On-Line Measurement of the Chemical Oxygen Demand in Wastewater in a Pulp and Paper Mill Using Near Infrared Spectroscopy 被引量:5
1
作者 John Dahlbacka Josefina Nystrom +2 位作者 Torgny Mossing Paul Geladi Tom Lillhonga 《Spectral Analysis Review》 2014年第4期19-25,共7页
Although near infrared (NIR) spectroscopy has been evaluated for numerous applications, the number of actual on-line or even on-site industrial applications seems to be very limited. In the present paper, the attempts... Although near infrared (NIR) spectroscopy has been evaluated for numerous applications, the number of actual on-line or even on-site industrial applications seems to be very limited. In the present paper, the attempts to produce online predictions of the chemical oxygen demand (COD) in wastewater from a pulp and paper mill using NIR spectroscopy are described. The task was perceived as very challenging, but with a root mean square error of prediction of 149 mg/l, roughly corresponding to 1/10 of the studied concentration interval, this attempt was deemed as successful. This result was obtained by using partial least squares model regression, interpolated reference values for calibration purposes, and by evenly distributing the calibration data in the concentration space. This work may also represent the first industrial application of online COD measurements in wastewater using NIR spectroscopy. 展开更多
关键词 Chemical Oxygen Demand (COD) Industrial Wastewater Near Infrared Spectroscopy (NIR) Multivariate Calibration on-line measurement
下载PDF
On-line Measurement of Water-Soluble Ions in Ambient Particles 被引量:5
2
作者 温天雪 王跃思 +1 位作者 张士昱 刘广仁 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2006年第4期586-592,共7页
Combining the system of rapid collection of ambient particles and ion chromatography, the system of rapid collection of fine particles and ion chromatography (RCFP-IC) was established to automatically analyze on-lin... Combining the system of rapid collection of ambient particles and ion chromatography, the system of rapid collection of fine particles and ion chromatography (RCFP-IC) was established to automatically analyze on-line the concentrations of water-soluble ions in ambient particles. Here, the general scheme of RCFP-IC is described and its basic performance is tested. The detection limit of RCFP-IC for SO4^2-, NO3^-, NO2^-, Cl^- and F- is below 0.3μg m^-3. The collection efficiency of RCFP-IC increases rapidly with increasing sized particles. For particles larger than 300 nm, the collection efficiency approaches 100%. The precision of RCFP-IC is more than 90% over 28 repetitions. The response of RCFP-IC is very sensitive and no obvious cross-pollution is found during measurement. A comparison of RCFP-IC with an integrated filter measurement indicates that the measurement of RCFP-IC is comparable in both laboratory experiments and field observations. The results of the field experiment prove that RCFP-IC is an effective on-line monitoring system and is helpful in source apportionment and pollution episode monitoring. 展开更多
关键词 RCFP-IC water-soluble ions on-line basic performance field observation
下载PDF
A METHOD OF ON-LINE MEASUREMENT FOR THE FREQUENCY RESPONSE AND IMPULSE RESPONSE FUNCTIONS OF MULTIVARIATE SYSTEM
3
作者 汪凤泉 韩晓林 吴慧新 《Journal of Southeast University(English Edition)》 EI CAS 1993年第1期95-101,共7页
In this paper,a method of multipoint pseudorandom combined excita-tion with the orthogonal reciprocal repeated sequences(ORRS)is presented on thebackground of the on-line identification of multivariate system.The capa... In this paper,a method of multipoint pseudorandom combined excita-tion with the orthogonal reciprocal repeated sequences(ORRS)is presented on thebackground of the on-line identification of multivariate system.The capacity of therestraint to the identification error caused by the non-random D.C.drift of the mul-ti-input excitation with the ORRS in the multivariate system is also discussed.Thevalidity of the method described in this paper is proved by the modelling tests of themulti-plate rotor system. 展开更多
关键词 on-line IDENTIFICATION multi-point EXCITATION ORTHOGONAL reciprocal repeated SEQUENCE VIBRATION measurement
下载PDF
On-line measurement of electrical variables of the transducer during ultrasonic welding and cutting
4
作者 闫久春 刘井权 杨士勤 《China Welding》 EI CAS 2002年第2期133-137,共5页
