期刊文献+
共找到18篇文章
< 1 >
每页显示 20 50 100
Impact of summer office set air-conditioning temperature on energy consumption and thermal comfort 被引量:3
1
作者 刘红 马小磊 高亚峰 《Journal of Central South University》 SCIE EI CAS 2009年第S1期6-11,共6页
To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three... To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three similar offices at temperatures of 24,26 and 28 ℃ respectively. A thermal comfort questionnaire survey was conducted. It is demonstrated that air-conditioner energy consumption at the set temperature of 28 ℃ is 113% and 271% lower than at 26 ℃ and 24 ℃,respectively. A linear relationship exists between air-conditioner energy consumption and the indoor and outdoor temperature difference. When comfortably dressed,over 80% of research participants accept the set temperature of 28 ℃. The regression analysis leads to a neutral temperature of 26.2 ℃ and an acceptable temperature of 28.2 ℃ for over 80% of the research participants subjects,indicating that the current 26 ℃ set temperature for offices in summer,required by Chinese General Office of the State Council,can be increased to 28 ℃. Moreover,analysis of predicted mean vote(PMV) index shows that a set temperature of 27 ℃,not 26 ℃,is sufficiently comfortable for office staff wearing long-sleeve shirts,long pants and leather shoes. 展开更多
关键词 air-conditionING TEMPERATURE thermal COMFORT air-conditionER energy consumption NEUTRAL TEMPERATURE acceptable TEMPERATURE
下载PDF
Influence of Surrounding Structures upon the Aerodynamic and Acoustic Performance of the Outdoor Unit of a Split Air-Conditioner 被引量:3
2
作者 WU Chengjun LIU Jiang PAN Jie 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第4期836-845,共10页
DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structu... DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structures upon the aerodynamic and acoustic performance, however they are only limited to the influence of a few parameters on the performance, and practical design of the unit requires more detailed parametric analysis. Three-dimensional computational fluid dynamics(CFD) and computational aerodynamic acoustics(CAA) simulation based on FLUENT solver is used to study the influence of surrounding structures upon the aforementioned properties of the unit. The flow rate and sound pressure level are predicted for different rotating speed, and agree well with the experimental results. The parametric influence of three main surrounding structures(i.e. the heat sink, the bell-mouth type shroud and the outlet grille) upon the aerodynamic performance of the unit is analyzed thoroughly. The results demonstrate that the tip vortex plays a major role in the flow fields near the blade tip and has a great effect on the flow field of the unit. The inlet ring's size and throat's depth of the bell-mouth type shroud, and the through-flow area and configuration of upwind and downwind sections of the outlet grille are the most important factors that affect the aerodynamic performance of the unit. Furthermore, two improved schemes against the existing prototype of the unit are developed, which both can significantly increase the flow rate more than 6 %(i.e. 100 m3·h~(-1)) at given rotating speeds. The inevitable increase of flow noise level when flow rate is increased and the advantage of keeping a lower rotating speed are also discussed. The presented work could be a useful guideline in designing the aerodynamic and acoustic performance of the split air-conditioner in engineering practice. 展开更多
关键词 DC-inverter split air-conditioner outdoor unit surrounding structure computational fluid dynamics(CFD) computational aerodynamic acoustics(CAA) simulation improved design
下载PDF
Environmental Benefits for Phase-Out HCFC-22 in the Residential Air-Conditioner Sector in China 被引量:1
3
作者 Tingting Wan Yanwei Dou +4 位作者 Lei Wang Lirong Yang Xiaofang Zhou Dan Wan Jianxin Hu 《Advances in Climate Change Research》 SCIE 2011年第2期86-92,共7页
China is the largest producer and consumer of hydrochlorofluorocarbons (HCFCs), and the production of HCFC-22 accounts for more than 80% of all HCFCs. This paper concentrates on the residential air-conditioner indus... China is the largest producer and consumer of hydrochlorofluorocarbons (HCFCs), and the production of HCFC-22 accounts for more than 80% of all HCFCs. This paper concentrates on the residential air-conditioner industry and analyzes the environmental benefits of accelerating the phase-out of HCFC-22 in China. According to the comparison of the baseline and phase-out scenarios of HCFC-22, the findings show that using HC-290 (propane) as a refrigerant alternative will directly reduce the greenhouse effect, and indirectly reduce the emission of greenhouse gases due to a reduction in the electricity consumption. The comparison of two scenarios of HC-290 and HFC-410A refrigerant alternatives shows that the use of HC-290 refrigerant will produce significantly higher environmental benefits than the HFC-410A refrigerant. 展开更多
