There are numerous applications, such as Radar, that leverage wideband technology. However, the presence of noise introduces certain limitations and challenges. It is crucial to harness wideband technology for applica...There are numerous applications, such as Radar, that leverage wideband technology. However, the presence of noise introduces certain limitations and challenges. It is crucial to harness wideband technology for applications demanding the rapid and precise transmission of diverse information from one point to another within a short timeframe. The ability to report a signal without tuning within the input bandwidth stands out as one of the advantages of employing a digital wideband receiver. As indicated, a digital wideband receiver plays a pivotal role in achieving high precision and accuracy. The primary distinction between Analog and Digital Instantaneous Frequency Measurement lies in the fact that analog Instantaneous Frequency Measurement (IFM) receivers have traditionally covered extensive input bandwidths, reporting one accurate frequency per short pulse. In the contemporary landscape, digital IFM systems utilize high-sampling-rate Analog-to-Digital Converters (ADC) along with Hilbert transforms to generate two output channels featuring a 90-degree phase shift. This paper explores the improvement of sensitivity in current digital IFM receivers. The optimization efforts target the Hilbert transform and autocorrelations architectures, aiming to refine the system’s ability to report fine frequencies within a noisy wide bandwidth environment, thereby elevating its overall sensitivity.展开更多
An optical lattice clock based on 87Sr is built at National Institute of Metrology (NIM) of China. The systematic frequency shifts of the clock are evaluated with a total uncertainty of 2.3×10-16. To measure it...An optical lattice clock based on 87Sr is built at National Institute of Metrology (NIM) of China. The systematic frequency shifts of the clock are evaluated with a total uncertainty of 2.3×10-16. To measure its absolute frequency with respect to NIM's cesium fountain clock NIM5, the frequency of a flywheel H-maser of NIM5 is transferred to the Sr laboratory through a 50-kin-long fiber. reference frequency of this H-maser, is used for the optical this Sr clock is measured to be 429228004229873.7(1.4)Hz. A fiber optical frequency comb, phase-locked to the frequency measurement. The absolute frequency of展开更多
We report on frequency measurement of the intercombination(5s^2)^1S0–(5s5p)^3P1transition of the four natural isotopes of strontium, including88^Sr(82.58%),87^Sr(7.0%),86^Sr(9.86%), and84^Sr(0.56%). A nar...We report on frequency measurement of the intercombination(5s^2)^1S0–(5s5p)^3P1transition of the four natural isotopes of strontium, including88^Sr(82.58%),87^Sr(7.0%),86^Sr(9.86%), and84^Sr(0.56%). A narrow-linewidth laser that is locked to an ultra-low expansion(ULE) optical cavity with a finesse of 12000 is evaluated at a linewidth of 200 Hz with a fractional frequency drift of 2.8×10^-13 at an integration time of 1 s. The fluorescence collector and detector are specially designed, based on a thermal atomic beam. Using a double-pass acousto-optic modulator(AOM) combined with a fiber and laser power stabilization configuration to detune the laser frequency enables high signal-to-noise ratios and precision saturated spectra to be obtained for the six transition lines, which allows us to determine the transition frequency precisely.The optical frequency is measured using an optical frequency synthesizer referenced to an H maser. Both the statistical values and the final values, including the corrections and uncertainties, are derived for a comparison with the values given in other works.展开更多
This paper reports that two identical external-cavity-diode-laser (ECDL) based spectrometers are constructed at 634nm referencing on the hyperfine B-X transition R(80)8-4 of 127I2. The lasers are stabilized on the...This paper reports that two identical external-cavity-diode-laser (ECDL) based spectrometers are constructed at 634nm referencing on the hyperfine B-X transition R(80)8-4 of 127I2. The lasers are stabilized on the Doppler-free absorption signals using the third-harmonic detection technique. The instability of the stabilized laser is measured to be 2.8 × 10^-12 (after 1000 s) by counting the beat note between the two lasers. The absolute optical frequency of the transition is, for the first time, determined to be 472851936189.5 kHz by using an optical frequency comb referenced on the microwave caesium atomic clock. The uncertainty of the measurement is less than 4.9 kHz.展开更多
A scheme for instantaneous frequency measurement(IFM)using two parallel I/Q modulators based on optical power monitoring is proposed.The amplitude comparison function(ACF)can be constructed to establish the relationsh...A scheme for instantaneous frequency measurement(IFM)using two parallel I/Q modulators based on optical power monitoring is proposed.The amplitude comparison function(ACF)can be constructed to establish the relationship between the frequency of radio frequency(RF)signal and the power ratio of two optical signals output by two I/Q modulators.The frequency of RF signal can be derived by measuring the optical power of the optical signals output by two I/Q modulators.The measurement range and measurement error can be adjusted by controlling the delay amount of the electrical delay line.The feasibility of the scheme is verified,and the corresponding measurement range and measurement error of the system under different delay amounts of the electrical delay line are given.Compared with previous IFM schemes,the structure of this scheme is simple.Polarization devices,a photodetector and an electrical power meter are not used,which reduces the impact of the environmental disturbance on the system and the cost of the system.In simulation,the measurement range can reach 0 GHz-24.5 GHz by adjusting the delay amount of the electrical delay lineτ=20 ps.The measurement error of the scheme is better at low frequency,and the measurement error of low frequency 0 GHz-9.6 GHz can reach-0.1 GHz to+0.05 GHz.展开更多
