Due to the uneven seabed and heaving of soil during pumping,incomplete soil plugs may occur during the installation of bucket foundations,and the impacts on the bearing capacities of bucket foundations need to be eval...Due to the uneven seabed and heaving of soil during pumping,incomplete soil plugs may occur during the installation of bucket foundations,and the impacts on the bearing capacities of bucket foundations need to be evaluated.In this paper,the contact ratio(the ratio of the top diameter of the soil plug to the diameter of the bucket)and the soil plug ratio(the ratio of the soil heave height to the skirt height)are defined to describe the shape and size of the incomplete soil plug.Then,finite element models are established to investigate the bearing capacities of bucket foundations with incomplete soil plugs and the influences of the contact ratios,and the soil plug ratios on the bearing capacities are analyzed.The results show that the vertical bearing capacity of bucket foundations in homogeneous soil continuously improves with the increase of the contact ratio.However,in normally consolidated soil,the vertical bearing capacity barely changes when the contact ratio is smaller than 0.75,while the bearing capacity suddenly increases when the contact ratio increases to 1 due to the change of failure mode.The contact ratio hardly affects the horizontal bearing capacity of bucket foundations.Moreover,the moment bearing capacity improves with the increase of the contact ratio for small aspect ratios,but hardly varies with increasing contact ratio for aspect ratios larger than 0.5.Consequently,the reduction coefficient method is proposed based on this analysis to calculate the bearing capacities of bucket foundations considering the influence of incomplete soil plugs.The comparison results show that the proposed reduction coefficient method can be used to evaluate the influences of incomplete soil plug on the bearing capacities of bucket foundations.展开更多
Purging plug refractories in China typically contain around 3 mass% of super-fine chromium oxide in the matrix in order to improve the performance of the purging plugs, primarily, slag corrosion and wear resistance. A...Purging plug refractories in China typically contain around 3 mass% of super-fine chromium oxide in the matrix in order to improve the performance of the purging plugs, primarily, slag corrosion and wear resistance. Alternatives to chromium oxide containing refractories have gained interest due to health concerns related to the formation of soluble chromium compounds over long storage periods of refractory wastes. Super-ground reactive alumina can replace chromium oxide in purging plug refractories and this paper discussed the new reactive alumina E-SY 88 in comparison to chromium oxide in a typical purging plug castable. The mixing behaviour, wet castable properties, as well as cured, dried, and fired properties at different temperatures up to 1 600 ℃ were compared. In addition, the hot modulus of rupture, creep behaviour, thermal shock resistance and slag corrosion resistance were tested. The microstructure after slag corrosion was investigated by SEM. The results prove that E-SY 88 is an economically viable technical alternative to chromium oxide in purging plug refractories.展开更多
Damage reasons of purging plugs for refining ladle and research progress on thermal shock resistance of corundum- spinel purging plugs were summarized. Research achievements and application results of nonoxides bonded...Damage reasons of purging plugs for refining ladle and research progress on thermal shock resistance of corundum- spinel purging plugs were summarized. Research achievements and application results of nonoxides bonded corundum purging plugs for refining ladle were briefly reviewed. The further research and developing trend of purging plugs was proposed.展开更多
To clean out the smear layer on teeth surface, and protect the teeth medulla, the experiment applied the study observing the cleanup of six groups of surface smear layer of dental caries and the tubule plugs reserving...To clean out the smear layer on teeth surface, and protect the teeth medulla, the experiment applied the study observing the cleanup of six groups of surface smear layer of dental caries and the tubule plugs reserving effect after using of different cavity cleansers with the help of SEM. The result implied that both the acidic preparations and chelator could clean out the smear layer on teeth surface in some way, but the later one could also reserve partial tubule plugs, which reduce the stimulation to the teeth medulla. So the chelator is better cleansers in clinical use.展开更多
Corundum - spinel purging plugs were optimized through adjusting the formulation and the particle size composition of starting materials to prolong the service life of purging plugs for a 60 t refining ladle in a stee...Corundum - spinel purging plugs were optimized through adjusting the formulation and the particle size composition of starting materials to prolong the service life of purging plugs for a 60 t refining ladle in a steel plant. Th.e optimized formulatioa is 30 mass% tabular corundum (6 - 3 mm ) , 20 mass% tabular corundum (3-1 ram), 22 mass% tabular corundum (1 -0.5 ram) + sintered spinel, 28% tabular corundum fines (0. 045 mm) + fused spinel (0. 045 mm) + bimodal α-Al2O3 micropowder + Secar71 cement. The on-site results show that the plug can achieve an obviously long service life of 18 cycles, saving cost greatly.展开更多
In order to improve the properties of corundum based dispersive purging plugs,dispersive purging plug specimens were prepared using tabular corundum(1-0.15 and≤0.15 mm)as the aggregates,tabular corundum(≤0.044 mm)an...In order to improve the properties of corundum based dispersive purging plugs,dispersive purging plug specimens were prepared using tabular corundum(1-0.15 and≤0.15 mm)as the aggregates,tabular corundum(≤0.044 mm)andα-Al_(2)O_(3)micropowder(d_(50)=0.6μm)as the matrix,Secar 71 cement as the binder,introducing different amounts of nano-CaCO_(3),casting into shapes,and firing at different temperatures(1200 or 1600℃)for 4 h.The effects of the nano-CaCO_(3) extra-addition(0,0.5%,1.0%,1.5%and 2.0%,by mass)on the consistency of the castables as well as the properties and microstructure of the dispersive purging plug specimens were studied.The results show that:(1)with the fixed water addition,the consistency of the corundum castables decreases as the nano-CaCO_(3)addition increases;(2)with the increasing nano-CaCO_(3)addition,the bulk density of the specimens fired at different temperatures for 4 h decreases,the apparent porosity,the cold strength and the hot modulus of rupture all increase,the gas permeability does not change significantly;(3)the specimens fired at 1600℃ for 4 h have obviously better cold comprehensive performance than those fired at 1200℃for 4 h;(4)when the nano-CaCO_(3)addition is 1.5%,the comprehensive performance of the specimen is the optimal.展开更多
1 Scope This standard specifies the classification, technical requirements, test methods, inspection rules, marking, packing, transportation, storage and quality certificate of purging plugs and well blocks for refini...1 Scope This standard specifies the classification, technical requirements, test methods, inspection rules, marking, packing, transportation, storage and quality certificate of purging plugs and well blocks for refining ladle.展开更多
