An experimental investigation was conducted to measure the temperature variation across the flow channel and to determine the performance of a natural convection solar air heater at various tilt angles from 15, 30 and...An experimental investigation was conducted to measure the temperature variation across the flow channel and to determine the performance of a natural convection solar air heater at various tilt angles from 15, 30 and 45°. The results of the temperature profile across the air gap showed that heat transfer from the absorber plate to the air stream was mainly by convection. At a particular section, mean air temperature could be calculated from the arithmetic mean of the temperature profile across the air gap to within ± 2 ℃. The axial air temperature distribution was non linear and did not increase much beyond 1 m of collector length. It tended to decrease towards the end of the collector. Overall glass, absorber plate and mean air temperatures over the entire length of the solar air heater could be determined by averaging the mean axial temperatures to within ± 2 ℃. The heater performed better as inclination increased.展开更多
Peristaltic transport of a Newtonian incompressible fluid in the presence of applied mag netic field in an inclined channel with slip is investigated. A perturbation method of solu tion is obtained in terms of wall sl...Peristaltic transport of a Newtonian incompressible fluid in the presence of applied mag netic field in an inclined channel with slip is investigated. A perturbation method of solu tion is obtained in terms of wall slope parameter and analytical expressions are derived for average velocity and stream function using Saffman slip condition. The effects of var ious relevant parameters on average velocity and stream line pattern have been studied. It is found that average velocity increases with slip and decreases with permeability and magnetic parameter.展开更多
文摘An experimental investigation was conducted to measure the temperature variation across the flow channel and to determine the performance of a natural convection solar air heater at various tilt angles from 15, 30 and 45°. The results of the temperature profile across the air gap showed that heat transfer from the absorber plate to the air stream was mainly by convection. At a particular section, mean air temperature could be calculated from the arithmetic mean of the temperature profile across the air gap to within ± 2 ℃. The axial air temperature distribution was non linear and did not increase much beyond 1 m of collector length. It tended to decrease towards the end of the collector. Overall glass, absorber plate and mean air temperatures over the entire length of the solar air heater could be determined by averaging the mean axial temperatures to within ± 2 ℃. The heater performed better as inclination increased.
文摘Peristaltic transport of a Newtonian incompressible fluid in the presence of applied mag netic field in an inclined channel with slip is investigated. A perturbation method of solu tion is obtained in terms of wall slope parameter and analytical expressions are derived for average velocity and stream function using Saffman slip condition. The effects of var ious relevant parameters on average velocity and stream line pattern have been studied. It is found that average velocity increases with slip and decreases with permeability and magnetic parameter.