Perturbation method of boundary geometry(PMOBG) used in Lapiacian problems is dealt with and the three--term perturbation expression of distributed capacitance of a coaxial line with perturbed walls is obtained. As an...Perturbation method of boundary geometry(PMOBG) used in Lapiacian problems is dealt with and the three--term perturbation expression of distributed capacitance of a coaxial line with perturbed walls is obtained. As an example,four-order expression of distributed capacitance of a elliptic coaxial line with small eccentricity is given.展开更多
A new waveguide to coaxial line transition adopted to microwave band is proposed in this paper.The configuration and design of the transition is studied. It has the merits of simplicity in structure, ease ofconstructi...A new waveguide to coaxial line transition adopted to microwave band is proposed in this paper.The configuration and design of the transition is studied. It has the merits of simplicity in structure, ease ofconstruction and repeatable performance, especially that the coaxial line is in the same direction with thewaveguide. At X band, the pass bandwidth of the transition is about 6%, and the insertion loss less than 1dB.展开更多
AIM:To compare visual quality after femtosecond laser in situ keratomileusis(FS-LASIK),between the coaxially sighted corneal light reflex(CSCLR) group and conventional ablation line of sight(LOS) group.METHODS...AIM:To compare visual quality after femtosecond laser in situ keratomileusis(FS-LASIK),between the coaxially sighted corneal light reflex(CSCLR) group and conventional ablation line of sight(LOS) group.METHODS:In total,243 eyes(122 patients) were treated with centration on the CSCLR(visual axis) and 238 eyes(119 patients) treated with centration on the pupil center(LOS).Postoperative outcomes [uncorrected visual acuity(UCVA),best spectacle-corrected visual acuity(BSCVA)],safety index,efficacy index,refractive outcome,ablation center distance from the visual axis,corneal high-order aberrations,subjective discomfort glare and shadowing incidence rate,and contrast sensitivity at 1,3,and 6mo were measured and compared.RESULTS:The mean age was 27.77±7.1y in the CSCLR group and 26.03±7.70 y in the LOS group.Preoperatively,the manifest refraction spherical equivalent(MRSE) was-6.68±2.60 D in the CSCLR group and-6.65±2.68 D in the LOS group.The postoperative UCVA,BSCVA,MRSE(-0.03±0.263 D in the CSCLR group,-0.05±0.265 D in the LOS group),efficacy index(1.04,1.03),and safety index(1.09,1.08) were not significantly different between the groups(all P〉0.05).In total,3% lost one line and more of BSCVA in the CSCLR group,as 9% in the LOS group postoperatively(P〈0.05).The ablation center deviation was 0.20±0.15 mm from the visual axis(Pentacam system default setting;range,0-0.75 mm) in the CSCLR group,and 0.43±0.22 mm(range,0-1.32 mm) in the LOS group(P〈0.0001).Statistically significant greater augmentationof total corneal higher-order aberrations(0.15±0.10 μm and 0.20±0.12 μm respectively,P=0.03) and vertical and horizontal coma(P〈0.0001) were noted in the LOS group.Subjective discomfort glare and shadowing incidence rates were 8.59% and 17.5% in the CSCLR and LOS groups,respectively(P〈0.05).The 1-month postoperative contrast sensitivity visual acuity in the CSCLR group was significantly higher than that in the LOS group on contrast(100%,25%,10%) with a dark background,but there was no significant difference between the groups at 3 or 6m.CONCLUSION:Myopic LASIK centered on the CSCLR achieves significantly lower induction of loss of BSCVA,corneal high-order aberrations,and lower risk of subjective discomfort glare and shadowing,and lower decline in early contrast sensitivity by comparison with centration on the LOS,giving advantages in visual quality postoperatively.展开更多
An all-metal slow-wave structure, coaxial-radial line, which is suitable for application in broadband high power traveling wave tube (TWT) and relativistic TWT as a RF system is introduced. Making use of the field mat...An all-metal slow-wave structure, coaxial-radial line, which is suitable for application in broadband high power traveling wave tube (TWT) and relativistic TWT as a RF system is introduced. Making use of the field matching method and variational method together with the orthogonality of the Bessel function and the Floquet Theroem for the periodic system, the dispersion characteristic expression is derived. This equation is more rigorous than that of precious reports.展开更多
The partial charge-simulation method is presented for calculating the capacitances of rectangularshielded lines with offset inner conductors.The capacitances calculated by using this method are in goodagreement with t...The partial charge-simulation method is presented for calculating the capacitances of rectangularshielded lines with offset inner conductors.The capacitances calculated by using this method are in goodagreement with those of other available methods.This method can improve the accuracy by increasing theterm number N of series.展开更多
基金the Open Foundation of State Key Laboratory of Advanced Technology for Materials Synthersis Processing
文摘Perturbation method of boundary geometry(PMOBG) used in Lapiacian problems is dealt with and the three--term perturbation expression of distributed capacitance of a coaxial line with perturbed walls is obtained. As an example,four-order expression of distributed capacitance of a elliptic coaxial line with small eccentricity is given.
