期刊文献+
共找到1,745篇文章
< 1 2 88 >
每页显示 20 50 100
Progress of the bolometer diagnostic system on EAST
1
作者 Wen WEN Yanmin DUAN +6 位作者 Shanshan PAN Yan CHAO Songtao MAO Jing QIAN Lingyi MENG Panjun TANG Shiyao LIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第9期125-132,共8页
Measurements of the total radiated power and its spatial distribution are crucial for fusion research.On the experimental advanced superconducting tokamak(EAST),both the metal foil resistive bolometer and the absolute... Measurements of the total radiated power and its spatial distribution are crucial for fusion research.On the experimental advanced superconducting tokamak(EAST),both the metal foil resistive bolometer and the absolute extreme ultraviolet(AXUV)photodiodes have been used to quantify the radiated power.This article introduces the latest improvement of the bolometer diagnostic system on EAST.It also details the successful design and installation of new divertor AXUV cameras,which are dedicated to the investigation of divertor physics.The shielding components of the bolometer detector have been refined,and the article provides a detailed exposition of the double shielding structures that have been verified as effective in microwave shielding.Additionally,the changes in the radiated power distribution in the divertor region during the plasma detachment process are measured using the divertor AXUV camera.Finally,the radiated power measured by the AXUV detector and metal foil resistive bolometer are compared,and different detector performances are presented. 展开更多
关键词 radiated power bolometer diagnostic microwave shielding plasma detachment sensitivity degradation
下载PDF
Soft x-ray Diode-array Diagnostic System for HT-7 Superconducting Tokamak 被引量:1
2
作者 胡立群 卫明生 +2 位作者 凌必利 方自深 曾立 《Plasma Science and Technology》 SCIE EI CAS CSCD 2000年第6期515-521,共7页
A diagnostic system of soft x-ray diode-array was set up for HT-7 superconducting tokamak. The system consists of two slot-aperture cameras and is capable of measuring the soft x-ray emission from the plasma on HT-7 d... A diagnostic system of soft x-ray diode-array was set up for HT-7 superconducting tokamak. The system consists of two slot-aperture cameras and is capable of measuring the soft x-ray emission from the plasma on HT-7 device with a high resolution in space and a high response in time. Both cameras, located separately in a horizontal port and a vertical port each with thirty-seven detectors of An-Si surface-barrier diode (SBD) can view the same toroidal cross-section of the plasma from different poloidal chords. In this paper, the structure, principle and performance of the diagnostic system are described and some experimental results observed are presented. 展开更多
关键词 LHCD Soft x-ray Diode-array diagnostic system for HT-7 Superconducting Tokamak HT SBD MODE
下载PDF
Study of Failure Diagnostic Methods and Intelligent Diagnostic System for Reciprocating Compressors 被引量:5
3
作者 LIU Wei hua, ANG Hai song Nanjing University of Aeronautics and Astronautics, Nanjing 210016, P.R.China 《International Journal of Plant Engineering and Management》 2002年第3期126-132,共7页
Three categories of failure diagnostic methods for reciprocating compressors are classified according to the signals adopted by the diagnosis. They are parameter method, vibration method, and oil analysis method. In t... Three categories of failure diagnostic methods for reciprocating compressors are classified according to the signals adopted by the diagnosis. They are parameter method, vibration method, and oil analysis method. In this paper, the applicable range and operational difficulties of these methods are discussed on the basis of analysis and induction upon normal failure. It is proposed that a compressor's normal failure can be divided into thermodynamical property failure and mechanical function failure. As to the former, the parameter method that takes a cylinder pressure signal as the main diagnostic signal may be applied; and as to the latter, the vibration signal frequency spectrum can be used to diagnose. At the same time, the structure of an intelligent diagnostic system based on neural networks is introduced, and its schematic is given. 展开更多
关键词 failure diagnostic method intellingent diagnostic system reciprocating compressor
下载PDF
Intelligent Medical Diagnostic System for Hepatitis B
4
作者 Dalwinder Singh Deepak Prashar +3 位作者 Jimmy Singla Arfat Ahmad Khan Mohammed Al-Sarem Neesrin Ali Kurdi 《Computers, Materials & Continua》 SCIE EI 2022年第12期6047-6068,共22页
