Determination on Heavy Metals Content of Achyranthes bidentata Blume. through Inductively Coupled Plasma Mass Spectrometry (ICP-MS) 被引量:4
1
作者 李宇伟 王新民 +3 位作者 连瑞丽 魏志华 介晓磊 陈士林 《Agricultural Science & Technology》 CAS 2008年第5期145-149,共5页
[Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation con... [Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation condition of ICP-MS,the samples were digested by microwave.The element 114In was taken as an internal standard element to compensate body effect and ICP-MS method was used to determine the contents of lead,cadmium,mercury and arsenic.[Result]For the determined elements,the correlation coefficient(r)of standard curve was over 0.9995 and recovery rate was from 96.7% to 106.4% while RSD was less than 11.2%.The result of determination showed that the heavy metal content in Archyranthes bidentata Blume.beyond standard was serious.[Conclusion]The constructed ICP-MS method with simple operation,rapid response,accuracy and high sensitivity in this experiment could be used for quality control of Chinese medicinal materials by detecting heavy metal contents in different Chinese medicinal materials from original places. 展开更多
关键词 MICROWAVE DIGESTION inductively coupled plasma mass spectrometry(icp-MS) Achyranthes bidentata Blume. HEAVY metal
下载PDF
Diagnostics of Argon Inductively Coupled Plasma and Dielectric Barrier Discharge Plasma by Optical Emission Spectroscopy
2
作者 张家良 俞世吉 +1 位作者 马滕才 邓新绿 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第4期883-890,共8页
An experimental setup was built up to carry out radio frequency (RF) inductively coupled plasma (ICP) and dielectric barrier discharge (DBD), and to depict the optical emission spectra (OES) of the discharges. OES fro... An experimental setup was built up to carry out radio frequency (RF) inductively coupled plasma (ICP) and dielectric barrier discharge (DBD), and to depict the optical emission spectra (OES) of the discharges. OES from argon ICP and DBD plasmas in visible and near ultraviolet region were measured. For argon ICP, the higher RF power input (higher than 500 W for our machine), the higher degree of argon plasma ionization. But that doesn't mean a higher mean electron energy. With the increase in the power input, the mean electron energy increases slightly, whereas the density of electron increases apparently On the contrary, argon DBD discharge behaves in the manner of a pulsed DC discharge on optical emission spectroscopy and V-I characteristics. DBD current is composed of a series of pulses equally spaced in temporal domain. The Kinetics of DBD emission strength is mainly governed by the frequency of the current pulse. 展开更多
关键词 In icp Diagnostics of Argon inductively coupled plasma and Dielectric Barrier discharge plasma by Optical Emission Spectroscopy
下载PDF
Effects of direct current discharge on the spatial distribution of cylindrical inductively-coupled plasma at different gas pressures
3
作者 滑跃 宋健 +2 位作者 郝泽宇 张改玲 任春生 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第1期32-40,共9页
