The Doppler reflectometer(DR),a powerful diagnostic for the plasma perpendicular velocity(u⊥)and turbulence measurement,has been widely used in various fusion devices.Many efforts have been put into extracting the Do...The Doppler reflectometer(DR),a powerful diagnostic for the plasma perpendicular velocity(u⊥)and turbulence measurement,has been widely used in various fusion devices.Many efforts have been put into extracting the Doppler shift from the DR signal.There are several commonly used methods for Doppler shift extraction,such as the phase derivative,the center of gravity,and symmetric fitting(SFIT).However,the strong zero-order reflection component around 0 kHz may interfere with the calculation of the Doppler shift.To avoid the influence of the zerofrequency peak,the asymmetric fitting(AFIT)method was designed to calculate the Doppler shift.Nevertheless,the AFIT method may lead to an unacceptable error when the Doppler shift is relatively small compared to the half width at half maximum(HWHM).Therefore,an improved method,which can remove the zero-frequency peak and fit the remaining Doppler peak with a Gaussian function,is devised to extract the Doppler shift.This method can still work reliably whether the HWHM is larger than the Doppler shift or not.展开更多
O-mode Doppler reflectometer has been successfully developed as an important diagnostic system on HL-2A. It can be used to measure the turbulence propagation in both plasma edge and confinement zone. The Doppler refle...O-mode Doppler reflectometer has been successfully developed as an important diagnostic system on HL-2A. It can be used to measure the turbulence propagation in both plasma edge and confinement zone. The Doppler reflectometer system consists of two fixed frequency homodyne receivers: 15 GHz (corresponding to cutoff density of 0.3×10^19 m^-3) and 33 GHz (corresponding to cutoff density of 1.35× 10^19 m^-3). The Doppler reflectometry principle and the experimental arrangements on HL-2A are presented. Meanwhile, the experimental Doppler reflectometric spectra under different discharge conditions, with and without ECRH, were obtained. Furthermore, the turbulence propagation velocity change and the profile were also observed in different discharge conditions.展开更多
A phase-sensitive optical time domain reflectometer (φ-OTDR) based on a 120°-phase-difference Michelson in- terferometer is proposed. The Michelson interferometer with arm difference of 4m is used to test the ...A phase-sensitive optical time domain reflectometer (φ-OTDR) based on a 120°-phase-difference Michelson in- terferometer is proposed. The Michelson interferometer with arm difference of 4m is used to test the phase difference between the Rayleigh scattering from two sections of the fiber. A new demodulation method called the inverse transmission matrix demodulation scheme is utilized to demodulate the distributed phase from the backward scattering along the long fiber, The experimental results show that the 120°-phase-difference inter- ferometer φ-OTDR can detect the phase along the 3km fiber, and the acoustic signal within the whole human hearing range of 20 Hz-20 kHz is reproduced accurately and quickly.展开更多
A plasma density profile reconstruction procedure based on the Park matrix method has been developed for both circular and elongated plasma configuration on the Experimental Advanced Superconducting Tokamak(EAST).Th...A plasma density profile reconstruction procedure based on the Park matrix method has been developed for both circular and elongated plasma configuration on the Experimental Advanced Superconducting Tokamak(EAST).This method incorporates the line integrated electron density measured by the HCN interferometer and polarimeter/interferometer(POINT) system,the equilibrium fit(EFIT) based on magnetic measurements and the edge electron density profile provided by the microwave reflectometer.It is shown that when the magnetic flux surfaces are slightly corrected,the fitting error is less than 5% in comparison with the measurement data.展开更多
A novel method for precise measurement of complex reflection coeffcient using a four-port reflectometer is presented. First, three new complex system constants are introduced,which depend only on the scattering parame...A novel method for precise measurement of complex reflection coeffcient using a four-port reflectometer is presented. First, three new complex system constants are introduced,which depend only on the scattering parameters of the four-port reflectometer. Therefore, the stability of the reflectometer is greatly improved. Then, these complex system constants are used to determine the complex reflection coeffcient F of the device under test by calibrating the reflectometer. Finally, a four-port reflectometer comprising a magic tee and a power detector is constructed and excellent experimental results are obtained.展开更多
Comb reflectometers offer the advantage of measuring several radial positions in plasma simultaneously.This allows for the investigation of fast timescales during L-H transitions,I-phases,I-mode bursts,transients duri...Comb reflectometers offer the advantage of measuring several radial positions in plasma simultaneously.This allows for the investigation of fast timescales during L-H transitions,I-phases,I-mode bursts,transients during heat wave propagation,etc.A drawback of many present-day systems is that they use a fixed frequency difference between the probing frequencies.Hence,although the central probing frequency can be varied,the probing frequency difference is usually fixed.The new design presented in this work uses an advanced microwave generation and detection scheme,which allows for arbitrary probing frequencies and probing frequency separations.展开更多
