Multi-terminal hybrid high-voltage direct current(HVDC)systems have been developed quickly in recent years in power transmission area.However,for voltage-source converter(VSC)stations in hybrid HVDC systems,no direct ...Multi-terminal hybrid high-voltage direct current(HVDC)systems have been developed quickly in recent years in power transmission area.However,for voltage-source converter(VSC)stations in hybrid HVDC systems,no direct current(DC)filters are required.In addition,the DC reactor is also not installed at the line end because the DC fault can be limited by the converter itself.This means that the boundary element at the line end is absent,and the single-ended protections used in line commutated converter(LCC)based HVDC(LCC-HVDC)systems or VSC-HVDC systems cannot distinguish the fault line in multi-terminal hybrid HVDC systems.This paper proposes a novel singleended DC protection strategy suitable for the multi-terminal hybrid HVDC system,which mainly applies the transient information and active injection concept to detect and distinguish the fault line.Compared with the single-ended protections used in LCC-HVDC and VSC-HVDC systems,the proposed protection strategy is not dependent on the line boundary element and is thus suitable for the multiterminal hybrid HVDC system.The corresponding simulation cases based on power systems computer aided design(PSCAD)/electromagnetic transients including DC(EMTDC)are carried out to verify the superiority of the proposed protection.展开更多
The hybrid dc circuit breaker(HCB)has the advantages of fast action speed and low operating loss,which is an idealmethod for fault isolation ofmulti-terminal dc grids.Formulti-terminal dc grids that transmit power thr...The hybrid dc circuit breaker(HCB)has the advantages of fast action speed and low operating loss,which is an idealmethod for fault isolation ofmulti-terminal dc grids.Formulti-terminal dc grids that transmit power through overhead lines,HCBs are required to have reclosing capability due to the high fault probability and the fact that most of the faults are temporary faults.To avoid the secondary fault strike and equipment damage that may be caused by the reclosing of the HCB when the permanent fault occurs,an adaptive reclosing scheme based on traveling wave injection is proposed in this paper.The scheme injects traveling wave signal into the fault dc line through the additionally configured auxiliary discharge branch in the HCB,and then uses the reflection characteristic of the traveling wave signal on the dc line to identify temporary and permanent faults,to be able to realize fast reclosing when the temporary fault occurs and reliably avoid reclosing after the permanent fault occurs.The test results in the simulation model of the four-terminal dc grid show that the proposed adaptive reclosing scheme can quickly and reliably identify temporary and permanent faults,greatly shorten the power outage time of temporary faults.In addition,it has the advantages of easiness to implement,high reliability,robustness to high-resistance fault and no dead zone,etc.展开更多
Security constrained multi area multi objective dynamic economic dispatch (SCMAMODED) with renewable energy (RE) and all the possible MTDC stability constraints is formulated for the first time. The stability merits o...Security constrained multi area multi objective dynamic economic dispatch (SCMAMODED) with renewable energy (RE) and all the possible MTDC stability constraints is formulated for the first time. The stability merits of multi terminal DC (MTDC) tie lines as compared to the traditional HVAC forms the main objective of this paper. Probabilistic load flow (PLF) is applied to determine the system parameters while the uncertainties are modelled using Scenario Based Method (SBM). The simulation results reveal that with the use of MTDC tie lines, the frequency and voltage stability in the MAMODED with renewable energy sources (RES) are enhanced while keeping the MTDC power exchange interface nodes at secure levels.展开更多
This paper introduces the characteristics of VSC and MMC-MTDC and discusses the effects of different kinds of faults in HVDC systems. Special attention is given to the comparison between a pole-to-pole fault and a pol...This paper introduces the characteristics of VSC and MMC-MTDC and discusses the effects of different kinds of faults in HVDC systems. Special attention is given to the comparison between a pole-to-pole fault and a pole-to-ground fault occurring in the middle of the line or at the terminal of a VSC. Simulations using MATLAB are provided in this article which show the difference effects clearly when faults occur in a VSC-MTDC system or in a MMC-MTDC system. Understanding of such fault characteristics and the influence of the control system on them are important prerequisites on the way to MTDC systems.展开更多
基于移相加占空比控制策略的三有源桥TAB(triple active bridge)DC-DC变换器具有效率高和软开关范围可扩展等优点,但其小信号建模过程复杂、闭环控制环路参数整定困难。针对该问题,提出1种TAB工作在移相加占空比控制下的全阶连续广义状...基于移相加占空比控制策略的三有源桥TAB(triple active bridge)DC-DC变换器具有效率高和软开关范围可扩展等优点,但其小信号建模过程复杂、闭环控制环路参数整定困难。针对该问题,提出1种TAB工作在移相加占空比控制下的全阶连续广义状态平均建模和PI控制器设计方法。首先,分析TAB的运行原理和Y型等效结构;然后,结合移相加占空比控制的特点和交流方波源等效方法,推导出TAB的广义状态空间平均模型;接着,在推得模型的基础上求得输入到输出的传递函数,设计出PI控制器参数。最后,结合数字仿真及样机实验验证了所提方法的正确性及有效性。展开更多
