as functional normal and cervical cancer models. 展开更多
关键词 cervical cancer MAX dimerisation protein 1 CYTOKERATINS three dimensional in vitro models
下载PDF
Use of three dimensional-printing in the management of floating aortic thrombus due to occult aortic dissection:A case report 被引量:1
6
作者 Tie-Hao Wang Ji-Chun Zhao +1 位作者 Fei Xiong Yi Yang 《World Journal of Clinical Cases》 SCIE 2021年第7期1755-1760,共6页
BACKGROUND Floating thrombus within the thoracic aorta is a rare entity but may cause systemic embolism.The pathogenesis of floating aortic thrombi is not yet fully understood.No definitive guidelines are available fo... BACKGROUND Floating thrombus within the thoracic aorta is a rare entity but may cause systemic embolism.The pathogenesis of floating aortic thrombi is not yet fully understood.No definitive guidelines are available for the management of floating aortic thrombus.CASE SUMMARY We report a 48-year-old patient,without a history of trauma and infection,who presented with sudden severe back pain.A floating thrombus within the aortic arch was found by computed tomography angiography(CTA).No evidence of coagulopathies was found.However,with the assistance of a three dimensionalprinted model,this floating thrombus was identified to be caused by occult aortic dissection(AD).Subsequently,an emergency thoracic endovascular repair was performed.The patient’s back pain was rapidly alleviated postoperatively.CTA at 1 year showed no filling defect in the stent-graft and aorta.CONCLUSION Occult AD is a potential factor causing floating aortic thrombi,endovascular stent-graft exclusion may be an optimal therapeutic choice with promising results.Moreover,the combination of CTA and three dimensional-printed models can contribute to the diagnosis and treatment of floating aortic thrombi due to occult AD. 展开更多
关键词 Floating thrombus Thoracic aorta Occult aortic dissection three dimensional printing Endovascular treatment Case report
下载PDF
Three dimensional finite element analysis of acetabulum loaded by static stress and its biomechanical significance 被引量:1
7
作者 苏佳灿 张本 +4 位作者 禹宝庆 张春才 陈学强 王保华 丁祖泉 《Journal of Medical Colleges of PLA(China)》 CAS 2005年第6期377-382,共6页
Objective:To explore the mechanical behavior of acetabulum loaded by static stress and provide the mechanical basis for clinical analysis and judgement on acetabular mechanical distribution and effect of static stress... Objective:To explore the mechanical behavior of acetabulum loaded by static stress and provide the mechanical basis for clinical analysis and judgement on acetabular mechanical distribution and effect of static stress.Methods:By means of computer simulation, acetabular three dimensional model was input into three dimensional finite element analysis software ANSYS7.0. The acetabular mechanical behavior was calculated and the main stress value, stress distribution and acetabular unit displacement in the direction of main stress were analyzed when anterior wall of acetabulum and acetabular crest were loaded by 1 000 N static stress. Results:When acetabular anterior wall loaded by X direction and Z direction composition force, the stress passed along 4 directions: (1)from acetabular anterior wall to pubic symphysis along superior branch of pubis firstly, (2)from acetabular anterior wall to cacroiliac joint along pelvic ring,(3)in the acetabulum,(4)from the suffered point to ischium. When acetabular crest loaded by X direction and Y direction composition force, the stress transmitted to 4 directions: (1)from acetabular crest to ilium firstly, (2)from suffered point to cacroiliac joint along pelvic ring,(3) in the acetabulum ,(4)along the pubic branch,but no stress transmitted to the ischium branch.Conclusion:Analyzing the stress distribution of acetabulum and units displacement when static stress loaded can provide internal fixation point for acetabular fracture treatment and help understand the stress distribution of acetabulum. 展开更多
关键词 ACETABULUM static stress stress analysis three dimensional finite element analysis
下载PDF
Research on dynamic updating of three dimensional geological modeling based on the OO-Solid model 被引量:1
8
作者 侯恩科 邓念东 +1 位作者 张志华 赵洲 《Journal of Coal Science & Engineering(China)》 2008年第3期420-424,共5页
