期刊文献+
共找到1,866篇文章
< 1 2 94 >
每页显示 20 50 100
Slip Compensation in Efficiency-Optimized Three-Phase Induction Motor Drive Systems 被引量:1
1
作者 Hussein Sarhan Rateb Issa +1 位作者 Mohammad Alia Jamal M. Assbeihat 《Intelligent Control and Automation》 2011年第2期95-99,共5页
Energy efficiency optimization techniques of electrical drive systems improve the overall efficiency and reduce the hardness of mechanical characteristics of the drive system. It is therefore important to reduce the s... Energy efficiency optimization techniques of electrical drive systems improve the overall efficiency and reduce the hardness of mechanical characteristics of the drive system. It is therefore important to reduce the slip of induction motor to maintain its stable operation at different frequencies and loads. In this paper a slip compensator, based on fuzzy logic incremental controller has been developed to improve the steady state performance of efficiency-optimized three-phase induction motor drive system. The slip control is accomplished through a fuzzy controller with 9 rules, taking speed error and speed error variation as inputs, to produce the frequency. The proposed controller reduces the slip occurring at low frequencies and light loads to certain value, and also reduces the energy efficiency of the system. 展开更多
关键词 induction MOTOR Efficiency Optimization SLIP compensation Fuzzy LOGIC CONTROLLER
下载PDF
Adaptive current compensation with nonlinear disturbance observer for single-sided linear induction motor considering dynamic eddy-effect
2
作者 邓江明 陈特放 陈春阳 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第5期1716-1724,共9页
An adaptive current compensation control for a single-sided linear induction motor(SLIM) with nonlinear disturbance observer was developed. First, to maintain t-axis secondary component flux constant with consideratio... An adaptive current compensation control for a single-sided linear induction motor(SLIM) with nonlinear disturbance observer was developed. First, to maintain t-axis secondary component flux constant with consideration of the specially dynamic eddy-effect(DEE) of the SLIM, a instantaneously tracing compensation of m-axis current component was analyzed. Second,adaptive current compensation based on Taylor-discretization algorithm was proposed. Third, an effective kind of nonlinear disturbance observer(NDOB) was employed to estimate and compensate the undesired load vibrations, then the robustness of the control system could be guaranteed. Experimental verification of the feasibility of the proposed method for an SLIM control system was performed, and it showed that the proposed adaptive compensation scheme with NDOB could significantly promote speed dynamical response and minimize speed ripple under the conditions of external load coupled vibrations and unavoidable feedback control variables measured errors, i.e., current and speed. 展开更多
关键词 single-sided linear induction motors(SLIMs) current compensation adaptive control dynamical response nonlinear disturbance observer(NDOB)
下载PDF
Simulation Study on Series Capacitor Compensation to Improve the Voltage Quality of Rural Power Distribution Network 被引量:1
3
作者 Hongqiang Li Feng Gao +3 位作者 Xutao Li Shaogui Ai Shuang Zhang Bei Tian 《World Journal of Engineering and Technology》 2015年第3期184-190,共7页
In order to improve the voltage quality of rural power distribution network, the series capacitor in distribution lines is proposed. The principle of series capacitor compensation technology to improve the quality of ... In order to improve the voltage quality of rural power distribution network, the series capacitor in distribution lines is proposed. The principle of series capacitor compensation technology to improve the quality of rural power distribution lines voltage is analyzed. The real rural power distribution network simulation model is established by Power System Power System Analysis Software Package (PSASP). Simulation analysis the effect of series capacitor compensation technology to improve the voltage quality of rural power distribution network, The simulation results show that the series capacitor compensation can effectively improve the voltage quality and reduce network losses and improve the transmission capacity of rural power distribution network. 展开更多
关键词 Series capacitor compensation RURAL Power Distribution Network The Quality of VOLTAGE PSASP Simulation
下载PDF
Switching of Capacitors in an Asymmetric Induction Motor with Single-Phase Power,Triggering Several Applied Loads
4
作者 Prado Wellington Marcos Antonio Geraldo Caixeta Guimarães 《Journal of Energy and Power Engineering》 2020年第3期90-99,共10页