A measurement system for high power electrical variables with ultrasonic frequency was established. It can measure the effective values of the voltage and the current, the active power, the phase difference of voltage... A measurement system for high power electrical variables with ultrasonic frequency was established. It can measure the effective values of the voltage and the current, the active power, the phase difference of voltage and current, the frequency of the transducer during ultrasonic welding and cutting. In sampling circuits of the system, the measured current is sensed by using a no capacitance and no inductance precision resistor and is treated with a difference amplifier, the measured voltage is processed by using a proportional amplifier. For achieving good amplitude frequency characteristics and rapid measurement of high frequency signals, the resistors, capacitors and amplifiers used in the system are rationally selected. Calibrating experiments show that relative errors are less than 1% for voltage and current effective values and less than 2.5% for active power, and absolute errors are ±1 Hz for frequency and ±1.7° for phase difference of voltage and current in the range of 17~23 kHz . 展开更多
关键词 ultrasonic welding ultrasonic cutting on line measurement electrical variables
下载PDF
Novel Optical Fiber Gas Sensor for On-line Measurement of Methane
5
作者 WANGShu-tao CHERen-sheng +1 位作者 LIUJin WANGYu-tian 《Semiconductor Photonics and Technology》 CAS 2004年第2期141-144,共4页
Based on analysis of near infrared spectral absorption of methane,absorption type optical fiber methane gas sensor with high sensitivity using DFB LD as a source is demonstrated. Light source modulation harmonic measu... Based on analysis of near infrared spectral absorption of methane,absorption type optical fiber methane gas sensor with high sensitivity using DFB LD as a source is demonstrated. Light source modulation harmonic measurement is presented in this paper. In order to eliminate the noise, the ratio of the fundamental and second-harmonic signals is used. The mathematical model of gas concentration harmonic measurement is built up.The detection result of methane concentration is also shown. Experiments have proved a sensitivity of 28×10-6. 展开更多
关键词 Gas sensor METHANE MODULATION Harmonic measurement
下载PDF
Development of an on-line measurement system for water-soluble organic matter in PM_(2.5) and its application in China 被引量:5
6
作者 Huiying Li Xiaofeng Huang +3 位作者 Liming Cao Yuhong Zhai Liwu Zeng Lingyan He 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2018年第7期33-40,共8页
Water-soluble organic matter(WSOM) represents a critical fraction of fine particles(PM2.5)in the air, but its changing behaviors and formation mechanisms are not well understood yet, partly due to the lack of fast... Water-soluble organic matter(WSOM) represents a critical fraction of fine particles(PM2.5)in the air, but its changing behaviors and formation mechanisms are not well understood yet, partly due to the lack of fast techniques for the ambient measurements. In this study,a novel system for the on-line measurement of water-soluble components in PM2.5, the particle-into-liquid sampler(PILS)–Nebulizer–aerosol chemical speciation monitor(ACSM), was developed by combining a PILS, a nebulizer, and an ACSM. High time resolution concentrations of WSOM, sulfate, nitrate, ammonium, and chloride, as well as mass spectra, can be obtained with satisfied quality control results. The system was firstly applied in China for field measurement of WSOM. The mass spectrum of WSOM was found to resemble that of oxygenated organic aerosol, and WSOM agreed well with secondary inorganic ions. All evidence collected in the field campaign demonstrated that WSOM could be a good surrogate of secondary organic aerosol(SOA). The PILS–Nebulizer–ACSM system can thus be a useful tool for intensive study of WSOM and SOA in PM2.5. 展开更多
关键词 PM2.5 Water-soluble organic matter Secondary organic matter on-line measurement Mass spectrum
原文传递
On-Line Measurement Method for Diameter and Roundness Error of Balls 被引量:4
7
作者 Yindi Cai Bo Xie +1 位作者 Siying Ling Kuang-Chao Fan 《Nanomanufacturing and Metrology》 2020年第3期218-227,共10页
This paper presents an on-line measurement method for the diameter and roundness error of balls.An easy-installation rotary scanning system,which integrates the principles of the diameter and the roundness measurement... This paper presents an on-line measurement method for the diameter and roundness error of balls.An easy-installation rotary scanning system,which integrates the principles of the diameter and the roundness measurements,is constructed.The rotary scanning system consists of a rotary stage,a linear stage,and two sensors with a什at probe.Two sensors are initially installed on the linear stage and contact each other.The outputs of two sensors are reset to zero at first.The ball is then mounted on the rotary stage and positioned between two flat probes.The variations of the diameter and the roundness error of the ball at each angular position can be directly recorded by two sensors when the ball is rotated by the rotary stage.Substituting the outputs of two sensors into the proposed mathematical models,the diameter and roundness error can be evaluated.The effects of the alignment error induced by the spindle error of the rotary stage and the titling error and the eccentric error of the ball on the measurement accuracy can be self-separated in the proposed on-line measurement method.A series of experiments are carried out to verify the effectiveness and the capability of the proposed on-line measurement method and the designed rotary scanning system.The designed system is easy to construct both in the laboratory environment and the factory field. 展开更多