The dynamic updating of the model included: the change of space border,addi- tion and reduction of spatial component (disappearing,dividing and merging),the change of the topological relationship and synchronous dynam... The dynamic updating of the model included: the change of space border,addi- tion and reduction of spatial component (disappearing,dividing and merging),the change of the topological relationship and synchronous dynamic updating of database.Firstly, arming at the deficiency of OO-Solid model in the aspect of dynamic updating,modeling primitives of OO-Solid model were modified.And then the algorithms of dynamic updating of 3D geological model with the node data,line data or surface data change were dis- cussed.The core algorithms was done by establishing space index,following the way of facing the object from bottom to top,namely the dynamic updating from the node to arc, and then to polygon,then to the face of the component and finally to the geological object. The research has important theoretical and practical values in the field of three dimen- sional geological modeling and is significant in the field of mineral resources. 展开更多
关键词 digital mine three dimensional geological modeling OO-Solid model dynamic updating
下载PDF
A study of transarterial infusion chemotherapy of gemcitabine plus three dimensional conformal radiotherapy for local advanced pancreatic cancer 被引量:1
9
作者 Zhaojun Ding Yanwei Sun Jiayun Zhou 《The Chinese-German Journal of Clinical Oncology》 CAS 2007年第3期237-240,共4页
Objective: To evaluate the clinical effect of transarterial infusion chemotherapy of gemcitabine plus three dimen- sional conformal radiotherapy on patients with local advanced pancreatic cancer. Methods: Fifty-one pa... Objective: To evaluate the clinical effect of transarterial infusion chemotherapy of gemcitabine plus three dimen- sional conformal radiotherapy on patients with local advanced pancreatic cancer. Methods: Fifty-one patients with local ad- vanced pancreatic cancer from June 2002 to February 2004 were enrolled, twenty-four patients of combined group were treat- ed with transarterial infusion chemotherapy of gemcitabine plus three dimensional conformal radiotherapy, while twenty-seven patients of control group were treated only with transarterial infusion chemotherapy of gemcitabine. Results: There were significant statistical differences between two groups in clinical benefit response (91.7% versus 74.1%, P < 0.01) and overall remission rate (70.8% versus 33.3%, P < 0.01). The 6-month survival rate, 12-month survival rate and 24-month survival rate of combined group were 83.3%, 62.5% and 37.5% respectively, while that of control group were 55.6%, 33.3% and 11.1% respectively. This showed significant difference between the two groups. Conclusion: Transarterial infusion chemotherapy of gemcitabine plus three dimensional conformal radiotherapy may be better than single transarterial infusion chemotherapy of gemcitabine in improving survival rates and elongating survival time of patients with local advanced pancreatic cancer. 展开更多
关键词 three dimensional conformal radiotherapy pancreatic cancer transarterial infusion CHEMOTHERAPY
下载PDF
Impact of three dimensional printing in orthopedics 被引量:1
10
作者 Lalit Kumar Abid Haleem Mohd.Javaid 《Global Health Journal》 2021年第4期178-182,共5页
The primary objective of this article is to explore effects of latest development in the area of three dimensional(3D)printing&to assess its abilities,and further undertake helpful reporting.Here the focus is to a... The primary objective of this article is to explore effects of latest development in the area of three dimensional(3D)printing&to assess its abilities,and further undertake helpful reporting.Here the focus is to assess ad vantages of 3D printing in orthopedics and analyze how 3D printed models help solve complex 3D orthopedics distortions.This study identified that 3D models manufactured by 3D printing models reduce medical parts de velopment cost and surgical planning time.Integrating 3D printing with orthopaedics helps in understanding the conditions of problems and achieving the operation succssfully.This technology can enable doctors/surgeons to design,produce,recreate and plan operations more accurately,carefully,and economicaly.3D models can assist specialists with a visual comprehension of the patient-particular pathology and life structures.Innovation in 3D printing initiated a scaffold for the virtual outline and execution of medical procedures.This research proposes the utilisation of 3D printers as an elective procedure for the fabrication of parts.It empowers surgeons/patients for better raining,education and research.In the future,there is a foreseeable expansion of additive manufacturing in orthopedics. 展开更多
关键词 three dimensional(3D)printing 3D model Future capabilities Medical implant ORTHOPEDICS
下载PDF
Approach to Power Spectrum Density Values in Three Dimensional Acceleration of Ground Motions
11
作者 Luo, Chuanxin Zhu, Ke Zhang, Lifu 《China Ocean Engineering》 SCIE EI 1993年第4期417-424,共8页
In this paper, based on the random characteristic analysis of Tianjin Hospital earthquake waves of Tangshan aftershock, the three dimensional acceleration power spectrum density ratio has been presented.