xThis study has as its objective to collaborate with the expansion in the market of electric energy in rural areas,offering as such an innovative prospect to the solution of associated problems through use of the asym... xThis study has as its objective to collaborate with the expansion in the market of electric energy in rural areas,offering as such an innovative prospect to the solution of associated problems through use of the asymmetric three-phase induction motor,supplied by a single-phase source.In this system,capacitor switching is applied during operation,while theoretical and practical results are presented for the application of this switching in a three-phase asymmetric induction motor of 20 hp. 展开更多
关键词 Startup current capacitor switching three-phase induction motor asymmetric motor power factor
下载PDF
Direct on Line Starting Induction Motor with Thyristor Switched Capacitor Based Voltage Regulation
5
作者 E.P.da Silveira R.C. Pires A.T.L.de Almeida A.J.J. Rezek 《Journal of Energy and Power Engineering》 2010年第9期49-55,共7页
The purpose of this paper is to show a laboratory scale implementation of a Thyristor Switched Capacitors (TSC) as an alternative for voltage regulation during a direct on line three-phase induction motor starting o... The purpose of this paper is to show a laboratory scale implementation of a Thyristor Switched Capacitors (TSC) as an alternative for voltage regulation during a direct on line three-phase induction motor starting on an emulated weak transmission line. Thyristor switched capacitor bank was chosen because it is a well known topology, considering the very nature of the direct starting induction motors, which represents a highly inductive load, the use of switched reactors becomes unnecessary. Such fact minimizes the introduction of harmonics components, and also reduces the cost of the implementation. The binary disposition of the banks allows a variable Var compensation with sixteen steps, in this case. The solution makes use of low cost devices combined with sliding window voltage and current measurement algorithm and a PI control with dead band control for achieve the shown experimental results, where the system is able to manage a typically 20% voltage drop, reducing it to less than 4%. The schematic of the developed circuit, the control technique and a quite simple method to calculate the binary weight capacitors banks are also presented. 展开更多
关键词 induction motor thyristor switched capacitor voltage regulation
下载PDF
Comparative study of effectiveness of different var compensation devices in large-scale power networks 被引量:3
6
作者 Reza Sirjani Azah Mohamed Hussain Shareef 《Journal of Central South University》 SCIE EI CAS 2013年第3期715-723,共9页
A comparison of the effectiveness of installing reactive power compensators,such as shunt capacitors,static var compensators(SVCs),and static synchronous compensators(STATCOMs),was presented in large-scale power netwo... A comparison of the effectiveness of installing reactive power compensators,such as shunt capacitors,static var compensators(SVCs),and static synchronous compensators(STATCOMs),was presented in large-scale power networks.A suitable bus was first identified using modal analysis method.The single shunt capacitor,single SVC,and single STATCOM were installed separately on the most critical bus.The effects of the installation of different devices on power loss reduction,voltage profile improvement,and voltage stability margin enhancement were examined and compared for 57-and 118-bus transmission systems.The comparative study results show that SVC,and STATCOM are expensive compared to shunt capacitor,yet the effect of installing STATCOM is better than SVC and the effect of installing SVC is better than that of shunt capacitor in achieving power loss reduction,voltage profile improvement and voltage stability margin enhancement. 展开更多
关键词 shunt capacitor static var compensator static synchronous compensator power loss voltage profile voltage stability
下载PDF
Energy Efficient Control of Three-Phase Induction Motor Drive
7
作者 Hussein Sarhan 《Energy and Power Engineering》 2011年第2期107-112,共6页
Induction motors are extensively used in industrial and household appliances and consume more than 50% of the total generated electrical energy. The need for energy conservation is increasing the requirements for savi... Induction motors are extensively used in industrial and household appliances and consume more than 50% of the total generated electrical energy. The need for energy conservation is increasing the requirements for saving the electrical energy. It is therefore important to optimize the efficiency of electrical drive systems under certain operating conditions. This paper proposes a new control scheme based on search method taking advantage of the fact, that at a certain torque and speed (operating point) there is only one value of stator voltage that operates the motor at optimum efficiency. Simulation performed and results are presented. 展开更多
关键词 induction MOTOR DRIVE Efficiency Optimization SLIP compensation
下载PDF
Microcontroller Control of Reactive Power Compensation for Growing Industrial Loads
8
作者 Edwin N. Mbinkar Derek Ajesam Asoh Sulayman Kujabi 《Energy and Power Engineering》 CAS 2022年第9期460-476,共17页
