This paper describes a commonly used pseudo-static method in seismic resistant design of the cross section of underground structures. Based on dynamic theory and the vibration characteristics of underground structures...This paper describes a commonly used pseudo-static method in seismic resistant design of the cross section of underground structures. Based on dynamic theory and the vibration characteristics of underground structures, the sources of errors when using this method are analyzed. The traditional seismic motion loading approach is replaced by a method in which a one-dimensional soil layer response stress is differentiated and then converted into seismic live loads. To validate the improved method, a comparison of analytical results is conducted for internal forces under earthquake shaking of a typical shallow embedded box-shaped subway station structure using four methods: the response displacement method, finite element response acceleration method, the finite element dynamic analysis method and the improved pseudo-static calculation method. It is shown that the improved finite element pseudo-static method proposed in this paper provides an effective tool for the seismic design of underground structures. The evaluation yields results close to those obtained by the finite element dynamic analysis method, and shows that the improved finite element pseudo-static method provides a higher degree of precision.展开更多
Many researchers have developed new calculation methods to analyze seismic slope stability problems, but the conventional pseudo-static method is still widely used in engineering design due to its simplicity. Based on...Many researchers have developed new calculation methods to analyze seismic slope stability problems, but the conventional pseudo-static method is still widely used in engineering design due to its simplicity. Based on the Technical Code for Building Slope Engineering(GB 50330-2013) of China and the Guidelines for Evaluating and Mitigating Seismic Hazards in California(SP117), a comparative study on the pseudo-static method was performed. The results indicate that the largest difference between these two design codes lies in determination of the seismic equivalence reduction factor( f;). The GB 50330-2013 code specifies a single value for f;of 0.25. In SP117, numerous factors,such as magnitude and distance, are considered in determining f;. Two case studies show that the types of slope stability status evaluated by SP117 are in agreement with those evaluated by the seismic time-history stability analysis and Newmark displacement analysis. The factors of safety evaluated by SP117 can be used in practice for safe design. However, the factors of safety evaluated by GB 50330-2013 are risky for slope seismic design.展开更多
基金China Earthquake Administration Association Fund Under Grant No. 106060 and Institute of Engineering Mechanics Director Fund
文摘This paper describes a commonly used pseudo-static method in seismic resistant design of the cross section of underground structures. Based on dynamic theory and the vibration characteristics of underground structures, the sources of errors when using this method are analyzed. The traditional seismic motion loading approach is replaced by a method in which a one-dimensional soil layer response stress is differentiated and then converted into seismic live loads. To validate the improved method, a comparison of analytical results is conducted for internal forces under earthquake shaking of a typical shallow embedded box-shaped subway station structure using four methods: the response displacement method, finite element response acceleration method, the finite element dynamic analysis method and the improved pseudo-static calculation method. It is shown that the improved finite element pseudo-static method proposed in this paper provides an effective tool for the seismic design of underground structures. The evaluation yields results close to those obtained by the finite element dynamic analysis method, and shows that the improved finite element pseudo-static method provides a higher degree of precision.
基金supported by the National Key R&D Program of China(Grant No.2017YFC0404804)the National Natural Science Foundation of China(Grant No.51509019)
文摘Many researchers have developed new calculation methods to analyze seismic slope stability problems, but the conventional pseudo-static method is still widely used in engineering design due to its simplicity. Based on the Technical Code for Building Slope Engineering(GB 50330-2013) of China and the Guidelines for Evaluating and Mitigating Seismic Hazards in California(SP117), a comparative study on the pseudo-static method was performed. The results indicate that the largest difference between these two design codes lies in determination of the seismic equivalence reduction factor( f;). The GB 50330-2013 code specifies a single value for f;of 0.25. In SP117, numerous factors,such as magnitude and distance, are considered in determining f;. Two case studies show that the types of slope stability status evaluated by SP117 are in agreement with those evaluated by the seismic time-history stability analysis and Newmark displacement analysis. The factors of safety evaluated by SP117 can be used in practice for safe design. However, the factors of safety evaluated by GB 50330-2013 are risky for slope seismic design.