As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scal...As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scale reinforced concrete(RC)frame structure.Different material pipes and different methods for penetrating the reinforced concrete floors are combined to evaluate the difference in seismic performance.Floor response spectra and pipe acceleration amplification factors based on test data are discussed and compared with code provisions.A seismic fragility study of displacement demand is conducted based on numerical simulation.The acceleration response and displacement response of different combinations are compared.The results show that the combination of different pipe materials and different passing-through methods can cause obvious differences in the seismic response of indoor riser pipes.展开更多
The seismic performance of a caisson structure under two types of models with a saturated sandy foundation(CSS)and an expanded polystyrene(EPS)composite soil foundation(CES)are studied using shaking table tests.The ma...The seismic performance of a caisson structure under two types of models with a saturated sandy foundation(CSS)and an expanded polystyrene(EPS)composite soil foundation(CES)are studied using shaking table tests.The macro phenomena of the two different foundation models are described and analyzed.The effects of the replacement of EPS composite soil on seismic-induced liquefaction of backfill and the dynamic performance of a caisson structure are evaluated in detail.The results show that the excess pore water pressure generation in the CES is significantly slower than that in the CSS during the shaking.The dynamic earth pressure acting on the caisson has a triangular shape.The response of horizontal acceleration,displacement,settlement,and rotation angle of the caisson in the CES is smaller than that in the CSS,which means the caisson in the CES has a better seismic performance.Furthermore,the out-of-phase phenomenon between dynamic earth thrust and inertial force in the CES is more obvious than that in the CSS,which is beneficial to reduce the lateral force and improve the stability of the caisson structure.展开更多
When an underground structure passes through a liquefiable soil layer,the soil liquefaction may pose a significant threat to the structure.A centrifuge shaking table test was performed to research the seismic response...When an underground structure passes through a liquefiable soil layer,the soil liquefaction may pose a significant threat to the structure.A centrifuge shaking table test was performed to research the seismic response of underground structures in liquefiable interlayer sites,and a valid numerical model was obtained through simulation model test.Finally,the calibrated numerical model was used to perform further research on the influence of various distribution characteristics of liquefiable interlayers on the seismic reaction of underground structures.The key findings are as follows.The structure faces the most unfavorable condition once a liquefiable layer is located in the middle of the underground structure.When a liquefiable layer exists in the middle of the structure,the seismic reactions of both the underground structure and model site will increase with the rise of the thickness of the liquefiable interlayer.The inter-story drift of the structure in the non-liquefiable site is much smaller than that in the liquefiable interlayer site.The inter-story drift of the structure is not only associated with the site displacement and the soil-structure stiffness ratio but also closely associated with the slippage of the soil-structure contact interface under the condition of large deformation of the site.展开更多
To explore the cumulative deformation effect of the dynamic response of a tunnel crossing the hauling sliding surface under earthquakes,the shaking table test was conducted in this study.Combined with the numerical ca...To explore the cumulative deformation effect of the dynamic response of a tunnel crossing the hauling sliding surface under earthquakes,the shaking table test was conducted in this study.Combined with the numerical calculations,this study proposed magnification of the Arias intensity(MIa)to characterize the overall local deformation damage of the tunnel lining in terms of the deformation characteristics,frequency domain,and energy.Using the time‐domain analysis method,the plastic effect coefficient(PEC)was proposed to characterize the degree of plastic deformation,and the applicability of the seismic cumulative failure effect(SCFE)was discussed.The results show that the low‐frequency component(f1 and f2≤10 Hz)and the high‐frequency component(f3 and f4>10 Hz)acceleration mainly cause global and local deformation of the tunnel lining.The local deformation caused by the high‐frequency wave has an important effect on the seismic damage of the lining.The physical meaning of PEC is more clearly defined than that of the residual strain,and the SCFE of the tunnel lining can also be defined.The SCFE of the tunnel lining includes the elastic deformation effect stage(<0.15g),the elastic–plastic deformation effect stage(0.15g–0.30g),and the plastic deformation effect stage(0.30g–0.40g).This study can provide valuable theoretical and technical support for the construction of traffic tunnels in high‐intensity earthquake areas.展开更多
Underground utility tunnels are widely used in urban areas throughout the world for lifeline networks due to their easy maintenance and environmental protection capabilities. However, knowledge about their seismic per...Underground utility tunnels are widely used in urban areas throughout the world for lifeline networks due to their easy maintenance and environmental protection capabilities. However, knowledge about their seismic performance is still quite limited and seismic design procedures are not included in current design codes. This paper describes a series of shaking table tests the authors performed on a scaled utility tunnel model to explore its performance under earthquake excitation. Details of the experimental setup are first presented focusing on aspects such as the design of the soil container, scaled structural model, sensor array arrangement and test procedure. The main observations from the test program, including structural response, soil response, soil-structure interaction and earth pressure, are summarized and discussed. Further, a finite element model (FEM) of the test utility tunnel is established where the nonlinear soil properties are modeled by the Drucker- Prager constitutive model; the master-slave surface mechanism is employed to simulate the soil-structure dynamic interaction; and the confining effect of the laminar shear box to soil is considered by proper boundary modeling. The results from the numerical model are compared with experiment measurements in terms of displacement, acceleration and amplification factor of the structural model and the soil. The comparison shows that the numerical results match the experimental measurements quite well. The validated numerical model can be adopted for further analysis.展开更多