Stable operations of single direct current (DC) discharge, single radio frequency (RF) discharge and DC + RF hybrid discharge are achieved in a specially-designed DC enhanced inductively- coupled plasma (DCE-ICP... Stable operations of single direct current (DC) discharge, single radio frequency (RF) discharge and DC + RF hybrid discharge are achieved in a specially-designed DC enhanced inductively- coupled plasma (DCE-ICP) source. Their plasma characteristics, such as electron density, electron temperature and the electron density spatial distribution profiles are investigated and compared experimentally at different gas pressures. It is found that under the condition of single RF discharge, the electron density distribution profiles show a 'convex' shape and 'saddle' shape at gas pressures of 3 mTorr and 150 mTorr respectively. This result can be attributed to the transition of electron kinetics from nonlocal to local kinetics with an increase in gas pressure. Moreover, in the operation of DC q- RF hybrid discharge at different gas pressures, the DC discharge has different effects on plasma uniformity. The plasma uniformity can be improved by modulating DC power at a high pressure of 150 mTorr where local electron kinetics is dominant, whereas plasma uniformity deteriorates at a low pressure of 3 mTorr where nonlocal electron kinetics prevails. This phenomenon, as analyzed, is due to the obvious nonlinear enhancement effect of electron density at the chamber center, and the inherent radial distribution difference in the electron density with single RF discharge at different gas pressures. 展开更多
关键词 cylindrical inductively-coupled plasma DC RF hybrid discharge plasmauniformity gas pressure
下载PDF
Microstructure, Hardness and Corrosion Resistance of ZrN Films Prepared by Inductively Coupled Plasma Enhanced RF Magnetron Sputtering 被引量:4
4
作者 文峰 孟月东 +1 位作者 任兆杏 舒兴胜 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第2期170-175,共6页
ZrN fihns were deposited on Si(111) and M2 steel by inductively coupled plasma (ICP)-enhanced RF magnetron sputtering. The effect of ICP power on the microstructure, mechanical properties and corrosion resistance ... ZrN fihns were deposited on Si(111) and M2 steel by inductively coupled plasma (ICP)-enhanced RF magnetron sputtering. The effect of ICP power on the microstructure, mechanical properties and corrosion resistance of ZrN films was investigated. When the ICP power is below 300 W, the ZrN films show a columnar structure. With the increase of ICP power, the texture coefficient (To) of the (111) plane, the nanohardness and elastic modulus of the films increase and reach the maximum at a power of 300 W. As the ICP Power exceeds 300 W, the films exhibit a ZrN and ZrNx mixed crystal structure without columnar grain while the nanohardness and elastic modulus of the films decrease. All the ZrN coated samples show a higher corrosion resistance than that of the bare M2 steel substrate in 3.5% NaCl electrolyte. The nanohardness and elastic modulus mostly depend on the crystalline structure and Tc of ZrN(111). 展开更多
关键词 inductively coupled plasma icp magnetron sputtering zirconium nitride nficrostructure nano-hardness corrosion resistance
下载PDF
Determination of micro yttrium in an ytterbium matrix by inductively coupled plasma atomic emission spectrometry and wavelet transform 被引量:2
5
作者 MAXiaoguo 《Rare Metals》 SCIE EI CAS CSCD 2005年第2期137-141,共5页
