In this study, four 1/5 scaled shaking table tests were conducted to investigate the seismic performance of recycled concrete frame-shear wall structures with different recycled aggregates replacement rates and concea...In this study, four 1/5 scaled shaking table tests were conducted to investigate the seismic performance of recycled concrete frame-shear wall structures with different recycled aggregates replacement rates and concealed bracing detail. The four tested structures included one normal concrete model, one recycled coarse aggregate concrete model, and two recycled coarse and fi ne aggregate concrete models with or without concealed bracings inside the shear walls. The dynamic characteristics, dynamic response and failure mode of each model were compared and analyzed. Finite element models were also developed and nonlinear time-history response analysis was conducted. The test and analysis results show that the seismic performance of the recycled coarse aggregate concrete frame-shear wall structure is slightly worse than the normal concrete structure. The seismic resistance capacity of the recycled concrete frame-shear wall structure can be greatly improved by setting up concealed bracings inside the walls. With appropriate design, the recycled coarse aggregate concrete frame-shear wall structure and recycled concrete structure with concealed bracings inside the walls can be applied in buildings.展开更多
Efficient methods for incorporating engineering experience into the intelligent generation and optimization of shear wall structures are lacking,hindering intelligent design performance assessment and enhancement.This...Efficient methods for incorporating engineering experience into the intelligent generation and optimization of shear wall structures are lacking,hindering intelligent design performance assessment and enhancement.This study introduces an assessment method used in the intelligent design and optimization of shear wall structures that effectively combines mechanical analysis and formulaic encoding of empirical rules.First,the critical information about the structure was extracted through data structuring.Second,an empirical rule assessment method was developed based on the engineer's experience and design standards to complete a preliminary assessment and screening of the structure.Subsequently,an assessment method based on mechanical performance and material consumption was used to compare different structural schemes comprehensively.Finally,the assessment effectiveness was demonstrated using a typical case.Compared to traditional assessment methods,the proposed method is more comprehensive and significantly more efficient,promoting the intelligent transformation of structural design.展开更多
The relationship between the in the logarithmic law (log-law) region of bursting event and the low/high-speed streak a turbulent boundary layer is investigated. A tomographic time-resolved particle image velocimetry...The relationship between the in the logarithmic law (log-law) region of bursting event and the low/high-speed streak a turbulent boundary layer is investigated. A tomographic time-resolved particle image velocimetry (TRPIV) system is used to measure the instantaneous three-dimensional-three-component (3D-3C) velocity field. The momentum thickness based Reynolds number is about 2 460. The topological information in the log-law region is obtained experimentally. It is found that the existence of the quadrupole topological structure implies a three-pair hairpin-like vortex packet, which is in connection with the low/high-speed streak. An idealized 3D topological model is then proposed to characterize the observed hairpin vortex packet and low/high-speed streak.展开更多
With the method of separation of variables and the eigenfunction expansion employed, an analytical solution is presented for the radiation and diffraction of a rectangular structure with an opening near a vertical wal...With the method of separation of variables and the eigenfunction expansion employed, an analytical solution is presented for the radiation and diffraction of a rectangular structure with an opening near a vertical wall in oblique seas, in which the unknown coefficients are determined by the boundary conditions and matching requirement on the interface. The effects of the width of the opening and the angle of incidence on the hydrodynamic characteristics of a rectangular structure with an opening near a vertical wall are mainly studied. The comparisons of the calculation results with wall-present and with wall-absent are also made. The results indicate that the variation trends of the heave added mass and excitation force with wall-present are almost the same as those with wall-absent, and that the peak values in the former case are obviously larger than those in the latter due to the reflection of the vertical wall.展开更多
Mixed-type structures combining the advantages of pile constructions(low material consumption and possibility to erect on weak soils)and gravity walls(high bearing capacity and stability,good reliability and durabilit...Mixed-type structures combining the advantages of pile constructions(low material consumption and possibility to erect on weak soils)and gravity walls(high bearing capacity and stability,good reliability and durability)are considered and improved.The sphere of application,main peculiarities,and practical technological aspects of these structures’implementation are analyzed.展开更多
