A frequency servo system-on-chip(FS-SoC)featuring output power stabilization technology is introduced in this study for high-precision and miniaturized cesium(Cs)atomic clocks.The proposed power stabilization loop(PSL...A frequency servo system-on-chip(FS-SoC)featuring output power stabilization technology is introduced in this study for high-precision and miniaturized cesium(Cs)atomic clocks.The proposed power stabilization loop(PSL)technique,incorporating an off-chip power detector(PD),ensures that the output power of the FS-SoC remains stable,mitigating the impact of power fluctuations on the atomic clock's stability.Additionally,a one-pulse-per-second(1PPS)is employed to syn-chronize the clock with GPS.Fabricated using 65 nm CMOS technology,the measured phase noise of the FS-SoC stands at-69.5 dBc/Hz@100 Hz offset and-83.9 dBc/Hz@1 kHz offset,accompanied by a power dissipation of 19.7 mW.The Cs atomic clock employing the proposed FS-SoC and PSL obtains an Allan deviation of 1.7×10^(-11) with 1-s averaging time.展开更多
This paper presents a new concept for damping electro-mechanical oscillations in large turbo generator. The proposed concept is based on coordination between Power System Stabilizer (PSS) and Thyristor Controlled Br...This paper presents a new concept for damping electro-mechanical oscillations in large turbo generator. The proposed concept is based on coordination between Power System Stabilizer (PSS) and Thyristor Controlled Braking Resistor (TCBR). This coordination will enhance the stability of the inertial and torsional oscillatory modes. The study is performed on system-I of the second IEEE benchmark for simulation of Sub-Synchronous Oscillations, using eigenvalue analysis and verified by detailed digital simulation. A dynamic fundamental frequency model for TCBR is developed. The pole placement technique is used to design the control system of TCBR and PSS. The shaft torque's following a disturbance is computed and analyzed. The obtained results indicate that substantial damping is achieved by the proposed coordination.展开更多
A novel technique for the optimal tuning of power system stabilizer (PSS) was proposed,by integrating the modified particle swarm optimization (MPSO) with the chaos (MPSOC).Firstly,a modification in the particle swarm...A novel technique for the optimal tuning of power system stabilizer (PSS) was proposed,by integrating the modified particle swarm optimization (MPSO) with the chaos (MPSOC).Firstly,a modification in the particle swarm optimization (PSO) was made by introducing passive congregation (PC).It helps each swarm member in receiving a multitude of information from other members and thus decreases the possibility of a failed attempt at detection or a meaningless search.Secondly,the MPSO and chaos were hybridized (MPSOC) to improve the global searching capability and prevent the premature convergence due to local minima.The robustness of the proposed PSS tuning technique was verified on a multi-machine power system under different operating conditions.The performance of the proposed MPSOC was compared to the MPSO,PSO and GA through eigenvalue analysis,nonlinear time-domain simulation and statistical tests.Eigenvalue analysis shows acceptable damping of the low-frequency modes and time domain simulations also show that the oscillations of synchronous machines can be rapidly damped for power systems with the proposed PSSs.The results show that the presented algorithm has a faster convergence rate with higher degree of accuracy than the GA,PSO and MPSO.展开更多
为了演示和验证稳定器设计的就地相位补偿法在多机电力系统中的应用,介绍在多机电力系统中,就地补偿设计稳定器的2个应用实例。第1个实例是在多机电力系统中就地补偿设计电力系统稳定器(power system stabilizer,PSS),阻尼电力系统局...为了演示和验证稳定器设计的就地相位补偿法在多机电力系统中的应用,介绍在多机电力系统中,就地补偿设计稳定器的2个应用实例。第1个实例是在多机电力系统中就地补偿设计电力系统稳定器(power system stabilizer,PSS),阻尼电力系统局部模振荡。第2个实例是就地补偿设计附加在静态同步补偿器(static synchronous compensator,STATCOM)上的稳定器,抑制多机电力系统中的区域模振荡,并给出在一个16机电力系统中的应用计算和仿真结果。展开更多
The voltagefluctuation in electric circuits has been identified as key issue in different electric systems.As the usage of electricity growing in rapid way,there exist higherfluctuations in powerflow.To maintain theflow or...The voltagefluctuation in electric circuits has been identified as key issue in different electric systems.As the usage of electricity growing in rapid way,there exist higherfluctuations in powerflow.To maintain theflow or stabi-lity of power in any electric circuit,there are many circuit models are discussed in literature.However,they suffer to maintain the output voltage and not capable of maintaining power stability.To improve the performance in power stabilization,an efficient IC pattern based power factor maximization model(ICPFMM)in this article.The model is focused on improving the power stability with the use of IC(Inductor and Conductor)towards identifying most efficient circuit for the current duty cycle according to the input voltage,voltage in capacitor