期刊文献+
共找到41篇文章
< 1 2 3 >
每页显示 20 50 100
A Yb optical clock with a lattice power enhancement cavity
1
作者 王春云 姚远 +3 位作者 师浩森 于洪浮 马龙生 蒋燕义 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期70-74,共5页
We construct a power enhancement cavity to form an optical lattice in an ytterbium optical clock.It is demonstrated that the intra-cavity lattice power can be increased by about 45 times,and the trap depth can be as l... We construct a power enhancement cavity to form an optical lattice in an ytterbium optical clock.It is demonstrated that the intra-cavity lattice power can be increased by about 45 times,and the trap depth can be as large as 1400Er when laser light with a power of only 0.6 W incident to the lattice cavity.Such high trap depths are the key to accurate evaluation of the lattice-induced light shift with an uncertainty down to~1×10-18.By probing the ytterbium atoms trapped in the power-enhanced optical lattice,we obtain a 4.3 Hz-linewidth Rabi spectrum,which is then used to feedback to the clock laser for the close loop operation of the optical lattice clock.We evaluate the density shift of the Yb optical lattice clock based on interleaving measurements,which is-0.46(62)mHz.This result is smaller compared to the density shift of our first Yb optical clock without lattice power enhancement cavity mainly due to a larger lattice diameter of 344μm. 展开更多
关键词 optical atomic clock optical lattice optical cavity Stark shift
下载PDF
A proposal for detecting weak electromagnetic waves around 2.6μm wavelength with Sr optical clock
2
作者 韩弱水 王伟 汪涛 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期452-457,共6页
Infrared signal detection is widely used in many fields.Due to the detection principle,however,the accuracy and range of detection are limited.Thanks to the ultra stability of the^(87)Sr optical lattice clock,external... Infrared signal detection is widely used in many fields.Due to the detection principle,however,the accuracy and range of detection are limited.Thanks to the ultra stability of the^(87)Sr optical lattice clock,external infrared electromagnetic wave disturbances can be responded to.Utilizing the ac Stark shift of the clock transition,we propose a new method to detect infrared signals.According to our calculations,the theoretical detection accuracy in the vicinity of its resonance band of 2.6μm can reach the order of 10-14W,while the minimum detectable signal of common detectors is on the order of 10^(-10)W. 展开更多
关键词 infrared signal detection ^(87)Sr optical lattice clock ac Stark shift ultra stability
下载PDF
Laboratory demonstration of geopotential measurement using transportable optical clocks 被引量:1
3
作者 刘道信 曹健 +6 位作者 袁金波 崔凯枫 袁易 张平 晁思嘉 舒华林 黄学人 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第1期272-277,共6页
We report an experimental demonstration of geopotential difference measurement using a pair of transportable ^(40)Ca^(+) optical clocks(TOC-729-1 and TOC-729-3)in the laboratory,each of them has an uncertainty of 1.3&... We report an experimental demonstration of geopotential difference measurement using a pair of transportable ^(40)Ca^(+) optical clocks(TOC-729-1 and TOC-729-3)in the laboratory,each of them has an uncertainty of 1.3×10^(−17) and an instability of 4.8×10^(−15)/√τ.Referenced to a stationary clock of TOC-729-1,the geopotential difference measurements are realized by moving TOC-729-3 to three different locations and the relevant altitude differences are measured with uncertainties at the level of 20 cm.After correcting the systematic shifts(including gravitational red shift),the two-clock frequency difference is measured to be–0.7(2.2)×10^(−17),considering both the statistic(1.0×10^(−17))and the systematic(1.9×10^(−17))uncertainties.The frequency difference between these two clocks is within their respective uncertainties,verifying the reliability of transportable ^(40)Ca^(+) optical clocks at the low level of 10^(−17). 展开更多
关键词 geopotential difference measurement transportable optical clock repeatability evaluation of clocks
下载PDF
A cryogenic radio-frequency ion trap for a 40Ca^(+) optical clock
4
作者 曾孟彦 黄垚 +6 位作者 张宝林 马子晓 郝艳梅 胡如明 张华青 管桦 高克林 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期232-239,共8页