关键词 on-line measurement DIAMETER Roundness error Alignment error
原文传递
Correlation between the rock mass properties and maximum horizontal stress:A case study of overcoring stress measurements
8
作者 Peng Li Meifeng Cai +2 位作者 Shengjun Miao Yuan Li Yu Wang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS 2025年第1期39-48,共10页
Understanding the mechanical properties of the lithologies is crucial to accurately determine the horizontal stress magnitude.To investigate the correlation between the rock mass properties and maximum horizontal stre... Understanding the mechanical properties of the lithologies is crucial to accurately determine the horizontal stress magnitude.To investigate the correlation between the rock mass properties and maximum horizontal stress,the three-dimensional(3D)stress tensors at 89 measuring points determined using an improved overcoring technique in nine mines in China were adopted,a newly defined characteristic parameter C_(ERP)was proposed as an indicator for evaluating the structural properties of rock masses,and a fuzzy relation matrix was established using the information distribution method.The results indicate that both the vertical stress and horizontal stress exhibit a good linear growth relationship with depth.There is no remarkable correlation between the elastic modulus,Poisson's ratio and depth,and the distribution of data points is scattered and messy.Moreover,there is no obvious relationship between the rock quality designation(RQD)and depth.The maximum horizontal stress σ_(H) is a function of rock properties,showing a certain linear relationship with the C_(ERP)at the same depth.In addition,the overall change trend of σ_(H) determined by the established fuzzy identification method is to increase with the increase of C_(ERP).The fuzzy identification method also demonstrates a relatively detailed local relationship betweenσ_H and C_(ERP),and the predicted curve rises in a fluctuating way,which is in accord well with the measured stress data. 展开更多
关键词 overcoring stress measurements elastic modulus Poisson's ratio rock quality designation maximum horizontal stress fuzzy identification
下载PDF
China’s High-Quality Technology Innovation:Scenario Narrative and Measurement System
9
作者 Chen Qiangyuan Zhao Haoyun +1 位作者 Lin Sitong Shen Yu 《China Economist》 2025年第1期2-28,共27页
The world today is undergoing disruptive,transformative shifts driven by a new wave of technological revolutions and industrial changes.In this context,a central question for China’s innovation-driven development str... The world today is undergoing disruptive,transformative shifts driven by a new wave of technological revolutions and industrial changes.In this context,a central question for China’s innovation-driven development strategy is how to effectively identify and measure high-quality technological innovations.Drawing on the stylized facts and scenario narrative of China’s technological landscape,this paper proposes a framework and measurement system for evaluating high-quality technological innovations.While China’s top-level design for technological innovation is guided by policy documents,the increasing number of enterprises applying for“high-tech enterprise”status has coincided with a decline in the quality of patent filings.In response,this paper first underscores the challenges and necessity of measuring the quality of technological innovations.Second,we introduce the high-quality technological innovation indicators and employ them to assess the quality of tech innovations at the firm level,utilizing an approach that combines analogical narrative,gene coding,text analysis,semantic logic,and a database of granted invention patents in China.Third,we examine the systematic and individual biases inherent in citation counts,a commonly used indicator,under specific contexts,and employ a granular instrumental variable approach to validate the effectiveness of the indicators.Finally,we develop a“family tree”of the indicators and explore their application scenarios through a combination of established and extended indicators.Our findings provide a theoretical foundation for evaluating China’s technological innovation quality,inform policy incentives,and offer insights for academia to apply high-quality technological innovation indicators in different contexts. 展开更多