由于DCS控制器中电表传感器在计量检测过程中,传统的B-MAC-DCS协议能耗和丢包率较高,无法缓解汇聚节点的漏斗效应,导致在远程抄表过程中传感器计量误差增大。提出一种机械电表接触传感器计量误差检测方法。采用小波基函数对DCS控制器中...由于DCS控制器中电表传感器在计量检测过程中,传统的B-MAC-DCS协议能耗和丢包率较高,无法缓解汇聚节点的漏斗效应,导致在远程抄表过程中传感器计量误差增大。提出一种机械电表接触传感器计量误差检测方法。采用小波基函数对DCS控制器中的接触传感器计量数据抗干扰处理,并通过动态选取阈值的方法,对经过小波变换后的数据去除噪声。使用低功耗自适应集簇分层型(low energy adaptive clustering hierarchy,LEACH)协议分簇代替传统的B-MAC协议;根据簇内监测值,引入阈值分析方法获取传感器计量指标,并将其作为判定依据进行误差检测,根据计量指标的变化情况判断是否存在计量误差。实验结果表明,所提方法可以准确且有效检测出机械电表接触传感器计量误差,解决DCS中机械电表的运行隐患问题。展开更多
文摘Multi-terminal hybrid high-voltage direct current(HVDC)systems have been developed quickly in recent years in power transmission area.However,for voltage-source converter(VSC)stations in hybrid HVDC systems,no direct current(DC)filters are required.In addition,the DC reactor is also not installed at the line end because the DC fault can be limited by the converter itself.This means that the boundary element at the line end is absent,and the single-ended protections used in line commutated converter(LCC)based HVDC(LCC-HVDC)systems or VSC-HVDC systems cannot distinguish the fault line in multi-terminal hybrid HVDC systems.This paper proposes a novel singleended DC protection strategy suitable for the multi-terminal hybrid HVDC system,which mainly applies the transient information and active injection concept to detect and distinguish the fault line.Compared with the single-ended protections used in LCC-HVDC and VSC-HVDC systems,the proposed protection strategy is not dependent on the line boundary element and is thus suitable for the multiterminal hybrid HVDC system.The corresponding simulation cases based on power systems computer aided design(PSCAD)/electromagnetic transients including DC(EMTDC)are carried out to verify the superiority of the proposed protection.
基金supported by the Science and Technology Project of State Grid Corporation of China under Grant 520201210025。
文摘The hybrid dc circuit breaker(HCB)has the advantages of fast action speed and low operating loss,which is an idealmethod for fault isolation ofmulti-terminal dc grids.Formulti-terminal dc grids that transmit power through overhead lines,HCBs are required to have reclosing capability due to the high fault probability and the fact that most of the faults are temporary faults.To avoid the secondary fault strike and equipment damage that may be caused by the reclosing of the HCB when the permanent fault occurs,an adaptive reclosing scheme based on traveling wave injection is proposed in this paper.The scheme injects traveling wave signal into the fault dc line through the additionally configured auxiliary discharge branch in the HCB,and then uses the reflection characteristic of the traveling wave signal on the dc line to identify temporary and permanent faults,to be able to realize fast reclosing when the temporary fault occurs and reliably avoid reclosing after the permanent fault occurs.The test results in the simulation model of the four-terminal dc grid show that the proposed adaptive reclosing scheme can quickly and reliably identify temporary and permanent faults,greatly shorten the power outage time of temporary faults.In addition,it has the advantages of easiness to implement,high reliability,robustness to high-resistance fault and no dead zone,etc.
文摘Security constrained multi area multi objective dynamic economic dispatch (SCMAMODED) with renewable energy (RE) and all the possible MTDC stability constraints is formulated for the first time. The stability merits of multi terminal DC (MTDC) tie lines as compared to the traditional HVAC forms the main objective of this paper. Probabilistic load flow (PLF) is applied to determine the system parameters while the uncertainties are modelled using Scenario Based Method (SBM). The simulation results reveal that with the use of MTDC tie lines, the frequency and voltage stability in the MAMODED with renewable energy sources (RES) are enhanced while keeping the MTDC power exchange interface nodes at secure levels.
文摘This paper introduces the characteristics of VSC and MMC-MTDC and discusses the effects of different kinds of faults in HVDC systems. Special attention is given to the comparison between a pole-to-pole fault and a pole-to-ground fault occurring in the middle of the line or at the terminal of a VSC. Simulations using MATLAB are provided in this article which show the difference effects clearly when faults occur in a VSC-MTDC system or in a MMC-MTDC system. Understanding of such fault characteristics and the influence of the control system on them are important prerequisites on the way to MTDC systems.
文摘基于移相加占空比控制策略的三有源桥TAB(triple active bridge)DC-DC变换器具有效率高和软开关范围可扩展等优点,但其小信号建模过程复杂、闭环控制环路参数整定困难。针对该问题,提出1种TAB工作在移相加占空比控制下的全阶连续广义状态平均建模和PI控制器设计方法。首先,分析TAB的运行原理和Y型等效结构;然后,结合移相加占空比控制的特点和交流方波源等效方法,推导出TAB的广义状态空间平均模型;接着,在推得模型的基础上求得输入到输出的传递函数,设计出PI控制器参数。最后,结合数字仿真及样机实验验证了所提方法的正确性及有效性。
文摘由于DCS控制器中电表传感器在计量检测过程中,传统的B-MAC-DCS协议能耗和丢包率较高,无法缓解汇聚节点的漏斗效应,导致在远程抄表过程中传感器计量误差增大。提出一种机械电表接触传感器计量误差检测方法。采用小波基函数对DCS控制器中的接触传感器计量数据抗干扰处理,并通过动态选取阈值的方法,对经过小波变换后的数据去除噪声。使用低功耗自适应集簇分层型(low energy adaptive clustering hierarchy,LEACH)协议分簇代替传统的B-MAC协议;根据簇内监测值,引入阈值分析方法获取传感器计量指标,并将其作为判定依据进行误差检测,根据计量指标的变化情况判断是否存在计量误差。实验结果表明,所提方法可以准确且有效检测出机械电表接触传感器计量误差,解决DCS中机械电表的运行隐患问题。