AIM: To evaluate the intra-operator repeatability of time domain and swept-source Fourier domain anterior segment optical coherence tomography(AS-OCT), namely, Visante ASOCT and Casia SS-1000 OCT, in measuring the pre...AIM: To evaluate the intra-operator repeatability of time domain and swept-source Fourier domain anterior segment optical coherence tomography(AS-OCT), namely, Visante ASOCT and Casia SS-1000 OCT, in measuring the preoperative parameters of implantable collamer lens(ICL) in myopic eyes, as well as the agreement between the two devices.METHODS: A total of 97 eyes from 49 myopes were investigated in this prospective case series study. The anterior chamber depth(ACD), angle-to-angle distance(ATA), pupil diameter(PD) and crystalline lens rise(CLR) in all subjects were measured for three times during one session by the same operator. The repeatability was evaluated using the within-subject standard deviation(Sw), repeatability limits and intraclass correlation coefficients(ICC). The agreement between the two systems was evaluated using the Bland-Altman plots and 95% limits of agreement(Lo A).RESULTS: The repeatability limits of Visante AS-OCT in measuring ACD, ATA, PD and CLR were 0.099, 0.141, 0.304, and 0.079 mm, respectively. The repeatability limits of Casia SS-1000 OCT in measuring ACD, ATA, PD, and CLR were 0.105, 0.127, 0.357, and 0.082 mm, respectively. Excellent repeatability could be attained in both devices, with the ICC>0.8 for all the measured variables. The interdevice agreement was excellent(P>0.05) for ACD and ATA, but poor(P<0.05) for PD and CLR.CONCLUSION: Good repeatability can be attained by time domain and swept-source Fourier-domain OCT for all the measured variables. Moreover, interdevice agreement analysis suggests that interchangeable measurements between two devices can be achieved for ACD and ATA, but not for PD and CLR;but the differences in measurements were not clinically significant.展开更多
AIM:To evaluate the measurements of anterior segment parameters using three different non-contact optical devices in keratoconus patients.·METHODS:A hundred and one eyes of 55 keratoconus patients were enrolled i...AIM:To evaluate the measurements of anterior segment parameters using three different non-contact optical devices in keratoconus patients.·METHODS:A hundred and one eyes of 55 keratoconus patients were enrolled in this study.The mean age was26.2 ±8.9 years.The inclusion criteria were keratoconus stage I to III according to the Amsler-Krumeich keratoconus classification.All the measurements were done by the same operator,under the mesopic light condition and repeated with three different optical methods;Visante,Orbscan and Pentacam.The evaluated anterior segment parameters were anterior chamber depth(ACD),central and thinnest corneal thickness(CCT and TCT) and pupil diameter(PD).·RESULTS:The mean CCT measured by Visante,Orbscan and Pentacam were as follows:462.0 ±48.1μm,463.9±60.9μm,476.5±45.3μm,respectively(P =0.873).The mean ACD values were 3.34±0.33mm,3.26±0.33mm,3.49±0.40mm,respectively(P=0.118).The mean PD measurements were 5.11 ±1.14mm,4.80 ±0.85mm,3.80 ±1.38mm,respectively(P 【0.001).The mean TCT measurements of Visante,Orbscan and Pentacam were 437.9 ±48.2μm,447.6±60.6μm and 459.9±44.0μm,respectively(P =0.214).The Visante and Orbscan measured CCT similarly,while Pentacam measured CCT thicker than the other two.The Visante measured TCT thinner than the other two devices.In ACD measurements,Orbscan was the one giving the lowest values.PD was measured differently by the devices.·CONCLUSION:Although TCT,CCT and ACD measurements acquired by Visante,Orbscan and Pentacam in keratoconus patients are similar,PDmeasurements show large differences among the devices.展开更多
基金Supported by the Priming Scientific Research Foundation for the junior researcher in Beijing Tongren Hospital,Capital Medical University(No.2018-YJJ-ZZL-034)。
文摘AIM: To evaluate the intra-operator repeatability of time domain and swept-source Fourier domain anterior segment optical coherence tomography(AS-OCT), namely, Visante ASOCT and Casia SS-1000 OCT, in measuring the preoperative parameters of implantable collamer lens(ICL) in myopic eyes, as well as the agreement between the two devices.METHODS: A total of 97 eyes from 49 myopes were investigated in this prospective case series study. The anterior chamber depth(ACD), angle-to-angle distance(ATA), pupil diameter(PD) and crystalline lens rise(CLR) in all subjects were measured for three times during one session by the same operator. The repeatability was evaluated using the within-subject standard deviation(Sw), repeatability limits and intraclass correlation coefficients(ICC). The agreement between the two systems was evaluated using the Bland-Altman plots and 95% limits of agreement(Lo A).RESULTS: The repeatability limits of Visante AS-OCT in measuring ACD, ATA, PD and CLR were 0.099, 0.141, 0.304, and 0.079 mm, respectively. The repeatability limits of Casia SS-1000 OCT in measuring ACD, ATA, PD, and CLR were 0.105, 0.127, 0.357, and 0.082 mm, respectively. Excellent repeatability could be attained in both devices, with the ICC>0.8 for all the measured variables. The interdevice agreement was excellent(P>0.05) for ACD and ATA, but poor(P<0.05) for PD and CLR.CONCLUSION: Good repeatability can be attained by time domain and swept-source Fourier-domain OCT for all the measured variables. Moreover, interdevice agreement analysis suggests that interchangeable measurements between two devices can be achieved for ACD and ATA, but not for PD and CLR;but the differences in measurements were not clinically significant.
文摘AIM:To evaluate the measurements of anterior segment parameters using three different non-contact optical devices in keratoconus patients.·METHODS:A hundred and one eyes of 55 keratoconus patients were enrolled in this study.The mean age was26.2 ±8.9 years.The inclusion criteria were keratoconus stage I to III according to the Amsler-Krumeich keratoconus classification.All the measurements were done by the same operator,under the mesopic light condition and repeated with three different optical methods;Visante,Orbscan and Pentacam.The evaluated anterior segment parameters were anterior chamber depth(ACD),central and thinnest corneal thickness(CCT and TCT) and pupil diameter(PD).·RESULTS:The mean CCT measured by Visante,Orbscan and Pentacam were as follows:462.0 ±48.1μm,463.9±60.9μm,476.5±45.3μm,respectively(P =0.873).The mean ACD values were 3.34±0.33mm,3.26±0.33mm,3.49±0.40mm,respectively(P=0.118).The mean PD measurements were 5.11 ±1.14mm,4.80 ±0.85mm,3.80 ±1.38mm,respectively(P 【0.001).The mean TCT measurements of Visante,Orbscan and Pentacam were 437.9 ±48.2μm,447.6±60.6μm and 459.9±44.0μm,respectively(P =0.214).The Visante and Orbscan measured CCT similarly,while Pentacam measured CCT thicker than the other two.The Visante measured TCT thinner than the other two devices.In ACD measurements,Orbscan was the one giving the lowest values.PD was measured differently by the devices.·CONCLUSION:Although TCT,CCT and ACD measurements acquired by Visante,Orbscan and Pentacam in keratoconus patients are similar,PDmeasurements show large differences among the devices.