Many industrial installations in developing countries start-up as small factories, without regard for the need of compensation of reactive power, leading to significant financial losses in the long term. By improving ... Many industrial installations in developing countries start-up as small factories, without regard for the need of compensation of reactive power, leading to significant financial losses in the long term. By improving the power factor, the customer can reduce its power demand and potentially increase efficiency of their equipment. A PIC microcontroller is used to switch capacitor banks to compensate for the reactive power. In order to determine the size of the capacitor bank needed, the microcontroller calculates the phase difference between the voltage and the current. The results obtained based on the lagging power factor for three test loads show an improvement in the power factor from 0.52 to 0.96 under different test load conditions. 展开更多
关键词 Power Factor compensation capacitor Bank PIC Microcontroller Reactive Power
下载PDF
Compensation of Dead-Time Effect of Speed Sensorless Vector Control System
9
作者 夏超英 张靖 《Transactions of Tianjin University》 EI CAS 2011年第5期351-355,共5页
The key of speed sensorless vector control system lies in the accurate orientation of magnetic field. In some field-oriented algorithms, the integrator of observers and the dead-time effect bring in system errors duri... The key of speed sensorless vector control system lies in the accurate orientation of magnetic field. In some field-oriented algorithms, the integrator of observers and the dead-time effect bring in system errors during the estimation of field position. In this paper, a saturated feedback integrator is used, and the dead-time effect is compen- sated by current positive feedback. Experiments were carried out on the hardware platform of MCK2407, with chip TMS320LF2407 from TI Company. The results show that the prooosed method is simole and effective, and the accuracy of field position is improved. 展开更多
关键词 induction motor speed sensorless vector control DSP compensation DEAD-TIME field orientation
下载PDF
A new method to reduce end effect of linear induction motor
10
作者 Xiaozhou GUO Bin ZHOU Jisan LIAN 《Journal of Modern Transportation》 2012年第2期88-92,共5页
A new method to compensate the end effect of a linear induction motor (LIM) in low-speed maglev vehicles is proposed. With this method, the motors are close to each other so that the front motor's exit-end magnetic... A new method to compensate the end effect of a linear induction motor (LIM) in low-speed maglev vehicles is proposed. With this method, the motors are close to each other so that the front motor's exit-end magnetic field extends into the next motor's entry zone. As a result, the motor's magnetic field traveling wave become continuous and the end effect of short primary LIMs is greatly weakened. In the analysis of the air-gap magnetic field distribution, the LIM is assumedly divided into two identical motors vcith the distances of 20, 40, 60, and gO ram. The results show that the air-gap magnetic field is still continuous within these distances due to LIM's end effect. As the distance between two motors increases, the distortion of the air-gap magnetic field becomes more severe. Then, we investigate the relationship between the secondary speed and the thrust in three cases, i.e., a single LIM, two motors divided with 72 mm with pole pitch corrected, and two motors divided with 60 mm without the pole pitch being corrected. We find that the thrust has a small decrease when the speed increases, which means that the magnetic field is already continuous and its amplitude is approximately a constant. Furthermore, the thrust loss of case 3 is more than that of case 2, which indicates that the pole pitch correction is effective. 展开更多
关键词 linear induction motor end effect compensation THRUST pole pitch correction
下载PDF
Performance Study of a Self-Excitation Dual Stator Winding Induction Generator for Renewable Distributed Generation Systems
11
作者 Faris Hamoud Mamadou Lamine Doumbia Ahmed Cheriti 《Smart Grid and Renewable Energy》 2016年第6期197-215,共20页
Renewable power generation is a suitable technology used to deliver energy locally to customers especially in remote regions. Wind energy based on induction generator situates in a foreground position in the total ene... Renewable power generation is a suitable technology used to deliver energy locally to customers especially in remote regions. Wind energy based on induction generator situates in a foreground position in the total energy produced using renewable sources. In the last few decades, a new self- excitation generator was based on multi-stator induction strongly emerges. This article presents a systematic modelling, a detailed analysis and the performance analysis of self-excitation dual stator winding induction generator (SE-DSWIG). The modelling of the SE-DSWIG was done with taking in account the common mutual leakage inductance between stators and the magnetizing inductance, which played a principal role in the stabilization of the output voltage in the steady state. The generator feeds the end user emulated by an inductive-resistive load. In order to simulate the weather conditions’ variation, a step change of the prime mover speed was applied on the SE-DSWIG. A passive series and shunt compensator was used to mitigate the voltage sag and swell appeared in the power system due to wind variation and the lack of reactive power consumed by the inductive load. 展开更多