and output voltage required.The model with boost converter diverts the incoming voltage through number of conductors and inductors.By triggering specific inductor,a specific capacitor gets charged and a particular circuit gets on.The model maintains num-ber of IC(Inductor and Conductor)patterns through which the powerflow occurs.According to that,the pattern available,the mofset controls the level of power to be regulated through any circuit.From the pattern,the model computes the Cir-cuits Switching Loss and Circuits Conduction Loss for various circuits.Accord-ing to the input voltage,the model estimates Circuit Power Stabilization Support(CPSS)according to the voltage available in any capacitor and input voltage.Using the value of CPSS,the model trigger optimal number of circuits to maintain voltage stability.In this approach,more than one circuit has been triggered to maintain output voltage and to get charged.The proposed model not only main-tains power stability but also reduces the wastage in voltage which is not utilized.The proposed model improves the performance in voltage stability with less switching loss.展开更多
In this paper, Power System Stabilizer (PSS) and Automatic Voltage Regulator (AVR) are coordinated to improve the transient stability of generator in power system. Coordinated design problem of AVR and PSS is formulat...In this paper, Power System Stabilizer (PSS) and Automatic Voltage Regulator (AVR) are coordinated to improve the transient stability of generator in power system. Coordinated design problem of AVR and PSS is formulated as an optimization problem. Particle Swarm Optimization (PSO) technique is an advanced robust search method by the swarming or cooperative behavior of biological populations mechanism. The performance of PSO has been certified in solution of highly non-linear objectives. Thus, PSO technique has been employed to optimize the parameters of PSS and AVR in order to reduce the power system oscillations during the load changing conditions in single-machine, infinite-bus power system. The results of nonlinear simulation suggest that, by coordinated design of AVR and PSS based on PSO technique power system oscillations are exceptionally damped. Correspondingly, it’s shown that power system stability is superiorly enhanced than the uncoordinated designed of the PSS and the AVR controllers.展开更多
目的为了整体改善多机电力系统的功角和电压振荡特性,方法在包含电力系统稳定器(power system stabilizer,PSS)的多机系统中引入电力系统电压调节器(power system voltage regulator,PSVR),考虑电压振荡模式与功角振荡模式的相互影响,...目的为了整体改善多机电力系统的功角和电压振荡特性,方法在包含电力系统稳定器(power system stabilizer,PSS)的多机系统中引入电力系统电压调节器(power system voltage regulator,PSVR),考虑电压振荡模式与功角振荡模式的相互影响,合理整定PSVR参数。本文首先采用相频特性分析法和根轨迹法选择PSS与PSVR的参数初值;其次以控制器的增益系数和时间常数为控制变量,系统功角振荡模式和电压振荡模式的稳定性指标为优化目标,控制器参数取值范围为约束条件,建立多机系统PSS与PSVR的参数联合优化模型;最后采用非线性规划方法求解。结果通过实际算例分析,经过协调优化PSS与PSVR参数,系统的功角振荡模式和电压振荡模式得到了改善,二者阻尼比均能达到期望水平。在8机系统中,经过优化最小阻尼功角模式的阻尼比由0.0841变为0.1029,最小阻尼电压模式的阻尼比由0.0475变为0.0911;在某实际系统算例中,优化后功角、电压振荡模式中的最小阻尼模式也均能满足阈值要求。结论在包含PSS的多机系统中引入PSVR,利用本文所提多机系统PSS与PSVR参数联合优化模型,可以整体改善系统的功角和电压振荡特性。展开更多
Perovskite solar cells(PSCs)have emerged as a promising photovoltaic technology because of their high light absorption coefficient,long carrier diffusion distance,and tunable bandgap.However,PSCs face challenges such ...Perovskite solar cells(PSCs)have emerged as a promising photovoltaic technology because of their high light absorption coefficient,long carrier diffusion distance,and tunable bandgap.However,PSCs face challenges such as hysteresis effects and stability issues.In this study,we introduced a novel approach to improve film crystallization by leveraging 4-tert-butylpyridine(TBP)molecules,thereby enhancing the performance and stability of PSCs.Our findings demonstrate the effective removal of PbI_(2)from the perovskite surface through strong coordination with TBP molecules.Additionally,by carefully adjusting the concentration of the TBP solution,we achieved enhanced film crystallinity without disrupting the perovskite structure.The TBP-treated perovskite films exhibit a low defect density,improved crystallinity,and improved carrier lifetime.As a result,the PSCs manufactured with TBP treatment achieve power conversion efficiency(PCE)exceeding 24%.Moreover,we obtained the PCE of 21.39%for the 12.25 cm^(2)module.展开更多
For solving the dynamic instability problem of Yunnan Provincial Power System (YNPS) and the South China Interconnected Power System (SCIPS), Lubuge Hydropower Station was chosen to install Power System Stabilizer (PS...For solving the dynamic instability problem of Yunnan Provincial Power System (YNPS) and the South China Interconnected Power System (SCIPS), Lubuge Hydropower Station was chosen to install Power System Stabilizer (PSS). This paper introduces the principles and methods of parameter selection for PSS, in addition to field test. The test results show that the PSS installed can significantly improve the system damping.展开更多
