期刊文献+
共找到39篇文章
< 1 2 >
每页显示 20 50 100
Noise analysis and measurement of time delay and integration charge coupled device 被引量:4
1
作者 王德江 张涛 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第8期348-353,共6页
Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the comp... Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the complete sources of CCD noise, we study the effects of TDI operation mode on noise, and the relationship between different types of noise and number of the TDI stage. Then we propose a new technique to identify and measure sources of TDI CCD noise employing mathematical statistics theory, where theoretical analysis shows that noise estimated formulation converges well. Finally, we establish a testing platform to carry out experiments, and a standard TDI CCD is calibrated by using the proposed method. The experimental results show that the noise analysis and measurement methods presented in this paper are useful for modeling TDI CCDs. 展开更多
关键词 time delay and integration charge coupled device noise measurement remote sensingapplication
下载PDF
Research on detection of lane based on machine vision 被引量:6
2
作者 李旭 张为公 卞晓东 《Journal of Southeast University(English Edition)》 EI CAS 2004年第2期176-180,共5页
To prevent a vehicle from departing the lane in assistant or automatic steering, real-time vision-based detection of lane is studied. The system architecture, detecting principle and lane model are described. Then the... To prevent a vehicle from departing the lane in assistant or automatic steering, real-time vision-based detection of lane is studied. The system architecture, detecting principle and lane model are described. Then the detecting algorithm of the lane image is discussed in detail. In this algorithm, several proper sub-windows in one image are first selected as the processing regions. To every sub-window, by means of such steps as appropriate pre-processing, edge detection and Hough transform, etc., the lane description features are extracted. Experimental results reveal that this detection method is of good real-time, high recognition reliability and strong robustness, etc., which can provide the decision-making foundation for the following automatic or assistant steering to some extent. 展开更多
关键词 Charge coupled devices Computer vision Decision making Edge detection Hough transforms
下载PDF
The future of wireless capsule endoscopy 被引量:15
3
作者 Paul Swain 《World Journal of Gastroenterology》 SCIE CAS CSCD 2008年第26期4142-4145,共4页
We outline probable and possible developments with wireless capsule endoscopy. It seems likely that capsule endoscopy will become increasingly effective in diagnostic gastrointestinal endoscopy. This will be attractiv... We outline probable and possible developments with wireless capsule endoscopy. It seems likely that capsule endoscopy will become increasingly effective in diagnostic gastrointestinal endoscopy. This will be attractive to patients especially for cancer or varices detection because capsule endoscopy is painless and is likely to have a higher take up rate compared to conventional colonoscopy and gastroscopy. Double imager capsules with increased frame rates have been used to image the esophagus for Barrett's and esophageal varices. The image quality is not bad but needs to be improved if it is to become a realistic substitute for flexible upper and lower gastrointestinal endoscopy. An increase in the frame rate, angle of view, depth of field, image numbers, duration of the procedure and improvements in illumination seem likely. Colonic, esophageal and gastric capsules will improve in quality, eroding the supremacy of flexible endoscopy, and become embedded into screening programs. Therapeutic capsules will emerge with brushing, cytology, fluid aspiration, biopsy and drug delivery capabilities. Electrocautery may also become possible. Diagnostic capsules will integrate physiological measurements with imaging and optical biopsy, and immunologic cancer recognition. Remote control movement will improve with the use of magnets and/or electrostimulation and perhaps electromechanical methods. External wireless commands will influence capsule diagnosis and therapy and will increasingly entail the use of real-time imaging. However, it should be noted that speculations about the future of technology in any detail are almost always wrong. 展开更多
关键词 Wireless CAPSULE ENDOSCOPY Future Complementary oxide silicone Charge coupled device Therapy Screening COLONOSCOPY BIOPSY Cancer ELECTROCAUTERY
下载PDF
Treatment of Wet FGD Wastewater by a Modified Chemical Precipitation Method Using a Solid Powder Reagent 被引量:3
4