关键词 ACCELERATION CALCULATIONS Earthquake resistance EARTHQUAKES Ocean engineering Offshore structures Random processes Seismic waves Structural analysis three dimensional White noise
下载PDF
The analysis of complex behaviours of a novel three dimensional autonomous system
12
作者 董高高 郑松 +2 位作者 田立新 杜瑞瑾 孙梅 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期156-166,共11页
This paper introduces a new three dimensional autonomous system with five equilibrium points. It demonstrates complex chaotic behaviours within a wide range of parameters, which are described by phase portraits, Lyapu... This paper introduces a new three dimensional autonomous system with five equilibrium points. It demonstrates complex chaotic behaviours within a wide range of parameters, which are described by phase portraits, Lyapunov exponents, frequency spectrum, etc. Analysis of the bifurcation and Poincar@ map is used to reveal mechanisms of generating these complicated phenomena. The corresponding electronic circuits are designed, exhibiting experimental chaotic attractors in accord with numerical simulations. Since frequency spectrum analysis shows a broad frequency bandwidth, this system has perspective of potential applications in such engineering fields as secure communication. 展开更多
关键词 three dimensional autonomous system chaotic attractor electronic circuit frequency spectrum
下载PDF
MHD three dimensional flow of viscoelastic fluid with thermal radiation and variable thermal conductivity
13
作者 SHEHZAD S A HAYAT T ALSAEDI A 《Journal of Central South University》 SCIE EI CAS 2014年第10期3911-3917,共7页
The objective of the present work is to model the magnetohydrodynamic(MHD) three dimensional flow of viscoelastic fluid passing a stretching surface. Heat transfer analysis is carried out in the presence of variable t... The objective of the present work is to model the magnetohydrodynamic(MHD) three dimensional flow of viscoelastic fluid passing a stretching surface. Heat transfer analysis is carried out in the presence of variable thermal conductivity and thermal radiation. Arising nonlinear analysis for velocity and temperature is computed. Discussion to importantly involved parameters through plots is presented. Comparison between present and previous limiting solutions is shown. Numerical values of local Nusselt number are computed and analyzed. It can be observed that the effects of viscoelastic parameter and Hartman number on the temperature profile are similar in a qualitative way. The variations in temperature are more pronounced for viscoelastic parameter K in comparison to the Hartman number M. The parameters N and ε give rise to the temperature. It is interesting to note that values of local Nusselt number are smaller for the larger values of ε. 展开更多
关键词 three dimensional flow viscoelastic fluid variable thermal conductivity thermal radiation
下载PDF
The Properties of an UV Curable Support Material Pre-polymer for Three Dimensional Printing
14
作者 黄兵 莫健华 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2010年第2期278-281,共4页
An ultraviolet(UV) curable support material pre-polymer for three dimensional printing was prepared based on the synergistic effect between PEO-PPO-PEO tri-block copolymer(F127) and polyethylene glycol (400) di-... An ultraviolet(UV) curable support material pre-polymer for three dimensional printing was prepared based on the synergistic effect between PEO-PPO-PEO tri-block copolymer(F127) and polyethylene glycol (400) di-acrylate(SR344). The effects of jetting conditions, thermal stability, curing time, mechanical properties and shrinking rate on printing models were studied. The situation of removing support material from build model was investigated after building progress was completed. The experimental result shows that when F127 is 6.0wt%, SR344 is 20.0wt%, 4-Methoxy phenol is 0.15wt% and Irgacure 2959 is 1.5wt%, the support material pre-polymer could be jetted out from the nozzles smoothly during building up of three dimensional printing models at 50-55 ℃. In addition, the support material could be removed easily from building model without spoiling the model; furthermore, the forming precision of building model is improved. 展开更多