关键词 HCFC-22 HFC-410A HC-290 residential air-conditioner GWP ODP
下载PDF
Forecast of Consumption and Emission of HFC-134a Used in the Mobile Air-conditioner Sector in China 被引量:1
4
作者 Jianxin Hu Dan Wan +2 位作者 Chunmei Li Jianbo Zhang Xu Yi 《Advances in Climate Change Research》 SCIE 2010年第1期20-26,共7页
HFC-134a is the most important alternative to CFC-12 used in the mobile air-conditioner sector in China. The con- sumption of HFC-134a has been increasing rapidly in recent years. It becomes the most consumed HFC in t... HFC-134a is the most important alternative to CFC-12 used in the mobile air-conditioner sector in China. The con- sumption of HFC-134a has been increasing rapidly in recent years. It becomes the most consumed HFC in the sector. Selecting 2005 as the base line year, future consumption and emission amounts of HFC-134a are estimated through an analysis of a combined scenario: 1) replacement by non-HFC-134a blends, 2) good practice in servicing, 3) technology promotion, and 4) government policies on control of HFC-134a emissions. The analysis shows that HFC-134a consumption and emissions will continue to increase in the next 10 years. The projected HFC-134a consumption will approach 20,150 t and 34,875 t in 2010 and 2015 respectively, while the estimated emission amounts will reach 16,065 t and 30,186 t (i.e., 21 Mt CO2-eq and 39 Mt CO2-eq emissions) correspondingly. Compared with the business-as-usual scenario, the expected emission reductions in 2010 and 2015 will range between 6.7 Mt CO2-eq and 13.0 Mt CO2-eq. 展开更多
关键词 mobile air-conditioner HFC-134A emission reduction
下载PDF
A Novel Concept of AI-EV (Air-Conditioner Integrated Electric Vehicle) for the Advanced Smart Community 被引量:1
5
作者 Yu Notoji Tsuguhiko Nakagawa 《Journal of Energy and Power Engineering》 2014年第11期1933-1941,共9页
In order to expand the natural energy and the energy conservation, "the smart PV (photovoltaic power generation) & EV (electric vehicle) system" has been proposed and the effect has been clarified. In the smart... In order to expand the natural energy and the energy conservation, "the smart PV (photovoltaic power generation) & EV (electric vehicle) system" has been proposed and the effect has been clarified. In the smart PV & EV system, it is important that electric vehicles become popular. Therefore, the AI-EV (air-conditioner integrated electric vehicle) has been proposed. In this paper, the AI-EV is designed based on the required car air-conditioner capacity. And, the value of AI-EV is compared with a gasoline vehicle, HV (hybrid vehicle) and EV using the mathematical simulation model As a result, it is clarified that the minimum displacement of the small-engine is 120 cc for AI-EV. In the smart PV & EV system, AI-EV can reduce CO_2 emissions by 20% almost the same as EV. Additionally, AI-EV is able to gain the cruising range more than twice as long as EV. 展开更多
关键词 Electric vehicle air-conditionER CO_2 emissions smart community.
下载PDF
Effect of air-conditioner exposure on semen quality
6
作者 Min-LiLu Jun-QingWu +2 位作者 Qiu-YingYang Wei-JinZhou Er-ShengGao 《Asian Journal of Andrology》 SCIE CAS CSCD 2004年第4期354-354,共1页
Aim: To investigate the effect of air-conditioner exposure on semen quality. Methods: The data came from the healthy male volunteers, aged 22 to 30 years, who went to centers for maternity and children health for prem... Aim: To investigate the effect of air-conditioner exposure on semen quality. Methods: The data came from the healthy male volunteers, aged 22 to 30 years, who went to centers for maternity and children health for premarital physical examination in Shanghai, Henan, Zhejiang and Hebei from December 1998 to February 2000. The sampling size is 304. Results: Among the subjects, 90 (29.6 %) had air-conditioner at home and the rest did not. X2-test and multiple logistic regression analyses showed that, the difference between the exposure and control groups was statistically significant in semen volume, sperm density and proportion of sperm with normal morphology. The three indexes were lower in the exposure group. Conclusion: Air-conditioner exposure possibly influences the semen quality. 展开更多
