To accurately obtain development dynamic data such as zonal pressure and fluid parameters of each oil layer in the late development stage of a high water-cut old oilfield, a modular zonal sampling and testing technolo...To accurately obtain development dynamic data such as zonal pressure and fluid parameters of each oil layer in the late development stage of a high water-cut old oilfield, a modular zonal sampling and testing technology with the characteristics of modularization, full electronic control and rapidity was proposed and developed. Lab testing and on-site testing was carried out. The modular zonal sampling and testing system is composed of 10 functional modules, namely ground control system, downhole power supply module, drainage pump, electronically controlled anchor, electronically controlled packer, electronically controlled sampler, magnetic positioning sub, terminal sub, adapter cable, and quick connector. Indoor tests have confirmed that the performance parameters of each module meet the design requirements. The downhole function modules of the system can withstand pressures up to 35 MPa and temperatures up to 85 ℃. The rubber cylinder of the electronically controlled packer can withstand a pressure difference of more than 10 MPa. The electronically controlled anchor has an anchoring force of greater than 6.9 t, and can be forcibly detached in the event of an accident. The discharge pump has a displacement of 0.8 m;/d and a head of 500 m. The electronically controlled sampler can meet the requirement of taking 500 mL of sample in each of the 3 chambers. Field tests in Jilin Oilfield show that the system can realize rapid isolation and self-check of isolation of a certain production interval downhole, as well as layer-by layer pressure build-up test. The drainage pump can be used to discharge the mixed liquid between the upper and lower packers and near the wellbore to obtain real fluid samples of the tested formation interval. The data obtained give us better understanding on the pay zones in old oilfields, and provide important basis for development plan adjustment, reservoir stimulation, and EOR measures.展开更多
Formation testing while drilling is an innovative technique that is replacing conventional pressure testing in which the fluid sampling is conducted in a relatively short time following the drilling. At this time, mud...Formation testing while drilling is an innovative technique that is replacing conventional pressure testing in which the fluid sampling is conducted in a relatively short time following the drilling. At this time, mud invasion has just started, mudcake has not formed entirely and the formation pressure is not stable. Therefore, it is important to study the influence of the downhole dynamic environment on pressure testing and fluid sampling. This paper applies an oil-water two phase finite element model to study the influence of mudcake quality and mud filtrate invasion on supercharge pressure, pretest and sampling in the reservoirs of different permeability. However, the study is only for the cases with water based mud in the wellbore. The results illustrate that the mudcake quality has a significant influence on the supercharge pressure and fluid sampling, while the level of mud filtrate invasion has a strong impact on pressure testing and sampling. In addition, in-situ formation pressure testing is more difficult in low permeability reservoirs as the mud filtrate invasion is deeper and therefore degrades the quality of fluid sampling. Finally, a field example from an oil field on the Alaskan North Slope is presented to validate the numerical studies of the effects of downhole dynamic conditions on formation testing while drilling.展开更多
Intraventricular metastases are a rare occurrence,particularly from a primary colorectal malignancy.To our knowledge,this is the first report of intraventricular metastasis from rectal cancer.A 72-year-old male presen...Intraventricular metastases are a rare occurrence,particularly from a primary colorectal malignancy.To our knowledge,this is the first report of intraventricular metastasis from rectal cancer.A 72-year-old male presented with a new diagnosis of multiple intraventricular lesions,an anterior mediastinal mass and a rectal mass.His workup revealed rectal adenocarcinoma with intraventricular metastases and an incidental thymoma.Ommaya reservoir placement was performed via an awake procedure rather than under general anesthesia due to airway concerns.Cerebrospinal fluid(CSF) cytology was positive for malignancy and consistent with adenocarcinoma.Two weeks postoperatively,the patient underwent whole brain radiation.Although rare,this diagnosis should always be considered in the differential for solitary or multiple intraventricular lesions.CSF sampling is a useful alternative to intraventricular biopsy for diagnosis of intraventricular metastases.Awake placement of Ommaya reservoir is a safe option in the management of patients with intraventricular metastases,especially those who cannot undergo general anesthesia.展开更多
A novel method applying simple, rapid, effective and inexpensive excitation-emission matrix (EEM) fluorescence spectroscopy coupled with second-order calibration method for simultaneous determination of ethoxyquin ...A novel method applying simple, rapid, effective and inexpensive excitation-emission matrix (EEM) fluorescence spectroscopy coupled with second-order calibration method for simultaneous determination of ethoxyquin (EQ) and tert-butylhydroquinone (TBHQ) contents in biological fluid samples was developed. After a simple data preprocessing that was to insert zeros below the first-order Rayleigh scattering, the second-order calibration method based on the alternating normalization-weighed error (ANWE) algorithm was used to deal with EEM data. Via the introduced "second-order advantage", the individual con- centrations of the analytes of interest could be obtained even in the presence of uncalibrated interferences. The experimental concentration ranges for the analytes were as follows: EQ, from 4.58 to 20.6 p.g mL-1 in plasma and from 6.87 to 20.6 gg mL-1 in urine; TBHQ, from 4.49 to 20.2 ~tg mL-1 in plasma and from 6.73 to 22.4 I.tg mL-l in urine. The recoveries from spiked bi- ological fluid samples were in the ranges of 92.8%-106.2% for EQ and 94.6%-107.2% for TBHQ. These results demonstrate that the three-dimensional EEM fluorescence with second-order calibration method is a powerful tool for obtaining both EQ and TBHQ quantitative results in plasma and urine samples, and could be applied to more complex matrices.展开更多