关键词 three dimensional printing support material synergistic effect forming precision
下载PDF
Three dimensional particles identification and shape parameters research on coarse aggregates of asphalt mixture using X-ray CT images
15
作者 段跃华 张肖宁 +1 位作者 张顺先 苑苗苗 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第5期103-107,共5页
In this paper a series of digital image processing methods were adopted for getting separated coarse aggregates from asphalt mixture specimen using high-resolution X-ray Computed Tomography (CT) images.The existing th... In this paper a series of digital image processing methods were adopted for getting separated coarse aggregates from asphalt mixture specimen using high-resolution X-ray Computed Tomography (CT) images.The existing three dimensional (3D) particles matching methods based on two dimensional (2D) continuous cross-sections were analyzed and a new 'overlap area method' was presented.After the 3D particles were extracted one by one successfully,the basic parameters of each aggregate:perimeter,area,surface area,and volume were calculated by chain code method.Finally,the 3D mass center coordinates and the sphericity index were introduced. 展开更多
关键词 asphalt mixture X-ray CT three dimensional matching chain code SPHERICITY
下载PDF
BMRMIA:A Platform for Radiologists to Systematically Learn Automated Medical Image Analysis by Three Dimensional Medical Decision Support System
16
作者 Yankun Cao Lina Xu +5 位作者 Zhi Liu Xiaoyan Xiao Mingyu Wang Qin Li Hongji Xu Geng Yang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2022年第5期851-863,共13页
Contribution:This paper designs a learning and training platform that can systematically help radiologists learn automated medical image analysis technology.The platform can help radiologists master deep learning theo... Contribution:This paper designs a learning and training platform that can systematically help radiologists learn automated medical image analysis technology.The platform can help radiologists master deep learning theories and medical applications such as the three-dimensional medical decision support system,and strengthen the teaching practice of deep learning related courses in hospitals,so as to help doctors better understand deep learning knowledge and improve the efficiency of auxiliary diagnosis.Background:In recent years,deep learning has been widely used in academia,industry,andmedicine.An increasing number of companies are starting to recruit a large number of professionals in the field of deep learning.Increasing numbers of colleges and universities also offer courses related to deep learning to help radiologists learn automated medical image analysis techniques.For now,however,there is no practical training platform that can help radiologists learn automated medical image analysis systematically.ApplicationDesign:The platform proposes the basic learning,model combat,business application(BMR)concept,including the learning guidance system and the assessment training system,which constitutes a closed-loop learning guidance mode of“learning-assessment-training-learning”.Findings:The survey results show that most of radiologists met their learning expectations by using this platform.The platform can help radiologists master deep learning techniques quickly,comprehensively and firmly. 展开更多
关键词 BMR deep learning three dimensional medical decision support system deep learning engineer standard
下载PDF
SYNTHESIS AND CRYSTAL STRUCTURE OF THE FIRST THREE DIMENSIONAL NETWORK CU(Ⅱ) COMPLEX BRIDGED BY BOTH OXAMIDE AND AZIDE
17
作者 Zhong Ning CHEN Zhong Gui WU Wen Xia TANG State Key Laboratory of Coordination Chemistry, Nanjing University, Nanjing 210008 Kai Bei YU Analysis Center, Chengdu Branch of Chinese Academy of Science, Chengdu 610041 《Chinese Chemical Letters》 SCIE CAS CSCD 1993年第11期1029-1030,共2页
