Monitoring actual performance of ground source heat pump system using GPRS-based data transmission: A case analysis in Tangshan 被引量:2
1
作者 杜红普 孔祥飞 +1 位作者 李敏 齐承英 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第4期1554-1562,共9页
The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is... The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability. 展开更多
关键词 ground source heat pump monitoring operation performance
下载PDF
Application of Ground Source Heat Pump to a Supermarket in Portugal
2
作者 Joao Garcia Luis Coelho +3 位作者 Rita Cerdeira Burkhard Sanner Philippe Lentz Nicolas Frechin 《Journal of Civil Engineering and Architecture》 2011年第3期241-247,共7页
The objective of the present paper is to describe a technical and economical visibility study of the application of ground source heat pumps (GSHP) in a supermarket in Portugal. The study was developed under the Eur... The objective of the present paper is to describe a technical and economical visibility study of the application of ground source heat pumps (GSHP) in a supermarket in Portugal. The study was developed under the European project "Integration of Geothermal Energy Into Industrial Application - IGEIA", project number EIE 06/001, supported by the Intelligent Energy for Europe, IEE, of EACI, European Commission. In general for supermarkets installed in single buildings, the building envelope has higher rates of envelope areas per indoor air volume. In Portugal this fact produces high need of heating during the winter season and high cooling needs during the summer season. Inside the building there are strong internal heat loads produced by high densities of lights and equipments. However these internal loads are not distributed uniformly. There are some areas with high production of heat but there are others with production of cooling. Therefore the acclimatization of this kind of buildings is not so easy and the balance of heating and cooling needs is depending of different parameters which should be well evaluated. The energy consummation of the cold display cases and deep freezers in market area and storage is also very high. The different energy needs could be studied in an integrated way and could be partially satisfied by geothermal energy using ground source heat pumps. At the same time the boreholes could be used as an energy reservoir increasing the efficiency of whole system. Four different climatic zones in Portugal were selected, (north coast, interior north, south coast and interior south) using the same system. The results of the study show that the all energy needs can by partially satisfied by geothermal energy but they need to be integrated to increase the global efficiency. The paper shows that the geothermal energy can be an attractive application for the supermarkets in Portugal if the energy solution is studied in an integrated way and if it is also considered as a cost the emissions of CO2 avoid by the new system. 展开更多
关键词 Geothermal energy ground source heat pump high efficiency
下载PDF
Evaluation of suitability area by ground source heat pump system in Baotou plain
3
作者 WANG Chunpeng WANG Qinghua +2 位作者 FENG Lei FENG Ye CHENG Sanhuan 《Global Geology》 2014年第3期176-181,共6页
According to the elements of hydrogeological conditions,lithology,stratigraphic thermal physical parameters,construction technology and economic rational elements,the evaluation system of ground source heat pump( GSHP... According to the elements of hydrogeological conditions,lithology,stratigraphic thermal physical parameters,construction technology and economic rational elements,the evaluation system of ground source heat pump( GSHP) were established in Baotou plain. The factor weights were determined by using analytic hierarchy process,and the comprehensive element method was selected to evaluate the region suitability of GSHP system. The results show that the suitable area is 559. 63 km2 for utilizing GSHP in the studied area,accounting for 62. 58% of the total area; while the unsuitable area is 334. 60 km2,accounting for37.42%. The evaluating results can provide not only a scientific basis for development and utilization rationally of shallow geothermal heat in Baotou,but also offer an important reference to the other areas. 展开更多
关键词 Baotou plain ground source heat pump suitability area evaluation: analytic hierarchy process comprehensive element method
下载PDF
Possibilities of Reducing Energy Consumption by Optimization of Ground Source Heat Pump Systems in Babylon, Iraq
4
作者 Jenny Lindblom Nadhir Al-Ansari Qais Al-Madhlom 《Engineering(科研)》 2016年第3期130-139,共10页