The resonant magnetic perturbation (RMP) coils have been successfully designed and installed on the Experimental Advanced Superconducting Tokamak (EAST). Using the reflectometer systems, the density profile and th...The resonant magnetic perturbation (RMP) coils have been successfully designed and installed on the Experimental Advanced Superconducting Tokamak (EAST). Using the reflectometer systems, the density profile and the density fluctuations during magnetic perturbations (MPs) phase have been investigated. During the experiments, two different cases are studied separately: steady MPs and rotating MPs. In both cases, a strongly density pump-out has been observed. In the steady MPs cases, an enhancement of the low frequency (〈60 kHz) density fluctuations in H-mode phase has been observed. The plasma density boundary out-shifts 5~ caused by the MPs. The pedestal density gradient is reduced by 50%, while the radial location nearly stays unchanged. In the rotating MPs, the line-averaged density, the D~ emission at the divertor region and the spectrum of the density fluctuations are modulated. The results suggest that the low frequency (〈60 kHz) density fluctuations may contribute to the strong density pump-out.展开更多
A broadband frequency tunable microwave reflectometer system, which has the abil- ity of fast and stable frequency sweeping operation, is applied in the large helical device (LHD) to measure the boundary of the high...A broadband frequency tunable microwave reflectometer system, which has the abil- ity of fast and stable frequency sweeping operation, is applied in the large helical device (LHD) to measure the boundary of the high-temperature plasma. When the microwave is launched, with extraordinary polarization, from the low field side of the magnetic field with its frequency swept from low to high, the microwave of minimum right-hand cut-off frequency is reflected most out- side. We can then estimate the plasma boundary position by measuring the change of the reflected power from the cut-off layer.展开更多
Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has bee...Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has been established that facilitates microwave imaging reflectometry and electron cyclotron emission imaging.This platform utilizes plasma profiles as input and incorporates the finite-difference time domain,ray tracing and the radiative transfer equation to calculate the propagation of plasma spontaneous radiation and the external electromagnetic field in plasmas.Benchmark tests for classical cases have been conducted to verify the accuracy of every core module in the GSD platform.Finally,2D imaging of a typical electron temperature distribution is reproduced by this platform and the results are consistent with the given real experimental data.This platform also has the potential to be extended to 3D electromagnetic field simulations and other microwave diagnostics such as cross-polarization scattering.展开更多
The performance of an optical time domain reflectometer(OTDR) is significantly improved using spread spectrum technology. The concept of spread spectrum OTDR(SSOTDR) is proposed, the theoretical basis and simulation r...The performance of an optical time domain reflectometer(OTDR) is significantly improved using spread spectrum technology. The concept of spread spectrum OTDR(SSOTDR) is proposed, the theoretical basis and simulation results of the new method are given, and the problem of direct application of bipolar spread spectrum codes to OTDR and despreading in the optical domain are solved. The simulation results show the feasibility of the SSOTDR, which exhibits better dynamic range reported to date for a practical long-haul OTDR system without using conventional average technique.展开更多
The microwave reflectometer is a popular non-intrusive plasma density diagnostic instrument on tokamaks that provides centimeter and millisecond level resolution.The ultrashort-pulse reflectometer(USPR)achieves plasma...The microwave reflectometer is a popular non-intrusive plasma density diagnostic instrument on tokamaks that provides centimeter and millisecond level resolution.The ultrashort-pulse reflectometer(USPR)achieves plasma density measurement by emitting a chirped wave containing a broadband signal and measuring the time of flight from different frequency components.A USPR system is currently being built on EAST(Experimental Advanced Superconducting Tokamak)to meet the needs of diagnostic of the pedestal density evolution,such as high-frequency small edge-localized modes.In order to predict the density reconstruction of the EAST USPR system,this work presents a numerical simulation study of the beam propagation of the chirped wave of extraordinary waves(X-mode)in the plasma based on Python.The electron density profile has been successfully reconstructed by the reflection signal interpretation.The small gap between the right-hand cut-off layer and the electron cyclotron resonance layer,due to the low plasma density on the plasma edge,causes unexpected leakage from the transmitting microwave beam to the pedestal and the core region.This kind of‘tunneling’effect will cause the reflected signal to have energy loss in the low-frequency band.The study also discusses the influence of the poloidal magnetic field on the reflected signal.The spatial variation of the poloidal magnetic field will lead to the conversion between extraordinary(X)waves and ordinary(O)waves,which leads to energy loss in the reflected signals.The simulation results show that the‘tunneling’effect and the O-X mode conversion effect have little effect on the EAST USPR system.Therefore,the currently designed transmit power meets the working requirements.展开更多