The present work aims to assess earthquake-induced earth-retaining(ER)wall displacement.This study is on the dynamics analysis of various earth-retaining wall designs in hollow precast concrete panels,reinforcement co...The present work aims to assess earthquake-induced earth-retaining(ER)wall displacement.This study is on the dynamics analysis of various earth-retaining wall designs in hollow precast concrete panels,reinforcement concrete facing panels,and gravity-type earth-retaining walls.The finite element(FE)simulations utilized a 3D plane strain condition to model full-scale ER walls and numerous nonlinear dynamics analyses.The seismic performance of differentmodels,which includes reinforcement concrete panels and gravity-type and hollowprecast concrete ER walls,was simulated and examined using the FE approach.It also displays comparative studies such as stress distribution,deflection of the wall,acceleration across the wall height,lateral wall displacement,lateral wall pressure,and backfill plastic strain.Three components of the created ER walls were found throughout this research procedure.One is a granular reinforcement backfill,while the other is a wall-facing panel and base foundation.The dynamic response effects of varied earth-retaining walls have also been studied.It was discovered that the facing panel of the model significantly impacts the earthquake-induced displacement of ER walls.The proposed analytical model’s validity has been evaluated and compared with the reinforcement concrete facing panels,gravity-type ER wall,scientifically available data,and American Association of State Highway and Transportation Officials(AASHTO)guidelines results based on FE simulation.The results of the observations indicate that the hollow prefabricated concrete ER wall is the most feasible option due to its lower displacement and high-stress distribution compared to the two types.The methodology and results of this study establish standards for future analogous investigations and professionals,particularly in light of the increasing computational capabilities of desktop computers.展开更多
Reinforced concrete(RC) load bearing wall is widely used in high-rise and mid-rise buildings. Due to the number of walls in plan and reduction in lateral force portion, this system is not only stronger against earthqu...Reinforced concrete(RC) load bearing wall is widely used in high-rise and mid-rise buildings. Due to the number of walls in plan and reduction in lateral force portion, this system is not only stronger against earthquakes, but also more economical. The effect of progressive collapse caused by removal of load bearing elements, in various positions in plan and stories of the RC load bearing wall system was evaluated by nonlinear dynamic and static analyses. For this purpose, three-dimensional model of 10-story structure was selected. The analysis results indicated stability, strength and stiffness of the RC load-bearing wall system against progressive collapse. It was observed that the most critical condition for removal of load bearing walls was the instantaneous removal of the surrounding walls located at the corners of the building where the sections of the load bearing elements were changed. In this case, the maximum vertical displacement was limited to 6.3 mm and the structure failed after applying the load of 10 times the axial load bored by removed elements. Comparison between the results of the nonlinear dynamic and static analyses demonstrated that the "load factor" parameter was a reasonable criterion to evaluate the progressive collapse potential of the structure.展开更多
BACKGROUND Inferior wall left ventricular aneurysms are rare,they develop after transmural myocardial infarction(MI)and may be associated with poorer prognosis.We present a unique case of a large aneurysm of the infer...BACKGROUND Inferior wall left ventricular aneurysms are rare,they develop after transmural myocardial infarction(MI)and may be associated with poorer prognosis.We present a unique case of a large aneurysm of the inferior wall complicated by ventricular tachycardia(VT)and requiring surgical resection and mitral valve replacement.CASE SUMMARY A 59-year-old male was admitted for VT one month after he had a delayed presentation for an inferior ST-segment elevation MI and was discovered to have a large true inferior wall aneurysm on echocardiography and confirmed on coronary computed tomography(CT)angiography.Due to the sustained VT,concern for aneurysm expansion,and persistent heart failure symptoms,the patient was referred for surgical resection of the aneurysm with patch repair,mitral valve replacement,and automated implantable cardioverter defibrillator insertion with significant improvement in functional and clinical status.CONCLUSION Inferior wall aneurysms are rare and require close monitoring to identify electrical or contractile sequelae.Coronary CT angiography can outline anatomic details and guide surgical intervention to ameliorate life-threatening complications and improve performance status.展开更多
If βN exceeds βNno-wall, the plasma will be unstable because of external kink and resistive wall mode (RWM). In this article, the effect of the passive structure and the toroidal rotation on the RWM stability in t...If βN exceeds βNno-wall, the plasma will be unstable because of external kink and resistive wall mode (RWM). In this article, the effect of the passive structure and the toroidal rotation on the RWM stability in the experimental advanced superconducting tokamak (EAST) are simulated with CHEASE and MARS codes. A model using a one-dimensional (1D) surface to present the effect of the passive plate is proved to be credible. The no wall fiN limit is about 3li, and the ideal wall βN limit is about 4.5li on EAST. It is found that the rotation near the q = 2 surface and the plasma edge affects the RWM more.展开更多