关键词 Innovation quality technological innovation measurement system family tree
下载PDF
On-line measurement of temperature and water vapor in CH_4 /air premixed flame using near-infrared diode laser 被引量:4
10
作者 陶波 叶锡生 +2 位作者 胡志云 张立荣 刘晶儒 《Chinese Optics Letters》 SCIE EI CAS CSCD 2010年第11期1098-1101,共4页
We establish a single diode laser sensor system to obtain temperature and water concentration in CH4/air premixed flame.Line-of-sight properties are analyzed,but line-of-sight results are not path average values for t... We establish a single diode laser sensor system to obtain temperature and water concentration in CH4/air premixed flame.Line-of-sight properties are analyzed,but line-of-sight results are not path average values for temperature measurements.The measurements are performed on a flat burner based on scannedwavelength direct absorption spectroscopy using two adjacent water lines at 7153.75 and 7154.35 cm 1.Real-time results are acquired using a data acquisition card with a Labview data processing program.The standard uncertainties of the temperature and water concentration measurements are 2.3% and 5.1%,respectively. 展开更多
关键词 Data acquisition Data handling Infrared lasers Semiconductor lasers Temperature measurement Uncertainty analysis Water absorption Water piping systems Water supply Water vapor
原文传递
Integrated On-line Instrumentation System of Magnetic Properties Measurement
11
作者 D.G.Park, Y.Y.Song. H.Song and J.H.Hong (Korea Atomic Energy Research Institute, Yusong P.O.Box 105, Taejon, 305-600 Korea) C.G.Kim (Department of Physics, Sun Moon Univ., Asan-si, Chungnam, 336840 Korea) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第2期248-249,共2页
A portable microcomputer-controlled inspection system has been developed for detection of magnetic properties of soft magnetic materials. It incorporates custom designed software for control of the magnetic field duri... A portable microcomputer-controlled inspection system has been developed for detection of magnetic properties of soft magnetic materials. It incorporates custom designed software for control of the magnetic field during operation such as demagnetization, field sweeping, and for data logging and analysis. Results are recorded using a 12-bit analog to digital converter and are then stored on disk. The magnetic hysteresis loop and Barkhausen noise data can be converted into important magnetic parameters: coecivity, remanence, and hysteresis loss, Barkhausen amplitude, and Barkhausen noise energy. This system incorporated with the magnetostriction, and magnetoacoustic emission, is then related with the nondestructive detection of material degradation. 展开更多
关键词 line Integrated on-line Instrumentation System of Magnetic Properties measurement
下载PDF
On-line Temperature Rise Measurement of Submersible Motors
12
作者 王凤昌 刘宝廷 +1 位作者 宋黎明 姜思杰 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1995年第1期47-49,共3页
A new approach to the on-line temperature rise measurement of submersible pump's motors is presented. A new method of power supply and signed transmission for the measurement device in the pump well is also put fo... A new approach to the on-line temperature rise measurement of submersible pump's motors is presented. A new method of power supply and signed transmission for the measurement device in the pump well is also put forward here. The design and some experimental results are given. 展开更多
关键词 ss: SUBMERSIBLE MOTOR TEMPERATURE RISE on-line measurement
下载PDF
Experimental Study on an On-Line Measurement of High Temperature Circulating Ash Flux in a Circulating Fluidized Bed Boiler
13
作者 LuXiaofeng LiYourong 《Journal of Thermal Science》 SCIE EI CAS CSCD 2001年第2期188-192,共5页
A new Kind of measuring method that may be used to measure high temperature circulating solid particles flux in a circulating fluidized bed boiler is studied in this paper. The measuring method is founded on the princ... A new Kind of measuring method that may be used to measure high temperature circulating solid particles flux in a circulating fluidized bed boiler is studied in this paper. The measuring method is founded on the principle of thermal equilibrium. A series of cold tests and hot tests were carried to optimize the structure and collocation of water-cooling tubes and showed that the method had the advantage of simple, accurate, reliable and good applicability for on-line "usage in a circulating fluidized bed boiler. 展开更多
关键词 circulating fluidized bed boiler measurement ash.