High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is...High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is becoming more and more vital for the development of wind power.The HFO phenomenon of wind turbines under different scenarios usually has different mechanisms.Hence,engineers need to acquire the working mechanisms of the different HFO damping technologies and select the appropriate one to ensure the effective implementation of oscillation damping in practical engineering.This paper introduces the general assumptions of WPGS when analyzing HFO,systematically summarizes the reasons for the occurrence of HFO in different scenarios,deeply analyses the key points and difficulties of HFO damping under different scenarios,and then compares the technical performances of various types of HFO suppression methods to provide adequate references for engineers in the application of technology.Finally,this paper discusses possible future research difficulties in the problem of HFO,as well as the possible future trends in the demand for HFO damping.展开更多
In this paper, the Authors present the designing of power system stabilizer (PSS) and static var compensator (SVC) based on chaos, particle swarm optimization (PSO) and shuffled frog leaping (SFL) Algorithms has been ...In this paper, the Authors present the designing of power system stabilizer (PSS) and static var compensator (SVC) based on chaos, particle swarm optimization (PSO) and shuffled frog leaping (SFL) Algorithms has been presented to improve the power system stability. Single machine infinite bus (SMIB) system with SVC located at the terminal of generator has been considered to evaluate the proposed SVC and PSS controllers. The coefficients of PSS and SVC controller have been optimized by Chaos, PSO and SFL algorithms. Fi-nally the system with proposed controllers is simulated for the special disturbance in input power of genera-tor, and then the dynamic responses of generator have been presented. The simulation results show that the system composed with recommended controller has outstanding operation in fast damping of oscillations of power system and describes an application of Chaos, PSO and SFL algorithms to the problem of designing a Lead-Lag controller used in PSS and SVC in power system.展开更多
One method for eliminating oscillations in power systems is using stabilizers.By applying an appropriate control signal in the excitation system of a generator,a power system stabilizer improves the dynamic stability ...One method for eliminating oscillations in power systems is using stabilizers.By applying an appropriate control signal in the excitation system of a generator,a power system stabilizer improves the dynamic stability of power systems.However,the issue that is of high importance is the correct design of these stabilizers.These stabilizers must be designed to have proper performance when operating conditions change.When designed incorrectly,not only they do not improve the stability margin,but also increase the oscillations.In this paper,the robust design of power system stabilizers on a four-machine power system has been performed.For this purpose,the differential evolution algorithm has been used.The studies have been repeated as three scenarios by producing different loading conditions for the generators.The performances of the conventional stabilizer and the optimized one have been compared.Simulation results indicate that the designed robust stabilizer outperforms other stabilizers in different conditions and has damped the interarea and intra-area oscillation modes in the shortest time with minimum amplitude.展开更多
This research paper deals with the identification of the best location of the Power System Stabilizers (PSS) and also the tuning of PSS parameters in order to improve the overall dynamic stability of multi machine pow...This research paper deals with the identification of the best location of the Power System Stabilizers (PSS) and also the tuning of PSS parameters in order to improve the overall dynamic stability of multi machine power systems. The location of PSS is determined by identifying the critical modes and their corresponding first and second order eigenvalue sensitivities. In this formulation, sensitivity analysis of a particular mode can be performed with only its eigenvalues and their left and right eigenvectors. The simplicity and efficiency of this approach sharply contrast to the complexity of the traditional approach, where all eigenvalues and eigenvectors are required at the same time. The effectiveness of this method in selecting the optimum location for placement of PSSs is compared with the participation factor method. The proposed sensitivity theory used to identify the best PSS location in a five machine, eight bus El-Metwally and Malik System to increase the damping of both local and inter area modes for various operating conditions.展开更多