One new coordination polymer with the chemical formula [CoCu2L2·K2·1.5C2H5OH]n(H4L = 2-hydroxy-3-[(E)-({3-[(2-hydroxybenzoyl)amino]propyl}imino)methyl] benzoic acid) has been synthesized based on the...One new coordination polymer with the chemical formula [CoCu2L2·K2·1.5C2H5OH]n(H4L = 2-hydroxy-3-[(E)-({3-[(2-hydroxybenzoyl)amino]propyl}imino)methyl] benzoic acid) has been synthesized based on the slow diffusion method,and characterized by IR spectroscopy,thermalgravimetric and X-ray diffraction analysis.It crystallizes in the monoclinic system,space group P21/n with a = 11.98860(10),b = 24.4279(3),c = 14.9008(2) ,β = 104.7490(10)°,V = 4220.01(8) 3,Z = 2,Mr = 1009.94,Dc = 1.590 g/cm3,F(000) = 2056,μ(MoKα) = 1.649 mm-1,the final R = 0.0411 and wR = 0.1178 for 5920 observed reflections with I 2σ(I).The compound possesses a 2D brick wall structure constructed from trinuclear units.展开更多
Tests of hypervelocity projectile impact on double-wall structure were performed with the front wall ranging from 0.5 mm to 2.0 mm thick and different impact velocities. Smooth particle hydrodynamics (SPH) code in LS-...Tests of hypervelocity projectile impact on double-wall structure were performed with the front wall ranging from 0.5 mm to 2.0 mm thick and different impact velocities. Smooth particle hydrodynamics (SPH) code in LS-DYNA was employed for the simulation of hypervelocity impact on the double-wall structure. By using elementary shock wave theory, the experimental results above are analyzed. The analysis can provide an explanation for the penetration mechanism of hypervelocity projectile impact on double-wall structure about the effect of front wall thickness and impact velocity..展开更多
To discuss the structure design and optimization of building curtain wall, the dynamic characteristics of point supported glass curtain wall system are analyzed by the finite element method. The various technologies a...To discuss the structure design and optimization of building curtain wall, the dynamic characteristics of point supported glass curtain wall system are analyzed by the finite element method. The various technologies are made use of, and according to the characteristics of the structure system, the finite element analysis model with steel structure glass plate beam element and shell element as the basic elements is established. Then, the dynamic characteristics are analyzed, and the modal parameters such as inherent frequency and vibration type are identified. The research results show that the node displacement response power spectrum under the load of wind is obtained, which provides the basis for rationally optimizing the structure. Based on the above findings, it is concluded that the optimization design based on finite element model has a wide significance, which is a useful attempt to reduce the blindness of design and has great engineering significance and application value.展开更多
Abstract Experiments were conducted in a water tunnel by tomographic time-resolved particle image velocimetry (Tomo-TRPIV). The Reynolds number Reo is 2 460 on the base of momentum thickness. According to the physic...Abstract Experiments were conducted in a water tunnel by tomographic time-resolved particle image velocimetry (Tomo-TRPIV). The Reynolds number Reo is 2 460 on the base of momentum thickness. According to the physical mechanism of the stretch and compression of multi-scale vortex structures in the wall-bounded turbulence, the topological characteristics of turbulence statistics in logarithmic layer were illustrated by local-averaged velocity structure function. During coherent structures bursting, results reveal that the topological structures of velocity gradients, velocity strain rates and vorticities behave as antisymmetric quadrupole modes. A three-layer antisymmetric quadrupole vortex packet confirms that there is a tight relationship between the outer layer and the near-wall layer.展开更多
Perhaps the best way to demonstrate the gained improvements in seismic performance of buildings, integrated with IDRIZI infill walls, is to analyse typical building structures subjected to real case earthquake scenari...Perhaps the best way to demonstrate the gained improvements in seismic performance of buildings, integrated with IDRIZI infill walls, is to analyse typical building structures subjected to real case earthquake scenarios. This paper presents obtained analytical results for a characteristic 2D frame structure which (besides the self-weight, superimposed dead loads and live loads) is subjected to real earthquake ground motions. This study case treats three story planar RC (reinforced concrete) frame opened on the ground story while its upper stories are infilled with classical masonry walls. The purpose of this study case is to demonstrate "quantitatively" the seismic performance of this frame structure and, more importantly, to estimate the level of seismic response improvements of the frame when at its ground story is utilized IDRIZI infill wall with door opening. The seismic action considered for this study case is a representation of the 1979 Tivari earthquake, Montenegro. Ultimately, this study demonstrates the remarkable benefits the structure gains (in terms of seismic performance and safety) by the use of IDRIZI wall system as a constitutive part of the 2D frame structure.展开更多