A liquid-nitrogen cryogenic40Ca^(+)optical clock is presented that is designed to greatly reduce the blackbody radiation(BBR) shift. The ion trap, the electrodes and the in-vacuum BBR shield are installed under the li... A liquid-nitrogen cryogenic40Ca^(+)optical clock is presented that is designed to greatly reduce the blackbody radiation(BBR) shift. The ion trap, the electrodes and the in-vacuum BBR shield are installed under the liquid-nitrogen container,keeping the ions in a cryogenic environment at liquid-nitrogen temperature. Compared with the first design in our previous work, many improvements have been made to increase the performance. The liquid-nitrogen maintenance time has been increased by about three times by increasing the volume of the liquid-nitrogen container;the trap position recovery time after refilling the liquid-nitrogen container has been decreased more than three times by using a better fixation scheme in the liquid-nitrogen container;and the magnetic field noise felt by the ions has been decreased more than three times by a better design of the magnetic shielding system. These optimizations make the scheme for reducing the BBR shift uncertainty of liquid-nitrogen-cooled optical clocks more mature and stable, and develop a stable lock with a narrower linewidth spectrum,which would be very beneficial for further reducing the overall systematic uncertainty of optical clocks. 展开更多
关键词 cryogenics ion trapping 40Ca^(+)optical clock
下载PDF
A combined magnetic field stabilization system for improving the stability of 40Ca^(+) optical clock
5
作者 曾孟彦 马子晓 +6 位作者 胡如明 张宝林 郝艳梅 张华青 黄垚 管桦 高克林 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期226-231,共6页
Future applications of portable40Ca^(+)optical clocks require reliable magnetic field stabilization to improve frequency stability, which can be achieved by implementing an active and passive magnetic field noise supp... Future applications of portable40Ca^(+)optical clocks require reliable magnetic field stabilization to improve frequency stability, which can be achieved by implementing an active and passive magnetic field noise suppression system. On the one hand, we have optimized the magnetic shielding performance of the portable optical clock by reducing its apertures and optimizing its geometry;on the other hand, we have introduced an active magnetic field noise suppression system to further suppress the magnetic field noise experienced by the ions. These efforts reduced the ambient magnetic field noise by about 10000 times, significantly reduced the linewidth of the clock transition spectrum, improved the stability of the portable40Ca+optical clock, and created the conditions for using portable optical clocks in non-laboratory magnetic field environments. This active magnetic field suppression scheme has the advantages of simple installation and wide applicability. 展开更多
关键词 40Ca^(+)optical clock magnetic field compensation frequency stability
下载PDF
Study of optical clocks based on ultracold ^171Yb atoms 被引量:3
6
作者 Di Ai Hao Qiao +8 位作者 Shuang Zhang Li-Meng Luo Chang-Yue Sun Sheng Zhang Cheng-Quan Peng Qi-Chao Qi Tao-Yun Jin Min Zhou Xin-Ye Xu 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第9期79-83,共5页
The optical atomic clocks have the potential to transform global timekeeping,relying on the state-of-the-art accuracy and stability,and greatly improve the measurement precision for a wide range of scientific and tech... The optical atomic clocks have the potential to transform global timekeeping,relying on the state-of-the-art accuracy and stability,and greatly improve the measurement precision for a wide range of scientific and technological applications.Herein we report on the development of the optical clock based on 171Yb atoms confined in an optical lattice.A minimum width of 1.92-Hz Rabi spectra has been obtained with a new 578-nm clock interrogation laser.The in-loop fractional instability of the 171Yb clock reaches 9.1×10-18 after an averaging over a time of 2.0×104 s.By synchronous comparison between two clocks,we demonstrate that our 171Yb optical lattice clock achieves a fractional instability of 4.60×10-16/√τ. 展开更多
关键词 cold ytterbium atoms optical clocks ultra-stable clock lasers clock-transition spectra instability and uncertainty
下载PDF
Suppression of servo error uncertainty to 10^(-18)level using double integrator algorithm in ion optical clock 被引量:1
7
作者 Jin-Bo Yuan Jian Cao +5 位作者 Kai-Feng Cui Dao-Xin Liu Yi Yuan Si-Jia Chao Hua-Lin Shu Xue-Ren Huang 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第7期145-150,共6页
