期刊文献+
共找到123篇文章
< 1 2 7 >
每页显示 20 50 100
Seeing beneath the surface:Harnessing point-of-care ultrasound for internal jugular vein evaluation 被引量:2
1
作者 Vichayut Chayapinun Abhilash Koratala Taweevat Assavapokee 《World Journal of Cardiology》 2024年第2期73-79,共7页
Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to... Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to conditions such as liver disease or abdominal surgery.While many clinicians are familiar with visually assessing jugular venous pressure through the internal jugular vein,this method lacks sensitivity.The utilization of POCUS significantly enhances the visualization of the vein,leading to a more accurate identification.It has been demonstrated that combining IJV POCUS with physical examination enhances the specificity of RAP estimation.This review aims to provide a comprehensive summary of the various sonographic techniques available for estimating RAP from the internal jugular vein,drawing upon existing data. 展开更多
关键词 point-of-care ultrasound Bedside ultrasound Internal jugular vein Right atrial pressure Central venous pressure
下载PDF
Evaluation of hand infections in the emergency department using point-of-care ultrasound 被引量:1
2
作者 David Ahmad Haidar David Mintz +2 位作者 Brandon M Wubben Omar Rizvi Srikar Adhikari 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第4期283-288,共6页
BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient mana... BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient management.METHODS:We conducted a retrospective review of patients who presented to two urban academic EDs with clinical presentations concerning for skin and soft tissue infections(SSTI)of the hand between December 2015 and December 2021.Two trained POCUS fellowship physicians reviewed an ED POCUS database for POCUS examinations of the hand.We then reviewed patients’electronic health records(EHR)for demographic characteristics,history,physical examination findings,ED course,additional imaging studies,consultations,impact of POCUS on patient care and final disposition.RESULTS:We included a total of 50 cases(28 male,22 female)in the final analysis.The most common presenting symptoms and exam findings were pain(100%),swelling(90%),and erythema(74%).The most common sonographic findings were edema(76%),soft tissue swelling(78%),and fluid surrounding the tendon(57%).POCUS was used in medical decision making 68%of the time(n=34),with the use of POCUS leading to changes in management 38%of the time(n=19).POCUS use led to early antibiotic use(11/19),early consultation(10/19),and led to the performance of a required procedure(8/19).The POCUS diagnosis was consistent with the discharge diagnosis of flexor tenosynovitis 8/12 times,abscess 12/16 times,and cellulitis 14/20 times.CONCLUSION:POCUS is beneficial for evaluating of hand infections that present to the ED and can be used as an important part of medical decision making to expedite patient care. 展开更多
关键词 ULTRASOUND point-of-care ultrasound CELLULITIS ABSCESS Flexor tenosynovitis
下载PDF
Electrochemical biosensors for point-of-care testing 被引量:1
3
作者 Jinsol Kim Juho Jeong Seung Hwan Ko 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第4期548-565,共18页
Point-of-care testing(POCT)is the practice of diagnosing and monitoring diseases where the patient is located,as opposed to traditional treatment conducted solely in a medical laboratory or other clinical setting.POCT... Point-of-care testing(POCT)is the practice of diagnosing and monitoring diseases where the patient is located,as opposed to traditional treatment conducted solely in a medical laboratory or other clinical setting.POCT has been less common in the recent past due to a lack of portable medical devices capable of facilitating effective medical testing.However,recent growth has occurred in this field due to advances in diagnostic technologies,device miniaturization,and progress in wearable electronics.Among these developments,electrochemical sensors have attracted interest in the POCT field due to their high sensitivity,compact size,and affordability.They are used in various applications,from disease diagnosis to health status monitoring.In this paper we explore recent advancements in electrochemical sensors,the methods of fabricating them,and the various types of sensing mechanisms that can be used.Furthermore,we delve into methods for immobilizing specific biorecognition elements,including enzymes,antibodies,and aptamers,onto electrode surfaces and how these sensors are used in real-world POCT settings. 展开更多