An experimental measurement was performed us- ing time-resolved particle image velocimetry (TRPIV) to in- vestigate the spatial topological character of coherent struc- tures in wall-bounded turbulence of polymer ad...An experimental measurement was performed us- ing time-resolved particle image velocimetry (TRPIV) to in- vestigate the spatial topological character of coherent struc- tures in wall-bounded turbulence of polymer additive solu- tion. The fully developed near-wall turbulent flow fields with and without polymer additives at the same Reynolds number were measured by TRPIV in a water channel. The compar- isons of turbulent statistics confirm that due to viscoelastic structure of long-chain polymers, the wall-normal velocity fluctuation and Reynolds shear stress in the near-wall region are suppressed significantly. Furthermore, it is noted that such a behavior of polymers is closely related to the decease of the motion of the second and forth quadrants, i.e., the ejection and sweep events, in the near-wall region. The spa- tial topological mode of coherent structures during bursts has been extracted by the new mu-level criteria based on locally averaged velocity structure function. Although the general shapes of coherent structures are unchanged by polymer additives, the fluctuating velocity, velocity gradient, velocity strain rate and vorticity of coherent structures during burst events are suppressed in the polymer additive solution com- pared with that in water. The results show that due to the polymer additives the occurrence and intensity of coherent structures are suppressed, leading to drag reduction.展开更多
In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wa...In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wall structure, the construction level of reinforced concrete can be continuously improved, the construction quality can be guaranteed, and the construction project can be successfully completed, which is worthy of extensive application and promotion in construction enterprises, thus providing a broader development space for construction enterprises.展开更多
The inter-story drift stiffness considered the semirigidity of beam and column joints connection, and P-Delta second order effect of steel frame parts in the mixed structure is presented in the paper. After considerin...The inter-story drift stiffness considered the semirigidity of beam and column joints connection, and P-Delta second order effect of steel frame parts in the mixed structure is presented in the paper. After considering on the influence of semirigidity between steel beams and steel columns, second order effect of beam-column members for steel frame and structural second order effect, the traditional continuum analytial method used in RC shear-frames wall structure is developed to steel frames-reinforced concrete shear wall mixed structure subject to horizontal load in this paper. A continuum approach, which is suitable for analyzing steel frames-reinforced concrete shear wall mixed structure subject to horizontal load, is presented. The method is relatively simple and more practical. It will be referred to structural design for steel frames-reinforced concrete shear wall mixed structure.展开更多
The analytical micromagnetics and numerical simulations were used to investigate the domain wall structure during the magnetization reversal in nanowires. Micromagnetic analysis shows that the domain wall structure is...The analytical micromagnetics and numerical simulations were used to investigate the domain wall structure during the magnetization reversal in nanowires. Micromagnetic analysis shows that the domain wall structure is mainly determined by the competition between the demagnetization energy and exchange energy. The wall with vortex magnetization structure in cross-section is energetically more favorable for wires with large diameter. With the reduction of diameter the exchange energy increases. At a critical diameter the vortex structure can not be sustained and the transition from vortex wall to transverse wall occurs. The critical diameters for this transition are about 40 nm for Ni wire and 20 nm for Fe wire, respectively. A series of micromagnetic simulations on the cone-shaped wire confirm the analytical results. The simulations also show that during the reversal process the vortex domain wall moves much faster than the transverse one.展开更多
A method of localization is proposed to lower the high order of equations in FEM calcula- tion for the stability of a complex thin-walled structure.The localized analysis enables us to obtain both the upper and lower ...A method of localization is proposed to lower the high order of equations in FEM calcula- tion for the stability of a complex thin-walled structure.The localized analysis enables us to obtain both the upper and lower limits for the bifurcating point in a whole linear elastic structural system,as well as an ap- proximate solution to asymptotic post-buckling problem.Some numerical examples are included.展开更多
Pile foundation bearing-retaining wall combination structure is a new type of support structure developed in recent years.This article focuses on the characteristics,advantages,and application scope of the support str...Pile foundation bearing-retaining wall combination structure is a new type of support structure developed in recent years.This article focuses on the characteristics,advantages,and application scope of the support structure,while combining a variety of algorithms,according to different geological conditions and slope stability,as well as summarizes the pile foundation bearing-retaining wall combination structure force analysis and design methods,taking a high-fill road project in Chongqing as an example.The application of this support structure under special conditions,such as thicker soil layer,steeper sliding surface,weak foundation,and limited slope release conditions,is presented,which illustrates the technical advantages of this support structure and proving that it has several other advantages,including clear force mechanism as well as economic and reasonable structure,thus providing reference for similar projects.展开更多