In the determination of trace yttrium (Y) in an ytterbium (Yb) matrix byinductively coupled plasma atomic emission spectrometry (ICP-AES), the most prominent line ofyttrium, Y 371.030 nm line, suffers from strong inte... In the determination of trace yttrium (Y) in an ytterbium (Yb) matrix byinductively coupled plasma atomic emission spectrometry (ICP-AES), the most prominent line ofyttrium, Y 371.030 nm line, suffers from strong interference due to an emission line of ytterbium.In mis work, a method based on wavelet transform was proposed for the spectral interferencecorrection. Haar wavelet was selected as the mother wavelet. The discrete detail after the thirddecomposition, D3, was chosen for quantitative analysis based on the consideration of bothseparation degree and peak height. The linear correlation coefficient between the height of the leftpositive peak in D3 and the concentration of Y was calculated to be 0.9926. Six synthetic sampleswere analyzed, and the recovery for yttrium varied from 96.3 percent to 110.0 percent. The amountsof yttrium in three ytterbium metal samples were determined by the proposed approach with an averagerelative standard deviation (RSD) of 2.5 percent, and the detection limit for yttrium was 0.016percent. This novel correction technique is fast and convenient, since neither complicated modelassumption nor time-consuming iteration is required. Furthermore, it is not affected by thewavelength drift inherent in monochromators that will severely reduce the accuracy of resultsobtained by some chemometric methods. 展开更多
关键词 analytical chemistry trace analysis inductively coupled plasma atomicemission spectrometry (icp-AES) wavelet transform spectral interference correction YTTRIUM YTTERBIUM
下载PDF
Effectiveness of Radiofrequency Inductively Coupled Plasma Sources for Space Propulsion 被引量:1
6
作者 V. A. Riaby P E. Masherov +1 位作者 V. A. Obukhov V. P. Savinov 《高电压技术》 EI CAS CSCD 北大核心 2013年第9期2077-2088,共12页
Evolution of geometric forms of antenna coils for radiofrequency(RF)inductively coupled plasma(ICP)sources is analyzed.Top effectiveness of flat ICPSs generating plasma"tablet"is shown.Especially effective a... Evolution of geometric forms of antenna coils for radiofrequency(RF)inductively coupled plasma(ICP)sources is analyzed.Top effectiveness of flat ICPSs generating plasma"tablet"is shown.Especially effective are ICPSs using antenna coils enhanced with ferromagnetic cores(FMICPS).It is found that the design of flat ICPSs is simpler and more convenient for the arrangement of plasma diagnostics in comparison with ICPSs of other geometries.Effective flat FMICPS models of different diameters ranging from 10 cm to 100cm are considered.Recommendations are given for development engineers dealing with ICPS devices in general and with radio frequency ion thrusters(RITs)in particular. 展开更多
关键词 电感耦合等离子体 等离子体源 空间推进 射频 等离子体诊断 几何形式 icpS 离子推进器
下载PDF
Speciation of Volatile Selenium Species in Plants Using Gas Chromatography/Inductively Coupled Plasma Mass Spectrometry 被引量:1
7
作者 Juris MEIJA Maria MONTES-BAYN +2 位作者 Joseph A CARUSO Danika L LEDUC Norman TERRY 《色谱》 CAS CSCD 北大核心 2004年第1期16-19,共4页
Gas chromatography/inductively coupled plasma mass spectrometry (GC/ICP-MS) coupled with solid phase micro-extraction can provide a simple, extremely selective and sensitive technique for the analysis of volatile sulf... Gas chromatography/inductively coupled plasma mass spectrometry (GC/ICP-MS) coupled with solid phase micro-extraction can provide a simple, extremely selective and sensitive technique for the analysis of volatile sulfur and selenium compounds in the headspace of growing plants. In this work, the technique was used to evaluate the volatilization of selenium in wild-type and genetically-modified Brassica juncea seedlings. By converting toxic inorganic selenium in the soil to less toxic, volatile organic selenium, B. juncea might be useful in bioremediation of selenium contaminated soil. 展开更多
