An approximate analytic model is presented to describe spatial structure of refracted electromagnetic field arising at oblique incidence of a Gaussian beam on a plane boundary of an absorbing homogeneous medium. The a...An approximate analytic model is presented to describe spatial structure of refracted electromagnetic field arising at oblique incidence of a Gaussian beam on a plane boundary of an absorbing homogeneous medium. The analytic solution is obtained by asymptotic approximation of a Fourier field integral under the condition of great beam width in comparison with a wavelength (the geometrical-optics approximation). This model can be used also for approximate simulation of refracted field in the cases of beam incidence near the critical angle on transparent or absorbing (amplifying) refracting medium, if one artificially introduces the additional absorption (amplification), whose value is proportional to the ratio of the wavelength and the effective beam width. It is shown that the analytic model reflects the general features of refracted field at total internal reflection.展开更多
AIM:To present the 1-year results of a prospective cohort study investigating the efficacy,potential mechanism,and safety of orthokeratology(ortho-k)with different back optic zone diameters(BOZD)for myopia control in ...AIM:To present the 1-year results of a prospective cohort study investigating the efficacy,potential mechanism,and safety of orthokeratology(ortho-k)with different back optic zone diameters(BOZD)for myopia control in children.METHODS:This randomized clinical study was performed between Dec.2020 and Dec.2021.Participants were randomly assigned to three groups wearing ortho-k:5 mm BOZD(5-MM group),5.5 mm BOZD(5.5-MM group),and 6 mm BOZD(6-MM group).The 1-year data were recorded,including axial length,relative peripheral refraction(RPR,measured by multispectral refractive topography,MRT),and visual quality.The contrast sensitivity(CS)was evaluated by CSV-1000 instrument with spatial frequencies of 3,6,12,and 18 cycles/degree(c/d);the corneal higher-order aberrations(HOAs)were measured by iTrace aberration analyzer.The one-way ANOVA was performed to assess the differences between the three groups.The correlation between the change in AL and RPR was calculated by Pearson’s correlation coefficient.RESULTS:The 1-year results of 20,21,and 21 subjects in the 5-MM,5.5-MM,and 6-MM groups,respectively,were presented.There were no statistical differences in baseline age,sex,or ocular parameters between the three groups(all P>0.05).At the 1-year visit,the 5-MM group had lower axial elongation than the 6-MM group(0.07±0.09 vs 0.18±0.11 mm,P=0.001).The 5-MM group had more myopic total RPR(TRPR,P=0.014),with RPR in the 15°–30°(RPR 15–30,P=0.015),30°–45°(RPR 30–45,P=0.011),temporal(RPR-T,P=0.008),and nasal area(RPR-N,P<0.001)than the 6-MM group.RPR 15–30 in the 5.5-MM group was more myopic than that in the 6-MM group(P=0.002),and RPR-N in the 5-MM group was more myopic than that in the 5.5-MM group(P<0.001).There were positive correlations between the axial elongation and the change in TRPR(r=0.756,P<0.001),RPR 15–30(r=0.364,P=0.004),RPR 30–45(r=0.306,P=0.016),and RPR-N(r=0.253,P=0.047).The CS decreased at 3 c/d(P<0.001),and the corneal HOAs increased in the 5-MM group(P=0.030).CONCLUSION:Ortho-k with 5 mm BOZD can control myopia progression more effectively.The mechanism may be associated with greater myopic shifts in RPR.展开更多
AIM:To investigate the prevalence of visual impairment(VI)and provide an estimation of uncorrected refractive errors in school-aged children,conducted by optometry students as a community service.METHODS:The study was...AIM:To investigate the prevalence of visual impairment(VI)and provide an estimation of uncorrected refractive errors in school-aged children,conducted by optometry students as a community service.METHODS:The study was cross-sectional.Totally 3343 participants were included in the study.The initial examination involved assessing the uncorrected distance visual acuity(UDVA)and visual acuity(VA)while using a+2.00 D lens.The inclusion criteria for a subsequent comprehensive cycloplegic eye examination,performed by an optometrist,were as follows:a UDVA<0.6 decimal(0.20 logMAR)and/or a VA with+2.00 D≥0.8 decimal(0.96 logMAR).RESULTS:The sample had a mean age of 10.92±2.13y(range 4 to 17y),and 51.3%of the children were female(n=1715).The majority of the children(89.7%)fell within the age range of 8 to 14y.Among the ethnic groups,the highest representation was from the Luhya group(60.6%)followed by Luo(20.4%).Mean logMAR UDVA choosing the best eye for each student was 0.29±0.17(range 1.70 to 0.22).Out of the total,246 participants(7.4%)had a full eye examination.The estimated prevalence of myopia(defined as spherical equivalent≤-0.5 D)was found to be 1.45%of the total sample.While around 0.18%of the total sample had hyperopia value exceeding+1.75 D.Refractive astigmatism(cil<-0.75 D)was found in 0.21%(7/3343)of the children.The VI prevalence was 1.26%of the total sample.Among our cases of VI,76.2%could be attributed to uncorrected refractive error.Amblyopia was detected in 0.66%(22/3343)of the screened children.There was no statistically significant correlation observed between age or gender and refractive values.CONCLUSION:The primary cause of VI is determined to be uncorrected refractive errors,with myopia being the most prevalent refractive error observed.These findings underscore the significance of early identification and correction of refractive errors in school-aged children as a means to alleviate the impact of VI.展开更多
Three-component seismic exploration through P-wave source and three-component geophone is an effective technique used in complicated reservoir exploration. In three-component seismic exploration data processing,one of...Three-component seismic exploration through P-wave source and three-component geophone is an effective technique used in complicated reservoir exploration. In three-component seismic exploration data processing,one of the difficulties is static correction of converted wave. This paper analyzes propagation characteristics of non-converted and converted refracted waves,and discovers a favor-able condition for the formation of converted refracted wave,i.e. the velocity of overlaying medium S wave is much lower than that of underlying medium S wave. In addition,the paper proposes the static correction method of converted wave based on PPS converted refracted wave,and processes the real three-component seismic data with better results of static correction of converted wave.展开更多
AIM:To describe the distribution of refractive errors by age and sex among schoolchildren in Soacha,Colombia.METHODS:This was an observational cross-sectional study conducted in five urban public schools in the munici...AIM:To describe the distribution of refractive errors by age and sex among schoolchildren in Soacha,Colombia.METHODS:This was an observational cross-sectional study conducted in five urban public schools in the municipality of Soacha.A total of 1161 school-aged and pre-adolescent children,aged 5-12y were examined during the school year 2021-2022.Examinations included visual acuity and static refraction.Spherical equivalent(SE)was analysed as follows:myopia SE≤-0.50 D and uncorrected visual acuity of 20/25 or worse;high myopia SE≤-6.00 D;hyperopia SE≥+1.00 D(≥7y)or SE≥+2.00 D(5-6y);significant hyperopia SE≥+3.00 D.Astigmatism was defined as a cylinder in at least one eye≥1.00 D(≥7y)or≥1.75 D(5-6y).If at least one eye was ametropic,children were classified according to the refractive error found.RESULTS:Of the 1139 schoolchildren included,50.6%were male,58.8%were aged between 5 and 9y,and 12.1%were already using optical correction.The most common refractive error was astigmatism(31.1%),followed by myopia(20.8%)and hyperopia(13.1%).There was no significant relationship between refractive error and sex.There was a significant increase in astigmatism(P<0.001)and myopia(P<0.0001)with age.CONCLUSION:Astigmatism is the most common refractive error in children in an urban area of Colombia.Emmetropia decreased and myopia increased with age.展开更多
