Elastic heat transfer tube bundles are widely used in the field of flow-induced vibration heat transfer enhancement. Two types of mainly used tube bundles, the planar elastic tube bundle and the conical spiral tube bu...Elastic heat transfer tube bundles are widely used in the field of flow-induced vibration heat transfer enhancement. Two types of mainly used tube bundles, the planar elastic tube bundle and the conical spiral tube bundle were comprehensively compared in the condition of the same shell side diameter. The natural mode characteristics, the effect of fluid-structure interaction, the stress distribution, the comprehensive heat transfer performance and the secondary fluid flow of the two elastic tube bundles were all concluded and compared. The results show that the natural frequency and the critical velocity of vibration buckling of the planar elastic tube bundle are larger than those of the conical spiral tube bundle, while the stress distribution and the comprehensive heat transfer performance of the conical spiral tube bundle are relatively better.展开更多
Experiments and simulations on flow and heat transfer behavior of Therminol-55 liquid phase heat transfer fluid have been conducted in a ribbed tube with the outer diameter and inner diameter 25.0 and 20.0 mm,pitch an...Experiments and simulations on flow and heat transfer behavior of Therminol-55 liquid phase heat transfer fluid have been conducted in a ribbed tube with the outer diameter and inner diameter 25.0 and 20.0 mm,pitch and rib height of 4.5 and 1.0 mm.respectively.Experimental results show that the heat transfer and thermal performance of Therminol-55 liquid phase heat transfer fluid in the ribbed tube are considerably improved compared to those of the smooth tube.The Nusselt number increase with the increase of Reynolds number.The increase in heat transfer rate of the ribbed tube has a mean value of 2.24 times.Also,the pressure drop results reveal that the average friction factor of the ribbed tube is in a range of 2.4 and 2.8 times over the smooth tube.Numerical simulations of three-dimensional flow behavior of Therminol-55 liquid phase heat transfer fluid are carried out using three different turbulence models in the ribbed tube.The numerical results show that the heat transfer of ribbed tube is improved because vortices are generated behind ribs,which produce some disruptions to fluid flow and enhance heat transfer compared with smooth tube.The numerical results prove that the ribbed tube can improve heat transfer and fluid flow performances of Therminol liquid phase heat transfer fluid.展开更多
The passive residual heat removal exchanger (PRHR HX),which is a key equipment of the passive residual heat removal system,is installed in an elevated pool.Its heat transfer performance affects security and economics ...The passive residual heat removal exchanger (PRHR HX),which is a key equipment of the passive residual heat removal system,is installed in an elevated pool.Its heat transfer performance affects security and economics of the reactor,and boiling heat transfer in the liquid surrounding the exchanger occurs when the liquid saturation temperature exceeded.The smooth tubes,which are widely used as heat transfer tubes in PRHR HX,can be replaced by some enhanced tubes to improve the boiling heat transfer capability.In this paper,the pool boiling heat transfer characteristics of smooth tube and a machined porous surface tube are investigated by using high-pressure steam condensing inside tube as heating source.Compared with smooth tube,the porous surface tube considerably enhances the boiling heat transfer,and shortens the time significantly before reaching the liquid saturation temperature.Its boiling heat transfer coefficient increases from 68% to 75%,and the wall superheat decreases by 1.5oC.Combining effect of condensation inside tube with boiling outside tube,the axial wall temperatures of heat transfer tube are neither uniform nor linear distribution.Based on these investigations,enhance mechanism of the porous surface tube is analyzed.展开更多
Experiments have been conducted on the pool boiling of binary mixtures in JK tubeswith porous surface and ribbed channels,attempting to enhace the boiling heat transfer coefficientsinvolved.The binary mixtures used in...Experiments have been conducted on the pool boiling of binary mixtures in JK tubeswith porous surface and ribbed channels,attempting to enhace the boiling heat transfer coefficientsinvolved.The binary mixtures used in this study are R113 and R11.The results show that the boilingfi1m heat transfer coefficients for the R113 and R11 binary mixtures in JK2 and JK1 tubes are 2—8tirnes and 2—5 times greater than those in smooth tubes respectively.Based on this experimentaldata and simple theoretical analysis,a correlation has been proposed to predict the boiling heattransfer coefficients for R113/R11 mixtures in a horizontal JK tube with a relative error of less than16%.展开更多
The enhancement of convective heat transfer in a glass tube heat exchanger was researched.A simple and efficient method using spiral wire turbulence promotors in the glass tube isrecommended.A series of experiments we...The enhancement of convective heat transfer in a glass tube heat exchanger was researched.A simple and efficient method using spiral wire turbulence promotors in the glass tube isrecommended.A series of experiments were conducted,and thetlon have been obtained.Performance evaluations Nr the enhanced heattrans比r In this heatexchanger are su门niii ed up and discussed Based on the vlewp01nt Of止berinodynaffi1CS,止he avaHableenergy lossof the heat transfer swtern Inside the tube Is analwed to determine and evaluate the over-all趴ct oQthe enhanced heat transfer,The mechanism ofenhanced heat transfer]n the glass tubeand the Influence of turbutlvlty In the fough tube are also analysed and discussed.展开更多