Iraq is located in the Middle East with an area that reaches 437,072 km2 and a population of about 36 million. This country is suffering from severe electricity shortage problems which are expected to increase with ti... Iraq is located in the Middle East with an area that reaches 437,072 km2 and a population of about 36 million. This country is suffering from severe electricity shortage problems which are expected to increase with time. In this research, an attempt is made to minimize this problem by combining the borehole thermal energy storage (BTES) with a heat pump, the indoor temperature of a residential building or other facility may be increased or reduced beyond the temperature interval of the heat carrier fluid. Due to the relatively high ground temperature in Middle Eastern countries, the seasonal thermal energy storages (STES) and ground source heat pump (GSHP) systems have a remarkable potential, partly because the reduced thermal losses from the underground storage and the expected high COP (ratio of thermal energy gain to required driving energy (electricity)) of a heat pump, partly because of the potential for using STES directly for heating and cooling. In this research, groundwater conditions of Babylon city in Iraq were investigated to evaluate the possibility of using GSHP to reduce energy consumption. It is believed that such system will reduce consumed energy by about 60%. 展开更多
关键词 ground source heat pump Seasonal Thermal Energy Storages Energy Saving BABYLON Iraq
下载PDF
Research on ground heat exchanger of Ground Source Heat Pump technique
5
作者 LIUDong-sheng SUNYou-hong GAOKe WUXiao-hang 《Journal of Geoscientific Research in Northeast Asia》 2004年第2期196-199,共4页
Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its patterns are discussed. Software is helpful to d... Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its patterns are discussed. Software is helpful to design ground heat exchanger. A project of Chinese Ground Source Heat Pump is introduced and its market is more and more extensive. 展开更多
关键词 ground source heat pump ground heat exchanger SOFTWARE DESIGN
下载PDF
Zoning operation of energy piles to alleviate the soil thermal imbalance of ground source heat pump systems 被引量:2
6
作者 Tian You Weitao Zeng 《Energy and Built Environment》 2023年第1期57-63,共7页
Energy piles have attracted increasing interest for application in ground source heat pumps,because it is environment-friendly,energy-efficient,and without additional drilling cost.However,when there is a large dif-fe... Energy piles have attracted increasing interest for application in ground source heat pumps,because it is environment-friendly,energy-efficient,and without additional drilling cost.However,when there is a large dif-ference between the heating and cooling loads,the system will suffer from a soil thermal imbalance which may further decline the system performance and even cause a system failure.A hybrid ground source heat pump sys-tem that integrates auxiliary equipment can solve the problem,however,it needs additional investment and a complicated control strategy.In this paper,the zoning operation of energy piles can effectively improve the tem-perature recovery ability of soil in the energy pile group and thus alleviate the soil thermal imbalance.Specifically,a heating-dominated residential building in Beijing is selected for a case study,with 144 energy piles arranged in a 12×12 layout.An analytical model of the spiral-coil energy pile group with seepage will be adopted,which can consider the groundwater flow,the geometry of spiral coils,and the thermal interaction among different energy piles,achieving high calculation accuracy and fast calculation speed.Based on this analytical energy pile model,a system model will be built to investigate the system performance influenced by different zoning operation strategies.Results show that intensive heat injection into the center of the pile group(Strategy 2 and Strategy 3)or heat extraction from the outer layer of the pile group(Strategy 4)can relieve the cold accumulation.Strategy 2 can relieve the outlet temperature decline from 5.54℃ to 4.46℃ and improve the heating COP from 3.297 to 3.423 compared to the conventional full operation strategy.Although the annual heat pump COP of Strategy 2 is a little lower than that of conventional full operation strategy,Strategy 2 has the shortest unmet heating or cooling time.Therefore,the proposed zoning operation strategy can achieve good system efficiency and excellent system reliability compared to the conventional strategy. 展开更多
关键词 ground source heat pump Energy pile Zoning operation Soil thermal imbalance Cold accumulation
原文传递
Prediction and parametric analysis of 3D borehole and total internal thermal resistance of single U-tube borehole heat exchanger for ground source heat pumps
7
作者 Kun Zhou Jinfeng Mao +2 位作者 Yong Li Hua Zhang Zhongkai Deng 《Energy and Built Environment》 2023年第2期179-194,共16页