The long-term settlement of calcareous sand foundations caused by daily periodic fluctuations has become a significant geological hazard,but effective monitoring tools to capture the deformation profiles are still rar...The long-term settlement of calcareous sand foundations caused by daily periodic fluctuations has become a significant geological hazard,but effective monitoring tools to capture the deformation profiles are still rarely reported.In this study,a laboratory model test and an in situ monitoring test were conducted.An optical frequency domain reflectometer(OFDR)with high spatial resolution(1 mm)and high accuracy(10-6)was used to record the soil strain responses to groundwater table and varied loads.The results indicated that the fiber-optic measurements can accurately locate the swelling and compressive zones.During the loading process,the interlock between calcareous sand particles was detected,which increased the internal friction angle of soil.The foundation deformation above the sliding surface was dominated by compression,and the soil was continuously compressed beneath the sliding surface.After 26e48 h,calcareous sand swelling occurred gradually above the water table,which was primarily dependent on capillary water.The swelling of the soil beneath the groundwater table was completed rapidly within less than 2 h.When the groundwater table and load remain constant,the compression creep behavior can be described by the Yasong-Wang model with R2¼0.993.The daily periodically varying in situ deformation of calcareous sand primarily occurs between the highest and lowest groundwater tables,i.e.4.2e6.2 m deep.The tuff interlayers with poor water absorption capacity do not swell or compress,but they produce compressive strain under the influence of deformed calcareous sand layers.展开更多
The W7-X stellarator is optimized with respect to neoclassical transport.Therefore turbulent transport plays an important role.It is equipped with an inertial cooled graphite divertor which intersects the island chain...The W7-X stellarator is optimized with respect to neoclassical transport.Therefore turbulent transport plays an important role.It is equipped with an inertial cooled graphite divertor which intersects the island chain at the plasma edge depending on the magnetic configuration.Additional control coils and the plasma current modify the iota profile at the plasma edge and shift the position of the island chain.To monitor the effects on the poloidal propagation velocity in the scrape-off layer(SOL)and the plasma edge,an O-mode Poloidal Correlation Reflectometer(PCR)is used which simultaneously monitors the propagation of low-k turbulence.Operating in the density range of 0.6?×?1019 m-3 to2?×?1019 m-3 it covers a large part of the SOL and the plasma edge and allows for the experimental determination in the last closed flux surface(LCFS)and the associated shear layer in low to middensity discharges.In this paper it is shown that the propagation in the shear layer and its vicinity is determined best,when based on an elliptical model.Different magnetic configurations with magnetic edge topology of five independent islands forι?=?1 and six linked islands forι?=?0.81 are investigated.Also the effects of the plasma current and additional control coils on the edge magnetic topology are studied.The coherence spectra of antenna pairs for different poloidal separations is investigated.Using a decomposition method for the measured coherence spectra the characterization of turbulence spectra is possible with respect to e.g.broad band turbulence and quasi coherent modes.A strong reduction of the broad band turbulence is observed in the vicinity of the LCFS which is evidence for the suppression of low-k turbulence at the shear layer.展开更多
The pavement strength is very important for the evaluation of backlog maintenance. The current trend in many developing countries used pavement conditions index-PCI in estimating maintenance costs. The PCI can only ju...The pavement strength is very important for the evaluation of backlog maintenance. The current trend in many developing countries used pavement conditions index-PCI in estimating maintenance costs. The PCI can only justify periodic and routine recurrent maintenance. The condition strength is rarely determined in a flexible pavement creating an opportunity for back long maintenance. This paper reports the study conducted to develop and improve the algorithm for estimating the adjusted structure number to estimate the remaining thickness of the flexible pavement. The analysis of eight ways of computing structure numbers from FWD data ware analyzed and found that the improvement of the HDM 3 - 4 models can influence the usefulness of data collected from road asset management in Tanzania. The algorithm for estimating structural numbers from CBR was improved to compute adjusted structural numbers finally used to estimate the remaining life of the flexible pavement. The analysis of the network of about 6900 km including ST and AM was found that 64.72% were very good, 12% were Good, 10% were fair and 7.84% were poor and 5.4% were very poor.展开更多