Numerical simulation on R245fa condensation inside an inner diameter of 8 mm horizontal tube is researched in this paper. The effect of variation in velocity, condensation temperature and superheat of inlet steam and ...Numerical simulation on R245fa condensation inside an inner diameter of 8 mm horizontal tube is researched in this paper. The effect of variation in velocity, condensation temperature and superheat of inlet steam and variation in cooling water temperature on heat transfer coefficient are investigated as a parametric study. Condensation process of steam has been successfully modeled by applying a user defined function (UDF) added to the commercial computational fluid dynamics (CFD) package. By analyzing the corresponding condensate contours and the curves of local heat transfer coefficient, the relationships between condensation heat transfer coefficient and various parameters of R245fa inside horizontal tube are obtained. It shows that the heat transfer coefficient increases by the increase in velocity, condensation temperature and superheat of inlet steam and the decrease in cooling water temperature. The errors between the heat transfer coefficient of simulation result and model of Wang and Shah are within ±30%. The parametric study will provide the basis for designing efficient heat exchangers of R245fa.展开更多
A polyethylene tube can be used as a heat exchanger for a low-running-cost?temperature control system. In this system, the flow of temperature-controlled?water in the tube is used as the heat source, and the tube is p...A polyethylene tube can be used as a heat exchanger for a low-running-cost?temperature control system. In this system, the flow of temperature-controlled?water in the tube is used as the heat source, and the tube is placed on the ceiling of a temperature-controlled space using a metal net. Owing to this structure, the tube is deformed by its weight. This deformation has a significant influence on heat transfer and flow characteristics. Therefore, an air injection method, in which air and water are injected simultaneously into the tube, is developed for preventing the deformation of the tube. In this study, bedding metal rods were used instead of a metal net. The influence of the pitch length of the metal rods (5 - 15 cm) and the width of the polyethylene tube 15, 20, 25, 30, and 35 cm was examined experimentally. The length of the polyethylene tube was 178 cm. The air flow rate was 9.5 × 10-5 m3/s. The water flow rates were 60, 80, 100, 120, and 140 mL/min. Results show that the thermal response improved because of air injection. In particular, the temperature at steady state increased, and steady state was attained approximately 1.2 - 3 times faster with air injection than without air injection. The optimum pitch length of the metal rods and the range of the optimum width of the polyethylene tube were 8 cm and 20 - 25 cm, respectively, with and without air injection.展开更多
Since convective boiling or highly subcooled single-phase forced convection in micro-channels is an effective cooling mechanism with a wide range of applications, more experimental and theoretical studies are re- quir...Since convective boiling or highly subcooled single-phase forced convection in micro-channels is an effective cooling mechanism with a wide range of applications, more experimental and theoretical studies are re- quired to explain and verify the forced convection heat transfer phenomenon in narrow channels. In this experimental study, we model the convective boiling behavior of water with low latent heat substance Freon 113 (R-113), with the purpose of saving power consumption and visualizing experiments. Both heat transfer and pressure drop characteris- tics were measured in subcooled and saturated concentric narrow gap forced convection boiling. Data were obtained to qualitatively identify the effects of gap size, pressure, flow rate and wall superheat on boiling regimes and the tran- sition between various regimes. Some significant differences from unconfined forced convection boiling were found, and also, the flow patterns in narrow vertical annulus tubes have been studied quantitatively.展开更多
In order to improve the thermal shock resistance of solar thermal heat transfer tube material, the mullite-cordierite composite ceramic as solar thermal heat transfer tube material were fabricated by pressureless sint...In order to improve the thermal shock resistance of solar thermal heat transfer tube material, the mullite-cordierite composite ceramic as solar thermal heat transfer tube material were fabricated by pressureless sintering using a-Al203, Suzhou kaolin, talc, and feldspar as starting materials. The important parameter for solar thermal transfer tube such as water absorption (W), bulk density (Db), and the mechanical properties were investigated. The phase composition and microstructure of the composite ceramics were analyzed by XRD and SEM. The experimental results show that the B3 sintered at 1 300 ℃ and holding for 3 h has an optimum thermal shock resistance. The bending strength loss rate of B3 is only 2% at 1 100℃ by air quenching-strength test and the sample can endure 30 times thermal shock cycling, and the water absorption, the bulk density and the bending strength are 0.32%, 2.58 g·cm-3, and 125.59 MPa respectively. The XRD analysis indicated that the phase compositions of the sample were mullite, cordierite, corundum, and spinel. The SEM images illustrate that the cordierite is prismatic grain and the mullite is nano rod, showing a good thermal shock resistance for composite ceramics as potential solar thermal power material.展开更多
Thermo-hydraulic characteristics of TiO_2-water nanofluids in thin-wall stainless steel test tubes(corrugated tube and circular tube) filled with copper foam(40 PPI) are experimentally investigated and compared with t...Thermo-hydraulic characteristics of TiO_2-water nanofluids in thin-wall stainless steel test tubes(corrugated tube and circular tube) filled with copper foam(40 PPI) are experimentally investigated and compared with those in test tubes without copper foam. The effects of nanoparticle mass concentration on flow and heat transfer performances are investigated. In addition, the mutual restriction relationships between Reynolds number(Re), Nusselt number(Nu) and resistance coefficient(f) are discussed respectively. Also, the comprehensive coefficient of performance(CCP) between heat transfer and pressure drop is evaluated. The results show that core-enhancement region for heat transfer using experimental tubes filled with copper foam is notably different from that of tubes without copper foam. There is a corresponding Reynolds number(about Re = 2400) for the maximum CCP of each condition. And the heat transfer can be enhanced dramatically and sustained at 8000 ≤ Re ≤ 12000.展开更多