Major aortopulmonary collateral arteries (MAPCAs) are congenital vessels that arise from the aorta or its first-order branches and are distally connected to the pulmonary arterial vasculature, thereby providing pulmon...Major aortopulmonary collateral arteries (MAPCAs) are congenital vessels that arise from the aorta or its first-order branches and are distally connected to the pulmonary arterial vasculature, thereby providing pulmonary blood flow. MAPCAs are often associated with cyanotic congenital heart disease with decreased pulmonary blood flow. Isolated MAPCAs are rare in patients without congenital heart disease with structurally normal hearts. Sometimes, isolated congenital MAPCAs can occur without any lung disease. Isolated MAPCAs represent the occurrence of collaterals in the absence of underlying heart disease, which commonly presents as heart failure, recurrent respiratory tract infection, and pulmonary artery hypertension. We report a rare case of congestive heart failure in a 6-year-old patient with dual arterial supply to an otherwise normal right lung, with a normal bronchial tree, and a structurally normal heart. The patient was successfully managed by the closure of collaterals by Amplatzer vascular plugs II (AVPII) and Amplatzer Piccolo Occluders.展开更多
AIM: To evaluate the feasibility, clinical effect and predicting factors for favorable outcome of treatment with anal plugs in fecal incontinence and retrograde colonic irrigation (RCI) in patients with fecal incon...AIM: To evaluate the feasibility, clinical effect and predicting factors for favorable outcome of treatment with anal plugs in fecal incontinence and retrograde colonic irrigation (RCI) in patients with fecal incontinence or constipation.METHODS: Patients who received treatment with an anal plug or RCI between 1980 and 2005 were investigated with a questionnaire.RESULTS: Of the 201 patients (93 adults, 108 children), 101 (50%) responded. Adults: anal plugs (8), five stopped immediately, one stopped after 20 mo and two used it for 12-15 too. RCl (40, 28 fecal incontinence, 12 constipation), 63% are still using it (mean 8.5 years), 88% was satisfied. Younger adults (〈 40 years) were more satisfied with RCI (94 % vs 65%, P = 0.05). Children: anal plugs (7), 5 used it on demand for an average of 2.5 years with satisfactory results, one stopped immediately and one after 5 years. RCI (26 fecal incontinence, 22 constipation), 90% are still using it (mean time 6.8 years) and felt satisfied. Children tend to be more satisfied (P = 0.001). Besides age, no predictive factors for success were found. There was no difference in the outcome between patients with fecal incontinence or constipation.CONCLUSION: RCI is more often applied than anal plugs and is helpful in patients with fecal incontinence or constipation, especially for younger patients. Anal plugs can be used incidentally for fecal incontinence, especially in children.展开更多
The transport of liquid plugs in microchannels is very important for many applications such as in medical treatments in airways and in extraction of oil from porous rocks.A plug of wetting and non-wetting liquids driv...The transport of liquid plugs in microchannels is very important for many applications such as in medical treatments in airways and in extraction of oil from porous rocks.A plug of wetting and non-wetting liquids driven by a constant pressure difference through a T-shaped microchannel is studied numerically with lattice Boltzmann(LB) method.A two-phase flow LB model based on field mediators is built.Three typical flow patterns(blocking,rupture and splitting flow) of plug flow are obtained with different driving pressures.It is found that it becomes difficult for a plug with short initial plug length to leave the microchannel;the flow pattern of plug transport varies with the contact angle,especially from wetting to nonwetting;with the increase of interfacial tension,the front interface of plug moves faster;the front and rear interfaces of the plug with small viscosity ratio move faster in the microchannel than those of the plug with large viscosity ratio.The study is helpful to provide theoretical data for the design and scale-up of liquid-liquid reactors and separators.展开更多
A high-quality plug of the abandoned wellbore is considered an essential technical aspect of the oil and gas well abandonment technology system. This paper presents a method of active mechanical excitation to enhance ...A high-quality plug of the abandoned wellbore is considered an essential technical aspect of the oil and gas well abandonment technology system. This paper presents a method of active mechanical excitation to enhance the quality of wellbore plug barriers. An indoor simulation platform is developed, and the effects of different combinations of vibration frequency, amplitude and duration on the properties of the wellbore plug cement material are investigated. It is observed that the optimal combination of excitation parameters occurs at a vibration frequency of 15 Hz, a vibration time of 6 min, and a vibration amplitude of 3 mm. Compared with the condition without the vibration process, the cementing strength, compressive strength, and tensile strength of wellbore cement plug with the optimal mechanical vibration process could increase by 51%, 38% and 20%, respectively, while the porosity decreases by 5%. As determined by scanning electron microscopy of the set cement's microstructure, mechanical vibration effectively eliminates internal porosity and improves the set cement's density. The optimal excitation parameters obtained from the test can guide the design of the vibration plugging tool. The designed vibration plugging tool is simulated in the near field. The cement plug cementation quality tester tests the vibrating and non-vibrating samples, and the cementation ratio is calculated. The test results show that the average cementation ratio of vibrating samples is 0.89375, and that of non-vibrating samples is 0.70625, and the cementation quality is improved by 27%. It is concluded that it not only provides essential data for the design of mechanical vibration plug apparatus, on-site vibration plugs, and the development of operational specifications for vibration plugs, but also provides solid engineering guidance.展开更多
