In accelerator RF cavities, there exists not only the fundamental mode which is used to accelerate the beam, but also higher order modes(HOMs). The higher order modes excited by the beam can seriously affect beam qu...In accelerator RF cavities, there exists not only the fundamental mode which is used to accelerate the beam, but also higher order modes(HOMs). The higher order modes excited by the beam can seriously affect beam quality, especially for the higher R/Q modes. 1.3 GHz low-loss 9-cell superconducting cavity as a candidate for ILC high gradient cavity, the properties of higher order mode has not been studied carefully. IHEP based on existing low loss cavity, designed and developed a large grain size 1.3 GHz low-loss 9-cell superconducting cavity(IHEP02cavity). The higher order mode coupler of IHEP02 used TESLA coupler's design. As a result of the limitation of the mechanical design, the distance between higher order mode coupler and end cell is larger than TESLA cavity.This paper reports on measured results of higher order modes in the IHEP02 1.3 GHz low-loss 9-cell superconducting cavity. Using different methods, Q e of the dangerous modes passbands have been obtained. The results are compared with TESLA cavity results. R/Q of the first three passbands have also been obtained by simulation and compared with the results of the TESLA cavity.展开更多
基金Supported by Knowledge Innovation Project of The Chinese Academy of Sciences
文摘In accelerator RF cavities, there exists not only the fundamental mode which is used to accelerate the beam, but also higher order modes(HOMs). The higher order modes excited by the beam can seriously affect beam quality, especially for the higher R/Q modes. 1.3 GHz low-loss 9-cell superconducting cavity as a candidate for ILC high gradient cavity, the properties of higher order mode has not been studied carefully. IHEP based on existing low loss cavity, designed and developed a large grain size 1.3 GHz low-loss 9-cell superconducting cavity(IHEP02cavity). The higher order mode coupler of IHEP02 used TESLA coupler's design. As a result of the limitation of the mechanical design, the distance between higher order mode coupler and end cell is larger than TESLA cavity.This paper reports on measured results of higher order modes in the IHEP02 1.3 GHz low-loss 9-cell superconducting cavity. Using different methods, Q e of the dangerous modes passbands have been obtained. The results are compared with TESLA cavity results. R/Q of the first three passbands have also been obtained by simulation and compared with the results of the TESLA cavity.