Stable TiO_2–water nanofluids are prepared by a two-step method, stabilities of nanofluids are investigated by precipitation method and transmittance method respectively, and thermal conductivities and viscosities ar...Stable TiO_2–water nanofluids are prepared by a two-step method, stabilities of nanofluids are investigated by precipitation method and transmittance method respectively, and thermal conductivities and viscosities are also measured. An experimental system for studying the heat transfer enhancement of nanofluids is established,and heat transfer and flow characteristics of TiO_2–water nanofluids in heat exchanger systems with a triangular tube and circular tube are experimentally studied. The effects of nanoparticle mass fractions(ω = 0.1 wt%–0.5 wt%) and Reynolds numbers(Re = 800–10000) on the heat transfer and flow performances of nanofluids are analyzed. Fitting formulas for Nusselt number and resistance coefficient of nanofluids in a triangular tube are put forward based on the experimental data. The comprehensive performances of nanofluids in a triangular tube are investigated. It is found that nanofluids in a triangular tube can significantly improve the heat transfer performance at the cost of a small increase in resistance coefficient compared with that in a circular tube, especially the resistance coefficients are almost the same between different nanoparticle mass fractions at turbulent flow. It is also found that the comprehensive evaluation index η decreases with Reynolds number at laminar flow but a critical maximum value appears at turbulent flow.展开更多
The principle of thermal flux being constant in heat flow tube and the principle of heat balance were applied to analyze and calculate the steady state thermal field and the electrolyte ledge heat transfer coefficient...The principle of thermal flux being constant in heat flow tube and the principle of heat balance were applied to analyze and calculate the steady state thermal field and the electrolyte ledge heat transfer coefficient of aluminum reduction cell by finite element method. The calculated results show that the melt ledge heat transfer coefficient in the 160kA prebaked anode aluminum reduction cell of Guizhou Aluminum Smelter is higher than that of other cells of the same current. It is also found that the electrolyte and metal flow much faster, which may be the results of poor bus bar arrangements. Meanwhile, the calculated results of melt ledge heat transfer coefficient by heat flow tube method are almost in full agreement with the former works. This verifies the applicability of this method.展开更多
On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and an...On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and analyzed. The data obtained from test could match with the result deduced from theoretical calculation. From the test results,the cooling capacity of double U-tube is 1.6 times that of single U-tube. Taking cost per depth per watt Clq as the evaluation standard,Clq of single U-tube is 4.69 RMB$/W,and Clq of double U-tube is 3.14 RMB$/W. The double U-tube heat exchangers usage should be prioritized.展开更多
Natural gas is transported from producing regions to consumption regions by using transmission pipelines at high pressures. At consumption regions, the pressure of natural gas is reduced in city gate stations(CGSs). B...Natural gas is transported from producing regions to consumption regions by using transmission pipelines at high pressures. At consumption regions, the pressure of natural gas is reduced in city gate stations(CGSs). Before the pressure reduction process, the temperature of natural gas is increased usually by using a water bath heater,which burns natural gas as fuel, to protect against freezing of natural gas. These types of heat exchangers have a low efficiency and consume a lot of fuel to generate the required heat. In the current study, the twisted configuration of the heating coil is proposed and investigated to enhance the heat transfer through a water bath heater with a nominal capacity of 1000 m^3·h^-1. Firstly, the implementation procedure is validated with data collected from the CGS of Qaleh-Jiq(located in Golestan province of Iran). A very good agreement is achieved between the obtained results and the real data. Then, three different twist ratios are considered to examine the twisting effects. The proposed technique is evaluated in the terms of velocity, temperature, and pressure variations, and the results are compared with the conventional case, i.e. straight configuration. It is found that both the heat transfer rate and the pressure drop augment as the twist ratio is raised. Finally, it is concluded that the twisted tubes can reduce the length of the gas coil by about 12.5% for the model with low twist ratio, 18.75% for the model with medium twist ratio, and 25% for the model with high twist ratio as compared to the straight configuration.展开更多