A wind turbine system equipped with a tuned liquid column damper (TLCD) is comprehensively studied via shaking table tests using a 1/13-scaled model. The effects of wind and wave actions are considered by inputting ...A wind turbine system equipped with a tuned liquid column damper (TLCD) is comprehensively studied via shaking table tests using a 1/13-scaled model. The effects of wind and wave actions are considered by inputting response- equivalent accelerations on the shaking table. The test results show that the control effect of the TLCD system is significant in reducing the responses under both wind-wave equivalent loads and ground motions, but obviously varies for different inputs, Further, a blade-hub-tower integrated numerical model for the wind turbine system is established. The model is capable of considering the rotational effect of blades by combining Kane's equation with the finite element method. The responses of the wind tower equipped with TLCD devices are numerically obtained and compared to the test results, showing that under both controlled and uncontrolled conditions with and without blades' rotation, the corresponding responses exhibit good agreement. This demonstrates that the proposed numerical model performs well in capturing the wind-wave coupled response of the offshore wind turbine systems under control. Both numerical and experimental results show that the TLCD system can significantly reduce the structural response and thus improve the safety and serviceability of the offshore wind turbine tower systems. Additional issues that require further study are discussed.展开更多
Mountain tunnel crossing a normal fault in seismically active zone is easily affected by normal fault slip and earthquake. It is necessary to study tunnel dynamic response under action of normal fault slip and earthqu...Mountain tunnel crossing a normal fault in seismically active zone is easily affected by normal fault slip and earthquake. It is necessary to study tunnel dynamic response under action of normal fault slip and earthquake. In this paper, a three-dimensional normal fault sliding device was designed, and a shaking table test was carried out to study tunnel seismic performance under normal fault slip. The results show that peak acceleration of lining is dominated by an existence of fault and direction of seismic excitation, not normal fault slip. And the incremental strains of lining in critical zone with 1.7 times fault thickness and centered in faults induced by normal fault slip and seismic excitation are larger than ones only by seismic excitation. And the incremental strains in critical zone increase with the increase of normal fault slip magnitude ranging from 0 to 2 mm. And normal fault slip results in a significant reduction of overall tunnel stiffness subjected to an earthquake. These experimental results provide a scientific reference for prevention and control measurement of tunnel damage under earthquake and normal fault slip.展开更多
Studies on landslides by the 2008 Wenchuan earthquake showed that topography was of great importance in amplifying the seismic shaking, and among other factors, lithology and slope structure controlled the spatial occ...Studies on landslides by the 2008 Wenchuan earthquake showed that topography was of great importance in amplifying the seismic shaking, and among other factors, lithology and slope structure controlled the spatial occurrence of slope failures. The present study carried out experiments on four rock slopes with steep angle of 60° by means of a shaking table. The recorded Wenchuan earthquake waves were scaled to excite the model slopes. Measurements from accelerometers installed on free surface of the model slope were analyzed, with much effort on timedomain acceleration responses to horizontal components of seismic shaking. It was found that the amplification factor of peak horizontal acceleration, RPHA, was increasing with elevation of each model slope, though the upper and lower halves of the slope exhibited different increasing patterns. As excitation intensity was increased, the drastic deterioration of the inner structure of each slope caused the sudden increase of RPHA in the upper slope part. In addition, the model simulating the soft rock slope produced the larger RPHA than the model simulating the hard rock slope by a maximum factor of 2.6. The layered model slope also produced the larger RPHA than the homogeneous model slope by a maximum factor of 2.7. The upper half of a slope was influenced more seriously by the effect of lithology, while the lower half was influenced more seriously by the effect of slope structure.展开更多
A series of scaled-model shaking table tests and its simulation analyses using dynamic finite element method were performed to clarify the dynamic behaviors and the seismic stability of embedded corrugated steel culve...A series of scaled-model shaking table tests and its simulation analyses using dynamic finite element method were performed to clarify the dynamic behaviors and the seismic stability of embedded corrugated steel culverts due to strong earth-quakes like the 1995 Hyogoken-nanbu earthquake. The dynamic strains of the embedded culvert models and the seismic soil pressure acting on the models due to sinusoidal and random strong motions were investigated. This study verified that the cor-rugated culvert model was subjected to dynamic horizontal forces (lateral seismic soil pressure) from the surrounding ground, which caused the large bending strains on the structure; and that the structures do not exceed the allowable plastic deformation and do not collapse completely during strong earthquake like Hyogoken-nanbu earthquake. The results obtained are useful for design and construction of embedded long span corrugated steel culverts in seismic regions.展开更多
In this study, four 1/5 scaled shaking table tests were conducted to investigate the seismic performance of recycled concrete frame-shear wall structures with different recycled aggregates replacement rates and concea...In this study, four 1/5 scaled shaking table tests were conducted to investigate the seismic performance of recycled concrete frame-shear wall structures with different recycled aggregates replacement rates and concealed bracing detail. The four tested structures included one normal concrete model, one recycled coarse aggregate concrete model, and two recycled coarse and fi ne aggregate concrete models with or without concealed bracings inside the shear walls. The dynamic characteristics, dynamic response and failure mode of each model were compared and analyzed. Finite element models were also developed and nonlinear time-history response analysis was conducted. The test and analysis results show that the seismic performance of the recycled coarse aggregate concrete frame-shear wall structure is slightly worse than the normal concrete structure. The seismic resistance capacity of the recycled concrete frame-shear wall structure can be greatly improved by setting up concealed bracings inside the walls. With appropriate design, the recycled coarse aggregate concrete frame-shear wall structure and recycled concrete structure with concealed bracings inside the walls can be applied in buildings.展开更多
Underground utility tunnels are the most fundamental and reliable lifeline network in urban cities,and are widely constructed throughout the world.In urban areas,most utility tunnels usually encounter the non-homogene...Underground utility tunnels are the most fundamental and reliable lifeline network in urban cities,and are widely constructed throughout the world.In urban areas,most utility tunnels usually encounter the non-homogeneity of subsoil condition due to various construction effects.Studies have shown that the damage mechanism of shallow underground structures mainly depends on the inhomogeneity of the subsoil conditions.This would become a considerable factor for the stability of the underground utility tunnel structures.However,this type of research still needs to establish the vulnerable seismic design.In this study,a series of shaking table tests were conducted on non-homogenous soils to investigate the performance of seismic interaction between utility tunnels,surrounding soils and interior pipelines.The dynamic responses measured from the test account for the boundary condition of non-homogeneous soils,the internal forces,displacement of tunnel joints,the dynamic characteristics on interior pipelines and the reasonable spring stiffness with damping in the seismically isolated gas pipeline model inside the tunnel.The vulnerability of underground utility tunnel in non-homogeneous soil zone and the mechanism of the stability of interior facilities are the main topics discussed in this paper.展开更多