The phase-sensitive time-domain reflectometer [φ-OTDR] has been popularly used for events detection over a long period of time.In this study,the events classification methods based on convolutional neural networks [C...The phase-sensitive time-domain reflectometer [φ-OTDR] has been popularly used for events detection over a long period of time.In this study,the events classification methods based on convolutional neural networks [CNNs] with different features,i.e.,the temporal-spatial features and time-frequency features,are compared and analyzed comprehensively inφ-OTDR.The developed CNNs aim at distinguishing three typical events:wind blowing,knocking,and background noise.The classification accuracy based on temporal-spatial images is higher than that based on time-frequency images[99.49% versus 98.23%).The work here sets a meaningful reference for feature extraction and application in the pattern recognition of φ-OTDR.展开更多
Background:Cataract surgery is the most common surgical procedure in ophthalmology.Biometry data and accurate intraocular lens(IOL)calculations are very important in achieving the desired refractive outcomes.The aim o...Background:Cataract surgery is the most common surgical procedure in ophthalmology.Biometry data and accurate intraocular lens(IOL)calculations are very important in achieving the desired refractive outcomes.The aim of this study was to compare measurements using a new optical low coherence reflectometry(OLCR)biometer(OA-2000)and the gold standard partial coherence interferometry(PCI)optical biometer(IOLMaster 500).Methods:Ocular biometry of cataract patients were measured by the OA-2000 and IOLMaster 500 to compare keratometry(K),axial length(AL),anterior chamber depth(ACD),white-to-white(WTW)diameter,and IOL power using the SRK/T formula.Results:One hundred and two eyes of 68 cataract patients were evaluated with the two optical biometers.The mean values of the AL,K,ACD,and WTW differed very little(OCLR biometer,23.12 mm,44.50 diopters(D),3.06,and 11.64 mm,respectively;PCI biometer,23.18 mm,44.6 D,3.15,and 11.86 mm,respectively),but the differences were significant(all,p≤0.05).The AL,K,and ACD showed excellent correlations(r=0.999,0.980,and 0.824,respectively;all p<0.001);however,there was a weak correlation of the WTW diameter between the two devices(r=0.256).The IOL powers using the SRK-T formula derived from both instruments were very similar,with an excellent correlation(r=0.989).The mean difference between the two instruments was 0.32 D.Conclusions:The OLCR biometer showed very a strong agreement with the standard PCI optical biometer for almost all ocular biometry measurements,except for the WTW diameter.Trial registration:TCTR20160614003;date 06/09/2016;‘retrospectively registered’.展开更多
We have demonstrated a distributed vibration sensor based on phase-sensitive optical time-domain reflectometer (φ-OTDR) system exhibiting immunity to the laser phase noise. Two laser sources with different linewidth ...We have demonstrated a distributed vibration sensor based on phase-sensitive optical time-domain reflectometer (φ-OTDR) system exhibiting immunity to the laser phase noise. Two laser sources with different linewidth and phase noise levels are used in the φ-OTDR system, respectively. Based on the phase noise power spectrum density of both lasers, the laser phase is almost unchanged during an extremely short period of time, hence, the impact of phase noise can be suppressed effectively through phase difference between the Rayleigh scattered light from two adjacent sections of the fiber which define the gauge length. Based on the phase difference method, the external vibration can be located accurately at 41.01 km by the(φ-OTDR system incorporating these two lasers. Meanwhile, the average signal-to-noise ratio (SNR) of the retrieved vibration signal by using Laser I is found to be -37.7 dB, which is comparable to that of -37.5 dB by using Laser II although the linewidth and the phase noise level of the two lasers are distinct. The obtained results indicate that the phase difference method can enhance the performance of(φ-OTDR system with laser phase-noise immunity for distributed vibration sensing, showing potential application in oil-gas pipeline monitoring, perimeter security, and other fields.展开更多
A spatial distribution of diffuse reflectance produced by obliquely incident light is not centered about the point of light entry. The value of shift in the center of diffuse reflectance is directly related to the abs...A spatial distribution of diffuse reflectance produced by obliquely incident light is not centered about the point of light entry. The value of shift in the center of diffuse reflectance is directly related to the absorption coefficient μa and the effective attenuation coefficient μeff. μa and the reduced scattering coefficient μs' of human skin tissues in vivo are measured by oblique-incidence reflectometry based on the two-source diffuse theory model. For ten Chinese volunteers aged 15-63 years, μa and μs' are noninvasively determined to be 0.029 - 0.075 and 0.52 - 0.97 mm^-1, respectively.展开更多
基金supported in part by the National MCF Energy R&D Program(Nos.2018YFE0311200 and 2017YFE0301204)National Natural Science Foundation of China(Nos.U1967206,11975231 and 11922513)supported by the Users with Excellence Program of Hefei Science Center CAS(No.2020HSC-UE009).