In themarine electric power system,the marine generators will be disturbed by the large change of loads or the fault of the power system.The marine generators usually installed power system stabilizers to damp power s...In themarine electric power system,the marine generators will be disturbed by the large change of loads or the fault of the power system.The marine generators usually installed power system stabilizers to damp power system oscillations through the excitation control.This paper proposes a novel method to obtain optimal parameter values for Power System Stabilizer(PSS)to suppress low-frequency oscillations in the marine electric power system.In this paper,a newly developed immune clone selection algorithm was improved from the three aspects of the adaptive incentive degree,vaccination,and adaptive mutation strategies.Firstly,the typical PSS implementation type of leader-lag structure was adopted and the objective function was set in the optimization process.The performance of PSS tuned by improved immune clone selection algorithm was compared with PSS tuned by basic immune clone selection algorithm(ICSA)under various operating conditions and disturbances.Then,an improved immune clone selection algorithm(IICSA)optimization technique was implemented on two test systems for test purposes.Based on the simulations,it is found that an improved immune clone selection algorithm demonstrates superiority over the basic immune clone selection algorithm in getting a smaller number of iterations and fast convergence rates to achieve the optimal parameters of the power system stabilizers.Moreover,the proposed approach improves the stability and dynamic performance under various loads conditions and disturbances of the marine electric power system.展开更多
In this paper, we examine the problem of designing power system stabilizer (PSS). A new technique is developed using particle swarm optimization (PSO) combined with linear matrix inequality (LMI). The main feature of ...In this paper, we examine the problem of designing power system stabilizer (PSS). A new technique is developed using particle swarm optimization (PSO) combined with linear matrix inequality (LMI). The main feature of PSO, not sticking into a local minimum, is used to eliminate the conservativeness of designing a static output feedback (SOF) stabilizer within an iterative solution of LMIs. The technique is further extended to guarantee robustness against uncertainties wherein power systems operation is changing continuously due to load changes. Numerical simulation ahs illustrated the utility of the developed technique.展开更多
This paper presents an analysis of the power flow within the Northern Interconnected Grid of Cameroon. The Newton-Raphson method has been performed, known for its accuracy, under MATLAB software, to model and solve co...This paper presents an analysis of the power flow within the Northern Interconnected Grid of Cameroon. The Newton-Raphson method has been performed, known for its accuracy, under MATLAB software, to model and solve complex power flow equations. This study simulates a series of outage scenarios to evaluate the responsiveness of the grid. The results obtained underline the crucial importance of reactive power management and highlight the urgent need to consolidate the grid infrastructure of North Cameroon. To increase grid resilience and stability, the paper recommends the strategic integration of renewables and the development of interconnections with other power grids. These measures are presented as viable solutions to meet current and future energy distribution challenges, ensuring a reliable and sustainable power supply for Cameroon.展开更多
This paper proposes a robust power system stabilizer(PSS)for a steam synchronous generator in Barka II power station.The PSS should be capable of damping small-disturbance oscillations(inherently existing in power sys...This paper proposes a robust power system stabilizer(PSS)for a steam synchronous generator in Barka II power station.The PSS should be capable of damping small-disturbance oscillations(inherently existing in power systems due to e.g.load changes,lines switching...etc.)within a certain settling time for different load conditions.Also,the proposed PSS must have the conventional structure and its parameters must not be violated.To achieve this goal,robust control provides many advantages.The suggested controller is tuned by the Kharitonov’s theorem and uses the standard structure employed in industry.The problem is cast into a nonlinear constrained optimization problem to achieve the desired settling time without violating the practical values of the controller parameters.Performance of the robust PSS is evaluated by several simulations in the presence of system uncertainty due to load changes.展开更多
基金supported by the National Natural Science Foundation of China under Grant 62034002 and 62374026.