作者 Yong Kang Jia Lu Jing Guo 《Transactions of Tianjin University》 EI CAS 2017年第2期110-121,共12页
This research focused on developing a modified chemical precipitation (MCP) method for treating wet flue gas desulfurization (FGD) waste water by adding a solid powder reagent directly. Simulated wet FGD wastewater wa... This research focused on developing a modified chemical precipitation (MCP) method for treating wet flue gas desulfurization (FGD) waste water by adding a solid powder reagent directly. Simulated wet FGD wastewater was treated by MCP method in simulation experiments. Optimization experiments were carried out with the help of response surface methodology (RSM) and central composite design (CCD) to evaluate the effects and the interactions of experimental variables, including reagent dosage, temperature and pH value. The optimal reagent dosage, temperature and pH value were 3018.0 mg/L, 40.5 °C and 5.7, respectively. The RSM was demonstrated as an appropriate approach for the optimization of wet FGD wastewater treatment with the MCP method. A comparative study between the MCP method and the traditional chemical precipitation (TCP) method on raw wet FGD wastewater treatment was conducted. Results indicate that the MCP had less reagent dosage and variety than the TCP method had. Thus, the MCP method had a lower cost. © 2017, Tianjin University and Springer-Verlag Berlin Heidelberg. 展开更多
关键词 Charge coupled devices PH Transmission control protocol Wastewater treatment
下载PDF
An Automatic System of Vehicle Number-Plate Recognition Based on Neural Networks 被引量:2
5
作者 Wei Wu Dept. of Road and Traffic Engineering, Changsha Communications University, 410076, P. R. China Huang Xinhan, Wang Min & Song Yexin Dept. of Control Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, P. R. China 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2001年第2期63-72,共10页
This paper presents an automatic system of vehicle number-plate recognition based on neural networks. In this system, location of number-plate and recognition of characters in number-plate can be automatically complet... This paper presents an automatic system of vehicle number-plate recognition based on neural networks. In this system, location of number-plate and recognition of characters in number-plate can be automatically completed. Pixel colors of Number-plate area are classified using neural network, then color features are extracted by analyzing scanning lines of the cross-section of number-plate. It takes full use of number-plate color features to locate number-plate. Characters in number-plate can be effectively recognized using the neural networks. Experimental results show that the correct rate of number-plate location is close to 100%, and the time of number-plate location is less than 1 second. Moreover, recognition rate of characters is improved due to the known number-plate type. It is also observed that this system is not sensitive to variations of weather, illumination and vehicle speed. In addition, and also the size of number-plate need not to be known in prior. This system is of crucial significance to apply and spread the automatic system of vehicle number-plate recognition. 展开更多
关键词 Cameras Charge coupled devices Feature extraction Neural networks VEHICLES
下载PDF
Surface diffuse discharge mechanism of well-aligned atmospheric pressure microplasma arrays 被引量:1
6
作者 周仁武 周儒森 +6 位作者 庄金星 李江炜 陈茂冬 张先徽 刘东平 Kostya (Ken) Ostrikov 杨思泽 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第4期222-230,共9页
A stable and homogeneous well-aligned air microplasma device for application at atmospheric pressure is designed and its electrical and optical characteristics are investigated. Current-voltage measurements and intens... A stable and homogeneous well-aligned air microplasma device for application at atmospheric pressure is designed and its electrical and optical characteristics are investigated. Current-voltage measurements and intensified charge coupled device (ICCD) images show that the well-aligned air microplasma device is able to generate a large-area and homogeneous discharge at the applied voltages ranging from 12 kV to 14 kV, with a repetition frequency of 5 kHz, which is attributed to the diffusion effect of plasma on dielectric surface. Moreover, this well-aligned microplasma device may result in the uniform and large-area surface modification of heat-sensitive PET polymers without damage, such as optimization in hydrophobicity and biocompatibility. In the biomedical field, the utility of this well-aligned microplasma device is further testified. It proves to be very efficient for the large-area and uniform inactivation of E. coli cells with a density of 103/cm2 on LB agar plate culture medium, and inactivation efficiency can reach up to 99% for 2-min treatment. 展开更多