关键词 semen quality air-conditionER influencing factors
下载PDF
KOF(Z)DI8II and KQF(Z)D24II automobile air-conditioner
7
《China's Foreign Trade》 1999年第7期38-38,共1页
TheYueyangHengliRefrigeratingEquipmentCo.Ltd.inHunanProvinceobtainedin1997itsIS09001certificationfromChinaandGermanYTheKQF(Z)D2411automobileair-conditioneriscomposedoftWoparts,itscoldvolumeis24KWandcanbeusedforpasseng... TheYueyangHengliRefrigeratingEquipmentCo.Ltd.inHunanProvinceobtainedin1997itsIS09001certificationfromChinaandGermanYTheKQF(Z)D2411automobileair-conditioneriscomposedoftWoparts,itscoldvolumeis24KWandcanbeusedforpassengercarswith5to60seats.Theproductsi... 展开更多
关键词 II Z)DI8II and KQF DI Z)D24II automobile air-conditioner KOF
下载PDF
Deploying a Deep Learning-based Application for an Efficient Ther­mal Energy Storage Air-Conditioning(TES-AC)System:Design Guidelines
8
作者 Mirza Rayana Sanzana Mostafa Osama Mostafa Abdulrazic +1 位作者 Jing Ying Wong Chun-Chieh Yip 《Journal of Electronic & Information Systems》 2022年第2期21-29,共9页
Facility management and maintenance of the Thermal-Energy-Storage Air-Conditioning(TES-AC)system is a tedious task at a large scale mainly due to the charging load that can increase energy consumption if needed to be ... Facility management and maintenance of the Thermal-Energy-Storage Air-Conditioning(TES-AC)system is a tedious task at a large scale mainly due to the charging load that can increase energy consumption if needed to be charged at peak hours.Besides,maintenance of TES-AC at a large scale gets complex as it contains many sensor data.By utilizing deep learning techniques on the sensor data,charging load prediction can be made possible,so facility managers can prepare in advance.However,a deep learning-based application will be unusable if it is not deployed in a user-friendly manner where facility managers can benefit from this application.Hence,this research focuses on gathering design guidelines for a deep learning-based application and further validates the design considerations with a developed application for efficient human-computer interaction through qualitative analysis.The approach taken to gather design guidelines demonstrated a positive correlation between expert-suggested features and the user-friendly aspect of the application as 67.08%of participants found the features suggested by experts to be most satisfactory.Furthermore,it evaluates user satisfaction with the advanced developed application for TES-AC according to the gathered design guidelines. 展开更多
关键词 Advanced application Deep learning Thermal-energy-storage air-conditionER Facility management and maintenance Analysis Design guidelines
下载PDF
Mathematical Model of Electric Vehicle Power Consumption for Traveling and Air-Conditioning
9
作者 Seishiro Shibata Tsuguhiko Nakagawa 《Journal of Energy and Power Engineering》 2015年第3期269-275,共7页
In order to make maximum use of the EV (electric vehicle) battery, evaluating the remaining battery capacity and the power consumption is important. Evaluation method of the remaining battery capacity with accuracy ... In order to make maximum use of the EV (electric vehicle) battery, evaluating the remaining battery capacity and the power consumption is important. Evaluation method of the remaining battery capacity with accuracy has been proposed. Moreover, the evaluation method of the power consumption for traveling has been proposed. However, the power consumption for vehicle-mounted air-conditioner is 30%. It is necessary to calculate the power consumption for both traveling and air-conditioning. In this paper, the authors have constructed a mathematical model which calculates the EV power consumption for both traveling and air-conditioning. The calculated results of this model have been compared to actual traveling data. In addition, factors which have a impact on the EV power consumption have been studied. As a result, the EV power consumption is greately varied by slope resistance, acceleration resistance and required air-conditioning load. Moreover, it is clarified that the air-conditioner consumes approximately 25% to 50% of the total power consumption in a hot summer day. In addition, the acceleration and the air-conditioning load differ depending on each vehicle driver. Therefore, in order to evaluate the EV power consumption practically, it is necessary to reflect the characteristics of each vehicle driver. 展开更多
关键词 Electric vehicle air-conditionER energy consumption mathematical model cruising range.