In order to improve the performance of vehicle radiators, a two-dimensional heat transfer steady-state model of the radiator was set up. The influence of the structural parameters (axial ratio) of the heat exchange tu...In order to improve the performance of vehicle radiators, a two-dimensional heat transfer steady-state model of the radiator was set up. The influence of the structural parameters (axial ratio) of the heat exchange tube on the windward side on the heat transfer performance of the radiator was studied. With the increase of the axial ratio of the heat exchange tube on the windward side, the heat exchange capacity of the heat exchange tube surface slightly decreases. The heat exchange area increases significantly, which increases the total heat exchange of the radiator and improves the heat transfer performance of the radiator. When the axial ratio increases from 1.0 to 2.0, the average surface heat transfer capacity decreases from 5664.16</span><span style="font-family:""> </span><span style="font-family:Verdana;">W/m<sup>2</sup> to 5623.57</span><span style="font-family:""> </span><span style="font-family:Verdana;">W/m<sup>2</sup>.展开更多
The mechanism of pre roll ploughing for 3D fins on the outside surface of copper tube was studied systematically, and especially the process and conditions of 3D fin formation were analyzed. The right mathematical mod...The mechanism of pre roll ploughing for 3D fins on the outside surface of copper tube was studied systematically, and especially the process and conditions of 3D fin formation were analyzed. The right mathematical model was also established. Based on the volume of fin ploughed out is equal to the volume of the metal extruded up by the extruding face of the tool, the relations between fin height, pre roll ploughing feed and pre roll ploughing depth have been achieved. With the increase of pre roll ploughing depth which must be equal to groove depth, the fin height gradually becomes larger. There are different critical feeds with the various depths of pre roll ploughing. The pre roll ploughing feed is the critical one, the height of fin is largest. And when the feed is above the critical one, the fin height will reduce with the increase of feed. The theoretical analysis basically accords with experimental results.展开更多
To predicate the temperature distribution of concrete-filled steel tubes(CFSTs) being exposure to fire,a finite element analysis model was developed using a finite element package,ANSYS.A suggested value of contact th...To predicate the temperature distribution of concrete-filled steel tubes(CFSTs) being exposure to fire,a finite element analysis model was developed using a finite element package,ANSYS.A suggested value of contact thermal resistance was therefore proposed with the supporting of massive numbers of collected test data.Parametric analysis was conducted subsequently towards the cross-sectional temperature distribution of CFST columns in four-side fire,in which the exposure time,width of the cross section,steel ratio were taken into account with considering contact thermal resistance.It was found that contact thermal resistance has little effect on the overall temperature regulation with the exposure time,the width of cross-section or the change of steel ratio.However,great temperature dropping at the concrete adjacent to the contact interface,and gentle temperature increase at steel tube,exist if considering contact thermal resistance.The results of the study are expected to provide theoretical basis for the fire resistance behavior and design of the CFST columns being exposure to fire.展开更多
Using rolling-ploughing-extrusion compound processing methods,a 3D integral-fin structure on outside surface of red copper tube with diameter of 16.0 mm and wall thickness of 1.5 mm was obtained. When both rolling dep...Using rolling-ploughing-extrusion compound processing methods,a 3D integral-fin structure on outside surface of red copper tube with diameter of 16.0 mm and wall thickness of 1.5 mm was obtained. When both rolling depth and ploughing-extrusion(P-E) depth were 0.2 mm,rotating speed was 50 r/min,feed speed was 0.16 mm/r,3D fin structures with height of 0.25 mm were gotten. Two different fin structures were obtained in grooves formed with rolling-ploughing-extrusion compound forming technology and observed by scanning electron microscope(SEM). One is the compound structure with V-shaped groove and U-shaped groove,and the other is the single structure with V-shaped grooves. Two kinds of groove structures obtained by rolling processing and ploughing extrusion processing are restricted together by groove interval and rolling depth,and pitch and P-E depth,respectively. Based on the analysis of interaction of rolling and P-E processing,it is found from the result that the outside 3D integral-fin can be achieved by rolling-ploughing-extrusion compound processing when single V-shaped groove structures are formed by both rolling and P-E processing.展开更多
The global energy demand increases with development and population rise. Most electrical power is currently generated by conventional methods from fossil fuels. Despite the high energy demand, the conventional energy ...The global energy demand increases with development and population rise. Most electrical power is currently generated by conventional methods from fossil fuels. Despite the high energy demand, the conventional energy resources such as fossil fuels have been declining and harmful combustion byproducts are causing global warming. The Organic Rankine Cycle power plant is a very effective option for utilization of low grade heat sources for power generation. In the Organic Rankine Cycle heat exchangers such as evaporators and condensers are key components that determine its performance. Researches indicated that shell tube heat exchangers are effectively utilized in this cycle. The design of the heat exchanger involves establishing the right flow pattern of the interacting fluids. The performance of these exchangers can be optimized by inserting baffles in the shell to direct the flow of fluid across the tubes on shell side. In this work heat exchangers have been developed to improve heat recovery from geothermal brine for additional power generation. The design involved sizing of heat exchanger (evaporator) using the LMTD method based on an expected heat transfer rate. The heat exchanger of the model power plant was tested in which hot water simulated brine. The results indicated that the heat exchanger is thermally suitable for the evaporator of the model power plant.展开更多