AIM:To compare relative peripheral refraction(RPR)in Chinese school children with different refractive errors using multispectral refraction topography(MRT).METHODS:A total of 713 eyes of primary school children[172 e...AIM:To compare relative peripheral refraction(RPR)in Chinese school children with different refractive errors using multispectral refraction topography(MRT).METHODS:A total of 713 eyes of primary school children[172 emmetropia(E),429 low myopia(LM),80 moderate myopia(MM),and 32 low hypermetropia(LH)]aged 10 to 13y were analyzed.RPRs were measured using MRT without mydriasis.MRT results showed RPR at 0-15°(RPR 0-15),15°-30°(RPR 15-30),and 30°-45°(RPR 30-45)annular in the inferior(RPR-I),superior(RPR-S),nasal(RPR-N),and temporal(RPR-T)quadrants.Spherical equivalent(SE)was detected and calculated using an autorefractor.RESULTS:There were significant differences of RPR 15-30 between groups MM[0.02(-0.12;0.18)]and LH[-0.13(-0.36;0.12)](P<0.05),MM and E[-0.06(-0.20;0.10)](P<0.05),and LM[-0.02(-0.15;0.15)]and E(P<0.05).There were also significant differences of RPR 30-45 between groups MM[0.45(0.18;0.74)]and E[0.29(-0.09;0.67)](P<0.05),and LM[0.44(0.14;0.76)]and E(P<0.001).RPR values increased from the hyperopic to medium myopic group in each annular.There were significant differences of RPR-S between groups MM[-0.02(-0.60;0.30)]and E[-0.44(-0.89;-0.04)](P<0.001),and LM[-0.28(-0.71;0.12)]and E(P<0.05).There were also significant differences of RPR-T between groups MM[0.37(0.21;0.78)]and LH[0.14(-0.52;0.50)](P<0.05),LM[0.41(0.06;0.84)]and LH(P<0.05),and LM and E[0.29(-0.10;0.68),P<0.05].A Spearman’s correlation analysis showed a negative correlation between RPR and SE in the 15°-30°(P=0.005),30°-45°(P<0.05)annular(P=0.002),superior(P<0.001),and temporal(P=0.001)quadrants.CONCLUSION:Without pupil dilation,values for RPR 15-30,30-45,RPR-S,and T shows significant differences between myopic eyes and emmetropia,and the differences are negatively correlated with SE.展开更多
AIM:To evaluate the refraction difference value(RDV)variations in children and adolescents with different refractive errors and analyze its correlation with refractive development.METHODS:Participants aged 4-16y with ...AIM:To evaluate the refraction difference value(RDV)variations in children and adolescents with different refractive errors and analyze its correlation with refractive development.METHODS:Participants aged 4-16y with different refractive statuses(hyperopia,emmetropia,myopia)underwent comprehensive eye examinations,including spherical equivalent(SE)refraction,axial length(AL),total RDV(TRDV),and RDVs at various eccentricities(0°-15°,15°-30°,30°-45°)and quadrants(inferior,superior,nasal,temporal).Statistical analysis involved one-way ANOVA for group comparisons and Pearson correlation for examining relationships between SE/AL and RDVs.Paired t-tests compared quadrant-specific RDVs within groups.RESULTS:Significant difference was found in TRDV(P<0.001),RDV15°-30°(P=0.033),RDV30°-45°(P<0.001),RDV-inferior(RDV-I,P<0.001)and RDV-temporal(RDV-T,P<0.001)among hyperopia,emmetropia and myopia group.Pearson correlation analysis revealed a negative correlation of SE with TRDV(P=0.001),RDV30°-45°(P=0.004),RDV-I(P=0.047),and RDV-T(P<0.001).The differences between RDV-superior(RDV-S)and RDV-I were statistically significant in all groups(P<0.001 for all)and between RDV-T and RDV-nasal(RDV-N)were statistically significant in hyperopia group(P<0.001).Within the premyopic group,the analysis revealed a negative correlation of SE with RDV-I(P=0.009).Pearson correlation analysis revealed a positive correlation of AL with TRDV(P=0.036),RDV15°-30°(P=0.004),RDV30°-45°(P<0.001),RDV-S(P=0.003),RDV-I(P<0.001),RDV-T(P<0.001),RDV-N(P=0.022),while revealed a negative correlation of AL with RDV0-15°(P=0.018).CONCLUSION:Our study indicates TRDV,RDV30°-45°,RDV-I,RDV-T may relate to refractive development,and a negative correlation between SE and RDV-I in pre-myopic children.展开更多
Elastic metamaterials with unusual elastic properties offer unprecedented ways to modulate the polarization and propagation of elastic waves.However,most of them rely on the resonant structural components,and thus are...Elastic metamaterials with unusual elastic properties offer unprecedented ways to modulate the polarization and propagation of elastic waves.However,most of them rely on the resonant structural components,and thus are frequency-dependent and unchangeable.Here,we present a reconfigurable 2D mechanism-based metamaterial which possesses transformable and frequency-independent elastic properties.Based on the proposed mechanism-based metamaterial,interesting functionalities,such as ternarycoded elastic wave polarizer and programmable refraction,are demonstrated.Particularly,unique ternary-coded polarizers,with 1-trit polarization filtering and 2-trit polarization separating of longitudinal and transverse waves,are first achieved.Then,the strong anisotropy of the proposed metamaterial is harnessed to realize positive-negative bi-refraction,only-positive refraction,and only-negative refraction.Finally,the wave functions with detailed microstructures are numerically verified.展开更多
Transparent photoresists with a high refractive index(RI)and high transmittance in visible wavelengths have promising functionalities in optical fields.This work reports a kind of tunable optical material composed of ...Transparent photoresists with a high refractive index(RI)and high transmittance in visible wavelengths have promising functionalities in optical fields.This work reports a kind of tunable optical material composed of titanium dioxide nanoparticles embedded in acrylic resin with a high RI for ultraviolet(UV)-imprint lithography.The hybrid film exhibits a tunable RI of up to 1.67(589 nm)after being cured by UV light,while maintaining both a high transparency of over 98%in the visible light range and a low haze of less than 0.05%.The precision machining of optical microstructures can be imprinted easily and efficiently using the hybrid resin,which acts as a light guide plate(LGP)to guide the light from the side to the top in order to conserve the energy of the display device.These preliminary studies based on both laboratory and commercial experiments pave the way for exploiting the unparalleled optical properties of nanocomposite resins and promoting their industrial application.展开更多
Acoustic emission(AE)localization algorithms based on homogeneous media or single-velocity are less accurate when applied to the triaxial localization experiments.To the end,a robust triaxial localization method of AE...Acoustic emission(AE)localization algorithms based on homogeneous media or single-velocity are less accurate when applied to the triaxial localization experiments.To the end,a robust triaxial localization method of AE source using refraction path is proposed.Firstly,the control equation of the refraction path is established according to the sensor coordinates and arrival times.Secondly,considering the influence of time-difference-of-arrival(TDOA)errors,the residual of the governing equation is calculated to estimate the equation weight.Thirdly,the refraction points in different directions are solved using Snell’s law and orthogonal constraints.Finally,the source coordinates are iteratively solved by weighted correction terms.The feasibility and accuracy of the proposed method are verified by pencil-lead breaking experiments.The simulation results show that the new method is almost unaffected by the refraction ratio,and always holds more stable and accurate positioning performance than the traditional method under different ratios and scales of TDOA outliers.展开更多
Metal-based surface plasmon resonance(SPR)plays an important role in enhancing the photonic spin Hall effect(SHE)and developing sensitive optical sensors.However,the very large negative permittivities of metals limit ...Metal-based surface plasmon resonance(SPR)plays an important role in enhancing the photonic spin Hall effect(SHE)and developing sensitive optical sensors.However,the very large negative permittivities of metals limit their applications beyond the near-infrared regime.In this work,we theoretically present a new mechanism to enhance the photonic SHE by taking advantage of SiC-supported surface phonon resonance(SPhR)in the mid-infrared regime.The transverse displacement of photonic SHE is very sensitive to the wavelength of incident light and the thickness of SiC layer.Under the optimal parameter setup,the calculated largest transverse displacement of SiC-based SPhR structure reaches up to 163.8 ym,which is much larger than the condition of SPR.Moreover,an NO_(2) gas sensor based on the SPhR-enhanced photonic SHE is theoretically proposed with the superior sensing performance.Both the intensity and angle sensitivity of this sensor can be effectively manipulated by varying the damping rate of SiC.The results may provide a promising paradigm to enhance the photonic SHE in the mid-infrared region and open up new opportunity of highly sensitive refractive index sensors.展开更多