The hepatitis B virus is the most deadly virus,which significantly affects the human liver.The termination of the hepatitis B virus is mandatory and can be done by taking precautions as well as a suitable cure in its ... The hepatitis B virus is the most deadly virus,which significantly affects the human liver.The termination of the hepatitis B virus is mandatory and can be done by taking precautions as well as a suitable cure in its introductory stage;otherwise,it will become a severe problem and make a human liver suffer from the most dangerous diseases,such as liver cancer.In this paper,two medical diagnostic systems are developed for the diagnosis of this life-threatening virus.The methodologies used to develop thesemodels are fuzzy logic and the neuro-fuzzy technique.The diverse parameters that assist in the evaluation of performance are also determined by using the observed values from the proposed system for both developedmodels.The classification accuracy of a multilayered fuzzy inference system is 94%.The accuracy with which the developed medical diagnostic system by using Adaptive Network based Fuzzy Interference System(ANFIS)classifies the result corresponding to the given input is 95.55%.The comparison of both developed models on the basis of their performance parameters has been made.It is observed that the neuro-fuzzy technique-based diagnostic system has better accuracy in classifying the infected and non-infected patients as compared to the fuzzy diagnostic system.Furthermore,the performance evaluation concluded that the outcome given by the developed medical diagnostic system by using ANFIS is accurate and correct as compared to the developed fuzzy inference system and also can be used in hospitals for the diagnosis of Hepatitis B disease.In other words,the adaptive neuro-fuzzy inference system has more capability to classify the provided inputs adequately than the fuzzy inference system. 展开更多
关键词 Artificial intelligence fuzzy logic hepatitis B hybrid system medical diagnostic system neural network neuro-fuzzy technique
下载PDF
Development of a Thomson Scattering Diagnostic System on EAST 被引量:3
5
作者 臧庆 赵君煜 +6 位作者 杨利 胡庆生 贾燕庆 张涛 席晓琦 S.H.BHATTI 高翔 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第2期144-148,共5页
A multipulse and multipoint Nd:YAG (neodymium-yttrium aluminum garnet) laser Thomson scattering diagnostic system was developed on EAST to obtain more accurate electron temperature Te and electron density ne profil... A multipulse and multipoint Nd:YAG (neodymium-yttrium aluminum garnet) laser Thomson scattering diagnostic system was developed on EAST to obtain more accurate electron temperature Te and electron density ne profiles. In this paper, the optical system, the VME (versa module eurocard)-based real-time computer system for laser control, data acquisition, analysis and calibration are discussed in detail. Furthermore, a developed data processing method is presented. 展开更多
关键词 multipulse/multipoint Nd:YAG laser Thomson scattering diagnostic EAST tokamak
下载PDF
Development of a fast electron bremsstrahlung diagnostic system based on LYSO and silicon photomultipliers during lower hybrid current drive for tokamak 被引量:1
6
作者 Weiwei FAN Bowen ZHENG +3 位作者 Jing CAO Shibiao TANG Qingwei YANG Zejie YIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第6期88-97,共10页
A novel real time fast electron bremsstrahlung (FEB) diagnostic system based on the lutetium yttrium oxyorthosilicate scintillators (LYSO) and silicon photomultipliers (SiPM) has been developed for tokamak.The diagnos... A novel real time fast electron bremsstrahlung (FEB) diagnostic system based on the lutetium yttrium oxyorthosilicate scintillators (LYSO) and silicon photomultipliers (SiPM) has been developed for tokamak.The diagnostic system is dedicated to study the FEB emission in the hard x-ray (HXR) energy range between 10 and 200 keV during the lower hybrid current drive.The system consists of a detection module and three data acquisition and processing (DAP)boards.The detection module consists of annulus LYSO-SiPM detector array and a 12-channel preamplifier module.The DAP boards upload the data to the host computer for displaying and storing through PXI bus.The time and space resolutions of the system are 10 ms and 4 cm,respectively.The experimental results can show the evolution over time and the spatial distribution of FEB.This paper presents the system performance and typical discharge results. 展开更多
关键词 diagnostic system fast electron BREMSSTRAHLUNG HARD x-ray HL-2A TOKAMAK
下载PDF
Design of Thomson Scattering Diagnostic System on EAST 被引量:1
7
作者 杨利 万宝年 +5 位作者 赵君煜 胡庆生 贾燕庆 席晓琦 韩效锋 臧庆 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第3期284-288,共5页