Gas hydrates and wax are the major flow assurance problems for the transportation of produced hydrocarbons through pipelines.However,in most research works both these two problems are studied separately.Although simul...Gas hydrates and wax are the major flow assurance problems for the transportation of produced hydrocarbons through pipelines.However,in most research works both these two problems are studied separately.Although simultaneous precipitation or deposition of these compounds in pipelines can lead to different mitigation/prevention strategies,the investi-gations in which both these problems are considered simultaneously appeared only recently.There is no information in the literature on the texture/composition and features of decomposition process of mixed wax/hydrate plugs.At the same time,this information could be useful to understand how to treat the problem of formation of these plugs.In this work,three wax/gas hydrate plugs were collected at quasi-static conditions from a water-in-oil emulsion to study their texture,composition and the features of decomposition process.Powder X-ray diffraction and IR(infrared spectroscopy)analyses showed that the plugs consisted of wax and gas hydrate.Thermovolumetric and DSC(Differential Scanning Calorimetry)experiments showed that the main part of gas hydrate in the plugs at the ambient pressure started to decompose at about 268 K.This temperature was higher than the equilibrium temperature of carbon dioxide hydrate at this pressure,indicating that the gas hydrate in the plugs could be effectively preserved at temperatures below the ice melting point(273.2 K).It was found through observation of the hydrate decomposition process in the plugs under the microscope that the gas in the samples released in small bubbles,while the hydrate particles were not visible at this magnification,indicating that the hydrate was indeed highly dispersed in the samples.A residual wax was jelly-like after decomposition of hydrate in all the cases.Rheological experiments showed that the plugs residues after decomposition of the hydrates had higher yield points and viscosities than the initial waxy crude oil origi-nally used for the experiments.展开更多
In breeding season and non-breeding season, the effects of three kinds of progesterone plugs on estrous control in ewes were studied. Meanwhile, the advantages and the disadvantages of the progesterone plugs were anal...In breeding season and non-breeding season, the effects of three kinds of progesterone plugs on estrous control in ewes were studied. Meanwhile, the advantages and the disadvantages of the progesterone plugs were analyzed. The results showed that there were no significant difference among three progesterone plugs on modulating the ewes' estrus and pregnancy, and affecting estrous rate and fecundation rate (P〉0.05). It was observed that the progesterone plug produced by Animal Husbandry Research Center of Heilongjiang Academy of Agricultural Sciences could modulate the ewes' estrus and pregnancy effectively, and the low cost and convenience in operation made it popularize in the reproducation of sheep widely.展开更多
AIM: To investigate donor site's area histological and immunohistochemical knee cartilage appearances after resurfacing iatrogenic defects with biosynthetic plugs orautografts. METHODS: Thirty New Zealand White ra...AIM: To investigate donor site's area histological and immunohistochemical knee cartilage appearances after resurfacing iatrogenic defects with biosynthetic plugs orautografts. METHODS: Thirty New Zealand White rabbits were used in this study. A full-thickness cylindrical defect of 4.5 mm(diameter) × 7 mm(depth) was created with a hand drill in the femoral groove of every animal. In Group A(n = 10) the defect of the donor site was re-paired with a biosynthetic osteochondral plug, in Group B(n = 10) with an osteochondral autograft, while in Group C(control group of 10) rabbits were left untreated. RESULTS: Twenty-four weeks postoperatively, smooth articular cartilage was found macroscopically in some trocleas' surfaces; in all others, an articular surface with discontinuities was observed. Twenty-eight out of 30 animals were found with predominantly viable chondrocytes leaving the remaining two-which were found only in the control group- with partially viable chondrocytes. However, histology revealed many statistical differences between the groups as far as the International Cartilage Repair Society(ICRS) categories are concerned. Immunofluoresence also revealed the presence of collagen Ⅱ in all specimens of Group B, whereas in Group A collagen Ⅱ was found in less specimens. In Group C collagen Ⅱwas not found. CONCLUSION: The matrix, cell distribution, subchondral bone and cartilage mineralization ICRS categories showed statistically differences between the three groups. Group A was second, while group B received the best scores; the control group got the worst ICRS scores in these categories. So, the donor site area, when repairing osteochondral lesions with autografting systems, is better amended with osteochondral autograft rather than bone graft substitute implant.展开更多
Purpose: To determine if there were differences in quality of life (QOL) within the first year following EVAR for patients undergoing internal iliac embolization depending on the type of device used. Methods: Patients...Purpose: To determine if there were differences in quality of life (QOL) within the first year following EVAR for patients undergoing internal iliac embolization depending on the type of device used. Methods: Patients who underwent endovascular AAA repair were identified using a Vascular surgery database at a tertiary care center from 2002-2008. The Radiology Information System and Image Viewer were then used to identify patients who underwent preprocedural embolization prior to endovascular aneurysm repair. Nine patients had embolization with nester coils, 9 had embolization with the amplatzer vascular plug, a type of nitinol based self expanding device. Another group of 8 patients who did not undergo preprocedural embolization was used as a comparator group. These patients were contacted via telephone and answered questions regarding QOL post procedure. The Australian Vascular QOL was the tool used to measure QOL. Differences in QOL were tabulated between the groups of patients. Results: Of the 9 patients who underwent embolization with amplatzer plug, the median QOL score was 60 (p value 0.575), the median QOL for the nester coil group was 52.5 and the comparator group was 58. Separate analysis was done dividing patients into two groups, with and without comorbidities without statistical significance. Conclusion: Patients who underwent preprocedural embolization using amplatzer plugs compared to coils had higher overall QOL scores although the difference was not significant.展开更多
Purpose:Evaluation of the patency and position of perforated lacrimal punctal plugs implanted for treating punctal stenosis together with quantitative assessment of the precorneal tear film using anterior segment opti...Purpose:Evaluation of the patency and position of perforated lacrimal punctal plugs implanted for treating punctal stenosis together with quantitative assessment of the precorneal tear film using anterior segment optical coherence tomography(AS-OCT).Methods:In a prospective study,the lower punctum of 54 eyes of 29 patients implanted with perforated punctal plugs were examined using AS-OCT during the early postoperative period.Preoperative tear meniscus height(TMH)and tear meniscus area(TMA)were evaluated.Postoperatively,the patency of the plug,its position,TMH and TMA were evaluated,and the results were correlated with postoperative epiphora.Munk scale was used for epiphora grading.Results:Using AS-OCT,48(88.9%)plugs were found in proper position while 6(11.1%)were rotated.The lumen of the plugs was completely patent in 47(87%)plugs,partially obstructed in 2(3.7%)plugs and completely occluded in 5(9.2%)plugs.There was a statistically significant postoperative decrease of TMH and TMA(P<0.001)and postoperative epiphora Munk score(P<0.001).Conclusion:AS-OCT is a valuable,reliable,and noninvasive investigative tool that can detect the proper positioning,patency,and contents of the implanted perforated lacrimal punctal plugs in addition to measurement of TMH and TMA.展开更多