AIM:To describe the distribution of ocular biometrics and to evaluate its associations with refractive error and to assess the contribution from ocular parameters to refractive error among Chinese myopic children.METH...AIM:To describe the distribution of ocular biometrics and to evaluate its associations with refractive error and to assess the contribution from ocular parameters to refractive error among Chinese myopic children.METHODS:This cross-sectional study evaluated subjects aged 8-12y.Keratometry,ocular biometry,and cycloplegic autorefraction were performed on each subject.Spherical equivalent refraction(SER)and ocular biometrics were assessed as a function of age and gender.The Pearson correlation analysis between SER and ocular biometrics was carried out.Multiple linear regression was performed to analyze the association between SER and ocular parameters.RESULTS:A total of 689 out of 735 participants(321 boys,48.1%)were analyzed,with a mean SER of-2.98±1.47 diopter(D).Axial length(AL),anterior chamber depth(ACD),corneal radius of curvature(CR),horizontal visible iris diameter(HVID),central corneal thickness(CCT)and lens power(LP)showed normal distribution.The AL,AL/CR ratio,ACD and CR increased from 8 to 12y of age,while SER and LP decreased,HVID and CCT remained stable.There was no difference in gender.SER decreased by 0.929 D for every 1 mm increase in AL and decreased by 1.144 D for every 0.1 increase in AL/CR ratio.The Pearson correlation coefficient between SER and AL was-0.538(P<0.01)and-0.747(P<0.01)between SER and AL/CR ratio.For the SER variance,AL explained 29.0%,AL/CR ratio explained 55.7%,while AL,CR,ACD and LP explained 99.3%after adjusting for age and gender.CONCLUSION:The AL,CR,ACD and LP are the most important determinants of myopic refractive error during myopia progression.展开更多
AIM:To evaluate the clinical outcomes after subsequent implantation of a new intrastromal corneal ring segment(ICRS)model followed by an additional short-arc ICRS implant in keratoconus patients.METHODS:This retrospec...AIM:To evaluate the clinical outcomes after subsequent implantation of a new intrastromal corneal ring segment(ICRS)model followed by an additional short-arc ICRS implant in keratoconus patients.METHODS:This retrospective single-arm cohort study evaluated 25 eyes of 21 keratoconus patients implanted with the new ICRS followed by 140-arch length ICRS(140-ICRS)implantation.Uncorrected distance visual acuity(UDVA,logMAR),corrected distance visual acuity(CDVA,logMAR),sphere,astigmatism,keratometry,spherical equivalent(SE),and asphericity were compared preoperatively and postoperatively after both ICRS implantation.RESULTS:The average follow-up time after 140-ICRS implantation was 6.40±2.20mo.The mean preoperative UDVA improved from 1.27±0.14 preoperative to 0.52±0.26 after both ICRS implantation(P=0.03).The mean sphere value reduced from-5.34±2.74 preoperatively to-2.06±1.84 postoperatively(P<0.001)after the first ICRS implantation and decreased to-0.59±1.54 postoperatively(P<0.001)after 140-ICRS implantation.The mean preoperative astigmatism was-3.72±1.56 and improved to-2.82±1.08 after the first ICRS implantation,and following the 140-ICRS implantation,the mean astigmatism was-1.37±0.67(P=0.001).The SE and asphericity changes were statistically significant(P<0.001).The researchers did not find intraoperative or postoperative complications for both procedures.CONCLUSION:The combination of 2 different ICRSs can efficiently regularize the cornea,reduce the SE,and improve visual acuity in selected keratoconus patients.展开更多
AIM:To compare relative peripheral refractive errors(RPREs)in Chinese children with and without myopic anisometropia(MAI)and to explore the relationship between RPRE and myopia.METHODS:This observational cross-section...AIM:To compare relative peripheral refractive errors(RPREs)in Chinese children with and without myopic anisometropia(MAI)and to explore the relationship between RPRE and myopia.METHODS:This observational cross-sectional study included 160 children divided into two groups according to the interocular spherical equivalent refraction(SER)difference≥1.0 D in the MAI group(n=80)and<1.0 D in the non-MAI group(n=80).The MAI group was further divided into two subgroups:ΔSER<2.0 D group and ΔSER≥2.0 D group.Basic ocular biometric parameters of axial length(AL),average keratometry(Ave K),cylinder(CYL),surface regularity index(SRI),and surface asymmetry index(SAI)were recorded.In addition,multispectral refraction topography was performed to measure RPRE,and the parameters were recorded as total refraction difference value(TRDV),refraction difference value(RDV)0-10,RDV10-20,RDV20-30,RDV30-40,RDV40-53,RDV-superior(RDV-S),RDV-inferior(RDV-I),RDV-temporal(RDV-T)and RDV-nasal(RDV-N).RESULTS:In the non-MAI group,the interocular differences of all parameters of RPRE were not significant.In the MAI group,the interocular differences of TRDV,RDV10-53,RDV-S,RDV-I,RDV-T,and RDV-N were significant.In subgroup analysis,the interocular differences of TRDV,RDV30-53,RDV-I,and RDV-T were significant in ΔSER<2.0 D group and ΔSER≥2.0 D group,but the interocular differences of RDV10-30,RDV-S and RDV-N were only significant in the ΔSER≥2.0 D group.In correlation analysis,ΔTRDV,ΔRDV 10-53,ΔRDV-S,and ΔRDV-N were negatively correlated with ΔSER but positively correlated with ΔAL.CONCLUSION:The more myopic eyes have larger hyperopic RPRE in Chinese children with MAI in certain retinal range,and partialΔRPRE is closely associated with ΔSER and ΔAL.展开更多
AIM:To compare the consistency of two autorefractors(Tianle RM-9000 and Topcon KR-800)for school-age myopia children,and to provide a basis for largescale data analysis and comparison.METHODS:The refractive error in 9...AIM:To compare the consistency of two autorefractors(Tianle RM-9000 and Topcon KR-800)for school-age myopia children,and to provide a basis for largescale data analysis and comparison.METHODS:The refractive error in 909 subjects(age 4–18y)were measured using both autorefractors without cycloplegia.The data were analyzed using Fourier decomposition and the correlation coefficients,intraclass correlation coefficients(ICC),and Bland-Altman limits of agreement(LoA)for each parameter were calculated.RESULTS:There was a strong correlation between the spherical equivalent(SE),sphere diopter(DS),and cylinder diopter(DC)readings of the Tianle RM-9000 and those of the Topcon KR-800,with correlation coefficient values of 0.98,0.98 and 0.83 and ICC values of 0.99,0.99 and 0.93,respectively.However,the correlation coefficients and ICC values of J0 and J45 were unreliable(R=-0.004,-0.034;both ICC<0.10).Bland-Altman analysis revealed that SE,DS,and DC measured by the Tianle RM-9000 were significantly biased toward myopia compared with the Topcon KR-800,and the mean differences were-0.072,-0.026,-0.091 D,respectively(all P<0.01).The minimum absolute value of the difference within the 95%LoA for SE,DS,and DC was 0.63 D,0.50 D,0.62 D,respectively;all these values were in the clinically acceptable range.For J0 and J45,the mean differences were close to zero(P=0.43,0.84);however,the 95%LoA were relatively wide(J0 SD:0.53;95%CI:-1.00,1.10;J45 SD:0.52;95%CI:-1.00,1.00).CONCLUSION:The two autorefractors are consistent with each other,as the differences in SE,DS,and DC were within the clinically acceptable range.Readers can compare the data measured by either device in different studies and use the two devices in the same study to generate a dataset that can be analyzed together.However,the J0 and J45 vectors are unreliable and should not be used to assess astigmatism.展开更多