关键词 Magnetizing inductance Magnetizing Current Voltage Mitigation SELF-EXCITATION Passive compensator
下载PDF
CMOS low-dropout regulator with 3.3 μA quiescent current without off-chip capacitor
12
作者 王忆 崔传荣 +1 位作者 巩文超 何乐年 《Journal of Southeast University(English Edition)》 EI CAS 2009年第1期13-17,共5页
A CMOS (complementary metal-oxide-semiconductor transistor) low-dropout regulator (LDO) with 3. 3 V output voltage and 100 mA output current for system-on-chip applications to reduce board space and external pins ... A CMOS (complementary metal-oxide-semiconductor transistor) low-dropout regulator (LDO) with 3. 3 V output voltage and 100 mA output current for system-on-chip applications to reduce board space and external pins is presented. By utilizing a dynamic slew-rate enhancement(SRE) circuit and nested Miller compensation (NMC) on the LDO structure, the proposed LDO provides high stability during line and load regulation without off-chip load capacitors. The overshot voltage is limited within 550 mV and the settling time is less than 50 μs when the load current decreases from 100 mA to 1 mA. By using a 30 nA reference current, the quiescent current is 3.3 μA. The proposed design is implemented by CSMC 0. 5 μm mixed-signal process. The experimental results agree with the simulation results. 展开更多
关键词 low-dropout regulator off-chip capacitor slew-rate enhancement circuit nested Miller compensation(NMC)
下载PDF
Connections Between Induction Generator Effect and Open-loop Modal Proximity to Cause Sub-synchronous Oscillations in Series-compensated Power System
13
作者 Wenjuan Du Yang Wang +2 位作者 H.F.Wang Tao Zhao Tim Littler 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第3期963-973,共11页
The induction generator effect(IGE)and the openloop modal proximity(OLMP)are two different reasons why subsynchronous oscillations(SSOs)in a series-compensated power system(SCPS)may occur.The IGE attributes the growin... The induction generator effect(IGE)and the openloop modal proximity(OLMP)are two different reasons why subsynchronous oscillations(SSOs)in a series-compensated power system(SCPS)may occur.The IGE attributes the growing SSOs to negative resistance,while the OLMP explains the SSO mechanism from the standpoint of modal conditions.In this paper,we investigate the connections between the IGE and the OLMP through equivalent RLC circuit and open-loop modal analysis.Our investigation is conducted for two types of seriescompensated power systems where either a synchronous generator or a DFIG is connected at the sending end.The investigation reveals the conditions,in which the IGE and the OLMP may jointly cause the growing SSOs,i.e.,both the IGE and the OLMP can explain why the growing SSOs occur.Furthermore,the investigation indicates that the IGE and the OLMP may be totally irrelevant and lead to growing SSOs separately.This implies that it is possible that in a SCPS,the growing SSOs are only due to the IGE,and the OLMP is non-existent,and vice versa.Hence,when the growing SSOs occurs in a SCPS,examination based on both the IGE and the OLMP should be carefully conducted in order to find if the oscillatory instability is due to the IGE,or the OLMP,or both of them. 展开更多
关键词 induction generator effect open-loop modal proximity series compensation sub-synchronous oscillations
原文传递
Research on the Sub-synchronous Oscillation in Wind Power Connected to Series Compensated Power System and its Influencing Factors 被引量:3
14
作者 Chao Gao Hui Liu +2 位作者 Hao Jiang Yunhong Li Xisheng Tang 《CES Transactions on Electrical Machines and Systems》 2017年第3期334-340,共7页
When wind farms,which is based on double fed induction generator(DFIG),are connected to the series compensation power system,the phenomenon of sub-synchronous oscillation(SSO)may occur.In order to study the sub-synchr... When wind farms,which is based on double fed induction generator(DFIG),are connected to the series compensation power system,the phenomenon of sub-synchronous oscillation(SSO)may occur.In order to study the sub-synchronous oscillation in wind power connected to series compensated power system and its influencing factors,we used RT-LAB to establish a simulation model concerning wind power connected to series-compensation power system.This model take a wind power connected to series compensation power system in north China as prototype.All influence factors of wind power SSO are simulated and analyzed by using time domain analysis method.The simulation results show that the effects of wind speed,series compensation degree and proportional control coefficient of rotor side converter(RSC)are most obvious. 展开更多