This paper describes shaking table tests of a 1:12 scale model of a special concentrically braced steel frame with pinned connections, which was fabricated according to a one-bay braced frame selected from a typical ...This paper describes shaking table tests of a 1:12 scale model of a special concentrically braced steel frame with pinned connections, which was fabricated according to a one-bay braced frame selected from a typical main factory building of a large thermal power plant. In order to investigate the seismic performance of this type of structure, several ground motion accelerations with different levels for seismic intensity Ⅷ, based on the Chinese Code for Seismic Design of Buildings, were selected to excite the model. The results show that the design methods of the members and the connections are adequate and that the structural system will perform well in regions of high seismicity. In addition to the tests, numerical simulations were also conducted and the results showed good agreement with the test results. Thus, the numerical model is shown to be accurate and the beam element can be used to model this structural system.展开更多
Despite the continuous advancements of engineering construction in high-intensity areas,many engineering landslides are still manufactured with huge thrust force,and double-row piles are effective to control such larg...Despite the continuous advancements of engineering construction in high-intensity areas,many engineering landslides are still manufactured with huge thrust force,and double-row piles are effective to control such large landslides.In this study,large shaking table test were performed to test and obtain multi-attribute seismic data such as feature image,acceleration,and dynamic soil pressure.Through the feature image processing analysis,the deformation characteristics for the slope reinforced by double-row piles were revealed.By analyzing the acceleration and the dynamic soil pressure time domain,the spatial dynamic response characteristics were revealed.Using Fast Fourier Transform and half-power bandwidth,the damping ratio of acceleration and dynamic soil pressure was obtained.Following that,the Seism Signal was used to calculate the spectral displacement of the accelerations to obtain the regional differences of spectral displacement.The results showed that the overall deformation mechanism of the slope originates from tension failure in the soil mass.The platform at the back of the slope was caused by seismic subsidence,and the peak acceleration ratio was positively correlated with the relative pile heights.The dynamic soil pressure of the front row piles showed an inverted"K"-shaped distribution,but that of the back row piles showed an"S"-shaped distribution.The predominant frequency of acceleration was 2.16 Hz,and the main frequency band was 0.7-6.87 Hz;for dynamic soil pressure,the two parameters became 1.15 Hz and 0.5-6.59 Hz,respectively.In conclusion,dynamic soil pressure was more sensitive to dampening effects than acceleration.Besides,compared to acceleration,dynamic soil pressure exhibited larger loss factors and lower resonance peaks.Finally,back row pile heads were highly sensitive to spectral displacement compared to front row pile heads.These findings may be of reference value for future seismic designs of double-row piles.展开更多
This paper describes shaking table tests of three eight-story building models: all are masonry structures in the upper stories, with or without frame-shear walls of one- or two- stories at the bottom. The test result...This paper describes shaking table tests of three eight-story building models: all are masonry structures in the upper stories, with or without frame-shear walls of one- or two- stories at the bottom. The test results of damage characteristics and seismic responses are provided and compared. Then, nonlinear response analyses are conducted to examine the reliability of the dynamic analysis. Finally, many nonlinear response analyses are performed and it is concluded that for relatively hard sites under a certain lateral stiffness ratio (i.e., the ratio of the stiffness of the lowest upper masonry story to that of the frame- shear wall story), the masonry structure with one-story frame-shear wall at the bottom performs better than a structure built entirely of masonry, and a masonry structure with frame-shear wall of two stories performs better than with one-story frame- shear wall. In relatively soft soil conditions, all three structures have similar performane. In addition, some suggestions that could be helpful for design of masonry structures with ground story of frame-shear wall structure in seismic intensity region VII, such as the appropriate lateral stiffness ratio, shear force increase factor of the frame-shear wall story, and permissible maximum height of the building, are proposed.展开更多
Cemented paste backfill(CPB)is extensively used for underground mine support and/or tailings management.However,CPB behavior under cyclic loadings might be affected by the chemistry of its porewater,which often contai...Cemented paste backfill(CPB)is extensively used for underground mine support and/or tailings management.However,CPB behavior under cyclic loadings might be affected by the chemistry of its porewater,which often contains sulphate ions.Till today,no studies have addressed the effect of sulphate on the response of CPB to cyclic loadings by using shaking table technique.This study presents new findings of assessing the effect of the sulphate in the pore water of CPB on its geotechnical response to cyclic loading by using shaking table.CPB mixtures were prepared(with and without sulphate),poured into a flexible laminar shear box,cured to 4 h,and then exposed to cyclic loading using one-dimensional(1D)shaking table.Several parameters(e.g.pore water pressure,settlement,lateral deformation,acceleration,electrical conductivity,effective stress,and liquefaction susceptibility)were monitored or determined before,during,and after shaking.Obtained results indicate that the sulphate-bearing CPB cured to 4 h can be prone to liquefaction under the studied conditions.However,sulphate-free CPB samples are resistant to liquefaction.These results are expected to contribute to a better understanding of the effect of water chemistry on the cyclic behavior of CPB,consequently enhancing the cost-effective design of CPB structures.展开更多
This study addresses the changes in acceleration,pore water pressure and Fourier spectrums of different types of seismic waves with various amplitudes via large-scale shaking table tests from two sites:a sand-containi...This study addresses the changes in acceleration,pore water pressure and Fourier spectrums of different types of seismic waves with various amplitudes via large-scale shaking table tests from two sites:a sand-containing regional site and an all-clay site.Comparative analyses of the test results show that the pore water pressures in sand-soil layers of the regional site initially increase and then decrease as the amplitudes of the seismic accelerations increase.The actions of the vertical and vibrational seismic waves contribute to greater pore water pressures.The amplification coefficient of the sand-layer regional site becomes smaller as the seismic waves grow stronger,so that both sites are capable of filtering high frequencies and amplifying low frequencies of seismic waves.This is more apparent with the increase in the peak value of the acceleration,and the natural vibration frequencies of both sites decrease with the transmission of the seismic waves from the basement to the ground surface.The decreasing frequency value of the sand-containing regional site is smaller than that of the all-clay site.展开更多