Primary physical design of the Thomson scattering system for EAST, including the configuration of the system and the design considerations of different sections of the system, is presented. The expected measurability ... Primary physical design of the Thomson scattering system for EAST, including the configuration of the system and the design considerations of different sections of the system, is presented. The expected measurability of this design, namely an electron temperature of 513 eV to 5 keV and a plasma density beyond 0.5× 10^19 m^-3, fulfills the requirements of the EAST operation. 展开更多
关键词 Thomson scattering diagnostic physical design plasma temperature plasma density
下载PDF
Laser Cleaning of Mirror Surface for Optical Diagnostic Systems of the International Thermonuclear Experimental Reactor 被引量:1
8
作者 Aleksandra Alexandrova Buzhinskij Oleg Igorevich +2 位作者 Konstantin Gubskiy Andrey Kuznetsov Vitaly Shtamm 《Journal of Physical Science and Application》 2013年第1期1-8,共8页
The development of cleaning optics and deposition-mitigating techniques is a key factor in the construction and operation of optical diagnostics in ITER. The cleaning of optical surface by pulsed radiation from a fibe... The development of cleaning optics and deposition-mitigating techniques is a key factor in the construction and operation of optical diagnostics in ITER. The cleaning of optical surface by pulsed radiation from a fiber laser is an effective method that can recover optical properties of the mirror surface. The possibility of cleaning metallic mirrors from films with complex composition by pulsed radiation from a fiber laser has been experimentally researched. It has been shown that the high initial reflection characteristics of optical elements can be recovered by choosing regimes of radiation effect on the deposited surface. Efficient cleaning is ensured by radiation with the power density of less than 107 W/cm2. At this relatively low power density, pollutions are removed in a solid phase and the thermal effect on the mirror is insignificant. Preliminary experiments of the metal mirrors cleaning by fiber laser radiation have demonstrated the possibility of hardware implementation techniques. 展开更多
关键词 Carbon impurities COATING optical diagnostics LASER spectroscopy.
下载PDF
Construction of an Hα diagnostic system and its application to determine neutral hydrogen densities on the Keda Torus eXperiment
9
作者 Junfeng Zhu Tao Lan +18 位作者 Ge Zhuang Tijian Deng Jie Wu Hangqi Xu Chen Chen Sen Zhang Jiaren Wu Yiming Zu Hong Li Jinlin Xie Ahdi Liu Zixi Liu Zhengwei Wu Hai Wang Xiaohui Wen Haiyang Zhou Chijin Xiao Weixing Ding Wandong Liu 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第10期428-434,共7页
A 10-channel Hα diagnostic system has been designed with the rapid response rate of 300 kHz, spatial resolution of about 40 mm, and overlap between adjacent channels of about 3%, and it has been implemented successfu... A 10-channel Hα diagnostic system has been designed with the rapid response rate of 300 kHz, spatial resolution of about 40 mm, and overlap between adjacent channels of about 3%, and it has been implemented successfully on Keda Torus eXperiment(KTX), a newly constructed, reversed field pinch(RFP) experimental device at the University of Science and Technology of China(USTC). This diagnostic system is a very important tool for the initial KTX operations. It is compact,with an aperture slit replacing the traditional optical lens system. A flexural interference filter is designed to prevent the center wavelength from shifting too much as the increase of angle from vertical incidence. To eliminate the stray light,the interior of the system is covered with the black aluminum foil having a very high absorptivity. Using the Hαemission data, together with the profiles of electron temperature and density obtained from the Langmuir probe, the neutral density profiles have been calculated for KTX plasmas. The rapid response rate and good spatial resolution of this Hαdiagnostic system will be beneficial for many studies in RFP plasma physics. 展开更多
关键词 diagnostic NEUTRAL density Keda TORUS eXperiment(KTX) device
下载PDF
Implementation of Automatic Process of Edge Rotation Diagnostic System on J-TEXT Tokamak
10
作者 张泽品 程芝峰 +4 位作者 罗剑 王之江 张晓龙 侯赛英 成诚 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第8期789-793,共5页
A spectral diagnostic control system (SDCS) is developed to implement automatic process of the edge rotation diagnostic system on the J-TEXT tokamak. The SDCS contains a control module, data operation module, data a... A spectral diagnostic control system (SDCS) is developed to implement automatic process of the edge rotation diagnostic system on the J-TEXT tokamak. The SDCS contains a control module, data operation module, data analysis module, and data upload module. The core of this system is a newly developed software "Spectra Assist", which completes the whole process by coupling all related subroutines and servers. The results of data correction and calculated rotation are presented. In the daily discharge of J-TEXT, SDCS is proved to have a stable performance and high efficiency in completing the process of data acquisition, operation and results output. 展开更多