关键词 植物 挥发性硒化合物 含量测定 气相色谱法 电感耦合等离子体质谱法
下载PDF
Microstructure and Mechanical Properties of CrN Films Deposited by Inductively Coupled Plasma Enhanced Radio Frequency Magnetron Sputtering
8
作者 刘峰 孟月东 +1 位作者 任兆杏 舒兴胜 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第3期340-343,共4页
CrN films have been synthesized on Si(100) wafer by inductively coupled plasma (ICP)-enhanced radio frequency (RF) magnetron sputtering. The effects of ICP power on microstructure, crystal orientation, nanohardn... CrN films have been synthesized on Si(100) wafer by inductively coupled plasma (ICP)-enhanced radio frequency (RF) magnetron sputtering. The effects of ICP power on microstructure, crystal orientation, nanohardness and stress of the CrN films have been investigated. With the increase of ICP power, the current density at substrate increases and the films exhibit denser structure, while the DC self-bias of target and the deposition rate of films decrease. The films change from crystal structure to amorphous structure with the increase of ICP power. The measured nanohardness and the compressive stress of films reach the topmost at ICP power of 150 W and 200 W, respectively. The mechanical properties of films show strong dependence on the crystalline structure and the density influenced by the ICP power. 展开更多
关键词 inductively coupled plasma icp RF magnetron sputtering CRN MICROSTRUCTURE nanohardness STRESS
下载PDF
Influence of a centered dielectric tube on inductively coupled plasma source: Chamber structures and plasma characteristics
9
作者 毕振华 洪义 +3 位作者 雷光玖 王帅 王友年 刘东平 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第7期250-255,共6页
A high-density RF ion source is an essential part of a neutral beam injector. In this study, the authors attempt to retrofit an original regular RF ion source reactor by inserting a thin dielectric tube through the sy... A high-density RF ion source is an essential part of a neutral beam injector. In this study, the authors attempt to retrofit an original regular RF ion source reactor by inserting a thin dielectric tube through the symmetric axis of the discharge chamber. With the aid of this inner tube, the reactor is capable of generating a radial magnetic field instead of the original transverse magnetic field, which solves the E × B drift problem in the current RF ion source structure. To study the disturbance of the dielectric tube, a fluid model is introduced to study the plasma parameters with or without the internal dielectric tube, based on the inductively coupled plasma(ICP) reactor. The simulation results show that while introducing the internal dielectric tube into the ICP reactor, both the plasma density and plasma potential have minor influence during the discharge process, and there is good uniformity at the extraction region. The influence of the control parameters reveals that the plasma densities at the extraction region decrease first and subsequently slow down while enhancing the diffusion region. 展开更多
关键词 neutral beam ion source inductively coupled plasmaicp fluid model
下载PDF
Inductively Coupling Plasma(ICP) Treatment of Propylene(PP) Surface and Adhesion Improvement