As a combined supporting structure,the anchor cable and lattice beam have a complex interaction with the slope body.In order to investigate the seismic behaviors of the slope reinforced by anchor cable and lattice bea...As a combined supporting structure,the anchor cable and lattice beam have a complex interaction with the slope body.In order to investigate the seismic behaviors of the slope reinforced by anchor cable and lattice beam,a largescale shaking table test was carried out on a slope model(geometric scale of 1:20)by applying recorded and artificial seismic waves with different amplitudes.The acceleration and displacement of the slope,the displacement of lattice beam and the axial force of anchor cable were obtained to study the interaction between the slope and the supporting structure.The test results show that:(1)the acceleration responses of the slope at different relative elevations display obvious nonlinear characteristics with increasing of the peak ground acceleration(PGA)of the inputted seismic waves,and the weak intercalated layer has a stronger effect on acceleration amplification at the upper part of the slope than that at the lower part of the slope;(2)the frequency component near the second dominant frequency is significantly magnified by the interaction between the slope and the supporting structure;(3)the anchor cables at the upper part of the slope have larger peak and residual axial forces than that at the lower part of the slope,and the prestress loss of the anchor cable first occurs at the top of the slope and then passes down;(4)the peak and residual displacements inside the slope and on the lattice beam increase with the increase of relative elevation.When the inputted PGA is not greater than 0.5 g,the combined effect of anchor cable and lattice beam is remarkable for stabilizing the middle and lower parts of the potential sliding body.The research results can provide a reference for the seismic design of such slope and the optimization of supporting structure.展开更多
To study the dynamic response of vertical and batter pile groups in saturated sand,dynamic tests of these pile groups in saturated sand were carried out using the ZJU400 geotechnical centrifuge at Zhejiang University....To study the dynamic response of vertical and batter pile groups in saturated sand,dynamic tests of these pile groups in saturated sand were carried out using the ZJU400 geotechnical centrifuge at Zhejiang University.The following results were obtained.(1)As the motion intensity increased,the peak acceleration in soil layers at different depths significantly decreased,indicating that the soil stiffness was significantly reduced.(2)During the motion process,the instantaneous bending moment of the vertical and batter pile groups at different depths changed continuously,which had a strong relationship with the saturated sand liquefaction.In the process of sand liquefaction,the residual bending moment generated by the batter pile was more obvious than that of the vertical pile.(3)With the liquefaction of the saturated sand,the distribution of the maximum bending moment of the vertical pile group changed,and the bending moment near the pile cap of the vertical and batter pile groups was always large.(4)In certain cases,the horizontal acceleration and dynamic displacement of the vertical pile cap were amplified.When the motion intensity was large,residual displacement of the batter pile cap occurred.展开更多
Gravity retaining wall with geogrids has showed excellent seismic performance from Wenchuan great earthquake.However,seismic damage mechanism of this kind of wall is not sufficiently clear.In view of this,a large shak...Gravity retaining wall with geogrids has showed excellent seismic performance from Wenchuan great earthquake.However,seismic damage mechanism of this kind of wall is not sufficiently clear.In view of this,a large shaking table test of the gravity retaining wall with geogrids to reinforce the subgrade slope was carried out,and based on the HilbertHuang transform and the marginal spectrum theory,the energy identification method of the slope dynamic failure mode was studied.The results show that the geogrids can effectively reduce displacement and rotation of the retaining wall,and it can effectively absorb the energy of the ground movement when combined with the surrounding soil.In addition,it also reveals the failure development of the gravity retaining wall with geogrids to reinforce the subgrade slope.The damage started in the deep zone near the geogrids,and then gradually extended to the surface of the subgrade slope and other zones,finally formed a continuous failure surface along the geogrids.The analysis results of the failure mode identified by the Hilbert marginal spectrum are in good consistency with the experimental results,which prove that the Hilbert marginal spectrum can be applied to obtain the seismic damage mechanism of slope.展开更多
Adopting a soft site model built on soft interlayer soil foundation,a shaking table test for soft interlayer soil-isolated structure interaction is conducted to investigate the seismic response of isolated structure o...Adopting a soft site model built on soft interlayer soil foundation,a shaking table test for soft interlayer soil-isolated structure interaction is conducted to investigate the seismic response of isolated structure on soft site,and analyze its isolation effect.Test results show that the test can reflect the earthquake response characteristics of isolated structure on soft site.It is on soft site that the dynamic characteristics of isolated structure,acceleration magnification factor(AMF)of isolated structure and isolation efficiency of the isolation layer differ from those on rigid foundation with an soil-structure interaction(SSI)effect,represented by the reduction in fundamental vibration frequency of isolated structure and the increase of damping ratio with changes of the SSI effect.SSI can either increase or decrease AMF of isolated structure on soft site,depending on the characteristics of earthquake motion input.Furthermore,the isolation efficiency of isolation layer on soft site is decreased with the SSI effect,which is related to the peak ground acceleration(PGA)and the characteristics of earthquake motion input.展开更多
基金Scientific Research Fund of Institute of Engineering Mechanics,China Earthquake Administration under Grant Nos.2021EEEVL0204 and 2018A02。
文摘As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scale reinforced concrete(RC)frame structure.Different material pipes and different methods for penetrating the reinforced concrete floors are combined to evaluate the difference in seismic performance.Floor response spectra and pipe acceleration amplification factors based on test data are discussed and compared with code provisions.A seismic fragility study of displacement demand is conducted based on numerical simulation.The acceleration response and displacement response of different combinations are compared.The results show that the combination of different pipe materials and different passing-through methods can cause obvious differences in the seismic response of indoor riser pipes.