关键词 edge rotation diagnostic control system J-TEXT mixed programming
下载PDF
Operational definitions and measurement of externalizing behavior problems:An integrative review including research models and clinical diagnostic systems
11
作者 Lidia Torres-Rosado Oscar M Lozano +2 位作者 Manuel Sanchez-Garcia Fermín Fernández-Calderón Carmen Diaz-Batanero 《World Journal of Psychiatry》 SCIE 2023年第6期278-297,共20页
Measurement of externalizing disorders such as antisocial disorders,attentiondeficit/hyperactivity disorder or borderline disorder have relevant implications for the daily lives of people with these disorders.While th... Measurement of externalizing disorders such as antisocial disorders,attentiondeficit/hyperactivity disorder or borderline disorder have relevant implications for the daily lives of people with these disorders.While the Diagnostic and Statistical Manual of Mental Disorders(DSM)and the International Classification of Diseases(ICD)have provided the diagnostic framework for decades,recent dimensional frameworks question the categorical approach of psychopathology,inherent in traditional nosotaxies.Tests and instruments develop under the DSM or ICD framework preferentially adopt this categorical approach,providing diagnostic labels.In contrast,dimensional measurement instruments provide an individualized profile for the domains that comprise the externalizing spectrum,but are less widely used in practice.Current paper aims to review the operational definitions of externalizing disorders defined under these different frameworks,revise the different measurement alternatives existing,and provide an integrative operational definition.First,an analysis of the operational definition of externalizing disorders among the DSM/ICD diagnostic systems and the recent Hierarchical Taxonomy of Psychopathology(HiTOP)model is carried out.Then,in order to analyze the coverage of operational definitions found,a description of measurement instruments among each conceptualization is provided.Three phases in the development of the ICD and DSM diagnosis systems can be observed with direct implications for measurement.ICD and DSM versions have progressively introduced systematicity,providing more detailed descriptions of diagnostic criteria and categories that ease the measurement instrument development.However,it is questioned whether the DSM/ICD systems adequately modelize externalizing disorders,and therefore their measurement.More recent theoretical approaches,such as the HiTOP model seek to overcome some of the criticism raised towards the classification systems.Nevertheless,several issues concerning this model raise mesasurement challenges.A revision of the instruments underneath each approach shows incomplete coverage of externalizing disorders among the existing instruments.Efforts to bring nosotaxies together with other theoretical models of psychopathology and personality are still needed.The integrative operational definition of externalizing disorders provided may help to gather clinical practice and research. 展开更多
关键词 Externalizing disorders Measurement diagnostic and Statistical Manual of Mental Disorders International Classification of Diseases Hierarchical Taxonomy of Psychopathology PSYCHOPATHOLOGY
下载PDF
Modern Control and Diagnostic System of Traction Vehicle with Hybrid Drive System
12
作者 Zygnunt Szymanski 《Computer Technology and Application》 2016年第4期215-226,共12页
In paper it introduced a review of modem traction vehicle drive system with induction motor drive system (PMSM with single or dual rotor drive system) or BLDC motor with different configuration of magnetic circuits.... In paper it introduced a review of modem traction vehicle drive system with induction motor drive system (PMSM with single or dual rotor drive system) or BLDC motor with different configuration of magnetic circuits. For particular part of drive system proposed a quasi intelligent control system version smart control enables multi criteria predictive control of vehicle work. In the paper presented also a selected diagnostic procedure, enables monitoring exploitation parameters, and prediction of probable failure state. For different vehicle work state realized a simulation models and crash test of exploitations failure models. 展开更多
关键词 Smart control diagnostic model hybrid vehicle.