文摘The Doppler reflectometer(DR),a powerful diagnostic for the plasma perpendicular velocity(u⊥)and turbulence measurement,has been widely used in various fusion devices.Many efforts have been put into extracting the Doppler shift from the DR signal.There are several commonly used methods for Doppler shift extraction,such as the phase derivative,the center of gravity,and symmetric fitting(SFIT).However,the strong zero-order reflection component around 0 kHz may interfere with the calculation of the Doppler shift.To avoid the influence of the zerofrequency peak,the asymmetric fitting(AFIT)method was designed to calculate the Doppler shift.Nevertheless,the AFIT method may lead to an unacceptable error when the Doppler shift is relatively small compared to the half width at half maximum(HWHM).Therefore,an improved method,which can remove the zero-frequency peak and fit the remaining Doppler peak with a Gaussian function,is devised to extract the Doppler shift.This method can still work reliably whether the HWHM is larger than the Doppler shift or not.
基金National Natural Science Foundation of China(Nos.10335060,10235010)
文摘O-mode Doppler reflectometer has been successfully developed as an important diagnostic system on HL-2A. It can be used to measure the turbulence propagation in both plasma edge and confinement zone. The Doppler reflectometer system consists of two fixed frequency homodyne receivers: 15 GHz (corresponding to cutoff density of 0.3×10^19 m^-3) and 33 GHz (corresponding to cutoff density of 1.35× 10^19 m^-3). The Doppler reflectometry principle and the experimental arrangements on HL-2A are presented. Meanwhile, the experimental Doppler reflectometric spectra under different discharge conditions, with and without ECRH, were obtained. Furthermore, the turbulence propagation velocity change and the profile were also observed in different discharge conditions.
基金Supported by the National Natural Science Foundation of China under Grant Nos U0934001 and 11076028the Science and Technology Commission of Shanghai Municipality under Grant Nos 11DZ1140202 and 13XD1425400the Pudong New Area Science and Technology Development Fund of China under Grant No PKJ2012-D04
文摘A phase-sensitive optical time domain reflectometer (φ-OTDR) based on a 120°-phase-difference Michelson in- terferometer is proposed. The Michelson interferometer with arm difference of 4m is used to test the phase difference between the Rayleigh scattering from two sections of the fiber. A new demodulation method called the inverse transmission matrix demodulation scheme is utilized to demodulate the distributed phase from the backward scattering along the long fiber, The experimental results show that the 120°-phase-difference inter- ferometer φ-OTDR can detect the phase along the 3km fiber, and the acoustic signal within the whole human hearing range of 20 Hz-20 kHz is reproduced accurately and quickly.
基金supported by the National Magnetic Confinement Fusion Science Program of China(Nos.2013GB106003,2014GB106004 and 2014GB106002)National Natural Science Foundation of China(Nos.11475221 and 11105184)
文摘A plasma density profile reconstruction procedure based on the Park matrix method has been developed for both circular and elongated plasma configuration on the Experimental Advanced Superconducting Tokamak(EAST).This method incorporates the line integrated electron density measured by the HCN interferometer and polarimeter/interferometer(POINT) system,the equilibrium fit(EFIT) based on magnetic measurements and the edge electron density profile provided by the microwave reflectometer.It is shown that when the magnetic flux surfaces are slightly corrected,the fitting error is less than 5% in comparison with the measurement data.
文摘A novel method for precise measurement of complex reflection coeffcient using a four-port reflectometer is presented. First, three new complex system constants are introduced,which depend only on the scattering parameters of the four-port reflectometer. Therefore, the stability of the reflectometer is greatly improved. Then, these complex system constants are used to determine the complex reflection coeffcient F of the device under test by calibrating the reflectometer. Finally, a four-port reflectometer comprising a magic tee and a power detector is constructed and excellent experimental results are obtained.