In this article,a series of high refractive indices(1.50-1.53)thiol phenyl polysiloxane(TPS)were synthesized via hydrolytic sol-gel reaction.The Fourier transform infrared spectra(FT-IR)and nuclear magnetic resonance ...In this article,a series of high refractive indices(1.50-1.53)thiol phenyl polysiloxane(TPS)were synthesized via hydrolytic sol-gel reaction.The Fourier transform infrared spectra(FT-IR)and nuclear magnetic resonance spectra(NMR)results showed that TPS conformed to the predicted structures.Natural terpene linalool was exploited as photocrosslinker to fabricate UV-curing linalool-polysiloxane hybrid films(LPH)with TPS via photoinitiated thiol-ene reaction.LPH rapidly cured under UV irradiation at the intensity of 80 mW/cm^(2) in 30 s,exhibiting good UV-curing properties.The optical transmittance of LPH in the wavelength of 300-800 nm was over 90%,exhibiting good optical transparency.The water contact angle and water vapor permeability results showed that the introduction of phenyl groups enhance the hydrophobicity and water vapor barrier properties of LPH.The results indicated the potential of LPHs in the applications of optical functional coatings.展开更多
To achieve high quality factor and high-sensitivity refractive index sensor,a slot micro-ring resonator(MRR)based on asymmetric Fabry-Perot(FP)cavity was proposed.The structure consisted of a pair of elliptical holes ...To achieve high quality factor and high-sensitivity refractive index sensor,a slot micro-ring resonator(MRR)based on asymmetric Fabry-Perot(FP)cavity was proposed.The structure consisted of a pair of elliptical holes to form an FP cavity and a microring resonator.The two different optical modes generated by the micro-ring resonator were destructively interfered to form a Fano line shape,which improved the system sensitivity while obtaining a higher quality factor and extinction ratio.The transmission principle of the structure was analyzed by the transfer matrix method.The transmission spectrum and mode field distribution of the proposed structure were simulated by the finite difference time domain(FDTD)method,and the key structural parameters affecting the Fano line shape in the device were optimized.The simulation results show that the quality factor of the device reached 22037.1,and the extinction ratio was 23.9 dB.By analyzing the refractive index sensing characteristics,the sensitivity of the structure was 354 nm·RIU−1,and the detection limit of the sensitivity was 2×10−4 RIU.Thus,the proposed compact asymmetric FP cavity slot micro-ring resonator has obvious advantages in sensing applications owing to its excellent performance.展开更多
BACKGROUND Retinoscopy is arguably the most important method in the eye clinic for diagnosing and managing refractive errors.Advantages of retinoscopy include its noninvasive nature,ability to assess patients of all a...BACKGROUND Retinoscopy is arguably the most important method in the eye clinic for diagnosing and managing refractive errors.Advantages of retinoscopy include its noninvasive nature,ability to assess patients of all ages,and usefulness in patients with limited cooperation or communication skills.AIM To discuss the history of retinoscopes and examine current literature on the subject.METHODS A search was conducted on the PubMed and with the reference citation analysis(https://www.referencecitationanalysis.com)database using the term"Retinoscopy,"with a range restricted to the last 10 years(2013-2023).The search string algorithm was:"Retinoscopy"(MeSH Terms)OR"Retinoscopy"(All Fields)OR"Retinoscopes"(All Fields)AND[(All Fields)AND 2013:2023(pdat)].RESULTS This systematic review included a total of 286 records.Publications reviewed iterations of the retinoscope into autorefractors,infrared photo retinoscope,television retinoscopy,and the Wifi enabled digital retinoscope.CONCLUSION The retinoscope has evolved significantly since its discovery,with a significant improvement in its diagnostic capabilities.While it has advantages such as non-invasiveness and broad applicability,limitations exist,and the need for skilled interpretation remains.With ongoing research,including the integration of artificial intelligence,retinoscopy is expected to continue advancing and playing a vital role in eye care.展开更多
Introduction: WHO estimated that uncorrected refractive errors are the leading cause of visual impairment and second leading cause of blindness globally. University students are prone to developing refractive errors d...Introduction: WHO estimated that uncorrected refractive errors are the leading cause of visual impairment and second leading cause of blindness globally. University students are prone to developing refractive errors due to their curriculum that requires a lot of near work affecting their performance and quality of life unknowingly. Genetic and environmental factors are thought to play a role in the development of refractive errors. This study addresses the paucity of knowledge about refractive errors among university students in East Africa, providing a foundation for further research. Objectives: To determine the prevalence and factors associated with refractive errors among students in the Faculty of Medicine at Mbarara University of Science and Technology. Methodology: This was a cross-sectional descriptive and analytical study in which 368 undergraduate students selected using random sampling were assessed for refractive errors from March 2021-July 2021. Eligible participants were recruited and their VA assessment done after answering a questionnaire. Students whose VA improved on pin hole had subjective retinoscopy and results were compiled and imported to STATA 14 for analysis. Results: The prevalence of refractive errors was 26.36% with (95% CI) among university students especially myopia. Myopia is most predominant at 60%, followed by 37% Astigmatism and hyperopia of 3% among medical students. Astigmatism consisted of largely myopic astigmatism 72% (26) and 28% (10) compound/mixed astigmatism only. Student positive family history of refractive error was found to have a statistically significant relationship with refractive errors with AOR 1.68 (1.04 - 2.72) (95% CI) and P (0.032). Conclusion: The prevalence of refractive errors among university students, especially myopia, was found to be high and family history was associated with students having refractive errors.展开更多
Introduction: Undetected refractive errors constitute a health problem among school children who cannot take advantage of educational opportunities. The authors studied the prevalence of refractive errors in school ch...Introduction: Undetected refractive errors constitute a health problem among school children who cannot take advantage of educational opportunities. The authors studied the prevalence of refractive errors in school children aged 5 to 15 at CHU-IOTA. Patients and Method: This is a prospective, descriptive cross-sectional study carried out in the ophthalmic-pediatrics department of CHU-IOTA, from October to November 2023. Results: We received 340 school children aged 5 to 15, among whom 111 presented ametropia, i.e. a prevalence of 32.65%. The average age was 11.42 ± 2.75 years and a sex ratio of 0.59. The average visual acuity was 4/10 (range 1/10 and 10/10). We found refractive defects: astigmatism 73.87%, hyperopia 23.87% of cases and myopia 2.25%. The decline in distance visual acuity was the most common functional sign. Ocular abnormalities associated with ametropia were dominated by allergic conjunctivitis (26.13%) and papillary excavation (6.31%) in astigmatics;allergic conjunctivitis (9.01%) and papillary excavation (7.20%) in hyperopic patients;turbid vitreous (0.90%), myopic choroidosis (0.45%) and allergic conjunctivitis (0.45%) in myopes. Conclusion: Refractive errors constitute a reality and a major public health problem among school children.展开更多
文摘An approximate analytic model is presented to describe spatial structure of refracted electromagnetic field arising at oblique incidence of a Gaussian beam on a plane boundary of an absorbing homogeneous medium. The analytic solution is obtained by asymptotic approximation of a Fourier field integral under the condition of great beam width in comparison with a wavelength (the geometrical-optics approximation). This model can be used also for approximate simulation of refracted field in the cases of beam incidence near the critical angle on transparent or absorbing (amplifying) refracting medium, if one artificially introduces the additional absorption (amplification), whose value is proportional to the ratio of the wavelength and the effective beam width. It is shown that the analytic model reflects the general features of refracted field at total internal reflection.