A universal locking model for single ion optical clocks was built based on a simple integrator and a double integrator.Different integrator algorithm parameters have been analyzed in both numerical simulations and exp... A universal locking model for single ion optical clocks was built based on a simple integrator and a double integrator.Different integrator algorithm parameters have been analyzed in both numerical simulations and experiments.The frequency variation measured by the comparison of two optical clocks coincides well with the simulation results for different second integrator parameters.According to the experimental results,the sensitivity of the servo error influenced by laser frequency drift with the addition of a double integrator was suppressed by a factor of 107.In a week-long comparison of optical clocks,the relative uncertainty of the servo error is determined to be 1.9×10^(-18),which is meaningful for the systematic uncertainty of the transportable single^(40)Ca^(+)ion optical clock entering the 10^(-18)level. 展开更多
关键词 optical clocks frequency uncertainty servo error servo algorithm
下载PDF
Direct Laser Cooling Al^+ Ion Optical Clocks 被引量:1
8
作者 张洁 邓科 +1 位作者 罗俊 陆泽晃 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第5期31-35,共5页
The Al^+ ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic... The Al^+ ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic-based spectroscopy technique. Its accuracy is limited by second-order Doppler shift, and its stability is limited by the number of ions that can be probed in quantum logic processing. We propose a direct laser cooling scheme of AI+ ion optical clocks where both the stability and accuracy of the clocks are greatly improved. In the proposed scheme, two Al^+ traps are utilized. The first trap is used to trap a large number of Al^+ ions to improve the stability of the clock laser, while the second trap is used to trap a single Al^+ ion to provide the ultimate accuracy. Both traps are cooled with a continuous wave 167nm laser. The expected clock laser stability can reach 9.0 × 10^-17/√τ. For the second trap, in addition to 167nm laser Doppler cooling, a second stage pulsed 234nm two-photon cooling laser is utilized to further improve the accuracy of the clock laser. The total systematic uncertainty can be reduced to about 1 × 10^-18. The proposed Al^+ ion optical clock has the potential to become the most accurate and stable optical clock. 展开更多
关键词 Direct Laser Cooling Al Ion optical clocks
下载PDF
All polarization-maintaining Er:fiber-based optical frequency comb for frequency comparison of optical clocks
9
作者 Pan Zhang Yan-Yan Zhang +7 位作者 Ming-Kun Li Bing-Jie Rao Lu-Lu Yan Fa-Xi Chen Xiao-Fei Zhang Qun-Feng Chen Hai-Feng Jiang Shou-Gang Zhang 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第5期364-369,共6页
We demonstrate an optical frequency comb(OFC)based on a turnkey mode-locked laser with a figure-9-shape structure and polarization-maintaining fibers,for the comparison of frequency among optical clocks with wavelengt... We demonstrate an optical frequency comb(OFC)based on a turnkey mode-locked laser with a figure-9-shape structure and polarization-maintaining fibers,for the comparison of frequency among optical clocks with wavelengths of 698 nm,729 nm,1068 nm,and 1156 nm.We adopt a multi-branch approach in order to produce high power OFC signals at these specific wavelengths,enabling the signal-to-noise ratio of the beatnotes between the OFC and the clock lasers to exceed30 d B at a resolution bandwidth of 300 k Hz.This approach makes the supercontinuum spectra much easier to be generated than a single branch OFC.However,more out-of-loop fibers degrade the long-term frequency instability due to thermal drift.To minimize the thermal drift effect,we set the fiber lengths of different branches to be similar,and we stabilize the temperature as well.The out-of-loop frequency instability of the OFC due to the incoherence of the multi-branch is about5.5×10^(19) for 4000 s,while the in-loop frequency instability of fceo and that of fbeat are 7.5×10^(18) for 1 s and 8.5×10^(18) for 1 s,respectively.The turnkey OFC meets the requirement for the comparison of frequency between the best optical clocks. 展开更多
关键词 optical frequency comb nonlinear amplifying loop mirror optical clock frequency instability
下载PDF
Correlation between the magic wavelengths and the polarization direction of the linearly polarized laser in the Ca^+ optical clock
10
作者 刘培亮 黄垚 +5 位作者 边武 邵虎 钱源 管桦 唐丽艳 高克林 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第3期474-477,共4页