基金National Science and Technology Support Program of China under Grant No.2011BAJ08B02Natural Science Foundation of Beijing under Grant No.8132016Beijing City University Youth Backbone Talent Training Project under Grant No.PHR201108009
文摘In this study, four 1/5 scaled shaking table tests were conducted to investigate the seismic performance of recycled concrete frame-shear wall structures with different recycled aggregates replacement rates and concealed bracing detail. The four tested structures included one normal concrete model, one recycled coarse aggregate concrete model, and two recycled coarse and fi ne aggregate concrete models with or without concealed bracings inside the shear walls. The dynamic characteristics, dynamic response and failure mode of each model were compared and analyzed. Finite element models were also developed and nonlinear time-history response analysis was conducted. The test and analysis results show that the seismic performance of the recycled coarse aggregate concrete frame-shear wall structure is slightly worse than the normal concrete structure. The seismic resistance capacity of the recycled concrete frame-shear wall structure can be greatly improved by setting up concealed bracings inside the walls. With appropriate design, the recycled coarse aggregate concrete frame-shear wall structure and recycled concrete structure with concealed bracings inside the walls can be applied in buildings.
文摘Efficient methods for incorporating engineering experience into the intelligent generation and optimization of shear wall structures are lacking,hindering intelligent design performance assessment and enhancement.This study introduces an assessment method used in the intelligent design and optimization of shear wall structures that effectively combines mechanical analysis and formulaic encoding of empirical rules.First,the critical information about the structure was extracted through data structuring.Second,an empirical rule assessment method was developed based on the engineer's experience and design standards to complete a preliminary assessment and screening of the structure.Subsequently,an assessment method based on mechanical performance and material consumption was used to compare different structural schemes comprehensively.Finally,the assessment effectiveness was demonstrated using a typical case.Compared to traditional assessment methods,the proposed method is more comprehensive and significantly more efficient,promoting the intelligent transformation of structural design.
基金Project supported by the National Natural Science Foundation of China(Nos.1332006,11272233,11202122,and 11411130150)the National Fundamental Research Program of China(973 Program)(No.2012CB720101)
文摘The relationship between the in the logarithmic law (log-law) region of bursting event and the low/high-speed streak a turbulent boundary layer is investigated. A tomographic time-resolved particle image velocimetry (TRPIV) system is used to measure the instantaneous three-dimensional-three-component (3D-3C) velocity field. The momentum thickness based Reynolds number is about 2 460. The topological information in the log-law region is obtained experimentally. It is found that the existence of the quadrupole topological structure implies a three-pair hairpin-like vortex packet, which is in connection with the low/high-speed streak. An idealized 3D topological model is then proposed to characterize the observed hairpin vortex packet and low/high-speed streak.
基金supported by the National Natural Science Foundation of China(Grant Nos.51079082 and 51679132)the Nature Science Foundation of Shanghai City(Grant No.14ZR1419600)the Research Innovation Projects of 2013 Shanghai Postgraduate(Grant No.20131129)
文摘With the method of separation of variables and the eigenfunction expansion employed, an analytical solution is presented for the radiation and diffraction of a rectangular structure with an opening near a vertical wall in oblique seas, in which the unknown coefficients are determined by the boundary conditions and matching requirement on the interface. The effects of the width of the opening and the angle of incidence on the hydrodynamic characteristics of a rectangular structure with an opening near a vertical wall are mainly studied. The comparisons of the calculation results with wall-present and with wall-absent are also made. The results indicate that the variation trends of the heave added mass and excitation force with wall-present are almost the same as those with wall-absent, and that the peak values in the former case are obviously larger than those in the latter due to the reflection of the vertical wall.
文摘Mixed-type structures combining the advantages of pile constructions(low material consumption and possibility to erect on weak soils)and gravity walls(high bearing capacity and stability,good reliability and durability)are considered and improved.The sphere of application,main peculiarities,and practical technological aspects of these structures’implementation are analyzed.