关键词 surface diffusion intensified charge coupled device surface modification bacterial inactivation
下载PDF
Charge Couple Device-Based Systemfor3-di mensional Real Ti me Positioning on the Assessment of Segmental Range of Motion of Lumbar Spine 被引量:1
7
作者 赵平 陈立君 +3 位作者 管晶 潘丽 丁辉 丁海署 《Chinese Journal of Integrated Traditional and Western Medicine》 2005年第4期272-278,共7页
Objective: To observe the tested results of the segmental range of motion (ROM) of lumbar spine by charge couple device (CCD)-based system for 3-dimensional real-time positioning (CCD system), and to analyze it... Objective: To observe the tested results of the segmental range of motion (ROM) of lumbar spine by charge couple device (CCD)-based system for 3-dimensional real-time positioning (CCD system), and to analyze its clinical significance. Methods: Seven patients with lumbar joint dysfunction and 8 healthy subjects were tested twice by the CCD-based system with an interval of 10 min. Results: The ROM of the patients was obviously lesser than that of the healthy subjects. The measuring data of segmental ROM of lumbar spine by CCD system is correlated significantly to the same data checked later on the same subjects in every direction of the movements. The differences between two checks are usually less than 1 degree. Conclusion: Specially designed CCD based system for 3-dimensional real-time positioning could objectively reflect the segmental ROM of lumbar spine. The system would be of great clinical significance in the assessment of the biomechanical dysfunction of lumbar spine and the effect of the treatment applied. 展开更多
关键词 charge couple device camera lumbar spine RADIOLOGY segmental range of motion
下载PDF
Controllably Coupling Superconducting Charge and Flux Qubits by Using Nanomechanical Resonator 被引量:1
8
作者 郭羊青 姜年权 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第5期9-12,共4页
We propose an effective mechanism to couple superconducting charge and flux qubits by using a quantized nanomechanical resonator. The coupling between the charge and flux qubits can be controlled by the external flux ... We propose an effective mechanism to couple superconducting charge and flux qubits by using a quantized nanomechanical resonator. The coupling between the charge and flux qubits can be controlled by the external flux of the charge qubit. Under the strong coupling limR, an iSWAP gate can be generated by this scheme. The experimental feasibility in our scheme is also presented. 展开更多
关键词 Controllably Coupling Superconducting Charge and Flux Qubits by Using Nanomechanical Resonator
下载PDF
Experimental Investigation of Wave Heights in A Directional Wave Field Through Image Sequences
9
作者 Chung-Ren CHOU Teng-Wei LIN +1 位作者 Ruey-Syan SHIH John Z. YIMa 《China Ocean Engineering》 SCIE EI 2005年第1期37-48,共12页
Measurements of wave heights with image sequences from a Charged Coupled Device(CCD) camera were made. Sinusoidal, as well as unidirectional and directional, waves were used for the experiments. A transfer function wa... Measurements of wave heights with image sequences from a Charged Coupled Device(CCD) camera were made. Sinusoidal, as well as unidirectional and directional, waves were used for the experiments. A transfer function was obtained by calibration of the magnitudes of the gray values of the images against the results of wave gauge measurements for directional waves. With this transfer function, wave heights for regular waves were deduced. It is shown that the average relative errors are smaller than 16% for both unidirectional and directional waves. 展开更多
关键词 charged coupled device remote sensing directional wave transfer function wave height measurements
下载PDF
NUMERICAL SIMULATION FOR DYNAMIC INITIAL SHOCK PARAMETERS OF COUPLING CHARGE ON BOREHOLE WALL UNDER THE ACTION OF HIGH EXPLOSIVES
10
作者 倪芝芳 李玉民 《Journal of Coal Science & Engineering(China)》 1996年第1期51-56,共6页
According to detonation theory and hydrodynamic principle, a physical model has been set up in this paper. Based on the model a methodology for calculating dynamic initial shock parameters such as shock pressure pm sh... According to detonation theory and hydrodynamic principle, a physical model has been set up in this paper. Based on the model a methodology for calculating dynamic initial shock parameters such as shock pressure pm shock wave velosity Dm etc. of coupling charge on borehole wall has ben developed. The shock parameters have been calculated when high explosives works on granite, limestone and marble respectively. The magnitude of every parameter on borehole wall has been obtained from ignited dot to the end of borehole along axial direction. Some important conclusions are also gained. 展开更多