原文传递
On-line non-intrusive particle size measurement of pulverised fuel through digital imaging 被引量:3
14
作者 Carter Robert M 《仪器仪表学报》 EI CAS CSCD 北大核心 2007年第11期1942-1946,共5页
This paper presents the basic principles of particle size measurement and latest industrial results recorded using an innovative optical instrumentation system designed to measure the size distribution of particles in... This paper presents the basic principles of particle size measurement and latest industrial results recorded using an innovative optical instrumentation system designed to measure the size distribution of particles in a pneumatic suspension.The system is non-intrusive and cost-effective.A low-cost CCD camera is used to capture images of the particulate flow field,which is illuminated by a low-cost pulsed laser sheet generator.The particle size distribution is then determined by processing the particle images through the use of novel processing algorithms.Experimental results obtained in the past on a small scale particle flow test rig have demonstrated that the system is capable of measuring the size distribution of pneumatically conveyed particles with an accuracy of a few percent.For the present paper results obtained when testing the system at a 4 MW industrial test facility are presented.Comparisons are made with both off-line reference data achieved through sieving and on-line laser diffraction data recorded using an intrusive,extractive,Malvern Instruments system.In general there is good agreement between results when considering the characteristics and limitations of the individual methodologies.The novel imaging system shows itself to be rugged,practical and useful under genuine industrial conditions. 展开更多
关键词 粒子 测量方法 数字成像 数码
下载PDF
Harmonics Measurement Analysis for a Stand Alone Photovoltaic System with Linear and Non-Linear Loads
15
作者 Hamisu Usman Ramatu Aliyu Abarshi Sani M. Lawal 《材料科学与工程(中英文A版)》 2014年第5期183-189,共7页
关键词 光伏发电系统 非线性负载 谐波失真 测量分析 独立光伏系统 电能质量分析仪 可再生能源 电子转换器
下载PDF
A portable instrument for measurement of atmospheric O_(x) and NO_(2) based on cavity ring-down spectroscopy 被引量:1
16
作者 Jinzhao Tong Renzhi Hu +5 位作者 Changjin Hu Haotian Cai Chuan Lin Jiawei Wang Liang Chen Pinhua Xie 《Atmospheric and Oceanic Science Letters》 CSCD 2024年第6期21-25,共5页
Atmospheric O_(x)(nitrogen dioxide(NO_(2))+ozone(O_(3)))can better reflect the local and regional change character-istics of oxidants compared to O_(3)alone,so obtaining O_(x)accurately and rapidly is the basis for ev... Atmospheric O_(x)(nitrogen dioxide(NO_(2))+ozone(O_(3)))can better reflect the local and regional change character-istics of oxidants compared to O_(3)alone,so obtaining O_(x)accurately and rapidly is the basis for evaluating the O_(3)production rate.Furthermore,O_(x)has proved to be a more representative indicator and can serve as a reflection of pollution prevention efficacy.A portable instrument for measuring atmospheric O_(x)and NO_(2)based on cavity ring-down spectroscopy(O_(x)/NO_(2)-CRDS)was developed in this work.The NO_(2)concentration is accurately mea-sured according to its absorption characteristic at 407.86 nm.Ambient O_(3)is converted into NO_(2)by chemical titration of high concentrations of nitrogen oxide(NO),and the O_(3)conversion efficiencies obtained are nearly 99%.The detection limit of the O_(x)/NO_(2)-CRDS system for O_(x)is 0.024 ppbv(0.1 s),and the overall uncertainty of the instrument is±6%.Moreover,the Kalman filtering technique was applied to improve the measurement accuracy of O_(x)/NO_(2)-CRDS.The system was applied in a comprehensive field observation campaign at Hefei Sci-ence Island from 26 to 30 September 2022,and the time concentration series and change characteristics of O_(x)and NO_(2)were obtained for five days.The measured O_(x)concentrations were compared with those of two com-mercial instruments,and the consistency was good(R^(2)=0.98),indicating that this system can be deployed to accurately and rapidly obtain the concentrations of atmospheric O_(x)and NO_(2).It will be a useful tool for assessing the atmospheric oxidation capacity and controlling O_(3)pollution. 展开更多
关键词 Cavity ring-down OXIDANT OZONE Portable measurement
下载PDF
A Study on Comprehensive Modeling for Errors in on-line Measuring System of Machining Center 被引量:1
17
作者 Liu Libing Zhang Qing(Tianjin University, Tianjin (300072) P. R. of ChinaZap Hongmei Yun Jintian)(Hebei University Of Technology, Tianjin (300130) P. R. of China) 《河北工业大学学报》 CAS 1997年第A01期14-22,共9页
Based on the theory of multi-body system (MBS), bine’s and huston’s methods are applied to an on-line measuring system of machining center in this paper. Through the study on modeling technique, the comprehensive mo... Based on the theory of multi-body system (MBS), bine’s and huston’s methods are applied to an on-line measuring system of machining center in this paper. Through the study on modeling technique, the comprehensive model for errors calculation in an on-line measuring System of machining center have been built for the first time. Using this model, the errors can be compensated by soft.ware and the measuring accuracy can be enhanced without any more inveSt. This model can be used in all kinds of machining center. 展开更多