下载PDF
Design of ionic liquids as liquid desiccant for an air conditioning system 被引量:3
10
作者 Haruki Watanabe Takuro Komura +4 位作者 Ryo Matsumoto Kenta Ito Hiroshi Nakayama Toshiki Nokami Toshiyuki Itoh 《Green Energy & Environment》 SCIE CSCD 2019年第2期139-145,共7页
Suitable control of the humidity can contribute to electric energy savings. However, the present dehumidification system has many weak points. The liquid desiccant air-conditioning system has recently gained growing i... Suitable control of the humidity can contribute to electric energy savings. However, the present dehumidification system has many weak points. The liquid desiccant air-conditioning system has recently gained growing interest from the stand point of reducing energy consumption during dehumidification. In order to find the appropriate ionic liquids(ILs) as a desiccant for the liquid desiccant air-conditioner system, we conducted a systematic evaluation of the humidification capability of 16 types of ILs. Among the tested ILs, tributyl(methyl)phosphonium dimethyl phosphate([P4441][DMPO_4]) exhibited the best dehumidification capacity and had a less corrosive effect on four types of metals as possible piping materials. It should be noted that this [P_(4441)][DMPO_4] has a very stable nature and produced no odor while conducting the experiment and storing for over 1 year at room temperature under ambient conditions. Furthermore, it was revealed that a 77%(w/w) aqueous solution of [P4441][DMPO_4] worked as an efficient desiccant liquid for the liquid desiccant air-conditioner system. 展开更多
关键词 DEHUMIDIFICATION Liquid DESICCANT Ionic liquids air-conditionER system PHOSPHONIUM ILS
下载PDF
Experimental Study of the Controlling Characteristics of Inverter-Driven Multi-type Air Conditioner
11
作者 金纪峰 陈江平 陈芝久 《Journal of Shanghai Jiaotong university(Science)》 EI 2004年第4期52-56,共5页
The controlling algorithm was studied for the inverter-driven multi-type air conditioner using electronic expansion valve(EEV) in outdoor unit. The performance of inverter-driven air conditioner with two different uni... The controlling algorithm was studied for the inverter-driven multi-type air conditioner using electronic expansion valve(EEV) in outdoor unit. The performance of inverter-driven air conditioner with two different units was investigated by varying the outdoor ambient temperature and compressor speed. Based on the test results, the effect of EEV opening on the indoor unit exit superheat was discussed. For the specified outdoor ambient temperature scope and the EEV opening, the superheats of indoor units decrease with the outdoor ambient temperature rising. Improper distribution of refrigerant into each indoor unit will causes excessive superheat difference between two indoor units. Suggestions were then given for the controlling of the superheat. 展开更多
关键词 electronic expansion valve (EEV) INVERTER COMPRESSOR air-conditionER
下载PDF
Using Condensed Water of Air Conditioners for Toilet Flushing: A Case Study in Brazil
12
作者 Celso Silva Bastos Joao Luiz Calmon 《Journal of Civil Engineering and Architecture》 2013年第1期98-104,共7页
Within the concept of sustainable construction, with sensible and conscious use of finite natural resources, every effort to save and reuse raw-materials is considered an important step to be adopted in buildings, fro... Within the concept of sustainable construction, with sensible and conscious use of finite natural resources, every effort to save and reuse raw-materials is considered an important step to be adopted in buildings, from project, implantation and construction to operation and maintenance throughout their lifecycle. This study aims at showing the application of a system that reuses condensed water drained from air-conditioner evaporators (which are usually disposed of), and a plan to use this water for toilet flushing, reducing consumption of treated water bought from water companies. The authors verified that each air-conditioner specified in the project of a commercial building--used as reference here--produces 4.8 L of water per hour of operation. This result in a daily accumulated volume of 4,290 L, which represents a significant part of the amount needed to supply all the toilets in the building. A water capture system located at a strategic intermediate floor would be able to store this water and pump it into a special reservoir on the roof of the building, to be distributed into toilet flush pipes. By applying this technology, the authors seek to considerably reduce the expected treated water consumption and consequently decrease water bill costs. 展开更多
关键词 Water reuse air-conditionER toilet flush.