According to the requirement of multi-parameter time and frequency measurement without frequency normalization,a different frequency synchronization theory is proposed based on Lissajous figure method and the variatio...According to the requirement of multi-parameter time and frequency measurement without frequency normalization,a different frequency synchronization theory is proposed based on Lissajous figure method and the variation lawof Lissajous figure which are used in practice teaching of frequency measurement. The theory can achieve high-precision transmission and comparison of time and frequency and precise locking and tracking of phase and frequency,improve the level of scientific research on time and frequency for postgraduate,and promote practice teaching innovation of time frequency measurement for undergraduate. Utilizing the ratio of horizontal and vertical inflection point of the Lissajous figure,the nominal frequency of the measured signal is precisely calculated.The frequency deviation between the measured frequency and its nominal frequency can be obtained by combining the turning cycle of the Lissajous figure. By observing the phase relationship between the frequency standard signal and the measured signal,the accurate measurement of the frequency is implemented. Experimental results showthat the direct measurement and comparison better than the 10-11 order of magnitude with common frequency source can be finished between any signal frequencies.The frequency measurement method based on the theory has the advantage of simple operation,quick measurement speed,small error,lownoise and high measurement precision. It plays an important role in time synchronization,communications,metrology,scientific research,educational technology practice and equipment and other fields.展开更多
The absolute frequency of 87Rb 5S1/2 (F=2)→5D5/2 (F" = 4) two-photon transition at 778nm is measured in an accuracy of 44kHz. A home-made erbium-doped fiber laser frequency comb with frequency stability of 5.0 ...The absolute frequency of 87Rb 5S1/2 (F=2)→5D5/2 (F" = 4) two-photon transition at 778nm is measured in an accuracy of 44kHz. A home-made erbium-doped fiber laser frequency comb with frequency stability of 5.0 × 10-13@1 s is employed for the light source. By using a periodically poled lithium niobate, the femtosecond pulse operating in 1556 nm is frequency-doubled to 778 nm to obtain the direct two-photon transition spectroscopy of thermal rubidium vapor. Through sweeping the carrier envelope offset frequency (fceo), the 5S1/2 (F=2)→5D5/2 (F" = 4) two-photon transition line is clearly resolved and its absolute frequency is determined via the peak-finding of the fitting curve. After the frequency correction, the measured result agrees well with the previous experiment on this transition. The entire potential candidate of optical frequency standard for system configuration is compact and robust, providing a telecommunication applications.展开更多
We propose and analyze an instantaneous frequency measurement system by using optical power monitoring technique with improved resolution.The primary component adopted in the proposal is a dual-polarization quadrature...We propose and analyze an instantaneous frequency measurement system by using optical power monitoring technique with improved resolution.The primary component adopted in the proposal is a dual-polarization quadrature phase shift keying(DP-QPSK) modulator which is used to modulate the microwave signal that has a designed time delay and phase shifting.The generated optical signal is sent to polarization beam splitter(PBS) in DP-QPSK modulator.Owing to the complementary transmission nature of polarization interference introduced by PBS,the frequency information is converted into the optical power and the relationship between the amplitude comparison function(ACF) and microwave frequency to be measured is established.Thus,the frequency of the microwave signal can be easily measured through monitoring the optical powers of the two output ports of the PBS.Furthermore,by adjusting the direct current(DC) biases of the DP-QPSK modulator instead of changing the electrical delay,the measurement range and resolution can be switched.In this paper,the basic principle of the instantaneous frequency measurement system is derived in detail,and simulation has been performed to investigate the resolution,the measurement range,and the influence of imperfection devices.The proposed scheme is wavelength-independent and its measurement range is switchable,which can avoid the laser wavelength drifting problem and thus greatly increasing the system flexibility.展开更多
The optical frequency comb has been widely used in precision measurement. In this study, a multi-peak fitting approach is first proposed to fit the two-photon transition spectrum which overlaps with the neighboring tr...The optical frequency comb has been widely used in precision measurement. In this study, a multi-peak fitting approach is first proposed to fit the two-photon transition spectrum which overlaps with the neighboring transition in Rb-87. The multi-peak fitting approach is used to eliminate the frequency shift affected by the neighboring transition. With locking the carrier envelope offset frequency at 1/4 repetition frequency, the transition frequency is measured to be 770569132739.9 +/- 5.8 kHz, which agrees well with the previous result recommended by Comite International des Poids et Mesures.展开更多
The present study aims to develop a robust structural damage identification method that can be used for the evaluation of bridge structures. An approach for the structural damage identification based on the measuremen...The present study aims to develop a robust structural damage identification method that can be used for the evaluation of bridge structures. An approach for the structural damage identification based on the measurement of natural frequencies is presented. The structural damage model is assumed to be associated with a reduction of a contribution to the element stiffness matrix equivalent to a scalar reduction of the material modulus. A computational procedure for the direct iteration technique based on the non-linear perturbation theory is proposed to identify structural damage. The presented damage identification technique is applied to the footbridge over the Slunjcica River near Slunj to demonstrate the effectiveness of the proposed approach. Using a limited number of measured natural frequencies, reduction in the stiffness of up to 100% at multiple sites is detected. The results indicate that the proposed approach can be successful in not only predicting the location of damage but also in determining the extent of structural damage.展开更多