基金Supported by Education Department Foundation of Sichuan Province(No.15ZA0262).
文摘AIM:To present the 1-year results of a prospective cohort study investigating the efficacy,potential mechanism,and safety of orthokeratology(ortho-k)with different back optic zone diameters(BOZD)for myopia control in children.METHODS:This randomized clinical study was performed between Dec.2020 and Dec.2021.Participants were randomly assigned to three groups wearing ortho-k:5 mm BOZD(5-MM group),5.5 mm BOZD(5.5-MM group),and 6 mm BOZD(6-MM group).The 1-year data were recorded,including axial length,relative peripheral refraction(RPR,measured by multispectral refractive topography,MRT),and visual quality.The contrast sensitivity(CS)was evaluated by CSV-1000 instrument with spatial frequencies of 3,6,12,and 18 cycles/degree(c/d);the corneal higher-order aberrations(HOAs)were measured by iTrace aberration analyzer.The one-way ANOVA was performed to assess the differences between the three groups.The correlation between the change in AL and RPR was calculated by Pearson’s correlation coefficient.RESULTS:The 1-year results of 20,21,and 21 subjects in the 5-MM,5.5-MM,and 6-MM groups,respectively,were presented.There were no statistical differences in baseline age,sex,or ocular parameters between the three groups(all P>0.05).At the 1-year visit,the 5-MM group had lower axial elongation than the 6-MM group(0.07±0.09 vs 0.18±0.11 mm,P=0.001).The 5-MM group had more myopic total RPR(TRPR,P=0.014),with RPR in the 15°–30°(RPR 15–30,P=0.015),30°–45°(RPR 30–45,P=0.011),temporal(RPR-T,P=0.008),and nasal area(RPR-N,P<0.001)than the 6-MM group.RPR 15–30 in the 5.5-MM group was more myopic than that in the 6-MM group(P=0.002),and RPR-N in the 5-MM group was more myopic than that in the 5.5-MM group(P<0.001).There were positive correlations between the axial elongation and the change in TRPR(r=0.756,P<0.001),RPR 15–30(r=0.364,P=0.004),RPR 30–45(r=0.306,P=0.016),and RPR-N(r=0.253,P=0.047).The CS decreased at 3 c/d(P<0.001),and the corneal HOAs increased in the 5-MM group(P=0.030).CONCLUSION:Ortho-k with 5 mm BOZD can control myopia progression more effectively.The mechanism may be associated with greater myopic shifts in RPR.
文摘AIM:To investigate the prevalence of visual impairment(VI)and provide an estimation of uncorrected refractive errors in school-aged children,conducted by optometry students as a community service.METHODS:The study was cross-sectional.Totally 3343 participants were included in the study.The initial examination involved assessing the uncorrected distance visual acuity(UDVA)and visual acuity(VA)while using a+2.00 D lens.The inclusion criteria for a subsequent comprehensive cycloplegic eye examination,performed by an optometrist,were as follows:a UDVA<0.6 decimal(0.20 logMAR)and/or a VA with+2.00 D≥0.8 decimal(0.96 logMAR).RESULTS:The sample had a mean age of 10.92±2.13y(range 4 to 17y),and 51.3%of the children were female(n=1715).The majority of the children(89.7%)fell within the age range of 8 to 14y.Among the ethnic groups,the highest representation was from the Luhya group(60.6%)followed by Luo(20.4%).Mean logMAR UDVA choosing the best eye for each student was 0.29±0.17(range 1.70 to 0.22).Out of the total,246 participants(7.4%)had a full eye examination.The estimated prevalence of myopia(defined as spherical equivalent≤-0.5 D)was found to be 1.45%of the total sample.While around 0.18%of the total sample had hyperopia value exceeding+1.75 D.Refractive astigmatism(cil<-0.75 D)was found in 0.21%(7/3343)of the children.The VI prevalence was 1.26%of the total sample.Among our cases of VI,76.2%could be attributed to uncorrected refractive error.Amblyopia was detected in 0.66%(22/3343)of the screened children.There was no statistically significant correlation observed between age or gender and refractive values.CONCLUSION:The primary cause of VI is determined to be uncorrected refractive errors,with myopia being the most prevalent refractive error observed.These findings underscore the significance of early identification and correction of refractive errors in school-aged children as a means to alleviate the impact of VI.
基金Supported by the "10th Five-Year" National Science and Technology Plan of China (Grant No.2003BA613A-09)China Innovation Foundation of Petroleum Technology for Young and Middle-Aged Scholars (Grant No.03E7018)
文摘Three-component seismic exploration through P-wave source and three-component geophone is an effective technique used in complicated reservoir exploration. In three-component seismic exploration data processing,one of the difficulties is static correction of converted wave. This paper analyzes propagation characteristics of non-converted and converted refracted waves,and discovers a favor-able condition for the formation of converted refracted wave,i.e. the velocity of overlaying medium S wave is much lower than that of underlying medium S wave. In addition,the paper proposes the static correction method of converted wave based on PPS converted refracted wave,and processes the real three-component seismic data with better results of static correction of converted wave.
基金Supported by the OneSight EssilorLuxottica Foundation.
文摘AIM:To describe the distribution of refractive errors by age and sex among schoolchildren in Soacha,Colombia.METHODS:This was an observational cross-sectional study conducted in five urban public schools in the municipality of Soacha.A total of 1161 school-aged and pre-adolescent children,aged 5-12y were examined during the school year 2021-2022.Examinations included visual acuity and static refraction.Spherical equivalent(SE)was analysed as follows:myopia SE≤-0.50 D and uncorrected visual acuity of 20/25 or worse;high myopia SE≤-6.00 D;hyperopia SE≥+1.00 D(≥7y)or SE≥+2.00 D(5-6y);significant hyperopia SE≥+3.00 D.Astigmatism was defined as a cylinder in at least one eye≥1.00 D(≥7y)or≥1.75 D(5-6y).If at least one eye was ametropic,children were classified according to the refractive error found.RESULTS:Of the 1139 schoolchildren included,50.6%were male,58.8%were aged between 5 and 9y,and 12.1%were already using optical correction.The most common refractive error was astigmatism(31.1%),followed by myopia(20.8%)and hyperopia(13.1%).There was no significant relationship between refractive error and sex.There was a significant increase in astigmatism(P<0.001)and myopia(P<0.0001)with age.CONCLUSION:Astigmatism is the most common refractive error in children in an urban area of Colombia.Emmetropia decreased and myopia increased with age.