基金supported by Supported by the Science and Technology Research Program of the Institute of Mountain Hazards and Environment,CAS(IMHE-ZDRW-01)the National Natural Science Foundation of China,China(Grant Numbers:42077275&42271086)the Special Project of Basic Research-Key Project,Yunnan(Grant Number:202301AS070039).
文摘The present work aims to assess earthquake-induced earth-retaining(ER)wall displacement.This study is on the dynamics analysis of various earth-retaining wall designs in hollow precast concrete panels,reinforcement concrete facing panels,and gravity-type earth-retaining walls.The finite element(FE)simulations utilized a 3D plane strain condition to model full-scale ER walls and numerous nonlinear dynamics analyses.The seismic performance of differentmodels,which includes reinforcement concrete panels and gravity-type and hollowprecast concrete ER walls,was simulated and examined using the FE approach.It also displays comparative studies such as stress distribution,deflection of the wall,acceleration across the wall height,lateral wall displacement,lateral wall pressure,and backfill plastic strain.Three components of the created ER walls were found throughout this research procedure.One is a granular reinforcement backfill,while the other is a wall-facing panel and base foundation.The dynamic response effects of varied earth-retaining walls have also been studied.It was discovered that the facing panel of the model significantly impacts the earthquake-induced displacement of ER walls.The proposed analytical model’s validity has been evaluated and compared with the reinforcement concrete facing panels,gravity-type ER wall,scientifically available data,and American Association of State Highway and Transportation Officials(AASHTO)guidelines results based on FE simulation.The results of the observations indicate that the hollow prefabricated concrete ER wall is the most feasible option due to its lower displacement and high-stress distribution compared to the two types.The methodology and results of this study establish standards for future analogous investigations and professionals,particularly in light of the increasing computational capabilities of desktop computers.
文摘Reinforced concrete(RC) load bearing wall is widely used in high-rise and mid-rise buildings. Due to the number of walls in plan and reduction in lateral force portion, this system is not only stronger against earthquakes, but also more economical. The effect of progressive collapse caused by removal of load bearing elements, in various positions in plan and stories of the RC load bearing wall system was evaluated by nonlinear dynamic and static analyses. For this purpose, three-dimensional model of 10-story structure was selected. The analysis results indicated stability, strength and stiffness of the RC load-bearing wall system against progressive collapse. It was observed that the most critical condition for removal of load bearing walls was the instantaneous removal of the surrounding walls located at the corners of the building where the sections of the load bearing elements were changed. In this case, the maximum vertical displacement was limited to 6.3 mm and the structure failed after applying the load of 10 times the axial load bored by removed elements. Comparison between the results of the nonlinear dynamic and static analyses demonstrated that the "load factor" parameter was a reasonable criterion to evaluate the progressive collapse potential of the structure.
文摘BACKGROUND Inferior wall left ventricular aneurysms are rare,they develop after transmural myocardial infarction(MI)and may be associated with poorer prognosis.We present a unique case of a large aneurysm of the inferior wall complicated by ventricular tachycardia(VT)and requiring surgical resection and mitral valve replacement.CASE SUMMARY A 59-year-old male was admitted for VT one month after he had a delayed presentation for an inferior ST-segment elevation MI and was discovered to have a large true inferior wall aneurysm on echocardiography and confirmed on coronary computed tomography(CT)angiography.Due to the sustained VT,concern for aneurysm expansion,and persistent heart failure symptoms,the patient was referred for surgical resection of the aneurysm with patch repair,mitral valve replacement,and automated implantable cardioverter defibrillator insertion with significant improvement in functional and clinical status.CONCLUSION Inferior wall aneurysms are rare and require close monitoring to identify electrical or contractile sequelae.Coronary CT angiography can outline anatomic details and guide surgical intervention to ameliorate life-threatening complications and improve performance status.
基金supported by the National Magnetic Confinement Fusion Science Program of China(Grant Nos.2012GB105000,2011GB101000,2011GB107000,and 2013013GB102000)the National Natural Science Foundation of China(Grant Nos.10725523,10721505,10090212,111005037,and 11205199)
文摘If βN exceeds βNno-wall, the plasma will be unstable because of external kink and resistive wall mode (RWM). In this article, the effect of the passive structure and the toroidal rotation on the RWM stability in the experimental advanced superconducting tokamak (EAST) are simulated with CHEASE and MARS codes. A model using a one-dimensional (1D) surface to present the effect of the passive plate is proved to be credible. The no wall fiN limit is about 3li, and the ideal wall βN limit is about 4.5li on EAST. It is found that the rotation near the q = 2 surface and the plasma edge affects the RWM more.