The magic wavelengths for different Zeeman components are measured based on the ^40Ca^+ optical clock. The dynamic dipole polarizability of a non-zero angular moment level has correlation with the polarization direct... The magic wavelengths for different Zeeman components are measured based on the ^40Ca^+ optical clock. The dynamic dipole polarizability of a non-zero angular moment level has correlation with the polarization direction of the linearly polarized laser beam, and we show that the four hyperfine structure levels of 4S1/2,m=±1/2 and 3d5/2,m=±1/2 for ^40Ca^+ have the same dynamic dipole polarizability at the magic wavelength and a certain polarization direction. In addition, the existence of a specific direction of polarization may provide a new idea for improving the precision of magic wavelength measurement in experiment. 展开更多
关键词 optical clock dynamic dipole polarizability linearly polarized laser
下载PDF
Progress on the^40Ca^+ion optical clock
11
作者 Baolin Zhang x Yao Huang +4 位作者 Huaqing Zhang Yanmei Hao Mengyan Zeng Hua Guan Kelin Gao 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第7期69-76,共8页
Progress of the ^40Ca^+ion optical clock based on the 4^2S1/2-3d ^2D5/2 electric quadrupole transition is reported.By setting the drive frequency to the“magic”frequencyΩ0,the frequency uncertainty caused by the scal... Progress of the ^40Ca^+ion optical clock based on the 4^2S1/2-3d ^2D5/2 electric quadrupole transition is reported.By setting the drive frequency to the“magic”frequencyΩ0,the frequency uncertainty caused by the scalar Stark shift and second-order Doppler shift induced by micromotion is reduced to the 10^-19 level.By precisely measuring the differential static scalar polarizability∆α0,the uncertainty due to the blackbody radiation(BBR)shift(coefficient)is reduced to the 10^-19 level.With the help of a second-order integrating servo algorithm,the uncertainty due to the servo error is reduced to the 10^-18 level.The total fractional uncertainty of the ^40Ca^+ion optical clock is then improved to 2.2×10^-17,whereas this value is mainly restricted by the uncertainty of the BBR shift due to temperature fluctuations.The state preparation is introduced together with improvements in the pulse sequence,and furthermore,a better signal to noise ratio(SNR)and less dead time are achieved.The clock stability of a single clock is improved to 4.8×10^-15√τ(in seconds). 展开更多
关键词 ^40Ca^+ion optical clocks “magic”drive frequency frequency uncertainty frequency stability
下载PDF
Magic Wavelengths of the Optical Clock Transition at 1107 nm of Barium
12
作者 余庚华 许启明 +3 位作者 周超 段丞博 李隆 柴瑞鹏 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第3期34-38,共5页
Magic wavelengths for laser trapping of barium atoms in the optical clock transition at l107nm between the 6s2 1So state optical lattices are calculated with considering the and 6s5d 3D1 state. Theoretical calculation... Magic wavelengths for laser trapping of barium atoms in the optical clock transition at l107nm between the 6s2 1So state optical lattices are calculated with considering the and 6s5d 3D1 state. Theoretical calculation shows that there are several magic wavelengths with the linearly polarized trapping laser. The trap depths of the optical lattice and the slope of light shift difference with different magic wavelengths are also calculated, Some of these magic wavelengths are selected and recommended as potentially suitable magic wavelengths for the optical lattice trapping laser. 展开更多
关键词 BA 110 Magic Wavelengths of the optical clock Transition at 1107 nm of Barium
下载PDF
Theoretical calculations on Landé g-factors and quadratic Zeeman shift coefficients of nsnp ^(3)P_(0)^(o) clock states in Mg and Cd optical lattice clocks
13
作者 卢本全 常宏 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第1期278-285,共8页
The study of magnetic field effects on the clock transition of Mg and Cd optical lattice clocks is scarce.In this work,the hyperfine-induced Landég-factors and quadratic Zeeman shift coefficients of the nsnp ^(3)... The study of magnetic field effects on the clock transition of Mg and Cd optical lattice clocks is scarce.In this work,the hyperfine-induced Landég-factors and quadratic Zeeman shift coefficients of the nsnp ^(3)P_(0)^(o) clock states for ^(111,113)Cd and ^(25)Mg were calculated by using the multi-configuration Dirac–Hartree–Fock theory.To obtain accurate values of these parameters,the impact of electron correlations and furthermore the Breit interaction and quantum electrodynamical effects on the Zeeman and hyperfine interaction matrix elements,and energy separations were investigated in detail.We also estimated the contributions from perturbing states to the Landég-factors and quadratic Zeeman shift coefficients concerned so as to truncate the summation over the perturbing states without loss of accuracy.Our calculations provide important data for estimating the first-and second-order Zeeman shifts of the clock transition for the Cd and Mg optical lattice clocks. 展开更多