Chronic eosinophilic pneumonia (CEP), a rare eosinophilic lung disease of unknown etiology,is characterized by peripheral blood eosinophilia, chest radiograph infiltrates, and prompt response to corticosteroid thera...Chronic eosinophilic pneumonia (CEP), a rare eosinophilic lung disease of unknown etiology,is characterized by peripheral blood eosinophilia, chest radiograph infiltrates, and prompt response to corticosteroid therapy. The first detailed description of CEP was described by Carrington et al in 1969. The usual symptoms are cough, dyspnea, fever, and weight loss. It is most often seen in middle aged woman and has a subacute onset. We report a case of CEP presenting with right lower lung infiltrates and mucus plugging that causing bronchus obstruction.展开更多
The use of biopsy plugs to sample fish muscle tissue for mercury analyses is a viable alternative to lethal sampling; however, the practice has yet to be widely implemented in routine monitoring due to concerns about ...The use of biopsy plugs to sample fish muscle tissue for mercury analyses is a viable alternative to lethal sampling; however, the practice has yet to be widely implemented in routine monitoring due to concerns about variability of mercury concentrations in fish muscle tissues. Here we examine distribution of mercury in fillets of four fish species(Walleye, Northern Pike, Smallmouth Bass and Lake Trout), suitability of left/right side of fillet for biopsy sampling, and appropriateness of re-using a biopsy punch. The results showed that average mercury concentrations in left and right fillets of fish are similar.Mercury concentrations in biopsy plug samples, taken from the anterior dorsal area of the fish fillet, were statistically equivalent to the mercury concentrations in homogenized fillets. There was no discernible cross contamination between samples when a biopsy punch was reused after washing in hot soapy water, and as such, biopsy punches can be recycled during sampling to reduce the sampling cost. If a tissue mass collected from a specific site on the fillet is insufficient, then we suggest sampling corresponding locations on the other fillet rather than sampling two adjacent sites on one fillet to obtain more tissue. The results presented here can improve the accuracy of fillet biopsy plug sampling,minimize fish mortality for mercury monitoring, and reduce labor and material costs in monitoring programs.展开更多
The integration of sustainable technologies in waste management systems has become imperative in addressing the escalating challenges of agricultural productivity and sustainability. Plugs are essential when starting ...The integration of sustainable technologies in waste management systems has become imperative in addressing the escalating challenges of agricultural productivity and sustainability. Plugs are essential when starting crop production in controlled environment agriculture (CEA) setups and greenhouses. Horticultural crops such as vegetables, fruiting, and ornamental plants that utilize plugs have demonstrated higher success rates, healthier plants, and higher total yields. The APS Laboratory for Sustainable Agriculture explored the innovative utilization of digestate from the Home Water-Energy-Food Systems (H-WEF). The H-WEF system converts household food waste into biogas, electricity, and nutrient-rich digestate. The digestate from the H-WEF system was used to produce agricultural plugs, presenting a novel approach to circular resource utilization. We carried out the growth of Rex Butterhead Lettuce Latuca sativa plugs with 1) control system (synthetic fertilizer) and seven different treatments, 2) 5% Digestate—95% RO Water (5D–95RO);3) 10% Digestate—90% RO Water (10D–90RO);4) 15% Digestate—85% RO Water (15D–85RO);5) 20% Digestate—80% RO Water (20D–80RO);6) 25% Digestate—75% RO Water (25D–75RO);7) 30% Digestate—70% RO Water (30D–70RO);8) 35% Digestate—65% RO Water (35D–65RO). The plugs were cultivated for 15 days in a controlled environment until two leaves had developed after the cotyledon. After 15 days, we collected data on wet weight (g), plug head area (cm2), total leaf area (cm2), total chlorophyll content (mg/cm2), and dry weight (g). In addition, we collected data on the Leaf Area Index (LAI, cm2/cm2) and Specific Leaf Area (SLA, cm2/g). The synthetic fertigation yielded a higher wet weight than the following treatments: 5D–95RO, 10D–90RO, and 35D–65RO. While the 30D–70RO treatment produced a larger plug head than all other treatments. The digestate-based fertilizers were comparable to the synthetic fertilizer at dilutions of 25D–75RO and 30D–70RO. This study underscores the viability of using digestate for plug production, providing crucial insights for growers navigating the challenges of sustainable agricultural practices.展开更多
As an independent sand control unit or a common protective shell of a high-quality screen,the punching screen is the outermost sand retaining unit of the sand control pipe which is used in geothermal well or oil and g...As an independent sand control unit or a common protective shell of a high-quality screen,the punching screen is the outermost sand retaining unit of the sand control pipe which is used in geothermal well or oil and gas well.However,most screens only consider the influence of the internal sand retaining medium parameters in the sand control performance design while ignoring the influence of the plugging of the punching screen on the overall sand retaining performance of the screen.To explore the clogging mechanism of the punching screen,this paper established the clogging mechanism calculation model of a single punching screen sand control unit by using the computational fluid mechanics-discrete element method(CFD-DEM)combined method.According to the combined motion of particles and fluids,the influence of the internal flow state on particle motion and accumulation was analyzed.The results showed that(1)the clogging process of the punching sand control unit is divided into three stages:initial clogging,aggravation of clogging and stability of clogging.In the initial stage of blockage,coarse particles form a loose bridge structure,and blockage often occurs preferentially at the streamline gathering place below chamfering inside the sand control unit.In the stage of blockage intensification,the particle mass develops into a relatively complete sand bridge,which develops from both ends of the opening to the center of the opening.In the stable plugging stage,the sand deposits show a“fan shape”and form a“V-shaped”gully inside the punching slot element.(2)Under a certain reservoir particle-size distribution,The slit length and opening height have a large influence on the permeability and blockage rate,while the slit width size has little influence on the permeability and blockage rate.The microscopic clogging mechanism and its law of the punching screen prevention unit are proposed in this study,which has some field guidance significance for the design of punching screen and sand prevention selection.展开更多
基金financially supported by the National Science Fund for Distinguished Young Scholars of China(Grant No.51825904)the Research on the Form,Design Method and Weathering Resistance of Key Components of Novel Floating Support Structures for Offshore Photovoltaics(Grant No.2022YFB4200701).