下载PDF
Diagnostic Accuracy of Computerized Bowel Sound Analysis with Non-Invasive Devices for Irritable Bowel Syndrome:A Systematic Review and Meta-Analysis
13
作者 Xia-Xiao Yan Yue-Lun Zhang +2 位作者 Yu-Pei Zhang Ying-Yun Yang Dong Wu 《Chinese Medical Sciences Journal》 CAS CSCD 2024年第2期122-130,共9页
Objective To assess the diagnostic accuracy of bowel sound analysis for irritable bowel syndrome(IBS)with a systematic review and meta-analysis.Methods We searched MEDLINE,Embase,the Cochrane Library,Web of Science,an... Objective To assess the diagnostic accuracy of bowel sound analysis for irritable bowel syndrome(IBS)with a systematic review and meta-analysis.Methods We searched MEDLINE,Embase,the Cochrane Library,Web of Science,and IEEE Xplore databases until September 2023.Cross-sectional and case-control studies on diagnostic accuracy of bowel sound analysis for IBS were identified.We estimated the pooled sensitivity,specificity,positive likelihood ratio,negative likeli-hood ratio,and diagnostic odds ratio with a 95% confidence interval(CI),and plotted a summary receiver operat-ing characteristic curve and evaluated the area under the curve.Results Four studies were included.The pooled diagnostic sensitivity,specificity,positive likelihood ratio,nega-tive likelihood ratio,and diagnostic odds ratio were 0.94(95%CI,0.87‒0.97),0.89(95%CI,0.81‒0.94),8.43(95%CI,4.81‒14.78),0.07(95%CI,0.03‒0.15),and 118.86(95%CI,44.18‒319.75),respectively,with an area under the curve of 0.97(95%CI,0.95‒0.98).Conclusions Computerized bowel sound analysis is a promising tool for IBS.However,limited high-quality data make the results'validity and applicability questionable.There is a need for more diagnostic test accuracy studies and better wearable devices for monitoring and analysis of IBS. 展开更多
关键词 irritable bowel syndrome bowel sound analysis diagnostic accuracy systematic review META-ANALYSIS
下载PDF
A comprehensive diagnostic system of ultra-thin liquid sheet targets
14
作者 Ziyang Peng Zhengxuan Cao +19 位作者 Xuan Liu Yinren Shou Jiarui Zhao Shiyou Chen Ying Gao Pengjie Wang Zhusong Mei Zhuo Pan Defeng Kong Shirui Xu Zhipeng Liu Yulan Liang Tianqi Xu Tan Song Xun Chen Qingfan Wu Yujia Zhang Zihao Zhang Xueqin Yan Wenjun Ma 《High Power Laser Science and Engineering》 SCIE CAS CSCD 2024年第3期41-50,共10页
To meet the demands of laser-ion acceleration at a high repetition rate,we have developed a comprehensive diagnostic system for real-time and in situ monitoring of liquid sheet targets(LSTs).The spatially resolved rap... To meet the demands of laser-ion acceleration at a high repetition rate,we have developed a comprehensive diagnostic system for real-time and in situ monitoring of liquid sheet targets(LSTs).The spatially resolved rapid characterizations of an LST’s thickness,flatness,tilt angle and position are fulfilled by different subsystems with high accuracy.With the help of the diagnostic system,we reveal the dependence of thickness distribution on collision parameters and report the 238-nm liquid sheet generated by the collision of two liquid jets.Control methods for the flatness and tilt angle of LSTs have also been provided,which are essential for applications of laser-driven ion acceleration and others. 展开更多
关键词 diagnosticS laser-ion acceleration liquid sheet targets
原文传递
Storage time affects the level and diagnostic efficacy of plasma biomarkers for neurodegenerative diseases
15
作者 Lifang Zhao Mingkai Zhang +4 位作者 Qimeng Li Xuemin Wang Jie Lu Ying Han Yanning Cai 《Neural Regeneration Research》 SCIE CAS 2025年第8期2373-2381,共9页
Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is k... Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is known about the long-term stability of these biomarker proteins in plasma samples stored at-80°C.We aimed to explore how storage time would affect the diagnostic accuracy of these biomarkers using a large cohort.Plasma samples from 229 cognitively unimpaired individuals,encompassing healthy controls and those experiencing subjective cognitive decline,as well as 99 patients with cognitive impairment,comprising those with mild cognitive impairment and dementia,were acquired from the Sino Longitudinal Study on Cognitive Decline project.These samples were stored at-80°C for up to 6 years before being used in this study.Our results showed that plasma levels