Under the condition of steady state, the pressure drop of coolant is mainly caused by friction along the cable. In the CICC (cable-in-conduit-conductor), helium flow within the conductor consists of two parallel inter...Under the condition of steady state, the pressure drop of coolant is mainly caused by friction along the cable. In the CICC (cable-in-conduit-conductor), helium flow within the conductor consists of two parallel interconnected tubes. The velocity distribution has some differece between the central channel and conductor space. The region of Reynolds number is from 103 to 106. This paper describes the calculation of pressure drop of HT-7U CICC at various mass flows. It is assumed that the coolant flows in two parallel, rough tubes during the calculation.展开更多
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipat...A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures.展开更多
The nonlinear dispersion relations and modified relations proposed by Kirby and Hedges have the limitation of intermediate minimum value. To overcome the shortcoming, a new nonlinear dispersion relation is proposed. B...The nonlinear dispersion relations and modified relations proposed by Kirby and Hedges have the limitation of intermediate minimum value. To overcome the shortcoming, a new nonlinear dispersion relation is proposed. Based on the summarization and comparison of existing nonlinear dispersion relations, it can be found that the new nonlinear dispersion relation not only keeps the advantages of other nonlinear dispersion relations, but also significantly reduces the relative errors of the nonlinear dispersion relations for a range of the relative water depth of 1<kh<1.5 and has sufficient accuracy for practical purposes.展开更多
The purpose of this paper is to find some better methods for calculating in-line forces on a vertical circular cylinder and for analysing the hydrodynamic coefficients C_D and C_M in wave-current co-existing field. In...The purpose of this paper is to find some better methods for calculating in-line forces on a vertical circular cylinder and for analysing the hydrodynamic coefficients C_D and C_M in wave-current co-existing field. In this pa- per, in order to calculate hydrodynamic forces, the authors try to find a way of applying a great number of the re- sults about C_D and C_M for wave-only field in the case of wave-current co-existing field, and the results about C_D and C_M obtained in regular waves in the ease of irregular waves. Such a way may be of significance in engineering and further research.展开更多
基金This work was supported by the National Meg-science Engineering Project of the Chinese Government.
文摘Under the condition of steady state, the pressure drop of coolant is mainly caused by friction along the cable. In the CICC (cable-in-conduit-conductor), helium flow within the conductor consists of two parallel interconnected tubes. The velocity distribution has some differece between the central channel and conductor space. The region of Reynolds number is from 103 to 106. This paper describes the calculation of pressure drop of HT-7U CICC at various mass flows. It is assumed that the coolant flows in two parallel, rough tubes during the calculation.
基金National Natural Science Foundation of China under Grant No.51148009National Natural Science Foundation of China under Grant No.50978005Project High-level Personnel in Beijing under Grant No.PHR20100502
文摘A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures.
基金This work was financially supported by the Key Project of National Natural Science Foundation of China (Grant No.50339010) and the Key Project of Chinese Ministry of Education (Grant No.03095)
文摘The nonlinear dispersion relations and modified relations proposed by Kirby and Hedges have the limitation of intermediate minimum value. To overcome the shortcoming, a new nonlinear dispersion relation is proposed. Based on the summarization and comparison of existing nonlinear dispersion relations, it can be found that the new nonlinear dispersion relation not only keeps the advantages of other nonlinear dispersion relations, but also significantly reduces the relative errors of the nonlinear dispersion relations for a range of the relative water depth of 1<kh<1.5 and has sufficient accuracy for practical purposes.
文摘The purpose of this paper is to find some better methods for calculating in-line forces on a vertical circular cylinder and for analysing the hydrodynamic coefficients C_D and C_M in wave-current co-existing field. In this pa- per, in order to calculate hydrodynamic forces, the authors try to find a way of applying a great number of the re- sults about C_D and C_M for wave-only field in the case of wave-current co-existing field, and the results about C_D and C_M obtained in regular waves in the ease of irregular waves. Such a way may be of significance in engineering and further research.