关键词 point-of-care testing(POCT) Electrochemical sensor ENZYME ANTIBODY Health care
下载PDF
CeFe nanofibrous carbon nanozyme integrated with smartphone for the point-of-care testing of norfloxacin in water
4
作者 Yue Liu Taimei Cai +2 位作者 Sen Chen Tao Wen Hailong Peng 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2024年第10期1505-1513,共9页
The overuse of antibiotics has led to the severe contamination of water bodies,posing a considerable hazard to human health.Therefore,the development of an accurate and rapid point-of-care testing(POCT)platform for th... The overuse of antibiotics has led to the severe contamination of water bodies,posing a considerable hazard to human health.Therefore,the development of an accurate and rapid point-of-care testing(POCT)platform for the quantitative detection of antibiotics is necessary.In this study,Cerium oxide(CeO_(2))and Ferrosoferric oxide(Fe_(3)O_(4))nanoparticles were simultaneously encapsulated into N-doped nanofibrous carbon microspheres to form of a novel nanozyme(CeFe-NCMzyme)with a porous structure,high surface area,and N-doped carbon material properties,leading to a considerable enhancement of the peroxidase(POD)-like activity compared with that of the CeO_(2)or Fe3O4 nanoparticles alone.The POD-like activity of CeFe-NCMzyme can be quenched using L-Cysteine(Cys)and subsequently restored by the addition of a quinolone antibiotic(norfloxacin,NOR).Therefore,CeFe-NCMzyme was used as a colorimetric sensor to detect NOR via an“On-Off”model of POD-like activity.The sensor possessed a wide linear range of 0.05–20.0μM(R^(2)=0.9910)with a detection limit of 35.70 nM.Furthermore,a smartphone-assisted POCT platform with CeFe-NCMzyme was fabricated for quantitative detection of NOR based on RGB analysis.With the use of the POCT platform,a linear range of 0.1–20.0μM and a detection limit of 54.10 nM were obtained.The spiked recoveries in the water samples were ranged from 97.73%to 102.01%,and the sensor exhibited good accuracy and acceptable reliability.This study provides a portable POCT platform for the on-site and quantitative monitoring of quinolone antibiotics in real samples,particularly in resource-constrained settings. 展开更多
关键词 CeO_(2)nanoparticles Peroxidase-like activity Nanofibrous carbon microspheres point-of-care testing NORFLOXACIN
下载PDF
Point-of-care ultrasonography in cirrhosis-related acute kidney injury:How I do it
5
作者 Abhilash Koratala 《World Journal of Critical Care Medicine》 2024年第2期137-149,共13页
Discerning the etiology of acute kidney injury(AKI)in cirrhotic patients remains a formidable challenge due to diverse and overlapping causes.The conventional approach of empiric albumin administration for suspected v... Discerning the etiology of acute kidney injury(AKI)in cirrhotic patients remains a formidable challenge due to diverse and overlapping causes.The conventional approach of empiric albumin administration for suspected volume depletion may inadvertently lead to fluid overload.In the recent past,point-of-care ultrasonography(POCUS)has emerged as a valuable adjunct to clinical assessment,offering advantages in terms of diagnostic accuracy,rapidity,cost-effectiveness,and patient satisfaction.This review provides insights into the strategic use of POCUS in evaluating cirrhotic patients with AKI.The review distinguishes basic and advanced POCUS,emphasizing a 5-point basic POCUS protocol for efficient assessment.This protocol includes evaluations of the kidneys and urinary bladder for obstructive nephropathy,lung ultrasound for detecting extravascular lung water,inferior vena cava(IVC)ultrasound for estimating right atrial pressure,internal jugular vein ultrasound as an alternative to IVC assessment,and focused cardiac ultrasound for assessing left ventricular(LV)systolic function and identifying potential causes of a plethoric IVC.Advanced POCUS delves into additional Doppler parameters,including stroke volume and cardiac output,LV filling pressures and venous congestion assessment to diagnose or prevent iatrogenic fluid overload.POCUS,when employed judiciously,enhances the diagnostic precision in evaluating AKI in cirrhotic patients,guiding appropriate therapeutic interventions,and minimizing the risk of fluid-related complications. 展开更多
关键词 point-of-care ULTRASOUND HEMODYNAMIC Right atrial pressure Hepatorenal NEPHROLOGY
下载PDF
Point-of-care ultrasonography spotlight:Could venous excess ultrasound serve as a shared language for internists and intensivists?