关键词 Double fed induction generator influence factors interaction of SSO sub-synchronous oscillation series compensation
下载PDF
Optimal Sizing of Capacitor Bank for Increasing Substation Capacity of Mamou
15
作者 Jean Ouèrè Toupouvogui Mohamed Ansoumane Camara +1 位作者 Ansoumane Sakouvogui Mamby Keita 《World Journal of Engineering and Technology》 2023年第2期217-233,共17页
In order to increase the available power of the electrical energy distribution station and improve the voltage profile of the distribution lines, the use of shunt capacitor banks is indicated. The main results obtaine... In order to increase the available power of the electrical energy distribution station and improve the voltage profile of the distribution lines, the use of shunt capacitor banks is indicated. The main results obtained during this study are: a reduction in subscribed power from 14913.978 kVA to 14010.100 kVA, a reduction in the transformer load rate from 99.4% to 93.4%, a reduction in reactive power called from 5481.729 kVAr to 481.729 kVAr, an increase in the active power transported by the substation from 8505.062 kW to 8962.323 kW, a reduction in the voltage drop from 4.8% to 3.9%, an increase in the power available at the secondary of the transformer station at full load from 13950 kW to 14700 kW and an annual electrical energy saving of 339943.48 kWh of electrical energy, therefore fuel savings and a reduction in CO<sub>2</sub> and SO<sub>2</sub> emissions due to this energy saving will be achieved. The installation of capacitor banks for optimization of reactive energy allowed a reduction in the current called therefore a reduction in the absorbed power: 14153.061 kVA, i.e. a reduction of 903.876 kVA. It is therefore essential that energy players are convinced of the need to install capacitors to reduce or even eliminate their reactive energy bill. This is necessarily accompanied by an investment by Electricité De Guinée by setting up active and reactive energy meters but also by implementing pricing in line with the reduction in the transfer of reactive energy in the network. 展开更多
关键词 compensation POWER REACTIVE OPTIMAL BATTERY capacitors
下载PDF
Fault Locator Using Two-end Unsynchronized Measurements for UHV Series Compensated Double-circuit Lines
16
作者 M. Fulczyk P. Balcerek +2 位作者 J. Izykowski E. Rosolowski M. M. Saha 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2523-2529,共7页
An accurate fault location algorithm for double-circuit series compensated lines is presented.Use of two-end unsynchronized measurements of current and voltage signals is considered.The algorithm applies two subroutin... An accurate fault location algorithm for double-circuit series compensated lines is presented.Use of two-end unsynchronized measurements of current and voltage signals is considered.The algorithm applies two subroutines,designated for locating faults on particular line sections,and additionally the procedure for selecting the valid subroutine.The subroutines are formulated with use of the generalized fault loop model and the distributed parameter line model is applied.Performed ATP-EMTP based evaluation has shown the validity of the derived fault location algorithm and its high accuracy. 展开更多
关键词 两端非同步测量法 串联补偿 线路故障 定位仪 ATP-EMTP
下载PDF
A High-Performance Operational Amplifier for High-Speed High-Accuracy Switch-Capacitor Cells
17
作者 Qi Fan Ning Ning Qi Yu Da Chen 《Journal of Electronic Science and Technology of China》 2007年第4期366-369,共4页
A high-speed high-accuracy fully differenttial operational amplifier (op-amp) is realized based on no-Miller-capacitor feedforward (NMCF) compensation scheme. In order to achieve a good phase margin, the NMCF comp... A high-speed high-accuracy fully differenttial operational amplifier (op-amp) is realized based on no-Miller-capacitor feedforward (NMCF) compensation scheme. In order to achieve a good phase margin, the NMCF compensation scheme uses the positive phase shift of left-half-plane (LHP) zero caused by the feedforvvard path to counteract the negative phase shift of the non-dominant pole. Compared to traditional Miller compensation method, the op-amp obtains high gain and wide band synchronously without the pole-splitting effect while saves significant chip area due to the absence of the Miller capacitor. Simulated by the 0.35 μm CMOS RF technology, the result shows that the open-loop gain of the op-amp is 118 dB with the unity gain-bandwidth (UGBW) of 1 GHz, and the phase margin is 61°while the settling time is 5.8 ns when achieving 0.01% accuracy. The op-amp is especially suitable for the front-end sample/hold (S/H) cell and the multiplying D/A converter (MDAC) module of the high-speed high-resolution pipelined A/D converters (AVCs). 展开更多
关键词 Feedforward compensation op-amp pipelined A/D converter switch-capacitor.