基金Supported by the Project of Basic Science Center of National Natural Science Foundation of China (72088101)Major Project of CNPC (2021ZG12)+1 种基金National Key R&D Program/Key Project of Intergovernmental International Scientific and Technological Innovation Cooperation (2018YFE0196000)Major Scientific and Technological Project of PetroChina Jilin Oilfield Company (JY21A2-12)。
文摘To accurately obtain development dynamic data such as zonal pressure and fluid parameters of each oil layer in the late development stage of a high water-cut old oilfield, a modular zonal sampling and testing technology with the characteristics of modularization, full electronic control and rapidity was proposed and developed. Lab testing and on-site testing was carried out. The modular zonal sampling and testing system is composed of 10 functional modules, namely ground control system, downhole power supply module, drainage pump, electronically controlled anchor, electronically controlled packer, electronically controlled sampler, magnetic positioning sub, terminal sub, adapter cable, and quick connector. Indoor tests have confirmed that the performance parameters of each module meet the design requirements. The downhole function modules of the system can withstand pressures up to 35 MPa and temperatures up to 85 ℃. The rubber cylinder of the electronically controlled packer can withstand a pressure difference of more than 10 MPa. The electronically controlled anchor has an anchoring force of greater than 6.9 t, and can be forcibly detached in the event of an accident. The discharge pump has a displacement of 0.8 m;/d and a head of 500 m. The electronically controlled sampler can meet the requirement of taking 500 mL of sample in each of the 3 chambers. Field tests in Jilin Oilfield show that the system can realize rapid isolation and self-check of isolation of a certain production interval downhole, as well as layer-by layer pressure build-up test. The drainage pump can be used to discharge the mixed liquid between the upper and lower packers and near the wellbore to obtain real fluid samples of the tested formation interval. The data obtained give us better understanding on the pay zones in old oilfields, and provide important basis for development plan adjustment, reservoir stimulation, and EOR measures.
基金supported by the National Natural Science Foundation of China (No. 50674098)Major Project of Chinese Science and Technology (No. 2011ZX 05000-020-04)Major Project of SINOPEC Science and Technology (No. P13147)
文摘Formation testing while drilling is an innovative technique that is replacing conventional pressure testing in which the fluid sampling is conducted in a relatively short time following the drilling. At this time, mud invasion has just started, mudcake has not formed entirely and the formation pressure is not stable. Therefore, it is important to study the influence of the downhole dynamic environment on pressure testing and fluid sampling. This paper applies an oil-water two phase finite element model to study the influence of mudcake quality and mud filtrate invasion on supercharge pressure, pretest and sampling in the reservoirs of different permeability. However, the study is only for the cases with water based mud in the wellbore. The results illustrate that the mudcake quality has a significant influence on the supercharge pressure and fluid sampling, while the level of mud filtrate invasion has a strong impact on pressure testing and sampling. In addition, in-situ formation pressure testing is more difficult in low permeability reservoirs as the mud filtrate invasion is deeper and therefore degrades the quality of fluid sampling. Finally, a field example from an oil field on the Alaskan North Slope is presented to validate the numerical studies of the effects of downhole dynamic conditions on formation testing while drilling.
文摘Intraventricular metastases are a rare occurrence,particularly from a primary colorectal malignancy.To our knowledge,this is the first report of intraventricular metastasis from rectal cancer.A 72-year-old male presented with a new diagnosis of multiple intraventricular lesions,an anterior mediastinal mass and a rectal mass.His workup revealed rectal adenocarcinoma with intraventricular metastases and an incidental thymoma.Ommaya reservoir placement was performed via an awake procedure rather than under general anesthesia due to airway concerns.Cerebrospinal fluid(CSF) cytology was positive for malignancy and consistent with adenocarcinoma.Two weeks postoperatively,the patient underwent whole brain radiation.Although rare,this diagnosis should always be considered in the differential for solitary or multiple intraventricular lesions.CSF sampling is a useful alternative to intraventricular biopsy for diagnosis of intraventricular metastases.Awake placement of Ommaya reservoir is a safe option in the management of patients with intraventricular metastases,especially those who cannot undergo general anesthesia.
基金the National Natural Science Foundation of China (21175041)the National Basic Research Program(2012CB910602) for financial support
文摘A novel method applying simple, rapid, effective and inexpensive excitation-emission matrix (EEM) fluorescence spectroscopy coupled with second-order calibration method for simultaneous determination of ethoxyquin (EQ) and tert-butylhydroquinone (TBHQ) contents in biological fluid samples was developed. After a simple data preprocessing that was to insert zeros below the first-order Rayleigh scattering, the second-order calibration method based on the alternating normalization-weighed error (ANWE) algorithm was used to deal with EEM data. Via the introduced "second-order advantage", the individual con- centrations of the analytes of interest could be obtained even in the presence of uncalibrated interferences. The experimental concentration ranges for the analytes were as follows: EQ, from 4.58 to 20.6 p.g mL-1 in plasma and from 6.87 to 20.6 gg mL-1 in urine; TBHQ, from 4.49 to 20.2 ~tg mL-1 in plasma and from 6.73 to 22.4 I.tg mL-l in urine. The recoveries from spiked bi- ological fluid samples were in the ranges of 92.8%-106.2% for EQ and 94.6%-107.2% for TBHQ. These results demonstrate that the three-dimensional EEM fluorescence with second-order calibration method is a powerful tool for obtaining both EQ and TBHQ quantitative results in plasma and urine samples, and could be applied to more complex matrices.