A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distr...A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distribution.Water and polyformaldehyde particle(POM)were used as the liquid and solid phases,respectively.The effects of operating parameters such as the amount of added particles,circulating flow rate,and particle size were systematically investigated.The results showed that the addition of the particles increased the pressure drop in the vertical tube bundle.The maximum pressure drop ratios were 18.65%,21.15%,18.00%,and 21.15%within the experimental range of the amount of added particles for POM1,POM2,POM3,and POM4,respectively.The pressure drop ratio basically decreased with the increase in the circulating flow rate but fluctuated with the increase in the amount of added particles and particle size.The difference in pressure drop ratio decreased with the increase in the circulating flow rate.As the amount of added particles increased,the difference in pressure drop ratio fluctuated at low circulating flow rate but basically decreased at high circulating flow rate.The pressure drop in the vertical tube bundle accounted for about 70%of the overall pressure drop in the up-flow heating chamber and was the main component of the overall pressure within the experimental range.Three-dimensional phase diagrams were established to display the variation ranges of the pressure drop and pressure drop ratio in the vertical tube bundle corresponding to the operating parameters.The research results can provide some reference for the application of the fluidized bed heat transfer technology in the industry.展开更多
基金Projects(xjj2013104,08143063)supported by the Fundamental Research Funds for the Central Universities,ChinaProject(2011CB706606)supported by the National Basic Research Program of China
文摘Elastic heat transfer tube bundles are widely used in the field of flow-induced vibration heat transfer enhancement. Two types of mainly used tube bundles, the planar elastic tube bundle and the conical spiral tube bundle were comprehensively compared in the condition of the same shell side diameter. The natural mode characteristics, the effect of fluid-structure interaction, the stress distribution, the comprehensive heat transfer performance and the secondary fluid flow of the two elastic tube bundles were all concluded and compared. The results show that the natural frequency and the critical velocity of vibration buckling of the planar elastic tube bundle are larger than those of the conical spiral tube bundle, while the stress distribution and the comprehensive heat transfer performance of the conical spiral tube bundle are relatively better.
基金Supported by the National Natural Science Foundation of China(11472093 and21276056)
文摘Experiments and simulations on flow and heat transfer behavior of Therminol-55 liquid phase heat transfer fluid have been conducted in a ribbed tube with the outer diameter and inner diameter 25.0 and 20.0 mm,pitch and rib height of 4.5 and 1.0 mm.respectively.Experimental results show that the heat transfer and thermal performance of Therminol-55 liquid phase heat transfer fluid in the ribbed tube are considerably improved compared to those of the smooth tube.The Nusselt number increase with the increase of Reynolds number.The increase in heat transfer rate of the ribbed tube has a mean value of 2.24 times.Also,the pressure drop results reveal that the average friction factor of the ribbed tube is in a range of 2.4 and 2.8 times over the smooth tube.Numerical simulations of three-dimensional flow behavior of Therminol-55 liquid phase heat transfer fluid are carried out using three different turbulence models in the ribbed tube.The numerical results show that the heat transfer of ribbed tube is improved because vortices are generated behind ribs,which produce some disruptions to fluid flow and enhance heat transfer compared with smooth tube.The numerical results prove that the ribbed tube can improve heat transfer and fluid flow performances of Therminol liquid phase heat transfer fluid.
文摘The passive residual heat removal exchanger (PRHR HX),which is a key equipment of the passive residual heat removal system,is installed in an elevated pool.Its heat transfer performance affects security and economics of the reactor,and boiling heat transfer in the liquid surrounding the exchanger occurs when the liquid saturation temperature exceeded.The smooth tubes,which are widely used as heat transfer tubes in PRHR HX,can be replaced by some enhanced tubes to improve the boiling heat transfer capability.In this paper,the pool boiling heat transfer characteristics of smooth tube and a machined porous surface tube are investigated by using high-pressure steam condensing inside tube as heating source.Compared with smooth tube,the porous surface tube considerably enhances the boiling heat transfer,and shortens the time significantly before reaching the liquid saturation temperature.Its boiling heat transfer coefficient increases from 68% to 75%,and the wall superheat decreases by 1.5oC.Combining effect of condensation inside tube with boiling outside tube,the axial wall temperatures of heat transfer tube are neither uniform nor linear distribution.Based on these investigations,enhance mechanism of the porous surface tube is analyzed.
基金Supported by the National Natural Science Foundation of China and Guangdong Province Science Foundation of China.
文摘Experiments have been conducted on the pool boiling of binary mixtures in JK tubeswith porous surface and ribbed channels,attempting to enhace the boiling heat transfer coefficientsinvolved.The binary mixtures used in this study are R113 and R11.The results show that the boilingfi1m heat transfer coefficients for the R113 and R11 binary mixtures in JK2 and JK1 tubes are 2—8tirnes and 2—5 times greater than those in smooth tubes respectively.Based on this experimentaldata and simple theoretical analysis,a correlation has been proposed to predict the boiling heattransfer coefficients for R113/R11 mixtures in a horizontal JK tube with a relative error of less than16%.