The borehole and total internal thermal resistance are both significant parameters in evaluating the thermal performance of the ground source heat pump.This study aimed to obtain the accurate correlation of the 3D bor... The borehole and total internal thermal resistance are both significant parameters in evaluating the thermal performance of the ground source heat pump.This study aimed to obtain the accurate correlation of the 3D borehole and total internal thermal resistance(R_(b,3D)and R_(a,3D))and analyze the impacts of parameters on the R_(b,3D)and R_(a,3D).Firstly,eight parameters affecting the R_(b,3D)and R_(a,3D),including the borehole diameter,pipe diameter,pipe-pipe distance,borehole depth,soil thermal conductivity,grout thermal conductivity,pipe thermal conductivity,and fluid velocity inside the pipe,were considered and an L-54 design matrix was generated.Then,the 3D numerical model,coupling with the four-resistance model,was proposed to calculate R_(b,3D)and R_(a,3D)for each case.After that,the response surface methodology was employed to obtain and verify the correlation of R_(b,3D)and R_(a,3D),which were compared with the existing resistance calculation methods.Lastly,analysis of variance was carried out to reveal parameters that have statistically significant impacts on the R_(b,3D)and R_(a,3D).Results show that the rationality and accuracy of the correlation of R_(b,3D)and R_(a,3D)can be verified by the determination coefficient and P value of regression model,as well as the P value of lack-of-fit.The existing resistance calculation methods are more or less inaccurate and the discrepancies in some cases can be up to 86.74%and 111.35%for the borehole and total internal thermal resistance.The pipe and grout thermal conductivity,pipe and borehole diameter,and the pipe-pipe distance can be seen as the significant contributory factors to the variation of R_(b,3D)and R_(a,3D). 展开更多
关键词 ground source heat pump Borehole thermal resistance Total internal thermal resistance Four-resistance model Response surface methodology
原文传递
Application and development of ground source heat pump technology in China 被引量:7
8
作者 Chaofan Song Yang Li +3 位作者 Taha Rajeh Ling Ma Jun Zhao Wenjia Li 《Protection and Control of Modern Power Systems》 2021年第1期215-232,共18页
Ground source heat pumps (GSHPs) are one of the renewable energy technologies with features of high efficiency, energy saving, economic feasibility and environmental protection. In China, GSHPs have been widely used f... Ground source heat pumps (GSHPs) are one of the renewable energy technologies with features of high efficiency, energy saving, economic feasibility and environmental protection. In China, GSHPs have been widely used for building heating and cooling in recent years, and have shown great potential for future energy development. This paper summarizes the classification, development history, and use status of shallow GSHPs. Several typical engineering cases of GSHP technology are also specified and analyzed. Finally, promising development trends and some advanced technologies are illustrated. 展开更多
关键词 Shallow geothermal energy ground source heat pump Case analysis
原文传递
The Application of the Ground Source and Air-to-Water Heat Pumps in Cold Climate Areas 被引量:3
9
作者 Kaspar Tennokese Teet-Andrus Koiv +1 位作者 Alo Mikola Villu Vares 《Smart Grid and Renewable Energy》 2013年第7期473-481,共9页
This article gives an overview of using the ground source heat pump (GSHP) and air-to-water heat pump (A&WHP) in cold climate areas for heating and for domestic hot water production of buildings. Computer simulati... This article gives an overview of using the ground source heat pump (GSHP) and air-to-water heat pump (A&WHP) in cold climate areas for heating and for domestic hot water production of buildings. Computer simulation and analysis were carried out for a typical detached house, with 200 m2 of living area, the heat demand of 9 kW and the average heat demand for DHW production of 1 kW. In heating period the average Coefficient of Performance (COP) of the A&WHP is considerably lower than COP of the GSHP. 展开更多
关键词 ground source heat pump Air-Water heat pump heat Requirement COP
下载PDF
Thermal Efficiency Optimization of a Ground Source Heat Pump System by Assistant Preheating/Precooling: A Case Study on a Heating-Load Dominated Building
10
作者 LUO Jin ZHANG Qi +1 位作者 PRIESS Anna ROHN Joachim 《Journal of Thermal Science》 SCIE EI CAS CSCD 2022年第6期1948-1958,共11页
Operation strategies of Ground Source Heat Pump System(GSHPS) such as continuous or intermittent approaches have been extensively studied. In this work, a novel strategy was proposed to maximize the energy efficiency ... Operation strategies of Ground Source Heat Pump System(GSHPS) such as continuous or intermittent approaches have been extensively studied. In this work, a novel strategy was proposed to maximize the energy efficiency of GSHPS. In this approach, the buildings was first air-conditioned by the preheating/precooling mode and the rest thermal load was covered by the heat pump(HP) mode. The system performance can then be optimized by considering the combination of these two operating modes. A case study was made to examine the thermal performance of a GSHPS installed in Nuremberg, Germany. Thermal performance of the HP and the preheating/precooling operating modes was examined. The system was optimized by deploying the assistant preheating/precooling approach and over one-year period monitoring showed that the seasonal Coefficient of Performance(COP) of the GSHPS was 4.12 in winter and 5.01 in summer. These COP values are higher than that of the conventional GSHPS. Thus, this proposed strategy could be an efficient way to improve the thermal performance of GSHPS. 展开更多