A novel photonic-assisted approach to microwave frequency measurement is proposed and experimentally demonstrated. The proposed scheme is based on the frequency-to-power mapping with different transmis- sion responses...A novel photonic-assisted approach to microwave frequency measurement is proposed and experimentally demonstrated. The proposed scheme is based on the frequency-to-power mapping with different transmis- sion responses. A polarizer is used in one output branch of a phase modulator to simultaneously implement phase modulation and intensity modulation. Owing to the complementary nature of the transmission re- sponses and the Mach-Zehnder interferometers (MZIs), this scheme theoretically provides high resolution and tunable measurement range. The measurement errors in the experimental results can be kept within 0.2 GHz over a freauencv ranee from 0.1 to 5.3 GHz.展开更多
We propose and demonstrate a photonic approach to instantaneous frequency measurement with an extended range based on phase modulation. In the measurement system, two optical wavelengths and two dispersion fiber segme...We propose and demonstrate a photonic approach to instantaneous frequency measurement with an extended range based on phase modulation. In the measurement system, two optical wavelengths and two dispersion fiber segments are used to construct the frequency-dependent amplitude comparison functions (ACFs). Several ACFs can be utilized jointly to determine the microwave frequency without ambiguities beyond a monotonic region of the lone conventional ACF. The measurable range of microwave frequency can be extended and the accuracy can be improved by selecting an ACF with a large slope. The experimental results show that the errors are limited within ±140 MHz of a frequency measuremental range from 8 to 20 GHz.展开更多
We propose a novel photonic technique for microwave frequency measurement based on transversal microwave filters with high resolution. Two parallel microwave filters with sine and cosine frequency responses are obtain...We propose a novel photonic technique for microwave frequency measurement based on transversal microwave filters with high resolution. Two parallel microwave filters with sine and cosine frequency responses are obtained by cross gain modulation in a single semiconductor optical amplifier, which introduces two different frequency responses to achieve an amplitude comparison function. We also demonstrate a proof-of-concept experiment. The measurement error is less than ±0.04 GHz for the first band range of 0–3.45 GHz and less than ±0.03 GHz for the second band range of 3.45–5.8 GHz. Our scheme is found to be capable of being extended for larger frequency range measurements using a shorter fiber length.展开更多
We demonstrate a chip-scale scheme of Brillouin instantaneous frequency measurement(IFM) in a CMOS-compatible doped silica waveguide chip. In the chip-scale Brillouin IFM scheme, the frequency-to-power mapping process...We demonstrate a chip-scale scheme of Brillouin instantaneous frequency measurement(IFM) in a CMOS-compatible doped silica waveguide chip. In the chip-scale Brillouin IFM scheme, the frequency-to-power mapping process is achieved by one-shot detection without additional time averaging and implemented by lock-in amplification, which successfully detects the Brillouin gain of the doped silica waveguide chip in the time domain. A Costas frequency modulated signal ranging from 8 GHz to 9 GHz is experimentally measured, and the frequency measurement errors are maintained within 58 MHz.展开更多
A broadband instantaneous multi-frequency measurement system based on chirped pulse compression,which potentially has a sub-megahertz(MHz)accuracy and a hundred-gigahertz(GHz)measurement range,is demonstrated.A signal...A broadband instantaneous multi-frequency measurement system based on chirped pulse compression,which potentially has a sub-megahertz(MHz)accuracy and a hundred-gigahertz(GHz)measurement range,is demonstrated.A signalunder-test(SUT)is converted into a carrier-suppressed double-sideband(CS-DSB)signal,which is then combined with an optical linearly frequency-modulated signal having the sweeping range covering the+1 st-order sideband of the CSDSB signal.With photodetection,low-pass filtering,and pulse compression,accurate frequencies of the SUT are obtained via locating the correlation peaks.In the experiment,single-and multi-frequency measurements with a measurement range from 3 to 18 GHz and a measurement accuracy of<±100 MHz are achieved.展开更多
Although stimulus frequency otoacoustic emissions (SFOAEs) have been used as a non-invasive measure of cochlear mechanics, clinical and experimental application of SFOAEs has been limited by difficulties in accurately...Although stimulus frequency otoacoustic emissions (SFOAEs) have been used as a non-invasive measure of cochlear mechanics, clinical and experimental application of SFOAEs has been limited by difficulties in accurately deriving quantitative information from sound pressure measured in the ear canal. In this study, a novel signal processing method for multicomponent analysis (MCA) was used to measure the amplitude and delay of the SFOAE. This report shows the delay-frequency distribution of the SFOAE measured from the human ear. A low level acoustical suppressor near the probe tone significantly suppressed the SFOAE, strongly indicating that the SFOAE was generated at characteristic frequency locations. Information derived from this method may reveal more details of cochlear mechanics in the human ear.展开更多
