期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Research on Slot-pole Combination in High-power Direct-drive PM Vernier Generator for Fractional Frequency Transmission System 被引量:3
1
作者 Zhidong Yuan Shaofeng Jia +2 位作者 Deliang Liang Xiuli Wang Yong Yang 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第4期445-453,共9页
Offshore wind energy is an important part of clean energy,and the adoption of wind energy to generate electricity will contribute to the implementation of the carbon peaking and carbon neutrality goals.The combination... Offshore wind energy is an important part of clean energy,and the adoption of wind energy to generate electricity will contribute to the implementation of the carbon peaking and carbon neutrality goals.The combination of the fractional frequency transmission system(FFTS) and the direct-drive wind turbine generator will be beneficial to the development of the offshore wind power industry.The use of fractional frequency in FFTS is beneficial to the transmission of electrical energy,but it will also lead to an increase in the volume and weight of the generator,which is unfavorable for wind power generation.Improving the torque density of the generator can effectively reduce the volume of the generators.The vernier permanent magnet machine(VPM) operates on the magnetic flux modulation principle and has the merits of high torque density.In the field of electric machines,the vernier machine based on the principle of magnetic flux modulation has been proved its feasibility to reduce the volume and weight.However,in the field of low-speed direct-drive machines for high-power fractional frequency power generation,there are still few related researches.Therefore,this paper studies the application of magnetic flux modulation in fractional frequency and high-power direct-drive wind turbine generators,mainly analyzes the influence of different pole ratios and different pole pairs on the generator,and draws some conclusions to provide reference for the design of wind turbine generators. 展开更多
关键词 direct-drive wind turbine generators Fractional frequency transmission system Pole ratio The magnetic flux modulation Vernier machine
下载PDF
Overview of condition monitoring and operation control of electric power conversion systems in direct-drive wind turbines under faults 被引量:1
2
作者 Shoudao HUANG Xuan WU +2 位作者 Xiao LIU Jian GAO Yunze HE 《Frontiers of Mechanical Engineering》 SCIE CSCD 2017年第3期281-302,共22页
Electric power conversion system (EPCS), which consists of a generator and power converter, is one of the most important subsystems in a direct-drive wind turbine (DD-WT). However, this component accounts for the ... Electric power conversion system (EPCS), which consists of a generator and power converter, is one of the most important subsystems in a direct-drive wind turbine (DD-WT). However, this component accounts for the most failures (approximately 60% of the total number) in the entire DD-WT system according to statistical data. To improve the reliability of EPCSs and reduce the operation and maintenance cost of DD-WTs, numerous researchers have studied condition monitoring (CM) and fault diagnostics (FD). Numerous CM and FD techniques, which have respective advantages and disadvantages, have emerged. This paper provides an overview of the CM, FD, and operation control of EPCSs in DD-WTs under faults. After introducing the functional principle and structure of EPCS, this survey discusses the common failures in wind generators and power converters; briefly reviewed CM and FD methods and operation control of these generators and power converters under faults; and discussed the grid voltage faults related to EPCSs in DD-WTs. These theories and their related technical concepts are systematically discussed. Finally, predicted development trends are presented. The paper provides a valuable reference for developing service quality evaluation methods and fault operation control systems to achieve high-performance and high-intelligence DD-WTs. 展开更多
关键词 direct-drive wind turbine electric power conversion system condition monitoring fault diagnosis operation control under faults fault tolerance
原文传递
电网故障下含直驱风电机组的电力系统频率动态响应分析
3
作者 欧阳金鑫 余建峰 +2 位作者 张澳归 皇甫百香 姚骏 《电力系统自动化》 EI CSCD 北大核心 2024年第8期111-121,共11页