6
作者 Anosh Aslam Khan Hasham Saeed +3 位作者 Ibtehaj Ul Haque Ayman Iqbal Doantrang Du Abhilash Koratala 《World Journal of Critical Care Medicine》 2024年第2期126-136,共11页
Point-of-care ultrasonography(POCUS),particularly venous excess ultrasound(VExUS)is emerging as a valuable bedside tool to gain real-time hemodynamic insights.This modality,derived from hepatic vein,portal vein,and in... Point-of-care ultrasonography(POCUS),particularly venous excess ultrasound(VExUS)is emerging as a valuable bedside tool to gain real-time hemodynamic insights.This modality,derived from hepatic vein,portal vein,and intrarenal vessel Doppler patterns,offers a scoring system for dynamic venous congestion assessment.Such an assessment can be crucial in effective management of patients with heart failure exacerbation.It facilitates diagnosis,quantification of congestion,prognostication,and monitoring the efficacy of decongestive therapy.As such,it can effectively help to manage cardiorenal syndromes in various clinical settings.Extended or eVExUS explores additional veins,potentially broadening its applications.While VExUS demonstrates promising outcomes,challenges persist,particularly in cases involving renal and liver parenchymal disease,arrhythmias,and situations of pressure and volume overload overlap.Proficiency in utilizing spectral Doppler is pivotal for clinicians to effectively employ this tool.Hence,the integration of POCUS,especially advanced applications like VExUS,into routine clinical practice necessitates enhanced training across medical specialties. 展开更多
关键词 point-of-care ultrasonography ULTRASOUND Venous excess ultrasound Doppler Congestion Heart failure
下载PDF
Point-of-care ultrasound in nephrology:A private practice viewpoint
7
作者 Rajiv Sinanan Afsheen Moshtaghi Abhilash Koratala 《World Journal of Methodology》 2024年第4期30-42,共13页
Point-of-care ultrasound(POCUS)is a limited ultrasound examination performed by the clinician at the bedside,emerging as a complement to physical examination across various medical specialties.In the field of nephrolo... Point-of-care ultrasound(POCUS)is a limited ultrasound examination performed by the clinician at the bedside,emerging as a complement to physical examination across various medical specialties.In the field of nephrology,its integration has been gradual,primarily limited to guiding procedures like temporary dialysis catheter placement or,in some cases,diagnostic kidney ultrasounds.In reality,the assessment of hemodynamic status at the bedside holds immense value for nephrologists,yet there exists limited awareness among practitioners regarding its implementation.While there is a growing trend towards incorporating multiorgan POCUS training in fellowship programs,private practice nephrologists remain relatively uninformed.This discussion explores the untapped potential of POCUS as a valuable diagnostic tool in everyday nephrology practice,demonstrating its effectiveness in diverse clinical settings,ranging from medical wards to outpatient dialysis units.Additionally,we delve into the challenges hindering its widespread adoption and consider the future trajectory of this innovative approach. 展开更多
关键词 point-of-care ultrasound Bedside ultrasound NEPHROLOGY HEMODYNAMICS CIRRHOSIS Acute kidney injury
下载PDF
Sound waves and solutions:Point-of-care ultrasonography for acute kidney injury in cirrhosis
8
作者 David Aguirre-Villarreal Mario Andrés de Jesús Leal-Villarreal +2 位作者 Ignacio García-Juárez Eduardo R Argaiz Abhilash Koratala 《World Journal of Critical Care Medicine》 2024年第2期83-92,共10页
This article delves into the intricate challenges of acute kidney injury(AKI)in cirrhosis,a condition fraught with high morbidity and mortality.The complexities arise from distinguishing between various causes of AKI,... This article delves into the intricate challenges of acute kidney injury(AKI)in cirrhosis,a condition fraught with high morbidity and mortality.The complexities arise from distinguishing between various causes of AKI,particularly hemodynamic AKI,in cirrhotic patients,who experience hemodynamic changes due to portal hypertension.The term"hepatocardiorenal syndrome"is introduced to encapsulate the intricate interplay among the liver,heart,and kidneys.The narrative emphasizes the often-overlooked aspect of cardiac function in AKI assessments in cirrhosis,unveiling the prevalence of cirrhotic cardiomyopathy marked by impaired diastolic function.The conventional empiric approach involving volume expansion and vasopressors for hepatorenal syndrome is critically analyzed,highlighting potential risks and variable patient responses.We advocate for a nuanced algorithm for AKI evaluation in cirrhosis,prominently featuring point-of-care ultrasonography(POCUS).POCUS applications encompass assessing fluid tolerance,detecting venous congestion,and evaluating cardiac function. 展开更多
关键词 point-of-care ultrasonography Bedside ultrasound CIRRHOSIS CONGESTION Acute kidney injury Congestive nephropathy
