fouling online in an anaerobic membrane bioreac-tor(AMBR).Short-term running experiments were carried out under different operating conditions to explore feasible ultrasonic parameters.The experimental results indicat...fouling online in an anaerobic membrane bioreac-tor(AMBR).Short-term running experiments were carried out under different operating conditions to explore feasible ultrasonic parameters.The experimental results indicated that when the crossflow velocity was more than 1.0 m/s,mem-brane fouling could be controlled effectively only by hydro-dynamic methods without ultrasound.When ultrasound was applied,an ultrasonic power range of 60-150 W was suitable for the membrane fouling control in the experimental system.The experimental results showed that the membrane fouling was controlled so well that membrane filtration resistance(ΣR)could stay at 5×10^(11)m^(−1) for more than a week with the crossflow velocity of 0.75 m/s,which equaled the effect of crossflow velocity of more than 1.0 m/s without ultrasound.展开更多
Membrane fouling limits the effects of long-term stable operation of membrane bioreactor (MBR). Control of membrane fouling can extend the membrane life and reduce water treatment cost effectively. A pilot scale ano...Membrane fouling limits the effects of long-term stable operation of membrane bioreactor (MBR). Control of membrane fouling can extend the membrane life and reduce water treatment cost effectively. A pilot scale anoxic/aerobic-membrane bioreactor (A/O- MBR, 40 L/hr) was used to treat the hyperhaline municipal sewage from a processing zone of Tianjin, China. Impact factors including mixed liquid sludge suspension (MLSS), sludge viscosity (Ix), microorganisms, extracellular polymeric substances (EPS), aeration intensity and suction/suspended time on membrane fouling and pollution control were studied. The relationships among various factors associated with membrane fouling were analyzed. Results showed that there was a positive correlation among MLSS, sludge viscosity and trans-membrane pressure (TMP). Considering water treatment efficiency and stable operation of the membrane module, MLSS of 5 g/L was suggested for the process. There was a same trend among EPS, sludge viscosity and TMP. Numbers and species of microorganisms affected membrane fouling. Either too high or too low aeration intensity was not conducive to membrane fouling control. Aeration intensity of 1.0 m3/hr (gas/water ratio of 25:1) is suggested for the process. A long suction time caused a rapid increase in membrane resistance. However, long suspended time cannot prevent the increase of membrane resistance effectively even though a suspended time was necessary for scale off particles from the membrane surface. The suction/suspended time of 12 min/3 rain was selected for the process. The interaction of various environmental factors and operation conditions must be considered synthetically.展开更多
基金This work was supported by the National High-Tech Research and Development(863)Program of China(Grant No.2002AA601220)。
文摘fouling online in an anaerobic membrane bioreac-tor(AMBR).Short-term running experiments were carried out under different operating conditions to explore feasible ultrasonic parameters.The experimental results indicated that when the crossflow velocity was more than 1.0 m/s,mem-brane fouling could be controlled effectively only by hydro-dynamic methods without ultrasound.When ultrasound was applied,an ultrasonic power range of 60-150 W was suitable for the membrane fouling control in the experimental system.The experimental results showed that the membrane fouling was controlled so well that membrane filtration resistance(ΣR)could stay at 5×10^(11)m^(−1) for more than a week with the crossflow velocity of 0.75 m/s,which equaled the effect of crossflow velocity of more than 1.0 m/s without ultrasound.
基金supported by the Special Projects of Major National Science and Technology of China (No. 2008ZX07314-003)the National Natural Science Foundation of China (No. 50708063)
文摘Membrane fouling limits the effects of long-term stable operation of membrane bioreactor (MBR). Control of membrane fouling can extend the membrane life and reduce water treatment cost effectively. A pilot scale anoxic/aerobic-membrane bioreactor (A/O- MBR, 40 L/hr) was used to treat the hyperhaline municipal sewage from a processing zone of Tianjin, China. Impact factors including mixed liquid sludge suspension (MLSS), sludge viscosity (Ix), microorganisms, extracellular polymeric substances (EPS), aeration intensity and suction/suspended time on membrane fouling and pollution control were studied. The relationships among various factors associated with membrane fouling were analyzed. Results showed that there was a positive correlation among MLSS, sludge viscosity and trans-membrane pressure (TMP). Considering water treatment efficiency and stable operation of the membrane module, MLSS of 5 g/L was suggested for the process. There was a same trend among EPS, sludge viscosity and TMP. Numbers and species of microorganisms affected membrane fouling. Either too high or too low aeration intensity was not conducive to membrane fouling control. Aeration intensity of 1.0 m3/hr (gas/water ratio of 25:1) is suggested for the process. A long suction time caused a rapid increase in membrane resistance. However, long suspended time cannot prevent the increase of membrane resistance effectively even though a suspended time was necessary for scale off particles from the membrane surface. The suction/suspended time of 12 min/3 rain was selected for the process. The interaction of various environmental factors and operation conditions must be considered synthetically.