A method for super high resolution comparison measurement is proposed in this paper with a comparison between the frequency standards of different nominal frequencies, which is based on phase coincidence detection of ...A method for super high resolution comparison measurement is proposed in this paper with a comparison between the frequency standards of different nominal frequencies, which is based on phase coincidence detection of the two compared signals. It utilizes the regular phase shift characteristics between the signals. The resolution of the measurement approach can reach 10^-13/s at 5 MHz, and the self-calibration resolution can achieve 10^-14/s in the comparison between 10 MHz and 100 MHz, or even can reach 10^-15/s in the comparison between 10 MHz and 190 MHz. This method implies significant progress in the development of the high precision frequency standard comparison technology.展开更多
Femtosecond optical frequency combs correlate the microwave and optical frequencies accurately and coherently.Therefore,any optical frequency in visible to near-infrared region can be directly traced to a microwave fr...Femtosecond optical frequency combs correlate the microwave and optical frequencies accurately and coherently.Therefore,any optical frequency in visible to near-infrared region can be directly traced to a microwave frequency.As a result,the length unit“meter”is directly related to the time unit“second”.This paper validates the capability of the national wavelength standards based on a home-made Er-doped fiber femtosecond optical frequency comb to measure the laser frequencies ranging from visible to near-infrared region.Optical frequency conversion in the femtosecond optical frequency comb is achieved by combining spectral broadening in a highly nonlinear fiber with a single-point frequencydoubling scheme.The signal-to-noise ratio of the beat notes between the femtosecond optical frequency comb and the lasers at 633,698,729,780,1064,and 1542 nm is better than 30 d B.The frequency instability of the above lasers is evaluated by using a hydrogen clock signal with a instability of better than 1×10^(-13)at 1-s averaging time.The measurement is further validated by measuring the absolute optical frequency of an iodine-stabilized 532-nm laser and an acetylenestabilized 1542-nm laser.The results are within the uncertainty range of the international recommended values.Our results demonstrate the accurate optical frequency measurement of lasers at different frequencies using the femtosecond optical frequency comb,which is not only important for the precise and accurate traceability and calibration of the laser frequencies,but also provides technical support for establishing the national wavelength standards based on the femtosecond optical frequency comb.展开更多
In deep space exploration,many engineering and scientific requirements require the accuracy of the measured Doppler frequency to be as high as possible.In our paper,we analyze the possible frequency measurement points...In deep space exploration,many engineering and scientific requirements require the accuracy of the measured Doppler frequency to be as high as possible.In our paper,we analyze the possible frequency measurement points of the third-order phase-locked loop(PLL)and find a new Doppler measurement strategy.Based on this finding,a Doppler frequency measurement algorithm with significantly higher measurement accuracy is obtained.In the actual data processing,compared with the existing engineering software,the accuracy of frequency of 1 second integration is about 5.5 times higher when using the new algorithm.The improved algorithm is simple and easy to implement.This improvement can be easily combined with other improvement methods of PLL,so that the performance of PLL can be further improved.展开更多
In order to measure the range, angle, and Doppler frequency of the target without any synchronization in the bistatic radar, a novel complete parameter estimation method based on separability of a pair of Linear Frequ...In order to measure the range, angle, and Doppler frequency of the target without any synchronization in the bistatic radar, a novel complete parameter estimation method based on separability of a pair of Linear Frequency Modulation (LFM) signal is presented. The Doppler fre-quency is measured by the time difference between two peak positions corresponding to the positive and the negative LFM return signal respectively. Direction Of Departures (DODs) and Direction Of Arrivals (DOAs) of the target are estimated by constructing a special eigenmatrix in which the es-timated angles can be extracted from the eigenvalue or the eigenvector. The target position can be located in the presence of the estimated DODs, DOAs and the signal delay difference between the echo and the directive wave signal in Multiple Input Multiple Output (MIMO) bistatic radar without any synchronization. The correctness and effectiveness of the proposed method are verified by the computer simulation.展开更多
文摘There are numerous applications, such as Radar, that leverage wideband technology. However, the presence of noise introduces certain limitations and challenges. It is crucial to harness wideband technology for applications demanding the rapid and precise transmission of diverse information from one point to another within a short timeframe. The ability to report a signal without tuning within the input bandwidth stands out as one of the advantages of employing a digital wideband receiver. As indicated, a digital wideband receiver plays a pivotal role in achieving high precision and accuracy. The primary distinction between Analog and Digital Instantaneous Frequency Measurement lies in the fact that analog Instantaneous Frequency Measurement (IFM) receivers have traditionally covered extensive input bandwidths, reporting one accurate frequency per short pulse. In the contemporary landscape, digital IFM systems utilize high-sampling-rate Analog-to-Digital Converters (ADC) along with Hilbert transforms to generate two output channels featuring a 90-degree phase shift. This paper explores the improvement of sensitivity in current digital IFM receivers. The optimization efforts target the Hilbert transform and autocorrelations architectures, aiming to refine the system’s ability to report fine frequencies within a noisy wide bandwidth environment, thereby elevating its overall sensitivity.