基金Supported by the Technology Chamber of Henan Province (092300410031)the Education Chamber of Henan Province (2009A150005)
文摘One new coordination polymer with the chemical formula [CoCu2L2·K2·1.5C2H5OH]n(H4L = 2-hydroxy-3-[(E)-({3-[(2-hydroxybenzoyl)amino]propyl}imino)methyl] benzoic acid) has been synthesized based on the slow diffusion method,and characterized by IR spectroscopy,thermalgravimetric and X-ray diffraction analysis.It crystallizes in the monoclinic system,space group P21/n with a = 11.98860(10),b = 24.4279(3),c = 14.9008(2) ,β = 104.7490(10)°,V = 4220.01(8) 3,Z = 2,Mr = 1009.94,Dc = 1.590 g/cm3,F(000) = 2056,μ(MoKα) = 1.649 mm-1,the final R = 0.0411 and wR = 0.1178 for 5920 observed reflections with I 2σ(I).The compound possesses a 2D brick wall structure constructed from trinuclear units.
文摘Tests of hypervelocity projectile impact on double-wall structure were performed with the front wall ranging from 0.5 mm to 2.0 mm thick and different impact velocities. Smooth particle hydrodynamics (SPH) code in LS-DYNA was employed for the simulation of hypervelocity impact on the double-wall structure. By using elementary shock wave theory, the experimental results above are analyzed. The analysis can provide an explanation for the penetration mechanism of hypervelocity projectile impact on double-wall structure about the effect of front wall thickness and impact velocity..
文摘To discuss the structure design and optimization of building curtain wall, the dynamic characteristics of point supported glass curtain wall system are analyzed by the finite element method. The various technologies are made use of, and according to the characteristics of the structure system, the finite element analysis model with steel structure glass plate beam element and shell element as the basic elements is established. Then, the dynamic characteristics are analyzed, and the modal parameters such as inherent frequency and vibration type are identified. The research results show that the node displacement response power spectrum under the load of wind is obtained, which provides the basis for rationally optimizing the structure. Based on the above findings, it is concluded that the optimization design based on finite element model has a wide significance, which is a useful attempt to reduce the blindness of design and has great engineering significance and application value.
基金supported by the National Natural Science Fundation of China (11272233)National Basic Research Program (973 Program) (2012CB720101)2013 Opening Fund of LNM,Institute of Mechanics,Chinese Academy of Sciences
文摘Abstract Experiments were conducted in a water tunnel by tomographic time-resolved particle image velocimetry (Tomo-TRPIV). The Reynolds number Reo is 2 460 on the base of momentum thickness. According to the physical mechanism of the stretch and compression of multi-scale vortex structures in the wall-bounded turbulence, the topological characteristics of turbulence statistics in logarithmic layer were illustrated by local-averaged velocity structure function. During coherent structures bursting, results reveal that the topological structures of velocity gradients, velocity strain rates and vorticities behave as antisymmetric quadrupole modes. A three-layer antisymmetric quadrupole vortex packet confirms that there is a tight relationship between the outer layer and the near-wall layer.
文摘Perhaps the best way to demonstrate the gained improvements in seismic performance of buildings, integrated with IDRIZI infill walls, is to analyse typical building structures subjected to real case earthquake scenarios. This paper presents obtained analytical results for a characteristic 2D frame structure which (besides the self-weight, superimposed dead loads and live loads) is subjected to real earthquake ground motions. This study case treats three story planar RC (reinforced concrete) frame opened on the ground story while its upper stories are infilled with classical masonry walls. The purpose of this study case is to demonstrate "quantitatively" the seismic performance of this frame structure and, more importantly, to estimate the level of seismic response improvements of the frame when at its ground story is utilized IDRIZI infill wall with door opening. The seismic action considered for this study case is a representation of the 1979 Tivari earthquake, Montenegro. Ultimately, this study demonstrates the remarkable benefits the structure gains (in terms of seismic performance and safety) by the use of IDRIZI wall system as a constitutive part of the 2D frame structure.