of Aβ42,Aβ40,neurofilament light chain,and glial fibrillary acidic protein were not significantly correlated with sample storage time.However,the level of total tau showed a negative correlation with sample storage time.Notably,in individuals without cognitive impairment,plasma levels of total protein and tau phosphorylated protein threonine 181(p-tau181)also showed a negative correlation with sample storage time.This was not observed in individuals with cognitive impairment.Consequently,we speculate that the diagnostic accuracy of plasma p-tau181 and the p-tau181 to total tau ratio may be influenced by sample storage time.Therefore,caution is advised when using these plasma biomarkers for the identification of neurodegenerative diseases,such as Alzheimer's disease.Furthermore,in cohort studies,it is important to consider the impact of storage time on the overall results. 展开更多
关键词 Alzheimer’s disease amyloid-β diagnostic ability glial fibrillary acidic protein NEURODEGENERATION neurofilament light chain plasma biomarkers single molecule array storage time tau
下载PDF
Advancing healthcare through laboratory on a chip technology:Transforming microorganism identification and diagnostics
16
作者 Carlos M Ardila 《World Journal of Clinical Cases》 SCIE 2025年第3期9-19,共11页
In a recent case report in the World Journal of Clinical Cases,emphasized the crucial role of rapidly and accurately identifying pathogens to optimize patient treatment outcomes.Laboratory-on-a-chip(LOC)technology has... In a recent case report in the World Journal of Clinical Cases,emphasized the crucial role of rapidly and accurately identifying pathogens to optimize patient treatment outcomes.Laboratory-on-a-chip(LOC)technology has emerged as a transformative tool in health care,offering rapid,sensitive,and specific identification of microorganisms.This editorial provides a comprehensive overview of LOC technology,highlighting its principles,advantages,applications,challenges,and future directions.Success studies from the field have demonstrated the practical benefits of LOC devices in clinical diagnostics,epidemiology,and food safety.Comparative studies have underscored the superiority of LOC technology over traditional methods,showcasing improvements in speed,accuracy,and portability.The future integration of LOC with biosensors,artificial intelligence,and data analytics promises further innovation and expansion.This call to action emphasizes the importance of continued research,investment,and adoption to realize the full potential of LOC technology in improving healthcare outcomes worldwide. 展开更多
关键词 Laboratory-on-a-chip Microorganism identification diagnosticS Point-ofcare testing Biosensors
下载PDF
Motor oil condition evaluation based on on-board diagnostic system 被引量:6
17
作者 Lei WEI Haitao DUAN +6 位作者 Dan JIA Yongliang JIN Song CHEN Lian LIU Jianfang LIU Xianming SUN Jian LI 《Friction》 SCIE CSCD 2020年第1期95-106,共12页
The condition of the motor oil in civilian cars is difficult to monitor;hence,we propose a method to evaluate the degree of degradation of motor oil using an on‐board diagnostic(OBD)system.Three civilian cars and fou... The condition of the motor oil in civilian cars is difficult to monitor;hence,we propose a method to evaluate the degree of degradation of motor oil using an on‐board diagnostic(OBD)system.Three civilian cars and four motor oils(containing mineral oils and synthetic oils)were subjected to five groups of road tests under urban traffic and high‐way conditions.The operation information,oil service time,mileage,engine operation time,idle time of the engine,and number of start‐ups of the engine were obtained using the proposed OBD system.Physiochemical properties and changes in the components of motor oils during road tests were analyzed in laboratory.The theoretical model of the comprehensive indicators of driving parameters and oil properties were established.The proposed method was successfully applied to different cars,motor oils,and operating conditions in road tests.All the theoretical models had high accuracy and precision.Herein,we provide a method to monitor the oil condition with real‐time driving parameters and provide a reference for end users to change their motor oil reasonably. 展开更多
关键词 motor oil oil condition evaluation on‐board diagnostic system
原文传递