基金funding from the Euratom research and training programme 2014-2018 and2019-2020 under grant agreement No.633053。
文摘Comb reflectometers offer the advantage of measuring several radial positions in plasma simultaneously.This allows for the investigation of fast timescales during L-H transitions,I-phases,I-mode bursts,transients during heat wave propagation,etc.A drawback of many present-day systems is that they use a fixed frequency difference between the probing frequencies.Hence,although the central probing frequency can be varied,the probing frequency difference is usually fixed.The new design presented in this work uses an advanced microwave generation and detection scheme,which allows for arbitrary probing frequencies and probing frequency separations.
基金supported by the National Magnetic Confinement Fusion Science Program of China(Nos.2014GB106000,2014GB106003 and2015GB110001)National Natural Science Foundation of China(Nos.11275234,11305215,11305208,11405214 and 11505221)
文摘The resonant magnetic perturbation (RMP) coils have been successfully designed and installed on the Experimental Advanced Superconducting Tokamak (EAST). Using the reflectometer systems, the density profile and the density fluctuations during magnetic perturbations (MPs) phase have been investigated. During the experiments, two different cases are studied separately: steady MPs and rotating MPs. In both cases, a strongly density pump-out has been observed. In the steady MPs cases, an enhancement of the low frequency (〈60 kHz) density fluctuations in H-mode phase has been observed. The plasma density boundary out-shifts 5~ caused by the MPs. The pedestal density gradient is reduced by 50%, while the radial location nearly stays unchanged. In the rotating MPs, the line-averaged density, the D~ emission at the divertor region and the spectrum of the density fluctuations are modulated. The results suggest that the low frequency (〈60 kHz) density fluctuations may contribute to the strong density pump-out.
基金a Grant-in-Aid for Scientific Research on Priority Areas (Nos.18035015,20026010)a Grant-in-Aid for Young Scientists (A)(No.18686075)the Ministry of Education,Culture,Sports,Science and Technology Japan and also a budgetary Grant-in-Aid (No.NIFS08ULHH508)of National Institute for Fusion Science and the JSPS-CAS Core-University Program in the field of Plasma and Nuclear Fusion
文摘A broadband frequency tunable microwave reflectometer system, which has the abil- ity of fast and stable frequency sweeping operation, is applied in the large helical device (LHD) to measure the boundary of the high-temperature plasma. When the microwave is launched, with extraordinary polarization, from the low field side of the magnetic field with its frequency swept from low to high, the microwave of minimum right-hand cut-off frequency is reflected most out- side. We can then estimate the plasma boundary position by measuring the change of the reflected power from the cut-off layer.
基金supported by the National Magnetic Confinement Fusion Energy Program of China(No.2019YFE03020001)the Collaborative Innovation Program of Hefei Science Center,CAS(No.2021HSC-CIP010)the Fundamental Research Funds for the Central Universities。
文摘Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has been established that facilitates microwave imaging reflectometry and electron cyclotron emission imaging.This platform utilizes plasma profiles as input and incorporates the finite-difference time domain,ray tracing and the radiative transfer equation to calculate the propagation of plasma spontaneous radiation and the external electromagnetic field in plasmas.Benchmark tests for classical cases have been conducted to verify the accuracy of every core module in the GSD platform.Finally,2D imaging of a typical electron temperature distribution is reproduced by this platform and the results are consistent with the given real experimental data.This platform also has the potential to be extended to 3D electromagnetic field simulations and other microwave diagnostics such as cross-polarization scattering.
基金supported by the National Natural Science Foundation of China (No.61735011)the Science and Technology Research Project of Hebei University (No.QN2017141)the Key Research and Development Program of Hebei Province (No.19251703D)。
文摘The performance of an optical time domain reflectometer(OTDR) is significantly improved using spread spectrum technology. The concept of spread spectrum OTDR(SSOTDR) is proposed, the theoretical basis and simulation results of the new method are given, and the problem of direct application of bipolar spread spectrum codes to OTDR and despreading in the optical domain are solved. The simulation results show the feasibility of the SSOTDR, which exhibits better dynamic range reported to date for a practical long-haul OTDR system without using conventional average technique.
