Electromagnetic coil launch is an important branch of electromagnetic launch(EML)technology,which is suitable for launching anti-torpedo torpedo(ATT).This paper focuses on the EML parameters and the interception proba...Electromagnetic coil launch is an important branch of electromagnetic launch(EML)technology,which is suitable for launching anti-torpedo torpedo(ATT).This paper focuses on the EML parameters and the interception probability of the EML two ATTs salvo.Based on the launching model of a multi-stage coil launcher,the trajectory model of the ATT and the attacking torpedo,a calculation method for the EML two ATTs salvo parameters is proposed,with the conditions of capture and interception given reasonably.An adaptive particle swarm optimization(APSO)algorithm is proposed to calculate the optimal launching parameters,by designing the adaptive inertia weight and time-varying study factors.According to the analysis of the simulation with Monte Carlo method,EML will improve the interception probability effectively,and the interception probability is affected by the launching range.The results demonstrate good performance of the proposed APSO in calculating EML parameters for the two ATTs salvo in certain combat situation.Implications of these results are particular regarding the command and decision in the anti-torpedo combat.展开更多
The electromagnetic concentrative coils are indispensable in the functional magnetic stimulation and have potential applications in nondestructive testing. In this paper, we propose a figure-8-shaped coil being compos...The electromagnetic concentrative coils are indispensable in the functional magnetic stimulation and have potential applications in nondestructive testing. In this paper, we propose a figure-8-shaped coil being composed of two arbitrary oblique elliptical coils, which can change the electromagnetic concentrative region and the magnitude of eddy current density by changing the elliptical shape and/or spread angle between two elliptical coils. Pulsed current is usually the excitation source in the functional magnetic stimulation, so in this paper we derive the analytical solutions of transient pulsed eddy current field in the time domain due to the elliptical concentrative coil placed in an arbitrary position over a half-infinite plane conductor by making use of the scale-transformation, the Laplace transform and the Fourier transform are used in our derivation. Calculation results of field distributions produced by the figure-8-shaped elliptical coil show some behaviours as follows: 1) the eddy currents are focused on the conductor under the geometric symmetric centre of figure-8-shaped coil; 2) the greater the scale factor of ellipse is, the higher the eddy current density is and the wider the concentrative area of eddy current along y axis is; 3) the maximum magnitude of eddy current density increases with the increase of spread angle. When spread angle is 180°, there are two additional reverse concentrative areas on both sides of x axis.展开更多
In a fusion reactor, the edge localized mode(ELM) coil has a mitigating effect on the ELMs of the plasma. The coil is placed close to the plasma between the vacuum vessel and the blanket to reduce its design power a...In a fusion reactor, the edge localized mode(ELM) coil has a mitigating effect on the ELMs of the plasma. The coil is placed close to the plasma between the vacuum vessel and the blanket to reduce its design power and improve its mitigating ability. The coil works in a high-temperature,high-nuclear-heat and high-magnetic-field environment. Due to the existence of outer superconducting coils, the coil is subjected to an alternating electromagnetic force induced by its own alternating current and the outer magnetic field. The design goal for the ELM coil is to maintain its structural integrity in the multi-physical field. Taking as an example the middle ELM coil(with flexible supports) of ITER(the International Thermonuclear Fusion Reactor), an electromagnetic–thermal–structural coupling analysis is carried out using ANSYS. The results show that the flexible supports help the three-layer casing meet the static and fatigue design requirements. The structural design of the middle ELM coil is reasonable and feasible. The work described in this paper provides the theoretical basis and method for ELM coil design.展开更多