下载PDF
基于point-of-care理念的手卫生设施设置现状调查 被引量:14
9
作者 胡美华 姚希 +8 位作者 赵艳春 贾建侠 赵秀莉 贾会学 钱晶京 张然 路简羽 张冰丽 李六亿 《中国感染控制杂志》 CAS CSCD 北大核心 2021年第8期716-719,共4页
目的基于point-of-care(POC)理念调查某三级甲等综合性教学医院手卫生设施的设置现状。方法采用横断面方法调查该院各诊疗区域主要供医务人员使用的手卫生设施种类、数量、位置、设施完备程度,以及速干手消毒剂的消耗量。结果调查102个... 目的基于point-of-care(POC)理念调查某三级甲等综合性教学医院手卫生设施的设置现状。方法采用横断面方法调查该院各诊疗区域主要供医务人员使用的手卫生设施种类、数量、位置、设施完备程度,以及速干手消毒剂的消耗量。结果调查102个区域,1165间诊疗用房,手卫生设施配置率为96.48%,洗手池完备率为91.37%%,不同区域完备率比较,差异有统计学意义(P<0.01)。80.53%的速干手消毒剂设置符合POC理念,59.51%的普通病区病室速干手消毒剂设置符合POC理念,速干手消毒剂设置符合POC理念比例高的科室手消毒剂消耗量相对较高。结论手卫生设施的设置和改进应强化POC理念,以提高手卫生依从性和预防医院感染的发生。 展开更多
关键词 手卫生 设施 point-of-care(POC) 医院感染
下载PDF
Point-of-care ultrasound in a pandemic:Practical guidance in COVID-19 units
10
作者 Himanshu Deshwal Deepak Pradhan Vikramjit Mukherjee 《World Journal of Critical Care Medicine》 2021年第5期204-219,共16页
The coronavirus disease 2019(COVID-19)pandemic has stretched our healthcare system to the brink,highlighting the importance of efficient resource utilization without compromising healthcare provider safety.While advan... The coronavirus disease 2019(COVID-19)pandemic has stretched our healthcare system to the brink,highlighting the importance of efficient resource utilization without compromising healthcare provider safety.While advanced imaging is a great resource for diagnostic purposes,the risk of contamination and infection transmission is high and requires extensive logistical planning for intrahospital patient transport,healthcare provider safety,and post-imaging decontamination.This dilemma has necessitated the transition to more bedside imaging.More so than ever,during the current pandemic,the clinical utility and importance of point-of-care ultrasound(POCUS)cannot be overstressed.It allows for safe and efficient beside procedural guidance and provides front line providers with valuable diagnostic information that can be acted upon in real-time for immediate clinical decision-making.The authors have been routinely using POCUS for the management of COVID-19 patients both in the emergency department and in intensive care units turned into“COVID-units.”In this article,we review the nuances of using POCUS in a pandemic situation and maximizing diagnostic output from this bedside technology.Additionally,we review various methods and diagnostic uses of POCUS which can replace conventional imaging and bridge current literature and common clinical practices in critically ill patients.We discuss practical guidance and pertinent review of the literature for the most relevant procedural and diagnostic guidance of respiratory illness,hemodynamic decompensation,renal failure,and gastrointestinal disorders experienced by many patients admitted to COVID-units. 展开更多
关键词 COVID-19 SARS-CoV-2 point-of-care ultrasound COVID-intensive care units COVID-unit Critical care DECONTAMINATION PANDEMIC Imaging in COVID-19 point-of-care ultrasound in a pandemic
下载PDF
Effect of Point-of-care Hemoglobin/Hematocrit Devices and Autologous Blood Salvage on Reduction of Perioperative Allogeneic Blood Transfusion 被引量:4
11
作者 Wei-yun Chen Xue-rong Yu +2 位作者 Jiao Zhang Qing Yuan Yu-guang Huang 《Chinese Medical Sciences Journal》 CAS CSCD 2016年第2期83-88,共6页
Objective To evaluate the effect of point-of-care hemoglobin/hematocrit(POC HGB/HCT) devices and intraoperative blood salvage on the amount of perioperative allogeneic blood transfusion and blood conservation in clini... Objective To evaluate the effect of point-of-care hemoglobin/hematocrit(POC HGB/HCT) devices and intraoperative blood salvage on the amount of perioperative allogeneic blood transfusion and blood conservation in clinical practice. Methods A total of 46 378 medical records of 22 selected hospitals were reviewed. The volume of allogeneic red blood cell and plasma, number of patients transfused, number of intraoperative autologous blood salvage, total volume of autologous blood transfusion, and amount of surgery in the year of 2011 and 2013 were tracked. Paired t-test was used in intra-group comparison, while t-test of two isolated samples carried out in inter-group comparison. P<0.05 was defined as statistically significant difference. Results In the hospitals where POC HGB/HCT device was used(n=9), the average allogeneic blood transfusion volume per 100 surgical cases in 2013 was significantly lower than that in 2011(39.86±20.20 vs. 30.49±17.50 Units, t=3.522, P=0.008). In the hospitals without POC HGB/HCT meter, the index was not significantly different between 2013 and 2011. The average allogeneic blood transfusion volume was significantly reduced in 2013 than in 2011 in the hospitals where intraoperative autologous blood salvage ratio [autologous transfusion volume/(autologous transfusion volume+allogeneic transfusion volume)] was increased(n=12, t=2.290, P=0.042). No significant difference of the above index was found in the hospitals whose autologous transfusion ratio did not grow. Conclusion Intraoperative usage of POC HGB/HCT devices and increasing autologous transfusion ratio could reduce perioperative allogeneic blood transfusion. 展开更多