基金supported by the National Magnetic Confinement Fusion Energy R&D Program of China(No.2019YFE03030004)National Natural Science Foundation of China(No.12005144)。
文摘The microwave reflectometer is a popular non-intrusive plasma density diagnostic instrument on tokamaks that provides centimeter and millisecond level resolution.The ultrashort-pulse reflectometer(USPR)achieves plasma density measurement by emitting a chirped wave containing a broadband signal and measuring the time of flight from different frequency components.A USPR system is currently being built on EAST(Experimental Advanced Superconducting Tokamak)to meet the needs of diagnostic of the pedestal density evolution,such as high-frequency small edge-localized modes.In order to predict the density reconstruction of the EAST USPR system,this work presents a numerical simulation study of the beam propagation of the chirped wave of extraordinary waves(X-mode)in the plasma based on Python.The electron density profile has been successfully reconstructed by the reflection signal interpretation.The small gap between the right-hand cut-off layer and the electron cyclotron resonance layer,due to the low plasma density on the plasma edge,causes unexpected leakage from the transmitting microwave beam to the pedestal and the core region.This kind of‘tunneling’effect will cause the reflected signal to have energy loss in the low-frequency band.The study also discusses the influence of the poloidal magnetic field on the reflected signal.The spatial variation of the poloidal magnetic field will lead to the conversion between extraordinary(X)waves and ordinary(O)waves,which leads to energy loss in the reflected signals.The simulation results show that the‘tunneling’effect and the O-X mode conversion effect have little effect on the EAST USPR system.Therefore,the currently designed transmit power meets the working requirements.
基金support provided by the National Natural Science Foundation of China(Grant No.41907244)China Postdoctoral Science Foundation(Grant No.2019M653180)the Project of the Key Laboratory of Soft Soil and Environmental Geotechnical Ministry of Education(Grant No.2019P05)is gratefully acknowledged.
文摘The long-term settlement of calcareous sand foundations caused by daily periodic fluctuations has become a significant geological hazard,but effective monitoring tools to capture the deformation profiles are still rarely reported.In this study,a laboratory model test and an in situ monitoring test were conducted.An optical frequency domain reflectometer(OFDR)with high spatial resolution(1 mm)and high accuracy(10-6)was used to record the soil strain responses to groundwater table and varied loads.The results indicated that the fiber-optic measurements can accurately locate the swelling and compressive zones.During the loading process,the interlock between calcareous sand particles was detected,which increased the internal friction angle of soil.The foundation deformation above the sliding surface was dominated by compression,and the soil was continuously compressed beneath the sliding surface.After 26e48 h,calcareous sand swelling occurred gradually above the water table,which was primarily dependent on capillary water.The swelling of the soil beneath the groundwater table was completed rapidly within less than 2 h.When the groundwater table and load remain constant,the compression creep behavior can be described by the Yasong-Wang model with R2¼0.993.The daily periodically varying in situ deformation of calcareous sand primarily occurs between the highest and lowest groundwater tables,i.e.4.2e6.2 m deep.The tuff interlayers with poor water absorption capacity do not swell or compress,but they produce compressive strain under the influence of deformed calcareous sand layers.
基金funding from the Euratom research and training program 2014-2018 and2019-2020 under grant agreement no.633053。
文摘The W7-X stellarator is optimized with respect to neoclassical transport.Therefore turbulent transport plays an important role.It is equipped with an inertial cooled graphite divertor which intersects the island chain at the plasma edge depending on the magnetic configuration.Additional control coils and the plasma current modify the iota profile at the plasma edge and shift the position of the island chain.To monitor the effects on the poloidal propagation velocity in the scrape-off layer(SOL)and the plasma edge,an O-mode Poloidal Correlation Reflectometer(PCR)is used which simultaneously monitors the propagation of low-k turbulence.Operating in the density range of 0.6?×?1019 m-3 to2?×?1019 m-3 it covers a large part of the SOL and the plasma edge and allows for the experimental determination in the last closed flux surface(LCFS)and the associated shear layer in low to middensity discharges.In this paper it is shown that the propagation in the shear layer and its vicinity is determined best,when based on an elliptical model.Different magnetic configurations with magnetic edge topology of five independent islands forι?=?1 and six linked islands forι?=?0.81 are investigated.Also the effects of the plasma current and additional control coils on the edge magnetic topology are studied.The coherence spectra of antenna pairs for different poloidal separations is investigated.Using a decomposition method for the measured coherence spectra the characterization of turbulence spectra is possible with respect to e.g.broad band turbulence and quasi coherent modes.A strong reduction of the broad band turbulence is observed in the vicinity of the LCFS which is evidence for the suppression of low-k turbulence at the shear layer.