下载PDF
Design of Control Scheme for Variable Air Volume Air- conditioning System
13
作者 Zhang Fan 《International Journal of Technology Management》 2014年第9期152-156,共5页
The air quantity of variable air volume system for the rooms and the total air quantity of the system changes with the change of room load. Combined with the system composition in the laboratory, the paper determines ... The air quantity of variable air volume system for the rooms and the total air quantity of the system changes with the change of room load. Combined with the system composition in the laboratory, the paper determines the control scheme of the variable air volume system, that is, indoor temperature-control, indoor positive pressure control, air distribution static pressure control, air-supply temperature control and new air volume control. The dotted lines with arrows mean the output signals from the control unit to actuator, and the solid lines with arrows represent the input signals from the actuator to the control unit. 展开更多
关键词 variable air volume air-conditionER control scheme
下载PDF
Thermodynamic Analysis and Experimental Research of Water-Cooled Small Space Thermoelectric Air-Conditioner 被引量:3
14
作者 JIANG Fan MENG Fankai +1 位作者 CHEN Lin’gen CHEN Zhaojun 《Journal of Thermal Science》 SCIE EI CAS CSCD 2022年第2期390-406,共17页
This paper aims to find a more general analysis method for the refrigeration performance,and to design a high efficiency modular cooling structure of water-cooled plate.A new analysis method,namely current and refrige... This paper aims to find a more general analysis method for the refrigeration performance,and to design a high efficiency modular cooling structure of water-cooled plate.A new analysis method,namely current and refrigeration rate density analysis,is proposed.The general refrigeration performance calculation equations are obtained.A finite-time thermodynamic model of the thermoelectric device is established considering Thomson effect.The basic structure of water-cooled thermoelectric air-conditioner is designed and the specific calculation method is given.The influences of input current density,filling factor and heat transfer conditions on refrigeration performance of the thermoelectric air-conditioner are analyzed,which is compared with refrigeration performance of air-cooled thermoelectric air-conditioner.The results show that the maximum refrigeration rate density of the water-cooled thermoelectric air-conditioner is 8.65 k W/m^(2),and the maximum coefficient of performance(COP)is 2.27 in the case of the cooling temperature differenceΔT=5 K.Compared withΔT=5 K,the maximum refrigeration rate density and the maximum COP ofΔT=15 K decreases by 27.98%and 76.65%,respectively.At the filling factorθ=0.43,the refrigeration rate density and COP are 2.57 k W/m~2 and 1.24,respectively.The experimental device of thermoelectric air-conditioner is established to verify the model.The experimental results show that the maximum value of input current and COP is 4 A and 0.95 with the efficient water-cooling method,respectively.The experimental data coincides with the theoretical calculation,which shows the validity of the analysis method and cooling method. 展开更多
关键词 thermoelectric air-conditioner refrigeration rate density COP finite-time thermodynamics non-equilibrium thermodynamics performance optimization
原文传递
Technologies and Practical Implementations of Air-conditioner Based Demand Response 被引量:1
15
作者 Muhammad Waseem Zhenzhi Lin +3 位作者 Yi Ding Fushuan Wen Shengyuan Liu Ivo Palu 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第6期1395-1413,共19页
Nowadays,the most notable uncertainty for an electricity utility lies in the electrical demand of end-users.Demand response(DR)has acquired considerable attention due to uncertain generation outputs from intermittent ... Nowadays,the most notable uncertainty for an electricity utility lies in the electrical demand of end-users.Demand response(DR)has acquired considerable attention due to uncertain generation outputs from intermittent renewable energy sources and advancements of smart grid technologies.The percentage of the air-conditioner(AC)load over the total load demand in a building is usually very high.Therefore,controlling the power demand of ACs is one of significant measures for implementing DR.In this paper,the increasing development of ACs,and their impacts on power demand are firstly introduced,with an overview of possible DR programs.Then,a comprehensive review and discussion on control techniques and DR programs for ACs to manage electricity utilization in residential and commercial energy sectors are carried out.Next,comparative analysis among various programs and projects utilized in different countries for optimizing electricity consumption by ACs is presented.Finally,the conclusions along with future recommendations and challenges for optimal employment of ACs are presented in the perspective of power systems. 展开更多
关键词 air-conditioner(AC) commercial load cooling demand demand response(DR) energy consumption residential load
原文传递
Design of quaternary ammonium type-ionic liquids as desiccants for an air-conditioning system
16
作者 Sho Maekawa Ryo Matsumoto +4 位作者 Kenta Ito Toshiki Nokami Jian-Xin Li Hiroshi Nakayama Toshiyuki Itoh 《Green Chemical Engineering》 2020年第2期109-116,共8页