关键词 point-of-care hemoglobin/hematocrit devices AUTOLOGOUS BLOOD TRANSFUSION BLOOD management red BLOOD cell TRANSFUSION TRANSFUSION practices
下载PDF
Wave-shaped microfluidic chip assisted point-of-care testing for accurate and rapid diagnosis of infections 被引量:4
12
作者 Bin-Feng Yin Xin-Hua Wan +2 位作者 Ming-Zhu Yang Chang-Cheng Qian A.S.M.Muhtasim Fuad Sohan 《Military Medical Research》 SCIE CAS CSCD 2022年第5期553-564,共12页
Background:Early diagnosis and classification of infections increase the cure rate while decreasing complications,which is significant for severe infections,especially for war surgery.However,traditional methods rely ... Background:Early diagnosis and classification of infections increase the cure rate while decreasing complications,which is significant for severe infections,especially for war surgery.However,traditional methods rely on laborious operations and bulky devices.On the other hand,point-of-care(POC)methods suffer from limited robustness and accuracy.Therefore,it is of urgent demand to develop POC devices for rapid and accurate diagnosis of infections to fulfill on-site militarized requirements.Methods:We developed a wave-shaped microfluidic chip(WMC)assisted multiplexed detection platform(WMC-MDP).WMC-MDP reduces detection time and improves repeatability through premixing of the samples and reaction of the reagents.We further combined the detection platform with the streptavidin–biotin(SA-B)amplified system to enhance the sensitivity while using chemiluminescence(CL)intensity as signal readout.We realized simultaneous detection of C-reactive protein(CRP),procalcitonin(PCT),and interleukin-6(IL-6)on the detection platform and evaluated the sensitivity,linear range,selectivity,and repeatability.Finally,we finished detecting 15 samples from volunteers and compared the results with commercial ELISA kits.Results:Detection of CRP,PCT,and IL-6 exhibited good linear relationships between CL intensities and concentrations in the range of 1.25–40μg/ml,0.4–12.8 ng/ml,and 50–1600 pg/ml,respectively.The limit of detection of CRP,PCT,and IL-6 were 0.54μg/ml,0.11 ng/ml,and 16.25 pg/ml,respectively.WMC-MDP is capable of good adequate selectivity and repeatability.The whole detection procedure takes only 22 min that meets the requirements of a POC device.Results of 15 samples from volunteers were consistent with the results detected by commercial ELISA kits.Conclusions:WMC-MDP allows simultaneous,rapid,and sensitive detection of CRP,PCT,and IL-6 with satisfactory selectivity and repeatability,requiring minimal manipulation.However,WMC-MDP takes advantage of being a microfluidic device showing the coefficients of variation less than 10%enabling WMC-MDP to be a type of point-of-care testing(POCT).Therefore,WMC-MDP provides a promising alternative to POCT of multiple biomarkers.We believe the practical application of WMC-MDP in militarized fields will revolutionize infection diagnosis for soldiers. 展开更多
关键词 point-of-care testing(POCT) Infection markers Wave-shaped microfluidic chip CHEMILUMINESCENCE Multiplex detection
下载PDF
Perihepatic nodes detected by point-of-care ultrasound in acute hepatitis and acute-on-chronic liver disease 被引量:3
13
作者 I Che Feng Szu Jen Wang +5 位作者 Ming Jen Sheu Lok-Beng Koay Ching Yih Lin Chung Han Ho Chi Shu Sun Hsing Tao Kuo 《World Journal of Gastroenterology》 SCIE CAS 2015年第44期12620-12627,共8页
AIM: To study the manifestations of perihepatic lymph nodes during the episode of acute hepatitis flare by point-of-care ultrasonography.METHODS: One hundred and seventy-six patients with an episode of acute hepatitis... AIM: To study the manifestations of perihepatic lymph nodes during the episode of acute hepatitis flare by point-of-care ultrasonography.METHODS: One hundred and seventy-six patients with an episode of acute hepatitis flare(ALT value > 5 × upper normal limit) were enrolled retrospectively. Diagnosis of etiology of the acute hepatitis flare was based on chart records and serological and virological assays. The patients were categorized into two groups(viral origin and non-viral origin) and further defined into ten subgroups according to the etiologies. An ultrasonograpy was performed within 2 h to 72 h(median, 8 h). The maximum size of each noticeable lymph node was measured. Correlation between clinical parameters and nodal manifestations was analyzed RESULTS: Enlarged lymph nodes(width ≥ 5mm)were noticeable in 110(62.5%) patients, mostly in acute on chronic hepatitis B(54.5%). The viral group had a higher prevalence rate(89/110 = 80.9%) and larger nodal size(median, 7 mm) than those of the non-viral group(21/66 = 31.8%; median, 0 mm)(P < 0.001 for both). Meanwhile, there were significant differences in the nodal size between acute and chronic viral groups(P < 0.01), and between acute hepatitis A and non-hepatitis A viral groups(P < 0.001). In logistical regression analysis, the nodal width still showed strong significance in multivariate analysis(P < 0.0001) to stratify the two groups. The area under the curve of ROC was 0.805, with a sensitivity of 80.9%, a specificity of 68.2%, positive predictive value of 80.92%, negative predictive value of 68.18%, and an accuracy of 76.14%. CONCLUSION: Point-of-care ultrasonography to detect perihepatic nodal change is valuable for clarifying the etiologies in an episode of acute hepatitis flare. 展开更多