文摘A frequency servo system-on-chip(FS-SoC)featuring output power stabilization technology is introduced in this study for high-precision and miniaturized cesium(Cs)atomic clocks.The proposed power stabilization loop(PSL)technique,incorporating an off-chip power detector(PD),ensures that the output power of the FS-SoC remains stable,mitigating the impact of power fluctuations on the atomic clock's stability.Additionally,a one-pulse-per-second(1PPS)is employed to syn-chronize the clock with GPS.Fabricated using 65 nm CMOS technology,the measured phase noise of the FS-SoC stands at-69.5 dBc/Hz@100 Hz offset and-83.9 dBc/Hz@1 kHz offset,accompanied by a power dissipation of 19.7 mW.The Cs atomic clock employing the proposed FS-SoC and PSL obtains an Allan deviation of 1.7×10^(-11) with 1-s averaging time.
文摘This paper presents a new concept for damping electro-mechanical oscillations in large turbo generator. The proposed concept is based on coordination between Power System Stabilizer (PSS) and Thyristor Controlled Braking Resistor (TCBR). This coordination will enhance the stability of the inertial and torsional oscillatory modes. The study is performed on system-I of the second IEEE benchmark for simulation of Sub-Synchronous Oscillations, using eigenvalue analysis and verified by detailed digital simulation. A dynamic fundamental frequency model for TCBR is developed. The pole placement technique is used to design the control system of TCBR and PSS. The shaft torque's following a disturbance is computed and analyzed. The obtained results indicate that substantial damping is achieved by the proposed coordination.
文摘A novel technique for the optimal tuning of power system stabilizer (PSS) was proposed,by integrating the modified particle swarm optimization (MPSO) with the chaos (MPSOC).Firstly,a modification in the particle swarm optimization (PSO) was made by introducing passive congregation (PC).It helps each swarm member in receiving a multitude of information from other members and thus decreases the possibility of a failed attempt at detection or a meaningless search.Secondly,the MPSO and chaos were hybridized (MPSOC) to improve the global searching capability and prevent the premature convergence due to local minima.The robustness of the proposed PSS tuning technique was verified on a multi-machine power system under different operating conditions.The performance of the proposed MPSOC was compared to the MPSO,PSO and GA through eigenvalue analysis,nonlinear time-domain simulation and statistical tests.Eigenvalue analysis shows acceptable damping of the low-frequency modes and time domain simulations also show that the oscillations of synchronous machines can be rapidly damped for power systems with the proposed PSSs.The results show that the presented algorithm has a faster convergence rate with higher degree of accuracy than the GA,PSO and MPSO.