The liquid desiccant air-conditioning system allows reducing energy consumption compared to the conventional compressor-type air conditioners.In order to develop desiccant materials for air conditioners,we have invest... The liquid desiccant air-conditioning system allows reducing energy consumption compared to the conventional compressor-type air conditioners.In order to develop desiccant materials for air conditioners,we have investigated the dehumidification capability of quaternary ammonium Ionic Liquids(ILs)and the equilibrium water vapor pressure of aqueous solutions of these ammonium salts.Among the seven tested types of ILs,2-hydroxyN,N,N-trimethylethan-1-aminium dimethylphosphate([Ch][DMPO4])displayed the best dehumidification capability and the lowest equilibrium water vapor pressure.Furthermore,the 80%aqueous solution of[Ch][DMPO4]exhibited a less corrosive effect on four types of metals,i.e.,steel(hot dip zinc-aluminum alloy plated steel),copper(C1100P),aluminum(A5052),and stainless steel(SUS:SUS304).It should be noted that this[Ch][DMPO4]is not only non-toxic but also exhibits a stable nature;the aqueous solution produced no odor after storing for over 1 year under ambient conditions. 展开更多
关键词 DEHUMIDIFICATION Liquid desiccant Choline type ionic liquid air-conditioner system
原文传递
Analysis of indoor set-point temperature of split-type ACs on thermal comfort and energy savings for office buildings in hot-humid climates 被引量:1
17
作者 KofiOwura Amoabeng Richard Opoku +1 位作者 Samuel Boahen George Yaw Obeng 《Energy and Built Environment》 2023年第3期368-376,共9页
In hot-humid climates,particularly in sub-Saharan Africa(SSA),ambient temperatures and relative humidity are as high as 35°C and 84%,respectively,requiring the use of mechanical cooling systems for indoor thermal... In hot-humid climates,particularly in sub-Saharan Africa(SSA),ambient temperatures and relative humidity are as high as 35°C and 84%,respectively,requiring the use of mechanical cooling systems for indoor thermal comfort.Split-type vapor-compression air-conditioners(SVAC)are mainly used for space cooling in SSA and consume 60-80%of total energy consumption in commercial and public buildings.Appropriate control strategy of the indoor set-point temperature of SVAC can result in significant energy savings in these buildings.In this study,modeling and dynamic simulation have been conducted using EnergyPlus to predict the energy saving potential and indoor thermal comfort of buildings in hot-humid climates by controlling set-point temperature of the SVAC.In a case study,climatic data for Ghana,was used to predict the energy saving potential and indoor thermal comfort.The study results revealed that,to ensure indoor thermal comfort at high outdoor temperature condition of 35°C,the least and optimum set-point temperatures of the SVAC should be 21°C and 25°C,respectively.On the other hand,for low outdoor temperature condition,the least and optimum set-point temperatures were 22°C and 26°C,respectively.Considering 1-star and 2-star rated SVACs which are dominantly used in Ghana,operating at 21-25°C in the case of high outdoor conditions,and 22-26°C for low outdoor conditions relative to the least temperatures resulted in energy savings of 8-33%and 12-44%,respectively. 展开更多
关键词 Hot-humid climate air-conditioners Indoor thermal comfort Set-point temperatures Energy savings
原文传递
Indoor environment of nearly zero energy residential buildings with conventional air conditioning in hot-summer and cold-winter zone
18
作者 Jiankai Dong Haixia Lan +2 位作者 Yu Liu Xiaotao Wang Chenchen Yu 《Energy and Built Environment》 2022年第2期129-138,共10页
According to the few researches on Nearly zero energy residential buildings(NZERB)in hot-summer and cold-winter zone,although it could reduce the cooling load of buildings due to its high thermal insulation and air ti... According to the few researches on Nearly zero energy residential buildings(NZERB)in hot-summer and cold-winter zone,although it could reduce the cooling load of buildings due to its high thermal insulation and air tightness,it still needed for certain cooling in summer.This paper studied indoor environment of NZERB un-der three kinds of air-conditioners(split-type air-conditioner,multi-line air-conditioner and ceiling radiant air-conditioner).Firstly,a simulation model of NZERB was established based on Nanjing,a typical city in hot-summer and cold-winter zone.Secondly,variation of indoor air temperature and building load characteristics with outdoor air temperature were studied.Thirdly,indoor environment and energy consumption under three selected con-ventional air-conditioners in summer were simulated.Finally,the discussion was given,and an air-conditioner combining with convective and radiant cooling were proposed.The results indicated that the air-conditioner needed to be turned on in NZERB in hot-summer and cold-winter zone due to the room air temperature in off-air condition ranged from 32℃to 36℃,which was higher than designed indoor environment temperature in sum-mer,but the indoor environment of NZERB under three selected conventional air-conditioners could not meet the requirements of energy saving and comfort at the same time,and a proposed convective-radiant air-conditioner could be fast,stable,and energy saving.The findings can provide a reference for conducting active technology in NZERB. 展开更多
关键词 Nearly zero energy residential building Load characteristics air-conditioners Indoor environment Hot-summer and cold-winter zone
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部