关键词 optical lattice clock hyperfine-induced Landég-factor quadratic Zeeman shift coefficient Mg and Cd
下载PDF
Strontium optical lattice clock at the National Time Service Center 被引量:11
14
作者 王叶兵 尹默娟 +5 位作者 任洁 徐琴芳 卢本全 韩建新 郭阳 常宏 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第2期204-209,共6页
We report the 87Sr optical lattice clock developed at the National Time Service Center. We achieved a closed-loop operation of the optical lattice clock based on 87Sr atoms. The linewidth of the spin-polarized clock p... We report the 87Sr optical lattice clock developed at the National Time Service Center. We achieved a closed-loop operation of the optical lattice clock based on 87Sr atoms. The linewidth of the spin-polarized clock peak is 3.9 Hz with a clock laser pulse length of 300 ms, which corresponds to a Fourier-limited linewidth of 3 Hz. The fitting of the in-loop error signal data shows that the instability is approximately 5 × 10 15τ-1/2, affected primarily by the white noise. The fractional frequency difference averages down to 5.7 × 10 ^-17 for an averaging time of 3000 s. 展开更多
关键词 optical clock optical lattice strontium atoms STABILITY
下载PDF
Realization of population inversion between 7S_(1/2) and 6P_(3/2) levels of cesium for four-level active optical clock 被引量:6
15
作者 WANG YanFei WANG DongYing +5 位作者 ZHANG TongGang HONG YeLong ZHANG ShengNan TAO ZhiMing XIE XiaoPeng CHEN JingBiao 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS 2013年第6期1107-1110,共4页
We demonstrate experimentally the population inversion between 7S1/2 and 6P3/2 levels of cesium in thermal cesium cell with a 455.5 nm pumping laser.We calculate the relative population probabilities at each level the... We demonstrate experimentally the population inversion between 7S1/2 and 6P3/2 levels of cesium in thermal cesium cell with a 455.5 nm pumping laser.We calculate the relative population probabilities at each level theoretically with the density matrix method.In a steady state,5.8% atoms are at 7S1/2 level and 2.9% at 6P3/2 level,which builds up the population inversion between the two levels.We obtain the fluorescence spectra produced in thermal cesium cell in our experiment.The measured relative intensity of each available fluorescence spectral line in the experiment agrees very well with the theoretical result.The demonstrated population inversion between 7S1/2 and 6P3/2 levels can be used to construct an active optical clock of four-level system with a wavelength of 1469.9 nm. 展开更多
关键词 active optical clock four-level system population inversion
原文传递
Observation of the ^1S0-^3P0 optical clock transition in cold ^199Hg atoms 被引量:2
16
作者 Xiaohu Fu Su Fang +5 位作者 Ruchen Zhao Ye Zhang Junchao Huang Jianfang Sun Zhen Xu Yuzhu Wang 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第6期6-10,共5页
We report on the observation of the highly forbidden ^1S0–^3P0 optical clock transition in laser-cooled ^199Hg atoms.More than 95% depletion of cold ^199Hg atoms is detected in the magneto-optical trap. Using the fre... We report on the observation of the highly forbidden ^1S0–^3P0 optical clock transition in laser-cooled ^199Hg atoms.More than 95% depletion of cold ^199Hg atoms is detected in the magneto-optical trap. Using the free-of-field detection method, the AC Stark shift from the cooling laser is removed from the in-field spectroscopy. At low-power clock laser pumping, the linewidth of the clock spectroscopy is approximately 450 k Hz(full width at half-maximum), which corresponds to a Doppler broadening at the atom temperature of 60 μK. We determine the -1S0–^13P0transition frequency to be 1,128,575,290.819(14) MHz by referencing with a hydrogen maser and measuring with a fiber optical frequency comb. Moreover, a weak Doppler-free signal is observed. 展开更多
关键词 STARK AC optical clock transition in cold Hg atoms Observation of the MOT AOM
原文传递
Synchronization of Fourier-Synthesized Optical Pulses to a Mode-Locked Optical Clock
17
作者 Masaharu Hyodo Kazi Sarwal Abedin +1 位作者 Noriaki Onodera Masayoshi Watanabe 《光学学报》 EI CAS CSCD 北大核心 2003年第S1期475-476,共2页
A Fourier-synthesized 40-GHz optical pulse train was successfully synchronized to an 8-GHz optical clock generated from a mode-locked fiber ring laser. The measured timing jitter of the synchronization was 0.43 ps.