关键词 point-of-care ULTRASONOGRAPHY Perihepatic LYMPH no
下载PDF
What is the ideal approach for emergent pericardiocentesis using point-of-care ultrasound guidance? 被引量:3
14
作者 Lori Stolz Elaine Situ-LaCasse +5 位作者 Josie Acuña Matthew Thompson Nicolaus Hawbaker Josephine Valenzuela Uwe Stolz Srikar Adhikari 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2021年第3期169-173,共5页
BACKGROUND:Traditionally performed using a subxiphoid approach,the increasing use of point-of-care ultrasound in the emergency department has made other approaches(parasternal and apical)for pericardiocentesis viable.... BACKGROUND:Traditionally performed using a subxiphoid approach,the increasing use of point-of-care ultrasound in the emergency department has made other approaches(parasternal and apical)for pericardiocentesis viable.The aim of this study is to identify the ideal approach for emergency-physician-performed ultrasound-guided pericardiocentesis as determined by ultrasound image quality,distance from surface to pericardial fl uid,and likely obstructions or complications.METHODS:A retrospective review of point-of-care cardiac ultrasound examinations was performed in two urban academic emergency departments for the presence of pericardial eff usions.The images were reviewed for technical quality,distance of eff usion from skin surface,and predicted complications.RESULTS:A total of 166 pericardial effusions were identified during the study period.The mean skin-to-pericardial fl uid distance was 5.6 cm(95%confi dence interval[95%CI]5.2-6.0 cm)for the subxiphoid views,which was signifi cantly greater than that for the parasternal(2.7 cm[95%CI 2.5-2.8 cm],P<0.001)and apical(2.5 cm[95%CI 2.3-2.7 cm],P<0.001)views.The subxiphoid view had the highest predicted complication rate at 79.7%(95%CI 71.5%-86.4%),which was signifi cantly greater than the apical(31.9%;95%CI 21.4%-44.0%,P<0.001)and parasternal(20.2%;95%CI 12.8%-29.5%,P<0.001)views.CONCLUSIONS:Our results suggest that complication rates with pericardiocentesis will be lower via the parasternal or apical approach compared to the subxiphoid approach.The distance from skin to fl uid collection is the least in both of these views. 展开更多
关键词 PERICARDIOCENTESIS Pericardial effusion point-of-care ultrasound Emergency department Subxiphoid Parasternal APICAL
下载PDF
Utility of point-of-care musculoskeletal ultrasound in the evaluation of emergency department musculoskeletal pathology 被引量:5
15
作者 Elaine Situ-LaCasse Ryan W. Grieger +3 位作者 Stephen Crabbe Anna L. Waterbrook Lucas Friedman Srikar Adhikari 《World Journal of Emergency Medicine》 SCIE CAS 2018年第4期262-266,共5页
BACKGROUND: To evaluate the utilization of point-of-care ultrasound(POCUS) for the assessment of emergency department(ED) patients with musculoskeletal symptoms and the impact of musculoskeletal POCUS on medical decis... BACKGROUND: To evaluate the utilization of point-of-care ultrasound(POCUS) for the assessment of emergency department(ED) patients with musculoskeletal symptoms and the impact of musculoskeletal POCUS on medical decision-making and patient management in the ED.METHODS: This was a retrospective review of ED patients presenting with musculoskeletal symptoms who received a POCUS over a 3.5-year period. An ED POCUS database was reviewed for musculoskeletal POCUS examinations used for medical decision-making. Electronic medical records were then reviewed for demographic characteristics, history, physical examination findings, ED course, additional imaging studies, and impact of musculoskeletal POCUS on patient management in ED. RESULTS: A total of 264 subjects(92 females, 172 males) and 292 musculoskeletal POCUS examinations were included in the fi nal analysis. Most common symptomatic sites were knee(31.8%) and ankle(16.3%). Joint effusion was the most common fi nding on musculoskeletal POCUS, noted in 33.7% of the patients, and subcutaneous edema/cobblestoning was found in 10.2% of the patients. Muscle or tendon rupture was found in 2.3% of the patients, and 1.9% of the patients had joint dislocation. Bursitis or bursa fluid was found in 3.4% of patients, and tendonitis/tendinopathy was found in 2.3%. Twenty percent of them were ultrasound-guided musculoskeletal procedures, and most of them(73.3%) were arthrocentesis. Of the included studies, all except three either changed or helped guide patient management as documented in the patients' medical records.CONCLUSION: Our study fi ndings illustrate the utility of POCUS in the evaluation of a variety of musculoskeletal pathologies in the ED. 展开更多