关键词 coupling charge initial shock parameter numerical simulation regular oblique reflection Prandtl-Meyer expansion
下载PDF
THE DISTANCE BETWEEN BOREHOLES OF SMOOTH BLASTING BY WATER COUPLING
11
作者 陈士海 《Journal of Coal Science & Engineering(China)》 1998年第1期11-14,共4页
The stress strength factor, length and opening degree of cracks around boreholes as well as movement regularity Of blockage with the smooth blasting by water coupling are calculated out according to the theories of fr... The stress strength factor, length and opening degree of cracks around boreholes as well as movement regularity Of blockage with the smooth blasting by water coupling are calculated out according to the theories of fracture mechanics and explosion dynamics, and the relation between the pressure in holes and the change of hoIe volume is pointed out, thereby the distance between boreholes is worked out in this paper. For limestone, when uncoupling coefficient is 3,diameter of holes is 100 mm, the hole distance of water coupling smooth blasting is 2. 3 m. The result is consistent with practice. 展开更多
关键词 water coupling charge smooth blasting CRACK the distance between boreholes
下载PDF
128×128 element PtSi infrared CCD image sensor
12
作者 YANG Jiade LIU Jungang +1 位作者 LI Zuojin YANG Yasheng (Chongqing Optoelectrouics Research Institute, Yongchuan 632163, CHN) 《Semiconductor Photonics and Technology》 CAS 1995年第1期43-51,共9页
A new 128×128 element PtSi Schottky barrier infrared image sensor with ITCCD readout structure and PtSi thin film optical cavity detector structure has been fabricated,which has 50μm×50 μm pixels,a fill fa... A new 128×128 element PtSi Schottky barrier infrared image sensor with ITCCD readout structure and PtSi thin film optical cavity detector structure has been fabricated,which has 50μm×50 μm pixels,a fill factor of 40 percent,the nonuniformity of 5% or less and the dynamic range of over or equal to 50 dB.The noise equivalent temperature difference is 0.2 K with f/1.0 optics at 300 K background. In this paper,the principle of operation,design consideration and fabrication technology for the device are described. 展开更多
关键词 Infrared Detector Charge coupled Devices Image Sensor Focal Plane Arrays
下载PDF
Design and implementation of high speed TDI CCD timing-driven circuits
13
作者 李波 徐正平 +2 位作者 李军 黄厚田 王德江 《Journal of Measurement Science and Instrumentation》 CAS 2012年第2期185-190,共6页
The time delay integration charge coupled device(TDI CCD)is the key component in remote sensing systems.The paper analyzes the structure and the working principles of the device according to a customized TDI CCD chip.... The time delay integration charge coupled device(TDI CCD)is the key component in remote sensing systems.The paper analyzes the structure and the working principles of the device according to a customized TDI CCD chip.Employing the special clock resources and large-scale phase locked logic(PLL)in field-programmable gate arrays(FPGA),a timing-driven approach is proposed,using which all timing signals including reset gate,horizontal and vertical timing signals,are implemented in one chip.This not only reduces printed circuit board(PCB)space,but also enhances the portability of the system.By studying and calculating CCD parameters thoroughly,load capacity and power consumption,package,etc,are compared between various candidates chips,and detailed comparison results are also listed in table.Experimental results show that clock generator and driving circuit satisfy the requirements of high speed TDI CCD. 展开更多
关键词 time delay integration charge coupled device(TDI CCD) timing-driven circuit field-programmable gate arrays(FPGA)
下载PDF
The Design & Implementation of Multimedia Sensor Node and the Building of Multimedia Network in Smart Home
14
作者 Chao DENG 《International Journal of Technology Management》 2013年第2期8-10,共3页
With the requirements of multimedia service increasing in people' s life, sensor modules such as microphone, camera are added in the smart home' s sensor network, and the acquisition and processing of a large amount... With the requirements of multimedia service increasing in people' s life, sensor modules such as microphone, camera are added in the smart home' s sensor network, and the acquisition and processing of a large amount of information media such as audio, image and video is becoming a significant characteristics of smart home. The paper focuses on solving the following technical problems: the building of Zigbee multimedia network, the Design and selection of multimedia sensor node. These provide the basic network platform and the core technical support for the building of smart home. 展开更多