基金supported by the National Natural Science Foundation of China(11272233)National Key Basic Research and Development Program(2012CB720101)2012 opening subjects of The State Key Laboratory of Nonlinear Mechanics(LNM),Institute of Mechanics,Chinese Academy of Sciences
文摘An experimental measurement was performed us- ing time-resolved particle image velocimetry (TRPIV) to in- vestigate the spatial topological character of coherent struc- tures in wall-bounded turbulence of polymer additive solu- tion. The fully developed near-wall turbulent flow fields with and without polymer additives at the same Reynolds number were measured by TRPIV in a water channel. The compar- isons of turbulent statistics confirm that due to viscoelastic structure of long-chain polymers, the wall-normal velocity fluctuation and Reynolds shear stress in the near-wall region are suppressed significantly. Furthermore, it is noted that such a behavior of polymers is closely related to the decease of the motion of the second and forth quadrants, i.e., the ejection and sweep events, in the near-wall region. The spa- tial topological mode of coherent structures during bursts has been extracted by the new mu-level criteria based on locally averaged velocity structure function. Although the general shapes of coherent structures are unchanged by polymer additives, the fluctuating velocity, velocity gradient, velocity strain rate and vorticity of coherent structures during burst events are suppressed in the polymer additive solution com- pared with that in water. The results show that due to the polymer additives the occurrence and intensity of coherent structures are suppressed, leading to drag reduction.
文摘In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wall structure, the construction level of reinforced concrete can be continuously improved, the construction quality can be guaranteed, and the construction project can be successfully completed, which is worthy of extensive application and promotion in construction enterprises, thus providing a broader development space for construction enterprises.
文摘The inter-story drift stiffness considered the semirigidity of beam and column joints connection, and P-Delta second order effect of steel frame parts in the mixed structure is presented in the paper. After considering on the influence of semirigidity between steel beams and steel columns, second order effect of beam-column members for steel frame and structural second order effect, the traditional continuum analytial method used in RC shear-frames wall structure is developed to steel frames-reinforced concrete shear wall mixed structure subject to horizontal load in this paper. A continuum approach, which is suitable for analyzing steel frames-reinforced concrete shear wall mixed structure subject to horizontal load, is presented. The method is relatively simple and more practical. It will be referred to structural design for steel frames-reinforced concrete shear wall mixed structure.
基金Foundation item: Project(60571043) supported by the National Natural Science Foundation of ChinaProject(04JJ3078) supported by the Natural Science Foundation of Hunan Province, China
文摘The analytical micromagnetics and numerical simulations were used to investigate the domain wall structure during the magnetization reversal in nanowires. Micromagnetic analysis shows that the domain wall structure is mainly determined by the competition between the demagnetization energy and exchange energy. The wall with vortex magnetization structure in cross-section is energetically more favorable for wires with large diameter. With the reduction of diameter the exchange energy increases. At a critical diameter the vortex structure can not be sustained and the transition from vortex wall to transverse wall occurs. The critical diameters for this transition are about 40 nm for Ni wire and 20 nm for Fe wire, respectively. A series of micromagnetic simulations on the cone-shaped wire confirm the analytical results. The simulations also show that during the reversal process the vortex domain wall moves much faster than the transverse one.
基金Project supported by National Natural Science Foundation of China
文摘A method of localization is proposed to lower the high order of equations in FEM calcula- tion for the stability of a complex thin-walled structure.The localized analysis enables us to obtain both the upper and lower limits for the bifurcating point in a whole linear elastic structural system,as well as an ap- proximate solution to asymptotic post-buckling problem.Some numerical examples are included.
基金Youth Project of Science and Technology Research of Chongqing Municipal Education Commission“Research on the Promotion of Pile Foundation Bearing-Retaining Wall Combined Structure Technology”(Project Number:KJQN201905601)Youth Project of Science and Technology Research of Chongqing Education Commission“Research on Construction Monitoring and Risk Warning of Deep Foundation Pit Project Based on BIM+Internet of Things”(Project Number:KJQN201904306)。
文摘Pile foundation bearing-retaining wall combination structure is a new type of support structure developed in recent years.This article focuses on the characteristics,advantages,and application scope of the support structure,while combining a variety of algorithms,according to different geological conditions and slope stability,as well as summarizes the pile foundation bearing-retaining wall combination structure force analysis and design methods,taking a high-fill road project in Chongqing as an example.The application of this support structure under special conditions,such as thicker soil layer,steeper sliding surface,weak foundation,and limited slope release conditions,is presented,which illustrates the technical advantages of this support structure and proving that it has several other advantages,including clear force mechanism as well as economic and reasonable structure,thus providing reference for similar projects.