关键词 point-of-care ultrasound MUSCULOSKELETAL Emergency department
下载PDF
Delayed cardiac tamponade diagnosed by point-of-care ultrasound in a neonate after peripherally inserted central catheter placement: A case report 被引量:4
16
作者 Yu Cui Kai Liu +1 位作者 Liming Luan Peng Liang 《World Journal of Clinical Cases》 SCIE 2021年第3期602-606,共5页
BACKGROUND Peripherally inserted central catheters(PICCs)have been increasingly applied worldwide owing to many advantages.Even with these advantages,the related complications should not be ignored,especially in neona... BACKGROUND Peripherally inserted central catheters(PICCs)have been increasingly applied worldwide owing to many advantages.Even with these advantages,the related complications should not be ignored,especially in neonates.The available evidence about PICC-related thrombosis was manifold,but the cardiac tamponade,an emergency and life-threatening complication,has been rarely reported.Early recognized cardiac tamponade by ultrasound may reduce mortality.CASE SUMMARY A neonate weighting 2.8 kg was born at 40 wk of gestation.He was admitted to the Surgery Intensive Care Unit due to suspected congenital megacolon.A PICC line was inserted via the left antecubital fossa for the administration of total parenteral nutrition.Three days later,the patient was still on total parenteral nutrition.Cardiac tamponade caused by PICC was found on ultrasound.The patient recovered spontaneously after an emergency pericardiocentesis.CONCLUSION Proficiency in the use of point-of-care ultrasound may save the life of patients,since it enables clinicians to treat patients faster,more accurately,and in a noninvasive way at the point of care. 展开更多
关键词 Peripherally inserted central catheters point-of-care ultrasound NEONATES Delayed cardiac tamponade Case report
下载PDF
Smartphone-based cytometric biosensors for point-of-care cellular diagnostics 被引量:2
17
作者 Shengwei Zhang Zheng Li Qingshan Wei 《Nanotechnology and Precision Engineering》 EI CAS CSCD 2020年第1期32-42,共11页
Analysis on a single-cell basis is both fundamental and meaningful in biomedical research and clinical practice.Flow cytometry is one of the most popular approaches in this field with broad applications in cell sortin... Analysis on a single-cell basis is both fundamental and meaningful in biomedical research and clinical practice.Flow cytometry is one of the most popular approaches in this field with broad applications in cell sorting,counting,and identification of rare cells.However,the complicated design and bulky size of conventional flow cytometry have restricted their applications mainly in centralized laboratories.With the recent development of smartphone devices,smartphone-based cytometry has been explored and tested for single-cell analysis.Compared with traditional cytometers,smartphone-based cytometric biosensors are more suitable for point-of-care(POC)uses,such as on-site disease diagnosis and personal health monitoring.In this review article,the history of traditional flowcytometry is introduced,and advances of smartphone-enabled cytometry are summarized in detail based on different working principles.Representative POC applications of smartphone cytometers are also discussed.The achievements demonstrated so far illustrate the potential of smartphone-based cytometric devices to transform single-cell measurement in general,with a significant impact in POC diagnostics,preventive medicine,and cell biology. 展开更多
关键词 Flow CYTOMETRY SMARTPHONE point-of-care DIAGNOSTICS SINGLE-CELL analysis Imaging MICROFLUIDICS
下载PDF
Nanozymes in Point-of-Care Diagnosis:An Emerging Futuristic Approach for Biosensing 被引量:2
18
作者 Bhaskar Das Javier Lou Franco +3 位作者 Natasha Logan Paramasivan Balasubramanian Moon Il Kim Cuong Cao 《Nano-Micro Letters》 SCIE EI CAS CSCD 2021年第12期44-94,共51页
Nanomaterial-based artificial enzymes(or nanozymes) have attracted great attention in the past few years owing to their capability not only to mimic functionality but also to overcome the inherent drawbacks of the nat... Nanomaterial-based artificial enzymes(or nanozymes) have attracted great attention in the past few years owing to their capability not only to mimic functionality but also to overcome the inherent drawbacks of the natural enzymes.Numerous advantages of nanozymes such as diverse enzyme-mimicking activities,low cost,high stability,robustness,unique surface chemistry,and ease of surface tunability and biocompatibility have allowed their integration in a wide range of biosensing applications. Several metal,metal oxide,metal–organic framework-based nanozymes have been exploited for the development of biosensing systems,which present the potential for point-of-care analysis. To highlight recent progress in