基金Supported by the Shenzhen Science and Technology Program (No.JCYJ20210324142800001).
文摘AIM:To compare relative peripheral refraction(RPR)in Chinese school children with different refractive errors using multispectral refraction topography(MRT).METHODS:A total of 713 eyes of primary school children[172 emmetropia(E),429 low myopia(LM),80 moderate myopia(MM),and 32 low hypermetropia(LH)]aged 10 to 13y were analyzed.RPRs were measured using MRT without mydriasis.MRT results showed RPR at 0-15°(RPR 0-15),15°-30°(RPR 15-30),and 30°-45°(RPR 30-45)annular in the inferior(RPR-I),superior(RPR-S),nasal(RPR-N),and temporal(RPR-T)quadrants.Spherical equivalent(SE)was detected and calculated using an autorefractor.RESULTS:There were significant differences of RPR 15-30 between groups MM[0.02(-0.12;0.18)]and LH[-0.13(-0.36;0.12)](P<0.05),MM and E[-0.06(-0.20;0.10)](P<0.05),and LM[-0.02(-0.15;0.15)]and E(P<0.05).There were also significant differences of RPR 30-45 between groups MM[0.45(0.18;0.74)]and E[0.29(-0.09;0.67)](P<0.05),and LM[0.44(0.14;0.76)]and E(P<0.001).RPR values increased from the hyperopic to medium myopic group in each annular.There were significant differences of RPR-S between groups MM[-0.02(-0.60;0.30)]and E[-0.44(-0.89;-0.04)](P<0.001),and LM[-0.28(-0.71;0.12)]and E(P<0.05).There were also significant differences of RPR-T between groups MM[0.37(0.21;0.78)]and LH[0.14(-0.52;0.50)](P<0.05),LM[0.41(0.06;0.84)]and LH(P<0.05),and LM and E[0.29(-0.10;0.68),P<0.05].A Spearman’s correlation analysis showed a negative correlation between RPR and SE in the 15°-30°(P=0.005),30°-45°(P<0.05)annular(P=0.002),superior(P<0.001),and temporal(P=0.001)quadrants.CONCLUSION:Without pupil dilation,values for RPR 15-30,30-45,RPR-S,and T shows significant differences between myopic eyes and emmetropia,and the differences are negatively correlated with SE.
文摘AIM:To evaluate the refraction difference value(RDV)variations in children and adolescents with different refractive errors and analyze its correlation with refractive development.METHODS:Participants aged 4-16y with different refractive statuses(hyperopia,emmetropia,myopia)underwent comprehensive eye examinations,including spherical equivalent(SE)refraction,axial length(AL),total RDV(TRDV),and RDVs at various eccentricities(0°-15°,15°-30°,30°-45°)and quadrants(inferior,superior,nasal,temporal).Statistical analysis involved one-way ANOVA for group comparisons and Pearson correlation for examining relationships between SE/AL and RDVs.Paired t-tests compared quadrant-specific RDVs within groups.RESULTS:Significant difference was found in TRDV(P<0.001),RDV15°-30°(P=0.033),RDV30°-45°(P<0.001),RDV-inferior(RDV-I,P<0.001)and RDV-temporal(RDV-T,P<0.001)among hyperopia,emmetropia and myopia group.Pearson correlation analysis revealed a negative correlation of SE with TRDV(P=0.001),RDV30°-45°(P=0.004),RDV-I(P=0.047),and RDV-T(P<0.001).The differences between RDV-superior(RDV-S)and RDV-I were statistically significant in all groups(P<0.001 for all)and between RDV-T and RDV-nasal(RDV-N)were statistically significant in hyperopia group(P<0.001).Within the premyopic group,the analysis revealed a negative correlation of SE with RDV-I(P=0.009).Pearson correlation analysis revealed a positive correlation of AL with TRDV(P=0.036),RDV15°-30°(P=0.004),RDV30°-45°(P<0.001),RDV-S(P=0.003),RDV-I(P<0.001),RDV-T(P<0.001),RDV-N(P=0.022),while revealed a negative correlation of AL with RDV0-15°(P=0.018).CONCLUSION:Our study indicates TRDV,RDV30°-45°,RDV-I,RDV-T may relate to refractive development,and a negative correlation between SE and RDV-I in pre-myopic children.
基金supported by the National Key R&D Program of China(No.2021YFE0110900)the National Natural Science Foundation of China(Nos.U22B2078 and 11991033)。
文摘Elastic metamaterials with unusual elastic properties offer unprecedented ways to modulate the polarization and propagation of elastic waves.However,most of them rely on the resonant structural components,and thus are frequency-dependent and unchangeable.Here,we present a reconfigurable 2D mechanism-based metamaterial which possesses transformable and frequency-independent elastic properties.Based on the proposed mechanism-based metamaterial,interesting functionalities,such as ternarycoded elastic wave polarizer and programmable refraction,are demonstrated.Particularly,unique ternary-coded polarizers,with 1-trit polarization filtering and 2-trit polarization separating of longitudinal and transverse waves,are first achieved.Then,the strong anisotropy of the proposed metamaterial is harnessed to realize positive-negative bi-refraction,only-positive refraction,and only-negative refraction.Finally,the wave functions with detailed microstructures are numerically verified.
基金supported by the National Natural Science Foundation of China(22288102 and 22278027).
文摘Transparent photoresists with a high refractive index(RI)and high transmittance in visible wavelengths have promising functionalities in optical fields.This work reports a kind of tunable optical material composed of titanium dioxide nanoparticles embedded in acrylic resin with a high RI for ultraviolet(UV)-imprint lithography.The hybrid film exhibits a tunable RI of up to 1.67(589 nm)after being cured by UV light,while maintaining both a high transparency of over 98%in the visible light range and a low haze of less than 0.05%.The precision machining of optical microstructures can be imprinted easily and efficiently using the hybrid resin,which acts as a light guide plate(LGP)to guide the light from the side to the top in order to conserve the energy of the display device.These preliminary studies based on both laboratory and commercial experiments pave the way for exploiting the unparalleled optical properties of nanocomposite resins and promoting their industrial application.
基金the National Natural Science Foundation of China (Nos.52304123 and 52104077)the Postdoctoral Fellowship Program of CPSF (No.GZB20230914)+1 种基金the China Postdoctoral Science Foundation (No.2023M730412)the National Key Research and Development Program for Young Scientists (No.2021YFC2900400)。
文摘Acoustic emission(AE)localization algorithms based on homogeneous media or single-velocity are less accurate when applied to the triaxial localization experiments.To the end,a robust triaxial localization method of AE source using refraction path is proposed.Firstly,the control equation of the refraction path is established according to the sensor coordinates and arrival times.Secondly,considering the influence of time-difference-of-arrival(TDOA)errors,the residual of the governing equation is calculated to estimate the equation weight.Thirdly,the refraction points in different directions are solved using Snell’s law and orthogonal constraints.Finally,the source coordinates are iteratively solved by weighted correction terms.The feasibility and accuracy of the proposed method are verified by pencil-lead breaking experiments.The simulation results show that the new method is almost unaffected by the refraction ratio,and always holds more stable and accurate positioning performance than the traditional method under different ratios and scales of TDOA outliers.