文摘为了演示和验证稳定器设计的就地相位补偿法在多机电力系统中的应用,介绍在多机电力系统中,就地补偿设计稳定器的2个应用实例。第1个实例是在多机电力系统中就地补偿设计电力系统稳定器(power system stabilizer,PSS),阻尼电力系统局部模振荡。第2个实例是就地补偿设计附加在静态同步补偿器(static synchronous compensator,STATCOM)上的稳定器,抑制多机电力系统中的区域模振荡,并给出在一个16机电力系统中的应用计算和仿真结果。
文摘The voltagefluctuation in electric circuits has been identified as key issue in different electric systems.As the usage of electricity growing in rapid way,there exist higherfluctuations in powerflow.To maintain theflow or stabi-lity of power in any electric circuit,there are many circuit models are discussed in literature.However,they suffer to maintain the output voltage and not capable of maintaining power stability.To improve the performance in power stabilization,an efficient IC pattern based power factor maximization model(ICPFMM)in this article.The model is focused on improving the power stability with the use of IC(Inductor and Conductor)towards identifying most efficient circuit for the current duty cycle according to the input voltage,voltage in capacitor and output voltage required.The model with boost converter diverts the incoming voltage through number of conductors and inductors.By triggering specific inductor,a specific capacitor gets charged and a particular circuit gets on.The model maintains num-ber of IC(Inductor and Conductor)patterns through which the powerflow occurs.According to that,the pattern available,the mofset controls the level of power to be regulated through any circuit.From the pattern,the model computes the Cir-cuits Switching Loss and Circuits Conduction Loss for various circuits.Accord-ing to the input voltage,the model estimates Circuit Power Stabilization Support(CPSS)according to the voltage available in any capacitor and input voltage.Using the value of CPSS,the model trigger optimal number of circuits to maintain voltage stability.In this approach,more than one circuit has been triggered to maintain output voltage and to get charged.The proposed model not only main-tains power stability but also reduces the wastage in voltage which is not utilized.The proposed model improves the performance in voltage stability with less switching loss.
文摘In this paper, Power System Stabilizer (PSS) and Automatic Voltage Regulator (AVR) are coordinated to improve the transient stability of generator in power system. Coordinated design problem of AVR and PSS is formulated as an optimization problem. Particle Swarm Optimization (PSO) technique is an advanced robust search method by the swarming or cooperative behavior of biological populations mechanism. The performance of PSO has been certified in solution of highly non-linear objectives. Thus, PSO technique has been employed to optimize the parameters of PSS and AVR in order to reduce the power system oscillations during the load changing conditions in single-machine, infinite-bus power system. The results of nonlinear simulation suggest that, by coordinated design of AVR and PSS based on PSO technique power system oscillations are exceptionally damped. Correspondingly, it’s shown that power system stability is superiorly enhanced than the uncoordinated designed of the PSS and the AVR controllers.
文摘目的为了整体改善多机电力系统的功角和电压振荡特性,方法在包含电力系统稳定器(power system stabilizer,PSS)的多机系统中引入电力系统电压调节器(power system voltage regulator,PSVR),考虑电压振荡模式与功角振荡模式的相互影响,合理整定PSVR参数。本文首先采用相频特性分析法和根轨迹法选择PSS与PSVR的参数初值;其次以控制器的增益系数和时间常数为控制变量,系统功角振荡模式和电压振荡模式的稳定性指标为优化目标,控制器参数取值范围为约束条件,建立多机系统PSS与PSVR的参数联合优化模型;最后采用非线性规划方法求解。结果通过实际算例分析,经过协调优化PSS与PSVR参数,系统的功角振荡模式和电压振荡模式得到了改善,二者阻尼比均能达到期望水平。在8机系统中,经过优化最小阻尼功角模式的阻尼比由0.0841变为0.1029,最小阻尼电压模式的阻尼比由0.0475变为0.0911;在某实际系统算例中,优化后功角、电压振荡模式中的最小阻尼模式也均能满足阈值要求。结论在包含PSS的多机系统中引入PSVR,利用本文所提多机系统PSS与PSVR参数联合优化模型,可以整体改善系统的功角和电压振荡特性。
基金financial support from various entities,including the Foundation of Anhui Science and Technology University[HCYJ202201]the Anhui Science and Technology University’s Student Innovation and Entrepreneurship Training Program[S202310879115,202310879053]+4 种基金the Key Project of Natural Science Research in Anhui Science and Technology University[2021ZRZD07]the Chuzhou Science and Technology Project[2021GJ002]the Anhui Province Key Research and Development Program[202304a05020085]the Natural Science Research Project of Anhui Educational Committee[2023AH051877]The Opening Project of State Key Laboratory of Advanced Technology for Float Glass[2020KF06,2022KF06]。