基金Supported by the National Natural Science Foundation of China under Grant Nos 91336212 and 91436104
文摘An optical lattice clock based on 87Sr is built at National Institute of Metrology (NIM) of China. The systematic frequency shifts of the clock are evaluated with a total uncertainty of 2.3×10-16. To measure its absolute frequency with respect to NIM's cesium fountain clock NIM5, the frequency of a flywheel H-maser of NIM5 is transferred to the Sr laboratory through a 50-kin-long fiber. reference frequency of this H-maser, is used for the optical this Sr clock is measured to be 429228004229873.7(1.4)Hz. A fiber optical frequency comb, phase-locked to the frequency measurement. The absolute frequency of
基金Project supported by the National Natural Science Foundation of China(Grant No.61127901)the Key Project of the Chinese Academy of Sciences(Grant No.KJZD-EW-W02)
文摘We report on frequency measurement of the intercombination(5s^2)^1S0–(5s5p)^3P1transition of the four natural isotopes of strontium, including88^Sr(82.58%),87^Sr(7.0%),86^Sr(9.86%), and84^Sr(0.56%). A narrow-linewidth laser that is locked to an ultra-low expansion(ULE) optical cavity with a finesse of 12000 is evaluated at a linewidth of 200 Hz with a fractional frequency drift of 2.8×10^-13 at an integration time of 1 s. The fluorescence collector and detector are specially designed, based on a thermal atomic beam. Using a double-pass acousto-optic modulator(AOM) combined with a fiber and laser power stabilization configuration to detune the laser frequency enables high signal-to-noise ratios and precision saturated spectra to be obtained for the six transition lines, which allows us to determine the transition frequency precisely.The optical frequency is measured using an optical frequency synthesizer referenced to an H maser. Both the statistical values and the final values, including the corrections and uncertainties, are derived for a comparison with the values given in other works.
基金Project supported by the National Fundamental Research Program of China (Grant Nos 2005CB3724500 and 2006CB921400)the Major Program of National Natural Science Foundation of China (Grant No 60490280)National Natural Science Foundation of China (Grant No 10574005)
文摘This paper reports that two identical external-cavity-diode-laser (ECDL) based spectrometers are constructed at 634nm referencing on the hyperfine B-X transition R(80)8-4 of 127I2. The lasers are stabilized on the Doppler-free absorption signals using the third-harmonic detection technique. The instability of the stabilized laser is measured to be 2.8 × 10^-12 (after 1000 s) by counting the beat note between the two lasers. The absolute optical frequency of the transition is, for the first time, determined to be 472851936189.5 kHz by using an optical frequency comb referenced on the microwave caesium atomic clock. The uncertainty of the measurement is less than 4.9 kHz.
基金the National Key Research and Development Program of China(Grant No.2018YFB1801003)the National Natural Science Foundation of China(Grant Nos.61525501 and 61827817)the Beijing Natural Science Foundation,China(Grant No.4192022).
文摘A scheme for instantaneous frequency measurement(IFM)using two parallel I/Q modulators based on optical power monitoring is proposed.The amplitude comparison function(ACF)can be constructed to establish the relationship between the frequency of radio frequency(RF)signal and the power ratio of two optical signals output by two I/Q modulators.The frequency of RF signal can be derived by measuring the optical power of the optical signals output by two I/Q modulators.The measurement range and measurement error can be adjusted by controlling the delay amount of the electrical delay line.The feasibility of the scheme is verified,and the corresponding measurement range and measurement error of the system under different delay amounts of the electrical delay line are given.Compared with previous IFM schemes,the structure of this scheme is simple.Polarization devices,a photodetector and an electrical power meter are not used,which reduces the impact of the environmental disturbance on the system and the cost of the system.In simulation,the measurement range can reach 0 GHz-24.5 GHz by adjusting the delay amount of the electrical delay lineτ=20 ps.The measurement error of the scheme is better at low frequency,and the measurement error of low frequency 0 GHz-9.6 GHz can reach-0.1 GHz to+0.05 GHz.