A novel three dimensional network complex polymer [Cu_4(oxen)_2(N_3)_3]_n(ClO_4)_n·2nH_2O, where oxen is N,N' -bis(2-aminoethyl)oxamide dianion, has been synthesized. It crystallizes in triclinic system, spac... A novel three dimensional network complex polymer [Cu_4(oxen)_2(N_3)_3]_n(ClO_4)_n·2nH_2O, where oxen is N,N' -bis(2-aminoethyl)oxamide dianion, has been synthesized. It crystallizes in triclinic system, space group P, with a=11.486(2), b=11.706(3), c=12.291(3) , α=77.42(2), β=67.59(2), γ=77.96(2)°, and z=2. The least-square refinements converged at R=0.047, with 3416 observed unique reflections. The complex has a pronounced three-dimensional character and can be viewed as the tetranuclear asymmetric repeating units through inversion and translation operations to extend a three-dimensional network. The structure of Cu_4 asymmetric unit consists of two square planar and two square pyramidal Cu central atoms linked by both azide ligands in end-on and end-to-end bonding modes, and oxamidate bridge in trans conformation. 展开更多
关键词 CU mode COMPLEX BRIDGED BY BOTH OXAMIDE AND AZIDE SYNTHESIS AND CRYSTAL STRUCTURE OF THE FIRST three dimensional NETWORK CU
下载PDF
Geometric comparison of the mitral and tricuspid valve annulus:Insights from three dimensional transesophageal echocardiography
18
作者 Amgad N Makaryus Haisam Ismail +1 位作者 John N Makaryus Dali Fan 《World Journal of Cardiology》 CAS 2017年第9期757-760,共4页
AIM To apply real time three-dimensional transesophageal echocardiography(RT3D TEE) for quantitative and qualitative assessment of the mitral valve annulus(MVA) and tricuspid valve annulus(TVA) in the same patient.MET... AIM To apply real time three-dimensional transesophageal echocardiography(RT3D TEE) for quantitative and qualitative assessment of the mitral valve annulus(MVA) and tricuspid valve annulus(TVA) in the same patient.METHODS Our retrospective cohort study examined the MVA and TVA in 49 patients by RT3 D TEE. MVA and TVA shape were examined by TEE. The MVA and TVA volume data set images were acquired in the mid esophageal 4-chamber view. The MVA and TVA were acquired separately, with optimization of each for the highest frame rate and image quality. The 3D shape of the annuli was reconstructed using the Philips~? Q lab, MVQ ver. 6.0 MVA model software. The end-systolic frame was used. The parameters measured and compared were annular area, circumference, high-low distances(height), anterolateralposterolateral(ALPM), and anteroposterior(AP) axes. RESULTS A total of 49 patients(mean age 61 ± 14 years, 45% males) were studied. The ALPM and the AP axes of the MVA and TVA are not significantly different. The ALPM axis of the MVA was 37.9 ± 6.4 mm and 38.0 ± 5.6 mm for the TVA(P = 0.70). The AP axis of the MVA was 34.8 ± 5.7 mm and 34.9 ± 6.2 mm for the TVA(P = 0.90). The MVA and the TVA had similar circumference and area. The circumference of the MVA was 127.9 ± 16.8 mm and 125.92 ± 16.12 mm for the TVA(P = 0.23). The area of the MVA was 1103.7 ± 307.8 mm^2 and 1131.7 ± 302.0 mm^2 for the TVA(P = 0.41). The MVA and TVA are similar oval structures, but with significantly different heights. The ALPM/AP ratio for the MVA was 1.08 ± 0.33 and 1.09 ± 0.28 for the TVA(P < 0.001). The height for the MVA and TVA was 9.23 ± 2.11 mm and 4.37 ± 1.48 mm, respectively(P < 0.0001). CONCLUSION RT3 D TEE plays an unprecedented role in the management of valvular heart disease. The specific and exclusive shape of the MVA and TVA was revealed in our study of patients studied. Moreover, the intricate codependence of the MVA and the TVA depends on their distinctive shapes. This realization seen from our study will allow us to better understand the role valvular disease plays in disease states such as hypertrophic cardiomyopathy and pulmonary hypertension. 展开更多