文摘Due to the uneven seabed and heaving of soil during pumping,incomplete soil plugs may occur during the installation of bucket foundations,and the impacts on the bearing capacities of bucket foundations need to be evaluated.In this paper,the contact ratio(the ratio of the top diameter of the soil plug to the diameter of the bucket)and the soil plug ratio(the ratio of the soil heave height to the skirt height)are defined to describe the shape and size of the incomplete soil plug.Then,finite element models are established to investigate the bearing capacities of bucket foundations with incomplete soil plugs and the influences of the contact ratios,and the soil plug ratios on the bearing capacities are analyzed.The results show that the vertical bearing capacity of bucket foundations in homogeneous soil continuously improves with the increase of the contact ratio.However,in normally consolidated soil,the vertical bearing capacity barely changes when the contact ratio is smaller than 0.75,while the bearing capacity suddenly increases when the contact ratio increases to 1 due to the change of failure mode.The contact ratio hardly affects the horizontal bearing capacity of bucket foundations.Moreover,the moment bearing capacity improves with the increase of the contact ratio for small aspect ratios,but hardly varies with increasing contact ratio for aspect ratios larger than 0.5.Consequently,the reduction coefficient method is proposed based on this analysis to calculate the bearing capacities of bucket foundations considering the influence of incomplete soil plugs.The comparison results show that the proposed reduction coefficient method can be used to evaluate the influences of incomplete soil plug on the bearing capacities of bucket foundations.
文摘Purging plug refractories in China typically contain around 3 mass% of super-fine chromium oxide in the matrix in order to improve the performance of the purging plugs, primarily, slag corrosion and wear resistance. Alternatives to chromium oxide containing refractories have gained interest due to health concerns related to the formation of soluble chromium compounds over long storage periods of refractory wastes. Super-ground reactive alumina can replace chromium oxide in purging plug refractories and this paper discussed the new reactive alumina E-SY 88 in comparison to chromium oxide in a typical purging plug castable. The mixing behaviour, wet castable properties, as well as cured, dried, and fired properties at different temperatures up to 1 600 ℃ were compared. In addition, the hot modulus of rupture, creep behaviour, thermal shock resistance and slag corrosion resistance were tested. The microstructure after slag corrosion was investigated by SEM. The results prove that E-SY 88 is an economically viable technical alternative to chromium oxide in purging plug refractories.
基金National Science Foundation of China ( No.51032007 and No.U1204505) for supporting this work
文摘Damage reasons of purging plugs for refining ladle and research progress on thermal shock resistance of corundum- spinel purging plugs were summarized. Research achievements and application results of nonoxides bonded corundum purging plugs for refining ladle were briefly reviewed. The further research and developing trend of purging plugs was proposed.
文摘To clean out the smear layer on teeth surface, and protect the teeth medulla, the experiment applied the study observing the cleanup of six groups of surface smear layer of dental caries and the tubule plugs reserving effect after using of different cavity cleansers with the help of SEM. The result implied that both the acidic preparations and chelator could clean out the smear layer on teeth surface in some way, but the later one could also reserve partial tubule plugs, which reduce the stimulation to the teeth medulla. So the chelator is better cleansers in clinical use.
文摘Corundum - spinel purging plugs were optimized through adjusting the formulation and the particle size composition of starting materials to prolong the service life of purging plugs for a 60 t refining ladle in a steel plant. Th.e optimized formulatioa is 30 mass% tabular corundum (6 - 3 mm ) , 20 mass% tabular corundum (3-1 ram), 22 mass% tabular corundum (1 -0.5 ram) + sintered spinel, 28% tabular corundum fines (0. 045 mm) + fused spinel (0. 045 mm) + bimodal α-Al2O3 micropowder + Secar71 cement. The on-site results show that the plug can achieve an obviously long service life of 18 cycles, saving cost greatly.
文摘In order to improve the properties of corundum based dispersive purging plugs,dispersive purging plug specimens were prepared using tabular corundum(1-0.15 and≤0.15 mm)as the aggregates,tabular corundum(≤0.044 mm)andα-Al_(2)O_(3)micropowder(d_(50)=0.6μm)as the matrix,Secar 71 cement as the binder,introducing different amounts of nano-CaCO_(3),casting into shapes,and firing at different temperatures(1200 or 1600℃)for 4 h.The effects of the nano-CaCO_(3) extra-addition(0,0.5%,1.0%,1.5%and 2.0%,by mass)on the consistency of the castables as well as the properties and microstructure of the dispersive purging plug specimens were studied.The results show that:(1)with the fixed water addition,the consistency of the corundum castables decreases as the nano-CaCO_(3)addition increases;(2)with the increasing nano-CaCO_(3)addition,the bulk density of the specimens fired at different temperatures for 4 h decreases,the apparent porosity,the cold strength and the hot modulus of rupture all increase,the gas permeability does not change significantly;(3)the specimens fired at 1600℃ for 4 h have obviously better cold comprehensive performance than those fired at 1200℃for 4 h;(4)when the nano-CaCO_(3)addition is 1.5%,the comprehensive performance of the specimen is the optimal.