基金Project supported by the National Natural Science Foundation of China (Grant No.12175107)the Natural Science Foundation of Nanjing Vocational University of Industry Technology (Grant No.YK22-02-08)+2 种基金the Qing Lan Project of Jiangsu Provincethe Natural Science Foundation of Jiangsu Province of China (Grant No.BK20230347)the Fund from the Research Center of Industrial Perception and Intelligent Manufacturing Equipment Engineering of Jiangsu Province,China (Grant No.ZK21-05-09)。
文摘Metal-based surface plasmon resonance(SPR)plays an important role in enhancing the photonic spin Hall effect(SHE)and developing sensitive optical sensors.However,the very large negative permittivities of metals limit their applications beyond the near-infrared regime.In this work,we theoretically present a new mechanism to enhance the photonic SHE by taking advantage of SiC-supported surface phonon resonance(SPhR)in the mid-infrared regime.The transverse displacement of photonic SHE is very sensitive to the wavelength of incident light and the thickness of SiC layer.Under the optimal parameter setup,the calculated largest transverse displacement of SiC-based SPhR structure reaches up to 163.8 ym,which is much larger than the condition of SPR.Moreover,an NO_(2) gas sensor based on the SPhR-enhanced photonic SHE is theoretically proposed with the superior sensing performance.Both the intensity and angle sensitivity of this sensor can be effectively manipulated by varying the damping rate of SiC.The results may provide a promising paradigm to enhance the photonic SHE in the mid-infrared region and open up new opportunity of highly sensitive refractive index sensors.
基金Supported by National Natural Science Foundation of China(No.82171092No.82371087)+1 种基金Capital’s Funds for Health Improvement and Research(No.2022-1G-4083)National Key R&D Program of China(No.2021YFC2702100).
文摘AIM:To describe the distribution of ocular biometrics and to evaluate its associations with refractive error and to assess the contribution from ocular parameters to refractive error among Chinese myopic children.METHODS:This cross-sectional study evaluated subjects aged 8-12y.Keratometry,ocular biometry,and cycloplegic autorefraction were performed on each subject.Spherical equivalent refraction(SER)and ocular biometrics were assessed as a function of age and gender.The Pearson correlation analysis between SER and ocular biometrics was carried out.Multiple linear regression was performed to analyze the association between SER and ocular parameters.RESULTS:A total of 689 out of 735 participants(321 boys,48.1%)were analyzed,with a mean SER of-2.98±1.47 diopter(D).Axial length(AL),anterior chamber depth(ACD),corneal radius of curvature(CR),horizontal visible iris diameter(HVID),central corneal thickness(CCT)and lens power(LP)showed normal distribution.The AL,AL/CR ratio,ACD and CR increased from 8 to 12y of age,while SER and LP decreased,HVID and CCT remained stable.There was no difference in gender.SER decreased by 0.929 D for every 1 mm increase in AL and decreased by 1.144 D for every 0.1 increase in AL/CR ratio.The Pearson correlation coefficient between SER and AL was-0.538(P<0.01)and-0.747(P<0.01)between SER and AL/CR ratio.For the SER variance,AL explained 29.0%,AL/CR ratio explained 55.7%,while AL,CR,ACD and LP explained 99.3%after adjusting for age and gender.CONCLUSION:The AL,CR,ACD and LP are the most important determinants of myopic refractive error during myopia progression.
文摘AIM:To evaluate the clinical outcomes after subsequent implantation of a new intrastromal corneal ring segment(ICRS)model followed by an additional short-arc ICRS implant in keratoconus patients.METHODS:This retrospective single-arm cohort study evaluated 25 eyes of 21 keratoconus patients implanted with the new ICRS followed by 140-arch length ICRS(140-ICRS)implantation.Uncorrected distance visual acuity(UDVA,logMAR),corrected distance visual acuity(CDVA,logMAR),sphere,astigmatism,keratometry,spherical equivalent(SE),and asphericity were compared preoperatively and postoperatively after both ICRS implantation.RESULTS:The average follow-up time after 140-ICRS implantation was 6.40±2.20mo.The mean preoperative UDVA improved from 1.27±0.14 preoperative to 0.52±0.26 after both ICRS implantation(P=0.03).The mean sphere value reduced from-5.34±2.74 preoperatively to-2.06±1.84 postoperatively(P<0.001)after the first ICRS implantation and decreased to-0.59±1.54 postoperatively(P<0.001)after 140-ICRS implantation.The mean preoperative astigmatism was-3.72±1.56 and improved to-2.82±1.08 after the first ICRS implantation,and following the 140-ICRS implantation,the mean astigmatism was-1.37±0.67(P=0.001).The SE and asphericity changes were statistically significant(P<0.001).The researchers did not find intraoperative or postoperative complications for both procedures.CONCLUSION:The combination of 2 different ICRSs can efficiently regularize the cornea,reduce the SE,and improve visual acuity in selected keratoconus patients.
文摘AIM:To compare relative peripheral refractive errors(RPREs)in Chinese children with and without myopic anisometropia(MAI)and to explore the relationship between RPRE and myopia.METHODS:This observational cross-sectional study included 160 children divided into two groups according to the interocular spherical equivalent refraction(SER)difference≥1.0 D in the MAI group(n=80)and<1.0 D in the non-MAI group(n=80).The MAI group was further divided into two subgroups:ΔSER<2.0 D group and ΔSER≥2.0 D group.Basic ocular biometric parameters of axial length(AL),average keratometry(Ave K),cylinder(CYL),surface regularity index(SRI),and surface asymmetry index(SAI)were recorded.In addition,multispectral refraction topography was performed to measure RPRE,and the parameters were recorded as total refraction difference value(TRDV),refraction difference value(RDV)0-10,RDV10-20,RDV20-30,RDV30-40,RDV40-53,RDV-superior(RDV-S),RDV-inferior(RDV-I),RDV-temporal(RDV-T)and RDV-nasal(RDV-N).RESULTS:In the non-MAI group,the interocular differences of all parameters of RPRE were not significant.In the MAI group,the interocular differences of TRDV,RDV10-53,RDV-S,RDV-I,RDV-T,and RDV-N were significant.In subgroup analysis,the interocular differences of TRDV,RDV30-53,RDV-I,and RDV-T were significant in ΔSER<2.0 D group and ΔSER≥2.0 D group,but the interocular differences of RDV10-30,RDV-S and RDV-N were only significant in the ΔSER≥2.0 D group.In correlation analysis,ΔTRDV,ΔRDV 10-53,ΔRDV-S,and ΔRDV-N were negatively correlated with ΔSER but positively correlated with ΔAL.CONCLUSION:The more myopic eyes have larger hyperopic RPRE in Chinese children with MAI in certain retinal range,and partialΔRPRE is closely associated with ΔSER and ΔAL.
基金Supported by the National Natural Science Foundation of China(No.81873683).