关键词 ground source heat pump system ground-air heat exchanger ground temperature response preheating and precooling
原文传递
Arrangement Strategy of Ground Heat Exchanger with Groundwater 被引量:4
11
作者 李太禄 朱家玲 张伟 《Transactions of Tianjin University》 EI CAS 2012年第4期291-297,共7页
The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat t... The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat transfer of four GHEs was carried out in 2010.Results indicate that the velocity field is disturbed by GHEs.The optimal orientation strategy of side pipe is that the upward pipe is located upstream and the downward pipe downstream.The space between GHEs should be appropriately adjusted,depending on the direction and flow velocity.Groups of GHEs should be installed perpendicular to the mainstream in a single row,but if the acreage does not meet the requirements,GHEs should be installed in staggered multiple rows.Fewer GHEs parallel to the mainstream strengthen the heat transfer.Moreover,numerical results agree well with the test data,with the maximum relative error being less than 7.7%. 展开更多
关键词 ground source heat pump ground heat exchanger groundWATER GEOTHERMICS
下载PDF
Numerical Simulation of Heat Transfer Characteristics of Horizontal Ground Heat Exchanger in Frozen Soil Layer 被引量:2
12
作者 王华军 赵军 《Transactions of Tianjin University》 EI CAS 2007年第3期200-204,共5页
A simplified numerical model of heat transfer characteristics of horizontal ground heat exchanger (GHE) in the frozen soil layer is presented and the steady-state distribution of temperature field is simulated. Numeri... A simplified numerical model of heat transfer characteristics of horizontal ground heat exchanger (GHE) in the frozen soil layer is presented and the steady-state distribution of temperature field is simulated. Numerical results show that the frozen depth mainly depends on the soil′s moisture content and ambient temperature. The heat transfer loss of horizontal GHE tends to grow with the increase of the soil′s moisture content and the decrease of ambient temperature. Backfilled materials with optimal thermal conductivity can reduce the thermal loss effectively in the frozen soil. The applicability of the Chinese national standard “Technical Code for Ground Source Heat Pump (GB 50366-2005)” is verified. For a ground source heat pump project, the feasible layout of horizontal GHE should be determined based on the integration of the soil′s structure, backfilled materials, weather data, and economic analysis. 展开更多
关键词 ground source heat pump horizontal ground heat exchanger frozen soil layer heat transfer
下载PDF
Thermal Analysis of the Ground Properties with a Single Borehole Heat Exchanger
13
作者 王尧萍 周亚素 WU Shen-yi 《Journal of Donghua University(English Edition)》 EI CAS 2010年第5期610-613,共4页
The effect of ground properties with heat conduction between soil and ground loop heat exchangers(GLHEs)has been analyzed.A finite line source model proposed by Cui,Yang,and Fang is used.Far field radius is defined.Th... The effect of ground properties with heat conduction between soil and ground loop heat exchangers(GLHEs)has been analyzed.A finite line source model proposed by Cui,Yang,and Fang is used.Far field radius is defined.The analyses for a 1.5m borehole line source in three kinds of soil conditions:damp and breeze(D.B.),damp and heavy(D.H.),and saturated and heavy(S.H.)are carried out.The results of the comparisons show that in the condition of continuous operation,the variation of the far field radius is related to soil thermal conductivity.The rate of heat transfer will decrease after long time operation.And then soil condition will not influence the far field radius obviously. 展开更多
关键词 ground source heat pump finite line source model far field radius
下载PDF
Thermal Response Test by Improved Test Rig with Heating or Cooling Soil 被引量:1
14
作者 付文成 朱家玲 张伟 《Transactions of Tianjin University》 EI CAS 2014年第1期15-20,共6页
An improved test rig providing both the heat and cold source was used to perform thermal response test (TRT), and the line source model was used for data analysis. The principle of determining the temperature differ... An improved test rig providing both the heat and cold source was used to perform thermal response test (TRT), and the line source model was used for data analysis. The principle of determining the temperature difference between the inlet and outlet of test well can keep the heating or cooling rate constant, along with a reduced size of test rig. Among the influencial factors of the line source model, the temperature difference was determined as the most important, which agreed with the test results. When the gravel was taken as the backfill material, the soil thermal conductivities of heating and cooling at the test place were 1.883 W/(m&#183;K) and 1.754 W/(m&#183;K), respectively, and the deviation of TRT between heating and cooling soil was 6.8%. In the case of fine sand, the thermal conductivities of heating and cooling were 1.541 W/(m&#183;K) and 1.486 W/(m&#183;K), respectively, and the corresponding deviation was 6%. It was also concluded that different velocities of water had less influence on TRT than the temperature difference. 展开更多