文摘1 Scope This standard specifies the classification, technical requirements, test methods, inspection rules, marking, packing, transportation, storage and quality certificate of purging plugs and well blocks for refining ladle.
文摘Major aortopulmonary collateral arteries (MAPCAs) are congenital vessels that arise from the aorta or its first-order branches and are distally connected to the pulmonary arterial vasculature, thereby providing pulmonary blood flow. MAPCAs are often associated with cyanotic congenital heart disease with decreased pulmonary blood flow. Isolated MAPCAs are rare in patients without congenital heart disease with structurally normal hearts. Sometimes, isolated congenital MAPCAs can occur without any lung disease. Isolated MAPCAs represent the occurrence of collaterals in the absence of underlying heart disease, which commonly presents as heart failure, recurrent respiratory tract infection, and pulmonary artery hypertension. We report a rare case of congestive heart failure in a 6-year-old patient with dual arterial supply to an otherwise normal right lung, with a normal bronchial tree, and a structurally normal heart. The patient was successfully managed by the closure of collaterals by Amplatzer vascular plugs II (AVPII) and Amplatzer Piccolo Occluders.
文摘AIM: To evaluate the feasibility, clinical effect and predicting factors for favorable outcome of treatment with anal plugs in fecal incontinence and retrograde colonic irrigation (RCI) in patients with fecal incontinence or constipation.METHODS: Patients who received treatment with an anal plug or RCI between 1980 and 2005 were investigated with a questionnaire.RESULTS: Of the 201 patients (93 adults, 108 children), 101 (50%) responded. Adults: anal plugs (8), five stopped immediately, one stopped after 20 mo and two used it for 12-15 too. RCl (40, 28 fecal incontinence, 12 constipation), 63% are still using it (mean 8.5 years), 88% was satisfied. Younger adults (〈 40 years) were more satisfied with RCI (94 % vs 65%, P = 0.05). Children: anal plugs (7), 5 used it on demand for an average of 2.5 years with satisfactory results, one stopped immediately and one after 5 years. RCI (26 fecal incontinence, 22 constipation), 90% are still using it (mean time 6.8 years) and felt satisfied. Children tend to be more satisfied (P = 0.001). Besides age, no predictive factors for success were found. There was no difference in the outcome between patients with fecal incontinence or constipation.CONCLUSION: RCI is more often applied than anal plugs and is helpful in patients with fecal incontinence or constipation, especially for younger patients. Anal plugs can be used incidentally for fecal incontinence, especially in children.
基金Supported by the National Basic Research Program of China(2012CB224806)the National Natural Science Foundation of China(20990224,21276256)+1 种基金the National Natural Science Fund for Distinguished Young Scholars(21025627)the National High Technology Research and Development Program of China(2012AA03A606)
文摘The transport of liquid plugs in microchannels is very important for many applications such as in medical treatments in airways and in extraction of oil from porous rocks.A plug of wetting and non-wetting liquids driven by a constant pressure difference through a T-shaped microchannel is studied numerically with lattice Boltzmann(LB) method.A two-phase flow LB model based on field mediators is built.Three typical flow patterns(blocking,rupture and splitting flow) of plug flow are obtained with different driving pressures.It is found that it becomes difficult for a plug with short initial plug length to leave the microchannel;the flow pattern of plug transport varies with the contact angle,especially from wetting to nonwetting;with the increase of interfacial tension,the front interface of plug moves faster;the front and rear interfaces of the plug with small viscosity ratio move faster in the microchannel than those of the plug with large viscosity ratio.The study is helpful to provide theoretical data for the design and scale-up of liquid-liquid reactors and separators.
基金The authors wish to acknowledge the Open Foundation of Cooperative Innovation Center of Unconventional Oil and Gas,Yangtze University(Ministry of Education&Hubei Province),(Item No.UOGBX2022-04,UOG2022-26,UOGBX2022-05)the National Natural Science Foundation of China"New method and control mechanism of surface rotary steering drilling"(Item No.51974035,U1262108,U1762214)the key R&D program of Hubei Province"Development and application of multi-dimensional power integrated drilling tools for intelligent drilling"(Item No.2020BAB055)for the financial support to this paper。
文摘A high-quality plug of the abandoned wellbore is considered an essential technical aspect of the oil and gas well abandonment technology system. This paper presents a method of active mechanical excitation to enhance the quality of wellbore plug barriers. An indoor simulation platform is developed, and the effects of different combinations of vibration frequency, amplitude and duration on the properties of the wellbore plug cement material are investigated. It is observed that the optimal combination of excitation parameters occurs at a vibration frequency of 15 Hz, a vibration time of 6 min, and a vibration amplitude of 3 mm. Compared with the condition without the vibration process, the cementing strength, compressive strength, and tensile strength of wellbore cement plug with the optimal mechanical vibration process could increase by 51%, 38% and 20%, respectively, while the porosity decreases by 5%. As determined by scanning electron microscopy of the set cement's microstructure, mechanical vibration effectively eliminates internal porosity and improves the set cement's density. The optimal excitation parameters obtained from the test can guide the design of the vibration plugging tool. The designed vibration plugging tool is simulated in the near field. The cement plug cementation quality tester tests the vibrating and non-vibrating samples, and the cementation ratio is calculated. The test results show that the average cementation ratio of vibrating samples is 0.89375, and that of non-vibrating samples is 0.70625, and the cementation quality is improved by 27%. It is concluded that it not only provides essential data for the design of mechanical vibration plug apparatus, on-site vibration plugs, and the development of operational specifications for vibration plugs, but also provides solid engineering guidance.