关键词 of as be GHz FWM Synchronization of Fourier-Synthesized optical Pulses to a Mode-Locked optical clock Figure were SSB from
原文传递
Sympathetic electromagnetically induced transparency ground state cooling of a~(40)Ca^(+)–~(27)Al^(+)pair in an~(27)Al^(+)clock
18
作者 孙成龙 崔凯枫 +5 位作者 晁思嘉 魏远飞 袁金波 曹健 舒华林 黄学人 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第5期365-370,共6页
We report on electromagnetically induced transparency cooling of ^(40)Ca^(+)to sympathetically cool the threedimensional secular modes of motion in a ^(40)Ca^(+)–^(27)Al^(+)two-ion pair near the ground state.We obser... We report on electromagnetically induced transparency cooling of ^(40)Ca^(+)to sympathetically cool the threedimensional secular modes of motion in a ^(40)Ca^(+)–^(27)Al^(+)two-ion pair near the ground state.We observe simultaneous ground state cooling across all radial modes and axial modes of a ^(40)Ca^(+)–^(27)Al^(+)ion pair,occupying a broader cooling range in frequency space over 3 MHz.The cooling time is observed to be less than 1 ms.The mean phonon number and heating rates of all motional modes are measured.This study is not only an important step for reducing the secular motion time-dilation shift uncertainty and uptime ratio of ^(27)Al^(+)optical clock,but also essential for high-fidelity quantum simulations and quantum information processors using trapped ions. 展开更多
关键词 sympathetic electromagnetically induced transparency cooling trapped ions motional ground state ~(27)Al^(+)optical clock
下载PDF
A transportable optical lattice clock at the National Time Service Center 被引量:7
19
作者 De-Huan Kong Zhi-Hui Wang +4 位作者 Feng Guo Qiang Zhang Xiao-Tong Lu Ye-Bing Wang Hong Chang 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第7期92-98,共7页
We report a transportable one-dimensional optical lattice clock based on 87Sr at the National Time Service Center.The transportable apparatus consists of a compact vacuum system and compact optical subsystems.The vacu... We report a transportable one-dimensional optical lattice clock based on 87Sr at the National Time Service Center.The transportable apparatus consists of a compact vacuum system and compact optical subsystems.The vacuum system with a size of 90 cm×20 cm×42 cm and the beam distributors are assembled on a double-layer optical breadboard.The modularized optical subsystems are integrated on independent optical breadboards.By using a 230 ms clock laser pulse,spin-polarized spectroscopy with a linewidth of 4.8 Hz is obtained which is close to the 3.9 Hz Fourier-limit linewidth.The time interleaved self-comparison frequency instability is determined to be 6.3 × 10^-17 at an averaging time of 2000 s. 展开更多
关键词 optical lattice clock strontium atoms spin-polarized spectra INSTABILITY
下载PDF
First Evaluation and Frequency Measurement of the Strontium Optical Lattice Clock at NIM 被引量:14
20
作者 林弋戈 王强 +7 位作者 李烨 孟飞 林百科 臧二军 孙震 房芳 李天初 方占军 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第9期17-20,共4页
An optical lattice clock based on 87Sr is built at National Institute of Metrology (NIM) of China. The systematic frequency shifts of the clock are evaluated with a total uncertainty of 2.3×10-16. To measure it... An optical lattice clock based on 87Sr is built at National Institute of Metrology (NIM) of China. The systematic frequency shifts of the clock are evaluated with a total uncertainty of 2.3×10-16. To measure its absolute frequency with respect to NIM's cesium fountain clock NIM5, the frequency of a flywheel H-maser of NIM5 is transferred to the Sr laboratory through a 50-kin-long fiber. reference frequency of this H-maser, is used for the optical this Sr clock is measured to be 429228004229873.7(1.4)Hz. A fiber optical frequency comb, phase-locked to the frequency measurement. The absolute frequency of 展开更多
关键词 AOM First Evaluation and Frequency Measurement of the Strontium optical Lattice clock at NIM
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部