关键词 ground source heat pump thermal response test thermal conductivity backfill material
下载PDF
UTES (Underground Thermal Energy Storage)---Applications and Market Development in Sweden
15
作者 Olof Andersson Jonas Ekkestubbe Anna Ekdahl 《Journal of Energy and Power Engineering》 2013年第4期669-678,共10页
The market for shallow geothermal solutions has been continuously growing in Sweden and is recognized as a cost effective and environmental sound way for space heating. In later years, UTES (underground thermal energ... The market for shallow geothermal solutions has been continuously growing in Sweden and is recognized as a cost effective and environmental sound way for space heating. In later years, UTES (underground thermal energy storage) systems have become fTequently installed for combined heating and cooling of commercial and institutional buildings. After 20 years, operational experiences of these systems are proved to be energy efficient, technically safe and profitable. In this paper, the current statistics of UTES applications are given as well as market trends and technical development. The goal is to encourage designers and installers in other counties to use this promising technology. 展开更多
关键词 Shallow geothermal energy storage ground source heat pumps underground thermal energy storage.
下载PDF
Numerical and experimental evaluation on methods for parameter identification of thermal response tests 被引量:3
16
作者 王沣浩 冯琛琛 +1 位作者 颜亮 王新轲 《Journal of Central South University》 SCIE EI CAS 2012年第3期816-823,共8页
Several parameter identification methods of thermal response test were evaluated through numerical and experimental study.A three-dimensional finite-volume numerical model was established under the assumption that the... Several parameter identification methods of thermal response test were evaluated through numerical and experimental study.A three-dimensional finite-volume numerical model was established under the assumption that the soil thermal conductivity had been known in the simulation of thermal response test.The thermal response curve was firstly obtained through numerical calculation.Then,the accuracy of the numerical model was verified with measured data obtained through a thermal response test.Based on the numerical and experimental thermal response curves,the thermal conductivity of the soil was calculated by different parameter identification methods.The calculated results were compared with the assumed value and then the accuracy of these methods was evaluated.Furthermore,the effects of test time,variable data quality,borehole radius,initial ground temperature,and heat injection rate were analyzed.The results show that the method based on cylinder-source model has a low precision and the identified thermal conductivity decreases with an increase in borehole radius.For parameter estimation,the measuring accuracy of the initial temperature of the deep ground soil has greater effect on identified thermal conductivity. 展开更多
关键词 ground source heat pump thermal response parameter identification method numerical simulation
下载PDF
Comparative Analysis of Two Energy-Efficient Technologies Used in the Shanghai Tower
17
作者 Sarah Chen Yuyang Li 《Energy and Power Engineering》 2022年第1期1-12,共12页
Climate change continues to affect the lives of individuals across the world, creating a rise in demand for new technologies that can slow down the impacts of climate change. Shanghai, one of the largest cities in the... Climate change continues to affect the lives of individuals across the world, creating a rise in demand for new technologies that can slow down the impacts of climate change. Shanghai, one of the largest cities in the world, has one of the highest carbon emission levels. In recent years, the research and development of energy-efficient technologies have gained more and more attention. The Shanghai Tower is a pioneer in green building design and a prominent example of Shanghai’s efforts towards low-carbon city development. In this paper, two technologies within the Shanghai Tower<span style="font-family:Verdana;">—</span><span style="font-family:Verdana;">ground source heat pumps (GSHP) and double skin facades (DSF)</span><span style="font-family:Verdana;">—</span><span style="font-family:Verdana;">will be analyzed. The paper will consist of firstly an investigation of the principles of the technologies, and then analysis, evaluation, and comparison of their respective characteristics. While both GSHP and DSF are used for sustainable purposes, the effectiveness of technologies depends on what environment the technology is used in and what purpose they serve. The evaluation of GSHP and DSF will be based on their performances under Shanghai’s climate and whether they contribute to the purposes of the Shanghai Tower.</span> 展开更多