10
作者 刘彦君 傅彦培 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第6期704-708,共5页
Study on increasing the roughness of the polymer substrate surface to enhance the adhesion with the copper layer in an inductively coupling plasma (ICP) process was carried out. The microstructure of the polymer sub... Study on increasing the roughness of the polymer substrate surface to enhance the adhesion with the copper layer in an inductively coupling plasma (ICP) process was carried out. The microstructure of the polymer substrate surfaces, which were exposed to different kinds of plasma treatment, was identified by scanning electron microscopy(SEM) analysis, peel strength of the copper coating and water surface contact angle. The adhesion of the substrate was largely enhanced by plasma treatment and the copper deposited coating reached a value of 7.68 kgf/m in verifying the adhesion of the copper coating with polymer material. The quality of the line/space 50/50 μm produced in the laboratory was examined by the pressure cooker test and proved to meet the requirement. 展开更多
关键词 inductively coupling plasma icp water contact angle peel strength
下载PDF
Time-resolved radial uniformity of pulse-modulated inductively coupled O_(2)/Ar plasmas
11
作者 Wei Liu Chan Xue +3 位作者 Fei Gao Yong-Xin Liu You-Nian Wang Yong-Tao Zhao 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第6期401-408,共8页
Time-resolved radial uniformity of pulse-modulated inductively coupled O_(2)/Ar plasma has been investigated by means of a Langmuir probe as well as an optical probe in this paper. The radial uniformity of plasma has ... Time-resolved radial uniformity of pulse-modulated inductively coupled O_(2)/Ar plasma has been investigated by means of a Langmuir probe as well as an optical probe in this paper. The radial uniformity of plasma has been discussed through analyzing the nonuniformity factor β(calculated by the measured n_e, lower β means higher plasma radial uniformity). The results show that during the active-glow period, the radial distribution of ne exhibits an almost flat profile at the beginning phase, but it converts into a parabola-like profile during the steady state. The consequent evolution for β is that when the power is turned on, it declines to a minimum at first, and then it increases to a maximum, after that, it decays until it keeps constant. This phenomenon can be explained by the fact that the ionization gradually becomes stronger at the plasma center and meanwhile the rebuilt electric field(plasma potential and ambipolar potential) will confine the electrons at the plasma center as well. Besides, the mean electron energy( <ε>_(on)) at the pulse beginning decreases with the increasing duty cycle. This will postpone the plasma ignition after the power is turned on. This phenomenon has been verified by the emission intensity of Ar(λ = 750.4 nm). During the after-glow period, it is interesting to find that the electrons have a large depletion rate at the plasma center. Consequently, ne forms a hollow distribution in the radial direction at the late stage of after-glow. Therefore, β exhibits a maximum at the same time. This can be attributed to the formation of negative oxygen ion(O^(-)) at the plasma center when the power has been turned off. 展开更多
关键词 plasma radial uniformity pulse-modulated discharge inductively coupled plasma Langmuir probe