基金National Natural Science Foundation of China under Grant Nos. 52178336 and 52108324Natural Science Research Project of Colleges and Universities in Jiangsu Province of China under Grant No. 18KJA560002+1 种基金the Middle-Aged&Young Science Leaders of Qinglan Project of Universities in Jiangsu Province of ChinaPostgraduate Research&Practice Innovation Program in Jiangsu Province of China under Grant No. KYCX24_1585
文摘The seismic performance of a caisson structure under two types of models with a saturated sandy foundation(CSS)and an expanded polystyrene(EPS)composite soil foundation(CES)are studied using shaking table tests.The macro phenomena of the two different foundation models are described and analyzed.The effects of the replacement of EPS composite soil on seismic-induced liquefaction of backfill and the dynamic performance of a caisson structure are evaluated in detail.The results show that the excess pore water pressure generation in the CES is significantly slower than that in the CSS during the shaking.The dynamic earth pressure acting on the caisson has a triangular shape.The response of horizontal acceleration,displacement,settlement,and rotation angle of the caisson in the CES is smaller than that in the CSS,which means the caisson in the CES has a better seismic performance.Furthermore,the out-of-phase phenomenon between dynamic earth thrust and inertial force in the CES is more obvious than that in the CSS,which is beneficial to reduce the lateral force and improve the stability of the caisson structure.
基金National Natural Science Foundation of China under Grant No.52078020。
文摘When an underground structure passes through a liquefiable soil layer,the soil liquefaction may pose a significant threat to the structure.A centrifuge shaking table test was performed to research the seismic response of underground structures in liquefiable interlayer sites,and a valid numerical model was obtained through simulation model test.Finally,the calibrated numerical model was used to perform further research on the influence of various distribution characteristics of liquefiable interlayers on the seismic reaction of underground structures.The key findings are as follows.The structure faces the most unfavorable condition once a liquefiable layer is located in the middle of the underground structure.When a liquefiable layer exists in the middle of the structure,the seismic reactions of both the underground structure and model site will increase with the rise of the thickness of the liquefiable interlayer.The inter-story drift of the structure in the non-liquefiable site is much smaller than that in the liquefiable interlayer site.The inter-story drift of the structure is not only associated with the site displacement and the soil-structure stiffness ratio but also closely associated with the slippage of the soil-structure contact interface under the condition of large deformation of the site.
基金National Key R&D Program of China,Grant/Award Number:2018YFC1504901Science and technology program of Gansu Province,Grant/Award Numbers:21JR7RA738,21JR7RA739+1 种基金Science and Technology Development Project of China Railway Research Institute Co.Ltd,Grant/Award Number:2017‐KJ008‐Z008‐XBNatural Science Foundation of Gansu Province,Grant/Award Number:145RJZA068。
文摘To explore the cumulative deformation effect of the dynamic response of a tunnel crossing the hauling sliding surface under earthquakes,the shaking table test was conducted in this study.Combined with the numerical calculations,this study proposed magnification of the Arias intensity(MIa)to characterize the overall local deformation damage of the tunnel lining in terms of the deformation characteristics,frequency domain,and energy.Using the time‐domain analysis method,the plastic effect coefficient(PEC)was proposed to characterize the degree of plastic deformation,and the applicability of the seismic cumulative failure effect(SCFE)was discussed.The results show that the low‐frequency component(f1 and f2≤10 Hz)and the high‐frequency component(f3 and f4>10 Hz)acceleration mainly cause global and local deformation of the tunnel lining.The local deformation caused by the high‐frequency wave has an important effect on the seismic damage of the lining.The physical meaning of PEC is more clearly defined than that of the residual strain,and the SCFE of the tunnel lining can also be defined.The SCFE of the tunnel lining includes the elastic deformation effect stage(<0.15g),the elastic–plastic deformation effect stage(0.15g–0.30g),and the plastic deformation effect stage(0.30g–0.40g).This study can provide valuable theoretical and technical support for the construction of traffic tunnels in high‐intensity earthquake areas.
基金Key Project in the National Science & Technology Pillar Program Under Grant No. 2006BAJ03B03Research Fund for Young Teacher Supported by State Key Laboratory for Disaster Reduction in Civil Engineering Under Grant No. SLDRCE08-C-03
文摘Underground utility tunnels are widely used in urban areas throughout the world for lifeline networks due to their easy maintenance and environmental protection capabilities. However, knowledge about their seismic performance is still quite limited and seismic design procedures are not included in current design codes. This paper describes a series of shaking table tests the authors performed on a scaled utility tunnel model to explore its performance under earthquake excitation. Details of the experimental setup are first presented focusing on aspects such as the design of the soil container, scaled structural model, sensor array arrangement and test procedure. The main observations from the test program, including structural response, soil response, soil-structure interaction and earth pressure, are summarized and discussed. Further, a finite element model (FEM) of the test utility tunnel is established where the nonlinear soil properties are modeled by the Drucker- Prager constitutive model; the master-slave surface mechanism is employed to simulate the soil-structure dynamic interaction; and the confining effect of the laminar shear box to soil is considered by proper boundary modeling. The results from the numerical model are compared with experiment measurements in terms of displacement, acceleration and amplification factor of the structural model and the soil. The comparison shows that the numerical results match the experimental measurements quite well. The validated numerical model can be adopted for further analysis.