关键词 Shanghai Tower Green Buildings ground source heat pump Double Skin Facade Energy Efficiency
下载PDF
Numerical Simulation of Mid-Deep Buried Casing Heat Exchanger and its Heating System Application
18
作者 ZHOU Wenhe LI Rui +1 位作者 CHEN Yuying ZHU Shiqi 《Journal of Thermal Science》 SCIE EI CAS CSCD 2023年第4期1445-1454,共10页
Although the mid-deep ground source heat pump could be more excellent for heating compared to other heat pumps,whose well depth is usually 2000-4000 m underground,the references on it is far fewer than the market dema... Although the mid-deep ground source heat pump could be more excellent for heating compared to other heat pumps,whose well depth is usually 2000-4000 m underground,the references on it is far fewer than the market demand to apply it more.To facility the application of the mid-deep ground source heat pump and the heating problem solution to transform the coal-boiler used in a Logistics Park of Lanzhou city,firstly,this paper established a three-dimensional numerical model of mid-deep ground source heat exchanger,and analyzed the effects of well flow,diameter and depth on heat pump performance with the help of Fluent software.And then,the heating source renovation to mid-deep ground source heat pump was carried out and the test funded by the local government was followed from February 1,2018 to March 31,2018.It is concluded that the numerical analysis is reasonable and the heating system is effective and reliable,whose average COP(coefficient of performance)and cumulative power consumption is 3.47 and 67727 kWh respectively during the test period. 展开更多
关键词 heat pump ground source heat pump heat exchanger
原文传递
Numercial analysis on the thermal performance of capillary heat exchange system in metro running tunnel 被引量:1
19
作者 Mingyue Ren Yanping Yuan +2 位作者 Xiaoling Cao Liangliang Sun Fujian Jiang 《Energy and Built Environment》 2020年第2期207-214,共8页
During the operation of the capillary heat exchange system in the metro tunnel,the pipe length,pipe spacing and air velocity have different effects on the heat transfer effect and show certain rules.Taking Kunming as ... During the operation of the capillary heat exchange system in the metro tunnel,the pipe length,pipe spacing and air velocity have different effects on the heat transfer effect and show certain rules.Taking Kunming as an example,a single-factor analysis method was used to establish multiple-capillary model,and the variation of different influencing factors in the heat transfer process was obtained.On this basis,a single-capillary model was established to analyze the thermal interference variation of the pipe spacing between the two models.Under the condition of ensuring the capillary outlet water temperature and heat flux,the relevant parameters of the capillary heat exchanger were optimized.The results show that the pipe length of the capillary heat exchanger should be kept within 3-5 m,the pipe spacing is maintained at 20-30 mm,and the capillary heat exchanger of each set can be operated in parallel to ensure that heat exchanger have better heat transfer performance.During the system stop running,the air velocity in winter and summer has different effects on the recovery of surrounding rock. 展开更多
关键词 TUNNEL ground source heat pump heat exchanger Numerical simulation
原文传递
An Analysis of the Numerical Model Influence on the Ground TemperatureProfile Determination
20
作者 Marek Jaszczur Inga Polepszyc +1 位作者 Aneta Sapinska-Sliwa Andrzej Gonet 《Journal of Thermal Science》 SCIE EI CAS CSCD 2017年第1期82-88,共7页
The estimation of the ground temperature profile with respect to the depth and time is the key issue in many engineering applications which use the ground as a source of thermal energy. In the present work, the influe... The estimation of the ground temperature profile with respect to the depth and time is the key issue in many engineering applications which use the ground as a source of thermal energy. In the present work, the influence of the model components on the calculated ground temperature distribution has been analysed in order to develop an accurate and robust model for the prediction of the ground temperature profile. The presented mathematical model takes into account all the key phenomena occurring in the soil and on its top surface. The impact of individual model elements on the temperature of the soil has been analysed. It has been found that the simplest models and the most complex model result in a similar temperature variation over the simulation period, but only at a low depth. A detailed analysis shows that a larger depth requires more complex models and the calculation with the use of simple models results in an incorrect temperature and a theoretical COP estimation. 展开更多
关键词 heat transfer ground heat transport ground temperature profile ground source heat pump
原文传递