下载PDF
Quasi-delta negative ions density of Ar/O_(2)inductively coupled plasma at very low electronegativity
12
作者 Shu-Xia Zhao 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第5期460-483,共24页
One of the novel phenomena of Ar/O_(2)inductively coupled plasma,the delta negative ions density profile is discovered by the fluid simulation at very low electronegativity.The anions delta is found to be formed by th... One of the novel phenomena of Ar/O_(2)inductively coupled plasma,the delta negative ions density profile is discovered by the fluid simulation at very low electronegativity.The anions delta is found to be formed by the collaboration of successive plasma transport phases.The plasma transport itself is affected by the delta,exhibiting many new phenomena.A new type of Helmholtz equation is devised to mathematically explain the delta forming mechanism.For revealing the physics behind,a revised spring oscillator dynamic equation has been constructed according to the Helmholtz equation,in a relevant paper[Zhao S X and Li J Z(2021)Chin.Phys.B 30055202].The investigation about the anions delta distribution is a nice prediction of new phenomenon in low temperature electronegative plasmas,waiting for the validation of related experiments. 展开更多
关键词 inductively coupled plasma Ar/O_(2)discharge very low electronegativity delta distribution of anions
下载PDF
Uncertainty Evaluation of Simultaneous Determination of Lead, Cadmium and Arsenic in Cosmetics by Inductively Coupled Plasma Mass Spectrometry 被引量:1
13
作者 Cui Xiaojiao Wang Hui +3 位作者 Zhou Peng Zhou Tanchun Cao Xiongjie Hu Yuge 《China Detergent & Cosmetics》 2020年第1期68-74,共7页
This study aimed to evaluate the uncertainty of simultaneous determination of lead(Pb),cadmium(Cd)and arsenic(As)in cosmetics by microwave digestion-inductively coupled plasma mass spectrometry(ICP-MS)with ^72Ge,^115I... This study aimed to evaluate the uncertainty of simultaneous determination of lead(Pb),cadmium(Cd)and arsenic(As)in cosmetics by microwave digestion-inductively coupled plasma mass spectrometry(ICP-MS)with ^72Ge,^115In and ^209Bi as internal standards.According to the method of Safety and Technical Standards for Cosmetics(2015),a mathematical model was established to evaluate the sources and components of uncertainty for the determination of lead,cadmium and arsenic in cosmetics.The results showed that the uncertainties in the determination of lead,cadmium,and arsenic elements in cosmetics were(10.1±0.6)mg/kg,k=2,(4.84±0.28)mg/kg,k=2,(2.04±0.18)mg/kg,k=2,respectively.The main factors that affect the uncertainty of determination results were standard substance,calibration curve,recovery and measurement repeatability. 展开更多
关键词 COSMETICS uncertainty inductively coupled plasma mass spectrometry(icp-MS) heavy metals
下载PDF
<i>In Situ</i>Analysis of Copper Alloys by Femtosecond Laser Ablation Inductively Coupled Plasma Mass Spectrometry: Constrains on Matrix Effects
14
作者 Germán Velásquez Anastassia Y. Borisova +1 位作者 Sandrine Baron Luc Robbiola 《American Journal of Analytical Chemistry》 2018年第3期150-161,共12页