文摘The enhancement of convective heat transfer in a glass tube heat exchanger was researched.A simple and efficient method using spiral wire turbulence promotors in the glass tube isrecommended.A series of experiments were conducted,and thetlon have been obtained.Performance evaluations Nr the enhanced heattrans比r In this heatexchanger are su门niii ed up and discussed Based on the vlewp01nt Of止berinodynaffi1CS,止he avaHableenergy lossof the heat transfer swtern Inside the tube Is analwed to determine and evaluate the over-all趴ct oQthe enhanced heat transfer,The mechanism ofenhanced heat transfer]n the glass tubeand the Influence of turbutlvlty In the fough tube are also analysed and discussed.
文摘Numerical simulation on R245fa condensation inside an inner diameter of 8 mm horizontal tube is researched in this paper. The effect of variation in velocity, condensation temperature and superheat of inlet steam and variation in cooling water temperature on heat transfer coefficient are investigated as a parametric study. Condensation process of steam has been successfully modeled by applying a user defined function (UDF) added to the commercial computational fluid dynamics (CFD) package. By analyzing the corresponding condensate contours and the curves of local heat transfer coefficient, the relationships between condensation heat transfer coefficient and various parameters of R245fa inside horizontal tube are obtained. It shows that the heat transfer coefficient increases by the increase in velocity, condensation temperature and superheat of inlet steam and the decrease in cooling water temperature. The errors between the heat transfer coefficient of simulation result and model of Wang and Shah are within ±30%. The parametric study will provide the basis for designing efficient heat exchangers of R245fa.
文摘A polyethylene tube can be used as a heat exchanger for a low-running-cost?temperature control system. In this system, the flow of temperature-controlled?water in the tube is used as the heat source, and the tube is placed on the ceiling of a temperature-controlled space using a metal net. Owing to this structure, the tube is deformed by its weight. This deformation has a significant influence on heat transfer and flow characteristics. Therefore, an air injection method, in which air and water are injected simultaneously into the tube, is developed for preventing the deformation of the tube. In this study, bedding metal rods were used instead of a metal net. The influence of the pitch length of the metal rods (5 - 15 cm) and the width of the polyethylene tube 15, 20, 25, 30, and 35 cm was examined experimentally. The length of the polyethylene tube was 178 cm. The air flow rate was 9.5 × 10-5 m3/s. The water flow rates were 60, 80, 100, 120, and 140 mL/min. Results show that the thermal response improved because of air injection. In particular, the temperature at steady state increased, and steady state was attained approximately 1.2 - 3 times faster with air injection than without air injection. The optimum pitch length of the metal rods and the range of the optimum width of the polyethylene tube were 8 cm and 20 - 25 cm, respectively, with and without air injection.
基金Supported by the 973 Project of China (G1999022308) and the Knowledge Innovation Program of the Chinese Academy of Sciences (KJCX2-SW-L05)
文摘Since convective boiling or highly subcooled single-phase forced convection in micro-channels is an effective cooling mechanism with a wide range of applications, more experimental and theoretical studies are re- quired to explain and verify the forced convection heat transfer phenomenon in narrow channels. In this experimental study, we model the convective boiling behavior of water with low latent heat substance Freon 113 (R-113), with the purpose of saving power consumption and visualizing experiments. Both heat transfer and pressure drop characteris- tics were measured in subcooled and saturated concentric narrow gap forced convection boiling. Data were obtained to qualitatively identify the effects of gap size, pressure, flow rate and wall superheat on boiling regimes and the tran- sition between various regimes. Some significant differences from unconfined forced convection boiling were found, and also, the flow patterns in narrow vertical annulus tubes have been studied quantitatively.
基金Funded by the Major State Basic Research Development Program of China(973 Program)(No.2010CB227105)
文摘In order to improve the thermal shock resistance of solar thermal heat transfer tube material, the mullite-cordierite composite ceramic as solar thermal heat transfer tube material were fabricated by pressureless sintering using a-Al203, Suzhou kaolin, talc, and feldspar as starting materials. The important parameter for solar thermal transfer tube such as water absorption (W), bulk density (Db), and the mechanical properties were investigated. The phase composition and microstructure of the composite ceramics were analyzed by XRD and SEM. The experimental results show that the B3 sintered at 1 300 ℃ and holding for 3 h has an optimum thermal shock resistance. The bending strength loss rate of B3 is only 2% at 1 100℃ by air quenching-strength test and the sample can endure 30 times thermal shock cycling, and the water absorption, the bulk density and the bending strength are 0.32%, 2.58 g·cm-3, and 125.59 MPa respectively. The XRD analysis indicated that the phase compositions of the sample were mullite, cordierite, corundum, and spinel. The SEM images illustrate that the cordierite is prismatic grain and the mullite is nano rod, showing a good thermal shock resistance for composite ceramics as potential solar thermal power material.
基金Supported by the National Natural Science Foundation of China(51606214)
文摘Thermo-hydraulic characteristics of TiO_2-water nanofluids in thin-wall stainless steel test tubes(corrugated tube and circular tube) filled with copper foam(40 PPI) are experimentally investigated and compared with those in test tubes without copper foam. The effects of nanoparticle mass concentration on flow and heat transfer performances are investigated. In addition, the mutual restriction relationships between Reynolds number(Re), Nusselt number(Nu) and resistance coefficient(f) are discussed respectively. Also, the comprehensive coefficient of performance(CCP) between heat transfer and pressure drop is evaluated. The results show that core-enhancement region for heat transfer using experimental tubes filled with copper foam is notably different from that of tubes without copper foam. There is a corresponding Reynolds number(about Re = 2400) for the maximum CCP of each condition. And the heat transfer can be enhanced dramatically and sustained at 8000 ≤ Re ≤ 12000.