关键词 Smart Home Zigbee Network Multimedia Sensor Node Charge coupled Device SCCB Bus
下载PDF
Characteristics of the CsI:Tl Scintillator Crystal for X-Ray Imaging Applications
15
作者 Maria da Conceicao Costa Pereira Tufic Madi Filho +1 位作者 Jose Roberto Berretta Carlos Henrique de Mesquita 《Materials Sciences and Applications》 2018年第2期268-280,共13页
Scintillators are high-density luminescent materials that convert X-rays to visible light. Thallium doped cesium iodide (CsI:Tl) scintillation materials are widely used as converters for X-rays into visible light, wit... Scintillators are high-density luminescent materials that convert X-rays to visible light. Thallium doped cesium iodide (CsI:Tl) scintillation materials are widely used as converters for X-rays into visible light, with very high conversion efficiency of 64.000 optical photons/MeV. CsI:Tl crystals are commercially available, but, the possibility of developing these crystals into different geometric shapes, meeting the need for coupling the photosensor and reducing cost, makes this material very attractive for scientific research. The objective of this work was to study the feasibility of using radiation sensors, scintillators type, developed for use in imaging systems for X-rays. In this paper, the CsI:Tl scintillator crystal with nominal concentration of the 10-3 M was grown by the vertical Bridgman technique. The imaging performance of CsI:Tl scintillator was studied as a function of the design type and thickness, since it interferes with the light scattering and, hence, the detection efficiency plus final image resolution. The result of the diffraction X-ray analysis in the grown crystals was consistent with the pattern of a face-centered cubic (fcc) crystal structure. Slices 25 × 2 × 3 mm3 (length, thickness, height) of the crystal and mini crystals of 1 × 2 × 3 mm3 (length, thickness, height) were used for comparison in the imaging systems for X-rays. With these crystals scintillators, images of undesirable elements, such as metals in food packaging, were obtained. One-dimensional array of photodiodes and the photosensor CCD (Coupled Charge Device) component were used. In order to determine the ideal thickness of the slices of the scintillator crystal CsI:Tl, Monte Carlo method was used. 展开更多
关键词 Crystal Growth Scintillator X-RAY Imaging Systems Photodiodes coupled Charge Device
下载PDF
Calibration and Monte Carlo simulation of a single-photon counting charge-coupled device for single-shot X-ray spectrum measurements 被引量:2
16
作者 闫永宏 魏来 +8 位作者 温贤伦 吴玉迟 赵宗清 张博 朱斌 洪伟 曹磊峰 姚泽恩 谷渝秋 《Chinese Optics Letters》 SCIE EI CAS CSCD 2013年第11期9-12,共4页
A Princeton Instruments PI-LCX 1300 charge-coupled device (CCD) camera used for X-ray spectrum measurements in laser-plasma experiments is calibrated using three radioactive sources and investigated with the Monte C... A Princeton Instruments PI-LCX 1300 charge-coupled device (CCD) camera used for X-ray spectrum measurements in laser-plasma experiments is calibrated using three radioactive sources and investigated with the Monte Carlo code Geant4. The exposure level is controlled to make the CCD work in single photon counting mode. A summation algorithm for obtaining accurate X-ray spectra is developed to reconstruct the X-ray spectra, and the results show that the developed algorithm effectively reduces the low-energy tail caused by split pixel events. The obtained CCD energy response shows good linearity. The detection efficiency curves from both Monte Carlo simulations and the manufacturer agree well with the experimental results. This consistency demonstrates that event losses in charge collection processes are negligible when the developed summation algorithm of sDlit Dixel events is emDloved. 展开更多
关键词 ALGORITHMS Charge coupled devices PIXELS X ray analysis X ray spectrographs X rays
原文传递
Spectral calibration in spectral domain optical coherence tomography 被引量:12
17
作者 王凯 丁志华 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第12期902-904,共3页
A novel spectral calibration method is developed for spectral domain optical coherence tomography system. The method is based on two measurements of interference spectra from two reference mirror positions. It removes... A novel spectral calibration method is developed for spectral domain optical coherence tomography system. The method is based on two measurements of interference spectra from two reference mirror positions. It removes the influence of dispersion mismatch, and hence accurately determines the spectral distribution on the line-scan charge-coupled device (CCD) for sequent precise interpolation. High quality imaging can be realized with this method. Elimination of the degradation effect caused by dispersion mismatch is verified experimentally, and improved two-dimensional (2D) imaging of fresh orange pulp based on the proposed spectral calibration method is demonstrated. 展开更多