the field,in this review,more than 260 research articles are discussed systematically with suitable recent examples,elucidating the role of nanozymes to reinforce,miniaturize,and improve the performance of point-of-care diagnostics addressing the ASSURED(a ordable,sensitive,specific,user-friendly,rapid and robust,equipment-free and deliverable to the end user) criteria formulated by World Health Organization. The review reveals that many biosensing strategies such as electrochemical,colorimetric,fluorescent,and immunological sensors required to achieve the ASSURED standards can be implemented by using enzyme-mimicking activities of nanomaterials as signal producing components. However,basic system functionality is still lacking. Since the enzyme-mimicking properties of the nanomaterials are dictated by their size,shape,composition,surface charge,surface chemistry as well as external parameters such as pH or temperature,these factors play a crucial role in the design and function of nanozyme-based point-of-care diagnostics. Therefore,it requires a deliberate exertion to integrate various parameters for truly ASSURED solutions to be realized. This review also discusses possible limitations and research gaps to provide readers a brief scenario of the emerging role of nanozymes in state-of-the-art POC diagnosis system development for futuristic biosensing applications. 展开更多
关键词 Nanozymes BIOSENSING point-of-care diagnosis ASSURED diagnostics Catalytic nanomaterials
下载PDF
Surgeon-performed point-of-care ultrasound in severe eye trauma: Report of two cases 被引量:1
19
作者 Fikri M Abu-Zidan Korana Balac Chetana Anand Bhatia 《World Journal of Clinical Cases》 SCIE 2016年第10期344-350,共7页
The indications of point-of-care ultrasound(POCUS) in the management of multiple trauma patients have been expanding. Although computed tomography(CT) scan of the orbit remains the gold standard for imaging orbital tr... The indications of point-of-care ultrasound(POCUS) in the management of multiple trauma patients have been expanding. Although computed tomography(CT) scan of the orbit remains the gold standard for imaging orbital trauma, ultrasound is a quick, safe, and portable tool that can be performed bedside. Here we report two patients who had severe eye injuries with major visual impairment where surgeon-performed POCUS was very useful. One had a foreign body injury while the other had blunt trauma. POCUS was done using a linear probe under sterile conditions with minimum pressure on the eyes. Ultrasound showed a foreign body at the back of the left eye globe touching the eye globe in the first patient, and was normal in the second patient. Workup using CT scan, fundsocopy, optical coherence tomography, and magnetic resonance imaging of the orbits confirmed these findings. The first patient had vitreous and sub retinal haemorrhage and a full thickness macular hole of the left eye, while the second had traumatic optic neuropathy. POCUS gave accurate information concerning severe eye injuries. Trauma surgeons and emergency physicians should be trained in performing ocular ultrasound for eye injuries. 展开更多
关键词 Eye INJURY TRAUMA point-of-care ULTRASOUND
下载PDF
Simpli?ed point-of-care ultrasound protocol to con?rm central venous catheter placement:A prospective study 被引量:2
20
作者 Scan P.Wilson Samer Assaf +6 位作者 Shadi Lahham Mohammad Subeh Alan Chiem Craig Anderson Samantha Shwe Ryan Nguyen John C.Fox 《World Journal of Emergency Medicine》 CAS 2017年第1期25-28,共4页
BACKGROUND: The current standard for con? rmation of correct supra-diaphragmatic central venous catheter(CVC) placement is with plain ? lm chest radiography(CXR). We hypothesized that a simple point-of-care ultrasound... BACKGROUND: The current standard for con? rmation of correct supra-diaphragmatic central venous catheter(CVC) placement is with plain ? lm chest radiography(CXR). We hypothesized that a simple point-of-care ultrasound(POCUS) protocol could effectively con? rm placement and reduce time to con? rmation.METHODS: We prospectively enrolled a convenience sample of patients in the emergency department and intensive care unit who required CVC placement. Correct positioning was considered if turbulent flow was visualized in the right atrium on sub-xiphoid, parasternal or apical cardiac ultrasound after injecting 5 cc of sterile, non-agitated, normal saline through the CVC.RESULTS: Seventy-eight patients were enrolled. POCUS had a sensitivity of 86.8%(95%CI 77.1%–93.5%) and speci? city of 100%(95%CI 15.8%–100.0%) for identifying correct central venous catheter placement. Median POCUS and CXR completion were 16 minutes(IQR 10–29) and 32 minutes(IQR 19–45), respectively.CONCLUSION: Ultrasound may be an effective tool to confirm central venous catheter placement in instances where there is a delay in obtaining a con? rmatory CXR. 展开更多
关键词 point-of-care ultrasound Emergency ultrasound Central venous access
下载PDF
上一页 1 2 7 下一页 到第
使用帮助 返回顶部