基金National Natural Science Foundation of China Under Grant No.11172210National Hi-Tech Development Plan(863 Plan)Under Grant No.2008AA05Z413+2 种基金the Fundamental Fund for Central Universitiesthe Shuguang Program of Shanghai Citythe State Key Laboratory of Disaster Reduction in Civil Engineering Under Grant Nos.SLDRCE14-A-06 and SLDRCE14-B-17
文摘A wind turbine system equipped with a tuned liquid column damper (TLCD) is comprehensively studied via shaking table tests using a 1/13-scaled model. The effects of wind and wave actions are considered by inputting response- equivalent accelerations on the shaking table. The test results show that the control effect of the TLCD system is significant in reducing the responses under both wind-wave equivalent loads and ground motions, but obviously varies for different inputs, Further, a blade-hub-tower integrated numerical model for the wind turbine system is established. The model is capable of considering the rotational effect of blades by combining Kane's equation with the finite element method. The responses of the wind tower equipped with TLCD devices are numerically obtained and compared to the test results, showing that under both controlled and uncontrolled conditions with and without blades' rotation, the corresponding responses exhibit good agreement. This demonstrates that the proposed numerical model performs well in capturing the wind-wave coupled response of the offshore wind turbine systems under control. Both numerical and experimental results show that the TLCD system can significantly reduce the structural response and thus improve the safety and serviceability of the offshore wind turbine tower systems. Additional issues that require further study are discussed.
基金Project(51674287)supported by the National Natural Science Foundation of China。
文摘Mountain tunnel crossing a normal fault in seismically active zone is easily affected by normal fault slip and earthquake. It is necessary to study tunnel dynamic response under action of normal fault slip and earthquake. In this paper, a three-dimensional normal fault sliding device was designed, and a shaking table test was carried out to study tunnel seismic performance under normal fault slip. The results show that peak acceleration of lining is dominated by an existence of fault and direction of seismic excitation, not normal fault slip. And the incremental strains of lining in critical zone with 1.7 times fault thickness and centered in faults induced by normal fault slip and seismic excitation are larger than ones only by seismic excitation. And the incremental strains in critical zone increase with the increase of normal fault slip magnitude ranging from 0 to 2 mm. And normal fault slip results in a significant reduction of overall tunnel stiffness subjected to an earthquake. These experimental results provide a scientific reference for prevention and control measurement of tunnel damage under earthquake and normal fault slip.
基金financially supported by the National Basic Research Program "973" Project of the Ministry of Science and Technology of the People’s Republic of China (Grant No. 2013CB733200)the National Science Found for Distinguished Young Scholars of China (Grant No. 41225011)the Chang Jiang Scholars Program of China and the open fund on "Research on largescale landslides triggered by the Wenchuan earthquake" provided by the State Key Laboratory of Geohazard Prevention and Geoenvironment Protection
文摘Studies on landslides by the 2008 Wenchuan earthquake showed that topography was of great importance in amplifying the seismic shaking, and among other factors, lithology and slope structure controlled the spatial occurrence of slope failures. The present study carried out experiments on four rock slopes with steep angle of 60° by means of a shaking table. The recorded Wenchuan earthquake waves were scaled to excite the model slopes. Measurements from accelerometers installed on free surface of the model slope were analyzed, with much effort on timedomain acceleration responses to horizontal components of seismic shaking. It was found that the amplification factor of peak horizontal acceleration, RPHA, was increasing with elevation of each model slope, though the upper and lower halves of the slope exhibited different increasing patterns. As excitation intensity was increased, the drastic deterioration of the inner structure of each slope caused the sudden increase of RPHA in the upper slope part. In addition, the model simulating the soft rock slope produced the larger RPHA than the model simulating the hard rock slope by a maximum factor of 2.6. The layered model slope also produced the larger RPHA than the homogeneous model slope by a maximum factor of 2.7. The upper half of a slope was influenced more seriously by the effect of lithology, while the lower half was influenced more seriously by the effect of slope structure.
文摘A series of scaled-model shaking table tests and its simulation analyses using dynamic finite element method were performed to clarify the dynamic behaviors and the seismic stability of embedded corrugated steel culverts due to strong earth-quakes like the 1995 Hyogoken-nanbu earthquake. The dynamic strains of the embedded culvert models and the seismic soil pressure acting on the models due to sinusoidal and random strong motions were investigated. This study verified that the cor-rugated culvert model was subjected to dynamic horizontal forces (lateral seismic soil pressure) from the surrounding ground, which caused the large bending strains on the structure; and that the structures do not exceed the allowable plastic deformation and do not collapse completely during strong earthquake like Hyogoken-nanbu earthquake. The results obtained are useful for design and construction of embedded long span corrugated steel culverts in seismic regions.
基金National Science and Technology Support Program of China under Grant No.2011BAJ08B02Natural Science Foundation of Beijing under Grant No.8132016Beijing City University Youth Backbone Talent Training Project under Grant No.PHR201108009
文摘In this study, four 1/5 scaled shaking table tests were conducted to investigate the seismic performance of recycled concrete frame-shear wall structures with different recycled aggregates replacement rates and concealed bracing detail. The four tested structures included one normal concrete model, one recycled coarse aggregate concrete model, and two recycled coarse and fi ne aggregate concrete models with or without concealed bracings inside the shear walls. The dynamic characteristics, dynamic response and failure mode of each model were compared and analyzed. Finite element models were also developed and nonlinear time-history response analysis was conducted. The test and analysis results show that the seismic performance of the recycled coarse aggregate concrete frame-shear wall structure is slightly worse than the normal concrete structure. The seismic resistance capacity of the recycled concrete frame-shear wall structure can be greatly improved by setting up concealed bracings inside the walls. With appropriate design, the recycled coarse aggregate concrete frame-shear wall structure and recycled concrete structure with concealed bracings inside the walls can be applied in buildings.