文摘AIM:To compare the consistency of two autorefractors(Tianle RM-9000 and Topcon KR-800)for school-age myopia children,and to provide a basis for largescale data analysis and comparison.METHODS:The refractive error in 909 subjects(age 4–18y)were measured using both autorefractors without cycloplegia.The data were analyzed using Fourier decomposition and the correlation coefficients,intraclass correlation coefficients(ICC),and Bland-Altman limits of agreement(LoA)for each parameter were calculated.RESULTS:There was a strong correlation between the spherical equivalent(SE),sphere diopter(DS),and cylinder diopter(DC)readings of the Tianle RM-9000 and those of the Topcon KR-800,with correlation coefficient values of 0.98,0.98 and 0.83 and ICC values of 0.99,0.99 and 0.93,respectively.However,the correlation coefficients and ICC values of J0 and J45 were unreliable(R=-0.004,-0.034;both ICC<0.10).Bland-Altman analysis revealed that SE,DS,and DC measured by the Tianle RM-9000 were significantly biased toward myopia compared with the Topcon KR-800,and the mean differences were-0.072,-0.026,-0.091 D,respectively(all P<0.01).The minimum absolute value of the difference within the 95%LoA for SE,DS,and DC was 0.63 D,0.50 D,0.62 D,respectively;all these values were in the clinically acceptable range.For J0 and J45,the mean differences were close to zero(P=0.43,0.84);however,the 95%LoA were relatively wide(J0 SD:0.53;95%CI:-1.00,1.10;J45 SD:0.52;95%CI:-1.00,1.00).CONCLUSION:The two autorefractors are consistent with each other,as the differences in SE,DS,and DC were within the clinically acceptable range.Readers can compare the data measured by either device in different studies and use the two devices in the same study to generate a dataset that can be analyzed together.However,the J0 and J45 vectors are unreliable and should not be used to assess astigmatism.
基金the financial funding of the Guangdong Province Applied Science and Technology R&D Special Fund Project:Key Technologies for Industrialization of Sulfur-Resistant and High Refractive-Index LED Packaging Silicone Materials(2016B090930010).
文摘In this article,a series of high refractive indices(1.50-1.53)thiol phenyl polysiloxane(TPS)were synthesized via hydrolytic sol-gel reaction.The Fourier transform infrared spectra(FT-IR)and nuclear magnetic resonance spectra(NMR)results showed that TPS conformed to the predicted structures.Natural terpene linalool was exploited as photocrosslinker to fabricate UV-curing linalool-polysiloxane hybrid films(LPH)with TPS via photoinitiated thiol-ene reaction.LPH rapidly cured under UV irradiation at the intensity of 80 mW/cm^(2) in 30 s,exhibiting good UV-curing properties.The optical transmittance of LPH in the wavelength of 300-800 nm was over 90%,exhibiting good optical transparency.The water contact angle and water vapor permeability results showed that the introduction of phenyl groups enhance the hydrophobicity and water vapor barrier properties of LPH.The results indicated the potential of LPHs in the applications of optical functional coatings.
基金supported by Natural Science Foundation of Gansu Province(No.22JR5RA320).
文摘To achieve high quality factor and high-sensitivity refractive index sensor,a slot micro-ring resonator(MRR)based on asymmetric Fabry-Perot(FP)cavity was proposed.The structure consisted of a pair of elliptical holes to form an FP cavity and a microring resonator.The two different optical modes generated by the micro-ring resonator were destructively interfered to form a Fano line shape,which improved the system sensitivity while obtaining a higher quality factor and extinction ratio.The transmission principle of the structure was analyzed by the transfer matrix method.The transmission spectrum and mode field distribution of the proposed structure were simulated by the finite difference time domain(FDTD)method,and the key structural parameters affecting the Fano line shape in the device were optimized.The simulation results show that the quality factor of the device reached 22037.1,and the extinction ratio was 23.9 dB.By analyzing the refractive index sensing characteristics,the sensitivity of the structure was 354 nm·RIU−1,and the detection limit of the sensitivity was 2×10−4 RIU.Thus,the proposed compact asymmetric FP cavity slot micro-ring resonator has obvious advantages in sensing applications owing to its excellent performance.
文摘BACKGROUND Retinoscopy is arguably the most important method in the eye clinic for diagnosing and managing refractive errors.Advantages of retinoscopy include its noninvasive nature,ability to assess patients of all ages,and usefulness in patients with limited cooperation or communication skills.AIM To discuss the history of retinoscopes and examine current literature on the subject.METHODS A search was conducted on the PubMed and with the reference citation analysis(https://www.referencecitationanalysis.com)database using the term"Retinoscopy,"with a range restricted to the last 10 years(2013-2023).The search string algorithm was:"Retinoscopy"(MeSH Terms)OR"Retinoscopy"(All Fields)OR"Retinoscopes"(All Fields)AND[(All Fields)AND 2013:2023(pdat)].RESULTS This systematic review included a total of 286 records.Publications reviewed iterations of the retinoscope into autorefractors,infrared photo retinoscope,television retinoscopy,and the Wifi enabled digital retinoscope.CONCLUSION The retinoscope has evolved significantly since its discovery,with a significant improvement in its diagnostic capabilities.While it has advantages such as non-invasiveness and broad applicability,limitations exist,and the need for skilled interpretation remains.With ongoing research,including the integration of artificial intelligence,retinoscopy is expected to continue advancing and playing a vital role in eye care.
文摘Introduction: WHO estimated that uncorrected refractive errors are the leading cause of visual impairment and second leading cause of blindness globally. University students are prone to developing refractive errors due to their curriculum that requires a lot of near work affecting their performance and quality of life unknowingly. Genetic and environmental factors are thought to play a role in the development of refractive errors. This study addresses the paucity of knowledge about refractive errors among university students in East Africa, providing a foundation for further research. Objectives: To determine the prevalence and factors associated with refractive errors among students in the Faculty of Medicine at Mbarara University of Science and Technology. Methodology: This was a cross-sectional descriptive and analytical study in which 368 undergraduate students selected using random sampling were assessed for refractive errors from March 2021-July 2021. Eligible participants were recruited and their VA assessment done after answering a questionnaire. Students whose VA improved on pin hole had subjective retinoscopy and results were compiled and imported to STATA 14 for analysis. Results: The prevalence of refractive errors was 26.36% with (95% CI) among university students especially myopia. Myopia is most predominant at 60%, followed by 37% Astigmatism and hyperopia of 3% among medical students. Astigmatism consisted of largely myopic astigmatism 72% (26) and 28% (10) compound/mixed astigmatism only. Student positive family history of refractive error was found to have a statistically significant relationship with refractive errors with AOR 1.68 (1.04 - 2.72) (95% CI) and P (0.032). Conclusion: The prevalence of refractive errors among university students, especially myopia, was found to be high and family history was associated with students having refractive errors.
文摘Introduction: Undetected refractive errors constitute a health problem among school children who cannot take advantage of educational opportunities. The authors studied the prevalence of refractive errors in school children aged 5 to 15 at CHU-IOTA. Patients and Method: This is a prospective, descriptive cross-sectional study carried out in the ophthalmic-pediatrics department of CHU-IOTA, from October to November 2023. Results: We received 340 school children aged 5 to 15, among whom 111 presented ametropia, i.e. a prevalence of 32.65%. The average age was 11.42 ± 2.75 years and a sex ratio of 0.59. The average visual acuity was 4/10 (range 1/10 and 10/10). We found refractive defects: astigmatism 73.87%, hyperopia 23.87% of cases and myopia 2.25%. The decline in distance visual acuity was the most common functional sign. Ocular abnormalities associated with ametropia were dominated by allergic conjunctivitis (26.13%) and papillary excavation (6.31%) in astigmatics;allergic conjunctivitis (9.01%) and papillary excavation (7.20%) in hyperopic patients;turbid vitreous (0.90%), myopic choroidosis (0.45%) and allergic conjunctivitis (0.45%) in myopes. Conclusion: Refractive errors constitute a reality and a major public health problem among school children.