基金Supported by the Project of Higher Education Teaching Reform and Practice in Henan Province(2017SJGLX353)the Project of Science and Technology on Electronic Information Control Laboratory,the Science and Technology Innovation Talents in Colleges and Universities of Henan Province(16HASTIT036)+2 种基金the Educational Technology Equipment and Practical Education of Henan Province(GZS028)the National Natural Science Foundation of China(U1304618)the Key Projects of Science And Technology of Henan Province(152102210351)
文摘According to the requirement of multi-parameter time and frequency measurement without frequency normalization,a different frequency synchronization theory is proposed based on Lissajous figure method and the variation lawof Lissajous figure which are used in practice teaching of frequency measurement. The theory can achieve high-precision transmission and comparison of time and frequency and precise locking and tracking of phase and frequency,improve the level of scientific research on time and frequency for postgraduate,and promote practice teaching innovation of time frequency measurement for undergraduate. Utilizing the ratio of horizontal and vertical inflection point of the Lissajous figure,the nominal frequency of the measured signal is precisely calculated.The frequency deviation between the measured frequency and its nominal frequency can be obtained by combining the turning cycle of the Lissajous figure. By observing the phase relationship between the frequency standard signal and the measured signal,the accurate measurement of the frequency is implemented. Experimental results showthat the direct measurement and comparison better than the 10-11 order of magnitude with common frequency source can be finished between any signal frequencies.The frequency measurement method based on the theory has the advantage of simple operation,quick measurement speed,small error,lownoise and high measurement precision. It plays an important role in time synchronization,communications,metrology,scientific research,educational technology practice and equipment and other fields.
基金Supported by the National Natural Science Foundation of China under Grant Nos 61405002,91336103,10934010,61535001 and 61078026
文摘The absolute frequency of 87Rb 5S1/2 (F=2)→5D5/2 (F" = 4) two-photon transition at 778nm is measured in an accuracy of 44kHz. A home-made erbium-doped fiber laser frequency comb with frequency stability of 5.0 × 10-13@1 s is employed for the light source. By using a periodically poled lithium niobate, the femtosecond pulse operating in 1556 nm is frequency-doubled to 778 nm to obtain the direct two-photon transition spectroscopy of thermal rubidium vapor. Through sweeping the carrier envelope offset frequency (fceo), the 5S1/2 (F=2)→5D5/2 (F" = 4) two-photon transition line is clearly resolved and its absolute frequency is determined via the peak-finding of the fitting curve. After the frequency correction, the measured result agrees well with the previous experiment on this transition. The entire potential candidate of optical frequency standard for system configuration is compact and robust, providing a telecommunication applications.
基金Project supported by the National Natural Science Foundation of China(Grant No.61801017,U2006217,62005011,and 61620106014)Beijing Municipal Natural Science Foundation(Grant No.4212009)the Fundamental Research Funds for the Central Universities(Grant No.2020JBM010)。
文摘We propose and analyze an instantaneous frequency measurement system by using optical power monitoring technique with improved resolution.The primary component adopted in the proposal is a dual-polarization quadrature phase shift keying(DP-QPSK) modulator which is used to modulate the microwave signal that has a designed time delay and phase shifting.The generated optical signal is sent to polarization beam splitter(PBS) in DP-QPSK modulator.Owing to the complementary transmission nature of polarization interference introduced by PBS,the frequency information is converted into the optical power and the relationship between the amplitude comparison function(ACF) and microwave frequency to be measured is established.Thus,the frequency of the microwave signal can be easily measured through monitoring the optical powers of the two output ports of the PBS.Furthermore,by adjusting the direct current(DC) biases of the DP-QPSK modulator instead of changing the electrical delay,the measurement range and resolution can be switched.In this paper,the basic principle of the instantaneous frequency measurement system is derived in detail,and simulation has been performed to investigate the resolution,the measurement range,and the influence of imperfection devices.The proposed scheme is wavelength-independent and its measurement range is switchable,which can avoid the laser wavelength drifting problem and thus greatly increasing the system flexibility.
基金Supported by the National Natural Science Foundation of China under Grant Nos 91336103,10934010 and 61078026
文摘The optical frequency comb has been widely used in precision measurement. In this study, a multi-peak fitting approach is first proposed to fit the two-photon transition spectrum which overlaps with the neighboring transition in Rb-87. The multi-peak fitting approach is used to eliminate the frequency shift affected by the neighboring transition. With locking the carrier envelope offset frequency at 1/4 repetition frequency, the transition frequency is measured to be 770569132739.9 +/- 5.8 kHz, which agrees well with the previous result recommended by Comite International des Poids et Mesures.