基金Supported by the National Natural Science Foundation of China(51606214)
文摘Stable TiO_2–water nanofluids are prepared by a two-step method, stabilities of nanofluids are investigated by precipitation method and transmittance method respectively, and thermal conductivities and viscosities are also measured. An experimental system for studying the heat transfer enhancement of nanofluids is established,and heat transfer and flow characteristics of TiO_2–water nanofluids in heat exchanger systems with a triangular tube and circular tube are experimentally studied. The effects of nanoparticle mass fractions(ω = 0.1 wt%–0.5 wt%) and Reynolds numbers(Re = 800–10000) on the heat transfer and flow performances of nanofluids are analyzed. Fitting formulas for Nusselt number and resistance coefficient of nanofluids in a triangular tube are put forward based on the experimental data. The comprehensive performances of nanofluids in a triangular tube are investigated. It is found that nanofluids in a triangular tube can significantly improve the heat transfer performance at the cost of a small increase in resistance coefficient compared with that in a circular tube, especially the resistance coefficients are almost the same between different nanoparticle mass fractions at turbulent flow. It is also found that the comprehensive evaluation index η decreases with Reynolds number at laminar flow but a critical maximum value appears at turbulent flow.
文摘The principle of thermal flux being constant in heat flow tube and the principle of heat balance were applied to analyze and calculate the steady state thermal field and the electrolyte ledge heat transfer coefficient of aluminum reduction cell by finite element method. The calculated results show that the melt ledge heat transfer coefficient in the 160kA prebaked anode aluminum reduction cell of Guizhou Aluminum Smelter is higher than that of other cells of the same current. It is also found that the electrolyte and metal flow much faster, which may be the results of poor bus bar arrangements. Meanwhile, the calculated results of melt ledge heat transfer coefficient by heat flow tube method are almost in full agreement with the former works. This verifies the applicability of this method.
文摘On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and analyzed. The data obtained from test could match with the result deduced from theoretical calculation. From the test results,the cooling capacity of double U-tube is 1.6 times that of single U-tube. Taking cost per depth per watt Clq as the evaluation standard,Clq of single U-tube is 4.69 RMB$/W,and Clq of double U-tube is 3.14 RMB$/W. The double U-tube heat exchangers usage should be prioritized.
基金Islamic Azad University(IAU)Shahrood Branch,Shahrood,IranGolestan Province Gas Company,Gorgan,Iran for their sponsorships.
文摘Natural gas is transported from producing regions to consumption regions by using transmission pipelines at high pressures. At consumption regions, the pressure of natural gas is reduced in city gate stations(CGSs). Before the pressure reduction process, the temperature of natural gas is increased usually by using a water bath heater,which burns natural gas as fuel, to protect against freezing of natural gas. These types of heat exchangers have a low efficiency and consume a lot of fuel to generate the required heat. In the current study, the twisted configuration of the heating coil is proposed and investigated to enhance the heat transfer through a water bath heater with a nominal capacity of 1000 m^3·h^-1. Firstly, the implementation procedure is validated with data collected from the CGS of Qaleh-Jiq(located in Golestan province of Iran). A very good agreement is achieved between the obtained results and the real data. Then, three different twist ratios are considered to examine the twisting effects. The proposed technique is evaluated in the terms of velocity, temperature, and pressure variations, and the results are compared with the conventional case, i.e. straight configuration. It is found that both the heat transfer rate and the pressure drop augment as the twist ratio is raised. Finally, it is concluded that the twisted tubes can reduce the length of the gas coil by about 12.5% for the model with low twist ratio, 18.75% for the model with medium twist ratio, and 25% for the model with high twist ratio as compared to the straight configuration.
文摘In order to improve the performance of vehicle radiators, a two-dimensional heat transfer steady-state model of the radiator was set up. The influence of the structural parameters (axial ratio) of the heat exchange tube on the windward side on the heat transfer performance of the radiator was studied. With the increase of the axial ratio of the heat exchange tube on the windward side, the heat exchange capacity of the heat exchange tube surface slightly decreases. The heat exchange area increases significantly, which increases the total heat exchange of the radiator and improves the heat transfer performance of the radiator. When the axial ratio increases from 1.0 to 2.0, the average surface heat transfer capacity decreases from 5664.16</span><span style="font-family:""> </span><span style="font-family:Verdana;">W/m<sup>2</sup> to 5623.57</span><span style="font-family:""> </span><span style="font-family:Verdana;">W/m<sup>2</sup>.