The seismic activities on the Earth can produce a disturbance of the electromagnetic field and particles in the ionosphere. The search coil magnetometer(SCM) mounted on China Seismo-Electromagnetic satellite(CSES) is ...The seismic activities on the Earth can produce a disturbance of the electromagnetic field and particles in the ionosphere. The search coil magnetometer(SCM) mounted on China Seismo-Electromagnetic satellite(CSES) is designed to measure the magnetic field fluctuation of low frequency electromagnetic waves in the frequency range of 10 Hz–20 k Hz. The SCM comprises a three-axis search coil sensor mounted on a 4.5 m boom and an electronic box inside satellite module. The sampling rate of the SCM is 51.2 k Hz and the time resolution of the power spectrum density(PSD) is 2 s. The frequency resolution is 12.5 Hz.There are three operation modes: survey, detailed survey and calibration. In the survey mode, the SCM can provide a PSD in the whole frequency range of 10 Hz–20 k Hz and wave forms in the low frequency range below 2 k Hz while in the detailed survey mode the SCM can provide both PSD and wave forms in the whole frequency range of 10 Hz–20 k Hz. The sensitivity of the SCM instrument is 5.0×10^(-4) n T Hz^(-1/2) at 10 Hz, 5.0×10^(–5) n T Hz^(-1/2) at 200 Hz, 3.4×10^(-5) n T Hz^(-1/2) at 2 k Hz and 1.1×10^(-4) n T Hz^(-1/2) at 20 k Hz. The telemetry rate is ~0.85 Mbps in the survey mode and ~3.0 Mbps in the detailed survey mode. The phase difference between three axes can be made generally with a precision of less than 1.0°. The dynamic range of the SCM instrument is over 100 d B. The orthogonality of three mechanical axes of search coil senor is better than 0.13°. The performance of SCM can satisfy the requirement of scientific objectives of CSES mission.展开更多
A novel electromagnetic induction detector with two inductors for CE was described here.The two inductors were used as signal detection and reference,respectively.The parameters affecting the detector performance(inc...A novel electromagnetic induction detector with two inductors for CE was described here.The two inductors were used as signal detection and reference,respectively.The parameters affecting the detector performance(including coil turns,detection distance, excitation frequency,voltage,etc.) were optimized.Under the optimum condition,the feasibility of the detector was examined by analyzing inorganic ions.The fabricated detector showed good linear relationship between the response and the analytes concentrations,with a detection limit of 13μmol/L for Na~+(S/N = 3).A variety of advantages,such as simple construction, ease of operation,and considerably universal response,suggested this novel detector a promising application prospect in analytical area.展开更多
基金National Natural Science Foundation of China (Grant No. 51777212)
文摘Electromagnetic coil launch is an important branch of electromagnetic launch(EML)technology,which is suitable for launching anti-torpedo torpedo(ATT).This paper focuses on the EML parameters and the interception probability of the EML two ATTs salvo.Based on the launching model of a multi-stage coil launcher,the trajectory model of the ATT and the attacking torpedo,a calculation method for the EML two ATTs salvo parameters is proposed,with the conditions of capture and interception given reasonably.An adaptive particle swarm optimization(APSO)algorithm is proposed to calculate the optimal launching parameters,by designing the adaptive inertia weight and time-varying study factors.According to the analysis of the simulation with Monte Carlo method,EML will improve the interception probability effectively,and the interception probability is affected by the launching range.The results demonstrate good performance of the proposed APSO in calculating EML parameters for the two ATTs salvo in certain combat situation.Implications of these results are particular regarding the command and decision in the anti-torpedo combat.
基金Project supported by the National Natural Science Foundation of China (Grant No. 50807001)
文摘The electromagnetic concentrative coils are indispensable in the functional magnetic stimulation and have potential applications in nondestructive testing. In this paper, we propose a figure-8-shaped coil being composed of two arbitrary oblique elliptical coils, which can change the electromagnetic concentrative region and the magnitude of eddy current density by changing the elliptical shape and/or spread angle between two elliptical coils. Pulsed current is usually the excitation source in the functional magnetic stimulation, so in this paper we derive the analytical solutions of transient pulsed eddy current field in the time domain due to the elliptical concentrative coil placed in an arbitrary position over a half-infinite plane conductor by making use of the scale-transformation, the Laplace transform and the Fourier transform are used in our derivation. Calculation results of field distributions produced by the figure-8-shaped elliptical coil show some behaviours as follows: 1) the eddy currents are focused on the conductor under the geometric symmetric centre of figure-8-shaped coil; 2) the greater the scale factor of ellipse is, the higher the eddy current density is and the wider the concentrative area of eddy current along y axis is; 3) the maximum magnitude of eddy current density increases with the increase of spread angle. When spread angle is 180°, there are two additional reverse concentrative areas on both sides of x axis.