文摘A new waveguide to coaxial line transition adopted to microwave band is proposed in this paper.The configuration and design of the transition is studied. It has the merits of simplicity in structure, ease ofconstruction and repeatable performance, especially that the coaxial line is in the same direction with thewaveguide. At X band, the pass bandwidth of the transition is about 6%, and the insertion loss less than 1dB.
基金Supported by the Natural Science Foundation of Shanghai Municipal Commission of Health and Family Planning(No.20134230)
文摘AIM:To compare visual quality after femtosecond laser in situ keratomileusis(FS-LASIK),between the coaxially sighted corneal light reflex(CSCLR) group and conventional ablation line of sight(LOS) group.METHODS:In total,243 eyes(122 patients) were treated with centration on the CSCLR(visual axis) and 238 eyes(119 patients) treated with centration on the pupil center(LOS).Postoperative outcomes [uncorrected visual acuity(UCVA),best spectacle-corrected visual acuity(BSCVA)],safety index,efficacy index,refractive outcome,ablation center distance from the visual axis,corneal high-order aberrations,subjective discomfort glare and shadowing incidence rate,and contrast sensitivity at 1,3,and 6mo were measured and compared.RESULTS:The mean age was 27.77±7.1y in the CSCLR group and 26.03±7.70 y in the LOS group.Preoperatively,the manifest refraction spherical equivalent(MRSE) was-6.68±2.60 D in the CSCLR group and-6.65±2.68 D in the LOS group.The postoperative UCVA,BSCVA,MRSE(-0.03±0.263 D in the CSCLR group,-0.05±0.265 D in the LOS group),efficacy index(1.04,1.03),and safety index(1.09,1.08) were not significantly different between the groups(all P〉0.05).In total,3% lost one line and more of BSCVA in the CSCLR group,as 9% in the LOS group postoperatively(P〈0.05).The ablation center deviation was 0.20±0.15 mm from the visual axis(Pentacam system default setting;range,0-0.75 mm) in the CSCLR group,and 0.43±0.22 mm(range,0-1.32 mm) in the LOS group(P〈0.0001).Statistically significant greater augmentationof total corneal higher-order aberrations(0.15±0.10 μm and 0.20±0.12 μm respectively,P=0.03) and vertical and horizontal coma(P〈0.0001) were noted in the LOS group.Subjective discomfort glare and shadowing incidence rates were 8.59% and 17.5% in the CSCLR and LOS groups,respectively(P〈0.05).The 1-month postoperative contrast sensitivity visual acuity in the CSCLR group was significantly higher than that in the LOS group on contrast(100%,25%,10%) with a dark background,but there was no significant difference between the groups at 3 or 6m.CONCLUSION:Myopic LASIK centered on the CSCLR achieves significantly lower induction of loss of BSCVA,corneal high-order aberrations,and lower risk of subjective discomfort glare and shadowing,and lower decline in early contrast sensitivity by comparison with centration on the LOS,giving advantages in visual quality postoperatively.
基金Supported by the Fund of National Key Laboratory (No.51440020101DZ7604)
文摘An all-metal slow-wave structure, coaxial-radial line, which is suitable for application in broadband high power traveling wave tube (TWT) and relativistic TWT as a RF system is introduced. Making use of the field matching method and variational method together with the orthogonality of the Bessel function and the Floquet Theroem for the periodic system, the dispersion characteristic expression is derived. This equation is more rigorous than that of precious reports.
文摘The partial charge-simulation method is presented for calculating the capacitances of rectangularshielded lines with offset inner conductors.The capacitances calculated by using this method are in goodagreement with those of other available methods.This method can improve the accuracy by increasing theterm number N of series.