文摘Perovskite solar cells(PSCs)have emerged as a promising photovoltaic technology because of their high light absorption coefficient,long carrier diffusion distance,and tunable bandgap.However,PSCs face challenges such as hysteresis effects and stability issues.In this study,we introduced a novel approach to improve film crystallization by leveraging 4-tert-butylpyridine(TBP)molecules,thereby enhancing the performance and stability of PSCs.Our findings demonstrate the effective removal of PbI_(2)from the perovskite surface through strong coordination with TBP molecules.Additionally,by carefully adjusting the concentration of the TBP solution,we achieved enhanced film crystallinity without disrupting the perovskite structure.The TBP-treated perovskite films exhibit a low defect density,improved crystallinity,and improved carrier lifetime.As a result,the PSCs manufactured with TBP treatment achieve power conversion efficiency(PCE)exceeding 24%.Moreover,we obtained the PCE of 21.39%for the 12.25 cm^(2)module.
文摘For solving the dynamic instability problem of Yunnan Provincial Power System (YNPS) and the South China Interconnected Power System (SCIPS), Lubuge Hydropower Station was chosen to install Power System Stabilizer (PSS). This paper introduces the principles and methods of parameter selection for PSS, in addition to field test. The test results show that the PSS installed can significantly improve the system damping.
基金supported in part by the Fundamental Research Funds for the Central Universities under Grant 2682023CX019National Natural Science Foundation of China under Grant U23B6007 and Grant 52307141Sichuan Science and Technology Program under Grant 2024NSFSC0115。
文摘High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is becoming more and more vital for the development of wind power.The HFO phenomenon of wind turbines under different scenarios usually has different mechanisms.Hence,engineers need to acquire the working mechanisms of the different HFO damping technologies and select the appropriate one to ensure the effective implementation of oscillation damping in practical engineering.This paper introduces the general assumptions of WPGS when analyzing HFO,systematically summarizes the reasons for the occurrence of HFO in different scenarios,deeply analyses the key points and difficulties of HFO damping under different scenarios,and then compares the technical performances of various types of HFO suppression methods to provide adequate references for engineers in the application of technology.Finally,this paper discusses possible future research difficulties in the problem of HFO,as well as the possible future trends in the demand for HFO damping.
文摘In this paper, the Authors present the designing of power system stabilizer (PSS) and static var compensator (SVC) based on chaos, particle swarm optimization (PSO) and shuffled frog leaping (SFL) Algorithms has been presented to improve the power system stability. Single machine infinite bus (SMIB) system with SVC located at the terminal of generator has been considered to evaluate the proposed SVC and PSS controllers. The coefficients of PSS and SVC controller have been optimized by Chaos, PSO and SFL algorithms. Fi-nally the system with proposed controllers is simulated for the special disturbance in input power of genera-tor, and then the dynamic responses of generator have been presented. The simulation results show that the system composed with recommended controller has outstanding operation in fast damping of oscillations of power system and describes an application of Chaos, PSO and SFL algorithms to the problem of designing a Lead-Lag controller used in PSS and SVC in power system.
文摘One method for eliminating oscillations in power systems is using stabilizers.By applying an appropriate control signal in the excitation system of a generator,a power system stabilizer improves the dynamic stability of power systems.However,the issue that is of high importance is the correct design of these stabilizers.These stabilizers must be designed to have proper performance when operating conditions change.When designed incorrectly,not only they do not improve the stability margin,but also increase the oscillations.In this paper,the robust design of power system stabilizers on a four-machine power system has been performed.For this purpose,the differential evolution algorithm has been used.The studies have been repeated as three scenarios by producing different loading conditions for the generators.The performances of the conventional stabilizer and the optimized one have been compared.Simulation results indicate that the designed robust stabilizer outperforms other stabilizers in different conditions and has damped the interarea and intra-area oscillation modes in the shortest time with minimum amplitude.