下载PDF
采用改进MPC提高储能系统电压暂态特性研究 被引量:1
18
作者 鲍建 杨沛豪 《电源学报》 CSCD 北大核心 2024年第2期242-249,共8页
储能系统通过换流器实现并网运行,常规换流器因为其开关频率低,在采样、计算环节存在延时导致储能系统暂态特性差,甚至引起整个电网不稳定。本文采用模型预测控制MPC(model predictive control)来实现储能系统功率快速响应,避免延时影... 储能系统通过换流器实现并网运行,常规换流器因为其开关频率低,在采样、计算环节存在延时导致储能系统暂态特性差,甚至引起整个电网不稳定。本文采用模型预测控制MPC(model predictive control)来实现储能系统功率快速响应,避免延时影响。引入功率权重价值函数在有功、无功MPC控制中,计算储能换流器输出电压最优值。针对因为滤波电感参数偏移导致的MPC模型不准确问题,本文采用电感误差补偿控制来提高模型精度。通过Matlab/Simulink仿真和实验来验证本文所提方案可提高储能系统暂态特性,有效消除误差对MPC控制性能的影响。 展开更多
关键词 储能系统 暂态特性 模型预测控制 功率权重价值函数 电感误差电压补偿
下载PDF
一种混合耦合电感和开关电容的高增益变换器
19
作者 马子龙 曹华 《电子器件》 CAS 2024年第2期391-396,共6页
为实现用于可再生能源系统的更高电压增益,传统的升压式结构常与相同模块级联以产生高的升压系数。针对此方案效率低和成本高的问题,提出了一种混合耦合电感和开关电容的高增益DC/DC变换器,可在较低的占空比下具有高电压增益;同时具有... 为实现用于可再生能源系统的更高电压增益,传统的升压式结构常与相同模块级联以产生高的升压系数。针对此方案效率低和成本高的问题,提出了一种混合耦合电感和开关电容的高增益DC/DC变换器,可在较低的占空比下具有高电压增益;同时具有连续的输入电流、高效率以及输入和输出之间的共地特征。详细分析了新拓扑结构的性能,并与其他高增益升压变换器进行了比较分析。最后,实验结果证明了所提变换器的正确性和可行性。 展开更多
关键词 DC/DC变换器 高增益 耦合电感 开关电容
下载PDF
一种SOP端口不平衡时直流侧电压脉动抑制策略
20
作者 张国荣 汤彬 +3 位作者 沈聪 王泰文 徐晨林 夏子鹏 《电测与仪表》 北大核心 2024年第3期95-101,共7页
当柔性多状态开关(SOP)端口电压不平衡时,会引起直流侧电压的波动,给整个系统的稳定性带来很大的影响。根据SOP的数学模型,对波动的原因进行了分析,提出一种基于二阶滑模控制的直流侧电压波动抑制策略;通过引入基于非线性干扰观测器的... 当柔性多状态开关(SOP)端口电压不平衡时,会引起直流侧电压的波动,给整个系统的稳定性带来很大的影响。根据SOP的数学模型,对波动的原因进行了分析,提出一种基于二阶滑模控制的直流侧电压波动抑制策略;通过引入基于非线性干扰观测器的电容补偿器装置,对参考电压电流进行精确地跟踪。考虑多种端口电压不平衡的条件,在MATLAB/Simulink中搭建SOP仿真模型,仿真结果表明,该方法对直流侧电压波动抑制有明显的效果。 展开更多
关键词 柔性多状态开关 端口不平衡 滑模控制 电容器补偿装置
下载PDF
上一页 1 2 94 下一页 到第
使用帮助 返回顶部