Direct analysis of copper-base alloys using laser ablation techniques is an increasingly common procedure in cultural heritage studies. However, main discussions remain focused on the possibility of using non-matrix m... Direct analysis of copper-base alloys using laser ablation techniques is an increasingly common procedure in cultural heritage studies. However, main discussions remain focused on the possibility of using non-matrix matched external reference materials. To evaluate the occurrence of matrix effects during in situ microanalysis of copper-base materials, using near infrared femtosecond laser ablation techniques (NIR fs-LA-ICP-MS), two bronzes, i.e., (Sn-Zn)-ternary and (Sn)-binary copper-matrix reference materials, as well as a reference synthetic glass (NIST-SRM-610) have been analyzed. The results have been compared to data obtained on a sulfide-matrix reference material. Similar values in relative sensitivity averages of 63Cu, 118Sn and 66Zn, as well as in 118Sn/63Cu and 66Zn/63Cu ratios were obtained, for all analyzed matrix types, i.e., copper-base-, silicate-, and sulfide-reference materials. Consequently, it is possible to determinate major and minor element concentrations in copper alloys, i.e., Cu, Sn and Zn, using silicate and sulfide reference materials as external calibrators, without any matrix effect and over a wide range of concentrations (from wt.% to ppm). Equally, Cu, Sn and Zn concentrations can be precisely determined in sulfides using homogeneous alloys (reference) materials as an external calibrator. Thus, it is possible to determine Cu, Sn and Zn in copper-base materials and their ore minerals, mostly sulfides, in a single analytical session, without requiring specific external calibrators for each matrix type. In contrast, immiscible elements in copper matrix, such as Pb and Fe show notable differences in their relative sensitivity values and ratios for different matrix-materials analyzed, implying that matrix-matched external calibrations remain to be applied for their trace quantification. 展开更多
关键词 Copper Alloys Reference Material Matrix Effect In-Situ Metal Determinations NEAR-INFRARED Femtosecond Laser Ablation-inductively coupled plasma-Mass SPECTROMETRY (NIR fs-LA-icp-MS)
下载PDF
基于破乳诱导萃取和ICP-MS/MS分析渣油中的微量金属元素 被引量:1
15
作者 朱乾华 刘宏伟 聂西度 《石油学报(石油加工)》 EI CAS CSCD 北大核心 2024年第1期229-238,共10页
基于破乳诱导萃取提出利用电感耦合等离子体串联质谱(ICP-MS/MS)测定渣油中多种金属元素的新策略。渣油样品经二甲苯稀释降低黏度后采用质量分数6%的Triton X-114乳化,超声水浴破乳25 min,利用体积分数40%的盐酸萃取渣油中金属元素至水... 基于破乳诱导萃取提出利用电感耦合等离子体串联质谱(ICP-MS/MS)测定渣油中多种金属元素的新策略。渣油样品经二甲苯稀释降低黏度后采用质量分数6%的Triton X-114乳化,超声水浴破乳25 min,利用体积分数40%的盐酸萃取渣油中金属元素至水相,采用ICP-MS/MS测定其中10种金属元素Na、Mg、Al、Ca、V、Cr、Fe、Ni、Cu、Zn的含量。详细评估了破乳诱导萃取条件对渣油中金属元素萃取效率的影响,在串联质谱(MS/MS)模式下,利用氦碰撞气或不同反应气消除了金属元素的质谱干扰,采用标准参考物质NIST SRM 1634c(燃油中的微量元素)验证了方法的准确性,以微波消解技术处理渣油样品并采用扇形磁场电感耦合等离子体质谱(SF-ICP-MS)进行对比分析验证了方法的可靠性。结果显示,金属元素在各自的含量范围内呈现良好的线性关系(线性相关系数≥0.9997),检出限(LOD)为2.05~31.4 ng/L,NIST SRM 1634c的测定结果与标准参考物质提供的认证值及文献报道的参考值基本一致,置信度水平达到95%,ICP-MS/MS方法与SF-ICP-MS的对比分析结果无显著性差异。所建立的ICP-MS/MS方法操作简单,分析速率快,准确可靠性好,已用于渣油中多种金属元素的质量评价。 展开更多
关键词 渣油 电感耦合等离子体串联质谱(icp-MS/MS) 金属元素 破乳诱导萃取 质谱干扰
下载PDF
电感耦合等离子体原子发射光谱(ICP-AES)法测定真空精炼镁合金物料中铁、铜、镍 被引量:1
16
作者 孙洪飞 王立鹏 +5 位作者 李蕊 唐飞龙 杨柒梅 伍秋云 田阳 吴鉴 《中国无机分析化学》 CAS 北大核心 2024年第4期464-472,共9页
真空精炼是目前镁金属提纯的重要工艺,工艺原料及真空精炼提纯镁金属过程残留物中Fe、Cu、Ni含量的准确测定对工艺参数的优化及调整具有重要的指导作用。传统测定方法中以邻二氮杂菲分光光度法、新亚铜灵分光光度法、丁二酮肟分光光度... 真空精炼是目前镁金属提纯的重要工艺,工艺原料及真空精炼提纯镁金属过程残留物中Fe、Cu、Ni含量的准确测定对工艺参数的优化及调整具有重要的指导作用。传统测定方法中以邻二氮杂菲分光光度法、新亚铜灵分光光度法、丁二酮肟分光光度法测定三种元素含量,结果准确,但操作繁琐,周期较长,难以满足工业生产中高效、快速测定的需要,且方法中所需的有机萃取剂对环境污染较大。选择电感耦合等离子体发射光谱(ICP-AES)法测定真空蒸馏精炼镁合金物料中Fe、Cu、Ni,系统探究溶解酸、溶解温度、溶解时间对物料溶解和测定的影响,选择盐酸(1+1)和过氧化氢溶解体系,200℃加热条件下反应20 min为最佳消解镁合金原料条件;选择王水溶解体系,200℃加热条件下反应25 min为真空精炼残留物最佳溶解条件。并探讨ICP-AES测定过程中各元素的检出限和测定下限以及共存元素的干扰情况,建立了ICP-AES法测定真空精炼提纯镁合金物料的方法。测定结果的相对标准偏差(RSD,n=11)为Fe 5.9%~11.5%、Cu 2.6%~11.8%、Ni 3.4%~11.5%,各元素加标回收率为Fe 96.4%~102%、Cu 101%~108%、Ni 103%~105%;按照建立的方法测定镁合金原料、真空精炼残留物中的铁、铜、镍,并与国家标准方法测定结果进行对比,结果相一致。实现了ICP-AES法快速、准确测定真空蒸馏精炼镁合金物料中铁、铜、镍含量,对及时、高效、准确评估真空精炼提纯镁工艺及产品具有重要意义。 展开更多