基金National Key Research and Invention Program of The Thirteenth under Grant Nos.2016YFC0802407,2018YFC0809605。
文摘Underground utility tunnels are the most fundamental and reliable lifeline network in urban cities,and are widely constructed throughout the world.In urban areas,most utility tunnels usually encounter the non-homogeneity of subsoil condition due to various construction effects.Studies have shown that the damage mechanism of shallow underground structures mainly depends on the inhomogeneity of the subsoil conditions.This would become a considerable factor for the stability of the underground utility tunnel structures.However,this type of research still needs to establish the vulnerable seismic design.In this study,a series of shaking table tests were conducted on non-homogenous soils to investigate the performance of seismic interaction between utility tunnels,surrounding soils and interior pipelines.The dynamic responses measured from the test account for the boundary condition of non-homogeneous soils,the internal forces,displacement of tunnel joints,the dynamic characteristics on interior pipelines and the reasonable spring stiffness with damping in the seismically isolated gas pipeline model inside the tunnel.The vulnerability of underground utility tunnel in non-homogeneous soil zone and the mechanism of the stability of interior facilities are the main topics discussed in this paper.
基金Northeast Electric Power Design Institute of China Under Grant No.K07-T716
文摘This paper describes shaking table tests of a 1:12 scale model of a special concentrically braced steel frame with pinned connections, which was fabricated according to a one-bay braced frame selected from a typical main factory building of a large thermal power plant. In order to investigate the seismic performance of this type of structure, several ground motion accelerations with different levels for seismic intensity Ⅷ, based on the Chinese Code for Seismic Design of Buildings, were selected to excite the model. The results show that the design methods of the members and the connections are adequate and that the structural system will perform well in regions of high seismicity. In addition to the tests, numerical simulations were also conducted and the results showed good agreement with the test results. Thus, the numerical model is shown to be accurate and the beam element can be used to model this structural system.
基金the financial support by the National Key R&D Program of China(No.2018YFC1504901)Gansu Province Youth Science and Technology Fund program,China(Grant No.21JR7RA739)+1 种基金Natural Science Foundation of Gansu Province,China(Grant No.21JR7RA738)Natural Science Foundation of Gansu Province,China(No.145RJZA068)。
文摘Despite the continuous advancements of engineering construction in high-intensity areas,many engineering landslides are still manufactured with huge thrust force,and double-row piles are effective to control such large landslides.In this study,large shaking table test were performed to test and obtain multi-attribute seismic data such as feature image,acceleration,and dynamic soil pressure.Through the feature image processing analysis,the deformation characteristics for the slope reinforced by double-row piles were revealed.By analyzing the acceleration and the dynamic soil pressure time domain,the spatial dynamic response characteristics were revealed.Using Fast Fourier Transform and half-power bandwidth,the damping ratio of acceleration and dynamic soil pressure was obtained.Following that,the Seism Signal was used to calculate the spectral displacement of the accelerations to obtain the regional differences of spectral displacement.The results showed that the overall deformation mechanism of the slope originates from tension failure in the soil mass.The platform at the back of the slope was caused by seismic subsidence,and the peak acceleration ratio was positively correlated with the relative pile heights.The dynamic soil pressure of the front row piles showed an inverted"K"-shaped distribution,but that of the back row piles showed an"S"-shaped distribution.The predominant frequency of acceleration was 2.16 Hz,and the main frequency band was 0.7-6.87 Hz;for dynamic soil pressure,the two parameters became 1.15 Hz and 0.5-6.59 Hz,respectively.In conclusion,dynamic soil pressure was more sensitive to dampening effects than acceleration.Besides,compared to acceleration,dynamic soil pressure exhibited larger loss factors and lower resonance peaks.Finally,back row pile heads were highly sensitive to spectral displacement compared to front row pile heads.These findings may be of reference value for future seismic designs of double-row piles.
基金China Joint Earthquake Science Foundation Under Grant No. 95034National Science Foundation of China Under Grant No. 5067816
文摘This paper describes shaking table tests of three eight-story building models: all are masonry structures in the upper stories, with or without frame-shear walls of one- or two- stories at the bottom. The test results of damage characteristics and seismic responses are provided and compared. Then, nonlinear response analyses are conducted to examine the reliability of the dynamic analysis. Finally, many nonlinear response analyses are performed and it is concluded that for relatively hard sites under a certain lateral stiffness ratio (i.e., the ratio of the stiffness of the lowest upper masonry story to that of the frame- shear wall story), the masonry structure with one-story frame-shear wall at the bottom performs better than a structure built entirely of masonry, and a masonry structure with frame-shear wall of two stories performs better than with one-story frame- shear wall. In relatively soft soil conditions, all three structures have similar performane. In addition, some suggestions that could be helpful for design of masonry structures with ground story of frame-shear wall structure in seismic intensity region VII, such as the appropriate lateral stiffness ratio, shear force increase factor of the frame-shear wall story, and permissible maximum height of the building, are proposed.
基金The authors would like to thank the National Natural Sciences and Engineering Research Council of Canada(NSERC)for financially supporting this project
文摘Cemented paste backfill(CPB)is extensively used for underground mine support and/or tailings management.However,CPB behavior under cyclic loadings might be affected by the chemistry of its porewater,which often contains sulphate ions.Till today,no studies have addressed the effect of sulphate on the response of CPB to cyclic loadings by using shaking table technique.This study presents new findings of assessing the effect of the sulphate in the pore water of CPB on its geotechnical response to cyclic loading by using shaking table.CPB mixtures were prepared(with and without sulphate),poured into a flexible laminar shear box,cured to 4 h,and then exposed to cyclic loading using one-dimensional(1D)shaking table.Several parameters(e.g.pore water pressure,settlement,lateral deformation,acceleration,electrical conductivity,effective stress,and liquefaction susceptibility)were monitored or determined before,during,and after shaking.Obtained results indicate that the sulphate-bearing CPB cured to 4 h can be prone to liquefaction under the studied conditions.However,sulphate-free CPB samples are resistant to liquefaction.These results are expected to contribute to a better understanding of the effect of water chemistry on the cyclic behavior of CPB,consequently enhancing the cost-effective design of CPB structures.