New RF trip diagnostic system of BEPCII
18
作者 Ziwei Deng Qunyao Wang +2 位作者 Haiyin Lin Pei Zhang Jianping Dai 《Radiation Detection Technology and Methods》 CSCD 2021年第4期594-599,共6页
Background The upgrade project of the Beijing Electron Positron Collider(BEPCII)is a high-current electron–positron collider with beam intensity close to 1A.The RF system plays an important role in providing energy f... Background The upgrade project of the Beijing Electron Positron Collider(BEPCII)is a high-current electron–positron collider with beam intensity close to 1A.The RF system plays an important role in providing energy for the beam,compressing the beam length and maintaining beam lifetime.Once the RF system shuts down the RF power for various reasons,the accelerator will stop working.Purpose In order to determine which reason causes the RF trip,a new RF trip diagnostic system was built based on the NI PXI system.Method The new RF trip diagnostic system is used to collect the data of the forward power,reflected power,cavity voltage,and beam current in a period of time before and after the RF trip event happens.The system uses LabVIEW as the control software,which conducts I/Q sampling of down-converted RF signals directly,then calculates the amplitude and phase of each RF signal,and plots the change curve.The data and figures are stored in the disk and MySQL database.The change curve can be replotted by the data browser which developed by the Python or PHP language.Results Through the analysis of the RF trip data and figures that produced by the new RF trip system,it can be clear whether the RF trip is caused by the RF system,so as to locate the reason of the RF trip more quickly and improve the reliability and stability of the machine operation. 展开更多
关键词 RF system RF trip diagnostic system Data acquisition LABVIEW
原文传递
AN ORIGINAL DIAGNOSTIC SYSTEM FOR MALARIA TO SCREEN THE ANTIPLASMODIAL ACTIVITY OF AFRICAN HERBAL MEDICINES
19
作者 Okusa Philippe N.Traoré Orokia Duez Pierre +3 位作者 Avaert Richard Haddadi Zainab Blankert Bertrand Okusa Philippe 《World Journal of Traditional Chinese Medicine》 2015年第4期79-79,共1页
Malaria,caused by protozoa of the genus Plasmodium,causes some 198 million of confirmed cases and about584,000 of deaths per year.Its management needs both accurate diagnostic and treatments availability.The current d... Malaria,caused by protozoa of the genus Plasmodium,causes some 198 million of confirmed cases and about584,000 of deaths per year.Its management needs both accurate diagnostic and treatments availability.The current diagnostic techniques(rapid diagnostic tests and microscopy)appear either too expensive,lowly sensitive or difficult to implement.The hemozoin('malaria pigment') 展开更多
关键词 AN ORIGINAL diagnostic system FOR MALARIA TO SCREEN THE ANTIPLASMODIAL ACTIVITY OF AFRICAN HERBAL MEDICINES
原文传递
Intestinal pseudo-obstruction in patients with systemic lupus erythematosus: A real diagnostic challenge 被引量:5
20
作者 Carlos Alberto García López Fernando Laredo-Sánchez +2 位作者 José Malagón-Rangel Miguel G Flores-Padilla Haiko Nellen-Hummel 《World Journal of Gastroenterology》 SCIE CAS 2014年第32期11443-11450,共8页
Intestinal pseudo-obstruction secondary to systemic lupus erythematosus(SLE) is a rare syndrome described in recent decades. There are slightly over 30 published cases in the English language literature, primarily ass... Intestinal pseudo-obstruction secondary to systemic lupus erythematosus(SLE) is a rare syndrome described in recent decades. There are slightly over 30 published cases in the English language literature, primarily associated with renal and hematological disease activity. Its presentation and evolution are a diagnostic challenge for the clinician. We present four cases of intestinal pseudo-obstruction due to lupus in young Mexican females. One patient had a previous diagnosis of SLE and all presented with a urinary tract infection of varying degrees of severity during their evolution. We consider that recognition of the disease is of vital importance because it allows for establishing appropriate management, leading to a better prognosis and avoiding unnecessary surgery and complications. 展开更多
关键词 Intestinal pseudo-obstruction systemic lupus erythematosus Uretero-hydronephrosis Urinary tract infection diagnostic challenge
下载PDF
上一页 1 2 88 下一页 到第
使用帮助 返回顶部