关键词 MACHINING CENTER on-line measurING Multi-Body System (MBS) Model
下载PDF
STRONGLY CONVERGENT INERTIAL FORWARD-BACKWARD-FORWARD ALGORITHM WITHOUT ON-LINE RULE FOR VARIATIONAL INEQUALITIES
18
作者 姚永红 Abubakar ADAMU Yekini SHEHU 《Acta Mathematica Scientia》 SCIE CSCD 2024年第2期551-566,共16页
This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inerti... This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inertial parameters and the iterates,which have been assumed by several authors whenever a strongly convergent algorithm with an inertial extrapolation step is proposed for a variational inequality problem.Consequently,our proof arguments are different from what is obtainable in the relevant literature.Finally,we give numerical tests to confirm the theoretical analysis and show that our proposed algorithm is superior to related ones in the literature. 展开更多
关键词 forward-backward-forward algorithm inertial extrapolation variational inequality on-line rule
下载PDF
Influence of sampling on three-dimensional surface shape measurement
19
作者 QIAO Nao-sheng Shang Xue 《中国光学(中英文)》 EI CAS CSCD 北大核心 2024年第6期1512-1520,共9页
In order to accurately measure an object’s three-dimensional surface shape,the influence of sampling on it was studied.First,on the basis of deriving spectra expressions through the Fourier transform,the generation o... In order to accurately measure an object’s three-dimensional surface shape,the influence of sampling on it was studied.First,on the basis of deriving spectra expressions through the Fourier transform,the generation of CCD pixels was analyzed,and its expression was given.Then,based on the discrete expression of deformation fringes obtained after sampling,its Fourier spectrum expression was derived,resulting in an infinitely repeated"spectra island"in the frequency domain.Finally,on the basis of using a low-pass filter to remove high-order harmonic components and retaining only one fundamental frequency component,the inverse Fourier transform was used to reconstruct the signal strength.A method of reducing the sampling interval,i.e.,reducing the number of sampling points per fringe,was proposed to increase the ratio between the sampling frequency and the fundamental frequency of the grating.This was done to reconstruct the object’s surface shape more accurately under the condition of m>4.The basic principle was verified through simulation and experiment.In the simulation,the sampling intervals were 8 pixels,4 pixels,2 pixels,and 1 pixel,the maximum absolute error values obtained in the last three situations were 88.80%,38.38%,and 31.50%in the first situation,respectively,and the corresponding average absolute error values are 71.84%,43.27%,and 32.26%.It is demonstrated that the smaller the sampling interval,the better the recovery effect.Taking the same four sampling intervals in the experiment as in the simulation can also lead to the same conclusions.The simulated and experimental results show that reducing the sampling interval can improve the accuracy of object surface shape measurement and achieve better reconstruction results. 展开更多
关键词 three-dimensional surface shape measurement sampling interval spectra overlapping measurement accuracy
下载PDF
Bunch-length measurement at a bunch-by-bunch rate based on time–frequency-domain joint analysis techniques and its application
20
作者 Hong-Shuang Wang Xing Yang +2 位作者 Yong-Bin Leng Yi-Mei Zhou Ji-Gang Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期165-175,共11页
This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch si... This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch signal to obtain bunch-by-bunch and turn-by-turn longitudinal parameters,such as bunch length and synchronous phase.The bunch signal is obtained using a button electrode with a bandwidth of several gigahertz.The data acquisition device was a high-speed digital oscilloscope with a sampling rate of more than 10 GS/s,and the single-shot sampling data buffer covered thousands of turns.The bunch-length and synchronous phase information were extracted via offline calculations using Python scripts.The calibration coefficient of the system was determined using a commercial streak camera.Moreover,this technique was tested on two different storage rings and successfully captured various longitudinal transient processes during the harmonic cavity debugging process at the Shanghai Synchrotron Radiation Facility(SSRF),and longitudinal instabilities were observed during the single-bunch accumulation process at Hefei Light Source(HLS).For Gaussian-distribution bunches,the uncertainty of the bunch phase obtained using this technique was better than 0.2 ps,and the bunch-length uncertainty was better than 1 ps.The dynamic range exceeded 10 ms.This technology is a powerful and versatile beam diagnostic tool that can be conveniently deployed in high-energy electron storage rings. 展开更多
关键词 Bunch-by-bunch diagnostic Bunch-length measurement Synchronous phase measurement Joint time–frequency-domain analysis Longitudinal instability
下载PDF
上一页 1 2 250 下一页 到第