文摘Gas hydrates and wax are the major flow assurance problems for the transportation of produced hydrocarbons through pipelines.However,in most research works both these two problems are studied separately.Although simultaneous precipitation or deposition of these compounds in pipelines can lead to different mitigation/prevention strategies,the investi-gations in which both these problems are considered simultaneously appeared only recently.There is no information in the literature on the texture/composition and features of decomposition process of mixed wax/hydrate plugs.At the same time,this information could be useful to understand how to treat the problem of formation of these plugs.In this work,three wax/gas hydrate plugs were collected at quasi-static conditions from a water-in-oil emulsion to study their texture,composition and the features of decomposition process.Powder X-ray diffraction and IR(infrared spectroscopy)analyses showed that the plugs consisted of wax and gas hydrate.Thermovolumetric and DSC(Differential Scanning Calorimetry)experiments showed that the main part of gas hydrate in the plugs at the ambient pressure started to decompose at about 268 K.This temperature was higher than the equilibrium temperature of carbon dioxide hydrate at this pressure,indicating that the gas hydrate in the plugs could be effectively preserved at temperatures below the ice melting point(273.2 K).It was found through observation of the hydrate decomposition process in the plugs under the microscope that the gas in the samples released in small bubbles,while the hydrate particles were not visible at this magnification,indicating that the hydrate was indeed highly dispersed in the samples.A residual wax was jelly-like after decomposition of hydrate in all the cases.Rheological experiments showed that the plugs residues after decomposition of the hydrates had higher yield points and viscosities than the initial waxy crude oil origi-nally used for the experiments.
基金Supported by Heilongjiang Institute of Agricultural Sciences Youth Funded Projects
文摘In breeding season and non-breeding season, the effects of three kinds of progesterone plugs on estrous control in ewes were studied. Meanwhile, the advantages and the disadvantages of the progesterone plugs were analyzed. The results showed that there were no significant difference among three progesterone plugs on modulating the ewes' estrus and pregnancy, and affecting estrous rate and fecundation rate (P〉0.05). It was observed that the progesterone plug produced by Animal Husbandry Research Center of Heilongjiang Academy of Agricultural Sciences could modulate the ewes' estrus and pregnancy effectively, and the low cost and convenience in operation made it popularize in the reproducation of sheep widely.
文摘AIM: To investigate donor site's area histological and immunohistochemical knee cartilage appearances after resurfacing iatrogenic defects with biosynthetic plugs orautografts. METHODS: Thirty New Zealand White rabbits were used in this study. A full-thickness cylindrical defect of 4.5 mm(diameter) × 7 mm(depth) was created with a hand drill in the femoral groove of every animal. In Group A(n = 10) the defect of the donor site was re-paired with a biosynthetic osteochondral plug, in Group B(n = 10) with an osteochondral autograft, while in Group C(control group of 10) rabbits were left untreated. RESULTS: Twenty-four weeks postoperatively, smooth articular cartilage was found macroscopically in some trocleas' surfaces; in all others, an articular surface with discontinuities was observed. Twenty-eight out of 30 animals were found with predominantly viable chondrocytes leaving the remaining two-which were found only in the control group- with partially viable chondrocytes. However, histology revealed many statistical differences between the groups as far as the International Cartilage Repair Society(ICRS) categories are concerned. Immunofluoresence also revealed the presence of collagen Ⅱ in all specimens of Group B, whereas in Group A collagen Ⅱ was found in less specimens. In Group C collagen Ⅱwas not found. CONCLUSION: The matrix, cell distribution, subchondral bone and cartilage mineralization ICRS categories showed statistically differences between the three groups. Group A was second, while group B received the best scores; the control group got the worst ICRS scores in these categories. So, the donor site area, when repairing osteochondral lesions with autografting systems, is better amended with osteochondral autograft rather than bone graft substitute implant.
文摘Purpose: To determine if there were differences in quality of life (QOL) within the first year following EVAR for patients undergoing internal iliac embolization depending on the type of device used. Methods: Patients who underwent endovascular AAA repair were identified using a Vascular surgery database at a tertiary care center from 2002-2008. The Radiology Information System and Image Viewer were then used to identify patients who underwent preprocedural embolization prior to endovascular aneurysm repair. Nine patients had embolization with nester coils, 9 had embolization with the amplatzer vascular plug, a type of nitinol based self expanding device. Another group of 8 patients who did not undergo preprocedural embolization was used as a comparator group. These patients were contacted via telephone and answered questions regarding QOL post procedure. The Australian Vascular QOL was the tool used to measure QOL. Differences in QOL were tabulated between the groups of patients. Results: Of the 9 patients who underwent embolization with amplatzer plug, the median QOL score was 60 (p value 0.575), the median QOL for the nester coil group was 52.5 and the comparator group was 58. Separate analysis was done dividing patients into two groups, with and without comorbidities without statistical significance. Conclusion: Patients who underwent preprocedural embolization using amplatzer plugs compared to coils had higher overall QOL scores although the difference was not significant.