关键词 Mitral valve annulus Tricuspid valve annulus three dimensional imaging Real time three-dimensional transesophageal echocardiography
下载PDF
Three Dimensional Simulation of Upset Forging by Using Variational Upper Bound Method
19
作者 Jiang QIN(School of Mechanical Engineering, University of Bath, Claverton Down, Bath BA27AY, UK) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1994年第1期15-22,共8页
The variation principle is discussed and Rayleigh-Ritz method is proposed for construction of veloci ty field. A kinematically admissible velocity field based on polynomials was appIied to the determina tion of forgin... The variation principle is discussed and Rayleigh-Ritz method is proposed for construction of veloci ty field. A kinematically admissible velocity field based on polynomials was appIied to the determina tion of forging load and deformed buIge profile during upset forging of blocks. Simulation of upsetforging of rectangular blocks under various friction condjtions was performed. Comparison of the computed results with experiments and FEM shows good agreement. It is shown that this techniquecan be used for 3D simulation of metal forming process. 展开更多
关键词 SIMULATION three dimensional Simulation of Upset Forging by Using Variational Upper Bound Method ASME
下载PDF
Clinical study of three dimensional conformal radiotherapy combined with intracavitary brachytherapy in the treatment of cervical cancer
20
作者 Yeqin Zhou Daiyuan Ma Tao Ren Xianfu Li Jing Hu Bangxian Tan 《The Chinese-German Journal of Clinical Oncology》 CAS 2011年第6期340-343,共4页
Objective: The aim of our study was to evaluate the outcome and complications of cervical cancer patients undergoing conventional intracavitary brachytherapy (ICBT) treated with 3D-conformal radiotherapy (3DCRT). Meth... Objective: The aim of our study was to evaluate the outcome and complications of cervical cancer patients undergoing conventional intracavitary brachytherapy (ICBT) treated with 3D-conformal radiotherapy (3DCRT). Methods: Sixty cervical cancer patients were divided randomly into the conformal group and the conventional group. Thirty patients treated with 3D-conformal radiotherapy in the 3DCRT group, when the whole pelvic received DT 40 Gy, a planning CT scan of each patient was obtained and the second 3DCRT therapy plan was taken. Then, continued to irradiate to 50 Gy. At last, 3DCRT was boosted at local involved volumes to the total dose of 60 Gy. When 3DCRT was combined with intracavitary brachytherapy, the dose of brachytherapy to point A was 30 Gy/5 fractions. In the conventional group, after a total tumor dose of 40 Gy was delivered by the whole pelvic irradiation, the four-field technique was used to irradiate the total pelvic and regional nodes (median dose of 10 Gy), and the involved volumes were boosted to 60 Gy and the dose of brachytherapy to point A was 30 Gy-36 Gy/5-6 fractions. Moreover, both groups were combined with intracavitary brachytherapy respectively. Results: The 1, 2, 3-year survival rates for the 3DCRT group and the conventional group were 96.7%, 93.3%, 90.0% and 86.6%, 76.7%, 70% respectively (P = 0.04, P = 0.02 and P = 0.02). There was a statistically significant difference between the two groups. Compared to the two groups each other in toxic effects, except for the I-II grade rectal and bladder reaction and pelvic fibrosis which was lower in the 3DCRT group (P = 0. 007, P = 0. 006 and P = 0. 015), the side effects were similar and well tolerated in two groups. Conclusion: The all-course 3DCRT combined with intracavitary brachytherapy can be considered as an effective and feasible approach to cervical cancer and may significantly improve the survival rate and reduce the late toxicity. This new role for 3DCRT merits need further evaluation with large patient numbers and longer follows up. 展开更多
关键词 cervical cancer external radiotherapy three dimensional conformal radiotherapy CHEMOTHERAPY intracavitary brachytherapy
下载PDF
上一页 1 2 12 下一页 到第
使用帮助 返回顶部