文摘The mechanism of pre roll ploughing for 3D fins on the outside surface of copper tube was studied systematically, and especially the process and conditions of 3D fin formation were analyzed. The right mathematical model was also established. Based on the volume of fin ploughed out is equal to the volume of the metal extruded up by the extruding face of the tool, the relations between fin height, pre roll ploughing feed and pre roll ploughing depth have been achieved. With the increase of pre roll ploughing depth which must be equal to groove depth, the fin height gradually becomes larger. There are different critical feeds with the various depths of pre roll ploughing. The pre roll ploughing feed is the critical one, the height of fin is largest. And when the feed is above the critical one, the fin height will reduce with the increase of feed. The theoretical analysis basically accords with experimental results.
基金Sponsored by the National Natural Science Foundation of China(Grant No.50708028)the Postdoctoral Foundation of Heilongjiang Province(GrantNo.LBH-Q07048)
文摘To predicate the temperature distribution of concrete-filled steel tubes(CFSTs) being exposure to fire,a finite element analysis model was developed using a finite element package,ANSYS.A suggested value of contact thermal resistance was therefore proposed with the supporting of massive numbers of collected test data.Parametric analysis was conducted subsequently towards the cross-sectional temperature distribution of CFST columns in four-side fire,in which the exposure time,width of the cross section,steel ratio were taken into account with considering contact thermal resistance.It was found that contact thermal resistance has little effect on the overall temperature regulation with the exposure time,the width of cross-section or the change of steel ratio.However,great temperature dropping at the concrete adjacent to the contact interface,and gentle temperature increase at steel tube,exist if considering contact thermal resistance.The results of the study are expected to provide theoretical basis for the fire resistance behavior and design of the CFST columns being exposure to fire.
基金Projects(50436010, 50675070) supported by the National Natural Science Foundation of ChinaProject(07118064) supported by the Natural Science Foundation of Guangdong Province, China
文摘Using rolling-ploughing-extrusion compound processing methods,a 3D integral-fin structure on outside surface of red copper tube with diameter of 16.0 mm and wall thickness of 1.5 mm was obtained. When both rolling depth and ploughing-extrusion(P-E) depth were 0.2 mm,rotating speed was 50 r/min,feed speed was 0.16 mm/r,3D fin structures with height of 0.25 mm were gotten. Two different fin structures were obtained in grooves formed with rolling-ploughing-extrusion compound forming technology and observed by scanning electron microscope(SEM). One is the compound structure with V-shaped groove and U-shaped groove,and the other is the single structure with V-shaped grooves. Two kinds of groove structures obtained by rolling processing and ploughing extrusion processing are restricted together by groove interval and rolling depth,and pitch and P-E depth,respectively. Based on the analysis of interaction of rolling and P-E processing,it is found from the result that the outside 3D integral-fin can be achieved by rolling-ploughing-extrusion compound processing when single V-shaped groove structures are formed by both rolling and P-E processing.
文摘The global energy demand increases with development and population rise. Most electrical power is currently generated by conventional methods from fossil fuels. Despite the high energy demand, the conventional energy resources such as fossil fuels have been declining and harmful combustion byproducts are causing global warming. The Organic Rankine Cycle power plant is a very effective option for utilization of low grade heat sources for power generation. In the Organic Rankine Cycle heat exchangers such as evaporators and condensers are key components that determine its performance. Researches indicated that shell tube heat exchangers are effectively utilized in this cycle. The design of the heat exchanger involves establishing the right flow pattern of the interacting fluids. The performance of these exchangers can be optimized by inserting baffles in the shell to direct the flow of fluid across the tubes on shell side. In this work heat exchangers have been developed to improve heat recovery from geothermal brine for additional power generation. The design involved sizing of heat exchanger (evaporator) using the LMTD method based on an expected heat transfer rate. The heat exchanger of the model power plant was tested in which hot water simulated brine. The results indicated that the heat exchanger is thermally suitable for the evaporator of the model power plant.
基金supported by the open foundation of State Key Laboratory of Chemical Engineering (SKL-ChE-18B03)the Municipal Science and Technology Commission of Tianjin (No. 2009ZCKFGX01900)
文摘A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distribution.Water and polyformaldehyde particle(POM)were used as the liquid and solid phases,respectively.The effects of operating parameters such as the amount of added particles,circulating flow rate,and particle size were systematically investigated.The results showed that the addition of the particles increased the pressure drop in the vertical tube bundle.The maximum pressure drop ratios were 18.65%,21.15%,18.00%,and 21.15%within the experimental range of the amount of added particles for POM1,POM2,POM3,and POM4,respectively.The pressure drop ratio basically decreased with the increase in the circulating flow rate but fluctuated with the increase in the amount of added particles and particle size.The difference in pressure drop ratio decreased with the increase in the circulating flow rate.As the amount of added particles increased,the difference in pressure drop ratio fluctuated at low circulating flow rate but basically decreased at high circulating flow rate.The pressure drop in the vertical tube bundle accounted for about 70%of the overall pressure drop in the up-flow heating chamber and was the main component of the overall pressure within the experimental range.Three-dimensional phase diagrams were established to display the variation ranges of the pressure drop and pressure drop ratio in the vertical tube bundle corresponding to the operating parameters.The research results can provide some reference for the application of the fluidized bed heat transfer technology in the industry.