Aiming at the shortcomings of the existing electric energy metering method,combining with the harmonic responsibility analysis model based on the reference impedance method and the idea of apparent power decomposition...Aiming at the shortcomings of the existing electric energy metering method,combining with the harmonic responsibility analysis model based on the reference impedance method and the idea of apparent power decomposition in IEEE Std 1459-2010 standard,two new metering indicators—billing active power and billing power factor are defined.A new electric energy metering method is proposed and its specific implementation steps are given.The simulation model is built in Matlab/Simulink,and three different examples are set up.Using the simulation data,the various metering indicators need to be examined by the existing electric energy metering method and the new electric energy metering method are calculated.The calculation results show that the new electric energy metering method not only overcomes the shortcomings of the existing electric energy metering method,but also is very easy to be popularized and applied.展开更多
This article puts forward an automatic recognition algorithm of electric energy meter lead seals: firstly, the image will be histogram equalization, smoothing, binaryzation pretreatment, then according to the image c...This article puts forward an automatic recognition algorithm of electric energy meter lead seals: firstly, the image will be histogram equalization, smoothing, binaryzation pretreatment, then according to the image characteristics of text changes, the system can quickly and accurately segment image from complex background, finally the system extract different dimension and the feature of English and Arabia using digital projection transform coefficient method and to identify the corresponding number by BP neural network, solves the problem of automatic recognition of electric energy meter lead sealing.展开更多
This paper analyzes the actual situation of the electricity management about student apartments, and design intelligent energy student housing management system based on CAN bus. The system uses the field level, the u...This paper analyzes the actual situation of the electricity management about student apartments, and design intelligent energy student housing management system based on CAN bus. The system uses the field level, the underlying management level and upper management level three management system. Field level with a dedicated energy metering chip AD7755 and STM32F103 microcontroller with A/D conversion function as the core, to achieve real-time power measurement; via CAN bus timing or random read live energy data for monitoring electricity consumption of the apartment, investigate abnormal electricity, thus effectively limiting the students to use electrical power to achieve the modernization and automation of power management solutions student apartments.展开更多
With the increasing development of urban housing construction and the rapid expansion of the number of inhabitants and independent electric energy meter, a variety of tariff systems are launched, meter reading meterin...With the increasing development of urban housing construction and the rapid expansion of the number of inhabitants and independent electric energy meter, a variety of tariff systems are launched, meter reading metering becomes increasingly complex, and the traditional manual meter reading is already hard to adapt to new changes. This thesis studies the design of a centralized meter reading system. This program applies PLC technology for information transfer, which guarantees the stability of system carrier communication. This system is composed of electric energy meter, collector, concentrator and other hardware, as well as communication and management software of collection copies system. It is characterized by functions of power data collection, centralization, remote transmission, distance control, electricity analysis, line loss calculation, integrated query, and time-sharing billing. Its promotion and application will necessarily provide important technical means for power supply, property and urban utilities to improve their modernized and automatic management level.展开更多
基金National Natural Science Foundation of China(No.51367010)Science and Technology Program of Gansu Province(No.17JR5RA083)+1 种基金Program for Excellent Team of Scientific Research of Lanzhou Jiaotong University(No.201701)Scientific Research Program of Colleges and Universities of Gansu Province(No.2016B-032)。
文摘Aiming at the shortcomings of the existing electric energy metering method,combining with the harmonic responsibility analysis model based on the reference impedance method and the idea of apparent power decomposition in IEEE Std 1459-2010 standard,two new metering indicators—billing active power and billing power factor are defined.A new electric energy metering method is proposed and its specific implementation steps are given.The simulation model is built in Matlab/Simulink,and three different examples are set up.Using the simulation data,the various metering indicators need to be examined by the existing electric energy metering method and the new electric energy metering method are calculated.The calculation results show that the new electric energy metering method not only overcomes the shortcomings of the existing electric energy metering method,but also is very easy to be popularized and applied.
文摘This article puts forward an automatic recognition algorithm of electric energy meter lead seals: firstly, the image will be histogram equalization, smoothing, binaryzation pretreatment, then according to the image characteristics of text changes, the system can quickly and accurately segment image from complex background, finally the system extract different dimension and the feature of English and Arabia using digital projection transform coefficient method and to identify the corresponding number by BP neural network, solves the problem of automatic recognition of electric energy meter lead sealing.
文摘This paper analyzes the actual situation of the electricity management about student apartments, and design intelligent energy student housing management system based on CAN bus. The system uses the field level, the underlying management level and upper management level three management system. Field level with a dedicated energy metering chip AD7755 and STM32F103 microcontroller with A/D conversion function as the core, to achieve real-time power measurement; via CAN bus timing or random read live energy data for monitoring electricity consumption of the apartment, investigate abnormal electricity, thus effectively limiting the students to use electrical power to achieve the modernization and automation of power management solutions student apartments.
文摘With the increasing development of urban housing construction and the rapid expansion of the number of inhabitants and independent electric energy meter, a variety of tariff systems are launched, meter reading metering becomes increasingly complex, and the traditional manual meter reading is already hard to adapt to new changes. This thesis studies the design of a centralized meter reading system. This program applies PLC technology for information transfer, which guarantees the stability of system carrier communication. This system is composed of electric energy meter, collector, concentrator and other hardware, as well as communication and management software of collection copies system. It is characterized by functions of power data collection, centralization, remote transmission, distance control, electricity analysis, line loss calculation, integrated query, and time-sharing billing. Its promotion and application will necessarily provide important technical means for power supply, property and urban utilities to improve their modernized and automatic management level.