关键词 电感耦合等离子体发射光谱法(icp-AES) 真空精炼 残留物
下载PDF
基于MC-ICP-MS的稳定铜同位素分析在环境健康研究中的应用进展 被引量:1
17
作者 王伟超 张璐瑶 +6 位作者 令伟博 陈子谷 陆达伟 杨学志 傅建捷 刘倩 江桂斌 《质谱学报》 EI CAS CSCD 北大核心 2024年第2期183-192,共10页
铜(Cu)是人体内重要的微量金属元素之一,在许多生命过程中扮演着重要角色;同时,铜在人体内受到严格调控,其稳态与人体生理状态密切相关,许多疾病的发生往往伴随着铜代谢失衡的现象。通过监测铜稳态的细微变化,可以更精准地发现导致人体... 铜(Cu)是人体内重要的微量金属元素之一,在许多生命过程中扮演着重要角色;同时,铜在人体内受到严格调控,其稳态与人体生理状态密切相关,许多疾病的发生往往伴随着铜代谢失衡的现象。通过监测铜稳态的细微变化,可以更精准地发现导致人体生理异常变化的因素,特别是环境因素对疾病发生及发展的影响。因此,稳定铜同位素分析在环境健康研究中具有广泛的应用前景。多接收器电感耦合等离子体质谱(MC-ICP-MS)是一种强大的同位素分析质谱方法,具有适用范围广、分析精度高等优点,有效促进了铜同位素分析的发展。本文综述了非传统稳定同位素分馏机理及基于MC-ICP-MS的铜同位素分析方法,总结了铜同位素分析在环境健康研究中的主要应用,并对其前景进行展望。 展开更多
关键词 稳定同位素 质谱分析 环境健康 多接收器电感耦合等离子体质谱(MC-icp-MS)
下载PDF
氧气反应模式-四极杆ICP-MS定量高温合金中痕量元素及质谱干扰消除机理研究 被引量:1
18
作者 冯媛媛 周涛 +2 位作者 唐一川 张见营 李彭辉 《质谱学报》 EI CAS CSCD 北大核心 2024年第4期531-539,I0004,共10页
本研究建立了氧气反应模式-四极杆电感耦合等离子体质谱(Q-ICP-MS)法准确定量高温合金中痕量杂质元素,对不同碰撞/反应模式消除质谱干扰的效果进行研究。结果表明,氧气动态反应池(DRC-O_(2))模式下,目标元素Cd的多原子离子质谱干扰能够... 本研究建立了氧气反应模式-四极杆电感耦合等离子体质谱(Q-ICP-MS)法准确定量高温合金中痕量杂质元素,对不同碰撞/反应模式消除质谱干扰的效果进行研究。结果表明,氧气动态反应池(DRC-O_(2))模式下,目标元素Cd的多原子离子质谱干扰能够被有效去除;在优化气流为2 mL/min时,信噪比达到最高,检出限较标准模式(STD)降低了近3个数量级。此外,还研究了质谱干扰的消除机理,发现对于元素X(X=Rb、Nb、Mo、Cs、Ta、W或U),当X-O键能大于O-O键能时,质谱干扰组分XO转化成非干扰组分XOO为自发反应,因此,O_(2)充足时更容易生成XOO,从而消除XO干扰。在此基础上,采用高浓度基体模拟溶液(Mo、Nb、Ta、W)分别对痕量Cd、Ag、Au、Hg元素测量的方法学参数进行评估,方法检出限0.08~0.31μg/g、测量重复性相对标准偏差(RSD)2.3%~3.1%(n=6),加标回收率98%~103%,并进一步使用高温合金标准物质验证了方法的可靠性。最后,对3类典型牌号高温合金样品中的痕量杂质进行测量,证明该方法的分析速度快、检出限低、准确可靠,能够满足高温合金中主量Mo、Nb、Ta、W元素存在时被干扰杂质的测量要求。 展开更多
关键词 四极杆电感耦合等离子体质谱(Q-icp-MS) 高温合金 质谱干扰 痕量元素 机理研究
下载PDF
多功能集成色谱-电感耦合等离子体质谱(ICP-MS)法快速测定饮用水中砷形态
19
作者 姜健 叶利萍 +3 位作者 王晓玮 谢继安 单晓梅 陈曦 《中国无机分析化学》 CAS 北大核心 2024年第12期1617-1623,共7页
为准确快速测定饮用水中砷形态,采用多功能集成色谱(prepFAST IC)与电感耦合等离子体质谱(ICP-MS)联用,采用ICX-As35阴离子色谱柱为分析柱,通过仪器注射器推动改变1 mmol/L碳酸铵(pH=9.7)和100 mmol/L碳酸铵(pH=9.2)洗脱液的混合比,进... 为准确快速测定饮用水中砷形态,采用多功能集成色谱(prepFAST IC)与电感耦合等离子体质谱(ICP-MS)联用,采用ICX-As35阴离子色谱柱为分析柱,通过仪器注射器推动改变1 mmol/L碳酸铵(pH=9.7)和100 mmol/L碳酸铵(pH=9.2)洗脱液的混合比,进行浓度梯度洗脱,在105 s内快速分析出甜菜碱(AsB)、亚砷酸盐[As(Ⅲ)]、二甲基砷(DMA)、砷胆碱(AsC)、一甲基砷(MMA)和砷酸盐[As(V)]六种As的形态,建立饮用水中六种砷(As)形态的多功能集成色谱串联ICP-MS分析方法。在0~100μg/L六种As的形态线性关系良好,相关系数均大于0.999,检出限为0.02~0.03μg/L。采用加标回收进行准确性评估,纯水和末梢水低、中、高浓度样本的加标回收率为89.2%~103%,不同浓度砷形态的相对标准偏差(RSD)均优于2.0%。方法灵敏度高、准确可靠、分析效率高,适用于生活饮用水中砷形态的快速测定,提高了工作效率。 展开更多
关键词 多功能集成色谱 电感耦合等离子体质谱 快速测定 砷形态 生活饮用水
下载PDF
电感耦合等离子体质谱(ICP-MS)法测定锆钛矿中的铪
20
作者 郭晓瑞 赵一帆 +3 位作者 毛香菊 王甜甜 樊蕾 肖芳 《中国无机分析化学》 北大核心 2024年第3期306-311,共6页
锆钛矿中存在耐高温的锆、钛化合物,铪以类质同象进入锆矿物中,准确测定锆钛矿中的铪对选矿研究、矿物综合利用及工业生产有重要作用。通过考察锆钛矿成分及熔融方法,以碳酸钠-硼砂高温熔融锆钛矿,以178 Hf为分析同位素及185 Re为内标,... 锆钛矿中存在耐高温的锆、钛化合物,铪以类质同象进入锆矿物中,准确测定锆钛矿中的铪对选矿研究、矿物综合利用及工业生产有重要作用。通过考察锆钛矿成分及熔融方法,以碳酸钠-硼砂高温熔融锆钛矿,以178 Hf为分析同位素及185 Re为内标,使用电感耦合等离子体质谱法测定锆钛矿中含量不均的铪。结果表明,碳酸钠-硼砂高温熔融效果最好,可完全溶解耐高温难分解的锆钛矿,当碳酸钠-硼砂质量配比为2∶1时熔融效果最佳。ICP-MS蠕动泵转速为45 r/min、雾化气流量为1.06 L/min时雾化效率最优。在选定的实验条件下,HfO_(2)质谱强度与质量浓度在0.01~250 ng/mL呈良好的线性关系,相关系数为0.9997,背景等效浓度为0.029 ng/mL,方法检出限为0.0032 ng/mL。按实验方法对中国国家标准物质中的HfO_(2)进行测定,测定值与认定值一致,相对标准偏差在1.6%~3.2%。按实验方法对锆钛矿样品中的HfO_(2)进行测定并进行加标回收实验,测定结果的相对标准偏差(RSD,n=9)为0.90%~3.4%,加标回收率在96.0%~106%,满足国家地质矿产行业标准DZ/T 0130—2006的要求。 展开更多
关键词 锆钛矿 碳酸钠-硼砂熔融法 电感耦合等离子体质谱法(icp-MS) 雾化效率
下载PDF