文摘The present study aims to develop a robust structural damage identification method that can be used for the evaluation of bridge structures. An approach for the structural damage identification based on the measurement of natural frequencies is presented. The structural damage model is assumed to be associated with a reduction of a contribution to the element stiffness matrix equivalent to a scalar reduction of the material modulus. A computational procedure for the direct iteration technique based on the non-linear perturbation theory is proposed to identify structural damage. The presented damage identification technique is applied to the footbridge over the Slunjcica River near Slunj to demonstrate the effectiveness of the proposed approach. Using a limited number of measured natural frequencies, reduction in the stiffness of up to 100% at multiple sites is detected. The results indicate that the proposed approach can be successful in not only predicting the location of damage but also in determining the extent of structural damage.
基金supported by the National "973" Program of China(No.2012CB315705)the National "863" Program of China(No.2011AA010306)+2 种基金the National Natural Science Foundation of China(Nos.61107058,61120106001,60932004,61001121,and 60837004)the Beijing Excellent Doctoral Thesis Project(No.YB20101001301)the Cooperation Project between the Province and Ministries(No.2011A090200025)
文摘A novel photonic-assisted approach to microwave frequency measurement is proposed and experimentally demonstrated. The proposed scheme is based on the frequency-to-power mapping with different transmis- sion responses. A polarizer is used in one output branch of a phase modulator to simultaneously implement phase modulation and intensity modulation. Owing to the complementary nature of the transmission re- sponses and the Mach-Zehnder interferometers (MZIs), this scheme theoretically provides high resolution and tunable measurement range. The measurement errors in the experimental results can be kept within 0.2 GHz over a freauencv ranee from 0.1 to 5.3 GHz.
基金supported by the National Natural Science Foundation of China(No.60807015)the National"863"Program of China(No.2012AA040406)+1 种基金the Natural Science Foundation of Liaoning Province(No.20102020)the Fundamental Research Funds for the Central Universities
文摘We propose and demonstrate a photonic approach to instantaneous frequency measurement with an extended range based on phase modulation. In the measurement system, two optical wavelengths and two dispersion fiber segments are used to construct the frequency-dependent amplitude comparison functions (ACFs). Several ACFs can be utilized jointly to determine the microwave frequency without ambiguities beyond a monotonic region of the lone conventional ACF. The measurable range of microwave frequency can be extended and the accuracy can be improved by selecting an ACF with a large slope. The experimental results show that the errors are limited within ±140 MHz of a frequency measuremental range from 8 to 20 GHz.
基金supported by the National Basic Research Program of China (No. 2006CB302805)the National Natural Science Foundation of China (No.60901006)the Program for New Century Excellent Talents of the Ministry of Education of China (No.NCET-04-0715)
文摘We propose a novel photonic technique for microwave frequency measurement based on transversal microwave filters with high resolution. Two parallel microwave filters with sine and cosine frequency responses are obtained by cross gain modulation in a single semiconductor optical amplifier, which introduces two different frequency responses to achieve an amplitude comparison function. We also demonstrate a proof-of-concept experiment. The measurement error is less than ±0.04 GHz for the first band range of 0–3.45 GHz and less than ±0.03 GHz for the second band range of 3.45–5.8 GHz. Our scheme is found to be capable of being extended for larger frequency range measurements using a shorter fiber length.
基金This work was supported by the National Key Research and Development Program of China(No.2019YFB2203700)the National Natural Science Foundation of China(No.61822508)。
文摘We demonstrate a chip-scale scheme of Brillouin instantaneous frequency measurement(IFM) in a CMOS-compatible doped silica waveguide chip. In the chip-scale Brillouin IFM scheme, the frequency-to-power mapping process is achieved by one-shot detection without additional time averaging and implemented by lock-in amplification, which successfully detects the Brillouin gain of the doped silica waveguide chip in the time domain. A Costas frequency modulated signal ranging from 8 GHz to 9 GHz is experimentally measured, and the frequency measurement errors are maintained within 58 MHz.
基金supported in part by the Postgraduate Research and Practice Innovation Program of Jiangsu Province(No.KYLX16_0367)the National Natural Science Foundation of China(Nos.62071226 and 61971372)+1 种基金the Hong Kong Scholar Program(No.G-YZ2S)HK RGC GRF(No.15200718)。
文摘A broadband instantaneous multi-frequency measurement system based on chirped pulse compression,which potentially has a sub-megahertz(MHz)accuracy and a hundred-gigahertz(GHz)measurement range,is demonstrated.A signalunder-test(SUT)is converted into a carrier-suppressed double-sideband(CS-DSB)signal,which is then combined with an optical linearly frequency-modulated signal having the sweeping range covering the+1 st-order sideband of the CSDSB signal.With photodetection,low-pass filtering,and pulse compression,accurate frequencies of the SUT are obtained via locating the correlation peaks.In the experiment,single-and multi-frequency measurements with a measurement range from 3 to 18 GHz and a measurement accuracy of<±100 MHz are achieved.