关键词 CALIBRATION Charge coupled devices Diagnostic radiography Medical imaging Optical tomography PHOTODEGRADATION Strain measurement TOMOGRAPHY
原文传递
Space optical remote sensor image motion velocity vector computational modeling, error budget and synthesis 被引量:16
18
作者 王家骐 于平 +2 位作者 颜昌翔 任建岳 何斌 《Chinese Optics Letters》 SCIE EI CAS CSCD 2005年第7期414-417,共4页
For space optical remote sensor (SORS) with either film or time delay and integrate charge coupled device (TDI-CCD) imaging, in order to achieve higher resolution it requires more accurate real-time image motion compe... For space optical remote sensor (SORS) with either film or time delay and integrate charge coupled device (TDI-CCD) imaging, in order to achieve higher resolution it requires more accurate real-time image motion compensation. This primarily depends on real-time computation of the image motion velocity vector (IMVV) and error budget and synthesis on related parameters. An effective modeling scheme is introduced and the derivation of IMVV equation, error budget and synthesis by Monte-Carlo method are presented in detail. This total solution was applied to SORS system test on orbit and has been confirmed to be very accurate based on the resolution, transfer function at Nyquist frequency, signal-to-noise ratio and average gray scale of the captured images. 展开更多
关键词 Charge coupled devices Imaging techniques Monte Carlo methods Remote sensing Signal to noise ratio Space optics
原文传递
Measurement of spatial object's exterior attitude based on linear CCD 被引量:6
19
作者 艾莉莉 袁峰 丁振良 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第7期505-509,共5页
It is difficult to realize real-time measurement of exterior attitude by the traditional systems based on the area image sensor which have conflict between speed and accuracy. The subsystem for three-dimensional (3D... It is difficult to realize real-time measurement of exterior attitude by the traditional systems based on the area image sensor which have conflict between speed and accuracy. The subsystem for three-dimensional (3D) coordinate reconstruction of point target (S3DCRPT) which is composed of three one-dimensional (1D) cameras based on linear charge-coupled device (CCD) can determine the distant light spots' spatial position. The attitude angle of the measured object is determined by the spatial solution while the coordinate reconstruction is separately carried on by the S3DCRPT with some point cooperation targets (PCTs) on the measured object. A new optical system is designed to solve the interference problem with one-to-one relationship between the PCTs and the S3DCRPT optical subsystems, which improves the measurement accuracy and saves space. The mathematical model of the attitude measurement is established, and partial and global calibrations are realized for the multi-camera attitude measurement system. The test results show the feasibility of the exterior attitude measurement based on linear CCD. 展开更多
关键词 Cameras Charge coupled devices Computer networks Digital cameras KETONES Mathematical models Optical systems Real time systems RESTORATION Time measurement
原文传递
Particle digital in-line holography with spherical wave recording 被引量:5
20
作者 葛宝臻 吕且妮 张以谟 《Chinese Optics Letters》 SCIE EI CAS CSCD 2003年第9期517-519,共3页
In this paper, we propose a method of digital in-line holography of particle. A diverging spherical beam is used for illumination in recording hologram, the complex amplitude distribution generated by particle field a... In this paper, we propose a method of digital in-line holography of particle. A diverging spherical beam is used for illumination in recording hologram, the complex amplitude distribution generated by particle field at a single plane located in the Presnel diffraction region is recorded by CCD, and a plane beam for reconstructing hologram, then, the magnified image can be obtained by numerical reconstruction in computer. This procedure can be interpreted by Fourier optical theory and the theoretical analysis have been done in detail, the experimental results, the air freshener being subject, are also given. 展开更多
关键词 Charge coupled devices Fourier optics
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部