In this paper,the network reliability of an actual digital instrument and control system (DICS) network is analyzed by using GO-FLOW methodology (GFM).The evaluations of common-cause failure (CCF) and uncertainty are ...In this paper,the network reliability of an actual digital instrument and control system (DICS) network is analyzed by using GO-FLOW methodology (GFM).The evaluations of common-cause failure (CCF) and uncertainty are incorporated.Three significant CCF groups (real time servers,gateways,reactor protection system) and three typical time intervals (10 min,1 h,and 24 h) are selected in the analysis.It is concluded that the network contribution of CCF accounts for over 68% of the system failure probability.The result indicates that GFM is suitable for the network reliability analysis.展开更多
Threshold decision is an important function of nuclear instrument control system based on physical parameters threshold decision. Because the conventional decision methods lack correlation with time and conditions, by...Threshold decision is an important function of nuclear instrument control system based on physical parameters threshold decision. Because the conventional decision methods lack correlation with time and conditions, by analyzing the existing methods, some optimized methods are adopted. Considering safety, those methods are improved in data processing algorithms, floating threshold with multiple values, association with specific working condition, etc. These measures im- prove the nuclear instrument control system in fault tolerance and fault diagnosis, especially, the shutdown number of nucle- ar power plant decreases.展开更多
The design principle and structural features of a new type dual-channel ground-based microwave radiometer for measurement of water vapor and liquid water in troposphere are discussed. A method independent of radiosond...The design principle and structural features of a new type dual-channel ground-based microwave radiometer for measurement of water vapor and liquid water in troposphere are discussed. A method independent of radiosonde data is used for system absolute calibrations. A statistical method for retrieving the total water vapor and cloud liquid water content and a nonlinear iterative algorithm for retrieving the water vapor profiles in the troposphere are discussed. Comparison is conducted between the measurement of the integrated amounts of the water vapor and the tropospheric vapor profiles by the radiometer and the radiosonde data.展开更多
A computer aided design system for developing musical fountain programs was developed with multiple functions such as intelligent design, 3-D animation, manual modification and synchronized motion to make the develop...A computer aided design system for developing musical fountain programs was developed with multiple functions such as intelligent design, 3-D animation, manual modification and synchronized motion to make the development process more efficient. The system first analyzed the music form and sentiment using many basic features of the music to select a basic fountain program. Then, this program is simulated with 3-D animation and modified manually to achieve the desired results. Finally, the program is transformed to a computer control program to control the musical fountain in time with the music. A prototype system for the musical fountain was also developed. It was tested with many styles of music and users were quite satisfied with its performance. By integrating various functions, the proposed computer aided design system for developing musical fountain programs greatly simplified the design of the musical fountain programs.展开更多
基金Supported by Nuclear Safety Research Association and Tohoku University for Nuclear Researchers Exchange Program 2010National High Technology and Development Program ("863"Program)of China(No.2007AA041009)
文摘In this paper,the network reliability of an actual digital instrument and control system (DICS) network is analyzed by using GO-FLOW methodology (GFM).The evaluations of common-cause failure (CCF) and uncertainty are incorporated.Three significant CCF groups (real time servers,gateways,reactor protection system) and three typical time intervals (10 min,1 h,and 24 h) are selected in the analysis.It is concluded that the network contribution of CCF accounts for over 68% of the system failure probability.The result indicates that GFM is suitable for the network reliability analysis.
基金Research Project of Hunan Province Education Department(No.14C0972)
文摘Threshold decision is an important function of nuclear instrument control system based on physical parameters threshold decision. Because the conventional decision methods lack correlation with time and conditions, by analyzing the existing methods, some optimized methods are adopted. Considering safety, those methods are improved in data processing algorithms, floating threshold with multiple values, association with specific working condition, etc. These measures im- prove the nuclear instrument control system in fault tolerance and fault diagnosis, especially, the shutdown number of nucle- ar power plant decreases.
文摘The design principle and structural features of a new type dual-channel ground-based microwave radiometer for measurement of water vapor and liquid water in troposphere are discussed. A method independent of radiosonde data is used for system absolute calibrations. A statistical method for retrieving the total water vapor and cloud liquid water content and a nonlinear iterative algorithm for retrieving the water vapor profiles in the troposphere are discussed. Comparison is conducted between the measurement of the integrated amounts of the water vapor and the tropospheric vapor profiles by the radiometer and the radiosonde data.
基金Supported by the National Natural Science Foundationof China(No.6 0 174 0 15 ) and the Basic Research Foun-dation of Tsinghua U niversity
文摘A computer aided design system for developing musical fountain programs was developed with multiple functions such as intelligent design, 3-D animation, manual modification and synchronized motion to make the development process more efficient. The system first analyzed the music form and sentiment using many basic features of the music to select a basic fountain program. Then, this program is simulated with 3-D animation and modified manually to achieve the desired results. Finally, the program is transformed to a computer control program to control the musical fountain in time with the music. A prototype system for the musical fountain was also developed. It was tested with many styles of music and users were quite satisfied with its performance. By integrating various functions, the proposed computer aided design system for developing musical fountain programs greatly simplified the design of the musical fountain programs.