基金Supported in part by research grants from the National Institute of Deafness and Other Communication Disorders(R01 DC 00141 and R03 DC033642)the National Institutes of Health+2 种基金the Research Fund of the American Otological Societythe Medical Research Foundation of OregonVA RR&D Center Grant RCTR-597-0160,Portland,VAMC
文摘Although stimulus frequency otoacoustic emissions (SFOAEs) have been used as a non-invasive measure of cochlear mechanics, clinical and experimental application of SFOAEs has been limited by difficulties in accurately deriving quantitative information from sound pressure measured in the ear canal. In this study, a novel signal processing method for multicomponent analysis (MCA) was used to measure the amplitude and delay of the SFOAE. This report shows the delay-frequency distribution of the SFOAE measured from the human ear. A low level acoustical suppressor near the probe tone significantly suppressed the SFOAE, strongly indicating that the SFOAE was generated at characteristic frequency locations. Information derived from this method may reveal more details of cochlear mechanics in the human ear.
基金supported by the National Natural Science Foundation of China (Grant Nos.60772135 and 10978017)the Open Fund of Key Laboratory of Precision Navigation and Technology,National Time Service Center,Chinese Academy of Sciences (Grant No.2009PNTT10)the Fundamental Research Funds for the Central Universities,China (Grant No.JY10000905015)
文摘A method for super high resolution comparison measurement is proposed in this paper with a comparison between the frequency standards of different nominal frequencies, which is based on phase coincidence detection of the two compared signals. It utilizes the regular phase shift characteristics between the signals. The resolution of the measurement approach can reach 10^-13/s at 5 MHz, and the self-calibration resolution can achieve 10^-14/s in the comparison between 10 MHz and 100 MHz, or even can reach 10^-15/s in the comparison between 10 MHz and 190 MHz. This method implies significant progress in the development of the high precision frequency standard comparison technology.
基金the National Key Research and Development Program of China(Grant No.2016YFF0200204)。
文摘Femtosecond optical frequency combs correlate the microwave and optical frequencies accurately and coherently.Therefore,any optical frequency in visible to near-infrared region can be directly traced to a microwave frequency.As a result,the length unit“meter”is directly related to the time unit“second”.This paper validates the capability of the national wavelength standards based on a home-made Er-doped fiber femtosecond optical frequency comb to measure the laser frequencies ranging from visible to near-infrared region.Optical frequency conversion in the femtosecond optical frequency comb is achieved by combining spectral broadening in a highly nonlinear fiber with a single-point frequencydoubling scheme.The signal-to-noise ratio of the beat notes between the femtosecond optical frequency comb and the lasers at 633,698,729,780,1064,and 1542 nm is better than 30 d B.The frequency instability of the above lasers is evaluated by using a hydrogen clock signal with a instability of better than 1×10^(-13)at 1-s averaging time.The measurement is further validated by measuring the absolute optical frequency of an iodine-stabilized 532-nm laser and an acetylenestabilized 1542-nm laser.The results are within the uncertainty range of the international recommended values.Our results demonstrate the accurate optical frequency measurement of lasers at different frequencies using the femtosecond optical frequency comb,which is not only important for the precise and accurate traceability and calibration of the laser frequencies,but also provides technical support for establishing the national wavelength standards based on the femtosecond optical frequency comb.
基金supported by the National Natural Science Foundation of China(Grant Nos.11773060,11973074,U1831137 and 11703070)National Key Basic Research and Development Program(2018YFA0404702)+1 种基金Shanghai Key Laboratory of Space Navigation and Positioning(3912DZ227330001)the Key Laboratory for Radio Astronomy of CAS。
文摘In deep space exploration,many engineering and scientific requirements require the accuracy of the measured Doppler frequency to be as high as possible.In our paper,we analyze the possible frequency measurement points of the third-order phase-locked loop(PLL)and find a new Doppler measurement strategy.Based on this finding,a Doppler frequency measurement algorithm with significantly higher measurement accuracy is obtained.In the actual data processing,compared with the existing engineering software,the accuracy of frequency of 1 second integration is about 5.5 times higher when using the new algorithm.The improved algorithm is simple and easy to implement.This improvement can be easily combined with other improvement methods of PLL,so that the performance of PLL can be further improved.
基金Supported by National Natural Science Foundation of China (No. 60601016)
文摘In order to measure the range, angle, and Doppler frequency of the target without any synchronization in the bistatic radar, a novel complete parameter estimation method based on separability of a pair of Linear Frequency Modulation (LFM) signal is presented. The Doppler fre-quency is measured by the time difference between two peak positions corresponding to the positive and the negative LFM return signal respectively. Direction Of Departures (DODs) and Direction Of Arrivals (DOAs) of the target are estimated by constructing a special eigenmatrix in which the es-timated angles can be extracted from the eigenvalue or the eigenvector. The target position can be located in the presence of the estimated DODs, DOAs and the signal delay difference between the echo and the directive wave signal in Multiple Input Multiple Output (MIMO) bistatic radar without any synchronization. The correctness and effectiveness of the proposed method are verified by the computer simulation.