Here, we administered repeated-pulse transcranial magnetic stimulation to healthy people at the left Guangming (GB37) and a mock point, and calculated the sample entropy of electroencephalo- gram signals using nonli...Here, we administered repeated-pulse transcranial magnetic stimulation to healthy people at the left Guangming (GB37) and a mock point, and calculated the sample entropy of electroencephalo- gram signals using nonlinear dynamics. Additionally, we compared electroencephalogram sample entropy of signals in response to visual stimulation before, during, and after repeated-pulse tran- scranial magnetic stimulation at the Guangming. Results showed that electroencephalogram sample entropy at left (F3) and right (FP2) frontal electrodes were significantly different depending on where the magnetic stimulation was administered. Additionally, compared with the mock point, electroencephalogram sample entropy was higher after stimulating the Guangming point. When visual stimulation at Guangming was given before repeated-pulse transcranial magnetic stimula- tion, significant differences in sample entropy were found at five electrodes (C3, Cz, C4, P3, T8) in parietal cortex, the central gyrus, and the right temporal region compared with when it was given after repeated-pulse transcranial magnetic stimulation, indicating that repeated-pulse transcranial magnetic stimulation at Guangming can affect visual function. Analysis of electroencephalogram revealed that when visual stimulation preceded repeated pulse transcranial magnetic stimulation, sample entropy values were higher at the C3, C4, and P3 electrodes and lower at the Cz and T8 electrodes than visual stimulation followed preceded repeated pulse transcranial magnetic stimula- tion. The findings indicate that repeated-pulse transcranial magnetic stimulation at the Guangming evokes different patterns of electroencephalogram signals than repeated-pulse transcranial mag- netic stimulation at other nearby points on the body surface, and that repeated-pulse transcranial magnetic stimulation at the Guangrning is associated with changes in the complexity of visually evoked electroencephalogram signals in parietal regions, central gyrus, and temporal regions.展开更多
Objective: To study the expression of CA125 in the serum of patients with CHF and the relationship between CA125 level and the occurrence of adverse cardiovascular events. Methods: The clinical data of 132 patients wi...Objective: To study the expression of CA125 in the serum of patients with CHF and the relationship between CA125 level and the occurrence of adverse cardiovascular events. Methods: The clinical data of 132 patients with CHF admitted to Shizuishan Second People’s Hospital from January 2023 to December 2023 were collected and divided into heart function II group, heart function III group, heart function IV group according to cardiac function. 44 healthy subjects who underwent physical examination during the same period were selected as the control group. The clinical data of CA125, NT-proBNP, echocardiography and other clinical data of the four groups were compared, and the incidence of major adverse cardiovascular events was followed up for 12 months. Results: Compared with the control group, the CA125 level in the CHF group was significantly increased (P Conclusion: Serum CA125 level is related to the cardiac function level in CHF patients and increases with the deterioration of cardiac function. The increase of the index is related to the mortality rate and re-hospitalization rate, suggesting that CA125 can be used as an indicator to reflect the severity of heart failure and prognosis monitoring.展开更多
基金supported by the National Natural Science Foundation of China,No.31100711,51377045,31300818the Natural Science Foundation of Hebei Province,No.H2013202176
文摘Here, we administered repeated-pulse transcranial magnetic stimulation to healthy people at the left Guangming (GB37) and a mock point, and calculated the sample entropy of electroencephalo- gram signals using nonlinear dynamics. Additionally, we compared electroencephalogram sample entropy of signals in response to visual stimulation before, during, and after repeated-pulse tran- scranial magnetic stimulation at the Guangming. Results showed that electroencephalogram sample entropy at left (F3) and right (FP2) frontal electrodes were significantly different depending on where the magnetic stimulation was administered. Additionally, compared with the mock point, electroencephalogram sample entropy was higher after stimulating the Guangming point. When visual stimulation at Guangming was given before repeated-pulse transcranial magnetic stimula- tion, significant differences in sample entropy were found at five electrodes (C3, Cz, C4, P3, T8) in parietal cortex, the central gyrus, and the right temporal region compared with when it was given after repeated-pulse transcranial magnetic stimulation, indicating that repeated-pulse transcranial magnetic stimulation at Guangming can affect visual function. Analysis of electroencephalogram revealed that when visual stimulation preceded repeated pulse transcranial magnetic stimulation, sample entropy values were higher at the C3, C4, and P3 electrodes and lower at the Cz and T8 electrodes than visual stimulation followed preceded repeated pulse transcranial magnetic stimula- tion. The findings indicate that repeated-pulse transcranial magnetic stimulation at the Guangming evokes different patterns of electroencephalogram signals than repeated-pulse transcranial mag- netic stimulation at other nearby points on the body surface, and that repeated-pulse transcranial magnetic stimulation at the Guangrning is associated with changes in the complexity of visually evoked electroencephalogram signals in parietal regions, central gyrus, and temporal regions.
文摘Objective: To study the expression of CA125 in the serum of patients with CHF and the relationship between CA125 level and the occurrence of adverse cardiovascular events. Methods: The clinical data of 132 patients with CHF admitted to Shizuishan Second People’s Hospital from January 2023 to December 2023 were collected and divided into heart function II group, heart function III group, heart function IV group according to cardiac function. 44 healthy subjects who underwent physical examination during the same period were selected as the control group. The clinical data of CA125, NT-proBNP, echocardiography and other clinical data of the four groups were compared, and the incidence of major adverse cardiovascular events was followed up for 12 months. Results: Compared with the control group, the CA125 level in the CHF group was significantly increased (P Conclusion: Serum CA125 level is related to the cardiac function level in CHF patients and increases with the deterioration of cardiac function. The increase of the index is related to the mortality rate and re-hospitalization rate, suggesting that CA125 can be used as an indicator to reflect the severity of heart failure and prognosis monitoring.