电网受扰后基于模型解析的频率响应分析对电力系统安全评估与紧急控制具有重要意义。电网发生故障时,直驱风电机组(DDWT)并网点电压幅值跌落引发控制器暂态响应,同时电压相位突变引发锁相暂态响应,锁相暂态响应又通过变流器控制传导产... 电网受扰后基于模型解析的频率响应分析对电力系统安全评估与紧急控制具有重要意义。电网发生故障时,直驱风电机组(DDWT)并网点电压幅值跌落引发控制器暂态响应,同时电压相位突变引发锁相暂态响应,锁相暂态响应又通过变流器控制传导产生功率控制误差,可能导致现有以负荷突变场景为对象的频率特性分析产生较大偏差。为此,提出了电网故障下DDWT锁相偏差的量化方法;解析了锁相偏差经DDWT变流器控制的传导路径,提出了锁相暂态响应导致DDWT功率控制误差的机理及其计算方法;建立了电网故障下含DDWT的电力系统频率响应模型,提出了锁相暂态响应影响下系统频率变化率和最大频率偏差的计算方法,解析了电网故障下考虑DDWT功率控制误差的电力系统频率动态响应特性,并通过算例分析验证了所提方法的有效性。 展开更多
关键词 直驱风电机组(ddwt) 频率动态响应 电网故障 锁相环 暂态响应 功率控制
下载PDF
Accurate 3D Thermal Network Development for Direct-drive Outer-rotor Hybrid-PM Flux-switching Generator
4
作者 Ali Zarghani Mohammad Farahzadi +1 位作者 Aghil Ghaheri Karim Abbaszadeh 《Chinese Journal of Electrical Engineering》 EI CSCD 2024年第2期80-92,共13页
Heat and thermal problems are major obstacles to achieving high power density in compact permanent magnet(PM)topologies.Consequently,a comprehensive,accurate,and rapid temperature rise estimation method is required fo... Heat and thermal problems are major obstacles to achieving high power density in compact permanent magnet(PM)topologies.Consequently,a comprehensive,accurate,and rapid temperature rise estimation method is required for novel electric machines to ensure safe and reliable operations.A unique three-dimensional(3D)lumped parameter thermal network(LPTN)is presented for accurate thermal modeling of a newly developed outer-rotor hybrid-PM flux switching generator(OR-HPMFSG)for direct-drive applications.First,the losses of the OR-HPMFSG are calculated using 3D finite element analysis(FEA).Subsequently,all machine components considering the thermal contact resistance,anisotropic thermal conductivity of materials,and various heat flow paths are comprehensively modeled based on the thermal resistances.In the proposed 3-D LPTN,internal nodes are considered to predict the average temperature as well as the hot spots of all active and passive components.Experimental measurements are performed on a prototype OR-HPMFSG to validate the efficiency of the 3-D LPTN.A comparison of the results at various operating points between the developed 3-D LPTN,experimental test,and FEA indicates that the 3-D LPTN quickly approximates the hotspot and mean temperature of all components under both transient and steady states with high accuracy. 展开更多
关键词 direct-drive wind turbine hybrid-PM flux switching generator lumped parameter thermal network temperature estimation 3D thermal modeling
原文传递
Multi-objective design optimization of a large-scale directdrive permanent magnet generator for wind energy conversion systems
5
作者 Arash Hasssanpour ISFAHANI Amirhossein Haji-Seyed BOROUJERDI Saeed HASANZADEH 《Frontiers in Energy》 SCIE CSCD 2014年第2期182-191,共10页
This paper presents a simukaneous multi- objective optimization of a direct-drive permanent magnet synchronous generator and a three-blade horizontal-axis wind turbine for a large scale wind energy conversion system. ... This paper presents a simukaneous multi- objective optimization of a direct-drive permanent magnet synchronous generator and a three-blade horizontal-axis wind turbine for a large scale wind energy conversion system. Analytical models of the generator and the turbine are used along with the cost model for optimization. Three important characteristics of the system i.e.,the total cost of the generator and blades, the annual energy output and the total mass of generator and blades are chosen as objective functions for a multi-objective optimization. Genetic algorithm (GA) is then employed to optimize the value of eight design parameters including seven generator parameters and a turbine parameter resulting in a set of Pareto optimal solutions. Four optimal solutions are then selected by applying some practical restrictions on the Pareto front. One of these optimal designs is chosen for finite element verification. A circuit-fed coupled time stepping finite element method is then performed to evaluate the no-load and the full load performance analysis of the system including the generator, a rectifier and a resistive load. The results obtained by the finite element analysis (FEA) verify the accuracy of the analytical model and the proposed method. 展开更多
关键词 permanent magnet synchronous generator wind turbine direct-drive multi-objective optimization
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部