文摘This research paper deals with the identification of the best location of the Power System Stabilizers (PSS) and also the tuning of PSS parameters in order to improve the overall dynamic stability of multi machine power systems. The location of PSS is determined by identifying the critical modes and their corresponding first and second order eigenvalue sensitivities. In this formulation, sensitivity analysis of a particular mode can be performed with only its eigenvalues and their left and right eigenvectors. The simplicity and efficiency of this approach sharply contrast to the complexity of the traditional approach, where all eigenvalues and eigenvectors are required at the same time. The effectiveness of this method in selecting the optimum location for placement of PSSs is compared with the participation factor method. The proposed sensitivity theory used to identify the best PSS location in a five machine, eight bus El-Metwally and Malik System to increase the damping of both local and inter area modes for various operating conditions.
基金This work is supported by Shanghai Science and Technology Planning Project(Project No.20040501200).
文摘In themarine electric power system,the marine generators will be disturbed by the large change of loads or the fault of the power system.The marine generators usually installed power system stabilizers to damp power system oscillations through the excitation control.This paper proposes a novel method to obtain optimal parameter values for Power System Stabilizer(PSS)to suppress low-frequency oscillations in the marine electric power system.In this paper,a newly developed immune clone selection algorithm was improved from the three aspects of the adaptive incentive degree,vaccination,and adaptive mutation strategies.Firstly,the typical PSS implementation type of leader-lag structure was adopted and the objective function was set in the optimization process.The performance of PSS tuned by improved immune clone selection algorithm was compared with PSS tuned by basic immune clone selection algorithm(ICSA)under various operating conditions and disturbances.Then,an improved immune clone selection algorithm(IICSA)optimization technique was implemented on two test systems for test purposes.Based on the simulations,it is found that an improved immune clone selection algorithm demonstrates superiority over the basic immune clone selection algorithm in getting a smaller number of iterations and fast convergence rates to achieve the optimal parameters of the power system stabilizers.Moreover,the proposed approach improves the stability and dynamic performance under various loads conditions and disturbances of the marine electric power system.
文摘In this paper, we examine the problem of designing power system stabilizer (PSS). A new technique is developed using particle swarm optimization (PSO) combined with linear matrix inequality (LMI). The main feature of PSO, not sticking into a local minimum, is used to eliminate the conservativeness of designing a static output feedback (SOF) stabilizer within an iterative solution of LMIs. The technique is further extended to guarantee robustness against uncertainties wherein power systems operation is changing continuously due to load changes. Numerical simulation ahs illustrated the utility of the developed technique.
文摘This paper presents an analysis of the power flow within the Northern Interconnected Grid of Cameroon. The Newton-Raphson method has been performed, known for its accuracy, under MATLAB software, to model and solve complex power flow equations. This study simulates a series of outage scenarios to evaluate the responsiveness of the grid. The results obtained underline the crucial importance of reactive power management and highlight the urgent need to consolidate the grid infrastructure of North Cameroon. To increase grid resilience and stability, the paper recommends the strategic integration of renewables and the development of interconnections with other power grids. These measures are presented as viable solutions to meet current and future energy distribution challenges, ensuring a reliable and sustainable power supply for Cameroon.
文摘This paper proposes a robust power system stabilizer(PSS)for a steam synchronous generator in Barka II power station.The PSS should be capable of damping small-disturbance oscillations(inherently existing in power systems due to e.g.load changes,lines switching...etc.)within a certain settling time for different load conditions.Also,the proposed PSS must have the conventional structure and its parameters must not be violated.To achieve this goal,robust control provides many advantages.The suggested controller is tuned by the Kharitonov’s theorem and uses the standard structure employed in industry.The problem is cast into a nonlinear constrained optimization problem to achieve the desired settling time without violating the practical values of the controller parameters.Performance of the robust PSS is evaluated by several simulations in the presence of system uncertainty due to load changes.