基金the Province Postdoctoral Foundation of Jiangsu(1501164B)the Technical Innovation Nurturing Foundation of Yangzhou University(2015CXJ016)China Postdoctoral Science Foundation(2016M600447)
文摘In a fusion reactor, the edge localized mode(ELM) coil has a mitigating effect on the ELMs of the plasma. The coil is placed close to the plasma between the vacuum vessel and the blanket to reduce its design power and improve its mitigating ability. The coil works in a high-temperature,high-nuclear-heat and high-magnetic-field environment. Due to the existence of outer superconducting coils, the coil is subjected to an alternating electromagnetic force induced by its own alternating current and the outer magnetic field. The design goal for the ELM coil is to maintain its structural integrity in the multi-physical field. Taking as an example the middle ELM coil(with flexible supports) of ITER(the International Thermonuclear Fusion Reactor), an electromagnetic–thermal–structural coupling analysis is carried out using ANSYS. The results show that the flexible supports help the three-layer casing meet the static and fatigue design requirements. The structural design of the middle ELM coil is reasonable and feasible. The work described in this paper provides the theoretical basis and method for ELM coil design.
基金supported by the National Natural Science Foundation of China(Grant No.41431071)
文摘The seismic activities on the Earth can produce a disturbance of the electromagnetic field and particles in the ionosphere. The search coil magnetometer(SCM) mounted on China Seismo-Electromagnetic satellite(CSES) is designed to measure the magnetic field fluctuation of low frequency electromagnetic waves in the frequency range of 10 Hz–20 k Hz. The SCM comprises a three-axis search coil sensor mounted on a 4.5 m boom and an electronic box inside satellite module. The sampling rate of the SCM is 51.2 k Hz and the time resolution of the power spectrum density(PSD) is 2 s. The frequency resolution is 12.5 Hz.There are three operation modes: survey, detailed survey and calibration. In the survey mode, the SCM can provide a PSD in the whole frequency range of 10 Hz–20 k Hz and wave forms in the low frequency range below 2 k Hz while in the detailed survey mode the SCM can provide both PSD and wave forms in the whole frequency range of 10 Hz–20 k Hz. The sensitivity of the SCM instrument is 5.0×10^(-4) n T Hz^(-1/2) at 10 Hz, 5.0×10^(–5) n T Hz^(-1/2) at 200 Hz, 3.4×10^(-5) n T Hz^(-1/2) at 2 k Hz and 1.1×10^(-4) n T Hz^(-1/2) at 20 k Hz. The telemetry rate is ~0.85 Mbps in the survey mode and ~3.0 Mbps in the detailed survey mode. The phase difference between three axes can be made generally with a precision of less than 1.0°. The dynamic range of the SCM instrument is over 100 d B. The orthogonality of three mechanical axes of search coil senor is better than 0.13°. The performance of SCM can satisfy the requirement of scientific objectives of CSES mission.
基金support from the National Natural Science Foundation of China(Nos20727006 and 21075139)
文摘A novel electromagnetic induction detector with two inductors for CE was described here.The two inductors were used as signal detection and reference,respectively.The parameters affecting the detector performance(including coil turns,detection distance, excitation frequency,voltage,etc.) were optimized.Under the optimum condition,the feasibility of the detector was examined by analyzing inorganic ions.The fabricated detector showed good linear relationship between the response and the analytes concentrations,with a detection limit of 13μmol/L for Na~+(S/N = 3).A variety of advantages,such as simple construction, ease of operation,and considerably universal response,suggested this novel detector a promising application prospect in analytical area.