文摘Purpose:Evaluation of the patency and position of perforated lacrimal punctal plugs implanted for treating punctal stenosis together with quantitative assessment of the precorneal tear film using anterior segment optical coherence tomography(AS-OCT).Methods:In a prospective study,the lower punctum of 54 eyes of 29 patients implanted with perforated punctal plugs were examined using AS-OCT during the early postoperative period.Preoperative tear meniscus height(TMH)and tear meniscus area(TMA)were evaluated.Postoperatively,the patency of the plug,its position,TMH and TMA were evaluated,and the results were correlated with postoperative epiphora.Munk scale was used for epiphora grading.Results:Using AS-OCT,48(88.9%)plugs were found in proper position while 6(11.1%)were rotated.The lumen of the plugs was completely patent in 47(87%)plugs,partially obstructed in 2(3.7%)plugs and completely occluded in 5(9.2%)plugs.There was a statistically significant postoperative decrease of TMH and TMA(P<0.001)and postoperative epiphora Munk score(P<0.001).Conclusion:AS-OCT is a valuable,reliable,and noninvasive investigative tool that can detect the proper positioning,patency,and contents of the implanted perforated lacrimal punctal plugs in addition to measurement of TMH and TMA.
文摘Chronic eosinophilic pneumonia (CEP), a rare eosinophilic lung disease of unknown etiology,is characterized by peripheral blood eosinophilia, chest radiograph infiltrates, and prompt response to corticosteroid therapy. The first detailed description of CEP was described by Carrington et al in 1969. The usual symptoms are cough, dyspnea, fever, and weight loss. It is most often seen in middle aged woman and has a subacute onset. We report a case of CEP presenting with right lower lung infiltrates and mucus plugging that causing bronchus obstruction.
文摘The use of biopsy plugs to sample fish muscle tissue for mercury analyses is a viable alternative to lethal sampling; however, the practice has yet to be widely implemented in routine monitoring due to concerns about variability of mercury concentrations in fish muscle tissues. Here we examine distribution of mercury in fillets of four fish species(Walleye, Northern Pike, Smallmouth Bass and Lake Trout), suitability of left/right side of fillet for biopsy sampling, and appropriateness of re-using a biopsy punch. The results showed that average mercury concentrations in left and right fillets of fish are similar.Mercury concentrations in biopsy plug samples, taken from the anterior dorsal area of the fish fillet, were statistically equivalent to the mercury concentrations in homogenized fillets. There was no discernible cross contamination between samples when a biopsy punch was reused after washing in hot soapy water, and as such, biopsy punches can be recycled during sampling to reduce the sampling cost. If a tissue mass collected from a specific site on the fillet is insufficient, then we suggest sampling corresponding locations on the other fillet rather than sampling two adjacent sites on one fillet to obtain more tissue. The results presented here can improve the accuracy of fillet biopsy plug sampling,minimize fish mortality for mercury monitoring, and reduce labor and material costs in monitoring programs.
文摘The integration of sustainable technologies in waste management systems has become imperative in addressing the escalating challenges of agricultural productivity and sustainability. Plugs are essential when starting crop production in controlled environment agriculture (CEA) setups and greenhouses. Horticultural crops such as vegetables, fruiting, and ornamental plants that utilize plugs have demonstrated higher success rates, healthier plants, and higher total yields. The APS Laboratory for Sustainable Agriculture explored the innovative utilization of digestate from the Home Water-Energy-Food Systems (H-WEF). The H-WEF system converts household food waste into biogas, electricity, and nutrient-rich digestate. The digestate from the H-WEF system was used to produce agricultural plugs, presenting a novel approach to circular resource utilization. We carried out the growth of Rex Butterhead Lettuce Latuca sativa plugs with 1) control system (synthetic fertilizer) and seven different treatments, 2) 5% Digestate—95% RO Water (5D–95RO);3) 10% Digestate—90% RO Water (10D–90RO);4) 15% Digestate—85% RO Water (15D–85RO);5) 20% Digestate—80% RO Water (20D–80RO);6) 25% Digestate—75% RO Water (25D–75RO);7) 30% Digestate—70% RO Water (30D–70RO);8) 35% Digestate—65% RO Water (35D–65RO). The plugs were cultivated for 15 days in a controlled environment until two leaves had developed after the cotyledon. After 15 days, we collected data on wet weight (g), plug head area (cm2), total leaf area (cm2), total chlorophyll content (mg/cm2), and dry weight (g). In addition, we collected data on the Leaf Area Index (LAI, cm2/cm2) and Specific Leaf Area (SLA, cm2/g). The synthetic fertigation yielded a higher wet weight than the following treatments: 5D–95RO, 10D–90RO, and 35D–65RO. While the 30D–70RO treatment produced a larger plug head than all other treatments. The digestate-based fertilizers were comparable to the synthetic fertilizer at dilutions of 25D–75RO and 30D–70RO. This study underscores the viability of using digestate for plug production, providing crucial insights for growers navigating the challenges of sustainable agricultural practices.
文摘As an independent sand control unit or a common protective shell of a high-quality screen,the punching screen is the outermost sand retaining unit of the sand control pipe which is used in geothermal well or oil and gas well.However,most screens only consider the influence of the internal sand retaining medium parameters in the sand control performance design while ignoring the influence of the plugging of the punching screen on the overall sand retaining performance of the screen.To explore the clogging mechanism of the punching screen,this paper established the clogging mechanism calculation model of a single punching screen sand control unit by using the computational fluid mechanics-discrete element method(CFD-DEM)combined method.According to the combined motion of particles and fluids,the influence of the internal flow state on particle motion and accumulation was analyzed.The results showed that(1)the clogging process of the punching sand control unit is divided into three stages:initial clogging,aggravation of clogging and stability of clogging.In the initial stage of blockage,coarse particles form a loose bridge structure,and blockage often occurs preferentially at the streamline gathering place below chamfering inside the sand control unit.In the stage of blockage intensification,the particle mass develops into a relatively complete sand bridge,which develops from both ends of the opening to the center of the opening.In the stable plugging stage,the sand deposits show a“fan shape”and form a“V-shaped”gully inside the punching slot element.(2)Under a certain reservoir particle-size distribution,The slit length and opening height have a large influence on the permeability and blockage rate,while the slit width size has little influence on the permeability and blockage rate.The microscopic clogging mechanism and its law of the punching screen prevention unit are proposed in this study,which has some field guidance significance for the design of punching screen and sand prevention selection.