文摘The pavement strength is very important for the evaluation of backlog maintenance. The current trend in many developing countries used pavement conditions index-PCI in estimating maintenance costs. The PCI can only justify periodic and routine recurrent maintenance. The condition strength is rarely determined in a flexible pavement creating an opportunity for back long maintenance. This paper reports the study conducted to develop and improve the algorithm for estimating the adjusted structure number to estimate the remaining thickness of the flexible pavement. The analysis of eight ways of computing structure numbers from FWD data ware analyzed and found that the improvement of the HDM 3 - 4 models can influence the usefulness of data collected from road asset management in Tanzania. The algorithm for estimating structural numbers from CBR was improved to compute adjusted structural numbers finally used to estimate the remaining life of the flexible pavement. The analysis of the network of about 6900 km including ST and AM was found that 64.72% were very good, 12% were Good, 10% were fair and 7.84% were poor and 5.4% were very poor.
基金supported by the Fundamental Research Funds for the Central Universities(No.FRF-TP-20-067A1Z)。
文摘The phase-sensitive time-domain reflectometer [φ-OTDR] has been popularly used for events detection over a long period of time.In this study,the events classification methods based on convolutional neural networks [CNNs] with different features,i.e.,the temporal-spatial features and time-frequency features,are compared and analyzed comprehensively inφ-OTDR.The developed CNNs aim at distinguishing three typical events:wind blowing,knocking,and background noise.The classification accuracy based on temporal-spatial images is higher than that based on time-frequency images[99.49% versus 98.23%).The work here sets a meaningful reference for feature extraction and application in the pattern recognition of φ-OTDR.
文摘Background:Cataract surgery is the most common surgical procedure in ophthalmology.Biometry data and accurate intraocular lens(IOL)calculations are very important in achieving the desired refractive outcomes.The aim of this study was to compare measurements using a new optical low coherence reflectometry(OLCR)biometer(OA-2000)and the gold standard partial coherence interferometry(PCI)optical biometer(IOLMaster 500).Methods:Ocular biometry of cataract patients were measured by the OA-2000 and IOLMaster 500 to compare keratometry(K),axial length(AL),anterior chamber depth(ACD),white-to-white(WTW)diameter,and IOL power using the SRK/T formula.Results:One hundred and two eyes of 68 cataract patients were evaluated with the two optical biometers.The mean values of the AL,K,ACD,and WTW differed very little(OCLR biometer,23.12 mm,44.50 diopters(D),3.06,and 11.64 mm,respectively;PCI biometer,23.18 mm,44.6 D,3.15,and 11.86 mm,respectively),but the differences were significant(all,p≤0.05).The AL,K,and ACD showed excellent correlations(r=0.999,0.980,and 0.824,respectively;all p<0.001);however,there was a weak correlation of the WTW diameter between the two devices(r=0.256).The IOL powers using the SRK-T formula derived from both instruments were very similar,with an excellent correlation(r=0.989).The mean difference between the two instruments was 0.32 D.Conclusions:The OLCR biometer showed very a strong agreement with the standard PCI optical biometer for almost all ocular biometry measurements,except for the WTW diameter.Trial registration:TCTR20160614003;date 06/09/2016;‘retrospectively registered’.
文摘We have demonstrated a distributed vibration sensor based on phase-sensitive optical time-domain reflectometer (φ-OTDR) system exhibiting immunity to the laser phase noise. Two laser sources with different linewidth and phase noise levels are used in the φ-OTDR system, respectively. Based on the phase noise power spectrum density of both lasers, the laser phase is almost unchanged during an extremely short period of time, hence, the impact of phase noise can be suppressed effectively through phase difference between the Rayleigh scattered light from two adjacent sections of the fiber which define the gauge length. Based on the phase difference method, the external vibration can be located accurately at 41.01 km by the(φ-OTDR system incorporating these two lasers. Meanwhile, the average signal-to-noise ratio (SNR) of the retrieved vibration signal by using Laser I is found to be -37.7 dB, which is comparable to that of -37.5 dB by using Laser II although the linewidth and the phase noise level of the two lasers are distinct. The obtained results indicate that the phase difference method can enhance the performance of(φ-OTDR system with laser phase-noise immunity for distributed vibration sensing, showing potential application in oil-gas pipeline monitoring, perimeter security, and other fields.
基金supported by the National Natural Science Foundation of China under Grant No.60577011
文摘A spatial distribution of diffuse reflectance produced by obliquely incident light is not centered about the point of light entry. The value of shift in the center of diffuse reflectance is directly related to the absorption coefficient μa and the effective attenuation coefficient μeff. μa and the reduced scattering coefficient μs' of human skin tissues in vivo are measured by oblique-incidence reflectometry based on the two-source diffuse theory model. For ten Chinese volunteers aged 15-63 years, μa and μs' are noninvasively determined to be 0.029 - 0.075 and 0.52 - 0.97 mm^-1, respectively.