基金National Program on Key Basic Research Project(973 Program)under Grant No.2011CB013606Program for Changjiang Scholars and Innovative Research Team in University under Grant No.IRT13057+1 种基金Key Program of National Natural Science Foundation of China under Grant No.51438004the Research Fund for the Doctoral Program of Higher Education of China under Grant No.20124410110004
文摘This study addresses the changes in acceleration,pore water pressure and Fourier spectrums of different types of seismic waves with various amplitudes via large-scale shaking table tests from two sites:a sand-containing regional site and an all-clay site.Comparative analyses of the test results show that the pore water pressures in sand-soil layers of the regional site initially increase and then decrease as the amplitudes of the seismic accelerations increase.The actions of the vertical and vibrational seismic waves contribute to greater pore water pressures.The amplification coefficient of the sand-layer regional site becomes smaller as the seismic waves grow stronger,so that both sites are capable of filtering high frequencies and amplifying low frequencies of seismic waves.This is more apparent with the increase in the peak value of the acceleration,and the natural vibration frequencies of both sites decrease with the transmission of the seismic waves from the basement to the ground surface.The decreasing frequency value of the sand-containing regional site is smaller than that of the all-clay site.
基金National Key R&D Program of China(Grant No.2017YFC0504901)the Science and Technology Plan Projects of Sichuan Province(Grant No 2015SZ0068)
文摘As a combined supporting structure,the anchor cable and lattice beam have a complex interaction with the slope body.In order to investigate the seismic behaviors of the slope reinforced by anchor cable and lattice beam,a largescale shaking table test was carried out on a slope model(geometric scale of 1:20)by applying recorded and artificial seismic waves with different amplitudes.The acceleration and displacement of the slope,the displacement of lattice beam and the axial force of anchor cable were obtained to study the interaction between the slope and the supporting structure.The test results show that:(1)the acceleration responses of the slope at different relative elevations display obvious nonlinear characteristics with increasing of the peak ground acceleration(PGA)of the inputted seismic waves,and the weak intercalated layer has a stronger effect on acceleration amplification at the upper part of the slope than that at the lower part of the slope;(2)the frequency component near the second dominant frequency is significantly magnified by the interaction between the slope and the supporting structure;(3)the anchor cables at the upper part of the slope have larger peak and residual axial forces than that at the lower part of the slope,and the prestress loss of the anchor cable first occurs at the top of the slope and then passes down;(4)the peak and residual displacements inside the slope and on the lattice beam increase with the increase of relative elevation.When the inputted PGA is not greater than 0.5 g,the combined effect of anchor cable and lattice beam is remarkable for stabilizing the middle and lower parts of the potential sliding body.The research results can provide a reference for the seismic design of such slope and the optimization of supporting structure.
基金National Natural Science Foundation of China under Grant No.51778207,Natural Science Foundation of Hebei Province under Grant No.E2018202107,Project of Graduate Students′Innovative Ability Training of Hebei Province under Grant No.CXZZBS2019041。
文摘To study the dynamic response of vertical and batter pile groups in saturated sand,dynamic tests of these pile groups in saturated sand were carried out using the ZJU400 geotechnical centrifuge at Zhejiang University.The following results were obtained.(1)As the motion intensity increased,the peak acceleration in soil layers at different depths significantly decreased,indicating that the soil stiffness was significantly reduced.(2)During the motion process,the instantaneous bending moment of the vertical and batter pile groups at different depths changed continuously,which had a strong relationship with the saturated sand liquefaction.In the process of sand liquefaction,the residual bending moment generated by the batter pile was more obvious than that of the vertical pile.(3)With the liquefaction of the saturated sand,the distribution of the maximum bending moment of the vertical pile group changed,and the bending moment near the pile cap of the vertical and batter pile groups was always large.(4)In certain cases,the horizontal acceleration and dynamic displacement of the vertical pile cap were amplified.When the motion intensity was large,residual displacement of the batter pile cap occurred.
基金Supported by:Strategic International Science and Technology Innovation Cooperation Project from National Key R&D Program of China under Grant No.2018YFE0207100the National Natural Science Foundation of China under Grant No.41602332。
文摘Gravity retaining wall with geogrids has showed excellent seismic performance from Wenchuan great earthquake.However,seismic damage mechanism of this kind of wall is not sufficiently clear.In view of this,a large shaking table test of the gravity retaining wall with geogrids to reinforce the subgrade slope was carried out,and based on the HilbertHuang transform and the marginal spectrum theory,the energy identification method of the slope dynamic failure mode was studied.The results show that the geogrids can effectively reduce displacement and rotation of the retaining wall,and it can effectively absorb the energy of the ground movement when combined with the surrounding soil.In addition,it also reveals the failure development of the gravity retaining wall with geogrids to reinforce the subgrade slope.The damage started in the deep zone near the geogrids,and then gradually extended to the surface of the subgrade slope and other zones,finally formed a continuous failure surface along the geogrids.The analysis results of the failure mode identified by the Hilbert marginal spectrum are in good consistency with the experimental results,which prove that the Hilbert marginal spectrum can be applied to obtain the seismic damage mechanism of slope.
基金supported by the Jiangsu Natural Science Foundation of China(Grant No.BK2012477)the Science Research Foundation of Nanjing Institute of Technology(CKJA201505,JCYJ201618)
文摘Adopting a soft site model built on soft interlayer soil foundation,a shaking table test for soft interlayer soil-isolated structure interaction is conducted to investigate the seismic response of isolated structure on soft site,and analyze its isolation effect.Test results show that the test can reflect the earthquake response characteristics of isolated structure on soft site.It is on soft site that the dynamic characteristics of isolated structure,acceleration magnification factor(AMF)of isolated structure and isolation efficiency of the isolation layer differ from those on rigid foundation with an soil-structure interaction(SSI)effect,represented by the reduction in fundamental vibration frequency of isolated structure and the increase of damping ratio with changes of the SSI effect.SSI can either increase or decrease AMF of isolated structure on soft site,depending on the characteristics of earthquake motion input.Furthermore,the isolation efficiency of isolation layer on soft site is decreased with the SSI effect,which is related to the peak ground acceleration(PGA)and the characteristics of earthquake motion input.